CVC-TM SERIES THREE PHASE 6KVA ~ 1000KVA
Installations with long cable runs have an inherent problem of developing high voltage drop across their cables. To overcome this, it is necessary to select and use larger sized electrical cables in order to reduce such voltage drop to an acceptable level. IEE Regulations stipulate that a volt drop should be no more than 4% which means that for a 3 phase 400V system, the drop across any length of cable shall not exceed 16 Volts. Therefore design engineers have to use larger cable size to cater for this drop. However, they also have to take the mains supply voltage fluctuations into consideration. Typically mains fluctuations is expected to be +/-6%. This means the engineer has to cater to wider voltage drop than necessary, leading to a larger size cable and this can be a very costly affair. Our Ashley-Edison’s Indoor Constant Voltage Compensators have been carefully designed with this application in mind. The New Parallel Redundant Voltage Regulation Control Module (VRCM) is incorporated on each phase of the Compensator. Should one Module fail or malfunction, the other parallel Module will operate automatically without causing interruption to the load and also without affecting capacity. The other phases not affected will still operate as normal. This will ensure that the voltage control is regulated continuously. This feature is especially useful for critical load application. Downtime is minimized. With the Compensator installed at the end of the cable line:
• • • •
This Voltage Drop problem will be resolved - voltage will be ‘compensated’ / boosted up to the required voltage. End voltage will be kept constant all the time, automatically, from no-load to full-load. Load change will not have any effect on this voltage - with the compensator installed, this voltage is kept constant continuously, automatically. Cable sizing is therefore reduced to a more affordable level. Cable installation is made more convenient due to smaller cable size.
New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime.
Utilizing Advanced Digital Controller
HUGE SAVINGS with Ashley-Edison’s Constant Voltage Compensators
Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost
Models: High Voltage (H) Models 380/220V; 400/230V or 415/240V (Three Phase)
Features:
• •
Low Voltage (L) Models 200/115V; 208/120V or 220/127V (Three Phase)
• • • •
CVC-TM/MAY/2009/5
Wide Range of Constant Voltage Compensator Three Phase Up to 1000KVA Input Voltage Range available from : (S1) 373V ~ 430V (S2) 352V ~ 430V (S3) 332V ~ 430V (S4) 311V ~ 430V (S5) 290V ~ 430V (To Specify) Output Voltage Regulation Output Voltage Accuracy ± 1%, High Efficiency Better than 98% Independent Phase Control Circuit Sensing on all Individual Three Phases Standard Protection Features Input circuit breaker Bypass control switch Over/low voltage protection Phase-failure protection Voltmeter / Selector switch ( Internal)
•
•
• •
Optional Accessories Output circuit breaker Ammeter / Selector switch Frequency meter Manual maintenance bypass switch Lightning arrester Compliance with International Standards BS EN50081-1;2/IEC 61000-4-3;4 BS EN5490/IEC 60529 CE Conformity EN55022,EN50082-2,ENV50140-1 Warranty 2 Years
Applications • Communication Systems
• •
• • • •
TV/Radio Broadcasting Stations Security Systems Communication Stations Lighting Systems Golf Course Lighting Systems Perimeter Lighting
www.AshleyEdison.com
CVC-H-S1-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage
373V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V
Output Voltage Accuracy
± 1%
Frequency
47 – 65 Hz
Response Time
<1.5ms
Correction Time
A 10% supply variation will be corrected to within 2.5% in 0.6 seconds
Efficiency
98%
Power Factor
Any lagging to 0.95 leading
Surge ratings
10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes
Surge Suppression
Protect loads against high-energy spikes and transient voltage.
Total Harmonic Distortion
<1%
Independent Phase Control
Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance
Soft Switch-ON
Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization
Parallel Redundancy Module
Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity
Environment
Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m
Standard Features
Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal)
Construction
Enclosures to IP20, BS EN5490 / IEC 60529
EMC Conformance
BS EN50081-1;2 / IEC 61000-4-3;4
CE Conformity
EN55022, EN50082-2,ENV50140-1
Optional Accessories
Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch
Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order
New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime.
Utilizing Advanced Digital Controller
Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost
Three Phase Model: CVC-H-3P-S1-TM Model:
Dimensions (mm) WxHxD
Weight (Kgs)
8.3
380 x 1240 x 780
190
Rating Amps Amps Amps KVA @ 380V @ 400V @ 415V
CVC 6H-3P-S1-TM
6
9.1
8.7
CVC 10H-3P-S1-TM CVC 15H-3P-S1-TM
10
15.2
14.4.
13.9
380 x 1240 x 780
194
15
22.8
21.6
20.9
380 x 1240 x 780
197
CVC 20H-3P-S1-TM
20
30.4
28.9
27.8
380 x 1240 x 780
200
CVC 25H-3P-S1-TM
25
38
36.1
35
380 x 1240 x 780
200
CVC 30H-3P-S1-TM
30
46
43
42
380 x 1240 x 780
203
CVC 35H-3P-S1-TM
35
53
51
49
380 x 1240 x 780
200
CVC 40H-3P-S1-TM
40
61
58
56
380 x 1240 x 780
205
CVC 45H-3P-S1-TM
45
68
65
63
380 x 1240 x 780
209
CVC 50H-3P-S1-TM
50
76
72
70
380 x 1240 x 780
211
CVC 55H-3P-S1-TM
55
84
79
77
380 x 1240 x 780
213
CVC 60H-3P-S1-TM
60
91
87
83
380 x 1240 x 780
215
CVC 75H-3P-S1-TM
75
114
108
104
1000 x 1300 x 580
311
CVC 80H-3P-S1-TM
80
122
115
111
1000 x 1300 x 580
334
CVC 90H-3P-S1-TM
90
137
130
125
1000 x 1300 x 580
336
CVC 100H-3P-S1-TM
100
152
144
139
1000 x 1300 x 580
338
CVC 120H-3P-S1-TM
120
182
173
167
1000 x 1300 x 580
361
CVC 150H-3P-S1-TM
150
228
216
209
1280 x 1380 x 660
549
CVC 180H-3P-S1-TM
180
273
260
250
1280 x 1380 x 660
570
CVC 200H-3P-S1-TM
200
304
289
278
1280 x 1380 x 660
573
CVC 250H-3P-S1-TM
250
380
361
348
1280 x 1380 x 660
576
CVC 300H-3P-S1-TM
300
456
433
417
1280 x 1380 x 660
609
CVC 350H-3P-S1-TM
350
532
505
487
1280 x 1950 x 820
780
CVC 400H-3P-S1-TM
400
608
577
556
1280 x 1950 x 820
790
CVC450H-3P-S1-TM
450
684
649
626
1280 x 1950 x 820
970
CVC 500H-3P-S1-TM
500
760
722
695
1280 x 1950 x 820
980
Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice.
CVC-3P-S1-TM/MAY/2009/5
www.AshleyEdison.com
CVC-H-S2-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage
352V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V
Soft Switch-ON
Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization
Parallel Redundancy Module
Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity
Environment
Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m
Standard Features
Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal)
Output Voltage Accuracy
± 1%
Frequency
47 – 65 Hz
Response Time
<1.5ms
Correction Time
A 10% supply variation will be corrected to within 2.5% in 0.6 seconds
Efficiency
98%
Power Factor
Any lagging to 0.95 leading
Surge ratings
10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes
Construction
Enclosures to IP20, BS EN5490 / IEC 60529
EMC Conformance
BS EN50081-1;2 / IEC 61000-4-3;4
Surge Suppression
Protect loads against high-energy spikes and transient voltage.
CE Conformity
EN55022, EN50082-2,ENV50140-1
Total Harmonic Distortion
<1%
Optional Accessories
Independent Phase Control
Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance
Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch
Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order
New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime.
Utilizing Advanced Digital Controller
Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost
Three Phase Model: CVC-H-3P-S2-TM Model:
Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD
Weight (Kgs)
CVC 6H-3P-S2-TM
6
9.1
8.7
8.3
380 x 1240 x 780
190
CVC 10H-3P-S2-TM
10
15.2
14.4.
13.9
380 x 1240 x 780
194
CVC 15H-3P-S2-TM
15
22.8
21.6
20.9
380 x 1240 x 780
197
CVC 20H-3P-S2-TM
20
30.4
28.9
27.8
380 x 1240 x 780
200
CVC 25H-3P-S2-TM
25
38
36.1
35
380 x 1240 x 780
200
CVC 30H-3P-S2-TM
30
46
43
42
380 x 1240 x 780
203
CVC 35H-3P-S2-TM
35
53
51
49
380 x 1240 x 780
200
CVC 40H-3P-S2-TM
40
61
58
56
380 x 1240 x 780
205
CVC 45H-3P-S2-TM
45
68
65
63
380 x 1240 x 780
209
CVC 50H-3P-S2-TM
50
76
72
70
380 x 1240 x 780
211
CVC 55H-3P-S2-TM
55
84
79
77
380 x 1240 x 780
213
CVC 60H-3P-S2-TM
60
91
87
83
380 x 1240 x 780
215
CVC 75H-3P-S2-TM
75
114
108
104
1000 x 1300 x 580
311
CVC 80H-3P-S2-TM
80
122
115
111
1000 x 1300 x 580
334
CVC 90H-3P-S2-TM
90
137
130
125
1000 x 1300 x 580
336
CVC 100H-3P-S2-TM
100
152
144
139
1000 x 1300 x 580
338
CVC 120H-3P-S2-TM
120
182
173
167
1000 x 1300 x 580
361
CVC 150H-3P-S2-TM
150
228
216
209
1280 x 1380 x 660
549
CVC 180H-3P-S2-TM
180
273
260
250
1280 x 1380 x 660
570
CVC 200H-3P-S2-TM
200
304
289
278
1280 x 1950 x 820
706
CVC 250H-3P-S2-TM
250
380
361
348
1280 x 1950 x 820
766
CVC 300H-3P-S2-TM
300
456
433
417
1280 x 1950 x 820
946
CVC 350H-3P-S2-TM
350
532
505
487
1280 x 1950 x 820
1030
CVC 400H-3P-S2-TM
400
608
577
556
1280 x 1950 x 820
1041
CVC450H-3P-S2-TM
450
684
649
626
1280 x 1950 x 820
1210
CVC 500H-3P-S2-TM
500
760
722
695
1280 x 1950 x 820
1227
Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice.
CVC-3P-S2-TM/MAY/2009/5
www.AshleyEdison.com
CVC-H-S3-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage
332V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V
Output Voltage Accuracy
± 1%
Frequency
47 – 65 Hz
Response Time
<1.5ms
Correction Time
A 10% supply variation will be corrected to within 2.5% in 0.6 seconds
Efficiency
98%
Power Factor
Any lagging to 0.95 leading
Surge ratings
10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes
Surge Suppression
Protect loads against high-energy spikes and transient voltage.
Total Harmonic Distortion
<1%
Independent Phase Control
Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance
Soft Switch-ON
Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization
Parallel Redundancy Module
Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity
Environment
Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m
Standard Features
Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal)
Construction
Enclosures to IP20, BS EN5490 / IEC 60529
EMC Conformance
BS EN50081-1;2 / IEC 61000-4-3;4
CE Conformity
EN55022, EN50082-2,ENV50140-1
Optional Accessories
Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch
Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order
New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime.
Utilizing Advanced Digital Controller
Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost
Three Phase Model: CVC-H-3P-S3-TM Model:
Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD
Weight (Kgs)
CVC 6H-3P-S3-TM
6
9.1
8.7
8.3
380 x 1240 x 780
198
CVC 10H-3P-S3-TM
10
15.2
14.4.
13.9
380 x 1240 x 780
200
CVC 15H-3P-S3-TM
15
22.8
21.6
20.9
380 x 1240 x 780
203
CVC 20H-3P-S3-TM
20
30.4
28.9
27.8
380 x 1240 x 780
206
CVC 25H-3P-S3-TM
25
38
36.1
35
380 x 1240 x 780
208
CVC 30H-3P-S3-TM
30
46
43
42
380 x 1240 x 780
209
CVC 35H-3P-S3-TM
35
53
51
49
380 x 1240 x 780
211
CVC 40H-3P-S3-TM
40
61
58
56
380 x 1240 x 780
213
CVC 45H-3P-S3-TM
45
68
65
63
380 x 1240 x 780
215
CVC 50H-3P-S3-TM
50
76
72
70
1000 x 1300 x 580
310
CVC 55H-3P-S3-TM
55
84
79
77
1000 x 1300 x 580
317
CVC 60H-3P-S3-TM
60
91
87
83
1000 x 1300 x 580
320
CVC 75H-3P-S3-TM
75
114
108
104
1000 x 1300 x 580
339
CVC 80H-3P-S3-TM
80
122
115
111
1000 x 1300 x 580
365
CVC 90H-3P-S3-TM
90
137
130
125
1000 x 1300 x 580
370
CVC 100H-3P-S3-TM
100
152
144
139
1000 x 1300 x 580
375
CVC 120H-3P-S3-TM
120
182
173
167
1280 x 1380 x 660
546
CVC 150H-3P-S3-TM
150
228
216
209
1280 x 1950 x 820
700
CVC 180H-3P-S3-TM
180
273
260
250
1280 x 1950 x 820
763
CVC 200H-3P-S3-TM
200
304
289
278
1280 x 1950 x 820
821
CVC 250H-3P-S3-TM
250
380
361
348
1280 x 1950 x 820
950
CVC 300H-3P-S3-TM
300
456
433
417
1280 x 1950 x 820
1152
CVC 350H-3P-S3-TM
350
532
505
487
1280 x 1950 x 820
1200
CVC 400H-3P-S3-TM
400
608
577
556
1280 x 1950 x 820
1217
CVC450H-3P-S3-TM
450
684
649
626
1280 x 1950 x 1200
1600
CVC 500H-3P-S3-TM
500
760
722
695
1280 x 1950 x 1200
1629
Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice.
CVC-3P-S3-TM/MAY/2009/5
www.AshleyEdison.com
CVC-H-S4-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage
311V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V
Output Voltage Accuracy
± 1%
Frequency
47 – 65 Hz
Response Time
<1.5ms
Correction Time
A 10% supply variation will be corrected to within 2.5% in 0.6 seconds
Efficiency
98%
Power Factor
Any lagging to 0.95 leading
Surge ratings
10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes
Surge Suppression
Protect loads against high-energy spikes and transient voltage.
Total Harmonic Distortion
<1%
Independent Phase Control
Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance
Soft Switch-ON
Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization
Parallel Redundancy Module
Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity
Environment
Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m
Standard Features
Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal)
Construction
Enclosures to IP20, BS EN5490 / IEC 60529
EMC Conformance
BS EN50081-1;2 / IEC 61000-4-3;4
CE Conformity
EN55022, EN50082-2,ENV50140-1
Optional Accessories
Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch
Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order
New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime.
Utilizing Advanced Digital Controller
Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost
Three Phase Model: CVC-H-3P-S4-TM Model:
Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD
Weight (Kgs)
CVC 6H-3P-S4-TM
6
9.1
8.7
8.3
380 x 1240 x 780
200
CVC 10H-3P-S4-TM
10
15.2
14.4.
13.9
380 x 1240 x 780
203
CVC 15H-3P-S4-TM
15
22.8
21.6
20.9
380 x 1240 x 780
206
CVC 20H-3P-S4-TM
20
30.4
28.9
27.8
380 x 1240 x 780
209
CVC 25H-3P-S4-TM
25
38
36.1
35
380 x 1240 x 780
212
CVC 30H-3P-S4-TM
30
46
43
42
380 x 1240 x 780
215
CVC 35H-3P-S4-TM
35
53
51
49
1000 x 1300 x 580
310
CVC 40H-3P-S4-TM
40
61
58
56
1000 x 1300 x 580
315
CVC 45H-3P-S4-TM
45
68
65
63
1000 x 1300 x 580
320
CVC 50H-3P-S4-TM
50
76
72
70
1000 x 1300 x 580
332
CVC 55H-3P-S4-TM
55
84
79
77
1000 x 1300 x 580
337
CVC 60H-3P-S4-TM
60
91
87
83
1000 x 1300 x 580
342
CVC 75H-3P-S4-TM
75
114
108
104
1280 x 1380 x 660
542
CVC 80H-3P-S4-TM
80
122
115
111
1280 x 1950 x 820
679
CVC 90H-3P-S4-TM
90
137
130
125
1280 x 1950 x 820
689
CVC 100H-3P-S4-TM
100
152
144
139
1280 x 1950 x 820
699
CVC 120H-3P-S4-TM
120
182
173
167
1280 x 1950 x 820
752
CVC 150H-3P-S4-TM
150
228
216
209
1280 x 1950 x 820
841
CVC 180H-3P-S4-TM
180
273
260
250
1280 x 1950 x 820
985
CVC 200H-3P-S4-TM
200
304
289
278
1280 x 1950 x 820
1005
CVC 250H-3P-S4-TM
250
380
361
348
1280 x 1950 x 820
1179
CVC 300H-3P-S4-TM
300
456
433
417
1280 x 1950 x 820
1219
CVC 350H-3P-S4-TM
350
532
505
487
1280 x 1950 x 1200
1690
CVC 400H-3P-S4-TM
400
608
577
556
1280 x 1950 x 1200
1709
CVC450H-3P-S4-TM
450
684
649
626
1280 x 1950 x 1200
1750
CVC 500H-3P-S4-TM
500
760
722
695
1280 x 1950 x 1200
1770
Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice.
CVC-3P-S4-TM/MAY/2009/5
www.AshleyEdison.com
CVC-H-S5-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage
290V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V
Output Voltage Accuracy
± 1%
Frequency
47 – 65 Hz
Response Time
<1.5ms
Correction Time
A 10% supply variation will be corrected to within 2.5% in 0.6 seconds
Efficiency
98%
Power Factor
Any lagging to 0.95 leading
Surge ratings
10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes
Surge Suppression
Protect loads against high-energy spikes and transient voltage.
Total Harmonic Distortion
<1%
Independent Phase Control
Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance
Soft Switch-ON
Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization
Parallel Redundancy Module
Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity
Environment
Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m
Standard Features
Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal)
Construction
Enclosures to IP20, BS EN5490 / IEC 60529
EMC Conformance
BS EN50081-1;2 / IEC 61000-4-3;4
CE Conformity
EN55022, EN50082-2,ENV50140-1
Optional Accessories
Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch
Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order
New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime.
Utilizing Advanced Digital Controller
Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost
Three Phase Model: CVC-H-3P-S5-TM Model:
Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD
Weight (Kgs)
CVC 6H-3P-S5-TM
6
9.1
8.7
8.3
380 x 1240 x 780
204
CVC 10H-3P-S5-TM
10
15.2
14.4.
13.9
380 x 1240 x 780
206
CVC 15H-3P-S5-TM
15
22.8
21.6
20.9
380 x 1240 x 780
209
CVC 20H-3P-S5-TM
20
30.4
28.9
27.8
380 x 1240 x 780
215
CVC 25H-3P-S5-TM
25
38
36.1
35
1000 x 1300 x 580
317
CVC 30H-3P-S5-TM
30
46
43
42
1000 x 1300 x 580
320
CVC 35H-3P-S5-TM
35
53
51
49
1000 x 1300 x 580
332
CVC 40H-3P-S5-TM
40
61
58
56
1000 x 1300 x 580
335
CVC 45H-3P-S5-TM
45
68
65
63
1000 x 1300 x 580
338
CVC 50H-3P-S5-TM
50
76
72
70
1280 x 1380 x 660
534
CVC 55H-3P-S5-TM
55
84
79
77
1280 x 1380 x 660
537
CVC 60H-3P-S5-TM
60
91
87
83
1280 x 1380 x 660
540
CVC 75H-3P-S5-TM
75
114
108
104
1280 x 1950 x 820
673
CVC 80H-3P-S5-TM
80
122
115
111
1280 x 1950 x 820
744
CVC 90H-3P-S5-TM
90
137
130
125
1280 x 1950 x 820
748
CVC 100H-3P-S5-TM
100
152
144
139
1280 x 1950 x 820
752
CVC 120H-3P-S5-TM
120
182
173
167
1280 x 1950 x 820
844
CVC 150H-3P-S5-TM
150
228
216
209
1280 x 1950 x 820
978
CVC 180H-3P-S5-TM
180
273
260
250
1280 x 1950 x 820
1134
CVC 200H-3P-S5-TM
200
304
289
278
1280 x 1950 x 820
1192
CVC 250H-3P-S5-TM
250
380
361
348
1280 x 1950 x 820
1320
CVC 300H-3P-S5-TM
300
456
433
417
1280 x 1950 x 1200
1600
CVC 350H-3P-S5-TM
350
532
505
487
1280 x 1950 x 1200
1800
CVC 400H-3P-S5-TM
400
608
577
556
1280 x 1950 x 1200
1820
CVC450H-3P-S5-TM
450
684
649
626
1280 x 1950 x 1200
2400
CVC 500H-3P-S5-TM
500
760
722
695
1280 x 1950 x 1200
2425
Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice.
CVC-3P-S5-TM/MAY/2009/5
www.AshleyEdison.com