Preview only show first 10 pages with watermark. For full document please download

Cvc-tm Series Three Phase 6kva ~ 1000kva

   EMBED


Share

Transcript

Ashley-Edison I Global Power Protection AC Constant Voltage Compensators / AC Automatic Booster Transformers CVC-TM SERIES THREE PHASE 6KVA ~ 1000KVA Installations with long cable runs have an inherent problem of developing high voltage drop across their cables. To overcome this, it is necessary to select and use larger sized electrical cables in order to reduce such voltage drop to an acceptable level. IEE Regulations stipulate that a volt drop should be no more than 4% which means that for a 3 phase 400V system, the drop across any length of cable shall not exceed 16 Volts. Therefore design engineers have to use larger cable size to cater for this drop. However, they also have to take the mains supply voltage fluctuations into consideration. Typically mains fluctuations is expected to be +/-6%. This means the engineer has to cater to wider voltage drop than necessary, leading to a larger size cable and this can be a very costly affair. Our Ashley-Edison’s Indoor Constant Voltage Compensators have been carefully designed with this application in mind. The New Parallel Redundant Voltage Regulation Control Module (VRCM) is incorporated on each phase of the Compensator. Should one Module fail or malfunction, the other parallel Module will operate automatically without causing interruption to the load and also without affecting capacity. The other phases not affected will still operate as normal. This will ensure that the voltage control is regulated continuously. This feature is especially useful for critical load application. Downtime is minimized. With the Compensator installed at the end of the cable line: • • • • This Voltage Drop problem will be resolved - voltage will be ‘compensated’ / boosted up to the required voltage. End voltage will be kept constant all the time, automatically, from no-load to full-load. Load change will not have any effect on this voltage - with the compensator installed, this voltage is kept constant continuously, automatically. Cable sizing is therefore reduced to a more affordable level. Cable installation is made more convenient due to smaller cable size. New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime. Utilizing Advanced Digital Controller HUGE SAVINGS with Ashley-Edison’s Constant Voltage Compensators Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost Models: High Voltage (H) Models 380/220V; 400/230V or 415/240V (Three Phase) Features: • • Low Voltage (L) Models 200/115V; 208/120V or 220/127V (Three Phase) • • • • CVC-TM/MAY/2009/5 Wide Range of Constant Voltage Compensator Three Phase Up to 1000KVA Input Voltage Range available from : (S1) 373V ~ 430V (S2) 352V ~ 430V (S3) 332V ~ 430V (S4) 311V ~ 430V (S5) 290V ~ 430V (To Specify) Output Voltage Regulation Output Voltage Accuracy ± 1%, High Efficiency Better than 98% Independent Phase Control Circuit Sensing on all Individual Three Phases Standard Protection Features Input circuit breaker Bypass control switch Over/low voltage protection Phase-failure protection Voltmeter / Selector switch ( Internal) • • • • Optional Accessories Output circuit breaker Ammeter / Selector switch Frequency meter Manual maintenance bypass switch Lightning arrester Compliance with International Standards BS EN50081-1;2/IEC 61000-4-3;4 BS EN5490/IEC 60529 CE Conformity EN55022,EN50082-2,ENV50140-1 Warranty 2 Years Applications • Communication Systems • • • • • • TV/Radio Broadcasting Stations Security Systems Communication Stations Lighting Systems Golf Course Lighting Systems Perimeter Lighting www.AshleyEdison.com CVC-H-S1-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage 373V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V Output Voltage Accuracy ± 1% Frequency 47 – 65 Hz Response Time <1.5ms Correction Time A 10% supply variation will be corrected to within 2.5% in 0.6 seconds Efficiency 98% Power Factor Any lagging to 0.95 leading Surge ratings 10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes Surge Suppression Protect loads against high-energy spikes and transient voltage. Total Harmonic Distortion <1% Independent Phase Control Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance Soft Switch-ON Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization Parallel Redundancy Module Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity Environment Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m Standard Features Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal) Construction Enclosures to IP20, BS EN5490 / IEC 60529 EMC Conformance BS EN50081-1;2 / IEC 61000-4-3;4 CE Conformity EN55022, EN50082-2,ENV50140-1 Optional Accessories Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime. Utilizing Advanced Digital Controller Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost Three Phase Model: CVC-H-3P-S1-TM Model: Dimensions (mm) WxHxD Weight (Kgs) 8.3 380 x 1240 x 780 190 Rating Amps Amps Amps KVA @ 380V @ 400V @ 415V CVC 6H-3P-S1-TM 6 9.1 8.7 CVC 10H-3P-S1-TM CVC 15H-3P-S1-TM 10 15.2 14.4. 13.9 380 x 1240 x 780 194 15 22.8 21.6 20.9 380 x 1240 x 780 197 CVC 20H-3P-S1-TM 20 30.4 28.9 27.8 380 x 1240 x 780 200 CVC 25H-3P-S1-TM 25 38 36.1 35 380 x 1240 x 780 200 CVC 30H-3P-S1-TM 30 46 43 42 380 x 1240 x 780 203 CVC 35H-3P-S1-TM 35 53 51 49 380 x 1240 x 780 200 CVC 40H-3P-S1-TM 40 61 58 56 380 x 1240 x 780 205 CVC 45H-3P-S1-TM 45 68 65 63 380 x 1240 x 780 209 CVC 50H-3P-S1-TM 50 76 72 70 380 x 1240 x 780 211 CVC 55H-3P-S1-TM 55 84 79 77 380 x 1240 x 780 213 CVC 60H-3P-S1-TM 60 91 87 83 380 x 1240 x 780 215 CVC 75H-3P-S1-TM 75 114 108 104 1000 x 1300 x 580 311 CVC 80H-3P-S1-TM 80 122 115 111 1000 x 1300 x 580 334 CVC 90H-3P-S1-TM 90 137 130 125 1000 x 1300 x 580 336 CVC 100H-3P-S1-TM 100 152 144 139 1000 x 1300 x 580 338 CVC 120H-3P-S1-TM 120 182 173 167 1000 x 1300 x 580 361 CVC 150H-3P-S1-TM 150 228 216 209 1280 x 1380 x 660 549 CVC 180H-3P-S1-TM 180 273 260 250 1280 x 1380 x 660 570 CVC 200H-3P-S1-TM 200 304 289 278 1280 x 1380 x 660 573 CVC 250H-3P-S1-TM 250 380 361 348 1280 x 1380 x 660 576 CVC 300H-3P-S1-TM 300 456 433 417 1280 x 1380 x 660 609 CVC 350H-3P-S1-TM 350 532 505 487 1280 x 1950 x 820 780 CVC 400H-3P-S1-TM 400 608 577 556 1280 x 1950 x 820 790 CVC450H-3P-S1-TM 450 684 649 626 1280 x 1950 x 820 970 CVC 500H-3P-S1-TM 500 760 722 695 1280 x 1950 x 820 980 Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice. CVC-3P-S1-TM/MAY/2009/5 www.AshleyEdison.com CVC-H-S2-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage 352V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V Soft Switch-ON Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization Parallel Redundancy Module Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity Environment Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m Standard Features Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal) Output Voltage Accuracy ± 1% Frequency 47 – 65 Hz Response Time <1.5ms Correction Time A 10% supply variation will be corrected to within 2.5% in 0.6 seconds Efficiency 98% Power Factor Any lagging to 0.95 leading Surge ratings 10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes Construction Enclosures to IP20, BS EN5490 / IEC 60529 EMC Conformance BS EN50081-1;2 / IEC 61000-4-3;4 Surge Suppression Protect loads against high-energy spikes and transient voltage. CE Conformity EN55022, EN50082-2,ENV50140-1 Total Harmonic Distortion <1% Optional Accessories Independent Phase Control Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime. Utilizing Advanced Digital Controller Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost Three Phase Model: CVC-H-3P-S2-TM Model: Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD Weight (Kgs) CVC 6H-3P-S2-TM 6 9.1 8.7 8.3 380 x 1240 x 780 190 CVC 10H-3P-S2-TM 10 15.2 14.4. 13.9 380 x 1240 x 780 194 CVC 15H-3P-S2-TM 15 22.8 21.6 20.9 380 x 1240 x 780 197 CVC 20H-3P-S2-TM 20 30.4 28.9 27.8 380 x 1240 x 780 200 CVC 25H-3P-S2-TM 25 38 36.1 35 380 x 1240 x 780 200 CVC 30H-3P-S2-TM 30 46 43 42 380 x 1240 x 780 203 CVC 35H-3P-S2-TM 35 53 51 49 380 x 1240 x 780 200 CVC 40H-3P-S2-TM 40 61 58 56 380 x 1240 x 780 205 CVC 45H-3P-S2-TM 45 68 65 63 380 x 1240 x 780 209 CVC 50H-3P-S2-TM 50 76 72 70 380 x 1240 x 780 211 CVC 55H-3P-S2-TM 55 84 79 77 380 x 1240 x 780 213 CVC 60H-3P-S2-TM 60 91 87 83 380 x 1240 x 780 215 CVC 75H-3P-S2-TM 75 114 108 104 1000 x 1300 x 580 311 CVC 80H-3P-S2-TM 80 122 115 111 1000 x 1300 x 580 334 CVC 90H-3P-S2-TM 90 137 130 125 1000 x 1300 x 580 336 CVC 100H-3P-S2-TM 100 152 144 139 1000 x 1300 x 580 338 CVC 120H-3P-S2-TM 120 182 173 167 1000 x 1300 x 580 361 CVC 150H-3P-S2-TM 150 228 216 209 1280 x 1380 x 660 549 CVC 180H-3P-S2-TM 180 273 260 250 1280 x 1380 x 660 570 CVC 200H-3P-S2-TM 200 304 289 278 1280 x 1950 x 820 706 CVC 250H-3P-S2-TM 250 380 361 348 1280 x 1950 x 820 766 CVC 300H-3P-S2-TM 300 456 433 417 1280 x 1950 x 820 946 CVC 350H-3P-S2-TM 350 532 505 487 1280 x 1950 x 820 1030 CVC 400H-3P-S2-TM 400 608 577 556 1280 x 1950 x 820 1041 CVC450H-3P-S2-TM 450 684 649 626 1280 x 1950 x 820 1210 CVC 500H-3P-S2-TM 500 760 722 695 1280 x 1950 x 820 1227 Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice. CVC-3P-S2-TM/MAY/2009/5 www.AshleyEdison.com CVC-H-S3-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage 332V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V Output Voltage Accuracy ± 1% Frequency 47 – 65 Hz Response Time <1.5ms Correction Time A 10% supply variation will be corrected to within 2.5% in 0.6 seconds Efficiency 98% Power Factor Any lagging to 0.95 leading Surge ratings 10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes Surge Suppression Protect loads against high-energy spikes and transient voltage. Total Harmonic Distortion <1% Independent Phase Control Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance Soft Switch-ON Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization Parallel Redundancy Module Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity Environment Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m Standard Features Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal) Construction Enclosures to IP20, BS EN5490 / IEC 60529 EMC Conformance BS EN50081-1;2 / IEC 61000-4-3;4 CE Conformity EN55022, EN50082-2,ENV50140-1 Optional Accessories Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime. Utilizing Advanced Digital Controller Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost Three Phase Model: CVC-H-3P-S3-TM Model: Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD Weight (Kgs) CVC 6H-3P-S3-TM 6 9.1 8.7 8.3 380 x 1240 x 780 198 CVC 10H-3P-S3-TM 10 15.2 14.4. 13.9 380 x 1240 x 780 200 CVC 15H-3P-S3-TM 15 22.8 21.6 20.9 380 x 1240 x 780 203 CVC 20H-3P-S3-TM 20 30.4 28.9 27.8 380 x 1240 x 780 206 CVC 25H-3P-S3-TM 25 38 36.1 35 380 x 1240 x 780 208 CVC 30H-3P-S3-TM 30 46 43 42 380 x 1240 x 780 209 CVC 35H-3P-S3-TM 35 53 51 49 380 x 1240 x 780 211 CVC 40H-3P-S3-TM 40 61 58 56 380 x 1240 x 780 213 CVC 45H-3P-S3-TM 45 68 65 63 380 x 1240 x 780 215 CVC 50H-3P-S3-TM 50 76 72 70 1000 x 1300 x 580 310 CVC 55H-3P-S3-TM 55 84 79 77 1000 x 1300 x 580 317 CVC 60H-3P-S3-TM 60 91 87 83 1000 x 1300 x 580 320 CVC 75H-3P-S3-TM 75 114 108 104 1000 x 1300 x 580 339 CVC 80H-3P-S3-TM 80 122 115 111 1000 x 1300 x 580 365 CVC 90H-3P-S3-TM 90 137 130 125 1000 x 1300 x 580 370 CVC 100H-3P-S3-TM 100 152 144 139 1000 x 1300 x 580 375 CVC 120H-3P-S3-TM 120 182 173 167 1280 x 1380 x 660 546 CVC 150H-3P-S3-TM 150 228 216 209 1280 x 1950 x 820 700 CVC 180H-3P-S3-TM 180 273 260 250 1280 x 1950 x 820 763 CVC 200H-3P-S3-TM 200 304 289 278 1280 x 1950 x 820 821 CVC 250H-3P-S3-TM 250 380 361 348 1280 x 1950 x 820 950 CVC 300H-3P-S3-TM 300 456 433 417 1280 x 1950 x 820 1152 CVC 350H-3P-S3-TM 350 532 505 487 1280 x 1950 x 820 1200 CVC 400H-3P-S3-TM 400 608 577 556 1280 x 1950 x 820 1217 CVC450H-3P-S3-TM 450 684 649 626 1280 x 1950 x 1200 1600 CVC 500H-3P-S3-TM 500 760 722 695 1280 x 1950 x 1200 1629 Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice. CVC-3P-S3-TM/MAY/2009/5 www.AshleyEdison.com CVC-H-S4-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage 311V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V Output Voltage Accuracy ± 1% Frequency 47 – 65 Hz Response Time <1.5ms Correction Time A 10% supply variation will be corrected to within 2.5% in 0.6 seconds Efficiency 98% Power Factor Any lagging to 0.95 leading Surge ratings 10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes Surge Suppression Protect loads against high-energy spikes and transient voltage. Total Harmonic Distortion <1% Independent Phase Control Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance Soft Switch-ON Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization Parallel Redundancy Module Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity Environment Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m Standard Features Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal) Construction Enclosures to IP20, BS EN5490 / IEC 60529 EMC Conformance BS EN50081-1;2 / IEC 61000-4-3;4 CE Conformity EN55022, EN50082-2,ENV50140-1 Optional Accessories Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime. Utilizing Advanced Digital Controller Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost Three Phase Model: CVC-H-3P-S4-TM Model: Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD Weight (Kgs) CVC 6H-3P-S4-TM 6 9.1 8.7 8.3 380 x 1240 x 780 200 CVC 10H-3P-S4-TM 10 15.2 14.4. 13.9 380 x 1240 x 780 203 CVC 15H-3P-S4-TM 15 22.8 21.6 20.9 380 x 1240 x 780 206 CVC 20H-3P-S4-TM 20 30.4 28.9 27.8 380 x 1240 x 780 209 CVC 25H-3P-S4-TM 25 38 36.1 35 380 x 1240 x 780 212 CVC 30H-3P-S4-TM 30 46 43 42 380 x 1240 x 780 215 CVC 35H-3P-S4-TM 35 53 51 49 1000 x 1300 x 580 310 CVC 40H-3P-S4-TM 40 61 58 56 1000 x 1300 x 580 315 CVC 45H-3P-S4-TM 45 68 65 63 1000 x 1300 x 580 320 CVC 50H-3P-S4-TM 50 76 72 70 1000 x 1300 x 580 332 CVC 55H-3P-S4-TM 55 84 79 77 1000 x 1300 x 580 337 CVC 60H-3P-S4-TM 60 91 87 83 1000 x 1300 x 580 342 CVC 75H-3P-S4-TM 75 114 108 104 1280 x 1380 x 660 542 CVC 80H-3P-S4-TM 80 122 115 111 1280 x 1950 x 820 679 CVC 90H-3P-S4-TM 90 137 130 125 1280 x 1950 x 820 689 CVC 100H-3P-S4-TM 100 152 144 139 1280 x 1950 x 820 699 CVC 120H-3P-S4-TM 120 182 173 167 1280 x 1950 x 820 752 CVC 150H-3P-S4-TM 150 228 216 209 1280 x 1950 x 820 841 CVC 180H-3P-S4-TM 180 273 260 250 1280 x 1950 x 820 985 CVC 200H-3P-S4-TM 200 304 289 278 1280 x 1950 x 820 1005 CVC 250H-3P-S4-TM 250 380 361 348 1280 x 1950 x 820 1179 CVC 300H-3P-S4-TM 300 456 433 417 1280 x 1950 x 820 1219 CVC 350H-3P-S4-TM 350 532 505 487 1280 x 1950 x 1200 1690 CVC 400H-3P-S4-TM 400 608 577 556 1280 x 1950 x 1200 1709 CVC450H-3P-S4-TM 450 684 649 626 1280 x 1950 x 1200 1750 CVC 500H-3P-S4-TM 500 760 722 695 1280 x 1950 x 1200 1770 Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice. CVC-3P-S4-TM/MAY/2009/5 www.AshleyEdison.com CVC-H-S5-TM Series Three Phase AC Constant Voltage Compensators Technical Specifications Input Voltage Range Output Voltage 290V ~ 430VAC, 3 Phase 4 Wire (3P+N) Presettable for any voltage between 380/220V; 400/230V or 415/240V Output Voltage Accuracy ± 1% Frequency 47 – 65 Hz Response Time <1.5ms Correction Time A 10% supply variation will be corrected to within 2.5% in 0.6 seconds Efficiency 98% Power Factor Any lagging to 0.95 leading Surge ratings 10 x max current rating for 2 seconds 3 x max current rating for 1 minutes 2 x max current rating for 5 minutes Surge Suppression Protect loads against high-energy spikes and transient voltage. Total Harmonic Distortion <1% Independent Phase Control Maintain each phase voltage stable irrespective of load unbalance, even up to 100% load unbalance Soft Switch-ON Ensure that the output voltage is at its minimum upon Switch-On before it commence full stabilization Parallel Redundancy Module Should one of these Control Units (VRCM) malfunction or fail, the Voltage Compensator will operate at 50% without affecting the compensator operation and without affecting capacity Environment Temperature range –15 to 45 °C. Derate by 2% for each additional °C Up to max 60 °C . Suitable for indoor tropical use 95% RH (non-condensing). Maximum altitude 1000m.Derate by 2.5% for each additional 500m Standard Features Input circuit breaker Over/Low voltage protection Phase failure protection Bypass control switch Voltmeter/selector switch (internal) Construction Enclosures to IP20, BS EN5490 / IEC 60529 EMC Conformance BS EN50081-1;2 / IEC 61000-4-3;4 CE Conformity EN55022, EN50082-2,ENV50140-1 Optional Accessories Output circuit breaker Ammeter/selector switch Frequency meter Lightning arrester Manual maintenance bypass switch Note: Optional accessories added may affect dimension, subject to confirmation. Note: 1) 208V 3Phase 3Wire or 4Wire options available on order 2) Special voltage configurations available on order 3) Higher KVA rating options available on order New, improved design enhances Compensator reliability with their proven, field-tested Parallel Redundant Voltage Regulation Control Module (VRCM) and serves as an added advantage of reducing inconvenient and expensive downtime. Utilizing Advanced Digital Controller Eliminate Voltage Drop in Long Cable Run and SAVE on Cable Cost Three Phase Model: CVC-H-3P-S5-TM Model: Rating Amps Dimensions (mm) Amps Amps KVA @ 380V @ 400V @ 415V WxHxD Weight (Kgs) CVC 6H-3P-S5-TM 6 9.1 8.7 8.3 380 x 1240 x 780 204 CVC 10H-3P-S5-TM 10 15.2 14.4. 13.9 380 x 1240 x 780 206 CVC 15H-3P-S5-TM 15 22.8 21.6 20.9 380 x 1240 x 780 209 CVC 20H-3P-S5-TM 20 30.4 28.9 27.8 380 x 1240 x 780 215 CVC 25H-3P-S5-TM 25 38 36.1 35 1000 x 1300 x 580 317 CVC 30H-3P-S5-TM 30 46 43 42 1000 x 1300 x 580 320 CVC 35H-3P-S5-TM 35 53 51 49 1000 x 1300 x 580 332 CVC 40H-3P-S5-TM 40 61 58 56 1000 x 1300 x 580 335 CVC 45H-3P-S5-TM 45 68 65 63 1000 x 1300 x 580 338 CVC 50H-3P-S5-TM 50 76 72 70 1280 x 1380 x 660 534 CVC 55H-3P-S5-TM 55 84 79 77 1280 x 1380 x 660 537 CVC 60H-3P-S5-TM 60 91 87 83 1280 x 1380 x 660 540 CVC 75H-3P-S5-TM 75 114 108 104 1280 x 1950 x 820 673 CVC 80H-3P-S5-TM 80 122 115 111 1280 x 1950 x 820 744 CVC 90H-3P-S5-TM 90 137 130 125 1280 x 1950 x 820 748 CVC 100H-3P-S5-TM 100 152 144 139 1280 x 1950 x 820 752 CVC 120H-3P-S5-TM 120 182 173 167 1280 x 1950 x 820 844 CVC 150H-3P-S5-TM 150 228 216 209 1280 x 1950 x 820 978 CVC 180H-3P-S5-TM 180 273 260 250 1280 x 1950 x 820 1134 CVC 200H-3P-S5-TM 200 304 289 278 1280 x 1950 x 820 1192 CVC 250H-3P-S5-TM 250 380 361 348 1280 x 1950 x 820 1320 CVC 300H-3P-S5-TM 300 456 433 417 1280 x 1950 x 1200 1600 CVC 350H-3P-S5-TM 350 532 505 487 1280 x 1950 x 1200 1800 CVC 400H-3P-S5-TM 400 608 577 556 1280 x 1950 x 1200 1820 CVC450H-3P-S5-TM 450 684 649 626 1280 x 1950 x 1200 2400 CVC 500H-3P-S5-TM 500 760 722 695 1280 x 1950 x 1200 2425 Copyright © 2009 Ashley-Edison reserve the right to change any or all of the specifications indicated or implied without prior notice. CVC-3P-S5-TM/MAY/2009/5 www.AshleyEdison.com