Preview only show first 10 pages with watermark. For full document please download

Cwdm-ge-xx-80x Applications Features Description Emc

   EMBED


Share

Transcript

CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant RoHS Pb Features Applications • CWDM 8 wavelengths Transmitter • Data Rate: 1.25Gbps, NRZ • Single +3.3V Power Supply • RoHS Compliant and Lead-free • AC/AC Differential Electrical Interface • Compliant with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP) • Compliant with SFF-8472 Digital Diagnostic Monitoring Interface ( optional ) • CWDM • Duplex LC Connector • Gigabit Ethernet Links • • Fibre Channel Links at 1.06 Gbps Compliance with specifications for IEEE-802.3z Gigabit Ethernet at 1.25 Gbps High Speed Backplane Interconnects • • Compliance with ANSI specifications for Fibre Channel applications at 1.06 Gbps • Switched Backbones • Eye Safety Designed to meet Laser Class 1 comply with EN60825-1 Description The CWDM-GE-xx-80x series from GEVISTA are the high performance and cost-effective modules for serial optical data communication applications specified for single mode of 1.25 Gb/s. It operates with +3.3V power supply. The module is intended for single mode fiber, operates at a nominal wavelength of CWDM and complies with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP). Each module is integrated digital diagnostics functions via an I2C serial interface ( optional ). The module is a duplex LC connector transceiver designed for use in Gigabit Ethernet applications and to provide IEEE-802.3z compliant link for 1.25Gb/s long reach applications. The characteristics are performed in accordance with ITU-T G.694.2 and G.695. EMC Most equipment utilizing high-speed transceivers will be required to meet the following requirements: 1) FCC in the United States 2) CENELEC EN55022 (CISPR 22) in Europe To assist the customer in managing the overall equipment EMC performance, the transceivers have been designed to satisfy FCC class B limits and provide good immunity to radio-frequency electromagnetic fields. Eye Safety The transceivers have been designed to meet Class 1 eye safety and comply with EN 60825-1. Page 1 of 6 CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant Product Information Model Number CWDM-GE-47-80 CWDM-GE-49-80 CWDM-GE-51-80 CWDM-GE-53-80 CWDM-GE-55-80 CWDM-GE-57-80 CWDM-GE-59-80 CWDM-GE-61-80 CWDM-GE-47-80D CWDM-GE-49-80D CWDM-GE-51-80D CWDM-GE-53-80D CWDM-GE-55-80D CWDM-GE-57-80D CWDM-GE-59-80D CWDM-GE-61-80D CWDM-GE-47-80T CWDM-GE-49-80T CWDM-GE-51-80T CWDM-GE-53-80T CWDM-GE-55-80T CWDM-GE-57-80T CWDM-GE-59-80T CWDM-GE-61-80T CWDM-GE-47-80DT CWDM-GE-49-80DT CWDM-GE-51-80DT CWDM-GE-53-80DT CWDM-GE-55-80DT CWDM-GE-57-80DT CWDM-GE-59-80DT CWDM-GE-61-80DT Wavelength Latch Color 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Operating Temperature. & Monitor Function Distance Output Power Sensitivity 0~70℃ 80 km 0 ~ +5 dBm ≦-24 dBm 0~70℃ with DDM 80 km 0 ~ +5 dBm ≦-24 dBm -40~85℃ 80 km 0 ~ +5 dBm ≦-24 dBm -40~85℃ with DDM 80 km 0 ~ +5 dBm ≦-24 dBm UNIT ℃ V V mA NOTE ABSOLUTE MAX RATINGS PARAMETER Storage Temperature Supply Voltage Data Input Voltage Supply Current SYMBOL TS VCC --IS MIN -40 0 0 SYMBOL VCC VID MIN. 3.1 300 MAX 85 6 Vcc 300 OPERATING CONDITIONS PARAMETER Supply Voltage Data Input Voltage Swing TYP. MAX. 3.5 1860 UNIT V mV NOTE Page 2 of 6 CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant ELECTRICAL CHARACTERISTICS PARAMETER Transmitter Transmitter Supply Current Tx_ Disable Input Voltage - Low Tx_ Disable Input Voltage - High Tx_ Fault Output Voltage - Low Tx_ Fault Output Voltage - High Receiver Receiver Supply Current Receiver Data Output Differential Voltage Rx_LOS Output Voltage - Low Rx_LOS Output Voltage - High MOD_DEF (1) , MOD_DEF (2) - Low MOD_DEF (1) , MOD_DEF (2) - High SYMBOL MIN MAX UNIT ICCT VIL VIH VOL VOH 0 2.0 0 2.0 200 0.8 Vcc 0.8 Vcc mA V V V V ICCR VOD VOL VOH VIL VIH 0.4 0 2.0 -0.6 Vcc × 0.7 100 1.3 0.8 Vcc Vcc × 0.3 Vcc + 0.5 mA V V V V V NOTE TRANSMITTER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Optical Output Power Extinction Ratio Center Wavelength Spectral Width (-20dB) Side Mode Suppression Ratio RIN Optical Rise time (20%-80% ) Optical Fall time (20%-80% ) Output Eye SYMBOL Po ER λc Δλ SMSR RIN tr tf MIN 0 9 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5 TYP. 1470 1490 1510 1530 1550 1570 1590 1610 MAX 5 1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5 1 30 -120 260 260 Compliant with IEEE802.3z/D5.0 UNIT dBm dB NOTE 1 nm nm dB dB/Hz ps ps 2 2 RECEIVER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Maximum Input Optical Power Minimum Input Optical Power Operating Wavelength Optical Return Loss Receiver Electrical 3dB Upper Cutoff Frequency LOS of Signal - Asserted LOS of Signal - Deasserted Loss of Signal -Hysterisis SYMBOL Pmax Pmin λ ORL --PA PD PD -PA MIN -3 1260 12 TYP. MAX -24 1620 1500 -35 -24 0.5 UNIT dBm dBm nm dB MHz dBm dBm dB NOTE 3 3 Page 3 of 6 CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant Notes: 1. Measured average power coupled into 9/125μm single mode fiber. 2. These are 20-80% values. 3. Measured with 27-1 PRBS at BER<10-12 TIMING CHARACTERISTICS PARAMETER TX_DISABLE Assert Time TX_DISABLE Negate Time Time to initialize, include reset of TX_FAULT TX_FAULT from fault to assertion TX_DISABLE time to start reset Receiver Loss of Signal Assert Time (off to on) Receiver Loss of Signal Assert Time (on to off) SYMBOL t_off t_on t_init t_fault t_reset tA,RX_LOS tD,RX_LOS BLOCK DIAGRAM OF TRANSCEIVER Electrical Sub-assem bly TD + LD D river TD - LD TX D isable TX Fault (0) (1) (2) M O D _DEF RD + Post-A m p RD - O ptical Sub-assem bly Duplex LC Receptacle PreAmp MIN TYP. UNIT μs ms ms μs μs μs μs 10 100 100 NOTE PIN OUT DIAGRAM OF TRANSCEIVER 20 VEET 1 VEET 19 TD- 2 Tx Fault 18 TD+ 3 Tx Disable 17 VEET 4 MOD-DEF2 16 VCCT 5 MOD-DEF1 15 VCCR 6 MOD-DEF0 14 VEER 7 Rate Select 13 RD+ 8 LOS 12 RD- 9 VEER 11 VEER 10 VEER Top of Board RX _LO S MAX 10 1 300 100 Buttom of Board (As Viewed through Top of Board PIN OUT TABLE Pin 1 Symbol VeeT Functional Description Transmitter Ground 2 TX Fault Transmitter Fault Indication 3 TX Disable Transmitter Disable – Module disables on high or open 4 MOD-DEF(2) Module Definition 2 – Two wire serial ID interface 5 MOD-DEF(1) Module Definition 1 – Two wire serial ID interface 6 MOD-DEF(0) Module Definition 0 – Grounded in module 7 Rate Select Not Connected 8 LOS Loss of Signal 9 VeeR Receiver Ground 10 VeeR Receiver Ground 11 VeeR Receiver Ground 12 RD- Inverse Received Data Out 13 RD+ Received Data Out 14 VeeR Receiver Ground Page 4 of 6 CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant 15 VccR Receiver Power 16 VccT Transmitter Power 17 VeeT Transmitter Ground 18 TD+ Transmitter Data In 19 TD- Inverse Transmitter Data In 20 VeeT Transmitter Ground Page 5 of 6 CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant RECOMMENDED CIRCUIT SCHEMATIC Vcc VEET VCCT RES Tx Fault RES Tx Disable 100 LD Driver TD+ Z o = 50 Ω TD- Z o = 50 Ω VCCT VCCR Pre Amp Post Amp L1 Vcc C2 L2 C3 C1 RD- Z o = 50 Ω RD+ Z o = 50 Ω System 100Ω Vcc RES RES RES EEPROM RES RX_LOS MOD-DEF(2) MOD-DEF(1) MOD-DEF(0) Note : 4.7 K Ω < RES < 10 K Ω L1, L 2 = 1μH C1 = 10μF C 2, C 3 = 0.1μF MECHANICAL DIMENSIONS Units in mm All dimensions are ±0.2mm unless otherwise specified. Claim: GEVISTA reserves the right to make changes in the specification described hereinafter without prior notice.125 Page 6 of 6