Transcript
CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant
RoHS Pb Features
Applications
•
CWDM 8 wavelengths Transmitter
•
Data Rate: 1.25Gbps, NRZ
•
Single +3.3V Power Supply
•
RoHS Compliant and Lead-free
•
AC/AC Differential Electrical Interface
•
Compliant with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP)
•
Compliant with SFF-8472 Digital Diagnostic Monitoring Interface ( optional )
•
CWDM
•
Duplex LC Connector
•
Gigabit Ethernet Links
•
•
Fibre Channel Links at 1.06 Gbps
Compliance with specifications for IEEE-802.3z Gigabit Ethernet at 1.25 Gbps
High Speed Backplane Interconnects
•
•
Compliance with ANSI specifications for Fibre Channel applications at 1.06 Gbps
•
Switched Backbones
•
Eye Safety Designed to meet Laser Class 1 comply with EN60825-1
Description The CWDM-GE-xx-80x series from GEVISTA are the high performance and cost-effective modules for serial optical data communication applications specified for single mode of 1.25 Gb/s. It operates with +3.3V power supply. The module is intended for single mode fiber, operates at a nominal wavelength of CWDM and complies with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP). Each module is integrated digital diagnostics functions via an I2C serial interface ( optional ). The module is a duplex LC connector transceiver designed for use in Gigabit Ethernet applications and to provide IEEE-802.3z compliant link for 1.25Gb/s long reach applications. The characteristics are performed in accordance with ITU-T G.694.2 and G.695.
EMC Most equipment utilizing high-speed transceivers will be required to meet the following requirements: 1) FCC in the United States 2) CENELEC EN55022 (CISPR 22) in Europe To assist the customer in managing the overall equipment EMC performance, the transceivers have been designed to satisfy FCC class B limits and provide good immunity to radio-frequency electromagnetic fields.
Eye Safety The transceivers have been designed to meet Class 1 eye safety and comply with EN 60825-1. Page 1 of 6
CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant
Product Information Model Number CWDM-GE-47-80 CWDM-GE-49-80 CWDM-GE-51-80 CWDM-GE-53-80 CWDM-GE-55-80 CWDM-GE-57-80 CWDM-GE-59-80 CWDM-GE-61-80 CWDM-GE-47-80D CWDM-GE-49-80D CWDM-GE-51-80D CWDM-GE-53-80D CWDM-GE-55-80D CWDM-GE-57-80D CWDM-GE-59-80D CWDM-GE-61-80D CWDM-GE-47-80T CWDM-GE-49-80T CWDM-GE-51-80T CWDM-GE-53-80T CWDM-GE-55-80T CWDM-GE-57-80T CWDM-GE-59-80T CWDM-GE-61-80T CWDM-GE-47-80DT CWDM-GE-49-80DT CWDM-GE-51-80DT CWDM-GE-53-80DT CWDM-GE-55-80DT CWDM-GE-57-80DT CWDM-GE-59-80DT CWDM-GE-61-80DT
Wavelength Latch Color 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm
Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown
Operating Temperature. & Monitor Function
Distance
Output Power
Sensitivity
0~70℃
80 km
0 ~ +5 dBm
≦-24 dBm
0~70℃ with DDM
80 km
0 ~ +5 dBm
≦-24 dBm
-40~85℃
80 km
0 ~ +5 dBm
≦-24 dBm
-40~85℃ with DDM
80 km
0 ~ +5 dBm
≦-24 dBm
UNIT ℃ V V mA
NOTE
ABSOLUTE MAX RATINGS PARAMETER Storage Temperature Supply Voltage Data Input Voltage Supply Current
SYMBOL TS VCC --IS
MIN -40 0 0
SYMBOL VCC VID
MIN. 3.1 300
MAX 85 6 Vcc 300
OPERATING CONDITIONS PARAMETER Supply Voltage Data Input Voltage Swing
TYP.
MAX. 3.5 1860
UNIT V mV
NOTE
Page 2 of 6
CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant
ELECTRICAL CHARACTERISTICS PARAMETER Transmitter Transmitter Supply Current Tx_ Disable Input Voltage - Low Tx_ Disable Input Voltage - High Tx_ Fault Output Voltage - Low Tx_ Fault Output Voltage - High Receiver Receiver Supply Current Receiver Data Output Differential Voltage
Rx_LOS Output Voltage - Low Rx_LOS Output Voltage - High MOD_DEF (1) , MOD_DEF (2) - Low MOD_DEF (1) , MOD_DEF (2) - High
SYMBOL
MIN
MAX
UNIT
ICCT VIL VIH VOL VOH
0 2.0 0 2.0
200 0.8 Vcc 0.8 Vcc
mA V V V V
ICCR VOD VOL VOH VIL VIH
0.4 0 2.0 -0.6 Vcc × 0.7
100 1.3 0.8 Vcc Vcc × 0.3 Vcc + 0.5
mA V V V V V
NOTE
TRANSMITTER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Optical Output Power Extinction Ratio
Center Wavelength
Spectral Width (-20dB) Side Mode Suppression Ratio RIN Optical Rise time (20%-80% ) Optical Fall time (20%-80% ) Output Eye
SYMBOL Po ER
λc
Δλ SMSR RIN tr tf
MIN 0 9 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5
TYP.
1470 1490 1510 1530 1550 1570 1590 1610
MAX 5 1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5 1
30 -120 260 260 Compliant with IEEE802.3z/D5.0
UNIT dBm dB
NOTE 1
nm
nm dB dB/Hz ps ps
2 2
RECEIVER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Maximum Input Optical Power Minimum Input Optical Power Operating Wavelength Optical Return Loss Receiver Electrical 3dB Upper Cutoff Frequency
LOS of Signal - Asserted LOS of Signal - Deasserted Loss of Signal -Hysterisis
SYMBOL Pmax Pmin λ ORL --PA PD PD -PA
MIN -3 1260 12
TYP.
MAX -24 1620 1500
-35 -24 0.5
UNIT dBm dBm nm dB MHz dBm dBm dB
NOTE 3 3
Page 3 of 6
CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant Notes: 1. Measured average power coupled into 9/125μm single mode fiber. 2. These are 20-80% values. 3. Measured with 27-1 PRBS at BER<10-12
TIMING CHARACTERISTICS PARAMETER TX_DISABLE Assert Time TX_DISABLE Negate Time Time to initialize, include reset of TX_FAULT TX_FAULT from fault to assertion TX_DISABLE time to start reset Receiver Loss of Signal Assert Time (off to on) Receiver Loss of Signal Assert Time (on to off)
SYMBOL t_off t_on t_init t_fault t_reset tA,RX_LOS tD,RX_LOS
BLOCK DIAGRAM OF TRANSCEIVER Electrical Sub-assem bly TD +
LD D river
TD -
LD
TX D isable TX Fault (0) (1) (2)
M O D _DEF
RD +
Post-A m p
RD -
O ptical Sub-assem bly
Duplex LC Receptacle
PreAmp
MIN
TYP.
UNIT μs ms ms μs μs μs μs
10 100 100
NOTE
PIN OUT DIAGRAM OF TRANSCEIVER 20
VEET
1
VEET
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
VEET
4
MOD-DEF2
16
VCCT
5
MOD-DEF1
15
VCCR
6
MOD-DEF0
14
VEER
7
Rate Select
13
RD+
8
LOS
12
RD-
9
VEER
11
VEER
10
VEER
Top of Board
RX _LO S
MAX 10 1 300 100
Buttom of Board (As Viewed through Top of Board
PIN OUT TABLE Pin 1
Symbol VeeT
Functional Description Transmitter Ground
2
TX Fault
Transmitter Fault Indication
3
TX Disable
Transmitter Disable – Module disables on high or open
4
MOD-DEF(2)
Module Definition 2 – Two wire serial ID interface
5
MOD-DEF(1)
Module Definition 1 – Two wire serial ID interface
6
MOD-DEF(0)
Module Definition 0 – Grounded in module
7
Rate Select
Not Connected
8
LOS
Loss of Signal
9
VeeR
Receiver Ground
10
VeeR
Receiver Ground
11
VeeR
Receiver Ground
12
RD-
Inverse Received Data Out
13
RD+
Received Data Out
14
VeeR
Receiver Ground
Page 4 of 6
CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant 15
VccR
Receiver Power
16
VccT
Transmitter Power
17
VeeT
Transmitter Ground
18
TD+
Transmitter Data In
19
TD-
Inverse Transmitter Data In
20
VeeT
Transmitter Ground
Page 5 of 6
CWDM-GE-xx-80x 1.25 Gigabit Ethernet-Single mode Transceiver CWDM SFP, Duplex LC Connector, 1470nm~1610nm DFB DDM Power Budget 24dB, 80km for Single Mode Fiber, RoHS Compliant
RECOMMENDED CIRCUIT SCHEMATIC Vcc VEET
VCCT
RES
Tx Fault RES
Tx Disable
100
LD Driver
TD+
Z o = 50 Ω
TD-
Z o = 50 Ω
VCCT VCCR
Pre Amp
Post Amp
L1
Vcc
C2 L2 C3
C1
RD-
Z o = 50 Ω
RD+
Z o = 50 Ω
System 100Ω
Vcc RES
RES
RES
EEPROM
RES
RX_LOS MOD-DEF(2) MOD-DEF(1) MOD-DEF(0)
Note : 4.7 K Ω < RES < 10 K Ω L1, L 2 = 1μH C1 = 10μF C 2, C 3 = 0.1μF
MECHANICAL DIMENSIONS Units in mm
All dimensions are ±0.2mm unless otherwise specified.
Claim: GEVISTA reserves the right to make changes in the specification described hereinafter without prior notice.125
Page 6 of 6