Preview only show first 10 pages with watermark. For full document please download

Cx Series

   EMBED


Share

Transcript

CX Series • SIP SSR • Ratings of 5A @ 660 VAC • SCR output for heavy industrial loads • AC or DC control • Zero-crossing (resistive loads) or random-fire (inductive loads) output • CE Compliant to EN60950-1 PRODUCT SELECTION Control Voltage 3-15 VDC 4-15 VDC 15-32 VDC 18-36 VAC 90-140 VAC 5A 5A 5A CX380D5 CXE380D5 CX480D5 CXE480D5 CX240D5 CXE240D5 CXE240A5 CX240A5 AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) Maximum Load Current [Arms] Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum I²t for fusing (8.3 msec) [A² sec] Minimum Power Factor (with Maximum Load) HP rating UL 508/IEC60947[HP/KW]: 240VAC HP rating UL 508/IEC60947[HP/KW]: 380VAC HP rating UL 508/IEC60947[HP/KW]: 480VAC CX240x5 CX380x5 CX480x5 12-280 600 0.1 500 5 0.06 250 1.4 260 0.5 0.25/0.18 NA NA 48-530 1200 0.1 500 5 0.06 250 1.4 260 0.5 0.25/0.18 0.33/0.25 NA 48-660 1200 0.1 500 5 0.06 250 1.4 260 0.5 0.25/0.18 0.33/0.25 0.5/0.37 INPUT SPECIFICATIONS (1) Description CX240Dx Nominal Voltage Control Voltage Range Minimum Turn-On Voltage Drop Out Voltage Typical Input Current Nominal Input Impedance Maximum Turn-On Time [msec] (3) Maximum Turn-Off Time [msec] 5 VDC 3-15 VDC 3.0 VDC 1.0 VDC 15 mAdc 300 Ohm 1/2 Cycle 1/2 Cycle CX380/480Dx 5 VDC 4-15 VDC 4.0 VDC 1.0 VDC 15 mAdc 240 Ohm 1/2 Cycle 1/2 Cycle CXExxxDx 24 VDC 15-32 VDC 15.0 VDC 1.0 VDC 15 mAdc 1500 Ohm 1/2 Cycle 1/2 Cycle CX240A5 120 VAC 90-140 VAC 90.0 Vrms 10.0 Vrms 10 mArms 14.1K Ohm 10 40 GENERAL SPECIFICATIONS Description Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 3) Turn-On time for random turn-on versions is 0.1 msec (DC Control Models). WIRING DIAGRAM Parameters 4000 Vrms 10 9 Ohm 10 pF -30 to 80 °C -30 to 125 °C 0.4 oz. (11g) Therminally Conductive Epoxy CXE240A5 24 VAC 18-36 VAC 18.0 Vrms 2.0 Vrms 10 mArms 2.1K Ohm 10 40 MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 CE EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: E116949 LR81689 70938 (240 V, 380V, DC Control Only) Rev. 110512 ANNEX - ENVIROMENTAL INFORMATION Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crydom: CX240A5R CX480D5 CXE240A5 CXE240D5 CXE240A5R CXE380D5 CX240D5 CX240D5R CXE480D5 CX380D5 CX380D5R CX480D5R CXE380D5R CXE480D5R CX240A5 CXE240D5R