Transcript
CPSWW.COM
UPS SYSTEMS PORTFOLIO
UC0014EU-00
The CyberPower Story
Our Core Values
Founded in 1997, CyberPower has followed a path to success through engineering excellence and quality standards in power protection and computer accessories. At our advanced technology manufacturing facilities, we build a comprehensive line of power protection products, including Uninterruptible Power Supplies (UPS), Power Distribution Units (PDUs), Power Inverters, Surge Protectors, Mobile Chargers, power management software, and computer peripheral accessories. With a global presence we provide award-winning products that offer reliable power protection and a sense of security.
In-house Laboratory for Certified Testing
CyberPower continuously invests in its in-house laboratory and testing capabilities to deliver the highest standard of product verification and testing. Through our certified capabilities we are able to perform safety tests in-house, offer certificates of EMI, Energy Star and related pre-testing. Audited by 3rd party certificate labs including UL, TUV, SGS, Intertek and CSA, this facility ensures a timely development process as well as compliance with worldwide legal standards.
No matter whether you are an IT professional working in a corporate data centre, an owner of a small-tomedium business, or a consumer using electronic devices at home, CyberPower has a wide range of power solutions to safeguard your critical equipment and valued data.
Comprehensive Power Solutions
As a professional power solution provider, CyberPower designs and manufactures a comprehensive range of innovative power products, including Mobile Inverters, Surge Protectors, PDU & Power Management, Mobile Chargers and PV Inverters. Our exceptional R&D capabilities enable us to produce a full range of power products, all highly engineered, resulting in top quality UPS solutions.
Global Distributions CyberPower products are available through authorised distributors and sold by valuedadded resellers, system integrators, wellknown e-tailers and selected retail channels worldwide. We have a global presence via offices and distribution centers located in Americas (Canada, Mexico and the United States), Europe (France, German, Russia and the Netherlands), Asia (Japan, Taiwan, China, Thailand, Philippines, Indonesia, Myanmar, etc.), Oceania(Australia, New Zealand and Fiji), and Africa (Algeria, Cameroun, Chad and Republic Democratic of Congo) and beyond.
USA Office Minneapolis, USA
German Office München, Germany
Mexico Office Mexico City
In response to the growing demand for Green IT products, CyberPower has developed patented GreenPower UPSTM Energy-Saving Technology to improve UPS operating efficiency and greatly reduce energy consumptions. As a result, our customers can enjoy significant energy cost savings over conventional UPS systems.
Japan Office Tokyo, Japan
France Office Cloyes, France India Office Mumbai / Bengaluri / Kolkata / New Delhi, India 4 Manufacturing Factories Shenzhen / Hunan, China China Office Shenzhen, China
The markets and worlds in which we live are changing in the blink of an eye, reacting rapidly to these changes has become a top priority for businesses today. Thanks to our efficient supply chain management strategy and systematic integration capability, we are able to meet this requirement for fast response to demanding markets.
GreenPower UPSTM Technology
Russia Office Moscow, Russia
The Netherlands Office Eindhoven, the Netherlands
Fast Response Ability
Taipei Office & R&D Center Taipei, Taiwan
Our Green Fact Power Consumption: GreenPower UPS™ Technology vs. Other UPS Brands
Power Consumption
Reduce Energy Cost Using Energy-saving Technology
60
Test 1 Unit Off No AC Load No DC Load
50
The GreenPower UPS™ Technology features multiple advanced energy-saving designs that improve operating efficiency and eliminate waste energy consumptions. Featuring
Test 2 Unit On (AVR Off) No AC Load No DC Load
40
advanced high-frequency design and patented bypass circuit design, users can enjoy significant energy savings with the adoption of GreenPower UPS™
30
Technology.
Test 3 Unit On (AVR Off) Full AC Load No DC Load (Battery Full Charged)
20 10
*Test result may vary in different test environments.
0
Smart App Professional Rackmount Series
Power Efficiency
Other UPS Brand 1
Other UPS Brand 2
Our product can outperform other brands under any conditions
100% 90% 80%
Under 25% load: 9% higher than other brands
70%
Under 50% load: 7% higher than other brands
Under 100% load: 3.6% higher than other brands
Double Conversion On-Line UPS
• High Frequency Inverter: Increased conversion efficiency and reduced energy loss when the inverter is converting DC to AC power during Battery Mode.
Heat
Energy Loss
Heat
Energy Loss
Continuous Devotions to Green Management Power Flow
Charge
bAT.
Outgoing AC Power
Incoming AC Power
Heat
Energy Loss
GreenPower UPS™ Technology increases the efficiency of your UPS by saving energy during normal utility power operation. Energy & Heat Losts
The commitment to innovation, excellence, and efficiency extends throughout our company, CyberPower has adopted Green practices and certifications throughout the business, including: Membership in the Climate Savers Computing Initiative, the adoption of Restriction on Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment (WEEE) protocol, certification in ISO 14001 Environmental Management Systems and IECQ QC 080000 HSPM Hazardous Substance Process Management Standards, qualifications of ENERGY STAR®, patented energy-saving GreenPower UPS™ Technology, and other ongoing “Greening” of all packaging practices and materials to ensure the maximum consideration for the environment.
CyberPower GreenPower UPSTM
ISO14001
Outgoing AC Power noise Filter
Charge
bAT.
IECQ QC080000
Load
95%
100%
90%
84%
82%
74%
69%
67%
64%
59%
56%
48%
46%
40%
35%
33%
30%
27%
24%
23%
22%
*Comparison between CyberPower Smart App Professional Rackmount Series and other UPS brands.
Line Interactive UPS
noise Filter
Incoming AC Power
18%
1. UPSs working in in-line mode with resistive load. 2. Batteries are fully charged.
bAT.
No
Bypass Circuit Design While conventional UPS systems pass power through a transformer to provide normal output voltage to protect devices, the patented GreenPower UPS™ circuitry bypasses the transformer during normal utility power operation, which significantly increases the power efficiency of the UPS. As utility power is normal in over 88% of the time, GreenPower UPS™ Technology operates primarily in its cost-reducing bypass mode, thus lowering energy costs by up to 75% compared to conventional UPS models.
Power Conversion
16%
Unstable utility supply
Power Conversion
12%
Suiting Stable Utility supply
noise Filter
8%
Operating environment
0% Charge
11%
Varies depending on model
10%
7%
No
Energy saving
Brand A-UPS1500 Brand B-UPS1500
6%
AVR
Physical Efficiency Stability
CyberPower-PR1500ELCDRT2U
20%
5%
Conventional UPS Larger in size / Heavier Less efficiency Better stability
30%
3%
High Frequency UPS Smaller in size / Lighter Better efficiency Advanced circuit design for good stability Yes, less energy loss during charging and/ or conversion
40%
2%
• High Efficiency Charger: Increased charging efficiency and reduced energy loss during the battery charging process in AC Mode.
50%
1%
High-Frequency Design The high-frequency design includes a compact energy-efficient inverter and charger with the following features:
Traditional online double-conversion and line-interactive UPS designs can have efficiencies as low as 85% under full load. The energy lost by these UPS designs during normal utility power operation is significant.
0%
The GreenPower UPS™ Design
Efficiency
60%
Choosing the Right UPS for Your Equipment An uninterruptible Power Supply (UPS) provides battery backup power and extra runtime to connected devices when the input power source, usually utility power, fails or drops to an unexpected voltage level. For small UPS systems, the on-battery runtime is relatively short, usually just a few minutes, yet sufficient for operators to save files and power down computers in an orderly manner. For large UPS systems, most industry-level UPSs accept optional external battery packs for additional runtime, often up to several hours.
At CyberPower, we offer users, from Home Office to IT Professionals, a wide selection of UPS solutions. All designed to protect sensitive equipment and valued data from harm caused by power problems. To better assist you in choosing the right power solution for your equipment, typology and output wave form requirement, we have produced this summary to help you understand the different options:
Topologies Essential Protection ▬ Offline/Standby
The Standby UPS, also known as Offline UPS to be distinguished from Online UPS, is the simplest and least expensive UPS type. Primary power source is utility power and battery is the second. Normally, the battery remains charged by utility power and the inverter only starts when AC power fails, hence being known as “Standby”.
Seamless Connection & Ultimate Protection ▬ Online (Double Conversion Topology)
In the Online (Double Conversion) UPS, failure of input AC will not cause the activation of the transfer switch, as the primary power source is NOT the utility power, but the backup source instead. During normal operation, the UPS is running off the battery and using its inverter for loads while the battery charger is running from line power, hence the name of Online (Double Conversion) UPS. In the event of power failure, only the battery charger would fail and the inverter will keep providing loads as normal from the battery. As no transfer time is needed when the power goes out, equipment powered by an Online UPS can remain operating without interruption, so that makes it perfect for valued devices that have zero tolerance of power outages! Also, with the equipment running off the battery most of the time, any noisy power or unpleasant surprises from the wall socket can be isolated from the output loads and affect only the battery charger. Therefore, the Online UPS can ensure continuous, consistent and clean pure sine wave power to mission-critical equipment, regardless of the incoming power.
Features
Below is a list of innovative features that can be found on CyberPower UPS products. Some features may only be available on selected products. For detailed features and specifications of each UPS model, please refer to our website at www.cpsww.com. • Automatic Voltage Regulation (AVR) • Critical Load Outlets • Emergency Power Off Port (EPO) • GreenPower UPS™ Technology • Multifunction LCD Display Panel
• Convertible Rack/Tower Configuration • Data and Phone Line Protection • Extended Runtime • Hot-Swappable, Front-Load Batteries • PowerPanel® Management Software
Applications
The common applications of UPS systems are:
PCs / WORKSTATIONS Monitors, PCs or external peripherals
AUDIO / VIDEO SYSTEMS Stereos, TV, DVD players, Games consoles
NETWORK DEVICES Hubs, routers, switches, and Wireless AP
OFFICE DEVICES Fax machines, scanners, and projectors
EMERGENCY SYSTEMS Emergency lightings, alarm systems, safety systems
DATA STORAGE ARRAYS RAID systems and tape drivers
TELECOM DEVICES Home systems, monitoring systems and POS
DVRs / SURVEILLANCE SYSTEMS Safety and surveillance systems
SERVERS Firewalls, data centers or server rooms
INDUSTRIAL EQUIPMENT Central control systems, factories
BYPASS IN
AC/DC PFC SWITCH
BATTERY CHARGER
AC
OUT
AC DC
DC
AC
AC INVERTER
DC DC
INVERTER
DC
BUS
BATTERY CHARGER
AC DC
IN
DC/DC
SWITCH
OUT
DC CONVERTER
BATTERY
BATTERY
Professional & Advanced Protection ▬ Line-Interactive
The Line-Interactive UPS is the most common design used for SMEs, Corporate Servers and Industrial Equipment. In this design, the AC power is still the primary power source while the battery power is secondary. However, the biggest difference from Standby UPS is that the inverter/converter unit stays permanently connected to the output for powering equipment compared. When the power fails, this design demonstrates a faster response time compared to Standby UPS, while providing additional filtering of switching transients and spikes. Automatic Voltage Regulation is another important feature that comes with most Line-Interactive UPS as it regulates high and low voltages and bring the power to a consistent nominal level. This allows the UPS to maintain safe power levels without resorting to to battery power, which significantly reduces the premature battery failure caused by frequent battery usage. It also reduces the chances of data loss, memory freezes, and system crashes. IN
Output Waveform Simulated/Stepped Sine Wave The Simulated Sine Wave can be seen as a satisfactory compromise between cost and power quality. While not as pure sine wave AC power, this wave form is acceptable for most consumer electronics products. Simulated Sine Wave system produces decent battery power at a reasonable cost, hence making it widely adopted in entry- to midlevel UPS products.
AVR SWITCH
BATTERY CHARGER
AC
AC DC
DC INVERTER
BATTERY
OUT
Pure Sine Wave As the highest level of line clarity, Pure Sine Wave is the most ideal waveform for mission-critical equipment. While Simulated Sine Wave output produces a sine wave that is “stepped” or modified, Pure Sine Wave output produces a true sine wave that is similar to normal AC wall power that ensures continuous optimal operation. UPSs with Pure Sine Wave are designed for electronics utlising Active PFC power supplies or other devices that require pure sine wave .
The Second-to-None in UPS Technology
PowerPanel® Management Software PowerPanel® Management Software is an integral component of battery backup and data protection solutions, packaged with most CyberPower UPS products. The intuitive dashboard interface is extremely easy to navigate for first-time users and powerful enough for administrators and system integrators. In the event of power loss, PowerPanel automatically saves files and safely shuts down the computer in an orderly manner.
PowerPanel® for mac & Mac energy saver
®
PowerPanel Personal edition
PowerPanel® for Mac is now available to provide Mac users with statistics and status information of connected CyberPower UPS via USB connection. During a power event, users can safely shut down their Mac via either the PowerPanel software or Mac Energy Saver. PowerPanel for Mac is compatible with Mac OS X 10.4.1+. * For more information, please visit www.CPSww.com under “Software”.
PowerPanel® Personal edition PowerPanel® Personal Edition is designed for small office use and features a heads-up graphical interface. The friendly dashboard-style interfaces of PowerPanel® Personal Edition software make it easy to control and monitor the UPS system with a USB or serial port. In the event of power loss, the software automatically saves files, shuts down computer, and enters OS hibernation in a safe, intelligent and orderly manner. It combines graphical and statistical data in a compact, easy-to-install package is fully compatible with Mac, Linux, Windows 8, 7, Vista, XP, Window Server 2012, 2008 and 2003. Software Features • User-friendly Dashboard Interface • Load/Current Draw and Runtime Status • System Tray Notifications • Automatic File-saving, Equipment Shutdown, and OS Hibernation • Scheduled-shutdown and Restart
PowerPanel® for mac & Mac energy saver POWERPANEL® for LINUX PowerPanel® for Linux allows control and monitoring of UPS attached to a Linux based computer to manage the protection of computer systems, components, peripherals, as well as the data. In the event of power loss, PowerPanel will safely shut down computers in a safe and orderly manner.
POWERPANEL® for LINUX
PRODUCT INDEX
Home & Home Office
BRICS LCD SERIES
● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● USB Connectivity Port ● User-Replaceable Batteries ● Horizontal/Wall-Mounted Use ● Cable Collector Included ● External Battery Charger* ● USB Charging Port* ● PowerPanel® Personal Edition Software
● GreenPower UPS™ Technology ● EMI, RFI, Surge and Lightning Spike Protection ● Auto-Restart / Auto-Charge ● USB Connectivity Port ● User-Replaceable Batteries ● Horizontal / Wall-Mounted Use ● Cable Collector Included ● PowerPanel® Personal Edition Software
14
15
P.
EX SERIES ● GreenPower UPSTM Technology ● EMI, RFI, Surge and Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LED Status Indicator ● USB Connectivity Port ● Easy Battery Replacement ● PowerPanel® Personal Edition Software
HOME THEATER SYSTEM VALUE SERIES
18
VALUE SOHO SERIES ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● USB & Serial Connectivity Ports ● User-Replaceable Batteries ● PowerPanel® Personal Edition Software
13
SMALL OFFICE
P.
DX / DL SERIES
● GreenPower UPS™ Technology ● EMI, RFI, Surge and Lightning Spike Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor* ● USB Connectivity Port ● PowerPanel® Personal Edition Software
17
P.
● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LED Status Indicators* ● LCD Status Monitor* ● USB & Serial Connectivity Ports ● PowerPanel® Personal Edition Software
P.
16
P.
BS SERIES P.
PRODUCT INDEX
Backup UPS Systems The Backup UPS Systems offers home and small office users peaceof-mind of surge protection and battery backup for protection against brownouts, AC power sags and total power outages.
MEDIUM BUSINESS
19
P.
20
P.
PFC SINEWAVE SERIES ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● User-friendly Control Switch USB Charging Ports* ● User-Replaceable Batteries ● PowerPanel® Personal Edition Software
INTELLIGENT LCD SERIES ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● USB Connectivity Port ● User-Replaceable Batteries ● PowerPanel® Personal Edition Software
*= Select Models
FEATURE INDEX
FEATURE INDEX Cable Collector A well-suited solution to better assist in maintaining a neat and tidy work space. It simplifies the cable arrangement therefore increases the structural reliability for the total set of distribution cables.
RJ11/RJ45 PROTECTION
CABLE COLLECTOR
RJ11/RJ45 Protection
AUTOMATIC VOLTAGE REGULATION (AVR)
The RJ11/RJ45 port is designed to protect data lines and communication equipment from AC transients caused by surge, electrostatic discharge and other power abnormalities.
AVR INCONSISTENT UTILITY POWER
CONSISTENT SAFE POWER
Automatic Voltage Regulation (AVR)
Convenient Mounting A space-wise design that allows multiple mounting options including horizontal, cabinet and wall-mounted orientation to make the most of your workspace.
MULTIFUNCTION LCD READOUT
CONVENIENT MOUNTING
Detailed display.
Clear and consistent LCD readout of power/battery status including load, runtime, power, AVR and other information at a single push-of-abutton. Also, advanced settings can be configured to the potential power problems in advance.
Multifunction LCD Readout Compact display.
Comparison Table Model DX/DL Series EX Series BS Series BRICs LCD Series Value Series Value SOHO Series Intelligent LCD Series PFC Sinewave Series *= Select Models
Form Factor Tower Tower Brick Brick Tower Tower Tower Tower
Waveform ** ** ** ** ** ** ** Pure Sine Wave
** =Featured with Simulated Sine Wave
LCD * v * v v v
COMPARISON TABLE AVR v v v v v
VA 450-850 650-850 450-850 650-1000 600-2200 600-2200 1050-1500 900-1500
Watt 270-490 360-490 270-490 390-600 360-1320 360-1320 630-900 540-900
Outlets 3 3 6 6 3/6 2/4 6 6
RJ11/45 v v v v v v
USB v v v v v v v v
Software v v v v v v v v
Designed for Home / SOHO Home / SOHO Home / SOHO Home / SOHO Home / SOHO / SMEs* Home / SOHO / SMEs* Home / SOHO / SMEs Home / SOHO / SMEs
Clear and consistent LCD readout of power/battery status including load, runtime, power and other information at a single push-of-a-button. Also, advanced settings can be configured to the potential power problems in advance.
LCD DISPLAY INFORMATION TABLE
Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level for the connected equipment. AVR regulates high and low voltages and brings the power to a nominal 220/240 volts. This allows the UPS to maintain safe power levels without resorting to battery power, which significantly increases battery life and eliminates AC-DC power transfer when minor power fluctuations occur. It also reduces the chances of data loss, memory freezes and system crashes.
LCD Display Information Table Load/Current Level AVR in Use* Overload Silent Mode Battery Pack Numbers* Temperature (F and C)*
Runtime Battery in Use Battery Level Battery Shutdown Voltage Static Frequency Tolerance
Output Frequency* Input Voltage Output Voltage Normal Operation Slew Rate * = Select Models
13 DX / DL SERIES
EX SERIES
14
RJ11/RJ45 Data Line Protection
The RJ11/RJ45 Data Line Protection serves to protect phone, data lines and communication equipment against AC transients caused by surge, electrostatic discharge and other power abnormalities.
Designed for home and office users, the DX/DL Series UPS provides the most cost-effective battery backup for PCs and SOHO networks. With EMI/RFI filters eliminating line noise or disturbances, it can supply reliable backup during power interruptions, brownouts and blackouts. The DL Series also features a multifunction LCD readout for immediate access to precise information about critical power/battery condition. With its cutting-edge compact design, it can make the most of your workspace.
Featuring a surge protected RJ11/RJ45 port, the EX Series UPS is ideal for home entertainment systems and SOHO networks, offering full protection against surge/spikes and power abnormalities. With EMI/RFI filters eliminating line noise or disturbances, it can supply reliable backup during power interruptions, brownouts and blackouts. Its Space-wise tower design means it can be placed horizontally or vertically to make the most your workspace!
1. Power On/Off Switch 2. LED Status Indicator 3. Battery Capacity Indicator 4. LCD Display 5. LCD Function Select Switch* 6. AC Outlets* 7. Communication Port to PC (USB) 8. Circuit Breaker Protection
3 4
2 1
1
5
2
7
3
6 1. Power On/Off Switch 2. AC Outlets* 3. Communication Protection Ports RJ11/RJ45
UK socket*
FR socket*
5 8
UK socket*
FR socket*
*= Other socket types available upon request
4
4. Communication Port to PC (USB) 5. Circuit Breaker Protection
AS socket*
*= Other socket types available upon request AS socket*
Technical Specifications Model Name
EX650E
EX850E
General
Technical Specifications Model Name
DX450E
DX650E
DX850E
DL450ELCD
DL650ELCD
DL850ELCD
General
UPS Topology
Standby
Energy Saving
Yes
Input Voltage
UPS Topology
Standby
Energy Saving
Yes
192Vac - 263Vac
Input Frequency Range
Input
50/60Hz ± 3Hz (Auto-sensing)
Rated Input Current
Voltage
230Vac
Input Voltage Range
5A
Plug Type
Schuko or UK or NEMA
VA
650
850
Watts
360
490
On Battery Waveform
Output
230Vac ± 10% 50/60Hz ± 1%
450
650
850
450
650
850
On Battery Frequency
Watts
270
360
490
270
360
490
Outlets - Total
Simulated Sine Wave 230Vac ± 7%
Outlets - Battery & Surge Protected
On Battery Frequency
50/60Hz ± 1%
Transfer Time
3
Outlet Type
3
Outlet Type
On Battery Voltage Outlets - Total
Simulated Sine Wave
On Battery Voltage
VA On Battery Waveform
Schuko or UK
Output
50/60Hz ± 3Hz (Auto-sensing)
Rated Input Current
10A
Plug Type
192Vac - 263Vac
Input Frequency Range
Schuko or FR or UK (UK x 2 + IEC x 1) 2 4ms
Battery
Schuko or FR or UK (UK x 2 + IEC x 1) or AS
Runtime at Half Load (min)
6
3
Runtime at Full Load (min)
1
Outlets - Battery & Surge Protected Transfer Time
4ms
7 2
Battery Type
Battery
Sealed Lead Acid
Battery Quantity
Runtime at Half Load (min)
6
6
7
Runtime at Full Load (min)
2
1
2
Battery Type
6
6
7
User Replaceable
2
1
2
Typical Recharge Time
Sealed Lead Acid
Battery Quantity
Replacement Battery Pack
1
Typical Recharge Time
1 Yes 8 Hours RBP0080
RBP0081
Replacement Battery Pack Quantity
8 Hours
1
Surge Protection & Filtering
Surge Protection & Filtering
Surge Suppression
Surge Suppression
405 Joules
1215 Joules
Phone / Network Protection RJ11/RJ45
Management & Communications
1-In, 1-Out (Combo)
Management & Communications
HID Compliant USB Port
Yes
LED Indicators
HID Compliant USB Port
Using AC, Using Battery, Fault, Battery Capacity
Audible Alarms
On Battery, Low Battery, Overload,Fault PowerPanel® Personal Edition
Software
Yes
LED Indicators
Power On, Wiring Fault
Audible Alarms
On Battery, Low Battery, Overload PowerPanel® Personal Edition
Software
Physical
Physical
Form Factor
Tower
Form Factor
Physical Size
Brick
Physical Size
Physical - UPS Module
Physical - UPS Module
Dimensions (WxHxD) (mm.) Weight (kg.)
230Vac
Input Voltage Range
90 x 190 x 235 2.1
2.8
Dimensions (WxHxD) (mm.)
3.0
2.1
2.8
3.0
Environmental
Weight (kg.)
100 x 84 x 309 2.7
3
Environmental
Operating Temperature
+ 32°F to 104° F / 0° C to 40° C
Operating Temperature
+ 32°F to 104° F / 0° C to 40° C
Operating Humidity
10% - 95% non-condensing
Operating Humidity
Operating Elevation
0-1000 meters
Operating Elevation
0-1000 meters
Storage Temperature
+5 °F to 113°F / -15°C to 45 °C
Storage Temperature
- 4°F to 122° F / -20° C to 50° C
Storage Relative Humidity Online Thermal Dissipation
10% - 95% 21 BTU/hr
30 BTU/hr
41 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
0% - 90% non-condensing
Storage Relative Humidity 21 BTU/hr
30 BTU/hr
41 BTU/hr
Online Thermal Dissipation
0% - 90% 30 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners
41 BTU/hr
15 BS SERIES
BRICS LCD SERIES EMI/RFI Noise Filtering
External Battery Charger**
The advanced EMI/RFI Noise Filtering helps to reduce electromagnetic and radio frequency interference problems. These filters smooth out minor current fluctuations and therefore improves picture and sound quality in audio/video systems.
The external battery charger is an add-on component, which allows you to charge an additional 4 AA/AAA batteries while utlising the UPS. *Note: AA/AAA batteries are NOT included.
The BS Series UPS provides home and office users peace of mind surge protection against spikes and power abnormalities. With EMI/RFI filters eliminating line noise or disturbances, it can supply reliable backup during power interruptions, brownouts and blackouts. The flexible mounting design allows placement options including horizontal, cabinet, and wall-mounted orientation.
The BRICs LCD Series UPS offers home and small office users clean and stable battery backup, with the RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. With Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. Flexible mounting design allows placement options including horizontal, cabinet, and wall-mounted orientation.
3
FR socket*
5 1 UK socket*
6
9
1. Power On/Off Switch 2. Power On Indicator 3. AC Outlets* 4. Communication Port to PC (USB) 5. Circuit Breaker Protection 6. Cable Collector
6
FR socket*
4
5
3
1. Power On/Off Switch 2. LCD Function Select Switch 3. LCD Display 4. Communication Protection Ports RJ11/RJ45 5. Battery Charger USB Port 6. AC Outlets* 7. Communication Port to PC (USB) 8. Circuit Breaker Protection 9. Cable Collector * =Other socket types available upon request
8 1
7 UK socket*
4
2
* =Other socket types available upon request
2
6
3 Technical Specifications Model Name
BS450E
BS650E
BS850E
General Standby
Energy Saving
Yes
UPS Topology
Line-interactive
Energy Saving
Yes
Voltage
165Vac - 280Vac
Input Frequency Range
Voltage
230Vac
Input Voltage Range
Schuko or UK
Output
10A
Plug Type
10A
Plug Type
50/60Hz ± 3Hz (Auto-sensing)
Rated Input Current
50/60Hz ± 3Hz (Auto-sensing)
Rated Input Current
192Vac - 263Vac
Input Frequency Range
Schuko or UK
Output
VA
650
850
1000
Watts
390
510
600
On Battery Waveform
VA
450
Watts
270
On Battery Waveform
650
850
On Battery Voltage
360
490
Automatic Voltage Regulation (AVR)
Simulated Sine Wave 230Vac ± 7%
Outlets - Total
On Battery Frequency
50/60Hz ± 1%
Outlet Type
Outlets - Total
6
Outlet Type
3
Transfer Time
4ms 6
Runtime at Full Load (min)
2
Battery Type
4ms 9
8
7
2
2
0.5
1
2
Battery Type
RBP0080
Replacement Battery Pack Quantity
Transfer Time
Runtime at Full Load (min)
Sealed Lead Acid
Battery Quantity
1
User Replaceable
Yes
Typical Recharge Time
8 Hours RBP0082
Yes
Runtime at Half Load (min)
Yes
Typical Recharge Time
3
USB Charging Ports
7
1
User Replaceable
3
7 Sealed Lead Acid
Battery Quantity
6 Schuko or FR or UK (UK x 4 + IEC x 2)
Battery
Battery Runtime at Half Load (min)
Yes 50/60Hz ± 1%
Outlets - Surge-Only Protected
3
Outlets - Surge-Only Protected
230Vac ± 10%
Outlets - Battery & Surge Protected
Schuko or FR or UK (UK x 4 + IEC x 2)
Outlets - Battery & Surge Protected
Simulated Sine Wave
On Battery Frequency
On Battery Voltage
Replacement Battery Pack RBP0081
1
8 Hours RBP0083
RBP0006
Replacement Battery Pack Quantity
1
Surge Protection & Filtering
Surge Protection & Filtering
Surge Suppression
Surge Suppression
405 Joules (L-N)
125 Joules (L-N)
Phone / Network Protection RJ11/RJ45
Management & Communications
'1-In, 1-Out (Combo)
Management & Communications
HID Compliant USB Port
Yes
LED Indicators
Power On, Using Battery
Audible Alarms
On Battery, Low Battery, Overload, Fault
LCD Control Panel
Yes
HID Compliant USB Port
Yes
Audible Alarms
PowerPanel® Personal Edition
Software
On Battery, Low Battery, Overload, Fault ®
PowerPanel Personal Edition
Software
Physical
Physical
Form Factor
Brick
Form Factor
Physical Size
Brick
Physical Size
Physical - UPS Module
Physical - UPS Module
Dimensions (WxHxD) (mm.)
160 x 114 x 271 2.6
3.1
Dimensions (WxHxD) (mm.) 3.4
Environmental
Weight (kg.)
359 x 162 x 113 5.6
6.6
6.8
Environmental
Operating Temperature
+ 32°F to 104° F / 0° C to 40° C
Operating Temperature
+ 32°F to 104° F / 0° C to 40° C
Operating Humidity
0% - 90% non-condensing
Operating Humidity
Operating Elevation
0-1000 meters
Operating Elevation
0-1000 meters
Storage Temperature
- 4°F to 122° F / -20° C to 50° C
Storage Temperature
- 4°F to 122° F / -20° C to 50° C
Storage Relative Humidity Online Thermal Dissipation
BR1000ELCD
230Vac
Input Voltage Range
Input
Weight (kg.)
BR850ELCD
Input
UPS Topology
Replacement Battery Pack
BR650ELCD
General
Technical Specifications Model Name
0% - 90% 14 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
18 BTU/hr
16
0% - 90% non-condensing
Storage Relative Humidity 21 BTU/hr
Online Thermal Dissipation
0% - 90% 71 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
72 BTU/hr
102 BTU/hr
17 VALUE SERIES
VALUE SOHO SERIES Local Socket
IEC Socket
The Value SOHO Series UPS features standard local sockets which are commonly used in household electric appliances such as lamps, standing fan, audio/video systems, LCD TV, etc., making it the best choice for home solution.
The Value Series UPS features IEC female sockets which are commonly used in electric making it the devices such as computers, workstations, laptops, printers, etc., the best choice for office solution.
The Value Series UPS offers home and small office users clean and stable battery backup. The inclusion of a RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The multifunction LCD readout provides immediate access to precise information about critical power/battery conditions.
The Value SOHO Series UPS offers home and small office users clean and stable battery backup. The inclusion of a RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. With Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The multifunction LCD readout provides immediate access to precise information about critical power/ battery conditions. 2
1
2
5
3
6
5
6
7
7
1 4
9
8 9
10 11
10
1. Power On/Off Switch 2. Power On Indicator 3. LCD Display 4. Display Select 5. Communication Port to PC (Serial) 6. Communication Port to PC (USB) 7. Phone/Fax/Modem/DSL Network Protection Ports 8. Circuit Breaker Protection 9. Battery Back up and Surge Protection Outlets 10. AC Input 11. Fuse Protection
4
5
2
4
5
FR socket*
6
6
1
1 8 3
3
8
7 7
1. Power On/Off Switch 2. LCD Display 3. Display Select 4. Communication Port to PC (Serial) 5. Communication Port to PC (USB)
9
6. Phone/Fax/Modem/DSL/Network Protection Ports 7. Battery Back up and Surge Protection Outlets* 8. Circuit Breaker Protection 9. AC Input
UK socket*
AS socket* *= Other socket types available upon request
Technical Specifications
Technical Specifications Model Name
VALUE600EI
VALUE800EI
VALUE1000EI
VALUE1200EILCD
VALUE1500EILCD
VALUE2200EILCD
Model Name
VALUE600ELCD
VALUE800ELCD
VALUE1000ELCD
VALUE1200ELCD
VALUE1500ELCD
VALUE2200ELCD
General
General UPS Topology
Line-Interactive
UPS Topology
Line-Interactive
Energy Saving
Yes
Energy Saving
Yes
Input
Input Voltage
Voltage
230Vac
Input Voltage Range 8A
50/60Hz ± 3Hz (Auto-sensing)
Rated Input Current
10A
Plug Type
165Vac - 280Vac
Input Frequency Range
50/60Hz ± 3Hz (Auto-sensing)
Rated Input Current
230Vac
Input Voltage Range
165Vac - 280Vac
Input Frequency Range
10A (Schuko or FR) or 8A (AS)
10A
Plug Type
IEC 320 C14
Schuko or NEMA
Output
Output VA
600
800
1000
Watts
360
480
550
On Battery Waveform
1200
1500
2200
720
900
1320
Outlets - Total
3
1500
2200
720
900
1320
230 Vac ± 10% Yes 50/60Hz ± 1% 2 (Schuko, FR) or 3 (AS)
4 Schuko or FR or AS
Outlets - Battery & Surge Protected
6
2 (Schuko, FR) or 3 (AS)
4
Transfer Time
4ms
1200 Simulated Sine Wave
Outlet Type
3
Transfer Time
550
Outlets - Total
6 IEC 320 C13
Outlets - Battery & Surge Protected
1000
On Battery Frequency
50/60Hz ± 1%
Outlet Type
800 480
Automatic Voltage Regulation (AVR)
Yes
On Battery Frequency
600 360
On Battery Voltage
230 Vac ± 10%
Automatic Voltage Regulation (AVR)
VA Watts On Battery Waveform
Simulated Sine Wave
On Battery Voltage
4ms
Battery
Battery Runtime at Half Load (min)
8
8
7
8
10
6
Runtime at Half Load (min)
8
8
7
8
10
6
Runtime at Full Load (min)
1
1
1
2
2
1
Runtime at Full Load (min)
1
1
1
2
2
1
Battery Type
Battery Type
Sealed Lead Acid
Battery Quantity
1
2
User Replaceable
-
Yes
Replacement Battery Pack
-
Replacement Battery Pack Quantity
-
RBP0084
RBP0085
RBP0086
2
Surge Protection & Filtering Surge Suppression
Battery Quantity
1
2
User Replaceable
-
Yes
Typical Recharge Time
8 Hours
Replacement Battery Pack
-
Replacement Battery Pack Quantity
-
RBP0084
-
HID Compliant USB Port
Yes
LCD Control Panel
Yes
HID Compliant USB Port
Power On, Using Battery
Audible Alarms
Yes Yes
Serial Port
-
Yes
Audible Alarms
On Battery, Low Battery, Overload, Fault PowerPanel® Personal Edition
Software
1-In, 1-Out
Management & Communications
Yes
Serial Port LED Indicators
RBP0086
405 Joules (L-N)
Phone / Network Protection RJ11/RJ45
LCD Control Panel
RBP0085 2
Surge Suppression
1-In, 1-Out
Management & Communications
On Battery, Low Battery, Overload, Fault PowerPanel® Personal Edition
Software Physical
Physical Form Factor
Form Factor
Tower
Tower
Physical Size
Physical Size
Physical - UPS Module
Physical - UPS Module Dimensions (WxHxD) (mm.)
100 x 140 x 300 4.6
5.2
Dimensions (WxHxD) (mm.)
140 x 180 x 326 5.5
11.2
13.2
14.5
Weight (kg.)
100 x 140 x 300 4.6
5.2
140 x 180 x 326 5.5
11.2
13.2
14.5
Environmental
Environmental Operating Temperature
Operating Temperature
+ 32°F to 104° F / 0° C to 40° C
Operating Humidity
0% - 90% non-condensing
Storage Relative Humidity 99 BTU/hr
- 4°F to 122° F / -20° C to 50° C
+ 5 °F to 113°F / -15°C to 45 °C
0% - 90%
10% - 95%
102 BTU/hr
109 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
0% - 90% non-condensing
10% - 95% non-condensing
Operating Elevation
0-1000 meters
Storage Temperature
+ 32°F to 104° F / 0° C to 40° C
Operating Humidity
10% - 95% non-condensing
Operating Elevation
Online Thermal Dissipation
Sealed Lead Acid
Surge Protection & Filtering
405 Joules (L-N)
Phone / Network Protection RJ11/RJ45
Weight (kg.)
18
167 BTU/hr
198 BTU/hr
0-1000 meters
Storage Temperature
- 4°F to 122° F / -20° C to 50° C
Storage Relative Humidity 225 BTU/hr
Online Thermal Dissipation
+5 °F to 113°F / -15°C to 45 °C
0% - 90% 99 BTU/hr
102 BTU/hr
10% - 95% 109 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
167 BTU/hr
198 BTU/hr
225 BTU/hr
19 INTELLIGENT LCD SERIES
PFC SINEWAVE SERIES Multifunction LCD Readout (Detailed Display)
Active PFC Power Supplies Compatible
Displays clear and consistent LCD readout of power/battery status including load, runtime, power and other information at a single push-ofa-button. Also, advanced settings can be configured to potential power problems in advance.
The PFC Sinewave Series protects equipment with Active PFC power supplies from unexpectedly shutdown or harmful stress when switching from AC power to UPS battery power.
Designed for small office/SOHO computers and home entertainment systems, the Intelligent LCD Series features “Best-In-Class” power protection with Automatic Voltage Regulation (AVR) line conditioning to maintain safe power levels for connected equipment without resorting to battery power. The RJ11/RJ45 port ensures phone, fax and modem lines are protected from surges and spikes. The multifunction LCD readout provides immediate access to detailed information relating to critical power/battery conditions.
1
FR socket*
3 6
4
7
8
UK socket* * =Other socket types available upon request
The PFC Sineware UPS with pure sine wave output safeguards mid-to high-end computer systems, servers and networking hardware that use conventional and Active Power Factor Correction (PFC) power supplies, while the RJ11/RJ45 port ensures phone, fax and modem lines are protected from surges. Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level , this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The multifunction LCd readout provides immediate access to detailed information relating to critical power/battery conditions.
1
5
2
1. Power On/Off Switch 2. Power On Indicator 3. LCD Display 4. LCD Display Toggle/Selected Switch 5. Communication Port to PC (USB) 6. Battery Back up and Surge Protection Outlets* 7. Full-Time Surge Protection Outlets* 8. Phone/Fax/Modem/DSL Network Protection Ports 9. AC Input 10. Circuit Breaker Protection
2
8
8 11
11
1. Power On/Off Switch 2. Power On Indicator 3. LCD Module Display 4. Display Switch 5. Silence Alarm Switch 6. Control Switch 7. Battery Charger USB Ports 8. Communication Protection Ports RJ11/RJ45 9. Battery and Surge Protected Outlets
12
3 4 5 6
7
9
14
10
9
10. Circuit Breaker 11. USB Port to PC 12. Serial Port to PC 13. AC Input
NEMA socket*
UK socket*
* =Other socket types available upon request
14
9
10
Technical Specifications Model Name
CP900EPFCLCD
CP1300EPFCLCD
CP1500EPFCLCD
General
Technical Specifications Model Name
CP1050EAVRLCD
CP1350EAVRLCD
CP1500EAVRLCD
UPS Topology
Line-Interactive
Energy Saving
Yes
Input Voltage
General UPS Topology
Line-Interactive
Energy Saving
Yes
230Vac
Input Voltage Range
165Vac - 265Vac
Input Frequency Range
50/60Hz ± 3Hz (Auto-sensing)
Rated Input current
Input Voltage
Plug Type
230Vac
Input Voltage Range Input Frequency Range
50/60Hz ± 3Hz (Auto-sensing)
Rated Input current
10A
Plug Type
10A Schuko
Schuko or UK or NEMA
Output
165Vac - 265Vac
VA
900
1300
1500
Watts
540
780
900
On Battery Waveform
Schuko or UK
Pure Sine Wave
On Battery Voltage
Output VA
1050
1350
1500
Automatic Voltage Regulation (AVR)
Watts
630
810
900
On Battery Frequency
On Battery Waveform
Outlets - Total
Simulated Sine Wave
On Battery Voltage Automatic Voltage Regulation (AVR)
Yes
On Battery Frequency
50/60Hz ± 1%
Outlets - Total
6
Outlet Type
230Vac ± 10% Yes 50/60Hz ±1% 6
6 (Schuko, UK) or 8 (NEMA)
Schuko
Schuko or UK (UK x 2 + IEC x 4) or NEMA
Outlets - Battery & Surge Protected
6
3 (UK) or 6 (Schuko) or 8 (NEMA)
Outlets - Surge-Only Protected
0
3 (UK) or 0 (Schuko, NEMA)
USB Charging Ports
-
Outlet Type
230Vac ± 10%
Yes
Transfer Time (Typical)
Schuko or FR or UK (UK x 2 + IEC x 4)
4ms
Battery
Outlets - Battery & Surge Protected
3
Outlets - Surge-Only Protected
3
Runtime at Half Load (min)
7
9
10
4ms
Runtime at Full Load (min)
1
2
3
Transfer Time
Battery Type
Battery Runtime at Half Load (min)
12
10
11
Battery Size
Runtime at Full Load (min)
3
2
3
Battery Quantity
Battery Type
Replacement Battery
Replacement Battery
Yes
Typical Recharge Time
RBP0064
RBP0015
Surge Suppression
Yes 8 Hours RBP0051
RBP0013
Surge Suppression
Yes 1-In, 1-Out (Combo)
Management & Communications
1-In, 1-Out (Combo)
LCD Control Panel
Management & Communications LCD Control Panel
Yes
HID Compliant USB Port
HID Compliant USB Port
Yes
Serial Port
LED Indicators
Power On, Wiring Fault
Audible Alarms
On Battery, Low Battery, Overload
Yes Yes -
Yes
LED Indicators
Power On
Audible Alarms
On Battery, Low Battery, Overload, Fault PowerPanel® Personal Edition
Software
PowerPanel® Personal Edition
Software
Physical
Physical Form Factor
Form Factor
Tower
Tower
Physical Size
Physical Size
Physical - UPS Module
Physical - UPS Module Dimensions (WxHxD) (mm.)
Dimensions (WxHxD) (mm.)
100 x 249 x 371 10.3
11.5
12.1
Weight (kg.)
100 x 230 x 275
100 x 265 x 370
6.6
9.5
10.9
Environmental
Environmental Operating Temperature
Operating Temperature
+ 32°F to 104° F / 0° C to 40° C
+ 32°F to 104° F / 0° C to 40° C
Operating Humidity
0% - 90% non-condensing
Operating Humidity
0% - 90% non-condensing
Operating Elevation
0-10000 feet (0-3000 meters)
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Relative Humidity Online Thermal Dissipation
RBP0016
405 Joules
Phone / Network Protection RJ11/RJ45
1215 Joules
Phone / Network Protection RJ11/RJ45
12V/8.5AH 2
Phone Protection RJ11
Surge Protection & Filtering
Weight (kg.)
12V/7AH
1
Surge Protection & Filtering
8 Hours RBP0012
12V/8.5AH
Typical Recharge Time
2
User Replaceable
Sealed Lead Acid
User Replaceable
Sealed Lead Acid
Battery Quantity
Storage Relative Humidity
0 - 95% 31 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
41 BTU/hr
61 BTU/hr
20
Online Thermal Dissipation
0 - 95% 31 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
41 BTU/hr
61 BTU/hr
The Smart Choice for Business
POWERPANEL® BUSINESS EDITION
REMOTE MANAGEMENT CAPABILITIES
PowerPanel® Business Edition is designed for enterprise-class applications, and gives power users and administrators the tools needed for full local/remote control. This industryleading software is capable of managing all power conditions of workstations and servers electrically-connected to the UPS on the network. Its features include automatic event logging/reporting, notifications, server shutdown and a user-friendly dashboard interface. It also allows for control customisation. These enterprise-level features give administrators the power to fully manage their UPS system and safeguard all connected equipment. PowerPanel® Business Edition software consists of Agent, Client and Center: The Agent - Monitors and configures the UPS through USB or serial connection. It logs UPS status and power events, and gracefully shuts down the hosted computer in response to the event of power failure. The Client - Establishes communication with the Agent and RMCARD, and generates actions when power event occurs. In the event of power failure, each Client will request that the hosted computer shuts down following notifications from the UPS, ensuring computers/devices powered by the UPS are be fully protected. The Center - Simultaneously monitors and controls multiple UPSs and computers with the Agent or Client installed via local network. It also logs events and results about commands for power management.
The Smart App UPS Systems feature remote network management capabilities via the PowerPanel® Business Edition software, an optional SNMP/ HTTP remote management card, and an optional ENVIROSENSOR. These management tools enable administrators to perform various operations including remote management, real-time monitoring, UPS configuration and scheduled server/workstations shutdowns. Our Smart App UPS systems and Remote Management Cards have achieved Cisco EnergyWise certified status. This means better support for other Energy-Wise-enabled entities and easier monitoring and control to achieve the best energy to achieve the best energy performance under the EnergyWise operation framework. Our Smart App UPS systems and Remote Management Card has been tested as compatible with Cisco EnergyWise 1.2.0. Go to www.cisco.com/go/compatibledisclaimer for complete disclaimer.
Remote Management Card
The Remote Management RMCARD is an optional extra that can be added to any Smart App UPS system for remote management and configuration of the UPS via standard web browsers or network management system (NMS).An administrator can access, monitor and perform remote management including UPS scheduled shutdown, startup and reboot; multiple alert notifications by e-mail, SMS, and SNMP trap; flexible event action setting. With its Hot-Swap Capability, the UPS system can remain 100% up and available for connected equipment whilst performing an RMCARD installation or replacement.
Product Features • Automatic file-savings, equipment shutdowns and OS hibernation
• Scheduled shutdowns, outlet control and restarts
• Multiple alert notification options: Email, SMS, Messenger, Alert message box
Servers/workstations protected by the UPS must be installed with PowerPanel® Business Edition to enjoy the extra value-added features as below: • UPS Status Notification Ability to define the recipients of event notifications that are on the same domain name as that of the protected servers/workstations.
• Real-time UPS monitoring • Remote management and configuration of UPS via Web Browser or NMS • Support auto-shutdown of servers/workstations to protect from data loss due to power failure • Hot-swappable (Plug-n-Play) • Schedule shutdown/start-up/reboot of the UPS via remote control • Event logging to track UPS operational history • Data logging for analysing power conditions • Event notifications via email, SMS and SNMP traps • Support TCP/IP, UDP, SNMPv1/HTTP, TELNET, NTP, DNS, SMTP protocols. (HW1.0 above). Support IPv6, HTTPs, SNMPv3, SSH protocols. (HW2.0 above) • SNMP MIB provided • Quick installation and user friendly interface • User upgradeable firmware via FTP • Security management provided • 10/100 Mbps Ethernet Compatible • Support ENVIROSENSOR to monitor temperature and humidity (*RMCARD 203/303 only) Remote Management Card
• Safe Shutdown Operation Configure graceful shutdown procedure for protected servers/workstations.
Model Remote Management Auto Shutdown Upgradable User Firmware Auto Event Notification Remote Scheduling Ethernet Speeds (Mbps) Auto Shutdown Clients ENVIROSENSOR Compatible
• User Programmable Command File In the event action section, we provide the flexibility to add your own command file to perform a specific/customisable action.
RMCARD202 RMCARD203 RMCARD302 RMCARD303 HTTP, NMS Workstations, Multiple Servers v E-mail, SMS, SNMP TRAP Shutdown, Startup, Reboot 10/100 50 N/A v N/A v
Environmental Sensor
The Environmental Sensor (ENVIROSENSOR) along with the selected Remote Management Card (RMCARD203/303) enables administrators to monitor real-time temperature and humidity readings to ensure all engineering devices are operating under appropriate environmental conditions. Via standard web browsers, administrators can easily monitor not only the ambient temperature and humidity but also the status of connected devices such as door alarms and smoke detector. When a defined event happens, the bundled RMCARD will send notifications to administrators for further offsite management, making it highly applicable for data centres, IT closets and other mission-critical installations.
Product Features
• Real-time environment monitoring • Remote management and configuration of the sensor via Web Browsers or NMS • Automatic event notifications via e-mail, SMS and SNMP traps • 4 input dry contacts application interface provided • Displays the name and location of the sensor and connected devices Environmental Sensor Model Name Measurement Range and Accuracy Temperature Humidity Communication Connection Port Input Contact Closure Physical Dimensions (L x W x H) (mm) Weight (g)
ENVIROSENSOR 0-70°C with accuracy ± 1°C 10-90RH with accuracy ± 2% RJ45 Port 4 59 x 45 x 29 41.5
ONSITE MANAGEMENT CAPABILITY ®
PowerPanel Business Edition for Virtual Environments As the trend of virtualisation has transformed the IT industry, the need for power protection comes from not only the physical investments but also virtual IT environments. With PowerPanel® Business Edition, enterprises using VMware ESX 4.1 or later versions can easily manage a UPS powering an ESX/ESXi host platform and virtual machines to monitor UPS status or perform a graceful unattended shutdown along with other advanced features. In addition, PowerPanel® Business Edition can also be installed on the following operation systems: • Windows 8 / 7 / Vista / XP • Windows Server 2012 / Server 2012 R2 / Server 2008 / Server 2008 R2 / Windows 2003 • Hyber-V Server 2012 / Server 2012 R2 • Citrix XenServer 5 or later versions • Linux builds or later versions, e.g. Red Hat Enterprise 5.1 / Fedora 7 / SUSE 10.1 / Debian 5.1 / Ubuntu 9.10
The RELAYIO500 Relay Control Card is a management solution, providing users with the ability for onsite UPS status monitoring and local device control via 5 output relays. In addition, the RELAYIO500 provides 1 input contact to perform a UPS shutdown in battery mode. Product Features
• Onsite UPS status monitoring & local device control • 5 contact closures indicating UPS status information • Perform onsite UPS shutdown on battery mode by contact closure input • Hot-swappable (Plug-n-Play) • Quick Installation • Dry Contact
Model Name RELAYIO500 Eletrical External S/D Voltage 7.5-12V Power Dissipation 1.35W Max (Default 12V input) Physical Dimensions (W x H x D) (mm) 41.8 x 14.2 x 81 Weight (g) 41.6 Environmental Operating Temperature 0 - 40°C Operating Humidity 0 to 95% Output Relay Rating Maximum Voltage Maximum Current 30VDC / 1255VAC 3A (per relay)
SMALL OFFICE
PRODUCT INDEX
Home & Home Office
OFFICE RACKMOUNT SERIES
31
● GreenPower UPS™ Technology ● Line-Interactive UPS Topology P. ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● Protected On / Off Switch ● Multifunction LCD Readout ● USB & Serial Connectivity Ports ● Hot-Swappable Battery Packs ● User-Replaceable Batteries ● SNMP / HTTP Remote Management Capability (Optional) ● PowerPanel® Business Edition Software
32
P.
PROFESSIONAL TOWER SERIES ● GreenPower UPS™ Technology ● Pure Sine Wave Output ● Line-Interactive UPS Topology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Auto-Restart / Auto-Charge ● Emergency Power Off (EPO) Port ● Multifunction LCD Readout ● Detachable LCD Panel ● USB & Serial Connectivity Ports ● User-Replaceable Batteries ● SNMP / HTTP Remote Management Capability (Optional) ● PowerPanel® Business Edition Software
HOME THEATER SYSTEM Smart App UPS Systems The Smart App UPS Systems provides an advanced level of protection and local / remote management software that supports mission-critical servers, telecom equipment, VOIP and internet infrastructure.
NETWORKING SERVERS WORKSTATIONS
CORPORATE DATA CENTER
37
ONLINE S SERIES ● Pure Sine Wave Output ● Rack / Tower Convertible Configuration* ● Critical Load Outlets ● Auto-Restart / Auto-Charge ● Multifunction LCD Readout ● USB & Serial Connectivity Ports ● Hot-Swappable Battery Packs ● Generator Mode Setting* ● Smart Battery Management ● PowerPanel® Business Edition Software
MEDIUM BUSINESS
PRODUCT INDEX
P.
● Online (Double Conversion) UPS Topology ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Emergency Power Off (EPO) Port ● Rotatable LCD Indicator* ● Extended Runtime (XL) Models* ● Online Output Voltage Setting* ● Economy Mode Setting ● SNMP / HTTP Remote Management Capability (Optional) *=Select models
ONLINE SERIES ● Pure Sine Wave Output ● Online (Double Conversion) UPS Topology ● Rack / Tower Convertible Configuration* ● EMI, RFI, Surge and Lightning Spike Protection ● Critical Load Outlets ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● Emergency Power Off (EPO) Port ● Multifunction LCD Readout ● Rotatable LCD Indicator* ● USB & Serial Connectivity Ports P. ● Extended Runtime (XL) Models ● Hot-Swappable Battery Packs ● Online Output Voltage Setting ● Generator Mode Setting ● Economy Mode Setting ● Smart Battery Management ● Fixed Charging Time with Extended Battery Pack ● Smart Fan Speed Control by Load Level ● SNMP / HTTP Remote Management Capability (Optional) *=Select models ● PowerPanel® Business Edition Software
41
PROFESSIONAL RACKMOUNT SERIES ● GreenPower UPS™ Technology ● Line-Interactive UPS Topology ● Automatic Voltage Regulation ● Critical Load Outlets ● Auto-Restart / Auto-Charge ● Protected On / Off Switch ● Rotatable LCD Indicator* ● Extended Runtime (XL) Models* ● User-Replaceable Batteries ● PowerPanel® Business Edition Software
● Pure Sine Wave Output ● Rack / Tower Convertible Configuration ● EMI, RFI, Surge and Lightning Spike Protection P. ● Phone / Fax / Modem / DSL / Network Protection ● Emergency Power Off (EPO) Port ● Multifunction LCD Readout ● USB & Serial Connectivity Ports ● Hot-Swappable Battery Packs ● SNMP / HTTP Remote Management Capability (Optional)
33
INDUSTRIAL EQUIPMENT
*= Select Models
FEATURE INDEX
FEATURE INDEX
MULTIFUNCTION LCD READOUT
AUTOMATIC VOLTAGE REGULATION (AVR)
AVR
AVR INCONSISTENT UTILITY POWER
CONSISTENT SAFE POWER
Multifunction LCD Readout
Compact display. Clear and consistent LCD readout of power/battery status including load, runtime, power and other information at a single push-of-abutton. Also, advanced settings can be configured to send alerts about potential power problems in advance.
Automatic Voltage Regulation (AVR)
Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains safe voltage for the connected equipment. AVR regulates high and low voltages and brings the power to a nominal 220/240 volts. This allows the UPS to maintain safe power levels without resorting to battery power, which significantly increases battery life and eliminates AC-DC power transfer when minor power fluctuations occur. It also reduces the chances of data loss, memory freezes, and system crashes.
Pure Sine Wave
PURE SINE WAVE
The Smart App UPS System provides mission-critical equipment with the highest level of line clarity- Pure Sine Wave. Distorted power and power anomalies, such as harmonics, high voltage transients and surges, while not as obvious as blackouts, can cause serious equipment performance and reliability problems. When incoming power is abnormal, the Smart App UPS models deliver smooth, sine wave battery output, which ensures equipment continues to operate optimally. Pure sine wave power is required for an increasing number of electronics that utilise Power Factor Corrections (PFC) power supplies.
Pure Sine Wave Benefits: • Servers: Operates at optimal specifications. • Electronic Equipment: Extends equipment life (such as VOIP, PBX) by running cooler and more efficient. • Telecommunications: Eliminates disrupting static, or hum in telecommunication equipment. • Sensitive Electronics: Operates properly and retains settings. • Commercial/Professional Audio/Video: Power noise is eliminated, removing lines in television screens and hum in sound systems.
Comparison Table OR Series PRT Series PR Series
Form Waveform Factor Rack Mount Simulated Sine Wave Tower Pure Sine Wave RM/T Pure Sine Wave
OLS Series
RM/T, Tower
Pure Sine Wave
v
-
OL Series
RM/T, Tower
Pure Sine Wave
v
-
Model
*= Select Models
LCD
AVR
v v v
v v v
Watt
600-1500 750-3000 750-6000
360-900 675-2700 500-4500
Load/Current Level AVR in Use* Overload Silent Mode Static Frequency Tolerance* Temperature (F and C)*
Runtime Battery in Use Battery Level Battery Shutdown Voltage* Battery Pack Numbers*
Output Frequency* Input Voltage Output Voltage Normal Operation Slew Rate* * = Select Models
LCD DISPLAY INFORMATION TABLE Simulated Sine Wave output produces a sine wave that is “stepped” or modified, while Pure Sine Wave output produces a sine wave that is similar to normal AC wall power.
Convertible Rack/Tower Configuration
The Smart App UPS units can be mounted in either Tower or Rack Mount form to make the most of your workstation space. This configuration option is especially important to give growing organizations, with changing requirements, maximum flexibility.
COMPARISON TABLE VA
LCD Display Information Table
Detailed display. The rotatable LCD readout showcases clear and consistent information about power/battery status including load, runtime, power, AVR and other information at a single push-of-a-button. Also, advanced settings can be configured to send alerts about potential power problems in advance.
Outlets
6 6/8/9 6/8/9/10 4/5/6/8/9/ 1000-10000 800-9000 Terminal Block 3/6/8/9/10/ 1000-10000 900-9000 Terminal Block
v v v
SNMP/ HTTP v v v
Home / SOHO / SMEs Home / SOHO / SMEs SMEs / Corporate / Industrial
v
v
v
SMEs / Corporate / Industrial
v
v
v
SMEs / Corporate / Industrial
RJ11/45
USB
Software
v *
v v v
v v
Designed for
CONVERTIBLE RACK/TOWER CONFIGURATION
FEATURE INDEX
FEATURE INDEX
HOT-SWAPPABLE, FRONT-LOAD BATTERIES Hot-Swappable, Front-Load Batteries UPS Extended Runtimes (XL) CyberPower extended runtime (XL) models feature convenient connectors that accept optional external battery packs to provide additional runtime. The external battery packs are easy to plug-in and can be “hot swapped” to ensure your business remains available during normal UPS maintenance.
UPS EXTENDED RUNTIMES (XL)
When performing battery maintenance, 100% uptime and availability of connected equipment is essential for all enterprises. The Smart App UPS features hot-swappable, front-loaded battery packs that are easy to install and ensure the uptime of connected equipment is maintained during normal battery maintenance. As long as utility power is present, the batteries can be hot-swapped without interrupting power to connected equipment. No special equipment is required for swapping batteries. Simply pull the front cover off and remove the internal battery pack holder with a Phillips screwdriver. Slide the front-loaded battery pack out of the UPS and install the new one back into the unit and secure.
Emergency Power Off (EPO) Port A CyberPower UPS system with an Emergency Power Off (EPO) port gives the capability to immediately power down all installed equipment from one single access point by activating a push button. EPO is an essential feature for many applications in industrial, telecommunications and the IT industry to protect against water damage, excessive heat, security breaches, or catastrophic failures.
EPO
EMERGENCY POWER OFF (EPO) PORT
Critical Load Outlets The inclusion of critical load outlets means the transfer of battery power can be reserved to specified outlets during a power overload and administrators can easily prioritise and protect the most valuable equipment and data. Equipment connected to critical load outlets will continue functioning on battery power when utility power is not adequate to power all connected equipment.
CRITICAL LOAD OUTLETS
RJ11/RJ45 PROTECTION
RJ11/RJ45 Protection The RJ11/RJ45 port is designed to protect data lines and communication equipment from AC transients caused by surge, electrostatic discharge and other power abnormalities.
31 OFFICE RACKMOUNT SERIES
PROFESSIONAL TOWER SERIES Detachable LCD Panel
Hot-Swappable Battery
This unique feature can be removed and relocated up to 4.5 feet from the unit so that IT managers can easily access the UPS systems in data centres for quick and efficient power supply management, regardless of location.
All Smart App UPS feature hot-swappable batteries which can be easily installed or unplugged during normal battery maintenance without interruption to the UPS operation.
The Office Rackmount Series offers users, from SMEs to corporate data centres, clean and stable power supply with the featured RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. With Automatic Voltage Regulation (AVR) stabilizes the AC signal and maintains stable voltage, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The optional SNMP/HTTP Remote Management Capability enables remote management and control of the system via a standard web browser.
2
1
4
3
6
7
8
9
10
Model Name OR600ELCDRM1U
OR1000ELCDRM1U
OR1500ELCDRM1U
General UPS Topology
Line-Interactive
Energy Saving
GreenPower UPS™ Bypass Technology
Input Voltage Input Voltage Range
1. Power Switch/Power On Indicator 2. Online Indicator 3. On Battery Indicator 4. Fault 5. Replace Battery Indicator 6. Tab/Status Button 7. Enter/Setup Button 8. Up/Control Button 9. Down/Test Button 10. Esc/Logs Button 11. Battery and Surge Protected Outlets 12. Communication Port to PC (USB)
12
1 2 4 6
Setup
Tab
Enter
7
Control
Test
Logs
230Vac 175Vac - 255Vac
Input Frequency Range
13. Communication Port to PC (Serial) 14. EPO (Emergency Power Off) Port 15. SNMP/HTTP Network Slot 16. Circuit Breaker 17. AC Input
160Vac - 270Vac
PR750ELCD
11
▲ PR750ELCD
IEC 320 C14
Line-Interactive GreenPower UPS™ Bypass Technology
Energy Star Qualified
Yes
Active PFC Compatible
Yes
600
1000
1500
360
600
900
Simulated Sine Wave 230Vac ± 10%
Automatic Voltage Regulation (AVR)
10A
16A
IEC 320 C14
IEC 320 C20
Output VA
750
1000
1500
2200
3000
Watts
675
900
1350
1980
2700
Sine Wave 230Vac ± 5%
Automatic Voltage Regulation (AVR)
6
Outlet Type
163Vac - 286Vac 50/60Hz ± 3Hz (Auto-sensing)
On Battery Voltage
50/60Hz ± 1%
Outlets - Total
Yes
On Battery Frequency
IEC 320 C13
50/60Hz ± 1%
Overload Protection
Outlets - Battery & Surge Protected
4
Outlets - Total
Outlets - Surge-Only Protected
2
Outlet Type
On Utility: Circuit Breaker & Internal circuitry limiting / On Battery: Internal Current Limiting 6
8
9
IEC 320 C13
(8) IEC 320 C13, (1) IEC 320 C19
USB Charging Ports
N/A
Outlets - Battery & Surge Protected
Rated Power Factor
0.6
Outlets - Surge-Only Protected
Transfer Time (Typical)
4ms
Rated Power Factor
0.9
Transfer Time
4ms
Battery Runtime at Half Load (min)
12
14
11
Runtime at Full Load (min)
4
4
3
Battery Type
Sealed Lead Acid 6V/9AH 2
User Replaceable Hot-Swappable Typical Recharge Time
6V/7AH
6V/9AH
4
4
12
14
17
27
13
4
4
5
10
5
Battery Type Battery Size User Replaceable
Sealed Lead Acid 12V/7AH
12V/12AH
12V/17AH
RBP0026
Yes Quick Charge: 3 Hours, ECO Mode: 8 Hours RBP0014
RBP0065
RBP0023
1-In, 1-Out (Combo)
RBP0024
Surge Suppression
405 Joules
Management & Communications
LCD Control Panel
Yes
LCD Control Panel
Yes
HID Compliant USB Port
Yes
Detachable LCD Control Panel Option
Yes
Serial Port
Yes
HID Compliant USB Port
Yes
LED Indicators
Power On, Wiring fault
Audible Alarms
On Battery, Low Battery, Overload
Software SNMP / HTTP Remote Monitoring
Serial Port
Yes
Emergency Power Off (EPO) Port
Yes
PowerPanel® Business Edition
LED Indicators
Power On, On Line, On Battery, Wiring fault, Replace Battery
Yes, with optional RMCARD202/203
Audible Alarms
On Battery, Low Battery, Overload, Fault
Physical
PowerPanel® Business Edition
Software
Form Factor
Rack
SNMP / HTTP Remote Monitoring
Physical Size
Yes, with optional RMCARD202/203
Physical
Physical - UPS Module
Form Factor 430 x 44 x 235
433 x 44 x 389
433 x 44 x 485
8.1
16.1
19.4
Installed Rack Height
1U
Physical - UPS Module Weight (kg.)
+ 32°F to 104° F / 0° C to 40° C
Operating Temperature Operating Humidity
0% - 90% non-condensing
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C 20 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
24 BTU/hr
138 x 162 x 349
170 x 221 x 432
170 x 221 x 432
196 x 432 x 513
196 x 432 x 513
12.3
18.9
25.1
52.6
55.5
137 BTU/hr
205 BTU/hr
Environmental Operating Temperature
0 - 95%
Storage Relative Humidity
Tower
Physical Size Dimensions (WxHxD) (mm.)
Environmental
Online Thermal Dissipation
RBP0024
Surge Protection & Filtering
Management & Communications
Weight (kg.)
12V/17AH 4
Yes
Typical Recharge Time Replacement Battery
12V/17AH
2
Hot-Swappable
1030 Joules
Phone / Network Protection RJ11/RJ45
9 0
Runtime at Half Load (min)
Yes
Surge Protection & Filtering Surge Suppression
8
Runtime at Full Load (min)
Battery Quantity
RBP0025
6
Battery
Yes 8 Hours RBP0019
PR3000ELCD
230Vac
On Battery Waveform
Yes
On Battery Frequency
PR2200ELCD
160Vac - 280Vac
Rated Input current
Watts On Battery Voltage
PR1500ELCD
Energy Saving
Plug Type
On Battery Waveform
PR1000ELCD
Input Frequency Range
VA
Dimensions (WxHxD) (mm.)
17
▲ PR1000ELCD PR1500ELCD ▲ PR2200ELCD/PR3000ELCD
UPS Topology
Input Voltage Range
10A
Plug Type
Replacement Battery
16
17
General
Voltage
Output
Battery Quantity
16
16
17
Input
50/60Hz ± 3Hz (Auto-sensing)
Rated Input current
Battery Size
11
11
9
12
15
15
10 11
Esc
13
15
12 13 14
14
3 5
8 Status
13
14
Technical Specifications
Technical Specifications Model Name
The Professional Tower Series UPS provides an advanced level of power protection to servers, telecom equipment, VOIP, Internet infrastructure and other mission-critical applications. Featuring Pure Sine Wave output and Automatic Voltage Regulation (AVR) that stabilises the AC signal and maintains stable voltage, it enables the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The optional SNMP/HTTP Remote Management Capability enables remote management and control of the system via a standard web browser.
1. Power On/Off Switch 2. LCD Display 3. LCD Readout Toggle Button 4. Phone/Fax/Modem/DSL Network Protection Ports 5. Circuit Breaker Protection 6. Battery Backup and Surge Protection Outlets 7. Surge Protection Outlets 8. Expansion Port 9. Communication Port to PC (USB & Serial) 10. AC Input
5
32
32°F to 104° F / 0° C to 40° C
Operating Humidity
0% - 90% non-condensing
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Relative Humidity 24 BTU/hr
Online Thermal Dissipation
0 - 95% 75 BTU/hr
102 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
113 BTU/hr
33 PROFESSIONAL RACKMOUNT SERIES
PROFESSIONAL RACKMOUNT SERIES
34
Pure Sine Wave
Pure Sine Wave output produces a true sine wave that is similar to normal AC wall power, that which ensures continuous optimal operation. UPS with Pure Sine Wave are designed for electronics utilising Active PFC power supplies or other devices that require pure sine wave for proper function.
The Professional Rackmount Series UPS provides an advanced level of power protection to servers, telecom equipment, VOIP, Internet infrastructure and other mission-critical applications. Featuring Pure Sine Wave output and Automatic Voltage Regulation (AVR) that stabilises the AC signal and maintains a safe voltage, it allows the UPS to maintain safe power levels for connected equipment without resorting to battery power. With the optional Extended Runtime (XL) battery packs, the UPS backup time can be extended to maximize workflow flexibility. It can be configured in either Tower (T) or Rack Mount (RM) form to make the most of your workspace.
Technical Specifications Model Name
PR750ELCDRT1U
PR1000ELCDRT1U
PR1000ELCDRT2U
PR1500ELCDRT2U
PR2200ELCDRT2U
PR3000ELCDRT2U
General
Technical Specifications Model Name
PR1000ELCDRTXL2U
PR1500ELCDRTXL2U
PR2200ELCDRTXL2U
PR3000ELCDRTXL2U
PR5000ELCDRTXL5U
PR6000ELCDRTXL5U
General
UPS Topology
Line-Interactive
UPS Topology
Line-Interactive
Energy Saving
GreenPower UPS™ Bypass Technology
Energy Saving
GreenPower UPS™ Bypass Technology
Active PFC Compatible
Yes
Active PFC Compatible
Input
Yes
Input
Voltage
220/230/240Vac
Voltage
220/230/240Vac
Input Voltage Range
160Vac – 288Vac
Input Voltage Range
160Vac – 288Vac
Input Frequency Range
50/60Hz ± 0.1Hz
Rated Input Current
Input Frequency Range
10A
Plug Type
16A
IEC 320 C14
IEC 320 C20
50/60Hz ± 0.1Hz
Rated Input Current
10A
Plug Type
Output
16A
IEC 320 C14
32A
IEC 320 C20
Terminal Block
Output
VA
750
1000
1000
1500
2200
3000
VA
1000
1500
2200
3000
5000
6000
Watts
500
670
700
1000
1600
2250
Watts
750
1125
1650
2400
4000
4500
On Battery Waveform
Sine Wave
On Battery Voltage Automatic Voltage Regulation (AVR)
6 IEC 320 C13
Outlets - Battery & Surge Protected
IEC 320 C13
10
IEC 320 C13
6
IEC 320 C13
8
Outlets - Critical Load
2
Outlets - Non-Critical Load (NCL)
4
(1) IEC320 C19, (9) IEC320 C13
On Utility: Circuit Breaker / On Battery: Internal Circuitry Limiting
Outlets - Total Outlet Type
10 IEC 320 C13
9 (1) IEC320 C19, (9) IEC320 C13
IEC 320 C13
(1) IEC320 C19, (8) IEC320 C13
11 (8) IEC 320 C13, (2) IEC 320 C19, (1) Terminal Block
(8) IEC 320 C13, (2) IEC 320 C19, (1) Terminal Block
10
Outlets - Battery & Surge Protected
10
9
11
4
Outlets - Critical Load
4
3
6
6
Transfer Time
50/60Hz ± 0.1%
Overload Protection
8 IEC 320 C13
Yes
On Battery Frequency
On Utility: Circuit Breaker / On Battery: Internal Circuitry Limiting
Outlets - Total
220/230/240Vac ± 5%
Automatic Voltage Regulation (AVR)
50/60Hz ± 0.1%
Overload Protection
Sine Wave
On Battery Voltage
Yes
On Battery Frequency
Outlet Type
On Battery Waveform
220/230/240Vac ± 5%
Outlets - Non-Critical Load (NCL)
4ms
6
5
Transfer Time
Battery
4ms
Battery
Runtime at Half Load (min)
23
14
32
18
16
8
Runtime at Half Load (min)
40
22
13
8
31
28
Runtime at Full Load (min)
7
5
11
6
6
3
Runtime at Full Load (min)
18
8
5
3
12
10
Battery Type Battery Size Battery Quantity
Sealed Lead-Acid
Battery Type
6V/9AH
6V/9AH
12V/7AH
12V/7AH
12V/9AH
12V/9AH
4
4
4
4
4
4
User Replaceable Hot-Swappable Typical Recharge Time Extended Battery Module
User Replaceable
Yes
Hot-Swappable
12V/9AH
12V/9AH
12V/9AH
12V/9AH
12V/9AH
12V/9AH
4
4
4
4
16
16
Yes Yes
Typical Recharge Time
-
BPE48V75ART2U
RBP0027
Battery Quantity
Yes 6 Hours
Replacement Battery
Battery Size
Sealed Lead-Acid
RBP0030
RBP0037
RBP0040
Surge Protection & Filtering
6 Hours
Extended Battery Module
BPE48V75ART2U
Replacement Battery
BPL48V75ART2U RBP0040
RBP0044 / RBP0045
Surge Protection & Filtering
Surge Suppression
810 Joules
Phone Protection RJ11
Surge Suppression
-
Yes
Phone / Network Protection RJ11/RJ45
810 Joules
Phone Protection RJ11
1-In, 1-Out (Combo)
Yes
Phone / Network Protection RJ11/RJ45
Management & Communications
1-In, 1-Out (Combo)
Management & Communications
LCD Control Panel
Yes
LCD Control Panel
Yes
HID Compliant USB Port
Yes
HID Compliant USB Port
Yes
Serial Port
Yes
Serial Port
Yes
Emergency Power Off (EPO) Port
Yes
Emergency Power Off (EPO) Port
Yes
LED Indicators
Power On
LED Indicators
Power On
Audible Alarms
On Battery, Low Battery, Overload
Audible Alarms
On Battery, Low Battery, Overload
PowerPanel® Business Edition
Software SNMP / HTTP Remote Monitoring
SNMP / HTTP Remote Monitoring
Physical
Yes, with optional RMCARD202/203
Physical
Form Factor
Rack
Form Factor
Physical Size
Rack
Physical Size
Physical - UPS Module
Physical - UPS Module
Dimensions (WxHxD) (mm.) Weight (kg.)
PowerPanel® Business Edition
Software
Yes, with optional RMCARD202/203
430 x 44 x 490 17.6
Installed Rack Height
433 x 88 x 388 18
25.5
433 x 88 x 480
27
1U
30
37
2U
Dimensions (WxHxD) (mm.) Weight (kg.)
433 x 88 x 480 30.8
Installed Rack Height
Environmental
433 x 88 x 630
34.5
34.9
42
2U
103.5 5U
Environmental
Operating Temperature
32 °F to 104 °F / 0 °C to 40 °C
Operating Temperature
32 °F to 104 °F / 0 °C to 40 °C
Operating Humidity
0% - 95% non-condensing
Operating Humidity
0% - 95% non-condensing
Operating Elevation
0-10000 feet (0-3000 meters)
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Relative Humidity Online Thermal Dissipation
433 x 220 x 645 101.5
0 - 95% 49 BTU/hr
72 BTU/hr
64 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
Storage Relative Humidity 139 BTU/hr
218 BTU/hr
337 BTU/hr
Online Thermal Dissipation
0 - 95% 99 BTU/hr
170 BTU/hr
228 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
385 BTU/hr
410 BTU/hr
490 BTU/hr
35 PROFESSIONAL RACKMOUNT SERIES 3
4 1
PROFESSIONAL RACKMOUNT SERIES
2
▲ PR750ELCDRT1U/PR1000ELCDRT1U
▲PR1000ELCDRTXL2U/PR1500ELCDRTXL2U/PR2200ELCDRTXL2U/ PR3000ELCDRT2U/PR3000ELCDRTXL2U
5
18 3
11 13 15
17
10 6
8
16
1 2 4
▲PR1000ELCDRTXL2U/PR1500ELCDRTXL2U
8
10
6
▲PR2200ELCDRTXL2U/PR3000ELCDRT2U
▼ PR2200ELCDRT2U
5 5
11 15
PR1000ELCDRT2U/ ▼ PR1500ELCDRT2U
17 11 15
▼ PR3000ELCDRTXL2U
18
6
17 10
PR1000ELCDRT2U/ PR1500ELCDRT2U/ ▼ PR2200ELCDRT2U
6
13
14
3
1
5
2
7 1. Power On/Off Switch 2. Power On Indicator 3. Multifunction LCD Readout 4. LCD Readout Toggle Button 5. Battery Backup, Surge Protected & AVR Protected Outlets (Critical/Non-Critical)
12
18 13 14
12 4
▼ PR5000ELCDRTXL5U/PR6000ELCDRTXL5U
16
6. AC Inlet 7. Output Terminal Block 8. Output Circuit Breaker 9. Input Terminal Block 10. Input Circuit Breaker 11. USB Port to PC
8 10
9
17
18 16
13
11 15
14
12
12. Surge Protected Communication Ports - RJ11/RJ45 13. Serial Port/Serial Port I (Primary) 14. Serial Port II (Secondary) 15. EPO (Emergency Power Off) Port 16. Extended Runtime (XL) Battery Pack Connector 17. SNMP/HTTP Network Slot 18. Ground Stud
External Battery Packs Model Name
BPE48V75ART2U
BPL48V75ART2U
220-240V
100-240V
60A
100A
General Voltage Amperage
E
▼ BPE48V75ART2U
C
B
A
D
Battery Battery Type
Sealed Lead-Acid
Battery Size Battery Quantity
12V/9AH 8
12
Typical Recharge Time
6 Hours
Built-in Charger
Yes
Expansion Ready (Daisy-chain)
Yes
Physical Dimensions (WxHxD) (mm.) Weight (kg.)
433 x 88 x 480
433 x 88 x 630
31.2
45.3
Environmental Operating Temperature Operating Humidity
32 °F to 104 °F / 0 °C to 40 °C 0% - 90% non-condensing
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Relative Humidity
0% - 95% non condensing
Compatible Models Compatible Models
PR3000ELCDRT2U PR1000ELCDRTXL2U PR1500ELCDRTXL2U PR2200ELCDRTXL2U
PR3000ELCDRTXL2U PR5000ELCDRTXL2U PR6000ELCDRTXL2U
F
G
B
A. On-board User-Replaceable Fuse Cover B. External Battery Pack Input Socket C. External Battery Pack Output Socket D. DC Circuit Breaker*
C
▲ BPL48V75ART2U
E . AC Circuit Breaker F . AC Output Outlet G . AC Input Inlet * = Select Models
36
37 ONLINE S SERIES
ONLINE S SERIES Online Double Conversion Topology
Ultimate Protection Online Double Conversion Topology
Online Double Conversion Topology provides an extra layer of insulation from power problems, achieved by continuously operating off battery power and having zero transfer time during power outages. It also stabilises output frequency and voltage, eliminates any line noise that may be apparent in industrial settings or when operating off generator power.
OLS1000E
OLS1500E
OLS2000E
OLS3000E
OLS1000EXL
OLS1500EXL
Double-Conversion
Energy Saving
ECO Mode Efficiency > 95%
OLS2000EXL
OLS3000EXL
Yes
160Vac - 300Vac
190Vac - 300Vac
160Vac - 300Vac
190Vac - 300Vac
40Hz - 70Hz
Rated Input Current
10A
16A
10A
Input Power Factor
0.98
Cold Start
Yes
Plug Type
IEC C14
IEC C14
1500
2000
3000
Watts
800
1200
1600
2400
On Battery Waveform
Outlets - Total Outlet Type
OLS3000ERT2U
OLS1000ERTXL2U
Double-Conversion ECO Mode Efficiency > 95%
OLS1500ERTXL2U
OLS2000ERTXL2U
OLS3000ERTXL2U
Yes
Voltage
230Vac
Input Voltage Range
160Vac - 300Vac
190Vac - 300Vac
160Vac - 300Vac
10A
16A
1500
2000
3000
800
1200
1600
2400
IEC C20
VA
1000
1500
2000
3000
1000
1500
2000
3000
800
1200
1600
2400
800
1200
1600
2400
Overload Protection
Sine Wave 208, 220, 230, 240Vac (Configurable)
On Battery Frequency
4
5
6
4
4
5
6
(2+2) IEC320 C13, (1) Terminal Block
(1) IEC320 C19, (2+2) IEC320 C13, (1) Terminal Block
IEC320 C13
IEC320 C13
(2+2) IEC320 C13, (1) Terminal Block
(1) IEC320 C19, (2+2) IEC320 C13, (1) Terminal Block
IEC C20
Watts
AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120% Bypass Mode: Warning only @ 130%>Load>105%, Shutdown immediately @ Load>130%
IEC320 C13
IEC C14
Output
On Battery Voltage
4
16A
Yes IEC C14
On Battery Waveform
IEC320 C13
10A 0.98
Plug Type
1000
190Vac - 300Vac
40Hz - 70Hz
Cold Start
IEC C20
208, 220, 230, 240Vac (Configurable)
Overload Protection
OLS2000ERT2U
Energy Saving
50/60Hz ± 0.5% (Auto-Sensing or Configurable)
On Battery Frequency
OLS1500ERT2U
UPS Topology
Rated Input Current
Sine Wave
On Battery Voltage
OLS1000ERT2U
Input Power Factor
IEC C20
1000
Model Name
Input Frequency Range
16A
Output VA
Technical Specifications
Input
230Vac
Input Voltage Range
*=Select Models
Active PFC Compatible
Input
Input Frequency Range
Smart Battery Management (SBM) is an intelligent management procedure that can prevent premature wear-out of the batteries. By charging the batteries in several phases with different current levels, SBM can eliminate over-charged situations. Furthermore, when combined with the temperature compensation feature, SBM dramatically reduces the deterioration of battery capacity caused by exhaust heat during a working cycle.
General
UPS Topology
Voltage
Smart Battery Management (SBM)
The Economy Mode Setting increases the operating efficiency of UPS, by up to 95% under ECO mode, while also generating less BTU heat output and reducing operating energy costs.
General
Active PFC Compatible
By selecting the generator as an input power source, the Online Series will co-exist with household power generator, whilst ensuring the output power quality without sacrificing any protection.
Economy Mode Setting
Technical Specifications Model Name
Generator Mode Setting*
CyberPower Smart App Online Systems provide continuous, consistent and clean Pure Sine Wave power to mission-critical equipment, regardless of the incoming power conditions. The Online Double Conversion Topology provides an extra layer of insulation from power problems which is achieved by continuously operating off battery power and having zero transfer time during power outages. It also stabilises output frequency and voltage and eliminates any line noise that may be apparent in industrial settings or when operating off generator power.
Featuring Online Double Conversion UPS topology, the Online S Series UPS provides the highest level of power protection and a guaranteed quality power supply to demanding businesses that value manageability and performance. This series features numerous engineering excellences including Economy Mode Setting, Smart Battery Management and Generator Mode Setting, all to further enhancing its capability. With its zero transfer time, the Online S Series ensures continuous, consistent and clean Pure Sine Wave power to all mission-critical equipment.
Outlets - Total Outlet Type
50/60Hz ± 0.5% (Auto-Sensing or Configurable) AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120% Bypass Mode: Warning only @ 130%>Load>105%, Shutdown immediately @ Load>130% 6
6
8
9
6
6
8
9
(3+3) IEC320 C13
(3+3) IEC320 C13
(4+4) IEC320 C13
(1) IEC320 C19, (4+4) IEC320 C13
(3+3) IEC320 C13
(3+3) IEC320 C13
(4+4) IEC320 C13
(1) IEC320 C19, (4+4) IEC320 C13
Outlets - Battery & Surge Protected
4
4
5
6
4
4
5
6
Outlets - Battery & Surge Protected
6
6
8
9
6
6
8
9
Outlets - Critical Load
4
4
5
6
4
4
5
6
Outlets - Critical Load
6
6
8
9
6
6
8
9
Rated Power Factor
0.8
Rated Power Factor
0.8
Harmonic Distortion
THD < 3% at Linear Load, < 5% at Non-linear Load
Harmonic Distortion
THD < 3% at Linear Load, < 5% at Non-linear Load
Transfer Time
0ms
Transfer Time
Battery
0ms
Battery
Runtime at Half Load (min)
16
14
16
14
Depends on external batteries
Runtime at Half Load (min)
16
14
16
14
Depends on external batteries
Runtime at Full Load (min)
6
5
6
5
Depends on external batteries
Runtime at Full Load (min)
6
5
6
5
Depends on external batteries
12V/9AH
12V/7AH
12V/9AH
12V/7AH
Battery Type Battery Size
Sealed Lead-Acid 12V/7AH
Battery Quantity
12V/9AH
3
Battery Type
12V/7AH
12V/9AH
6
12V/7AH
12V/9AH
3
User Replaceable
6 Depends on external batteries
BPSE36V45A
12V/9AH
3
12V/7AH
BPSE72V45A
BPSE36V45A
BPSE72V45A
5 Hours
Depends on external batteries Yes
Extended Battery Module
440 Joules
Phone Protection RJ11
BPSE36V45ART2U
BPSE72V45ART2U
BPSE36V45ART2U
Surge Suppression
Yes
Phone / Network Protection RJ11/RJ45
BPSE72V45ART2U
440 Joules
Phone Protection RJ11
1-In, 1-Out
Yes
Phone / Network Protection RJ11/RJ45
Management & Communications
1-In, 1-Out
Management & Communications
LCD Control Panel
Yes
LCD Control Panel
Yes
HID Compliant USB Port
Yes
HID Compliant USB Port
Yes
Serial Port
Yes
Serial Port
Yes
Emergency Power Off (EPO) Port
Yes
Emergency Power Off (EPO) Port
Yes
Audible Alarms
Audible Alarms ®
PowerPanel Business Edition
Software SNMP / HTTP Remote Monitoring
Yes Yes ®
PowerPanel Business Edition
Software
Yes, with optional RMCARD302 / RMCARD303
SNMP / HTTP Remote Monitoring
Physical
Yes, with optional RMCARD302 / RMCARD303
Physical
Form Factor
Tower
Form Factor
Physical Size
Rack/Tower
Physical Size
Physical - UPS Module
Physical - UPS Module
Dimensions (WxHxD) (mm.)
151 x 225 x 394 13.1
196 x 337 x 416 15.3
Installed Rack Height
23.8
28.2
-
-
Dimensions (WxHxD) (mm.)
-
Weight (kg.)
-
438 x 88 x 430 13.2
438 x 88 x 610 14.6
Installed Rack Height
Physical - Power Module
21.2
27.6
-
2U
-
Physical - Power Module
Dimensions (WxHxD) (mm.)
-
Weight (kg.)
-
Power Module Rack Height
-
151 x 225 x 394 7.7
196 x 337 x 416 7.8
12.2
12.6
-
Physical - Battery Module
Dimensions (WxHxD) (mm.)
-
Weight (kg.)
-
Power Module Rack Height
-
438 x 88 x 430 8.4
438 x 88 x 610 8.5
11.6
12
2U
Physical - Battery Module
Dimensions (WxHxD) (mm.)
151 x 225 x 394 17.2
196 x 337 x 416 17.2
34.2
151 x 225 x 394 34.2
Battery Module Rack Height
17.2
196 x 337 x 416 17.2
34.2
Dimensions (WxHxD) (mm.) 34.2
-
Weight (kg.)
438 x 88 x 430 24.2
438 x 88 x 610 24.2
34.7
438 x 88 x 430 34.7
Battery Module Rack Height
Environmental
24.2
438 x 88 x 610 24.2
34.7
34.7
420 BTU/hr
666 BTU/hr
1126 BTU/hr
2U
Environmental
Operating Temperature
32 °F to 104 °F / 0 °C to 40 °C
Operating Temperature
32 °F to 104 °F / 0 °C to 40 °C
Operating Humidity
20% ~ 90% non-condensing
Operating Humidity
Operating Elevation
0-5000 feet (0-1500 meters)
Operating Elevation
0-5000 feet (0-1500 meters)
Storage Temperature
-4 °F to 122 °F / -20 °C to 50 °C
Storage Temperature
-4 °F to 122 °F / -20 °C to 50 °C
Storage Relative Humidity Online Thermal Dissipation
12V/9AH 6
Surge Protection & Filtering
Surge Suppression
Weight (kg.)
12V/7AH
3 Yes
Smart Battery Management (SBM) Mode
Surge Protection & Filtering
12V/9AH
6
Typical Recharge Time
Yes
Extended Battery Module
12V/7AH
User Replaceable
5 Hours
Smart Battery Management (SBM) Mode
Battery Size Battery Quantity
Yes
Typical Recharge Time
Weight (kg.)
38
10% to 90% 342 BTU/hr
420 BTU/hr
666 BTU/hr
1126 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
20% ~ 90% non-condensing
Storage Relative Humidity 342 BTU/hr
420 BTU/hr
666 BTU/hr
1126 BTU/hr
Online Thermal Dissipation
10% to 90% 342 BTU/hr
420 BTU/hr
666 BTU/hr
1126 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
342 BTU/hr
39 ONLINE S SERIES
ONLINE S SERIES
40
Technical Specifications Model Name
OLS6000E
OLS6000EXL
OLS10000E
OLS10000EXL
UPS Topology
Double-Conversion
Energy Saving
ECO Mode Efficiency > 96%
Active PFC Compatible
7
1
General
220-240Vac
Input Voltage Range
176Vac - 276Vac
Input Frequency Range
9
11 3 2
Yes
Input Voltage
6
8
3 2
1 5
50/60Hz ± 10% (Auto-sensing)
Rated Input Current
27.3A
45.5A
Input Power Factor
0.99
Cold Start
Yes
Plug Type
Terminal Block
12
Output VA
6000
10000
Watts
5400
9000
On Battery Waveform
Outlets - Total
Terminal Block
Rated Power Factor
0.9
Harmonic Distortion
THD < 2% at Linear Load, < 5% at Non-linear Load
Transfer Time
7 6 ▲OLS1000ERT2U/ERTXL2U/OLS1500ERT2U/ERTXL2U
7
Runtime at Half Load (min)
15
Depends on external batteries
11
Depends on external batteries
5
Depends on external batteries
4
Depends on external batteries
12V/9AH
-
Sealed Lead-Acid
Battery Quantity Typical Recharge Time
-
20
-
20
-
Depends on external batteries
7 Hours
Depends on external batteries
Yes
Extended Battery Module
BPSE240V47A
Management & Communications LCD Control Panel
Yes
HID Compliant USB Port
Yes
Serial Port
Yes
Emergency Power Off (EPO) Port
Yes
LED Indicators
Yes
Audible Alarms
Yes
SNMP / HTTP Remote Monitoring
1 2 3 4 5 6 7 8
Yes, with optional RMCARD302 / RMCARD303
Physical Form Factor
Tower
Physical Size Physical - UPS Module Dimensions (WxHxD) (mm.)
260 x 708 x 550
Weight (kg.)
70
25
86
28
Environmental Operating Temperature
32 °F to 104 °F / 0 °C to 40 °C
Operating Humidity
0% - 90% non-condensing
Operating Elevation
0-3281 feet (0-1000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Relative Humidity Online Thermal Dissipation
0% - 95% non-condensing 1603 BTU/hr
1603 BTU/hr
12
12
4
4 13
14
2672 BTU/hr
2672 BTU/hr
Power On/Off Button Function Buttons Multifunction LCD Readout Input Circuit Breaker Battery Backup & Surge Protected Outlets Serial Port USB Port Surge Protected Communication Ports RJ45/RJ11
9 10 11 12 13 14 15 16
15
13
▲OLS2000E/OLS2000EXL
PowerPanel® Business Edition
Software
17
5
5
7 Hours
Smart Battery Management (SBM) Mode
9
8
0ms
12V/7AH
16
10
2
Runtime at Full Load (min) Battery Size
6 11
9
11
Battery
Battery Type
▲OLS3000ERT2U/ERTXL2U
7 6 3
1
Outlet Type
▲OLS2000ERT2U/ERTXL2U
11
4
1
50/60Hz ± 0.05Hz AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120% Bypass Mode: Warning only @ 130%>Load>105%, Shutdown immediately @ Load>130%
Overload Protection
8
▲OLS1000E/OLS1500E/OLS1000EXL/OLS1500EXL
208, 220, 230, 240Vac (Configurable)
On Battery Frequency
10
12 4
Sine Wave
On Battery Voltage
5
10
9
▲OLS3000E/OLS3000EXL
4
SNMP/HTTP Network Slot Extended Runtime Battery Module Connector Emergency Power Off Connector
13
AC Input Inlet Terminal Block Output Circuit Breaker Maintenance Switch Dry Contact (Optional)
▲OLS6000E/OLS6000EXL
▲OLS10000E/OLS10000EXL
17 Parallel Port
External Battery Packs
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners
External Battery Packs Model Name
BPSE36V45ART2U
BPSE72V45ART2U
BPSE36V45A
BPSE72V45A
BPSE240V47A
Voltage
36V
72V
36V
72V
240V
Amperage
40A
40A
40A
40A
25A(6K) / 42A(10K)
B
General
Battery Battery Type
Sealed Lead-Acid
Battery Size Battery Quantity
12V/7AH 6
12
6
User Replaceable
Yes
Hot-Swappable
Yes
Typical Recharge Time
Replacement Battery Pack Quantity
20 -
Input Connector On-board Replaceable Fuse Cover Output Connector Output Terminal Block Input Terminal Block
E
C
Depends on external charger
Expansion Ready (Daisy-chain) Replacement Battery Pack
12
A B C D E
Yes - Power plugs for Module RBP0068
RBP0071
-
1
1
-
438 x 88 x 430
438 x 88 x 610
151 x 225 x 394
196 x 337 x 416
260 x 718 x 550
24.2
34.7
17.2
34.2
105
Physical Dimensions (WxHxD) (mm.) Weight (kg.) Environmental Operating Temperature
B
32 °F to 104 °F / 0 °C to 40 °C
Operating Humidity
0% - 90% non-condensing
Operating Elevation
0-5000 feet (0-1500 meters)
Storage Temperature
-4 °F to 104 °F / -20 °C to 40 °C
Storage Relative Humidity
B C
A
A
A
B
C
C
0% - 90% non condensing
Compatible Models Compatible Models
OLS1000ERT2U; OLS1500ERT2U OLS1000ERTXL2U; OLS1500ERTXL2U
OLS2000ERT2U; OLS3000ERT2U OLS2000ERTXL2U; OLS3000ERTXL2U
OLS1000E; OLS1500E OLS1000EXL; OLS1500EXL
OLS2000E; OLS3000E OLS2000EXL; OLS3000EXL
OLS6000EXL OLS10000EXL
▲BPSE36V45ART2U/BPSE72V45ART2U
▲BPSE36V45A
▲BPSE72V45A
▲BPSE240V47A
41 ONLINE SERIES
ONLINE SERIES Smart Battery Management (SBM)
Online Output Voltage Setting
Smart Battery Management (SBM) is an intelligent management procedure that can prevent premature wear-out of the batteries. By charging the batteries in several phases with different current levels, SBM can eliminate over-charged situations. Furthermore, when combined with the temperature compensation feature, SBM dramatically reduces the deterioration of battery capacity caused by exhaust heat during a working cycle.
Online Double Conversion Topology
Online Double Conversion Topology provides an extra layer of insulation from power problems, achieved by continuously operating off battery power and having zero transfer time during power outages. It also stabilises output frequency and voltage, eliminates any line noise that may be apparent in industrial settings or when operating off generator power.
The Online Series provides real-time adjustable output voltage level setting that allows more flexibility for different application scenarios. Users can select from 200V, 208V, 220V, 230V and 240V simply by few button clicks of the control panel.
Generator Mode Setting
By selecting the generator as an input power source, the Online Series will coexist with household power generator, whilst ensuring the output power quality without sacrificing any protection.
Dual Input*
The Online Series when equipped with dual AC input (also known as “HotStandby”) ensures greater availability of the UPS. This feature delivers a secondary source of AC input as the backup supply for when the major input source is down. Together with dual UPS application, it can ensure high-quality output power even under bypass mode.
Featuring Online Double Conversion UPS topology, the Online Series UPS provides the highest level of power protection and a guaranteed quality power supply to demanding businesses that value manageability and performance. This series features numerous engineering excellences including Economy Mode Setting, Smart Battery Management and Generator Mode Setting, all to further enhancing its capability. With its zero transfer time, the Online Series ensures continuous, consistent and clean Pure Sine Wave power to all mission-critical equipment.
42
Detachable PDU*
For seamless and efficient maintenance or replacement, selected models are available with detachable PDU to allow the engineer to configure, repair or replace the UPS unit more easily without shutting down connected servers.
Technical Specifications
Smart Fan Speed Control by Load Level
Model Name
Economy Mode Setting
The system will automatically adjust the fan speed by monitoring the current operating status including the load level, operating temperature and other factors to enable safe, stable and more energy-saving operation.
OL6000ERT3UD
OL6000ERT3UDM
OL8000ERT3UD
OL8000ERT3UDM
OL10000ERT3UD
The Economy Mode Setting increases the operating efficiency of UPS, by up to 95% under ECO mode, while also generating less BTU heat output and reducing operating energy costs.
UPS Topology
Double-Conversion
Energy Saving
ECO Mode Efficiency >95%
Energy Star Qualified
Yes
Active PFC Compatible
Yes
Voltage
OL1500ERTXL2U
OL2000ERTXL2U
OL3000ERTXL2U
OL1000EXL
OL1500EXL
OL2000EXL
OL3000EXL
General UPS Topology
Double-Conversion
Energy Saving
ECO Mode Efficiency >93%
Active PFC Compatible
Yes
Voltage
200 - 240Vac 120Vac – 139Vac for 0 – 60% Load, 140Vac – 159Vac for 0 – 70% Load, 160Vac – 179Vac for 0 – 80% Load, 180Vac – 189Vac for 0 – 90% Load, 190Vac – 300Vac for 0 – 100% Load
Input Frequency Range Rated Input Current
50/60Hz ± 10Hz (Auto-sensing) 5A
7.5A
10A
15A
5A
Input Power Factor
7.5A
10A
15A
0.99
Cold Start
120Vac – 139Vac for 0 – 25% Load, 140Vac – 159Vac for 0 – 50% Load, 160Vac – 179Vac for 0 – 75% Load, 180Vac – 280Vac for 0 – 100% Load
Input Frequency Range
50/60Hz ±10Hz (Auto-sensing)
Rated Input Current
30A
40A
Input Power Factor
0.99
Cold Start
Yes
Plug Type
Terminal Block
50A
30A
40A
50A
VA
6000
8000
10000
6000
8000
10000
Watts
5400
7200
9000
5400
7200
9000
On Battery Waveform
Sine Wave
On Battery Voltage
200, 208, 220, 230, 240Vac (Configurable) ±2%
On Battery Frequency
50/60Hz (auto-sensing or configurable) ± 0.25Hz
Overload Protection
Yes
Plug Type
OL10000E
Output
Input Input Voltage Range
OL8000E
200 - 240Vac
Input Voltage Range OL1000ERTXL2U
OL6000E
Input
Technical Specifications Model Name
OL10000ERT3UDM
General
IEC C14
IEC C20
IEC C14
IEC C20
1.8
3
1.8
3
Outlets - Total
Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec; Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec 4
1
4
1
4
1
11
(1) IEC320 C19, (2) IEC320 C13, (1) Terminal Block
Terminal Block
(1) IEC320 C19, (2) IEC320 C13, (1) Terminal Block
Terminal Block
(1) IEC320 C19, (2) IEC320 C13, (1) Terminal Block
Terminal Block
(2) IEC320 C19, (8) IEC320 C13, (1) Terminal Block
VA
1000
1500
2000
3000
1000
1500
2000
3000
Outlets - Battery & Surge Protected
4
1
4
1
4
1
11
Watts
900
1350
1800
2700
900
1350
1800
2700
Outlets - Critical Load
2
1
2
1
2
1
6
Outlets - Non-Critical Load (NCL)
2
0
2
0
2
0
5
Cord Length (m) Output
On Battery Waveform
Sine Wave
On Battery Voltage On Battery Frequency Overload Protection
200, 208, 220, 230, 240Vac (Configurable) ± 2%
Rated Power Factor
0.9
50/60Hz (auto-sensing or configurable) ± 0.25Hz
Harmonic Distortion
THD < 3% at Linear Load, < 5% at Non-linear Load
Transfer Time
Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec; Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec
Outlets - Total
8
Outlet Type
(8) IEC320 C13
(1) IEC320 C19, (8) IEC320 C13
8
Outlets - Critical Load
4
5
Outlets - Non-Critical Load (NCL)
4
4
(9) IEC320 C13
(1) IEC320 C19, (8) IEC320 C13
9
Rated Power Factor
6
5
3
4
15.8
13.5
13.5
12.5
12.5
15.8
13.5
12.5
5.3
5.3
5.5
5.5
4.3
4.3
5.3
5.5
4.3
18
9
18
9
Runtime at Full Load (min)
6
3
6
3
Battery Type
14
9
14
9
4
3
4
3
12V/9AH
Battery Quantity
12V/7AH
3
12V/9AH
6
12V/7AH
12V/9AH
3
User Replaceable
20
BPE36V60ART2US
BPE72V60ART2US
RBP0074
RBP0076
BPE240V50ART3US
RBP0073
RBP0072
1,780 Joules
BPE36V60AS RBP0075
1,335 Joules
BPE72V60AS RBP0074
RBP0079
1,780 Joules
Phone / Network Protection RJ11/RJ45
RBP0078 1,335 Joules
1-In, 1-Out (Combo)
Management & Communications LCD Control Panel
Yes Yes (Requires a separate DB26 Cable)
HID Compliant USB Port
Yes
Serial Port
Yes
Power On (White), Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red)
Audible Alarms
Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery PowerPanel® Business Edition Yes, with optional RMCARD302 / RMCARD303
Physical
Yes
Serial Port
Yes
Form Factor
Emergency Power Off (EPO) Port
Yes
Physical Size
Rack/Tower
Power On (White), Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red)
Audible Alarms
Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery
Dimensions (WxHxD) (mm.) Weight (kg.)
PowerPanel® Business Edition
Installed Rack Height
Yes, with optional RMCARD302 / RMCARD303
Physical - Power Module
433 x 264 x 660
Rack/Tower
Tower
Physical Size
265 x 600 x 660
100
Dimensions (WxHxD) (mm.)
Physical Form Factor
Tower
Physical - UPS Module
Yes (Configurable, [I/P Power Fail] [Battery Low] [Summary Alarm] [UPS On Bypass] [UPS Fail])
LED Indicators
SNMP / HTTP Remote Monitoring
Yes (Configurable, [I/P Power Fail] [Battery Low] [Summary Alarm] [UPS On Bypass] [UPS Fail])
LED Indicators
HID Compliant USB Port
Software
Yes
Dry Contacts
SNMP / HTTP Remote Monitoring
Yes (Requires a separate DB26 Cable)
Dry Contacts
102
95
97
6U
-
433 x 132 x 660
-
Weight (kg.)
24
-
Installed Rack Height
3U
-
Physical - Battery Module
Physical - UPS Module 433 x 88 x 430
433 x 88 x 600
167 x 232 x 397
212 x 338 x 410
18
32
16
32
Weight (kg.) Installed Rack Height
2U
Dimensions (WxHxD) (mm.) Weight (kg.)
433 x 132 x 660
-
76
Installed Rack Height
-
78
-
3U
-
Environmental
Environmental Operating Temperature
Operating Temperature
32 °F to 104 °F / 0 °C to 40 °C
32 °F to 104 °F / 0 °C to 40 °C
Operating Humidity
0% - 90% non-condensing
Operating Humidity
0% - 90% non-condensing
Operating Elevation
0-10000 feet (0-3000 meters)
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Relative Humidity Online Thermal Dissipation
RBP0072
2,430 Joules
Software
Yes
Detachable LCD Control Panel Option
BPE240V30AS RBP0073
1-In, 1-Out (Combo)
Emergency Power Off (EPO) Port
Surge Suppression
5 Hours
Surge Protection & Filtering
Detachable LCD Control Panel Option
Surge Protection & Filtering
Dimensions (WxHxD) (mm.)
BPE240V30ART3US
LCD Control Panel
Yes
Replacement Battery
4 Hours
Management & Communications
5 Hours
Smart Battery Management (SBM) Mode
12V/9AH
Yes
Phone / Network Protection RJ11/RJ45
Yes
Typical Recharge Time
5 Hours
Smart Battery Management (SBM) Mode Extended Battery Module
12V/7AH
Yes 4 Hours
Surge Suppression
6
Yes
Hot-Swappable
12V/9AH Yes
Replacement Battery
Sealed Lead-Acid
Battery Size
12V/7AH
Battery Quantity User Replaceable Typical Recharge Time
Runtime at Half Load (min)
Sealed Lead-Acid
Hot-Swappable
0ms
Battery
Extended Battery Module
15.8
Runtime at Full Load (min) Battery Size
THD < 3% at Linear Load, < 5% at Non-linear Load
Transfer Time
Runtime at Half Load (min) Battery Type
0.9
Harmonic Distortion
0ms
Battery
9
Outlets - Battery & Surge Protected
Outlet Type
Storage Relative Humidity
0% - 95% non-condensing 341 BTU/hr
512 BTU/hr
759 BTU/hr
1139 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners
341 BTU/hr
512 BTU/hr
759 BTU/hr
1139 BTU/hr
Online Thermal Dissipation
0% - 95% non-condensing 1823 BTU/hr
2430 BTU/hr
#All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners.
3038 BTU/hr
1823 BTU/hr
2430 BTU/hr
3038 BTU/hr
43 ONLINE SERIES
ONLINE SERIES
▼OL1/1.5/2/3K Model
Rackmount Model 1
2
Tower Model
3
8 10
9 14 5
▼OL1/1.5/2/3K Model
1 2
6
8
11
2
10 7
9
11 14 5
4
12 11
7 13
6
12
3 1
▲ OL1000ERTXL2U/OL1500ERTXL2U
7 13
9
4
13 8
10 8
▲ OL2000ERTXL2U
14
1
2
10
9
9
3 4
UPS Status/Fault/Replace Battery
3 4 5 6 7 8
13 14 15 16 17 18 19 20 21
Multifunction LCD Readout Function Buttons Input Circuit Breaker Input/Output Terminal Block Output Circuit Breaker Battery Backup & Surge Protected Outlets
9 10
Serial Port USB Port
5 6
7
8
9 10 11
Surge Protected Communication Ports-
Tower Model
5 6
Multifunction LCD Readout Function Buttons Input Circuit Breaker Battery Backup & Surge
12 5 14
14
Serial Port USB Port Surge Protected Communication Ports- RJ11/RJ45
10 11 12
12
▲ OL2000EXL
Relay Output Connector SNMP/HTTP Network Slot Extended Runtime Battery Pack Connector
13
▲ OL3000EXL
EPO (Emergency Power Off) Connector
14
AC Input Inlet
11 12
Remote Control Port
Relay Output Connector SNMP/HTTP Network Slot
1
Extended Runtime Battery Pack Connector
2
3 4
17 13
EPO (Emergency Power Off) Connector Backfeed Protection Connector
16
Maintenance Bypass Switch
14
1 2
11 10 9
3 4 5* 6 7 8
DC Input Connector On-board Replaceable Fuse Cover
18
9 10
7
16
16
17
17
15
15
UPS Status/Fault/Replace Battery
8 12
Surge Protected Communication Ports- RJ11/RJ45
13 14 15
Multifunction LCD Readout Function Buttons Input Circuit Breaker Input/Output Terminal Block
Relay Output Connector SNMP/HTTP Network Slot Extended Runtime Battery Pack Connector
16
Output Circuit Breaker Battery Backup & Surge Protected
EPO (Emergency Power Off) Connector
17 18
Outlets
5*
12 13 14
Power Button/Power On Indicator LED Indicator
DC Output Cable
9 10 11
18
11
3 4 5 6
▼OL6/8/10K Model
* Input Circuit Breaker for 6000VA units in 3UD/3UDM model.
12 13 14
UPS Status/Fault/Replace Battery LED Indicator
13
Protected Outlets
15 5
▲ External Battery Packs for RM Model: BPE240V30ART3US/BPE240V50ART3US
5
Power Button/Power On Indicator
Remote Control Port RJ11/RJ45
LED Indicator
7
7 8 9
6
OL1500EXL
11 12
8
10
▲ OL1000EXL/
▼OL6/8/10K Model
Power Button/Power On Indicator
13 11
6
▲ OL3000ERTXL2U
1 2
7
6
14
Rackmount Model
44
Serial Port
Backfeed Protection Connector Maintenance Bypass Switch
USB Port
5*
Input Circuit Breaker for 6000E model.
15
6
▲ 3UD Model OL6000ERT3UD/OL8000ERT3UD/ OL10000ERT3UD
▲ 3UDM Model OL6000ERT3UDM/OL8000ERT3UDM/ OL10000ERT3UDM
20 19
21
▲ OL6000E/OL8000E/OL10000E
20 19
21
External Battery Packs External Battery Packs Model Name
BPE36V60ART2US
BPE72V60ART2US
BPE36V60AS
BPE72V60AS
36V
72V
36V
72V
BPE240V30ART3US
BPE240V50ART3US
A
BPE240V30AS
D
General Voltage Amperage
60A
A
B
F
Fuse Cover
240V 30A
50A
30A
B C
Battery Battery Type
Sealed Lead-Acid
Battery Size Battery Quantity
Sealed Lead-Acid
12V/9AH 6
12V/7AH 12
6
12V/7AH 12
12V/9AH
40
Yes
-
Yes
-
Hot-Swappable
Yes
-
Yes
-
Replacement Battery Pack Replacement Battery Pack Quantity
RBP0077
-
2
RBP0073
-
RBP0072 2
BPE72V60ART2US
C
B
B
-
C
B
F
Physical Dimensions (WxHxD) (mm.) Weight (kg.)
433 x 88 x 430
433 x 88 x 660
167 x 232 x 397
212 x 336 x 414
23
44
23.5
43.5
433 x 132 x 660 76
265 x 600 x 660 78
D
A
135
A
Environmental Operating Temperature
0% - 90% non-condensing
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
5 °F to 113°F / -15°C to 45 °C
Storage Relative Humidity
▲ BPE240V30ART3US/ BPE240V50ART3US
0% - 95% non condensing
Compatible Models Compatible Models
E
32 °F to 104 °F / 0 °C to 40 °C
Operating Humidity
OL1000ERTXL2U; OL1500ERTXL2U
OL2000ERTXL2U; OL3000ERTXL2U
OL1000EXL; OL1500EXL
OL2000EXL; OL3000EXL
OL6000ERT3UD; OL6000ERT3UDM
OL8000ERT3UD; OL8000ERT3UDM; OL10000ERT3UD; OL10000ERT3UDM
C
B
DC Input Connector
C ▲ BPE36V60ART2US/
A
Yes - Power plugs for Module RBP0074
DC Output Cable
12V/7AH
20
User Replaceable Expansion Ready (Daisy-chain)
On-board Replaceable
OL6000E; OL8000E; OL10000E
A
C
▲ BPE36V60AS
▲ BPE72V60AS
▲ BPE240V30AS
45INDUSTRY TERMS Alternating Current (AC) The flow of electric charge in a circuit that is constantly being reversed back and forth. Amp (ampere, A) The standard unit of measure for electrical current, defined as the amount of electrical flow equal to one coulomb per second. Apparent Power The product of the applied voltage and current in an AC circuit. Blackout A power failure in which line voltage drops to zero. Brownout A drop in voltage in electrical power supply. Buck/Boost Full automatic voltage regulation in a UPS that stabilises low voltage (boost) and high voltage (buck) to maintain nominal 230V power, without resorting to battery power when minor power fluctuations occur. Coaxial Cable Cables that are made of an inner conductor surrounded by an insulator and a shield that are generally used for TV antennas, satellite dishes, cable modems and certain computer networking applications.
INDUSTRY TERMS
Half-Load The midpoint in the maximum load capacity for a UPS. Hard-wired High amperage devices that require installation by a qualified electrician to be directly wired-in, instead of simply being plugged in to an outlet. Hertz (Hz) The unit for frequency, defined as the number of cycles per second. Hot-Swappable Battery A term used to describe the functions of replacing a UPS battery without shutting down the unit. Joule A measure of electrical energy — one joule is defined as the energy needed to pass one ampere of current through one ohm of resistance. Line-Interactive UPS Functions the same as a standby UPS, with the additional feature of some voltage regulation built in. It switches to battery power when voltage drops too low, just as a standby UPS does, however if the voltage only drops slightly, a line-interactive UPS corrects this without using battery power. The functionality of these mid- to high-grade units falls between standby and online UPS units.
Current The flow of electric charge, measured in amps.
Load The amount of power consumed by an electrical device on a circuit. Load capacity is a critical factor in selecting a UPS or surge protector.
DHCP Dynamic Host Configuration Protocol (DHCP), automatically assigns an IP address to a device on a network.
MOV Metal Oxide Varistor is an electronic component that is used to protect circuits against excessive, short-lived, voltages.
Direct Current (DC) The unidirectional flow of a electric charge.
Nominal Voltage The standard voltage for a circuit or system. Common nominal voltages in the U.S. include 120VAC, 208VAC and 240VAC; while nominal voltage in the EU is 230VAC.
Double-Conversion UPS This high-end UPS system converts incoming utility AC power into DC power and then back into AC power, charging connected devices with the UPS battery. The isolated process ensures clean and stable output voltage and zero transfer time. This UPS system is ideal for equipment sensitive to power fluctuations such as corporate data centres, servers, and network and storage devices. Efficiency (Energy Conversion Efficiency) The ratio between the amount of apparent power and the amount of true power used by an electrical device. The closer the true power value is to the apparent power, the more efficient the device. Electromagnetic Interference (EMI) Commonly referred to as line noise, these interference signals can disrupt or degrade the performance of a circuit by inserting abnormalities into the system. Also referred to as radio frequency interference (RFI) when in high or radio frequency. Frequency The number of cycles in a given time period, which is measured in Hertz. Ground An electrical system connection that serves as a conduit between the circuit and earth.
Overvoltage This occurs when incoming voltage is higher than normal, but not high enough to be classified as a surge. Power Factor (PF) The ratio of real power (watts) to apparent power (VA), expressed as a number between 0 and 1. Watts divided by VA = Power Factor Power Factor Correction Controls the incoming power to a power supply in order to bring the power factor as close to unity power as possible. Radio Frequency Interference (RFI) See Electromagnetic Interference. Real Power The amount of power being drawn by a system, measured in watts. Real power is a function of VA (apparent power) and the power factor. RJ11, RJ14, RJ45 The abbreviation of registered jack (RJ) – RJ11 is for standard phone lines, RJ14 is for multiple phone lines and RJ45 is for Ethernet.
Runtime The maximum period of time battery power is output from a UPS to its connected devices during a power interruption. Runtime is dependent upon the total load of all connected equipment. Simulated Sine Wave A modified or approximated sine wave AC power output. Simulated (or nonsinusoidal) waveforms may also be referred to as a squared sine wave, modified sine wave, trapezoidal sine wave or quasi sine wave.
USB (HID Compliant) Universal Serial Bus devices are used to connect various components to a computer. An HID (Human Interface Device) compliant USB follows a specific protocol for communication that allows it to be used with virtually any system. Volt (V) The difference in electric potential between two points when one amp of current dissipates one watt of power.
Sine Wave A smooth, repetitive oscillation of AC power.
Volt-Ampere (VA) The unit used to express apparent power.
Single Phase Power Refers to the distribution of alternating current electric power using a system in which all the voltages of the supply vary in unison.
Voltage Regulator A device or component that normalizes voltage to a certain standard when it is fluctuating.
SMTP Simple Mail Transfer Protocol is the standard for e-mail transmission on the Internet.
Watt (W) A unit of measure for true power consumption.
SNMP Simple Network Management Protocol is a commonly used protocol for devices to communicate over a network. Spike A spike is a sudden, brief power surge, usually lasting less than 1ms. Standby UPS A UPS that passes utility power straight through to the output when conditions are stable, but switches to battery power when utility voltage drops below an acceptable level. Surge Periods when line voltage increases dramatically, typically lasting longer than 1ms, but less than a few seconds, though they can last longer. Total Harmonic Distortion (THD) A calculated measure of the reduction in sine wave clarity caused by stray wave frequencies. Thermal Dissipation The process of dissipating heat from an electrical system via air or liquid cooling; also a term for the amount of heat a device can emit. Transfer Time The time it takes UPS to switch from AC power to battery power. Transformer A device that converts AC line voltage to a higher or lower value. U The standard unit of measure for rack-mounted equipment. A device measuring 1U is 1.75 inches (44.45mm) high, 2U is 3.50 inches (88.9mm), etc. Undervoltage Related to both brownout and voltage sag, undervoltage falls between these two, occurring when voltage is lower than normal for an extended period of time without recovering, but not too low that the electronic device will not function.
Waveform Is a representation (or form) of how alternating current (AC) varies with time. Common waveform representations include sine wave, square wave and trapezoidal wave. An instrument called an oscilloscope can be used to visually represent a wave as a repeating image on a screen. Wiring-Fault Refers to an abnormal flow of current that is due to an improperly grounded electrical outlet.
CyberPower Systems Inc.