Preview only show first 10 pages with watermark. For full document please download

каталог однофазные ибп Cyberpower

   EMBED


Share

Transcript

CPSWW.COM UPS SYSTEMS PORTFOLIO UC0014EU-00 The CyberPower Story Our Core Values Founded in 1997, CyberPower has followed a path to success through engineering excellence and quality standards in power protection and computer accessories. At our advanced technology manufacturing facilities, we build a comprehensive line of power protection products, including Uninterruptible Power Supplies (UPS), Power Distribution Units (PDUs), Power Inverters, Surge Protectors, Mobile Chargers, power management software, and computer peripheral accessories. With a global presence we provide award-winning products that offer reliable power protection and a sense of security. In-house Laboratory for Certified Testing CyberPower continuously invests in its in-house laboratory and testing capabilities to deliver the highest standard of product verification and testing. Through our certified capabilities we are able to perform safety tests in-house, offer certificates of EMI, Energy Star and related pre-testing. Audited by 3rd party certificate labs including UL, TUV, SGS, Intertek and CSA, this facility ensures a timely development process as well as compliance with worldwide legal standards. No matter whether you are an IT professional working in a corporate data centre, an owner of a small-tomedium business, or a consumer using electronic devices at home, CyberPower has a wide range of power solutions to safeguard your critical equipment and valued data. Comprehensive Power Solutions As a professional power solution provider, CyberPower designs and manufactures a comprehensive range of innovative power products, including Mobile Inverters, Surge Protectors, PDU & Power Management, Mobile Chargers and PV Inverters. Our exceptional R&D capabilities enable us to produce a full range of power products, all highly engineered, resulting in top quality UPS solutions. Global Distributions CyberPower products are available through authorised distributors and sold by valuedadded resellers, system integrators, wellknown e-tailers and selected retail channels worldwide. We have a global presence via offices and distribution centers located in Americas (Canada, Mexico and the United States), Europe (France, German, Russia and the Netherlands), Asia (Japan, Taiwan, China, Thailand, Philippines, Indonesia, Myanmar, etc.), Oceania(Australia, New Zealand and Fiji), and Africa (Algeria, Cameroun, Chad and Republic Democratic of Congo) and beyond. USA Office Minneapolis, USA German Office München, Germany Mexico Office Mexico City In response to the growing demand for Green IT products, CyberPower has developed patented GreenPower UPSTM Energy-Saving Technology to improve UPS operating efficiency and greatly reduce energy consumptions. As a result, our customers can enjoy significant energy cost savings over conventional UPS systems. Japan Office Tokyo, Japan France Office Cloyes, France India Office Mumbai / Bengaluri / Kolkata / New Delhi, India 4 Manufacturing Factories Shenzhen / Hunan, China China Office Shenzhen, China The markets and worlds in which we live are changing in the blink of an eye, reacting rapidly to these changes has become a top priority for businesses today. Thanks to our efficient supply chain management strategy and systematic integration capability, we are able to meet this requirement for fast response to demanding markets. GreenPower UPSTM Technology Russia Office Moscow, Russia The Netherlands Office Eindhoven, the Netherlands Fast Response Ability Taipei Office & R&D Center Taipei, Taiwan Our Green Fact Power Consumption: GreenPower UPS™ Technology vs. Other UPS Brands Power Consumption Reduce Energy Cost Using Energy-saving Technology 60 Test 1 Unit Off No AC Load No DC Load 50 The GreenPower UPS™ Technology features multiple advanced energy-saving designs that improve operating efficiency and eliminate waste energy consumptions. Featuring Test 2 Unit On (AVR Off) No AC Load No DC Load 40 advanced high-frequency design and patented bypass circuit design, users can enjoy significant energy savings with the adoption of GreenPower UPS™ 30 Technology. Test 3 Unit On (AVR Off) Full AC Load No DC Load (Battery Full Charged) 20 10 *Test result may vary in different test environments. 0 Smart App Professional Rackmount Series Power Efficiency Other UPS Brand 1 Other UPS Brand 2 Our product can outperform other brands under any conditions 100% 90% 80% Under 25% load: 9% higher than other brands 70% Under 50% load: 7% higher than other brands Under 100% load: 3.6% higher than other brands Double Conversion On-Line UPS • High Frequency Inverter: Increased conversion efficiency and reduced energy loss when the inverter is converting DC to AC power during Battery Mode. Heat Energy Loss Heat Energy Loss Continuous Devotions to Green Management Power Flow Charge bAT. Outgoing AC Power Incoming AC Power Heat Energy Loss GreenPower UPS™ Technology increases the efficiency of your UPS by saving energy during normal utility power operation. Energy & Heat Losts The commitment to innovation, excellence, and efficiency extends throughout our company, CyberPower has adopted Green practices and certifications throughout the business, including: Membership in the Climate Savers Computing Initiative, the adoption of Restriction on Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment (WEEE) protocol, certification in ISO 14001 Environmental Management Systems and IECQ QC 080000 HSPM Hazardous Substance Process Management Standards, qualifications of ENERGY STAR®, patented energy-saving GreenPower UPS™ Technology, and other ongoing “Greening” of all packaging practices and materials to ensure the maximum consideration for the environment. CyberPower GreenPower UPSTM ISO14001 Outgoing AC Power noise Filter Charge bAT. IECQ QC080000 Load 95% 100% 90% 84% 82% 74% 69% 67% 64% 59% 56% 48% 46% 40% 35% 33% 30% 27% 24% 23% 22% *Comparison between CyberPower Smart App Professional Rackmount Series and other UPS brands. Line Interactive UPS noise Filter Incoming AC Power 18% 1. UPSs working in in-line mode with resistive load. 2. Batteries are fully charged. bAT. No Bypass Circuit Design While conventional UPS systems pass power through a transformer to provide normal output voltage to protect devices, the patented GreenPower UPS™ circuitry bypasses the transformer during normal utility power operation, which significantly increases the power efficiency of the UPS. As utility power is normal in over 88% of the time, GreenPower UPS™ Technology operates primarily in its cost-reducing bypass mode, thus lowering energy costs by up to 75% compared to conventional UPS models. Power Conversion 16% Unstable utility supply Power Conversion 12% Suiting Stable Utility supply noise Filter 8% Operating environment 0% Charge 11% Varies depending on model 10% 7% No Energy saving Brand A-UPS1500 Brand B-UPS1500 6% AVR Physical Efficiency Stability CyberPower-PR1500ELCDRT2U 20% 5% Conventional UPS Larger in size / Heavier Less efficiency Better stability 30% 3% High Frequency UPS Smaller in size / Lighter Better efficiency Advanced circuit design for good stability Yes, less energy loss during charging and/ or conversion 40% 2% • High Efficiency Charger: Increased charging efficiency and reduced energy loss during the battery charging process in AC Mode. 50% 1% High-Frequency Design The high-frequency design includes a compact energy-efficient inverter and charger with the following features: Traditional online double-conversion and line-interactive UPS designs can have efficiencies as low as 85% under full load. The energy lost by these UPS designs during normal utility power operation is significant. 0% The GreenPower UPS™ Design Efficiency 60% Choosing the Right UPS for Your Equipment An uninterruptible Power Supply (UPS) provides battery backup power and extra runtime to connected devices when the input power source, usually utility power, fails or drops to an unexpected voltage level. For small UPS systems, the on-battery runtime is relatively short, usually just a few minutes, yet sufficient for operators to save files and power down computers in an orderly manner. For large UPS systems, most industry-level UPSs accept optional external battery packs for additional runtime, often up to several hours. At CyberPower, we offer users, from Home Office to IT Professionals, a wide selection of UPS solutions. All designed to protect sensitive equipment and valued data from harm caused by power problems. To better assist you in choosing the right power solution for your equipment, typology and output wave form requirement, we have produced this summary to help you understand the different options: Topologies Essential Protection ▬ Offline/Standby The Standby UPS, also known as Offline UPS to be distinguished from Online UPS, is the simplest and least expensive UPS type. Primary power source is utility power and battery is the second. Normally, the battery remains charged by utility power and the inverter only starts when AC power fails, hence being known as “Standby”. Seamless Connection & Ultimate Protection ▬ Online (Double Conversion Topology) In the Online (Double Conversion) UPS, failure of input AC will not cause the activation of the transfer switch, as the primary power source is NOT the utility power, but the backup source instead. During normal operation, the UPS is running off the battery and using its inverter for loads while the battery charger is running from line power, hence the name of Online (Double Conversion) UPS. In the event of power failure, only the battery charger would fail and the inverter will keep providing loads as normal from the battery. As no transfer time is needed when the power goes out, equipment powered by an Online UPS can remain operating without interruption, so that makes it perfect for valued devices that have zero tolerance of power outages! Also, with the equipment running off the battery most of the time, any noisy power or unpleasant surprises from the wall socket can be isolated from the output loads and affect only the battery charger. Therefore, the Online UPS can ensure continuous, consistent and clean pure sine wave power to mission-critical equipment, regardless of the incoming power. Features Below is a list of innovative features that can be found on CyberPower UPS products. Some features may only be available on selected products. For detailed features and specifications of each UPS model, please refer to our website at www.cpsww.com. • Automatic Voltage Regulation (AVR) • Critical Load Outlets • Emergency Power Off Port (EPO) • GreenPower UPS™ Technology • Multifunction LCD Display Panel • Convertible Rack/Tower Configuration • Data and Phone Line Protection • Extended Runtime • Hot-Swappable, Front-Load Batteries • PowerPanel® Management Software Applications The common applications of UPS systems are: PCs / WORKSTATIONS Monitors, PCs or external peripherals AUDIO / VIDEO SYSTEMS Stereos, TV, DVD players, Games consoles NETWORK DEVICES Hubs, routers, switches, and Wireless AP OFFICE DEVICES Fax machines, scanners, and projectors EMERGENCY SYSTEMS Emergency lightings, alarm systems, safety systems DATA STORAGE ARRAYS RAID systems and tape drivers TELECOM DEVICES Home systems, monitoring systems and POS DVRs / SURVEILLANCE SYSTEMS Safety and surveillance systems SERVERS Firewalls, data centers or server rooms INDUSTRIAL EQUIPMENT Central control systems, factories BYPASS IN AC/DC PFC SWITCH BATTERY CHARGER AC OUT AC DC DC AC AC INVERTER DC DC INVERTER DC BUS BATTERY CHARGER AC DC IN DC/DC SWITCH OUT DC CONVERTER BATTERY BATTERY Professional & Advanced Protection ▬ Line-Interactive The Line-Interactive UPS is the most common design used for SMEs, Corporate Servers and Industrial Equipment. In this design, the AC power is still the primary power source while the battery power is secondary. However, the biggest difference from Standby UPS is that the inverter/converter unit stays permanently connected to the output for powering equipment compared. When the power fails, this design demonstrates a faster response time compared to Standby UPS, while providing additional filtering of switching transients and spikes. Automatic Voltage Regulation is another important feature that comes with most Line-Interactive UPS as it regulates high and low voltages and bring the power to a consistent nominal level. This allows the UPS to maintain safe power levels without resorting to to battery power, which significantly reduces the premature battery failure caused by frequent battery usage. It also reduces the chances of data loss, memory freezes, and system crashes. IN Output Waveform Simulated/Stepped Sine Wave The Simulated Sine Wave can be seen as a satisfactory compromise between cost and power quality. While not as pure sine wave AC power, this wave form is acceptable for most consumer electronics products. Simulated Sine Wave system produces decent battery power at a reasonable cost, hence making it widely adopted in entry- to midlevel UPS products. AVR SWITCH BATTERY CHARGER AC AC DC DC INVERTER BATTERY OUT Pure Sine Wave As the highest level of line clarity, Pure Sine Wave is the most ideal waveform for mission-critical equipment. While Simulated Sine Wave output produces a sine wave that is “stepped” or modified, Pure Sine Wave output produces a true sine wave that is similar to normal AC wall power that ensures continuous optimal operation. UPSs with Pure Sine Wave are designed for electronics utlising Active PFC power supplies or other devices that require pure sine wave . The Second-to-None in UPS Technology PowerPanel® Management Software PowerPanel® Management Software is an integral component of battery backup and data protection solutions, packaged with most CyberPower UPS products. The intuitive dashboard interface is extremely easy to navigate for first-time users and powerful enough for administrators and system integrators. In the event of power loss, PowerPanel automatically saves files and safely shuts down the computer in an orderly manner. PowerPanel® for mac & Mac energy saver ® PowerPanel Personal edition PowerPanel® for Mac is now available to provide Mac users with statistics and status information of connected CyberPower UPS via USB connection. During a power event, users can safely shut down their Mac via either the PowerPanel software or Mac Energy Saver. PowerPanel for Mac is compatible with Mac OS X 10.4.1+. * For more information, please visit www.CPSww.com under “Software”. PowerPanel® Personal edition PowerPanel® Personal Edition is designed for small office use and features a heads-up graphical interface. The friendly dashboard-style interfaces of PowerPanel® Personal Edition software make it easy to control and monitor the UPS system with a USB or serial port. In the event of power loss, the software automatically saves files, shuts down computer, and enters OS hibernation in a safe, intelligent and orderly manner. It combines graphical and statistical data in a compact, easy-to-install package is fully compatible with Mac, Linux, Windows 8, 7, Vista, XP, Window Server 2012, 2008 and 2003. Software Features • User-friendly Dashboard Interface • Load/Current Draw and Runtime Status • System Tray Notifications • Automatic File-saving, Equipment Shutdown, and OS Hibernation • Scheduled-shutdown and Restart PowerPanel® for mac & Mac energy saver POWERPANEL® for LINUX PowerPanel® for Linux allows control and monitoring of UPS attached to a Linux based computer to manage the protection of computer systems, components, peripherals, as well as the data. In the event of power loss, PowerPanel will safely shut down computers in a safe and orderly manner. POWERPANEL® for LINUX PRODUCT INDEX Home & Home Office BRICS LCD SERIES ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● USB Connectivity Port ● User-Replaceable Batteries ● Horizontal/Wall-Mounted Use ● Cable Collector Included ● External Battery Charger* ● USB Charging Port* ● PowerPanel® Personal Edition Software ● GreenPower UPS™ Technology ● EMI, RFI, Surge and Lightning Spike Protection ● Auto-Restart / Auto-Charge ● USB Connectivity Port ● User-Replaceable Batteries ● Horizontal / Wall-Mounted Use ● Cable Collector Included ● PowerPanel® Personal Edition Software 14 15 P. EX SERIES ● GreenPower UPSTM Technology ● EMI, RFI, Surge and Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LED Status Indicator ● USB Connectivity Port ● Easy Battery Replacement ● PowerPanel® Personal Edition Software HOME THEATER SYSTEM VALUE SERIES 18 VALUE SOHO SERIES ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● USB & Serial Connectivity Ports ● User-Replaceable Batteries ● PowerPanel® Personal Edition Software 13 SMALL OFFICE P. DX / DL SERIES ● GreenPower UPS™ Technology ● EMI, RFI, Surge and Lightning Spike Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor* ● USB Connectivity Port ● PowerPanel® Personal Edition Software 17 P. ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LED Status Indicators* ● LCD Status Monitor* ● USB & Serial Connectivity Ports ● PowerPanel® Personal Edition Software P. 16 P. BS SERIES P. PRODUCT INDEX Backup UPS Systems The Backup UPS Systems offers home and small office users peaceof-mind of surge protection and battery backup for protection against brownouts, AC power sags and total power outages. MEDIUM BUSINESS 19 P. 20 P. PFC SINEWAVE SERIES ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● User-friendly Control Switch USB Charging Ports* ● User-Replaceable Batteries ● PowerPanel® Personal Edition Software INTELLIGENT LCD SERIES ● GreenPower UPS™ Technology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● LCD Status Monitor ● USB Connectivity Port ● User-Replaceable Batteries ● PowerPanel® Personal Edition Software *= Select Models FEATURE INDEX FEATURE INDEX Cable Collector A well-suited solution to better assist in maintaining a neat and tidy work space. It simplifies the cable arrangement therefore increases the structural reliability for the total set of distribution cables. RJ11/RJ45 PROTECTION CABLE COLLECTOR RJ11/RJ45 Protection AUTOMATIC VOLTAGE REGULATION (AVR) The RJ11/RJ45 port is designed to protect data lines and communication equipment from AC transients caused by surge, electrostatic discharge and other power abnormalities. AVR INCONSISTENT UTILITY POWER CONSISTENT SAFE POWER Automatic Voltage Regulation (AVR) Convenient Mounting A space-wise design that allows multiple mounting options including horizontal, cabinet and wall-mounted orientation to make the most of your workspace. MULTIFUNCTION LCD READOUT CONVENIENT MOUNTING Detailed display. Clear and consistent LCD readout of power/battery status including load, runtime, power, AVR and other information at a single push-of-abutton. Also, advanced settings can be configured to the potential power problems in advance. Multifunction LCD Readout Compact display. Comparison Table Model DX/DL Series EX Series BS Series BRICs LCD Series Value Series Value SOHO Series Intelligent LCD Series PFC Sinewave Series *= Select Models Form Factor Tower Tower Brick Brick Tower Tower Tower Tower Waveform ** ** ** ** ** ** ** Pure Sine Wave ** =Featured with Simulated Sine Wave LCD * v * v v v COMPARISON TABLE AVR v v v v v VA 450-850 650-850 450-850 650-1000 600-2200 600-2200 1050-1500 900-1500 Watt 270-490 360-490 270-490 390-600 360-1320 360-1320 630-900 540-900 Outlets 3 3 6 6 3/6 2/4 6 6 RJ11/45 v v v v v v USB v v v v v v v v Software v v v v v v v v Designed for Home / SOHO Home / SOHO Home / SOHO Home / SOHO Home / SOHO / SMEs* Home / SOHO / SMEs* Home / SOHO / SMEs Home / SOHO / SMEs Clear and consistent LCD readout of power/battery status including load, runtime, power and other information at a single push-of-a-button. Also, advanced settings can be configured to the potential power problems in advance. LCD DISPLAY INFORMATION TABLE Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level for the connected equipment. AVR regulates high and low voltages and brings the power to a nominal 220/240 volts. This allows the UPS to maintain safe power levels without resorting to battery power, which significantly increases battery life and eliminates AC-DC power transfer when minor power fluctuations occur. It also reduces the chances of data loss, memory freezes and system crashes. LCD Display Information Table Load/Current Level AVR in Use* Overload Silent Mode Battery Pack Numbers* Temperature (F and C)* Runtime Battery in Use Battery Level Battery Shutdown Voltage Static Frequency Tolerance Output Frequency* Input Voltage Output Voltage Normal Operation Slew Rate * = Select Models 13 DX / DL SERIES EX SERIES 14 RJ11/RJ45 Data Line Protection The RJ11/RJ45 Data Line Protection serves to protect phone, data lines and communication equipment against AC transients caused by surge, electrostatic discharge and other power abnormalities. Designed for home and office users, the DX/DL Series UPS provides the most cost-effective battery backup for PCs and SOHO networks. With EMI/RFI filters eliminating line noise or disturbances, it can supply reliable backup during power interruptions, brownouts and blackouts. The DL Series also features a multifunction LCD readout for immediate access to precise information about critical power/battery condition. With its cutting-edge compact design, it can make the most of your workspace. Featuring a surge protected RJ11/RJ45 port, the EX Series UPS is ideal for home entertainment systems and SOHO networks, offering full protection against surge/spikes and power abnormalities. With EMI/RFI filters eliminating line noise or disturbances, it can supply reliable backup during power interruptions, brownouts and blackouts. Its Space-wise tower design means it can be placed horizontally or vertically to make the most your workspace! 1. Power On/Off Switch 2. LED Status Indicator 3. Battery Capacity Indicator 4. LCD Display 5. LCD Function Select Switch* 6. AC Outlets* 7. Communication Port to PC (USB) 8. Circuit Breaker Protection 3 4 2 1 1 5 2 7 3 6 1. Power On/Off Switch 2. AC Outlets* 3. Communication Protection Ports RJ11/RJ45 UK socket* FR socket* 5 8 UK socket* FR socket* *= Other socket types available upon request 4 4. Communication Port to PC (USB) 5. Circuit Breaker Protection AS socket* *= Other socket types available upon request AS socket* Technical Specifications Model Name EX650E EX850E General Technical Specifications Model Name DX450E DX650E DX850E DL450ELCD DL650ELCD DL850ELCD General UPS Topology Standby Energy Saving Yes Input Voltage UPS Topology Standby Energy Saving Yes 192Vac - 263Vac Input Frequency Range Input 50/60Hz ± 3Hz (Auto-sensing) Rated Input Current Voltage 230Vac Input Voltage Range 5A Plug Type Schuko or UK or NEMA VA 650 850 Watts 360 490 On Battery Waveform Output 230Vac ± 10% 50/60Hz ± 1% 450 650 850 450 650 850 On Battery Frequency Watts 270 360 490 270 360 490 Outlets - Total Simulated Sine Wave 230Vac ± 7% Outlets - Battery & Surge Protected On Battery Frequency 50/60Hz ± 1% Transfer Time 3 Outlet Type 3 Outlet Type On Battery Voltage Outlets - Total Simulated Sine Wave On Battery Voltage VA On Battery Waveform Schuko or UK Output 50/60Hz ± 3Hz (Auto-sensing) Rated Input Current 10A Plug Type 192Vac - 263Vac Input Frequency Range Schuko or FR or UK (UK x 2 + IEC x 1) 2 4ms Battery Schuko or FR or UK (UK x 2 + IEC x 1) or AS Runtime at Half Load (min) 6 3 Runtime at Full Load (min) 1 Outlets - Battery & Surge Protected Transfer Time 4ms 7 2 Battery Type Battery Sealed Lead Acid Battery Quantity Runtime at Half Load (min) 6 6 7 Runtime at Full Load (min) 2 1 2 Battery Type 6 6 7 User Replaceable 2 1 2 Typical Recharge Time Sealed Lead Acid Battery Quantity Replacement Battery Pack 1 Typical Recharge Time 1 Yes 8 Hours RBP0080 RBP0081 Replacement Battery Pack Quantity 8 Hours 1 Surge Protection & Filtering Surge Protection & Filtering Surge Suppression Surge Suppression 405 Joules 1215 Joules Phone / Network Protection RJ11/RJ45 Management & Communications 1-In, 1-Out (Combo) Management & Communications HID Compliant USB Port Yes LED Indicators HID Compliant USB Port Using AC, Using Battery, Fault, Battery Capacity Audible Alarms On Battery, Low Battery, Overload,Fault PowerPanel® Personal Edition Software Yes LED Indicators Power On, Wiring Fault Audible Alarms On Battery, Low Battery, Overload PowerPanel® Personal Edition Software Physical Physical Form Factor Tower Form Factor Physical Size Brick Physical Size Physical - UPS Module Physical - UPS Module Dimensions (WxHxD) (mm.) Weight (kg.) 230Vac Input Voltage Range 90 x 190 x 235 2.1 2.8 Dimensions (WxHxD) (mm.) 3.0 2.1 2.8 3.0 Environmental Weight (kg.) 100 x 84 x 309 2.7 3 Environmental Operating Temperature + 32°F to 104° F / 0° C to 40° C Operating Temperature + 32°F to 104° F / 0° C to 40° C Operating Humidity 10% - 95% non-condensing Operating Humidity Operating Elevation 0-1000 meters Operating Elevation 0-1000 meters Storage Temperature +5 °F to 113°F / -15°C to 45 °C Storage Temperature - 4°F to 122° F / -20° C to 50° C Storage Relative Humidity Online Thermal Dissipation 10% - 95% 21 BTU/hr 30 BTU/hr 41 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 0% - 90% non-condensing Storage Relative Humidity 21 BTU/hr 30 BTU/hr 41 BTU/hr Online Thermal Dissipation 0% - 90% 30 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners 41 BTU/hr 15 BS SERIES BRICS LCD SERIES EMI/RFI Noise Filtering External Battery Charger** The advanced EMI/RFI Noise Filtering helps to reduce electromagnetic and radio frequency interference problems. These filters smooth out minor current fluctuations and therefore improves picture and sound quality in audio/video systems. The external battery charger is an add-on component, which allows you to charge an additional 4 AA/AAA batteries while utlising the UPS. *Note: AA/AAA batteries are NOT included. The BS Series UPS provides home and office users peace of mind surge protection against spikes and power abnormalities. With EMI/RFI filters eliminating line noise or disturbances, it can supply reliable backup during power interruptions, brownouts and blackouts. The flexible mounting design allows placement options including horizontal, cabinet, and wall-mounted orientation. The BRICs LCD Series UPS offers home and small office users clean and stable battery backup, with the RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. With Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. Flexible mounting design allows placement options including horizontal, cabinet, and wall-mounted orientation. 3 FR socket* 5 1 UK socket* 6 9 1. Power On/Off Switch 2. Power On Indicator 3. AC Outlets* 4. Communication Port to PC (USB) 5. Circuit Breaker Protection 6. Cable Collector 6 FR socket* 4 5 3 1. Power On/Off Switch 2. LCD Function Select Switch 3. LCD Display 4. Communication Protection Ports RJ11/RJ45 5. Battery Charger USB Port 6. AC Outlets* 7. Communication Port to PC (USB) 8. Circuit Breaker Protection 9. Cable Collector * =Other socket types available upon request 8 1 7 UK socket* 4 2 * =Other socket types available upon request 2 6 3 Technical Specifications Model Name BS450E BS650E BS850E General Standby Energy Saving Yes UPS Topology Line-interactive Energy Saving Yes Voltage 165Vac - 280Vac Input Frequency Range Voltage 230Vac Input Voltage Range Schuko or UK Output 10A Plug Type 10A Plug Type 50/60Hz ± 3Hz (Auto-sensing) Rated Input Current 50/60Hz ± 3Hz (Auto-sensing) Rated Input Current 192Vac - 263Vac Input Frequency Range Schuko or UK Output VA 650 850 1000 Watts 390 510 600 On Battery Waveform VA 450 Watts 270 On Battery Waveform 650 850 On Battery Voltage 360 490 Automatic Voltage Regulation (AVR) Simulated Sine Wave 230Vac ± 7% Outlets - Total On Battery Frequency 50/60Hz ± 1% Outlet Type Outlets - Total 6 Outlet Type 3 Transfer Time 4ms 6 Runtime at Full Load (min) 2 Battery Type 4ms 9 8 7 2 2 0.5 1 2 Battery Type RBP0080 Replacement Battery Pack Quantity Transfer Time Runtime at Full Load (min) Sealed Lead Acid Battery Quantity 1 User Replaceable Yes Typical Recharge Time 8 Hours RBP0082 Yes Runtime at Half Load (min) Yes Typical Recharge Time 3 USB Charging Ports 7 1 User Replaceable 3 7 Sealed Lead Acid Battery Quantity 6 Schuko or FR or UK (UK x 4 + IEC x 2) Battery Battery Runtime at Half Load (min) Yes 50/60Hz ± 1% Outlets - Surge-Only Protected 3 Outlets - Surge-Only Protected 230Vac ± 10% Outlets - Battery & Surge Protected Schuko or FR or UK (UK x 4 + IEC x 2) Outlets - Battery & Surge Protected Simulated Sine Wave On Battery Frequency On Battery Voltage Replacement Battery Pack RBP0081 1 8 Hours RBP0083 RBP0006 Replacement Battery Pack Quantity 1 Surge Protection & Filtering Surge Protection & Filtering Surge Suppression Surge Suppression 405 Joules (L-N) 125 Joules (L-N) Phone / Network Protection RJ11/RJ45 Management & Communications '1-In, 1-Out (Combo) Management & Communications HID Compliant USB Port Yes LED Indicators Power On, Using Battery Audible Alarms On Battery, Low Battery, Overload, Fault LCD Control Panel Yes HID Compliant USB Port Yes Audible Alarms PowerPanel® Personal Edition Software On Battery, Low Battery, Overload, Fault ® PowerPanel Personal Edition Software Physical Physical Form Factor Brick Form Factor Physical Size Brick Physical Size Physical - UPS Module Physical - UPS Module Dimensions (WxHxD) (mm.) 160 x 114 x 271 2.6 3.1 Dimensions (WxHxD) (mm.) 3.4 Environmental Weight (kg.) 359 x 162 x 113 5.6 6.6 6.8 Environmental Operating Temperature + 32°F to 104° F / 0° C to 40° C Operating Temperature + 32°F to 104° F / 0° C to 40° C Operating Humidity 0% - 90% non-condensing Operating Humidity Operating Elevation 0-1000 meters Operating Elevation 0-1000 meters Storage Temperature - 4°F to 122° F / -20° C to 50° C Storage Temperature - 4°F to 122° F / -20° C to 50° C Storage Relative Humidity Online Thermal Dissipation BR1000ELCD 230Vac Input Voltage Range Input Weight (kg.) BR850ELCD Input UPS Topology Replacement Battery Pack BR650ELCD General Technical Specifications Model Name 0% - 90% 14 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 18 BTU/hr 16 0% - 90% non-condensing Storage Relative Humidity 21 BTU/hr Online Thermal Dissipation 0% - 90% 71 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 72 BTU/hr 102 BTU/hr 17 VALUE SERIES VALUE SOHO SERIES Local Socket IEC Socket The Value SOHO Series UPS features standard local sockets which are commonly used in household electric appliances such as lamps, standing fan, audio/video systems, LCD TV, etc., making it the best choice for home solution. The Value Series UPS features IEC female sockets which are commonly used in electric making it the devices such as computers, workstations, laptops, printers, etc., the best choice for office solution. The Value Series UPS offers home and small office users clean and stable battery backup. The inclusion of a RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The multifunction LCD readout provides immediate access to precise information about critical power/battery conditions. The Value SOHO Series UPS offers home and small office users clean and stable battery backup. The inclusion of a RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. With Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The multifunction LCD readout provides immediate access to precise information about critical power/ battery conditions. 2 1 2 5 3 6 5 6 7 7 1 4 9 8 9 10 11 10 1. Power On/Off Switch 2. Power On Indicator 3. LCD Display 4. Display Select 5. Communication Port to PC (Serial) 6. Communication Port to PC (USB) 7. Phone/Fax/Modem/DSL Network Protection Ports 8. Circuit Breaker Protection 9. Battery Back up and Surge Protection Outlets 10. AC Input 11. Fuse Protection 4 5 2 4 5 FR socket* 6 6 1 1 8 3 3 8 7 7 1. Power On/Off Switch 2. LCD Display 3. Display Select 4. Communication Port to PC (Serial) 5. Communication Port to PC (USB) 9 6. Phone/Fax/Modem/DSL/Network Protection Ports 7. Battery Back up and Surge Protection Outlets* 8. Circuit Breaker Protection 9. AC Input UK socket* AS socket* *= Other socket types available upon request Technical Specifications Technical Specifications Model Name VALUE600EI VALUE800EI VALUE1000EI VALUE1200EILCD VALUE1500EILCD VALUE2200EILCD Model Name VALUE600ELCD VALUE800ELCD VALUE1000ELCD VALUE1200ELCD VALUE1500ELCD VALUE2200ELCD General General UPS Topology Line-Interactive UPS Topology Line-Interactive Energy Saving Yes Energy Saving Yes Input Input Voltage Voltage 230Vac Input Voltage Range 8A 50/60Hz ± 3Hz (Auto-sensing) Rated Input Current 10A Plug Type 165Vac - 280Vac Input Frequency Range 50/60Hz ± 3Hz (Auto-sensing) Rated Input Current 230Vac Input Voltage Range 165Vac - 280Vac Input Frequency Range 10A (Schuko or FR) or 8A (AS) 10A Plug Type IEC 320 C14 Schuko or NEMA Output Output VA 600 800 1000 Watts 360 480 550 On Battery Waveform 1200 1500 2200 720 900 1320 Outlets - Total 3 1500 2200 720 900 1320 230 Vac ± 10% Yes 50/60Hz ± 1% 2 (Schuko, FR) or 3 (AS) 4 Schuko or FR or AS Outlets - Battery & Surge Protected 6 2 (Schuko, FR) or 3 (AS) 4 Transfer Time 4ms 1200 Simulated Sine Wave Outlet Type 3 Transfer Time 550 Outlets - Total 6 IEC 320 C13 Outlets - Battery & Surge Protected 1000 On Battery Frequency 50/60Hz ± 1% Outlet Type 800 480 Automatic Voltage Regulation (AVR) Yes On Battery Frequency 600 360 On Battery Voltage 230 Vac ± 10% Automatic Voltage Regulation (AVR) VA Watts On Battery Waveform Simulated Sine Wave On Battery Voltage 4ms Battery Battery Runtime at Half Load (min) 8 8 7 8 10 6 Runtime at Half Load (min) 8 8 7 8 10 6 Runtime at Full Load (min) 1 1 1 2 2 1 Runtime at Full Load (min) 1 1 1 2 2 1 Battery Type Battery Type Sealed Lead Acid Battery Quantity 1 2 User Replaceable - Yes Replacement Battery Pack - Replacement Battery Pack Quantity - RBP0084 RBP0085 RBP0086 2 Surge Protection & Filtering Surge Suppression Battery Quantity 1 2 User Replaceable - Yes Typical Recharge Time 8 Hours Replacement Battery Pack - Replacement Battery Pack Quantity - RBP0084 - HID Compliant USB Port Yes LCD Control Panel Yes HID Compliant USB Port Power On, Using Battery Audible Alarms Yes Yes Serial Port - Yes Audible Alarms On Battery, Low Battery, Overload, Fault PowerPanel® Personal Edition Software 1-In, 1-Out Management & Communications Yes Serial Port LED Indicators RBP0086 405 Joules (L-N) Phone / Network Protection RJ11/RJ45 LCD Control Panel RBP0085 2 Surge Suppression 1-In, 1-Out Management & Communications On Battery, Low Battery, Overload, Fault PowerPanel® Personal Edition Software Physical Physical Form Factor Form Factor Tower Tower Physical Size Physical Size Physical - UPS Module Physical - UPS Module Dimensions (WxHxD) (mm.) 100 x 140 x 300 4.6 5.2 Dimensions (WxHxD) (mm.) 140 x 180 x 326 5.5 11.2 13.2 14.5 Weight (kg.) 100 x 140 x 300 4.6 5.2 140 x 180 x 326 5.5 11.2 13.2 14.5 Environmental Environmental Operating Temperature Operating Temperature + 32°F to 104° F / 0° C to 40° C Operating Humidity 0% - 90% non-condensing Storage Relative Humidity 99 BTU/hr - 4°F to 122° F / -20° C to 50° C + 5 °F to 113°F / -15°C to 45 °C 0% - 90% 10% - 95% 102 BTU/hr 109 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 0% - 90% non-condensing 10% - 95% non-condensing Operating Elevation 0-1000 meters Storage Temperature + 32°F to 104° F / 0° C to 40° C Operating Humidity 10% - 95% non-condensing Operating Elevation Online Thermal Dissipation Sealed Lead Acid Surge Protection & Filtering 405 Joules (L-N) Phone / Network Protection RJ11/RJ45 Weight (kg.) 18 167 BTU/hr 198 BTU/hr 0-1000 meters Storage Temperature - 4°F to 122° F / -20° C to 50° C Storage Relative Humidity 225 BTU/hr Online Thermal Dissipation +5 °F to 113°F / -15°C to 45 °C 0% - 90% 99 BTU/hr 102 BTU/hr 10% - 95% 109 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 167 BTU/hr 198 BTU/hr 225 BTU/hr 19 INTELLIGENT LCD SERIES PFC SINEWAVE SERIES Multifunction LCD Readout (Detailed Display) Active PFC Power Supplies Compatible Displays clear and consistent LCD readout of power/battery status including load, runtime, power and other information at a single push-ofa-button. Also, advanced settings can be configured to potential power problems in advance. The PFC Sinewave Series protects equipment with Active PFC power supplies from unexpectedly shutdown or harmful stress when switching from AC power to UPS battery power. Designed for small office/SOHO computers and home entertainment systems, the Intelligent LCD Series features “Best-In-Class” power protection with Automatic Voltage Regulation (AVR) line conditioning to maintain safe power levels for connected equipment without resorting to battery power. The RJ11/RJ45 port ensures phone, fax and modem lines are protected from surges and spikes. The multifunction LCD readout provides immediate access to detailed information relating to critical power/battery conditions. 1 FR socket* 3 6 4 7 8 UK socket* * =Other socket types available upon request The PFC Sineware UPS with pure sine wave output safeguards mid-to high-end computer systems, servers and networking hardware that use conventional and Active Power Factor Correction (PFC) power supplies, while the RJ11/RJ45 port ensures phone, fax and modem lines are protected from surges. Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains a safe voltage level , this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The multifunction LCd readout provides immediate access to detailed information relating to critical power/battery conditions. 1 5 2 1. Power On/Off Switch 2. Power On Indicator 3. LCD Display 4. LCD Display Toggle/Selected Switch 5. Communication Port to PC (USB) 6. Battery Back up and Surge Protection Outlets* 7. Full-Time Surge Protection Outlets* 8. Phone/Fax/Modem/DSL Network Protection Ports 9. AC Input 10. Circuit Breaker Protection 2 8 8 11 11 1. Power On/Off Switch 2. Power On Indicator 3. LCD Module Display 4. Display Switch 5. Silence Alarm Switch 6. Control Switch 7. Battery Charger USB Ports 8. Communication Protection Ports RJ11/RJ45 9. Battery and Surge Protected Outlets 12 3 4 5 6 7 9 14 10 9 10. Circuit Breaker 11. USB Port to PC 12. Serial Port to PC 13. AC Input NEMA socket* UK socket* * =Other socket types available upon request 14 9 10 Technical Specifications Model Name CP900EPFCLCD CP1300EPFCLCD CP1500EPFCLCD General Technical Specifications Model Name CP1050EAVRLCD CP1350EAVRLCD CP1500EAVRLCD UPS Topology Line-Interactive Energy Saving Yes Input Voltage General UPS Topology Line-Interactive Energy Saving Yes 230Vac Input Voltage Range 165Vac - 265Vac Input Frequency Range 50/60Hz ± 3Hz (Auto-sensing) Rated Input current Input Voltage Plug Type 230Vac Input Voltage Range Input Frequency Range 50/60Hz ± 3Hz (Auto-sensing) Rated Input current 10A Plug Type 10A Schuko Schuko or UK or NEMA Output 165Vac - 265Vac VA 900 1300 1500 Watts 540 780 900 On Battery Waveform Schuko or UK Pure Sine Wave On Battery Voltage Output VA 1050 1350 1500 Automatic Voltage Regulation (AVR) Watts 630 810 900 On Battery Frequency On Battery Waveform Outlets - Total Simulated Sine Wave On Battery Voltage Automatic Voltage Regulation (AVR) Yes On Battery Frequency 50/60Hz ± 1% Outlets - Total 6 Outlet Type 230Vac ± 10% Yes 50/60Hz ±1% 6 6 (Schuko, UK) or 8 (NEMA) Schuko Schuko or UK (UK x 2 + IEC x 4) or NEMA Outlets - Battery & Surge Protected 6 3 (UK) or 6 (Schuko) or 8 (NEMA) Outlets - Surge-Only Protected 0 3 (UK) or 0 (Schuko, NEMA) USB Charging Ports - Outlet Type 230Vac ± 10% Yes Transfer Time (Typical) Schuko or FR or UK (UK x 2 + IEC x 4) 4ms Battery Outlets - Battery & Surge Protected 3 Outlets - Surge-Only Protected 3 Runtime at Half Load (min) 7 9 10 4ms Runtime at Full Load (min) 1 2 3 Transfer Time Battery Type Battery Runtime at Half Load (min) 12 10 11 Battery Size Runtime at Full Load (min) 3 2 3 Battery Quantity Battery Type Replacement Battery Replacement Battery Yes Typical Recharge Time RBP0064 RBP0015 Surge Suppression Yes 8 Hours RBP0051 RBP0013 Surge Suppression Yes 1-In, 1-Out (Combo) Management & Communications 1-In, 1-Out (Combo) LCD Control Panel Management & Communications LCD Control Panel Yes HID Compliant USB Port HID Compliant USB Port Yes Serial Port LED Indicators Power On, Wiring Fault Audible Alarms On Battery, Low Battery, Overload Yes Yes - Yes LED Indicators Power On Audible Alarms On Battery, Low Battery, Overload, Fault PowerPanel® Personal Edition Software PowerPanel® Personal Edition Software Physical Physical Form Factor Form Factor Tower Tower Physical Size Physical Size Physical - UPS Module Physical - UPS Module Dimensions (WxHxD) (mm.) Dimensions (WxHxD) (mm.) 100 x 249 x 371 10.3 11.5 12.1 Weight (kg.) 100 x 230 x 275 100 x 265 x 370 6.6 9.5 10.9 Environmental Environmental Operating Temperature Operating Temperature + 32°F to 104° F / 0° C to 40° C + 32°F to 104° F / 0° C to 40° C Operating Humidity 0% - 90% non-condensing Operating Humidity 0% - 90% non-condensing Operating Elevation 0-10000 feet (0-3000 meters) Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Relative Humidity Online Thermal Dissipation RBP0016 405 Joules Phone / Network Protection RJ11/RJ45 1215 Joules Phone / Network Protection RJ11/RJ45 12V/8.5AH 2 Phone Protection RJ11 Surge Protection & Filtering Weight (kg.) 12V/7AH 1 Surge Protection & Filtering 8 Hours RBP0012 12V/8.5AH Typical Recharge Time 2 User Replaceable Sealed Lead Acid User Replaceable Sealed Lead Acid Battery Quantity Storage Relative Humidity 0 - 95% 31 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 41 BTU/hr 61 BTU/hr 20 Online Thermal Dissipation 0 - 95% 31 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 41 BTU/hr 61 BTU/hr The Smart Choice for Business POWERPANEL® BUSINESS EDITION REMOTE MANAGEMENT CAPABILITIES PowerPanel® Business Edition is designed for enterprise-class applications, and gives power users and administrators the tools needed for full local/remote control. This industryleading software is capable of managing all power conditions of workstations and servers electrically-connected to the UPS on the network. Its features include automatic event logging/reporting, notifications, server shutdown and a user-friendly dashboard interface. It also allows for control customisation. These enterprise-level features give administrators the power to fully manage their UPS system and safeguard all connected equipment. PowerPanel® Business Edition software consists of Agent, Client and Center: The Agent - Monitors and configures the UPS through USB or serial connection. It logs UPS status and power events, and gracefully shuts down the hosted computer in response to the event of power failure. The Client - Establishes communication with the Agent and RMCARD, and generates actions when power event occurs. In the event of power failure, each Client will request that the hosted computer shuts down following notifications from the UPS, ensuring computers/devices powered by the UPS are be fully protected. The Center - Simultaneously monitors and controls multiple UPSs and computers with the Agent or Client installed via local network. It also logs events and results about commands for power management. The Smart App UPS Systems feature remote network management capabilities via the PowerPanel® Business Edition software, an optional SNMP/ HTTP remote management card, and an optional ENVIROSENSOR. These management tools enable administrators to perform various operations including remote management, real-time monitoring, UPS configuration and scheduled server/workstations shutdowns. Our Smart App UPS systems and Remote Management Cards have achieved Cisco EnergyWise certified status. This means better support for other Energy-Wise-enabled entities and easier monitoring and control to achieve the best energy to achieve the best energy performance under the EnergyWise operation framework. Our Smart App UPS systems and Remote Management Card has been tested as compatible with Cisco EnergyWise 1.2.0. Go to www.cisco.com/go/compatibledisclaimer for complete disclaimer. Remote Management Card The Remote Management RMCARD is an optional extra that can be added to any Smart App UPS system for remote management and configuration of the UPS via standard web browsers or network management system (NMS).An administrator can access, monitor and perform remote management including UPS scheduled shutdown, startup and reboot; multiple alert notifications by e-mail, SMS, and SNMP trap; flexible event action setting. With its Hot-Swap Capability, the UPS system can remain 100% up and available for connected equipment whilst performing an RMCARD installation or replacement. Product Features • Automatic file-savings, equipment shutdowns and OS hibernation • Scheduled shutdowns, outlet control and restarts • Multiple alert notification options: Email, SMS, Messenger, Alert message box Servers/workstations protected by the UPS must be installed with PowerPanel® Business Edition to enjoy the extra value-added features as below: • UPS Status Notification Ability to define the recipients of event notifications that are on the same domain name as that of the protected servers/workstations. • Real-time UPS monitoring • Remote management and configuration of UPS via Web Browser or NMS • Support auto-shutdown of servers/workstations to protect from data loss due to power failure • Hot-swappable (Plug-n-Play) • Schedule shutdown/start-up/reboot of the UPS via remote control • Event logging to track UPS operational history • Data logging for analysing power conditions • Event notifications via email, SMS and SNMP traps • Support TCP/IP, UDP, SNMPv1/HTTP, TELNET, NTP, DNS, SMTP protocols. (HW1.0 above). Support IPv6, HTTPs, SNMPv3, SSH protocols. (HW2.0 above) • SNMP MIB provided • Quick installation and user friendly interface • User upgradeable firmware via FTP • Security management provided • 10/100 Mbps Ethernet Compatible • Support ENVIROSENSOR to monitor temperature and humidity (*RMCARD 203/303 only) Remote Management Card • Safe Shutdown Operation Configure graceful shutdown procedure for protected servers/workstations. Model Remote Management Auto Shutdown Upgradable User Firmware Auto Event Notification Remote Scheduling Ethernet Speeds (Mbps) Auto Shutdown Clients ENVIROSENSOR Compatible • User Programmable Command File In the event action section, we provide the flexibility to add your own command file to perform a specific/customisable action. RMCARD202 RMCARD203 RMCARD302 RMCARD303 HTTP, NMS Workstations, Multiple Servers v E-mail, SMS, SNMP TRAP Shutdown, Startup, Reboot 10/100 50 N/A v N/A v Environmental Sensor The Environmental Sensor (ENVIROSENSOR) along with the selected Remote Management Card (RMCARD203/303) enables administrators to monitor real-time temperature and humidity readings to ensure all engineering devices are operating under appropriate environmental conditions. Via standard web browsers, administrators can easily monitor not only the ambient temperature and humidity but also the status of connected devices such as door alarms and smoke detector. When a defined event happens, the bundled RMCARD will send notifications to administrators for further offsite management, making it highly applicable for data centres, IT closets and other mission-critical installations. Product Features • Real-time environment monitoring • Remote management and configuration of the sensor via Web Browsers or NMS • Automatic event notifications via e-mail, SMS and SNMP traps • 4 input dry contacts application interface provided • Displays the name and location of the sensor and connected devices Environmental Sensor Model Name Measurement Range and Accuracy Temperature Humidity Communication Connection Port Input Contact Closure Physical Dimensions (L x W x H) (mm) Weight (g) ENVIROSENSOR 0-70°C with accuracy ± 1°C 10-90RH with accuracy ± 2% RJ45 Port 4 59 x 45 x 29 41.5 ONSITE MANAGEMENT CAPABILITY ® PowerPanel Business Edition for Virtual Environments As the trend of virtualisation has transformed the IT industry, the need for power protection comes from not only the physical investments but also virtual IT environments. With PowerPanel® Business Edition, enterprises using VMware ESX 4.1 or later versions can easily manage a UPS powering an ESX/ESXi host platform and virtual machines to monitor UPS status or perform a graceful unattended shutdown along with other advanced features. In addition, PowerPanel® Business Edition can also be installed on the following operation systems: • Windows 8 / 7 / Vista / XP • Windows Server 2012 / Server 2012 R2 / Server 2008 / Server 2008 R2 / Windows 2003 • Hyber-V Server 2012 / Server 2012 R2 • Citrix XenServer 5 or later versions • Linux builds or later versions, e.g. Red Hat Enterprise 5.1 / Fedora 7 / SUSE 10.1 / Debian 5.1 / Ubuntu 9.10 The RELAYIO500 Relay Control Card is a management solution, providing users with the ability for onsite UPS status monitoring and local device control via 5 output relays. In addition, the RELAYIO500 provides 1 input contact to perform a UPS shutdown in battery mode. Product Features • Onsite UPS status monitoring & local device control • 5 contact closures indicating UPS status information • Perform onsite UPS shutdown on battery mode by contact closure input • Hot-swappable (Plug-n-Play) • Quick Installation • Dry Contact Model Name RELAYIO500 Eletrical External S/D Voltage 7.5-12V Power Dissipation 1.35W Max (Default 12V input) Physical Dimensions (W x H x D) (mm) 41.8 x 14.2 x 81 Weight (g) 41.6 Environmental Operating Temperature 0 - 40°C Operating Humidity 0 to 95% Output Relay Rating Maximum Voltage Maximum Current 30VDC / 1255VAC 3A (per relay) SMALL OFFICE PRODUCT INDEX Home & Home Office OFFICE RACKMOUNT SERIES 31 ● GreenPower UPS™ Technology ● Line-Interactive UPS Topology P. ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● Protected On / Off Switch ● Multifunction LCD Readout ● USB & Serial Connectivity Ports ● Hot-Swappable Battery Packs ● User-Replaceable Batteries ● SNMP / HTTP Remote Management Capability (Optional) ● PowerPanel® Business Edition Software 32 P. PROFESSIONAL TOWER SERIES ● GreenPower UPS™ Technology ● Pure Sine Wave Output ● Line-Interactive UPS Topology ● Automatic Voltage Regulation ● EMI, RFI, Surge and Lightning Spike Protection ● Auto-Restart / Auto-Charge ● Emergency Power Off (EPO) Port ● Multifunction LCD Readout ● Detachable LCD Panel ● USB & Serial Connectivity Ports ● User-Replaceable Batteries ● SNMP / HTTP Remote Management Capability (Optional) ● PowerPanel® Business Edition Software HOME THEATER SYSTEM Smart App UPS Systems The Smart App UPS Systems provides an advanced level of protection and local / remote management software that supports mission-critical servers, telecom equipment, VOIP and internet infrastructure. NETWORKING SERVERS WORKSTATIONS CORPORATE DATA CENTER 37 ONLINE S SERIES ● Pure Sine Wave Output ● Rack / Tower Convertible Configuration* ● Critical Load Outlets ● Auto-Restart / Auto-Charge ● Multifunction LCD Readout ● USB & Serial Connectivity Ports ● Hot-Swappable Battery Packs ● Generator Mode Setting* ● Smart Battery Management ● PowerPanel® Business Edition Software MEDIUM BUSINESS PRODUCT INDEX P. ● Online (Double Conversion) UPS Topology ● EMI, RFI, Surge and Lightning Spike Protection ● Phone / Fax / Modem / DSL / Network Protection ● Emergency Power Off (EPO) Port ● Rotatable LCD Indicator* ● Extended Runtime (XL) Models* ● Online Output Voltage Setting* ● Economy Mode Setting ● SNMP / HTTP Remote Management Capability (Optional) *=Select models ONLINE SERIES ● Pure Sine Wave Output ● Online (Double Conversion) UPS Topology ● Rack / Tower Convertible Configuration* ● EMI, RFI, Surge and Lightning Spike Protection ● Critical Load Outlets ● Phone / Fax / Modem / DSL / Network Protection ● Auto-Restart / Auto-Charge ● Emergency Power Off (EPO) Port ● Multifunction LCD Readout ● Rotatable LCD Indicator* ● USB & Serial Connectivity Ports P. ● Extended Runtime (XL) Models ● Hot-Swappable Battery Packs ● Online Output Voltage Setting ● Generator Mode Setting ● Economy Mode Setting ● Smart Battery Management ● Fixed Charging Time with Extended Battery Pack ● Smart Fan Speed Control by Load Level ● SNMP / HTTP Remote Management Capability (Optional) *=Select models ● PowerPanel® Business Edition Software 41 PROFESSIONAL RACKMOUNT SERIES ● GreenPower UPS™ Technology ● Line-Interactive UPS Topology ● Automatic Voltage Regulation ● Critical Load Outlets ● Auto-Restart / Auto-Charge ● Protected On / Off Switch ● Rotatable LCD Indicator* ● Extended Runtime (XL) Models* ● User-Replaceable Batteries ● PowerPanel® Business Edition Software ● Pure Sine Wave Output ● Rack / Tower Convertible Configuration ● EMI, RFI, Surge and Lightning Spike Protection P. ● Phone / Fax / Modem / DSL / Network Protection ● Emergency Power Off (EPO) Port ● Multifunction LCD Readout ● USB & Serial Connectivity Ports ● Hot-Swappable Battery Packs ● SNMP / HTTP Remote Management Capability (Optional) 33 INDUSTRIAL EQUIPMENT *= Select Models FEATURE INDEX FEATURE INDEX MULTIFUNCTION LCD READOUT AUTOMATIC VOLTAGE REGULATION (AVR) AVR AVR INCONSISTENT UTILITY POWER CONSISTENT SAFE POWER Multifunction LCD Readout Compact display. Clear and consistent LCD readout of power/battery status including load, runtime, power and other information at a single push-of-abutton. Also, advanced settings can be configured to send alerts about potential power problems in advance. Automatic Voltage Regulation (AVR) Automatic Voltage Regulation (AVR) stabilises the AC signal and maintains safe voltage for the connected equipment. AVR regulates high and low voltages and brings the power to a nominal 220/240 volts. This allows the UPS to maintain safe power levels without resorting to battery power, which significantly increases battery life and eliminates AC-DC power transfer when minor power fluctuations occur. It also reduces the chances of data loss, memory freezes, and system crashes. Pure Sine Wave PURE SINE WAVE The Smart App UPS System provides mission-critical equipment with the highest level of line clarity- Pure Sine Wave. Distorted power and power anomalies, such as harmonics, high voltage transients and surges, while not as obvious as blackouts, can cause serious equipment performance and reliability problems. When incoming power is abnormal, the Smart App UPS models deliver smooth, sine wave battery output, which ensures equipment continues to operate optimally. Pure sine wave power is required for an increasing number of electronics that utilise Power Factor Corrections (PFC) power supplies. Pure Sine Wave Benefits: • Servers: Operates at optimal specifications. • Electronic Equipment: Extends equipment life (such as VOIP, PBX) by running cooler and more efficient. • Telecommunications: Eliminates disrupting static, or hum in telecommunication equipment. • Sensitive Electronics: Operates properly and retains settings. • Commercial/Professional Audio/Video: Power noise is eliminated, removing lines in television screens and hum in sound systems. Comparison Table OR Series PRT Series PR Series Form Waveform Factor Rack Mount Simulated Sine Wave Tower Pure Sine Wave RM/T Pure Sine Wave OLS Series RM/T, Tower Pure Sine Wave v - OL Series RM/T, Tower Pure Sine Wave v - Model *= Select Models LCD AVR v v v v v v Watt 600-1500 750-3000 750-6000 360-900 675-2700 500-4500 Load/Current Level AVR in Use* Overload Silent Mode Static Frequency Tolerance* Temperature (F and C)* Runtime Battery in Use Battery Level Battery Shutdown Voltage* Battery Pack Numbers* Output Frequency* Input Voltage Output Voltage Normal Operation Slew Rate* * = Select Models LCD DISPLAY INFORMATION TABLE Simulated Sine Wave output produces a sine wave that is “stepped” or modified, while Pure Sine Wave output produces a sine wave that is similar to normal AC wall power. Convertible Rack/Tower Configuration The Smart App UPS units can be mounted in either Tower or Rack Mount form to make the most of your workstation space. This configuration option is especially important to give growing organizations, with changing requirements, maximum flexibility. COMPARISON TABLE VA LCD Display Information Table Detailed display. The rotatable LCD readout showcases clear and consistent information about power/battery status including load, runtime, power, AVR and other information at a single push-of-a-button. Also, advanced settings can be configured to send alerts about potential power problems in advance. Outlets 6 6/8/9 6/8/9/10 4/5/6/8/9/ 1000-10000 800-9000 Terminal Block 3/6/8/9/10/ 1000-10000 900-9000 Terminal Block v v v SNMP/ HTTP v v v Home / SOHO / SMEs Home / SOHO / SMEs SMEs / Corporate / Industrial v v v SMEs / Corporate / Industrial v v v SMEs / Corporate / Industrial RJ11/45 USB Software v * v v v v v Designed for CONVERTIBLE RACK/TOWER CONFIGURATION FEATURE INDEX FEATURE INDEX HOT-SWAPPABLE, FRONT-LOAD BATTERIES Hot-Swappable, Front-Load Batteries UPS Extended Runtimes (XL) CyberPower extended runtime (XL) models feature convenient connectors that accept optional external battery packs to provide additional runtime. The external battery packs are easy to plug-in and can be “hot swapped” to ensure your business remains available during normal UPS maintenance. UPS EXTENDED RUNTIMES (XL) When performing battery maintenance, 100% uptime and availability of connected equipment is essential for all enterprises. The Smart App UPS features hot-swappable, front-loaded battery packs that are easy to install and ensure the uptime of connected equipment is maintained during normal battery maintenance. As long as utility power is present, the batteries can be hot-swapped without interrupting power to connected equipment. No special equipment is required for swapping batteries. Simply pull the front cover off and remove the internal battery pack holder with a Phillips screwdriver. Slide the front-loaded battery pack out of the UPS and install the new one back into the unit and secure. Emergency Power Off (EPO) Port A CyberPower UPS system with an Emergency Power Off (EPO) port gives the capability to immediately power down all installed equipment from one single access point by activating a push button. EPO is an essential feature for many applications in industrial, telecommunications and the IT industry to protect against water damage, excessive heat, security breaches, or catastrophic failures. EPO EMERGENCY POWER OFF (EPO) PORT Critical Load Outlets The inclusion of critical load outlets means the transfer of battery power can be reserved to specified outlets during a power overload and administrators can easily prioritise and protect the most valuable equipment and data. Equipment connected to critical load outlets will continue functioning on battery power when utility power is not adequate to power all connected equipment. CRITICAL LOAD OUTLETS RJ11/RJ45 PROTECTION RJ11/RJ45 Protection The RJ11/RJ45 port is designed to protect data lines and communication equipment from AC transients caused by surge, electrostatic discharge and other power abnormalities. 31 OFFICE RACKMOUNT SERIES PROFESSIONAL TOWER SERIES Detachable LCD Panel Hot-Swappable Battery This unique feature can be removed and relocated up to 4.5 feet from the unit so that IT managers can easily access the UPS systems in data centres for quick and efficient power supply management, regardless of location. All Smart App UPS feature hot-swappable batteries which can be easily installed or unplugged during normal battery maintenance without interruption to the UPS operation. The Office Rackmount Series offers users, from SMEs to corporate data centres, clean and stable power supply with the featured RJ11/RJ45 port ensures phone, fax, and modem lines are protected from surges. With Automatic Voltage Regulation (AVR) stabilizes the AC signal and maintains stable voltage, this allows the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The optional SNMP/HTTP Remote Management Capability enables remote management and control of the system via a standard web browser. 2 1 4 3 6 7 8 9 10 Model Name OR600ELCDRM1U OR1000ELCDRM1U OR1500ELCDRM1U General UPS Topology Line-Interactive Energy Saving GreenPower UPS™ Bypass Technology Input Voltage Input Voltage Range 1. Power Switch/Power On Indicator 2. Online Indicator 3. On Battery Indicator 4. Fault 5. Replace Battery Indicator 6. Tab/Status Button 7. Enter/Setup Button 8. Up/Control Button 9. Down/Test Button 10. Esc/Logs Button 11. Battery and Surge Protected Outlets 12. Communication Port to PC (USB) 12 1 2 4 6 Setup Tab Enter 7 Control Test Logs 230Vac 175Vac - 255Vac Input Frequency Range 13. Communication Port to PC (Serial) 14. EPO (Emergency Power Off) Port 15. SNMP/HTTP Network Slot 16. Circuit Breaker 17. AC Input 160Vac - 270Vac PR750ELCD 11 ▲ PR750ELCD IEC 320 C14 Line-Interactive GreenPower UPS™ Bypass Technology Energy Star Qualified Yes Active PFC Compatible Yes 600 1000 1500 360 600 900 Simulated Sine Wave 230Vac ± 10% Automatic Voltage Regulation (AVR) 10A 16A IEC 320 C14 IEC 320 C20 Output VA 750 1000 1500 2200 3000 Watts 675 900 1350 1980 2700 Sine Wave 230Vac ± 5% Automatic Voltage Regulation (AVR) 6 Outlet Type 163Vac - 286Vac 50/60Hz ± 3Hz (Auto-sensing) On Battery Voltage 50/60Hz ± 1% Outlets - Total Yes On Battery Frequency IEC 320 C13 50/60Hz ± 1% Overload Protection Outlets - Battery & Surge Protected 4 Outlets - Total Outlets - Surge-Only Protected 2 Outlet Type On Utility: Circuit Breaker & Internal circuitry limiting / On Battery: Internal Current Limiting 6 8 9 IEC 320 C13 (8) IEC 320 C13, (1) IEC 320 C19 USB Charging Ports N/A Outlets - Battery & Surge Protected Rated Power Factor 0.6 Outlets - Surge-Only Protected Transfer Time (Typical) 4ms Rated Power Factor 0.9 Transfer Time 4ms Battery Runtime at Half Load (min) 12 14 11 Runtime at Full Load (min) 4 4 3 Battery Type Sealed Lead Acid 6V/9AH 2 User Replaceable Hot-Swappable Typical Recharge Time 6V/7AH 6V/9AH 4 4 12 14 17 27 13 4 4 5 10 5 Battery Type Battery Size User Replaceable Sealed Lead Acid 12V/7AH 12V/12AH 12V/17AH RBP0026 Yes Quick Charge: 3 Hours, ECO Mode: 8 Hours RBP0014 RBP0065 RBP0023 1-In, 1-Out (Combo) RBP0024 Surge Suppression 405 Joules Management & Communications LCD Control Panel Yes LCD Control Panel Yes HID Compliant USB Port Yes Detachable LCD Control Panel Option Yes Serial Port Yes HID Compliant USB Port Yes LED Indicators Power On, Wiring fault Audible Alarms On Battery, Low Battery, Overload Software SNMP / HTTP Remote Monitoring Serial Port Yes Emergency Power Off (EPO) Port Yes PowerPanel® Business Edition LED Indicators Power On, On Line, On Battery, Wiring fault, Replace Battery Yes, with optional RMCARD202/203 Audible Alarms On Battery, Low Battery, Overload, Fault Physical PowerPanel® Business Edition Software Form Factor Rack SNMP / HTTP Remote Monitoring Physical Size Yes, with optional RMCARD202/203 Physical Physical - UPS Module Form Factor 430 x 44 x 235 433 x 44 x 389 433 x 44 x 485 8.1 16.1 19.4 Installed Rack Height 1U Physical - UPS Module Weight (kg.) + 32°F to 104° F / 0° C to 40° C Operating Temperature Operating Humidity 0% - 90% non-condensing Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C 20 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 24 BTU/hr 138 x 162 x 349 170 x 221 x 432 170 x 221 x 432 196 x 432 x 513 196 x 432 x 513 12.3 18.9 25.1 52.6 55.5 137 BTU/hr 205 BTU/hr Environmental Operating Temperature 0 - 95% Storage Relative Humidity Tower Physical Size Dimensions (WxHxD) (mm.) Environmental Online Thermal Dissipation RBP0024 Surge Protection & Filtering Management & Communications Weight (kg.) 12V/17AH 4 Yes Typical Recharge Time Replacement Battery 12V/17AH 2 Hot-Swappable 1030 Joules Phone / Network Protection RJ11/RJ45 9 0 Runtime at Half Load (min) Yes Surge Protection & Filtering Surge Suppression 8 Runtime at Full Load (min) Battery Quantity RBP0025 6 Battery Yes 8 Hours RBP0019 PR3000ELCD 230Vac On Battery Waveform Yes On Battery Frequency PR2200ELCD 160Vac - 280Vac Rated Input current Watts On Battery Voltage PR1500ELCD Energy Saving Plug Type On Battery Waveform PR1000ELCD Input Frequency Range VA Dimensions (WxHxD) (mm.) 17 ▲ PR1000ELCD PR1500ELCD ▲ PR2200ELCD/PR3000ELCD UPS Topology Input Voltage Range 10A Plug Type Replacement Battery 16 17 General Voltage Output Battery Quantity 16 16 17 Input 50/60Hz ± 3Hz (Auto-sensing) Rated Input current Battery Size 11 11 9 12 15 15 10 11 Esc 13 15 12 13 14 14 3 5 8 Status 13 14 Technical Specifications Technical Specifications Model Name The Professional Tower Series UPS provides an advanced level of power protection to servers, telecom equipment, VOIP, Internet infrastructure and other mission-critical applications. Featuring Pure Sine Wave output and Automatic Voltage Regulation (AVR) that stabilises the AC signal and maintains stable voltage, it enables the UPS to maintain safe power levels for the connected equipment without resorting to battery power. The optional SNMP/HTTP Remote Management Capability enables remote management and control of the system via a standard web browser. 1. Power On/Off Switch 2. LCD Display 3. LCD Readout Toggle Button 4. Phone/Fax/Modem/DSL Network Protection Ports 5. Circuit Breaker Protection 6. Battery Backup and Surge Protection Outlets 7. Surge Protection Outlets 8. Expansion Port 9. Communication Port to PC (USB & Serial) 10. AC Input 5 32 32°F to 104° F / 0° C to 40° C Operating Humidity 0% - 90% non-condensing Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Relative Humidity 24 BTU/hr Online Thermal Dissipation 0 - 95% 75 BTU/hr 102 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 113 BTU/hr 33 PROFESSIONAL RACKMOUNT SERIES PROFESSIONAL RACKMOUNT SERIES 34 Pure Sine Wave Pure Sine Wave output produces a true sine wave that is similar to normal AC wall power, that which ensures continuous optimal operation. UPS with Pure Sine Wave are designed for electronics utilising Active PFC power supplies or other devices that require pure sine wave for proper function. The Professional Rackmount Series UPS provides an advanced level of power protection to servers, telecom equipment, VOIP, Internet infrastructure and other mission-critical applications. Featuring Pure Sine Wave output and Automatic Voltage Regulation (AVR) that stabilises the AC signal and maintains a safe voltage, it allows the UPS to maintain safe power levels for connected equipment without resorting to battery power. With the optional Extended Runtime (XL) battery packs, the UPS backup time can be extended to maximize workflow flexibility. It can be configured in either Tower (T) or Rack Mount (RM) form to make the most of your workspace. Technical Specifications Model Name PR750ELCDRT1U PR1000ELCDRT1U PR1000ELCDRT2U PR1500ELCDRT2U PR2200ELCDRT2U PR3000ELCDRT2U General Technical Specifications Model Name PR1000ELCDRTXL2U PR1500ELCDRTXL2U PR2200ELCDRTXL2U PR3000ELCDRTXL2U PR5000ELCDRTXL5U PR6000ELCDRTXL5U General UPS Topology Line-Interactive UPS Topology Line-Interactive Energy Saving GreenPower UPS™ Bypass Technology Energy Saving GreenPower UPS™ Bypass Technology Active PFC Compatible Yes Active PFC Compatible Input Yes Input Voltage 220/230/240Vac Voltage 220/230/240Vac Input Voltage Range 160Vac – 288Vac Input Voltage Range 160Vac – 288Vac Input Frequency Range 50/60Hz ± 0.1Hz Rated Input Current Input Frequency Range 10A Plug Type 16A IEC 320 C14 IEC 320 C20 50/60Hz ± 0.1Hz Rated Input Current 10A Plug Type Output 16A IEC 320 C14 32A IEC 320 C20 Terminal Block Output VA 750 1000 1000 1500 2200 3000 VA 1000 1500 2200 3000 5000 6000 Watts 500 670 700 1000 1600 2250 Watts 750 1125 1650 2400 4000 4500 On Battery Waveform Sine Wave On Battery Voltage Automatic Voltage Regulation (AVR) 6 IEC 320 C13 Outlets - Battery & Surge Protected IEC 320 C13 10 IEC 320 C13 6 IEC 320 C13 8 Outlets - Critical Load 2 Outlets - Non-Critical Load (NCL) 4 (1) IEC320 C19, (9) IEC320 C13 On Utility: Circuit Breaker / On Battery: Internal Circuitry Limiting Outlets - Total Outlet Type 10 IEC 320 C13 9 (1) IEC320 C19, (9) IEC320 C13 IEC 320 C13 (1) IEC320 C19, (8) IEC320 C13 11 (8) IEC 320 C13, (2) IEC 320 C19, (1) Terminal Block (8) IEC 320 C13, (2) IEC 320 C19, (1) Terminal Block 10 Outlets - Battery & Surge Protected 10 9 11 4 Outlets - Critical Load 4 3 6 6 Transfer Time 50/60Hz ± 0.1% Overload Protection 8 IEC 320 C13 Yes On Battery Frequency On Utility: Circuit Breaker / On Battery: Internal Circuitry Limiting Outlets - Total 220/230/240Vac ± 5% Automatic Voltage Regulation (AVR) 50/60Hz ± 0.1% Overload Protection Sine Wave On Battery Voltage Yes On Battery Frequency Outlet Type On Battery Waveform 220/230/240Vac ± 5% Outlets - Non-Critical Load (NCL) 4ms 6 5 Transfer Time Battery 4ms Battery Runtime at Half Load (min) 23 14 32 18 16 8 Runtime at Half Load (min) 40 22 13 8 31 28 Runtime at Full Load (min) 7 5 11 6 6 3 Runtime at Full Load (min) 18 8 5 3 12 10 Battery Type Battery Size Battery Quantity Sealed Lead-Acid Battery Type 6V/9AH 6V/9AH 12V/7AH 12V/7AH 12V/9AH 12V/9AH 4 4 4 4 4 4 User Replaceable Hot-Swappable Typical Recharge Time Extended Battery Module User Replaceable Yes Hot-Swappable 12V/9AH 12V/9AH 12V/9AH 12V/9AH 12V/9AH 12V/9AH 4 4 4 4 16 16 Yes Yes Typical Recharge Time - BPE48V75ART2U RBP0027 Battery Quantity Yes 6 Hours Replacement Battery Battery Size Sealed Lead-Acid RBP0030 RBP0037 RBP0040 Surge Protection & Filtering 6 Hours Extended Battery Module BPE48V75ART2U Replacement Battery BPL48V75ART2U RBP0040 RBP0044 / RBP0045 Surge Protection & Filtering Surge Suppression 810 Joules Phone Protection RJ11 Surge Suppression - Yes Phone / Network Protection RJ11/RJ45 810 Joules Phone Protection RJ11 1-In, 1-Out (Combo) Yes Phone / Network Protection RJ11/RJ45 Management & Communications 1-In, 1-Out (Combo) Management & Communications LCD Control Panel Yes LCD Control Panel Yes HID Compliant USB Port Yes HID Compliant USB Port Yes Serial Port Yes Serial Port Yes Emergency Power Off (EPO) Port Yes Emergency Power Off (EPO) Port Yes LED Indicators Power On LED Indicators Power On Audible Alarms On Battery, Low Battery, Overload Audible Alarms On Battery, Low Battery, Overload PowerPanel® Business Edition Software SNMP / HTTP Remote Monitoring SNMP / HTTP Remote Monitoring Physical Yes, with optional RMCARD202/203 Physical Form Factor Rack Form Factor Physical Size Rack Physical Size Physical - UPS Module Physical - UPS Module Dimensions (WxHxD) (mm.) Weight (kg.) PowerPanel® Business Edition Software Yes, with optional RMCARD202/203 430 x 44 x 490 17.6 Installed Rack Height 433 x 88 x 388 18 25.5 433 x 88 x 480 27 1U 30 37 2U Dimensions (WxHxD) (mm.) Weight (kg.) 433 x 88 x 480 30.8 Installed Rack Height Environmental 433 x 88 x 630 34.5 34.9 42 2U 103.5 5U Environmental Operating Temperature 32 °F to 104 °F / 0 °C to 40 °C Operating Temperature 32 °F to 104 °F / 0 °C to 40 °C Operating Humidity 0% - 95% non-condensing Operating Humidity 0% - 95% non-condensing Operating Elevation 0-10000 feet (0-3000 meters) Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Relative Humidity Online Thermal Dissipation 433 x 220 x 645 101.5 0 - 95% 49 BTU/hr 72 BTU/hr 64 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. Storage Relative Humidity 139 BTU/hr 218 BTU/hr 337 BTU/hr Online Thermal Dissipation 0 - 95% 99 BTU/hr 170 BTU/hr 228 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 385 BTU/hr 410 BTU/hr 490 BTU/hr 35 PROFESSIONAL RACKMOUNT SERIES 3 4 1 PROFESSIONAL RACKMOUNT SERIES 2 ▲ PR750ELCDRT1U/PR1000ELCDRT1U ▲PR1000ELCDRTXL2U/PR1500ELCDRTXL2U/PR2200ELCDRTXL2U/ PR3000ELCDRT2U/PR3000ELCDRTXL2U 5 18 3 11 13 15 17 10 6 8 16 1 2 4 ▲PR1000ELCDRTXL2U/PR1500ELCDRTXL2U 8 10 6 ▲PR2200ELCDRTXL2U/PR3000ELCDRT2U ▼ PR2200ELCDRT2U 5 5 11 15 PR1000ELCDRT2U/ ▼ PR1500ELCDRT2U 17 11 15 ▼ PR3000ELCDRTXL2U 18 6 17 10 PR1000ELCDRT2U/ PR1500ELCDRT2U/ ▼ PR2200ELCDRT2U 6 13 14 3 1 5 2 7 1. Power On/Off Switch 2. Power On Indicator 3. Multifunction LCD Readout 4. LCD Readout Toggle Button 5. Battery Backup, Surge Protected & AVR Protected Outlets (Critical/Non-Critical) 12 18 13 14 12 4 ▼ PR5000ELCDRTXL5U/PR6000ELCDRTXL5U 16 6. AC Inlet 7. Output Terminal Block 8. Output Circuit Breaker 9. Input Terminal Block 10. Input Circuit Breaker 11. USB Port to PC 8 10 9 17 18 16 13 11 15 14 12 12. Surge Protected Communication Ports - RJ11/RJ45 13. Serial Port/Serial Port I (Primary) 14. Serial Port II (Secondary) 15. EPO (Emergency Power Off) Port 16. Extended Runtime (XL) Battery Pack Connector 17. SNMP/HTTP Network Slot 18. Ground Stud External Battery Packs Model Name BPE48V75ART2U BPL48V75ART2U 220-240V 100-240V 60A 100A General Voltage Amperage E ▼ BPE48V75ART2U C B A D Battery Battery Type Sealed Lead-Acid Battery Size Battery Quantity 12V/9AH 8 12 Typical Recharge Time 6 Hours Built-in Charger Yes Expansion Ready (Daisy-chain) Yes Physical Dimensions (WxHxD) (mm.) Weight (kg.) 433 x 88 x 480 433 x 88 x 630 31.2 45.3 Environmental Operating Temperature Operating Humidity 32 °F to 104 °F / 0 °C to 40 °C 0% - 90% non-condensing Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Relative Humidity 0% - 95% non condensing Compatible Models Compatible Models PR3000ELCDRT2U PR1000ELCDRTXL2U PR1500ELCDRTXL2U PR2200ELCDRTXL2U PR3000ELCDRTXL2U PR5000ELCDRTXL2U PR6000ELCDRTXL2U F G B A. On-board User-Replaceable Fuse Cover B. External Battery Pack Input Socket C. External Battery Pack Output Socket D. DC Circuit Breaker* C ▲ BPL48V75ART2U E . AC Circuit Breaker F . AC Output Outlet G . AC Input Inlet * = Select Models 36 37 ONLINE S SERIES ONLINE S SERIES Online Double Conversion Topology Ultimate Protection Online Double Conversion Topology Online Double Conversion Topology provides an extra layer of insulation from power problems, achieved by continuously operating off battery power and having zero transfer time during power outages. It also stabilises output frequency and voltage, eliminates any line noise that may be apparent in industrial settings or when operating off generator power. OLS1000E OLS1500E OLS2000E OLS3000E OLS1000EXL OLS1500EXL Double-Conversion Energy Saving ECO Mode Efficiency > 95% OLS2000EXL OLS3000EXL Yes 160Vac - 300Vac 190Vac - 300Vac 160Vac - 300Vac 190Vac - 300Vac 40Hz - 70Hz Rated Input Current 10A 16A 10A Input Power Factor 0.98 Cold Start Yes Plug Type IEC C14 IEC C14 1500 2000 3000 Watts 800 1200 1600 2400 On Battery Waveform Outlets - Total Outlet Type OLS3000ERT2U OLS1000ERTXL2U Double-Conversion ECO Mode Efficiency > 95% OLS1500ERTXL2U OLS2000ERTXL2U OLS3000ERTXL2U Yes Voltage 230Vac Input Voltage Range 160Vac - 300Vac 190Vac - 300Vac 160Vac - 300Vac 10A 16A 1500 2000 3000 800 1200 1600 2400 IEC C20 VA 1000 1500 2000 3000 1000 1500 2000 3000 800 1200 1600 2400 800 1200 1600 2400 Overload Protection Sine Wave 208, 220, 230, 240Vac (Configurable) On Battery Frequency 4 5 6 4 4 5 6 (2+2) IEC320 C13, (1) Terminal Block (1) IEC320 C19, (2+2) IEC320 C13, (1) Terminal Block IEC320 C13 IEC320 C13 (2+2) IEC320 C13, (1) Terminal Block (1) IEC320 C19, (2+2) IEC320 C13, (1) Terminal Block IEC C20 Watts AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120% Bypass Mode: Warning only @ 130%>Load>105%, Shutdown immediately @ Load>130% IEC320 C13 IEC C14 Output On Battery Voltage 4 16A Yes IEC C14 On Battery Waveform IEC320 C13 10A 0.98 Plug Type 1000 190Vac - 300Vac 40Hz - 70Hz Cold Start IEC C20 208, 220, 230, 240Vac (Configurable) Overload Protection OLS2000ERT2U Energy Saving 50/60Hz ± 0.5% (Auto-Sensing or Configurable) On Battery Frequency OLS1500ERT2U UPS Topology Rated Input Current Sine Wave On Battery Voltage OLS1000ERT2U Input Power Factor IEC C20 1000 Model Name Input Frequency Range 16A Output VA Technical Specifications Input 230Vac Input Voltage Range *=Select Models Active PFC Compatible Input Input Frequency Range Smart Battery Management (SBM) is an intelligent management procedure that can prevent premature wear-out of the batteries. By charging the batteries in several phases with different current levels, SBM can eliminate over-charged situations. Furthermore, when combined with the temperature compensation feature, SBM dramatically reduces the deterioration of battery capacity caused by exhaust heat during a working cycle. General UPS Topology Voltage Smart Battery Management (SBM) The Economy Mode Setting increases the operating efficiency of UPS, by up to 95% under ECO mode, while also generating less BTU heat output and reducing operating energy costs. General Active PFC Compatible By selecting the generator as an input power source, the Online Series will co-exist with household power generator, whilst ensuring the output power quality without sacrificing any protection. Economy Mode Setting Technical Specifications Model Name Generator Mode Setting* CyberPower Smart App Online Systems provide continuous, consistent and clean Pure Sine Wave power to mission-critical equipment, regardless of the incoming power conditions. The Online Double Conversion Topology provides an extra layer of insulation from power problems which is achieved by continuously operating off battery power and having zero transfer time during power outages. It also stabilises output frequency and voltage and eliminates any line noise that may be apparent in industrial settings or when operating off generator power. Featuring Online Double Conversion UPS topology, the Online S Series UPS provides the highest level of power protection and a guaranteed quality power supply to demanding businesses that value manageability and performance. This series features numerous engineering excellences including Economy Mode Setting, Smart Battery Management and Generator Mode Setting, all to further enhancing its capability. With its zero transfer time, the Online S Series ensures continuous, consistent and clean Pure Sine Wave power to all mission-critical equipment. Outlets - Total Outlet Type 50/60Hz ± 0.5% (Auto-Sensing or Configurable) AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120% Bypass Mode: Warning only @ 130%>Load>105%, Shutdown immediately @ Load>130% 6 6 8 9 6 6 8 9 (3+3) IEC320 C13 (3+3) IEC320 C13 (4+4) IEC320 C13 (1) IEC320 C19, (4+4) IEC320 C13 (3+3) IEC320 C13 (3+3) IEC320 C13 (4+4) IEC320 C13 (1) IEC320 C19, (4+4) IEC320 C13 Outlets - Battery & Surge Protected 4 4 5 6 4 4 5 6 Outlets - Battery & Surge Protected 6 6 8 9 6 6 8 9 Outlets - Critical Load 4 4 5 6 4 4 5 6 Outlets - Critical Load 6 6 8 9 6 6 8 9 Rated Power Factor 0.8 Rated Power Factor 0.8 Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load Transfer Time 0ms Transfer Time Battery 0ms Battery Runtime at Half Load (min) 16 14 16 14 Depends on external batteries Runtime at Half Load (min) 16 14 16 14 Depends on external batteries Runtime at Full Load (min) 6 5 6 5 Depends on external batteries Runtime at Full Load (min) 6 5 6 5 Depends on external batteries 12V/9AH 12V/7AH 12V/9AH 12V/7AH Battery Type Battery Size Sealed Lead-Acid 12V/7AH Battery Quantity 12V/9AH 3 Battery Type 12V/7AH 12V/9AH 6 12V/7AH 12V/9AH 3 User Replaceable 6 Depends on external batteries BPSE36V45A 12V/9AH 3 12V/7AH BPSE72V45A BPSE36V45A BPSE72V45A 5 Hours Depends on external batteries Yes Extended Battery Module 440 Joules Phone Protection RJ11 BPSE36V45ART2U BPSE72V45ART2U BPSE36V45ART2U Surge Suppression Yes Phone / Network Protection RJ11/RJ45 BPSE72V45ART2U 440 Joules Phone Protection RJ11 1-In, 1-Out Yes Phone / Network Protection RJ11/RJ45 Management & Communications 1-In, 1-Out Management & Communications LCD Control Panel Yes LCD Control Panel Yes HID Compliant USB Port Yes HID Compliant USB Port Yes Serial Port Yes Serial Port Yes Emergency Power Off (EPO) Port Yes Emergency Power Off (EPO) Port Yes Audible Alarms Audible Alarms ® PowerPanel Business Edition Software SNMP / HTTP Remote Monitoring Yes Yes ® PowerPanel Business Edition Software Yes, with optional RMCARD302 / RMCARD303 SNMP / HTTP Remote Monitoring Physical Yes, with optional RMCARD302 / RMCARD303 Physical Form Factor Tower Form Factor Physical Size Rack/Tower Physical Size Physical - UPS Module Physical - UPS Module Dimensions (WxHxD) (mm.) 151 x 225 x 394 13.1 196 x 337 x 416 15.3 Installed Rack Height 23.8 28.2 - - Dimensions (WxHxD) (mm.) - Weight (kg.) - 438 x 88 x 430 13.2 438 x 88 x 610 14.6 Installed Rack Height Physical - Power Module 21.2 27.6 - 2U - Physical - Power Module Dimensions (WxHxD) (mm.) - Weight (kg.) - Power Module Rack Height - 151 x 225 x 394 7.7 196 x 337 x 416 7.8 12.2 12.6 - Physical - Battery Module Dimensions (WxHxD) (mm.) - Weight (kg.) - Power Module Rack Height - 438 x 88 x 430 8.4 438 x 88 x 610 8.5 11.6 12 2U Physical - Battery Module Dimensions (WxHxD) (mm.) 151 x 225 x 394 17.2 196 x 337 x 416 17.2 34.2 151 x 225 x 394 34.2 Battery Module Rack Height 17.2 196 x 337 x 416 17.2 34.2 Dimensions (WxHxD) (mm.) 34.2 - Weight (kg.) 438 x 88 x 430 24.2 438 x 88 x 610 24.2 34.7 438 x 88 x 430 34.7 Battery Module Rack Height Environmental 24.2 438 x 88 x 610 24.2 34.7 34.7 420 BTU/hr 666 BTU/hr 1126 BTU/hr 2U Environmental Operating Temperature 32 °F to 104 °F / 0 °C to 40 °C Operating Temperature 32 °F to 104 °F / 0 °C to 40 °C Operating Humidity 20% ~ 90% non-condensing Operating Humidity Operating Elevation 0-5000 feet (0-1500 meters) Operating Elevation 0-5000 feet (0-1500 meters) Storage Temperature -4 °F to 122 °F / -20 °C to 50 °C Storage Temperature -4 °F to 122 °F / -20 °C to 50 °C Storage Relative Humidity Online Thermal Dissipation 12V/9AH 6 Surge Protection & Filtering Surge Suppression Weight (kg.) 12V/7AH 3 Yes Smart Battery Management (SBM) Mode Surge Protection & Filtering 12V/9AH 6 Typical Recharge Time Yes Extended Battery Module 12V/7AH User Replaceable 5 Hours Smart Battery Management (SBM) Mode Battery Size Battery Quantity Yes Typical Recharge Time Weight (kg.) 38 10% to 90% 342 BTU/hr 420 BTU/hr 666 BTU/hr 1126 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 20% ~ 90% non-condensing Storage Relative Humidity 342 BTU/hr 420 BTU/hr 666 BTU/hr 1126 BTU/hr Online Thermal Dissipation 10% to 90% 342 BTU/hr 420 BTU/hr 666 BTU/hr 1126 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 342 BTU/hr 39 ONLINE S SERIES ONLINE S SERIES 40 Technical Specifications Model Name OLS6000E OLS6000EXL OLS10000E OLS10000EXL UPS Topology Double-Conversion Energy Saving ECO Mode Efficiency > 96% Active PFC Compatible 7 1 General 220-240Vac Input Voltage Range 176Vac - 276Vac Input Frequency Range 9 11 3 2 Yes Input Voltage 6 8 3 2 1 5 50/60Hz ± 10% (Auto-sensing) Rated Input Current 27.3A 45.5A Input Power Factor 0.99 Cold Start Yes Plug Type Terminal Block 12 Output VA 6000 10000 Watts 5400 9000 On Battery Waveform Outlets - Total Terminal Block Rated Power Factor 0.9 Harmonic Distortion THD < 2% at Linear Load, < 5% at Non-linear Load Transfer Time 7 6 ▲OLS1000ERT2U/ERTXL2U/OLS1500ERT2U/ERTXL2U 7 Runtime at Half Load (min) 15 Depends on external batteries 11 Depends on external batteries 5 Depends on external batteries 4 Depends on external batteries 12V/9AH - Sealed Lead-Acid Battery Quantity Typical Recharge Time - 20 - 20 - Depends on external batteries 7 Hours Depends on external batteries Yes Extended Battery Module BPSE240V47A Management & Communications LCD Control Panel Yes HID Compliant USB Port Yes Serial Port Yes Emergency Power Off (EPO) Port Yes LED Indicators Yes Audible Alarms Yes SNMP / HTTP Remote Monitoring 1 2 3 4 5 6 7 8 Yes, with optional RMCARD302 / RMCARD303 Physical Form Factor Tower Physical Size Physical - UPS Module Dimensions (WxHxD) (mm.) 260 x 708 x 550 Weight (kg.) 70 25 86 28 Environmental Operating Temperature 32 °F to 104 °F / 0 °C to 40 °C Operating Humidity 0% - 90% non-condensing Operating Elevation 0-3281 feet (0-1000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Relative Humidity Online Thermal Dissipation 0% - 95% non-condensing 1603 BTU/hr 1603 BTU/hr 12 12 4 4 13 14 2672 BTU/hr 2672 BTU/hr Power On/Off Button Function Buttons Multifunction LCD Readout Input Circuit Breaker Battery Backup & Surge Protected Outlets Serial Port USB Port Surge Protected Communication Ports RJ45/RJ11 9 10 11 12 13 14 15 16 15 13 ▲OLS2000E/OLS2000EXL PowerPanel® Business Edition Software 17 5 5 7 Hours Smart Battery Management (SBM) Mode 9 8 0ms 12V/7AH 16 10 2 Runtime at Full Load (min) Battery Size 6 11 9 11 Battery Battery Type ▲OLS3000ERT2U/ERTXL2U 7 6 3 1 Outlet Type ▲OLS2000ERT2U/ERTXL2U 11 4 1 50/60Hz ± 0.05Hz AC Mode: Warning only @ 110%>Load>105%, Transfer to bypass after 60sec @ 120%>Load>110%, Transfer to bypass immediately@ Load>120% Battery Mode: Warning only @ 110%>Load>105%, Shutdown after 10sec @ 120%>Load>110%, Shutdown immediately @ Load>120% Bypass Mode: Warning only @ 130%>Load>105%, Shutdown immediately @ Load>130% Overload Protection 8 ▲OLS1000E/OLS1500E/OLS1000EXL/OLS1500EXL 208, 220, 230, 240Vac (Configurable) On Battery Frequency 10 12 4 Sine Wave On Battery Voltage 5 10 9 ▲OLS3000E/OLS3000EXL 4 SNMP/HTTP Network Slot Extended Runtime Battery Module Connector Emergency Power Off Connector 13 AC Input Inlet Terminal Block Output Circuit Breaker Maintenance Switch Dry Contact (Optional) ▲OLS6000E/OLS6000EXL ▲OLS10000E/OLS10000EXL 17 Parallel Port External Battery Packs #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners External Battery Packs Model Name BPSE36V45ART2U BPSE72V45ART2U BPSE36V45A BPSE72V45A BPSE240V47A Voltage 36V 72V 36V 72V 240V Amperage 40A 40A 40A 40A 25A(6K) / 42A(10K) B General Battery Battery Type Sealed Lead-Acid Battery Size Battery Quantity 12V/7AH 6 12 6 User Replaceable Yes Hot-Swappable Yes Typical Recharge Time Replacement Battery Pack Quantity 20 - Input Connector On-board Replaceable Fuse Cover Output Connector Output Terminal Block Input Terminal Block E C Depends on external charger Expansion Ready (Daisy-chain) Replacement Battery Pack 12 A B C D E Yes - Power plugs for Module RBP0068 RBP0071 - 1 1 - 438 x 88 x 430 438 x 88 x 610 151 x 225 x 394 196 x 337 x 416 260 x 718 x 550 24.2 34.7 17.2 34.2 105 Physical Dimensions (WxHxD) (mm.) Weight (kg.) Environmental Operating Temperature B 32 °F to 104 °F / 0 °C to 40 °C Operating Humidity 0% - 90% non-condensing Operating Elevation 0-5000 feet (0-1500 meters) Storage Temperature -4 °F to 104 °F / -20 °C to 40 °C Storage Relative Humidity B C A A A B C C 0% - 90% non condensing Compatible Models Compatible Models OLS1000ERT2U; OLS1500ERT2U OLS1000ERTXL2U; OLS1500ERTXL2U OLS2000ERT2U; OLS3000ERT2U OLS2000ERTXL2U; OLS3000ERTXL2U OLS1000E; OLS1500E OLS1000EXL; OLS1500EXL OLS2000E; OLS3000E OLS2000EXL; OLS3000EXL OLS6000EXL OLS10000EXL ▲BPSE36V45ART2U/BPSE72V45ART2U ▲BPSE36V45A ▲BPSE72V45A ▲BPSE240V47A 41 ONLINE SERIES ONLINE SERIES Smart Battery Management (SBM) Online Output Voltage Setting Smart Battery Management (SBM) is an intelligent management procedure that can prevent premature wear-out of the batteries. By charging the batteries in several phases with different current levels, SBM can eliminate over-charged situations. Furthermore, when combined with the temperature compensation feature, SBM dramatically reduces the deterioration of battery capacity caused by exhaust heat during a working cycle. Online Double Conversion Topology Online Double Conversion Topology provides an extra layer of insulation from power problems, achieved by continuously operating off battery power and having zero transfer time during power outages. It also stabilises output frequency and voltage, eliminates any line noise that may be apparent in industrial settings or when operating off generator power. The Online Series provides real-time adjustable output voltage level setting that allows more flexibility for different application scenarios. Users can select from 200V, 208V, 220V, 230V and 240V simply by few button clicks of the control panel. Generator Mode Setting By selecting the generator as an input power source, the Online Series will coexist with household power generator, whilst ensuring the output power quality without sacrificing any protection. Dual Input* The Online Series when equipped with dual AC input (also known as “HotStandby”) ensures greater availability of the UPS. This feature delivers a secondary source of AC input as the backup supply for when the major input source is down. Together with dual UPS application, it can ensure high-quality output power even under bypass mode. Featuring Online Double Conversion UPS topology, the Online Series UPS provides the highest level of power protection and a guaranteed quality power supply to demanding businesses that value manageability and performance. This series features numerous engineering excellences including Economy Mode Setting, Smart Battery Management and Generator Mode Setting, all to further enhancing its capability. With its zero transfer time, the Online Series ensures continuous, consistent and clean Pure Sine Wave power to all mission-critical equipment. 42 Detachable PDU* For seamless and efficient maintenance or replacement, selected models are available with detachable PDU to allow the engineer to configure, repair or replace the UPS unit more easily without shutting down connected servers. Technical Specifications Smart Fan Speed Control by Load Level Model Name Economy Mode Setting The system will automatically adjust the fan speed by monitoring the current operating status including the load level, operating temperature and other factors to enable safe, stable and more energy-saving operation. OL6000ERT3UD OL6000ERT3UDM OL8000ERT3UD OL8000ERT3UDM OL10000ERT3UD The Economy Mode Setting increases the operating efficiency of UPS, by up to 95% under ECO mode, while also generating less BTU heat output and reducing operating energy costs. UPS Topology Double-Conversion Energy Saving ECO Mode Efficiency >95% Energy Star Qualified Yes Active PFC Compatible Yes Voltage OL1500ERTXL2U OL2000ERTXL2U OL3000ERTXL2U OL1000EXL OL1500EXL OL2000EXL OL3000EXL General UPS Topology Double-Conversion Energy Saving ECO Mode Efficiency >93% Active PFC Compatible Yes Voltage 200 - 240Vac 120Vac – 139Vac for 0 – 60% Load, 140Vac – 159Vac for 0 – 70% Load, 160Vac – 179Vac for 0 – 80% Load, 180Vac – 189Vac for 0 – 90% Load, 190Vac – 300Vac for 0 – 100% Load Input Frequency Range Rated Input Current 50/60Hz ± 10Hz (Auto-sensing) 5A 7.5A 10A 15A 5A Input Power Factor 7.5A 10A 15A 0.99 Cold Start 120Vac – 139Vac for 0 – 25% Load, 140Vac – 159Vac for 0 – 50% Load, 160Vac – 179Vac for 0 – 75% Load, 180Vac – 280Vac for 0 – 100% Load Input Frequency Range 50/60Hz ±10Hz (Auto-sensing) Rated Input Current 30A 40A Input Power Factor 0.99 Cold Start Yes Plug Type Terminal Block 50A 30A 40A 50A VA 6000 8000 10000 6000 8000 10000 Watts 5400 7200 9000 5400 7200 9000 On Battery Waveform Sine Wave On Battery Voltage 200, 208, 220, 230, 240Vac (Configurable) ±2% On Battery Frequency 50/60Hz (auto-sensing or configurable) ± 0.25Hz Overload Protection Yes Plug Type OL10000E Output Input Input Voltage Range OL8000E 200 - 240Vac Input Voltage Range OL1000ERTXL2U OL6000E Input Technical Specifications Model Name OL10000ERT3UDM General IEC C14 IEC C20 IEC C14 IEC C20 1.8 3 1.8 3 Outlets - Total Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec; Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec 4 1 4 1 4 1 11 (1) IEC320 C19, (2) IEC320 C13, (1) Terminal Block Terminal Block (1) IEC320 C19, (2) IEC320 C13, (1) Terminal Block Terminal Block (1) IEC320 C19, (2) IEC320 C13, (1) Terminal Block Terminal Block (2) IEC320 C19, (8) IEC320 C13, (1) Terminal Block VA 1000 1500 2000 3000 1000 1500 2000 3000 Outlets - Battery & Surge Protected 4 1 4 1 4 1 11 Watts 900 1350 1800 2700 900 1350 1800 2700 Outlets - Critical Load 2 1 2 1 2 1 6 Outlets - Non-Critical Load (NCL) 2 0 2 0 2 0 5 Cord Length (m) Output On Battery Waveform Sine Wave On Battery Voltage On Battery Frequency Overload Protection 200, 208, 220, 230, 240Vac (Configurable) ± 2% Rated Power Factor 0.9 50/60Hz (auto-sensing or configurable) ± 0.25Hz Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load Transfer Time Line Mode: 105~125% Load for 1 min, 126~150% Load for 10 sec; Battery Mode: 105~130% Load for 10 sec, 131~150% Load for 2 sec Outlets - Total 8 Outlet Type (8) IEC320 C13 (1) IEC320 C19, (8) IEC320 C13 8 Outlets - Critical Load 4 5 Outlets - Non-Critical Load (NCL) 4 4 (9) IEC320 C13 (1) IEC320 C19, (8) IEC320 C13 9 Rated Power Factor 6 5 3 4 15.8 13.5 13.5 12.5 12.5 15.8 13.5 12.5 5.3 5.3 5.5 5.5 4.3 4.3 5.3 5.5 4.3 18 9 18 9 Runtime at Full Load (min) 6 3 6 3 Battery Type 14 9 14 9 4 3 4 3 12V/9AH Battery Quantity 12V/7AH 3 12V/9AH 6 12V/7AH 12V/9AH 3 User Replaceable 20 BPE36V60ART2US BPE72V60ART2US RBP0074 RBP0076 BPE240V50ART3US RBP0073 RBP0072 1,780 Joules BPE36V60AS RBP0075 1,335 Joules BPE72V60AS RBP0074 RBP0079 1,780 Joules Phone / Network Protection RJ11/RJ45 RBP0078 1,335 Joules 1-In, 1-Out (Combo) Management & Communications LCD Control Panel Yes Yes (Requires a separate DB26 Cable) HID Compliant USB Port Yes Serial Port Yes Power On (White), Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red) Audible Alarms Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery PowerPanel® Business Edition Yes, with optional RMCARD302 / RMCARD303 Physical Yes Serial Port Yes Form Factor Emergency Power Off (EPO) Port Yes Physical Size Rack/Tower Power On (White), Line Mode (Green), Battery Mode (Yellow), Bypass Mode (Yellow), Fault (Red), Replace Battery (Red) Audible Alarms Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery Dimensions (WxHxD) (mm.) Weight (kg.) PowerPanel® Business Edition Installed Rack Height Yes, with optional RMCARD302 / RMCARD303 Physical - Power Module 433 x 264 x 660 Rack/Tower Tower Physical Size 265 x 600 x 660 100 Dimensions (WxHxD) (mm.) Physical Form Factor Tower Physical - UPS Module Yes (Configurable, [I/P Power Fail] [Battery Low] [Summary Alarm] [UPS On Bypass] [UPS Fail]) LED Indicators SNMP / HTTP Remote Monitoring Yes (Configurable, [I/P Power Fail] [Battery Low] [Summary Alarm] [UPS On Bypass] [UPS Fail]) LED Indicators HID Compliant USB Port Software Yes Dry Contacts SNMP / HTTP Remote Monitoring Yes (Requires a separate DB26 Cable) Dry Contacts 102 95 97 6U - 433 x 132 x 660 - Weight (kg.) 24 - Installed Rack Height 3U - Physical - Battery Module Physical - UPS Module 433 x 88 x 430 433 x 88 x 600 167 x 232 x 397 212 x 338 x 410 18 32 16 32 Weight (kg.) Installed Rack Height 2U Dimensions (WxHxD) (mm.) Weight (kg.) 433 x 132 x 660 - 76 Installed Rack Height - 78 - 3U - Environmental Environmental Operating Temperature Operating Temperature 32 °F to 104 °F / 0 °C to 40 °C 32 °F to 104 °F / 0 °C to 40 °C Operating Humidity 0% - 90% non-condensing Operating Humidity 0% - 90% non-condensing Operating Elevation 0-10000 feet (0-3000 meters) Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Relative Humidity Online Thermal Dissipation RBP0072 2,430 Joules Software Yes Detachable LCD Control Panel Option BPE240V30AS RBP0073 1-In, 1-Out (Combo) Emergency Power Off (EPO) Port Surge Suppression 5 Hours Surge Protection & Filtering Detachable LCD Control Panel Option Surge Protection & Filtering Dimensions (WxHxD) (mm.) BPE240V30ART3US LCD Control Panel Yes Replacement Battery 4 Hours Management & Communications 5 Hours Smart Battery Management (SBM) Mode 12V/9AH Yes Phone / Network Protection RJ11/RJ45 Yes Typical Recharge Time 5 Hours Smart Battery Management (SBM) Mode Extended Battery Module 12V/7AH Yes 4 Hours Surge Suppression 6 Yes Hot-Swappable 12V/9AH Yes Replacement Battery Sealed Lead-Acid Battery Size 12V/7AH Battery Quantity User Replaceable Typical Recharge Time Runtime at Half Load (min) Sealed Lead-Acid Hot-Swappable 0ms Battery Extended Battery Module 15.8 Runtime at Full Load (min) Battery Size THD < 3% at Linear Load, < 5% at Non-linear Load Transfer Time Runtime at Half Load (min) Battery Type 0.9 Harmonic Distortion 0ms Battery 9 Outlets - Battery & Surge Protected Outlet Type Storage Relative Humidity 0% - 95% non-condensing 341 BTU/hr 512 BTU/hr 759 BTU/hr 1139 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners 341 BTU/hr 512 BTU/hr 759 BTU/hr 1139 BTU/hr Online Thermal Dissipation 0% - 95% non-condensing 1823 BTU/hr 2430 BTU/hr #All specifications are subject to change without notice. ©2014 CyberPower Systems. All Trademarks are the property of their owners. 3038 BTU/hr 1823 BTU/hr 2430 BTU/hr 3038 BTU/hr 43 ONLINE SERIES ONLINE SERIES ▼OL1/1.5/2/3K Model Rackmount Model 1 2 Tower Model 3 8 10 9 14 5 ▼OL1/1.5/2/3K Model 1 2 6 8 11 2 10 7 9 11 14 5 4 12 11 7 13 6 12 3 1 ▲ OL1000ERTXL2U/OL1500ERTXL2U 7 13 9 4 13 8 10 8 ▲ OL2000ERTXL2U 14 1 2 10 9 9 3 4 UPS Status/Fault/Replace Battery 3 4 5 6 7 8 13 14 15 16 17 18 19 20 21 Multifunction LCD Readout Function Buttons Input Circuit Breaker Input/Output Terminal Block Output Circuit Breaker Battery Backup & Surge Protected Outlets 9 10 Serial Port USB Port 5 6 7 8 9 10 11 Surge Protected Communication Ports- Tower Model 5 6 Multifunction LCD Readout Function Buttons Input Circuit Breaker Battery Backup & Surge 12 5 14 14 Serial Port USB Port Surge Protected Communication Ports- RJ11/RJ45 10 11 12 12 ▲ OL2000EXL Relay Output Connector SNMP/HTTP Network Slot Extended Runtime Battery Pack Connector 13 ▲ OL3000EXL EPO (Emergency Power Off) Connector 14 AC Input Inlet 11 12 Remote Control Port Relay Output Connector SNMP/HTTP Network Slot 1 Extended Runtime Battery Pack Connector 2 3 4 17 13 EPO (Emergency Power Off) Connector Backfeed Protection Connector 16 Maintenance Bypass Switch 14 1 2 11 10 9 3 4 5* 6 7 8 DC Input Connector On-board Replaceable Fuse Cover 18 9 10 7 16 16 17 17 15 15 UPS Status/Fault/Replace Battery 8 12 Surge Protected Communication Ports- RJ11/RJ45 13 14 15 Multifunction LCD Readout Function Buttons Input Circuit Breaker Input/Output Terminal Block Relay Output Connector SNMP/HTTP Network Slot Extended Runtime Battery Pack Connector 16 Output Circuit Breaker Battery Backup & Surge Protected EPO (Emergency Power Off) Connector 17 18 Outlets 5* 12 13 14 Power Button/Power On Indicator LED Indicator DC Output Cable 9 10 11 18 11 3 4 5 6 ▼OL6/8/10K Model * Input Circuit Breaker for 6000VA units in 3UD/3UDM model. 12 13 14 UPS Status/Fault/Replace Battery LED Indicator 13 Protected Outlets 15 5 ▲ External Battery Packs for RM Model: BPE240V30ART3US/BPE240V50ART3US 5 Power Button/Power On Indicator Remote Control Port RJ11/RJ45 LED Indicator 7 7 8 9 6 OL1500EXL 11 12 8 10 ▲ OL1000EXL/ ▼OL6/8/10K Model Power Button/Power On Indicator 13 11 6 ▲ OL3000ERTXL2U 1 2 7 6 14 Rackmount Model 44 Serial Port Backfeed Protection Connector Maintenance Bypass Switch USB Port 5* Input Circuit Breaker for 6000E model. 15 6 ▲ 3UD Model OL6000ERT3UD/OL8000ERT3UD/ OL10000ERT3UD ▲ 3UDM Model OL6000ERT3UDM/OL8000ERT3UDM/ OL10000ERT3UDM 20 19 21 ▲ OL6000E/OL8000E/OL10000E 20 19 21 External Battery Packs External Battery Packs Model Name BPE36V60ART2US BPE72V60ART2US BPE36V60AS BPE72V60AS 36V 72V 36V 72V BPE240V30ART3US BPE240V50ART3US A BPE240V30AS D General Voltage Amperage 60A A B F Fuse Cover 240V 30A 50A 30A B C Battery Battery Type Sealed Lead-Acid Battery Size Battery Quantity Sealed Lead-Acid 12V/9AH 6 12V/7AH 12 6 12V/7AH 12 12V/9AH 40 Yes - Yes - Hot-Swappable Yes - Yes - Replacement Battery Pack Replacement Battery Pack Quantity RBP0077 - 2 RBP0073 - RBP0072 2 BPE72V60ART2US C B B - C B F Physical Dimensions (WxHxD) (mm.) Weight (kg.) 433 x 88 x 430 433 x 88 x 660 167 x 232 x 397 212 x 336 x 414 23 44 23.5 43.5 433 x 132 x 660 76 265 x 600 x 660 78 D A 135 A Environmental Operating Temperature 0% - 90% non-condensing Operating Elevation 0-10000 feet (0-3000 meters) Storage Temperature 5 °F to 113°F / -15°C to 45 °C Storage Relative Humidity ▲ BPE240V30ART3US/ BPE240V50ART3US 0% - 95% non condensing Compatible Models Compatible Models E 32 °F to 104 °F / 0 °C to 40 °C Operating Humidity OL1000ERTXL2U; OL1500ERTXL2U OL2000ERTXL2U; OL3000ERTXL2U OL1000EXL; OL1500EXL OL2000EXL; OL3000EXL OL6000ERT3UD; OL6000ERT3UDM OL8000ERT3UD; OL8000ERT3UDM; OL10000ERT3UD; OL10000ERT3UDM C B DC Input Connector C ▲ BPE36V60ART2US/ A Yes - Power plugs for Module RBP0074 DC Output Cable 12V/7AH 20 User Replaceable Expansion Ready (Daisy-chain) On-board Replaceable OL6000E; OL8000E; OL10000E A C ▲ BPE36V60AS ▲ BPE72V60AS ▲ BPE240V30AS 45INDUSTRY TERMS Alternating Current (AC) The flow of electric charge in a circuit that is constantly being reversed back and forth. Amp (ampere, A) The standard unit of measure for electrical current, defined as the amount of electrical flow equal to one coulomb per second. Apparent Power The product of the applied voltage and current in an AC circuit. Blackout A power failure in which line voltage drops to zero. Brownout A drop in voltage in electrical power supply. Buck/Boost Full automatic voltage regulation in a UPS that stabilises low voltage (boost) and high voltage (buck) to maintain nominal 230V power, without resorting to battery power when minor power fluctuations occur. Coaxial Cable Cables that are made of an inner conductor surrounded by an insulator and a shield that are generally used for TV antennas, satellite dishes, cable modems and certain computer networking applications. INDUSTRY TERMS Half-Load The midpoint in the maximum load capacity for a UPS. Hard-wired High amperage devices that require installation by a qualified electrician to be directly wired-in, instead of simply being plugged in to an outlet. Hertz (Hz) The unit for frequency, defined as the number of cycles per second. Hot-Swappable Battery A term used to describe the functions of replacing a UPS battery without shutting down the unit. Joule A measure of electrical energy — one joule is defined as the energy needed to pass one ampere of current through one ohm of resistance. Line-Interactive UPS Functions the same as a standby UPS, with the additional feature of some voltage regulation built in. It switches to battery power when voltage drops too low, just as a standby UPS does, however if the voltage only drops slightly, a line-interactive UPS corrects this without using battery power. The functionality of these mid- to high-grade units falls between standby and online UPS units. Current The flow of electric charge, measured in amps. Load The amount of power consumed by an electrical device on a circuit. Load capacity is a critical factor in selecting a UPS or surge protector. DHCP Dynamic Host Configuration Protocol (DHCP), automatically assigns an IP address to a device on a network. MOV Metal Oxide Varistor is an electronic component that is used to protect circuits against excessive, short-lived, voltages. Direct Current (DC) The unidirectional flow of a electric charge. Nominal Voltage The standard voltage for a circuit or system. Common nominal voltages in the U.S. include 120VAC, 208VAC and 240VAC; while nominal voltage in the EU is 230VAC. Double-Conversion UPS This high-end UPS system converts incoming utility AC power into DC power and then back into AC power, charging connected devices with the UPS battery. The isolated process ensures clean and stable output voltage and zero transfer time. This UPS system is ideal for equipment sensitive to power fluctuations such as corporate data centres, servers, and network and storage devices. Efficiency (Energy Conversion Efficiency) The ratio between the amount of apparent power and the amount of true power used by an electrical device. The closer the true power value is to the apparent power, the more efficient the device. Electromagnetic Interference (EMI) Commonly referred to as line noise, these interference signals can disrupt or degrade the performance of a circuit by inserting abnormalities into the system. Also referred to as radio frequency interference (RFI) when in high or radio frequency. Frequency The number of cycles in a given time period, which is measured in Hertz. Ground An electrical system connection that serves as a conduit between the circuit and earth. Overvoltage This occurs when incoming voltage is higher than normal, but not high enough to be classified as a surge. Power Factor (PF) The ratio of real power (watts) to apparent power (VA), expressed as a number between 0 and 1. Watts divided by VA = Power Factor Power Factor Correction Controls the incoming power to a power supply in order to bring the power factor as close to unity power as possible. Radio Frequency Interference (RFI) See Electromagnetic Interference. Real Power The amount of power being drawn by a system, measured in watts. Real power is a function of VA (apparent power) and the power factor. RJ11, RJ14, RJ45 The abbreviation of registered jack (RJ) – RJ11 is for standard phone lines, RJ14 is for multiple phone lines and RJ45 is for Ethernet. Runtime The maximum period of time battery power is output from a UPS to its connected devices during a power interruption. Runtime is dependent upon the total load of all connected equipment. Simulated Sine Wave A modified or approximated sine wave AC power output. Simulated (or nonsinusoidal) waveforms may also be referred to as a squared sine wave, modified sine wave, trapezoidal sine wave or quasi sine wave. USB (HID Compliant) Universal Serial Bus devices are used to connect various components to a computer. An HID (Human Interface Device) compliant USB follows a specific protocol for communication that allows it to be used with virtually any system. Volt (V) The difference in electric potential between two points when one amp of current dissipates one watt of power. Sine Wave A smooth, repetitive oscillation of AC power. Volt-Ampere (VA) The unit used to express apparent power. Single Phase Power Refers to the distribution of alternating current electric power using a system in which all the voltages of the supply vary in unison. Voltage Regulator A device or component that normalizes voltage to a certain standard when it is fluctuating. SMTP Simple Mail Transfer Protocol is the standard for e-mail transmission on the Internet. Watt (W) A unit of measure for true power consumption. SNMP Simple Network Management Protocol is a commonly used protocol for devices to communicate over a network. Spike A spike is a sudden, brief power surge, usually lasting less than 1ms. Standby UPS A UPS that passes utility power straight through to the output when conditions are stable, but switches to battery power when utility voltage drops below an acceptable level. Surge Periods when line voltage increases dramatically, typically lasting longer than 1ms, but less than a few seconds, though they can last longer. Total Harmonic Distortion (THD) A calculated measure of the reduction in sine wave clarity caused by stray wave frequencies. Thermal Dissipation The process of dissipating heat from an electrical system via air or liquid cooling; also a term for the amount of heat a device can emit. Transfer Time The time it takes UPS to switch from AC power to battery power. Transformer A device that converts AC line voltage to a higher or lower value. U The standard unit of measure for rack-mounted equipment. A device measuring 1U is 1.75 inches (44.45mm) high, 2U is 3.50 inches (88.9mm), etc. Undervoltage Related to both brownout and voltage sag, undervoltage falls between these two, occurring when voltage is lower than normal for an extended period of time without recovering, but not too low that the electronic device will not function. Waveform Is a representation (or form) of how alternating current (AC) varies with time. Common waveform representations include sine wave, square wave and trapezoidal wave. An instrument called an oscilloscope can be used to visually represent a wave as a repeating image on a screen. Wiring-Fault Refers to an abnormal flow of current that is due to an improperly grounded electrical outlet. CyberPower Systems Inc.