Preview only show first 10 pages with watermark. For full document please download

документация Cysy357_dat_e

   EMBED


Share

Transcript

Body Ported Valves Series SY3/5/7/9000 Body Ported Valves Series ® SY3/5/7/9000 Features Wide range of sizes Choice of electrical entries Body ported valves can be manifold mounted One touch fittings for direct connection How to Order SY 5 1 20 5 LO Q 01F Symbols Series 3 5 7 9 2 position single SY3000 SY5000 SY7000 SY9000 1 A, B port size Type of actuation 1 2 position single 2 2 position double 3 3 position closed centre 4 3 position exhaust centre 5 3 position pressure centre DC 5 6 V S R 24 12 6 5 3 VDC VDC VDC VDC VDC Symbol M5 01F 02F 03F C4 C6 C8 C10 C12 Rated voltage AC ( 50 60 Hz) 1 100 VAC 2 200 VAC 3 110 VAC [115 VAC] 4 220 VAC [230 VAC] Description SY3000 SY5000 SY7000 SY9000 M5 thread 1 8 thread 1 4 thread 3 8 thread 4mm tube 6mm tube 8mm tube 10mm tube 12mm tube 2 position double 2 3 position closed centre 3 3 position exhaust centre 4 3 position pressure centre Electrical entry Grommet 24, 12, 6, 5, 3 VDC L plug connector M plug connector G: Lead wire LO: Without length 300 mm connector MO: Without connector 5 24, 12 VDC/ 100, 110, 200, 220 VAC DIN terminal Y: DIN plug ∗ D: DIN plug ∗ Note: AC voltages can only be specified in conjunction with a DIN plug (Y entry). Manual override + Nil: Non-locking push type 24, 12, 6, 5, 3 VDC M8 connector WO: Without connector cable D: Push-turn locking slotted type E: Push-turn locking lever type Note: For connector cables see Cable appendix. ∗ ''D'' denotes a DIN plug DIN43650 class with industry standard pin spacing. The ''Y'' plug is externally identical but has DIN 43650C pin spacing of 8 mm. Light/Surge voltage suppressor Electrical entry for G, L, M, W Nil Z U CAD CD-ROM AVAILABLE Electrical entry for Y Without light/surge voltage suppressor With light/surge voltage suppressor With light/surge voltage suppressor (Non-polar type) CATALOGUE ES11-83A AVAILABLE Nil Z PDF AVAILABLE ONLINE Without light/surge voltage suppressor With light/surge voltage suppressor Page 39 Valves Very low power consumption Series SY3/5/7/9000 Body Ported Valves Valve Specifications Series Fluid 2 position single Internal pilot 2 position double Operating pressure range (MPa) 3 position Ambient and fluid temperature (˚C) 2 position single, double Max. operating frequency (Hz) 3 position Manual override (Manual operation) Pilot exhaust method Lubrication Mounting orientation Enclosure SY9000 SY7000 Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 –10 to 50 (No freezing) 10 5 5 5 3 3 3 3 Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type Common exhaust type for main and pilot valve Not required Unrestricted Dustproof (DIN terminal, M8 connector comform to IP65) SY3000 SY5000 Valves Solenoid Specifications Electrical entry DC AC 50 60 Hz Allowable voltage fluctuation (%) Standard Power consumption (W) DC Coil rated voltage (V) Apparent power (VA) DIN terminal (Y) Grommet (G) M8 connector (W) L plug connector (L) M plug connector (M) 24, 12, 6, 5, 3 100, 110, 200, 220∗ ±10% of rated voltage 0.35 (With indicator light: 0.4 DIN terminal with indicator light: 0.45) 100 V 110 V 200 V 220 V [230 V] AC Surge voltage suppressor Indicator light 1.4 1.6 2.3 2.5 [2.7 (With (With (With (With (With indicator indicator indicator indicator indicator light: light: light: light: light: 1.5) 1.7) 2.4) 2.6) 2.8)] Diode (DIN terminal is ZNR. G, L or M (Non-polar) is zener diode.) LED ∗ DIN plug only. Response Time SY3000 SY7000 Response time (ms) (at the pressure of 0.5 MPa) Type of Without light/surge With light/surge voltage suppressor actuation voltage suppressor Type Z Type U 15 or less 12 or less 12 or less 2 position single 10 or less 13 or less 10 or less 2 position double 15 or less 20 or less 16 or less 3 position SY5000 Response time (ms) (at the pressure of 0.5 MPa) Without light/surge With light/surge voltage suppressor voltage suppressor Type Z Type U 38 or less 33 or less 31 or less 2 position single 27 or less 30 or less 28 or less 2 position double 50 or less 56 or less 50 or less 3 position Type of actuation SY9000 Response time (ms) (at the pressure of 0.5 MPa) Type of Without light/surge With light/surge voltage suppressor actuation voltage suppressor Type Z Type U 26 or less 19 or less 19 or less 2 position single 18 or less 22 or less 18 or less 2 position double 32 or less 38 or less 32 or less 3 position Response time (ms) (at the pressure of 0.5 MPa) Without light/surge With light/surge voltage suppressor voltage suppressor Type Z Type U 41 or less 35 or less 35 or less 2 position single 35 or less 41 or less 35 or less 2 position double 62 or less 64 or less 62 or less 3 position Type of actuation SY Valve Accessories Mounting Bracket Assemblies for Body Ported Valve Description Type F1 part no. 3 5 7 3 5 7 Bracket (Type F1) SX 000-16-2A (with mounting screw) for single solenoid valves only Bracket (Type F2) SX 000-16-1A (with mounting screw) Type F2 Page 40 Body Ported Valves Series SY3/5/7/9000 Series SY5000 71 20 60 78 15 67 13 101 81 20 94 56 0.76 0.30 0.19 0.65 0.39 0.17 74 15 13 63 87 C6 0.76 0.55 0.24 0.60 0.33 0.16 Onetouch fitting 0.65 0.32 0.16 0.64 0.31 0.17 77 for ø6 0.77 0.34 0.21 0.61 0.34 0.16 20 90 Port size Flow characteristics Type of 14/2 (PA/B) 4/25/3 (A/BEA/EB) 1, 5, 3 4, 2 actuation C (dm3/ C (dm3/ (P, EA, EB) (A, B) (s·bar) ) b Cv (s·bar) ) b Cv 2 Single 1.9 0.35 0.49 2.4 0.39 0.61 position Double Closed 1.7 0.43 0.45 1.8 0.35 0.46 centre 18 2.5 0.32 0.59 3 Exhaust 1.5 0.44 0.41 (1.5) (0.43) (0.40) position centre 2.2 0.46 0.61 Pressure centre (0.91) (0.58) (0.28) 1.8 0.38 0.46 2 Single 0.75 0.43 0.20 0.85 0.64 0.30 position Double Closed C4 0.74 0.40 0.19 0.84 0.57 0.28 centre One3 Exhaust touch fitting 0.75 0.36 0.19 0.84 0.64 0.30 position centre (0.84) (0.53) (0.27) for ø4 0.78 0.44 0.21 Pressure centre (0.71) (0.37) (0.18) 0.84 0.57 0.27 2 Single position Double Closed centre 3 Exhaust position centre Pressure centre 2 Single position Double Closed centre 3 Exhaust position centre Pressure centre 1 8 1.5 0.33 0.33 2.0 0.37 0.52 C6 1.3 0.31 Onetouch fitting 1.3 0.33 for ø6 1.7 0.31 (0.80) (0.47) 0.33 1.6 0.32 0.39 C8 1.6 0.29 Onetouch fitting 1.4 0.38 for ø8 2.2 0.32 (1.6) (0.44) 0.39 1.7 0.38 0.46 84 Weight (g) Response W Grom- times DIN M8 met (m/s) terminal connector 70 26 93 97 88 22 135 143 93 94 26 117 121 111 22 159 167 88 26 112 116 106 22 153 161 1.8 0.35 0.44 0.33 (1.4) (0.37) (0.35) 111 38 158 166 0.42 (0.23) 1.7 0.33 0.44 80 26 103 107 1.9 0.21 0.45 2.3 0.29 0.57 98 22 145 153 2.0 0.37 0.52 0.39 (1.5) (0.41) (0.43) 103 38 150 158 0.56 (0.44) 1.8 0.41 0.50 Note 1: The weights given are for grommet entry and M8 plug. L/M connector and DIN plug weights fall between these options. Note 2: Response time is 0.5MPa with Z type surge suppression. CAD CD-ROM AVAILABLE Port size Flow characteristics Type of 14/2 (PA/B) 4/25/3 (A/BEA/EB) 1, 5, 3 4, 2 actuation C (dm3/ C (dm3/ (P, EA, EB) (A, B) (s·bar) ) b Cv (s·bar) ) b Cv 2 Single 7.0 0.33 1.7 7.6 0.35 2.0 position Double Closed 6.7 0.37 1.7 6.4 0.34 1.6 centre 14 8.3 0.41 2.2 3 Exhaust 6.4 0.36 1.6 (4.1) (0.27) (0.91) position centre 8.0 0.27 1.8 6.5 0.22 1.4 Pressure centre (3.2) (0.34) (0.76) 2 Single 8.0 0.29 1.9 8.0 0.33 2.0 position Double Closed 7.9 0.33 1.9 6.6 0.27 1.6 centre 38 140 148 117 38 164 172 Port size Flow characteristics Weight (g) Type of Response 14/2 (PA/B) 4/25/3 (A/BEA/EB) W 1, 5, 3 4, 2 Grom- times DIN M8 3 3 actuation C (dm / C (dm / (P, EA, EB) (A, B) met (m/s) terminal connector b Cv b Cv (s·bar) ) (s·bar) ) 2 Single 101 38 125 129 4.1 0.23 0.93 3.3 0.33 0.81 position Double 120 30 167 175 Closed 2.9 0.31 0.70 2.4 0.38 0.63 centre 14 3 Exhaust 2.5 0.39 0.65 3.4 0.35 0.82 128 56 175 183 position centre Pressure 4.3 0.23 0.97 2.2 0.39 0.58 centre 107 38 131 135 2 Single 1 (P) 3.2 0.26 0.77 3.2 0.37 0.82 position Double Port 126 30 174 182 Closed 1 4 C8 2.6 0.24 0.63 2.4 0.31 0.62 centre One3 Exhaust 5, 3 touch fitting 2.4 0.25 0.57 2.6 0.42 0.70 134 56 182 190 position centre (EA, EB) for ø8 Pressure port 3.3 0.28 0.78 2.2 0.34 0.60 centre 1 8 103 38 126 130 2 Single 3.8 0.26 0.86 3.2 0.34 0.82 position Double 122 30 169 177 Closed C10 2.8 0.27 0.67 2.4 0.21 0.59 centre One3 Exhaust touch fitting 2.5 0.25 0.59 2.7 0.38 0.70 130 56 177 185 position centre for ø10 Pressure 3.8 0.25 0.89 2.3 0.38 0.61 centre 3 Exhaust position centre Pressure centre Single 2 position Double Closed centre 1 4 3 Exhaust position centre Pressure centre 2 Single position Double Closed centre 3 Exhaust position centre Pressure centre 2 Single position Double Closed centre 3 Exhaust position centre Pressure centre CATALOGUE ES11-83A AVAILABLE 38 Weight (g) Response W Grom- times DIN M8 met (m/s) terminal connector 241 41 265 269 260 41 308 316 284 64 332 340 236 41 260 264 255 41 303 311 8.7 0.34 2.2 8.0 0.33 1.9 (8.3) (0.40) (2.3) 279 64 327 335 8.9 0.34 2.2 6.5 0.25 1.5 (3.3) (0.40) (0.82) 293 41 317 321 4.3 0.28 0.96 7.1 0.32 1.7 312 41 360 368 C8 4.3 0.31 Onetouch fitting 4.3 0.3 for ø8 4.4 0.35 (3.2) (0.26) 0.99 6.1 0.28 1.4 C10 5.9 0.30 Onetouch fitting 5.8 0.25 for ø10 6.3 0.29 (3.2) (0.29) 1.4 6.5 0.26 1.5 C12 6.9 0.24 Onetouch fitting 6.6 0.23 for ø12 7.4 0.25 (3.2) (0.34) 1.6 7.0 0.33 1.7 7.4 0.36 1.9 0.99 (3.8) (0.29) (0.86) 336 64 384 392 1.0 2.1 0.41 0.53 (0.71) 279 41 303 307 6.1 0.28 1.4 7.9 0.33 1.9 298 41 346 354 8.4 0.33 2.0 1.3 (4.1) (0.27) (0.93) 322 64 370 378 1.5 6.4 0.25 1.5 (0.72) 265 41 289 293 7.0 0.25 1.6 8.6 0.41 2.2 284 41 332 340 9.4 0.48 2.6 1.4 (4.5) (0.32) (1.0) 308 64 356 364 1.7 6.6 0.23 1.5 (0.74) PDF AVAILABLE ONLINE Page 41 Valves 2 Single position Double Closed centre 3 Exhaust position centre Pressure centre Weight (g) Response W Grom- times M8 met (m/s) connector 51 15 57 68 13 82 Series SY7000 Port size Flow characteristics Type of 14/2 (PA/B) 4/25/3 (A/BEA/EB) 1, 5, 3 4, 2 3 actuation C (kdm / C (kdm3/ (P, EA, EB) (A, B) (s·bar)) b Cv (s·bar) ) b Cv 2 Single 0.61 0.44 0.16 0.64 0.45 0.18 position Double Closed 0.48 0.46 0.13 0.47 0.43 0.13 centre M5 3 Exhaust 0.47 0.42 0.13 0.47 0.41 0.13 position centre Pressure 0.50 0.48 0.15 0.47 0.43 0.13 centre 2 Single 0.72 0.29 0.18 0.64 0.34 0.17 position Double Closed C4 0.59 0.28 0.15 0.59 0.30 0.15 centre OneM5 3 Exhaust touch fitting 0.63 0.35 0.16 0.42 0.34 0.11 position centre for ø4 Pressure 0.76 0.42 0.21 0.59 0.29 0.15 centre Series SY9000 Series SY3000 Flow Characteristics/Weight Series SY3/5/7/9000 Body Ported Valves Dimensions: Series SY3000 2 position single Grommet (G): SY3120- G - C4 C6 - Q Foot bracket EA 2- ø1.5 die-cast hole EB -Q 28.5 [35.5] 0.8 10 P C4 C6 25 (15) 2 SY3120- G - M5 19 69.4 [71.6] (P, EA, EB port) For manifold gasket positioning (35) 1.2 (Light/Surge voltage suppressor) - + 13.1 18.5 16.9 25 (32) 28.5 [35.5] (3.2) 7.5 C6: 33.6 38 22.5 31 + - (Lead wire length) 17 66.9 [69.1] G: Approx. 300 8.6 44.7 24 11.6 13.1 2- ø3.2 B (For mounting) A 10.2 SY3120-G-M5-Q 2- ø2.2 21.4 M5 (For manifold mounting) 2-M3 depth 3.5 (For mounting bracket) 16.9 4 9.5 28.5 [35.5] 25 ø6 A, B port 22.5 L plug connector (L): SY3120-L- C4 C6 M plug connector (M): M8 connector (WO): SY3120-M- C4 C6 -Q -Q SY3120-WO - C4 C6 -Q 28.5 [35.5] 22.5 68.5 62 67 [69.2] 22.5 16.9 16.9 18.5 18.5 18.5 (3.2) M8 300 76.8 [79] 39.6 [46.6] 15.5 16.9 C6: 33.6 Page 42 33 (Lead wire length) Approx. 75.9 Approx. 300 (Lead wire length) 13.1 C6: 33.6 (3.2) C6: 33.6 (3.2) 18.5 23.5 Manual override One-touch fitting (A, B port) Applicable tubing O.D.:ø4 22.5 Valves (35.5) (For mounting) C6: 33.6 (3.2) (27) 2- ø3.2 Body Ported Valves Series SY3/5/7/9000 Dimensions: Series SY3000 2 position double Grommet (G): SY3220- G - C4 C6 - Q SY3220- G-M5-Q (For manifold gasket positioning) M5 (35) 2- ø3.2 16.9 C6:33.6 (For mounting) 25 (32) G: Approx. 300 23.5 16.9 (Light/Surge voltage suppressor) - + 88.8 [93.2] (Lead wire length) 44.4 8.6 28.5 [35.5] (35.5) (27) (3.2) (P, EA, EB port) Valves EB 19 13.1 2- ø1.5 die-cast hole 28.5 [35.5] 2 10 0.8 (15) P EA 25 M5 (A, B port) B A 10.2 Manual override One-touch fitting A, B port Applicable tubing O.D.: ø4 : ø6 (For manifold mounting) 2-M3 depth 3.5 (For mounting bracket) 4 9.5 2- ø2.2 21.4 C4 C6 -Q M plug connector (M): SY3220-M- C4 C6 -Q Approx. 300 (Lead wire length) SY3220-L28.5 [35.5] 13.1 39.6 [46.6] SY3220-WO- C4 C6 -Q 33 15.5 79 89 [93.4] 108.6 [113] Approx. 300 (Lead wire length) M8 connector (WO): M8 92 106.8 L plug connector (L): 16.9 16.9 C6:33.6 C6:33.6 (3.2) C6:33.6 (3.2) CAD CD-ROM AVAILABLE 16.9 CATALOGUE ES11-83A AVAILABLE PDF AVAILABLE ONLINE (3.2) Page 43 Series SY3/5/7/9000 Body Ported Valves Dimensions: Series SY3000 M5 (P, EA, EB port) 16.9 C6:33.6 N7:37.4 (3.2) (35) (27) 2- ø3.2 (Light/Surge voltage suppressor) 97.3 [101.7] 44.4 [46.5] 22.2 30.7 8.6 (Lead wire length) - + 13.1 25 28.5 [35.5] Valves (35.5) (32) (For mounting) G: Approx. 300 16.9 23.5 19 For manifold gasket positioning M5 (A, B port) 25 2- ø1.5 die-cast hole 5 28.5 [35.5] P EA 3 SY3 4 20- G -M5-Q (15) 2 10 0.8 3 position closed centre/exhaust centre/pressure centre 3 Grommet (G): SY3 45 20-G- C4 C6 -Q B A 10.2 Manual override One-touch fitting 21.4 (A, B port) Applicable tubing O.D.: ø4, ø5/32" : ø6, ø1/4" 2- ø2.2 (For manifold mounting) 2-M3 depth 3.5 (For mounting bracket) 4 9.5 L plug connector (L): M plug connector (M): SY3 3 SY3 4 20-M- C4 C6 5 3 C4 4 20-L- C6 5 -Q M8 connector (WO): -Q 3 SY3 45 20-WO-C4 C6 -Q 33 15.5 39.6 [46.6] M8 x 1 Approx. 300 54.5 115.3 46 53.4 39.5 44.4 [46.6] 97.5 [101.9] (Lead wire length) 48 Approx. 300 54.3 [56.5] 117.1 [121.5] 13.1 (Lead wire length) 28.5 [35.5] 16.9 16.9 C6: 33.6 Page 44 C6: 33.6 (3.2) (3.2) 16.9 C6: 33.6 (3.2) Body Ported Valves Series SY3/5/7/9000 Dimensions: Series SY5000 2 position single C4 Grommet (G): SY5120-G- C6 -Q Foot bracket C8 1.6 0.8 C8 28.1 [35.1] P 15 (20) EB 1/8 (P, EA, EB port) (4.9) 32.3 1.2 (4.9) 11.6 2- ø3.2 (For mounting) 2-M3 depth 3.5 22.6 16.2 20.5 28.1 [32] 16.7 (For mounting bracket) 1/8 (A, B port) 32.5 36 SY5120- G H -01 -Q 2- ø3.2 (For manifold mounting) 23 14.5 29 ø8 ø6 16.6 Applicable tubing O.D.: ø4 B Manual override 10.5 47 38 12.7 One-touch fitting 63.7 A 40.4 + (Lead wire length) - + A, B port 85.9 [88.1] G: Approx. 300 (Light/Surge voltage suppressor) 12.7 23 20.5 (40.2) 2- ø3.2 (36.7) 28.1 [35.1] (37) 40.4 (For mounting) (45) 88.6 [90.8] 2- ø2.2 die-cast hole For manifold gasket positioning Valves 27.2 22 EA C4 SY5120- G- C6 -Q 32.3 SY5120-D- M8 connector (WO): C4 -Q SY5120-WO-C6 -Q C8 CAD CD-ROM AVAILABLE 20.5 23 40.4 32.6 15.1 M8 65 104.9 87.5 94.9 Pg7 32.3 32.3 (4.9) Applicable cable O.D. ø3.5 to ø7 Approx. 300 (Lead wire length) 81 86 [88.2] 95.8 [98] 32.3 C4 C6 C8 60.9 53.4 42.1 27 39.2 [46.2] 20.5 23 40.4 -Q DIN terminal (D): 32.3 -Q C4 SY5120-M- C6 C8 105.8 28.1 [35.1] 12.7 M plug connector: M Approx. 300 (Lead wire length) SY5120-L- C4 C6 C8 Max. 10 L plug connector: L (4.9) CATALOGUE ES11-83A AVAILABLE 20.5 23 40.4 (4.9) PDF AVAILABLE ONLINE 20.5 23 40.4 (4.9) Page 45 Series SY3/5/7/9000 Body Ported Valves Dimensions: Series SY5000 C4 EB 1/8 (P, EA, EB port) 27.2 2- ø2.2 die-cast hole For manifold gasket positioning 12.7 20.5 28.1 [35.1] 11.6 (40.2) (36.7) Valves 62.8 B A Manual override - + One-touch fitting (A, B port) Applicable tubing O.D. : ø4 : ø6 : ø8 107.2 [111.6] (Lead wire length) (Light/Surge voltage suppressor) 40.4 2- ø3.2 (For mounting) (4.9) (45) (37) G: Approx. 300 (A, B port) 20.5 P 1/8 16.2 28.1 [35.1] EA SY5220-G-01-Q 15 (20) C8 0.8 1.6 Grommet (G): SY5220- G- C6  -Q 14.5 36 2- ø3.2 (For manifold mounting) 2-M3 depth 3.5 22.6 16.7 (For mounting bracket) C4 SY5220-M- C6-Q C8 40.4 Page 46 (4.9) M8 connector (WO): C4 SY5220-D- C6 -Q C8 SY5220-WO- C6 -Q Max. 10 Approx. 300 (Lead wire length) C8 32.6 15.1 M8 x 1 Pg7 65.4 145.2 147 39.2 [46.2] C4 Applicable cable O.D. ø3.5 to ø7 60.9 53.4 42.1 27 20.5 40.4 20.5 DIN terminal (D): 110.4 125.2 M plug connector: M 127 [131.4] 28.1 [35.1] 12.7 Approx. 300 (Lead wire length) C4 SY5220-L- C6 -Q C8 97.4 107.4 [111.8] L plug connector: L (4.9) 20.5 40.4 (4.9) 20.5 40.4 (4.9) 32.5 2 position double Body Ported Valves Series SY3/5/7/9000 Dimensions: Series SY5000 3 position closed centre/exhaust centre/pressure centre 3 C4 Grommet (G): SY5 420-G - C6 -Q C8 3 5 5 (A, B port) 20.5 28.1 [35.1] 0.8 15 (20) 1.6 2- ø2.2 die-cast hole 1/8 16.2 1/8 (P, EA, EB port) 27.2 28.1 [35.1] 20.5 40.4 (Light/Surge voltage suppressor) - + Valves 2- ø3.2 (For mounting) 12.7 (37) (4.9) (45) For manifold gasket positioning (40.2) (36.7) 3 SY5 420- 4 -01-Q 32.5 5 One-touch fitting (A, B port) Applicable tubing O.D.: G: Approx. 300 ø4 ø6 ø8 119.8 [124.2] 53.6 [55.8] 31.4 Manual override 44 11.6 (Lead wire length) 2- ø3.2 14.5 (For manifold mounting) 36 2-M3 depth 3.5 (For mounting bracket) 16.7 22.6 M plug connector: M 3 C4 SY5 420-M- C6 -Q 5 C8 3 C4, N3 SY5 420-D- C6, N7(-F2) 5 C8, N9 3 C4 5 C8 SY5 420-WO- C6 -Q 60.9 53.4 42.1 27 20.5 40.4 (4.9) CAD CD-ROM AVAILABLE (4.9) 15.1 20.5 40.4 CATALOGUE ES11-83A AVAILABLE M8 55.2 62.6 72.6 32.6 67.8 157.8 73.5 Pg7 32.7 139.6 [144] 48.7 53.7 [55.9] 61.3 120 [124.4] Approx. 300 (Lead wire length) 20.5 40.4 (4.9) PDF AVAILABLE ONLINE 137.8 Max. 10 ø3.5 to ø7 39.2 [46.2] 63.5 [65.7] M8 connector (WO): Applicable cable O.D. 159.6 28.1 [35.1] 12.7 20.5 40.4 DIN terminal (D): Approx. 300 (Lead wire length) 3 C4 SY5 420-L- C6 -Q 5 C8 45.3 L plug connector: L (4.9) Page 47 Series SY3/5/7/9000 Body Ported Valves Dimensions: Series SY7000 2 position single Grommet (G): SY7120-G- C8 C10 -Q SY7120-G- C8 C10 -Q 1/8 (EA, EB port) (66) (52) (For mounting) (Light/Surge voltage suppressor) 39.4 47.6 12.5 57 46 16.1 - + One-touch fitting (A, B port) Applicable tubing O.D. : ø8 : ø10 13.6 100.1 [102.3] 77.9 G: Approx. 300 (Lead wire length) - + 16.1 24.5 28 47.6 (5.5) (49.5) (42.5) 31.5 [38.5] Valves 2- ø4.2 101.8 [104] 36 For manifold gasket positioning (5.5) 2- ø2.2 die-cast hole EB 1.2 P EA 19.8 28 38 1/4 (P port) 2 18 0.9 (23.9) 31.5 [38.5] 2- ø4.2 (For mounting) B A 1/4 2-M4 depth 6.5 (For mounting bracket) Page 48 (5.5) 24.5 28 47.6 M8 connector (WO): SY7120-D- C8 C10 -Q SY7120-WO-C8 C10 -Q Applicable cable O.D. ø3.5 to ø7 Max. 10 36 19 79.2 120 Pg7 24.5 28 47.6 (5.5) M8 101.7 109.1 Approx. 300 (Lead wire length) (5.5) 24.5 28 40 DIN terminal (D): 66 58.5 47.2 32.1 42.6 [49.6] 39.4 39.4 SY7120-M- C8 C10 -Q 39.4 39.4 24.5 28 47.6 M plug connector (M): 39.4 -Q 110 [112.2] 31.5 [38.5] 16.1 C8 C10 Approx. 300 (Lead wire length) SY7120-L- 95.2 100.2 [102.4] L plug connector (L) : A, B port 20 7 20 SY7120-G-02-Q 2- ø4.2 (For manifold mounting) 31.5 [38.5] 19 42 119.1 Manual override 24.5 28 47.6 (5.5) Body Ported Valves Series SY3/5/7/9000 Dimensions: Series SY7000 2 position double -Q Grommet (G): SY7220-G-C8 C10 SY7220- G-02-Q 1/4 EB 1/8 (EA, EB port) 36 For manifold gasket positioning (For mounting) (Light/Surge voltage suppressor) 24.5 47.6 (49.5) (42.5) 31.5 [38.5] 2- ø3.2 Valves (66) (52) 16.1 2- ø2.2 die-cast hole P (5.5) EA 24.5 40 (P port) (A, B port) 31.5 [38.5] 2 18 0.9 (23.9) 1/4 20 - + One-touch fitting (A, B port) Applicable tubing O.D.: ø8 ø10 (Lead wire length) 13.6 121.4 [125.8] 77 G: Approx. 300 B A 19 42 Manual override 2-M4 depth 6.5 (For mounting bracket) 7 20 2- ø4.2 (For manifold mounting) SY7220-M- C8 C10 -Q SY7220-D- C8 C10 -Q CAD CD-ROM AVAILABLE 111.6 121.6 [126] 141.2 [145.6] (5.5) Approx. 300 (Lead wire length) 24.5 47.6 M8 connector (WO): SY7220-WO-C8 C10 -Q Applicable cable O.D. ø3.5 to ø7 Max. 10 66 58.5 47.2 32.1 42.6 [49.6] 24.5 47.6 DIN terminal (D): Pg7 24.5 47.6 (5.5) 24.5 47.6 CATALOGUE ES11-83A AVAILABLE 36 18.5 M8 124.6 139.4 M plug connector (M): 159.4 -Q 161.2 31.5 [38.5] 16.1 C8 C10 Approx. 300 (Lead wire length) SY7220-L- 79.6 L plug connector (L): (5.5) (5.5) PDF AVAILABLE ONLINE Page 49 Series SY3/5/7/9000 Body Ported Valves Dimensions: Series SY7000 3 position closed centre/exhaust centre/pressure centre 3 C8 SY7 420- G-02-Q 5 5 1/4 EA 2- ø2.2 die-cast hole P EB 1/8 (EA, EB port) 36 For manifold gasket positioning 2- ø3.2 (5.5) (For mounting) (Light/Surge voltage suppressor) 24.5 47.6 (49.5) (42.5) 31.5 [38.5] 134.4 [138.8] 60.7 [62.9] 51.5 38.5 One-touch fitting (A, B port) Applicable tubing O.D. : ø8 : ø10 13.6 G: Approx. 300 - + 16.1 Valves (66) (52) (Lead wire length) 31.5 [38.5] (P port) (A, B port) 20 2 18 0.9 (23.9) 1/4 24.5 40 3 Grommet (G): SY7 4 20- G - C10 -Q B A Manual override 19 42 2-M4 depth 6.5 (For mounting bracket) 7 20 2- ø4.2 (For manifold mounting) 24.5 47.6 Page 50 5 Max. 10 36 18.5 M8 Pg7 (5.5) 24.5 47.6 (5.5) 152.4 62.3 69.7 75.3 39.8 55.8 60.8 [63] 68.8 134.6 [139] Approx. 300 (Lead wire length) 3 SY7 420-WO-C8 C10 -Q Applicable cable O.D. ø3.5 to ø7 52.8 42.6 [49.6] M8 connector (WO): 3 SY7 420-D- C8 C10 -Q 5 66 58.5 47.2 32.1 24.5 47.6 (5.5) -Q DIN terminal (D): 79.7 3 SY7 420-M- C8 C10 5 172.4 M plug connector (M): 70.6 [72.8] 154.2 [158.6] 31.5 [38.5] 16.1 -Q Approx. 300 (Lead wire length) 5 C8 C10 80.6 3 SY7 420-L- 174.2 L plug connector (L): 24.5 47.6 (5.5) Series Base Mounted Valves Single Unit SY3/5/7/9000 Base Mounted Valve Single Unit Series ® SY3/5/7/9000 R NRTL /C Features Four available sizes Internal pilot designs Wide range of electrical connector options Locking manual overrides are possible Huge range of sub-bases and manifolds can be ordered Valves How to Order SY 5 2 40 5 Q L Series 3 5 7 9 Symbols Manual override SY3000 SY5000 SY7000 SY9000 2 position single Nil: Non-locking push type 1 2 position double Type of actuation 1 2 position single 2 2 position double 3 3 position closed centre 4 3 position exhaust centre 5 3 position pressure centre 2 D: Push-turn locking slotted type E: Push-turn locking lever type 3 position closed centre 3 3 position exhaust centre 4 Pilot type Nil R Internal pilot External pilot 3 position pressure centre 5 (Light/Surge voltage suppressor) Rated voltage DC 5 6 V S R AC ( 50 60 Hz) 1 2 3 4 24 12 6 5 3 Electrical entry for G, H, L, M, W Nil Without light/surge voltage suppressor With light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type) U VDC VDC VDC VDC VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Note: AC voltages can only be specified in conjunction with a DIN plug (Y) entry Electrical entry 24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC Grommet L plug connector M plug connector G: Lead wire LO: Without length 300 mm connector –+ Page 60 Electrical entry for D Nil Without light/surge voltage suppressor Z With light/surge voltage suppressor (Non-polar type) MO: Without connector 24, 12 VDC/ 100, 110, 200, 220 VAC24, DIN terminal (Except SY3000) D: With connector 12, 6, 5, 3 VDC M8 connector WO: Without connector cable Base Mounted Valves Single Unit Series SY3/5/7/9000 Accessories for Base Mounted SY Valves Valve type SY3*40 valves SY5*40 valves SY7*40 valves SY7*40 valves SY9*40 valves SY9*40 valves Sinlge Subbase part no. Subbase part size G 1/8 SY3000-27-1F-Q G 1/4 SY5000-27-1F-Q G 1/4 SY7000-27-1F-Q G 3/8 SY7000-27-2F-Q G 3/8 SY9000-27-1F-Q G 1/2 SY9000-27-2F-Q Electrcal connectors are common to SY body ported valves. Specifications SY3000 2 position single 2 position double 3 position Operating pressure range External pilot 2 position single Pilot Operating pressure pressure 2 position double range (MPa) range 3 position Ambient and fluid temperature (˚C) 2 position single, double Max. operating frequency (Hz) 3 position Manual override (Manual operation) Internal pilot Pilot exhaust method External pilot Lubrication Mounting orientation Enclosure Response Time SY5000 SY7000 SY9000 Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 -100 kPa to 0.7 0.25 to 0.7 0.25 to 0.7 0.25 to 0.7 -10 to 50 (No freezing) 10 5 5 5 3 3 3 3 Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type Common exhaust type for main and pilot valve Pilot valve individual exhaust Not required Unrestricted Dustproof (∗ DIN terminal, M8 connector conforms to IP65) Valves Series Fluid Internal pilot Operating pressure range (MPa) Solenoid Specifications SY3000 Response time (ms) (at the pressure of 0.5 MPa) Type of Without light/surge With light/surge voltage suppressor actuation voltage suppressor Type Z Type U 2 position single 12 or less 15 or less 12 or less 2 position double 10 or less 13 or less 10 or less 3 position 15 or less 20 or less 16 or less SY5000 Response time (ms) (at the pressure of 0.5 MPa) Type of Without light/surge With light/surge voltage suppressor actuation voltage suppressor Type Z Type U 2 position single 19 or less 26 or less 19 or less 18 or less 22 or less 18 or less 2 position double 3 position 32 or less 38 or less 32 or less SY7000 Response time (ms) (at the pressure of 0.5 MPa) Type of Without light/surge With light/surge voltage suppressor actuation voltage suppressor Type Z Type U 2 position single 31 or less 38 or less 33 or less 2 position double 27 or less 30 or less 28 or less 3 position 50 or less 56 or less 50 or less Grommet (G), (H) L plug connector: L Electrical entry M plug connector: M DIN terminal (D) (Y) M8 connector (W) DC 24, 12, 6, 5, 3 Coil rated voltage (V) 100, 110, 200, 220 ∗ AC 50 60 Hz Allowable voltage fluctuation (%) ±10% of rated voltage 0.35 (with indicator light: 0.4 DIN terminal with indicator light: 0.45) Standard Power consumption (W) DC With power saving circuit 0.1 (With indicator light only) 100 V 1.4 (With indicator light: 1.5) 110 V 1.6 (With indicator light: 1.7) 200 V 2.3 (With indicator light: 2.4) Apparent power AC 220 V 2.5 (With indicator light: 2.6) [230 V] 2.7 (With indicator light: 2.8) Surge voltage suppressor Diode (Varistor is for DIN terminal and Non-polar type.) LED (AC of DIN terminal is neon bulb.) Indicator light SY9000 Response time (ms) (at the pressure of 0.5 MPa) Type of Without light/surge With light/surge voltage suppressor actuation voltage suppressor Type Z Type U 2 position single 35 or less 41 or less 35 or less 2 position double 35 or less 41 or less 35 or less 3 position 62 or less 64 or less 62 or less CAD CD-ROM AVAILABLE CATALOGUE ES11-83A AVAILABLE PDF AVAILABLE ONLINE Page 61 Series SY3/5/7/9000 Base Mounted Valves Single Unit Type of actuation Single 2 position Double Closed centre Exhaust 3 centre position Pressure centre Type of actuation Single 2 position Double Closed centre Exhaust 3 centre position Pressure centre Series SY7000 Type of actuation Single 2 position Double Closed centre Exhaust 3 centre position Pressure centre Single 2 position Double Closed centre Exhaust 3 centre position Pressure centre Type of actuation Series SY9000 Valves Series SY5000 Series SY3000 Flow Characteristics/Weight Single 2 position Double Closed centre Exhaust 3 centre position Pressure centre Single 2 position Double Closed centre Exhaust 3 centre position Pressure centre Port size 18 Port size 14 Port size 14 38 Port size 38 12 Flow characteristics 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) Cv C (dm3/(s·bar)) b Cv C (dm3/(s·bar)) b 1.0 0.30 0.24 1.1 0.30 0.26 0.77 0.28 0.18 0.85 0.30 0.19 0.73 0.31 0.18 1.1 0.26 0.24 1.2 0.24 0.29 0.89 0.47 0.24 Flow characteristics 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) Cv C (dm3/(s·bar)) b Cv C (dm3/(s·bar)) b 2.4 0.41 0.64 2.8 0.29 0.66 1.8 0.47 0.50 1.8 0.40 0.47 1.4 0.55 0.44 3.0 0.33 0.72 3.3 0.36 0.85 1.8 0.40 0.48 Flow characteristics 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) Cv C (dm3/(s·bar)) b Cv C (dm3/(s·bar)) b 4.1 0.41 1.1 4.1 0.29 1.0 3.0 0.43 0.80 2.6 0.41 0.72 2.6 0.42 0.71 4.7 0.35 1.1 5.3 0.39 1.3 2.2 0.49 0.63 4.9 0.29 1.2 4.5 0.27 1.1 3.0 0.40 0.80 2.6 0.45 0.73 2.6 0.42 0.71 4.8 0.35 1.1 5.3 0.31 1.3 2.3 0.45 0.66 Flow characteristics 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) Cv C (dm3/(s·bar)) b Cv C (dm3/(s·bar)) b 7.9 0.34 2.0 9.6 0.43 2.6 7.5 0.33 1.8 7.3 0.30 1.7 7.2 0.34 1.7 13 0.23 2.8 12 0.26 2.8 6.7 0.40 1.9 8.0 0.48 2.2 10 0.29 2.5 7.6 0.32 1.8 7.3 0.32 1.8 7.3 0.42 2.0 13 0.32 3.6 3.3 7.4 0.33 1.9 12 0.33 Weight (g) Response W Grommet times (m/s) M8 connector 84 (50) 15 89 (57) 102 (68) 13 115 (81) 104 (69) 20 117 (82) Weight (g) Response W Grommet times (m/s) M8 connector 127 (65) 121 (58) 26 152 (89) 139 (76) 22 144 (82) 38 158 (95) Weight (g) Response W Grommet times (m/s) M8 connector 225 (96) 218 (89) 38 250 (121) 237 (108) 30 239 (110) 56 253 (124) 218 (89) 237 (108) 38 30 225 (96) 250 (121) 239 (110) 56 253 (124) Weight (g) Response W Grommet times (m/s) M8 connector 41 469(172) 476(179) 41 488(191) 502(205) 512(215) 64 526(229) 448 (151) 467 (170) 41 41 457(160) 481(184) 491 (194) 64 505(208) Note: Weights given for grommet and M8 connector. L/M connector and DIN version weights fall between these values. Response time is 0.5 MPa with Z lamp and surge option fitted. Page 62 Series Base Mounted Valves Single Unit SY3/5/7/9000 Dimensions: Series SY3000 43.5 50 7.5 24.5 16.5 1/8 (P, EA, EB port) 5 3 35 PE X B A 22 A 2- ø3.2 (For mounting) Manual override 38.1 19 17 - + Valves 19 17 11 11 20.5 41 B 53.5 [60.5] 2 position single Grommet (G): SY3140(R)- G -01-Q EA P EB M5 (Pilot EXH port) 2 G: Approx. 300 M5 (External pilot port) 44.7 66.9 [69.1] (Light/Surge voltage suppressor) (Lead wire length) 1/8 (A, B port) 13.5 14.5 M plug connector (M): M8 connector (WO): SY3140(R)-L-01-Q SY3140(R)-M-01-Q SY3140(R)-WO-01-Q 50 M8 x 1 68.5 75.9 20.5 11 11 62 67 [69.2] 20.5 11 11 16.5 24.5 16.5 24.5 Page 64 7.5 2 7.5 58 40.5 (Lead wire length) 64.6 [71.6] Approx. 300 2 2 20.5 11 11 76.8 [79] 53.5 [60.5] 38.1 Approx. 300 (Lead wire length) L plug connector (L): 7.5 16.5 24.5 Base Mounted Valves Single Unit Series SY3/5/7/9000 Dimensions: Series SY3000 35 B EB M5 44.4 88.8 [93.2] G: Approx. 300 X PE 22 - + A P - + A EA M5 (Pilot EXH port) 50 53.5 [60.5] 3 Manual override 38.1 19 17 (For mounting) 2- ø3.2 B 19 17 11 11 20.5 41 Valves 1/8 (P, EA, EB port) 7.5 16.5 24.5 2 position double Grommet (G): SY3240(R)- G -01-Q (External pilot port) (Lead wire length) (Light/Surge voltage suppressor) 14.5 1/8 13.5 (A, B port) M plug connector (M): M8 connector (WO): SY3240(R)-L-01-Q SY3240(R)-M-01-Q SY3240(R)-WO-01-Q 53.5 [60.5] 38.1 Approx. 300 (Lead wire length) L plug connector (L): 58 40.5 (Lead wire length) Approx. 300 M8 x 1 16.5 24.5 16.5 24.5 92 106.8 7.5 7.5 7.5 20.5 11 11 79 89 [93.4] 20.5 11 11 20.5 11 11 108.6 [113] 64.6 [71.6] 16.5 24.5 50 CAD CD-ROM AVAILABLE CATALOGUE ES11-83A AVAILABLE PDF AVAILABLE ONLINE Page 65 Series SY3/5/7/9000 Base Mounted Valves Single Unit Dimensions: Series SY3000 (Light/Surge voltage suppressor) 38.1 19 17 2-ø3.2 35 P EB 10.2 32.4 [34.6] 97.3 [101.7] 42.7 G: Approx. 300 X PE 22 B A - + (For mounting) B A EA M5 (Pilot EXH port) 3 3 Manual override - + Valves 19 17 11 11 20.5 41 7.5 1/8 P, EA, EB port 50 53.5 [60.5] 16.5 24.5 3 position closed centre/exhaust centre/pressure centre 3 Grommet (G): SY3 45 40(R)- G -01-Q M5 (External pilot port) (Lead wire length) 1/8 (A, B port) 13.5 14.5 L plug connector (L): M plug connector (M): M8 connector (WO): SY3 4540(R)-L-01-Q SY3 4540(R)-M-01-Q SY3 4540(R)-WO-01-Q 3 53.5 [60.5] 38.1 Approx. 300 (Lead wire length) 3 3 58 40.5 (Lead wire length) Approx. 300 M8 x 1 50 Page 66 7.5 16.5 24.5 16.5 24.5 115.3 66.5 20.5 11 11 7.5 34 41.4 16.5 24.5 27.5 32.5 [34.7] 60 97.5 [101.9] 7.5 20.5 11 11 20.5 11 11 42.3 [44.5] 117.1 [121.5] 64.6 [71.6] Base Mounted Valves Single Unit Series SY3/5/7/9000 Dimensions: Series SY5000 9.5 22 45.5 50.6 [57.6] 2 position single Grommet (G): SY5140(R)- G -02-Q 17 15.5 M5 (External pilot port) 2-ø4.3 18 28 56 1/4 P, EA, EB port (For mounting) 48 8.3 (Light/Surge voltage suppressor) 35.2 17 15.5 Valves 18 Manual override A PE X B 35 4 B - + A EA P EB M5 4.3 (Pilot EXH port) 63.7 85.9 [88.1] G: Approx. 300 (Lead wire length) 1/4 (A, B port) 9.5 18 DIN terminal (D): SY5140(R)-M-02-Q SY5140(R)-D-02-Q SY5140(R)-WO-02-Q 55.1 37.6 (Lead wire length) CAD CD-ROM AVAILABLE 9.5 22 CATALOGUE ES11-83A AVAILABLE PDF AVAILABLE ONLINE 87.5 94.9 28 18 18 104.9 105.8 18 65 4.3 22 28 18 81 86 [88.2] 9.5 M8 Pg7 4.3 4.3 28 18 18 95.8 [98] 18 28 18 4.3 22 Applicable cable O.D. ø3.5 to ø7 83.4 75.9 64.6 49.5 61.7 [68.7] Approx. 300 9.5 M8 connector (WO): Max. 10 50.6 [57.6] 35.2 Approx. 300 M plug connector (M): SY5140(R)-L-02-Q (Lead wire length) L plug connector (L): 9.5 22 Page 67 Series SY3/5/7/9000 Base Mounted Valves Single Unit Dimensions: Series SY5000 9.5 22 50.6 [57.6] 2 position double Grommet (G): SY5240(R)- G -02-Q 18 18 28 1/4 (P, EA, EB port) M5 (External pilot port) 35.2 17 15.5 2- ø4.3 48 (For mounting) 4 17 15.5 (Light/Surge voltage suppressor) Manual override 35 B A PE X - + A - + B Valves 56 EA P EB M5 62.8 107.2 [111.6] G: Approx. 300 (Pilot EXH port) (Lead wire length) 1/4 (A, B port) 9.5 18 DIN terminal (D): SY5240(R)-M-02-Q SY5240(R)-D-02-Q SY5240(R)-WO-02-Q Applicable cable O.D. ø3.5 to ø7 55.1 37.6 110.4 125.2 18 28 18 65.4 145.2 9.5 9.5 22 22 9.5 9.5 22 Page 68 M8 Pg7 147 28 18 18 18 97.4 107.4 [111.8] (Lead wire length) 61.7 [68.7]Approx. 300 M8 connector (WO): Max. 10 83.4 75.9 64.6 49.5 28 18 28 18 18 127 [131.4] 50.6 [57.6] 35.2 Approx. 300 M plug connector (M): SY5240(R)-L-02-Q (Lead wire length) L plug connector (L): 22 Base Mounted Valves Single Unit Series SY3/5/7/9000 Dimensions: Series SY5000 9.5 22 50.6 [57.6] 3 position closed centre/exhaust centre/pressure centre 3 Grommet (G): SY545 40(R)- G -02-Q 48 (For mounting) 4 4 Manual override - + A PE X A - + 35 (External pilot port) 35.2 17 15.5 1/4 (P, EA, EB port) B M5 2-ø4.3 B 17 15.5 (Light/Surge voltage suppressor) Valves 18 28 56 18 EA P EB 16 38.2 [40.4] 119.8 [124.2] 59.4 G: Approx. 300 (Lead wire length) M5 (Pilot EXH port) 1/4 (A, B port) 9.5 18 L plug connector (L): M plug connector (M): DIN terminal (D): M8 connector (WO): SY5 SY5 SY5 SY5 440(R)-WO-02-Q CAD CD-ROM AVAILABLE Max. 10 55.1 37.6 M8 22 CATALOGUE ES11-83A AVAILABLE PDF AVAILABLE ONLINE 83.2 137.8 9.5 22 39.8 47.2 157.8 60.7 17.3 9.5 57.2 22 5 Pg7 159.6 28 18 18 76.7 120 [124.4] 18 28 18 9.5 3 Applicable cable O.D. ø3.5 to ø7 (Lead wire length) 61.7 [68.7]Approx. 300 58.1 22 3 440(R)-D-02-Q 5 83.4 75.9 64.6 49.5 33.3 38.3 [40.5] 9.5 48.1 [50.3] 28 18 18 139.6 [144] 50.6 [57.6] 35.2 3 440(R)-M-02-Q 5 28 18 18 Approx. 300 (Lead wire length) 3 440(R)-L-02-Q 5 Page 69 Base Mounted Manifold Slice Type/DIN Rail Mounted Individual Wiring Series SY3/5000 Base Mounted Manifold Slice Type/DIN Rail Mounted Individual Wiring R Series SY3/5000 NRTL /C ® How to Order Manifold Series Valve stations 02 2 stations ... SY3000 SY5000 ... 3 5 20 20 stations SUP/EXH block assembly mounting position Symbol Mounting position Applicable no. of stations U U side 2 to 10 stations D D side B 2 to 20 stations (Both sides) Port size A, B port A, B port size One-touch fitting (Metric size) Symbol Port size Applicable series C4 One-touch fitting for ø4 C6 One-touch fitting for ø6 SY3000 C4 One-touch fitting for ø4 C6 One-touch fitting for ø6 SY5000 C8 One-touch fitting for ø8 Also Available Slice type manifold with individual wiring and connector box. Manifold Specifications Model Applicable valve Manifold type P (SUP)/R (EXH) Valve stations Location A, B port Porting specifications Direction P, R port Valves SS5Y 3 45 05 U C6 Q SS5Y3-45 SY340 SS5Y5-45 SY540 Stacking type/DIN rail mounted Common SUP, Common EXH 2 to 20 stations Note 1) Base Side C8 (One-touch fitting for ø8) C10 (One-touch fitting for ø10) C4 (One-touch fitting for ø4) C4 (One-touch fitting for ø4) C6 (One-touch fitting for ø6) C6 (One-touch fitting for ø6) C8 (One-touch fitting for ø8) Flow Characteristics Port size 1, 5, 3 4, 2 (P, EA, EB) (A, B) SS5Y3-45 C8 C6 SS5Y5-45 C10 C8 Model Flow characteristics 1  4/2 (P  A/B) 4/2  5/3 (A/B  EA/EB) Cv C (dm3/ (s·bar) ) b b Cv C (dm3/ (s·bar) ) 0.88 0.21 0.22 0.95 0.18 0.22 2.2 0.24 0.53 2.5 0.18 0.58 CAD CD-ROM AVAILABLE CATALOGUE E141-C AVAILABLE PDF AVAILABLE ONLINE Page 87 Base Mounted Manifold Slice Type/DIN Rail Mounted Individual Wiring SY3/5000 Series Type 45 Manifold Accessories (non-plug-in type) Individual SUP spacer assembly   Individual EXH spacer assembly Silencer with One-touch fitting  The silencer plugs directly into the One-touch fittings of the manifold. C A B End plate t Series A For SY3000 (ø8) ø16 ø22 ø25 Model Effective area 14 mm2 AN203-KM8 AN200-KM10 26 mm2 For SY5000 (ø10) 30 mm2 AN300-KM10 t  EXH port SUP port B C 26 53.8 70 51 80.8 97 L Plug (white) ød Valves These are inserted in unused cylinder ports and SUP, EXH ports. Purchasing order is available in units of 10 pieces. Assembly part no. Port size t M5 11 1 8 15 Series Assembly part no. SY3000 SY3000-39-2A-Q SY5000 SY5000-39-16FA-Q Port size t M5 11 18 15 øD Series SY3000 SY3000-38-2A-Q SY5000 SY5000-38-16FA-Q A Dimensions  Blanking plate assembly Applicable fittings size ød 4 6 8 10 Series SY3000 SY5000 L A Model KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 16 18 20.5 22 L D 32 35 39 43 6 8 10 12 Note: Interface regulators are common to type 41 and 42 manifolds. Assembly part no. SX3000-75-1A-Q SX5000-76-1A-Q DIN Rail Manifold Exploded View r Type 45 U side l n c rai utto b DINease w rel – + q – + – + w a Bolts e l n c rai utto b DINease rel b Block separation button C SM Replacement Parts No. Description Part no. SY3000 Note SY5000 SY3000 (Metric size) Manifold block q assembly w SUP/EXH block assembly e End block assembly R r End block assembly R Page 88 SX3000-50-1A--Q SX5000-50-1A--Q SX3000-51-1A SY5000 (Metric size) C4: With One-touch fitting for ø4 C6: With One-touch fitting for ø6 C4: With One-touch fitting for ø4 C6: With One-touch fitting for ø6 C8: With One-touch fitting for ø8 P, R port SY3000 (Metric size) With One-touch fitting for ø8 P, R port SY5000 (Metric size) With One-touch fitting for ø10 SX3000-51-1A SX3000-52-1A-Q SX5000-52-1A-Q SX3000-53-1A-Q SX5000-53-1A-Q For D side For U side D side Base Mounted Manifold Slice Type/DIN Rail Mounted Individual Wiring Series SY3/5000 Dimensions: Series SY3000 (Both end supplies) SS5Y3-45- Stations B- C4 C6 -Q 10.2 Approx. 300 (Lead wire length) 25.2 B B A B A B B -+ -+ 22.2 11.2 L plug connector P A R P ø4 ø6 A : 13.5 24.8 A One-touch fitting (A, B port) Applicable tubing O.D. : (Pitch) P = 10.5 24.8 R Button for DIN rail release One-touch fitting (P, R port) Applicable tubing O.D.: ø8 63.3 [70.3] 48.4 A A A A M plug connector (L4) 5 L3 L2 (Rail mounting hole pitch: 12.5) L1 97.5 [101.9] With interface regulator (with gauge) 78.3 [85.3] 42.3 74.4 [81.4] Approx. 300 (Lead wire length) (Pitch) P=10.5 13.5 24.8 A A M8 connector (WO) 33 B B B A 35 34 (64) 34.5 89 [93.4] 38 [40.2] A 15.7 33 34 88.8 [93.2] B B B B DIN rail DIN rail holding screw 8 B 97.3 [101.7] 37.9 [40.1] 37.2 28.7 35 5.5 (3) Manual override Valves 117.1 [121.5] 108.6 [113] 47.8 [50] (C6: 3.2) (Lead wire length) Approx. 300 (Light/Surge voltage suppressor) Stations n 2 stations 3 4 5 6 7 8 9 10 stations L1 110.5 123 135.5 148 160.5 173 185.5 185.5 198 L2 100 112.5 125 137.5 150 162.5 175 175 187.5 L3 97.5 108 118.5 129 139.5 150 160.5 171 87 L4 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 Stations n 11 stations 12 13 14 15 16 17 18 19 20 stations L1 210.5 223 235.5 248 248 260.5 273 285.5 298 310.5 L2 200 212.5 225 237.5 237.5 250 262.5 275 287.5 300 L3 181.5 192 202.5 213 223.5 234 244.5 255 265.5 276 L4 14.5 15.5 16.5 17.5 12 13 14 15 16 17 CAD CD-ROM AVAILABLE 80.8 106.8 115.3 ø15 39.5 77.8 100.5 92 77 90.5 M8 50.3 67.8 L1 L2 L3 L4 -12.5mm -12.5mm -16.5mm +2mm CATALOGUE E141-C AVAILABLE Note: This page shows the double supply type manifold. The U and D supply type is shorter. Apply the following corrections to to the L1 and L4 dimensions. PDF AVAILABLE ONLINE Page 89 Body Ported Manifold Cassette Type Series SY3/5/7000 A, B port size Thread piping er Valve bodies 5 LO C6F Series 3 5 7 Q 1 8 thread 1 4 thread 3 8 thread 4mm tube 6mm tube 8mm tube 10mm tube Manual override SY3000 SY5000 SY7000 2 position single solenoid Nil: Non-locking push D: Push-turn locking E: Push-turn locking slotted type type lever type 1 5 1 3 (EA) (P) (EB) Type of actuation 1 2 position single solenoid 2 2 position double solenoid 3 3 position closed centre 4 3 position exhaust centre 5 3 position pressure centre 2 position double solenoid 2 5 1 3 (EA) (P) (EB) 3 Nil Z U DC VDC VDC VDC VDC VDC 5 1 3 (EA) (P)(EB) 4 Without light/surge voltage suppressor With light/surge voltage suppressor With light/surge voltage suppressor (Non-polar type) (A) (B) 4 2 5 1 3 (EA) (P) (EB) 3 position pressure centre Electrical entry for D (SY5000/7000 only) Nil Z (A) (B) 4 2 3 position exhaust centre Electrical entry for G, H, L, M, W Rated voltage 24 12 6 5 3 (A) (B) 4 2 3 position closed centre Light/Surge voltage suppressor 5 6 V S R (A) (B) 4 2 Valves SY 3 1 60 Description SY3000 SY5000 SY7000 M5 thread Symbol M5 01F 02F 03F C4F C6F C8F C10 5 Without light/surge voltage suppressor With light/surge voltage suppressor (Non-polar type) (A) (B) 4 2 5 1 3 (EA) (P) (EB) AC (50/60Hz) 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Note: AC voltages can only be ordered in conjunction with DIN plyg (Y) electrical entry. Electrical entry 24, 12, 6, 5, 3 VDC L plug connector Grommet G: Lead wire length 300 mm LO: Without connector 24, 12 VDC/ 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC DIN terminal M8 connector M plug connector (SY5000, 7000) WO:Without connector cable Y: With connector D: With connector MO: Without connector - + Note: A manifold assembly is required to use SY cassette valves. See separate how-to-order section. ecifications ns SY3000 Series Fluid Max. operating 2 position double frequency (Hz) 3 position Pilot exhaust method Lubrication Mounting position Enclosure Grommet (G) L plug connector (L) M plug connector (M) DIN terminal (D), (Y) M8 connector (W) SY7000 Air Electrical entry 0.15 to 0.7 2 position single Internal pilot Operating pressure 2 position double range (MPa) 3 position Ambient and fluid temperature (˚C) Manual override (Manual operation) SY5000 0.1 to 0.7 0.2 to 0.7 10 5 5 3 3 3 Non-locking push type, Push-turn locking slotted type, Push-turn locking lever type Common exhaust type for main and pilot valve Not required Unrestricted Dustproof (∗ DIN terminal, M8 connector conforms to IP65) CAD CD-ROM AVAILABLE DC 24 ,12 ,6 ,5 ,3 AC 50/60Hz Allowable voltage fluctuation (%) 100 ,110 ,200 ,220∗ ±10% of rated voltage Coil rated voltage (V) Max. 50 Power consumption (W) Apparent power∗ VA DC Standard AC 0.35 [With indicator light: 0.4 (DIN terminal with indicator light: 0.45)] 100V 1.4 (With indicator light: 1.5) 110V 1.6 (With indicator light: 1.7) 200V 2.3 (With indicator light: 2.4) 220V [230V] 2.5 (With indicator light: 2.6) [2.7 (With indicator light: 2.8)] Surge voltage suppressor Diode (Varistor is for DIN terminal and non-polar) Indicator light LED (AC of DIN connector is neon bulb.) CATALOGUE ES11-83A AVAILABLE PDF AVAILABLE ONLINE Page 99 Series Body Ported Manifold SY3/5/7000 Cassette Type me SY5000 SY3000 Response time (ms) (at the pressure of 0.5 MPa) With surge voltage suppressor Without surge voltage suppressor Z type U type Type of actuation Type of actuation Response time (ms) (at the pressure of 0.5 MPa) With surge voltage suppressor Without surge voltage suppressor Z type U type 2 position single 12 or less 15 or less 12 or less 2 position single 19 or less 26 or less 19 or less 2 position double 10 or less 13 or less 10 or less 2 position double 18 or less 22 or less 18 or less 3 position 15 or less 20 or less 16 or less 3 position 32 or less 38 or less 32 or less SY7000 Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Type of actuation Z type U type 2 position single 31 or less 38 or less 33 or less 2 position double 27 or less 30 or less 28 or less 3 position 50 or less 56 or less 50 or less Note: response times as per SY base mounted valves. Valve Accessories  Individual SUP block assembly  Individual EXH block assembly (P port) R port P Plug Block disk R Block disk P ide P Ds Us Ds ide One-touch fitting (Metric size) ide Port size One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø10 One-touch fitting for ø12 Assembly part no. SY3000-54-2C SY3000-54-1C SY5000-54-1C SY7000-54-1C One-touch fitting (Metric size) Applicable series SY3000 Us ide SY5000 SY7000  Silencer with One-touch fitting Assembly part no. Port size SY3000-55-1B One-touch fitting for ø8 One-touch fitting for ø10 SY5000-55-1B One-touch fitting for ø12 SY7000-55-1B The silencer plugs directly into the One-touch fittings of the manifold. These are inserted in unused cylinder ports and SUP, EXH ports. Purchasing order is available in units of 10 pieces. ød C øD B A L Dimensions Effective area Model 14 mm2 AN203-KM8 26 mm2 AN200-KM10 SY5000 (for ø10) 30 mm2 AN300-KM10 SY7000 (for ø12) AN300-KM12 41 mm2 Series SY3000 (for ø8) A ø16 ø22 ø25 ø25 B 26 54 70 70 C 51 80.8 97 98  EXH block disk By inserting a block disc between adjacent valves, the pressure or exhaust gallery between the valves can be split into separate zones. Page 100 Applicable series SY3000 SY5000 SY7000  Plug (white) A Valves Without light/surge voltage suppressor Series Part no. SY3000 SY5000 SY7000 SY3000-52-2A SY5000-52-4A SY7000-70-2A Applicable fittings size ød 4 6 8 10 12 Model KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-12 A 16 18 20.5 22 24 L 32 35 39 43 45.5 D 6 8 10 12 14 Body Ported Manifold Cassette Type Series SY3/5/7000 Dimensions SS5Y3-60- Stations B -Q (Both ends supplies) L2 100 L3 L4 8 173 9 137.5 150 162.5 162.5 175 86 96.5 107 117.5 128 138.5 149 12 13 15 16 13 14 15 17 12 16 17 (Station 1) (Station n) One-touch fitting (P, R port) Applicable tubing O.D.: ø8 187.5 159.5 170 13 14 18 19 20 stations 285.5 298 310.5 (Light/Surge voltage suppressor) 287.5 300 201.5 212 222.5 233 243.5 254 264.5 275 17 16 11.5 14.5 12.5 13.5 16.5 15.5 17.5 - + - + - + - + - + - + Manual override (L4) L3 U side The above dimensions apply to the 'B' supply type (both ends). If the U or D type (one end) is used, please use the table below. 5 L1 98 L2 87.5 100 112.5 125 L3 69.5 80 90.5 101 L4 14 135.5 135.5 148 17 13 9 10 stations 160.5 173 185.5 B (3) A B A B A B A B A B 162.5 175 132.5 143 14 15 153.5 16 M plug connector (M) M8 connector (WO) 38.2 [45.2] 22.8 97.5 [101.9] 89 [93.4] (Lead wire length) Approx. 300 49.3 [56.3] 54.3 (Lead wire length) Approx. 300 L plug connector (L) 117.1 [121.5] 108.6 [113] 8 137.5 150 111.5 122 12 A ø6 7 M8 92 100.5 16 15 5 L1 One-touch fitting (A, B port) Applicable tubing O.D.: ø4 6 125 DIN rail DIN rail holding screw 53.4 110.5 123 8 115.3 106.8 4 D side R (Pitch) P = 10.5 13.5 24.3 L2 (Rail mounting hole pitch: 12.5) 44.5 3 R (Lead wire length) Approx. 300 33.2 (M5 port) Stations 2 stations P 4.7 P 97.3 [101.7] 88.8 [93.2] 44.4 [46.6] 30.7 22.2 22.2 10.2 M5 x 0.8 (A, B port) Valves 15 262.5 275 1 180.5 191 237.5 250 26 L3 225 212.5 225 46 200 7.5 20.7 28.2 33.4 L2 260.5 273 235.5 235.5 248 5.5 35 22.5 210.5 223 4.1 12 L1 C6:43.3 38.2 [45.2] 22.8 (3) 14 10 stations 185.5 198 112.5 125 Stations 11 stations L4 7 160.5 173 6 5 4 3 L1 110.5 123 135.5 148 (3.2) Stations 2 stations 25.2 42.7 CAD CD-ROM AVAILABLE CATALOGUE ES11-83A AVAILABLE PDF AVAILABLE ONLINE Page 101 Series Body Ported Manifold SY3/5/7000 Cassette Type SS5Y5-60- Stations B -Q (Both ends supplies) 4 5 6 7 8 stations 135.5 160.5 173 L2 125 150 162.5 175 200 212.5 225 L3 112 128 144 176 192 288 19 20 stations 360.5 385.5 398 L2 350 375 387.5 400 425 L3 336 352 368 384 400 L4 12 15 13 410.5 435.5 17.5 5.8 - + - + - + One-touch fitting g (A A,, B p port)) Applicable tubing O.D.: ø4 Manual override 1/8 (A, B port) R R (Pitch) P = 16 L3 L2 6 7 8 9 175 187.5 200 225 237.5 120 136 152 168 184 200 216 17.5 15.5 14 12 16.5 15 13 16 M plug connector (M) DIN terminal (D) MAX.10 Pg7 53.6 64.9 72.4 125.2 137.8 M8 x 1 60 147 159.6 (Lead wire length) Approx. 300 50.6 [57.6] Applicable cable O.D. ø3.5 to ø7 Page 102 M8 connector (WO) 39.6 [46.6] 24.2 60.9 [63.1] (Lead wire length) Approx. p 300 L plug connector (L) 17.5 70.9 L4 104 120 [124.4] 107.4 [111.8] 88 (L4) 5 10 stations 137.5 150 L3 28 210.5 235.5 248 70 112.5 125 5 160.5 185.5 198 20 L1 157.8 145.2 L2 4 8 (Rail mounting hole pitch: 12.5) 51.1 [53.3] 3 135.5 148 ø6 ø8 Button for DIN rail release DIN rail DIN rail holding screw The above table is for the'B' supply type (both ends). If the U or D type (one end)is used, please use the table below. 123 R - + D side 44 (1/8 port) L1 - + U side 39.6 [46.6]] Stations 2 stations - + 52.6 16.5 139.6 [144] 127 [131.4] Valves L1 R 123 110.4 18 B 17 (Lead wire length) Approx. p 300 Stations 16 stations 304 17.5 15.5 14 43.8 34.5 19.1 256 16.5 14.5 13 16 6.2 20.7 25.9 28.8 34.9 (DIN: 30.1) 320 240 (4.9) 272 12 24.2 51.9 224 L4 5.5 35 5.5 L3 (Light/Surge voltage suppressor) B 337.5 335.5 348 B 287.5 312.5 325 273 A 237.5 262.5 275 B 248 L2 A 323 L1 (Station 1) (Station n) One-touch fitting g (P,, R p port)) Applicable tubing O.D.: ø10 B 285.5 298 14 15 stations A 13 B 12 A 11 A 10 17.5 15.5 13.5 7.5 5 Stations 9 stations 208 14.5 12.5 (5.5) 11.5 16 160 119.8 [124.2] 107.2 [111.6] 51 [53.2] 46.6 (DIN: 47.9) (5.5) 34 30 (DIN: 35.3) 14.5 4.7 2.6 L4 185.5 210.5 223 235.5 P 3 L1 P Stations 2 stations 26.6 44.1