Preview only show first 10 pages with watermark. For full document please download

D2e097-ch85

   EMBED


Share

Transcript

AC centrifugal fan D2E097-CH85-02 forward curved, dual inlet with housing (without flange) ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 [email protected] www.ebmpapst.com Limited partnership · Headquarters Mulfingen County court Stuttgart · HRA 590344 General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen County court Stuttgart · HRB 590142 Nominal data Type D2E097-CH85-02 Motor M2E052-BF Phase 1~ 1~ Nominal voltage VAC 230 230 Frequency Hz 50 60 Type of data definition fa fa Valid for approval / standard CE CE Speed min-1 1550 1450 Power input W 28 32 Current draw A 0.13 0.15 Motor capacitor µF 1 1 Capacitor voltage VDB 400 400 Capacitor standard P0 (CE) P0 (CE) Min. back pressure Pa 0 0 Max. ambient temperature °C 85 80 ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit Subject to alterations Item no. 11332-5-9980 · Revision 73098 · Release 2011-01-25 · Page 1 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D2E097-CH85-02 forward curved, dual inlet with housing (without flange) Technical features Mass 1.2 kg Size 97 mm Surface of rotor Coated in black Material of impeller Sheet steel, hot-galvanised Housing material Sheet steel, hot-galvanised Direction of rotation Counter-clockwise, seen on rotor Type of protection IP 20 Insulation class "B" Max. permissible ambient motor temp. (transp./ storage) + 80 °C Min. permissible ambient motor temp. (transp./storage) - 40 °C Mounting position Shaft horizontal or rotor on bottom; rotor on top on request Condensate discharge holes Rotor-side Operation mode S1 Motor bearing Ball bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) < 0.75 mA Motor protection Thermal overload protector (TOP) wired internally Protection class I (if protective earth is connected by customer) Product conforming to standard EN 60335-1; CE Approval CCC Item no. 11332-5-9980 · Revision 73098 · Release 2011-01-25 · Page 2 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D2E097-CH85-02 forward curved, dual inlet with housing (without flange) Product drawing 1 Connection line PVC 4G 0.5 mm², 4x brass lead tips crimped Connection screen U1 blue PE green/yellow Z brown U2 black Item no. 11332-5-9980 · Revision 73098 · Release 2011-01-25 · Page 3 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D2E097-CH85-02 forward curved, dual inlet with housing (without flange) Charts: Air flow 50 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 200 0 10 20 30 40 qv[cfm] 60 50 70 80 90 100 110 120 190 0,8 0,75 180 0,7 Measurement: LU-66167 0,65 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 170 4 160 150 0,6 140 0,55 130 0,5 3 120 pf s[Pa] 100 0,4 90 p fs_E[IN H2O] 0,45 110 0,35 80 0,3 70 2 60 0,25 50 0,2 40 0,15 30 0,1 20 a] pf s[P 10 0 0,05 1 0 10 20 30 40 50 60 70 80 90 0 100 110 120 130 140 150 160 170 180 190 200 210 qv[m^3/h] Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 50 1550 28 0.13 185 0 2 230 50 1850 27 0.12 160 60 3 230 50 2230 25 0.11 125 120 4 230 50 2530 23 0.10 75 160 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 11332-5-9980 · Revision 73098 · Release 2011-01-25 · Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com AC centrifugal fan D2E097-CH85-02 forward curved, dual inlet with housing (without flange) Charts: Air flow 60 Hz Druck p f s[Pa]für Rho=1,2kg/m^3 250 0 10 20 30 40 50 qv[cfm] 60 70 80 90 100 110 240 1 0,95 230 0,9 220 0,85 210 4 200 0,8 190 0,75 180 0,7 170 0,65 160 150 p fs_E[IN H2O] pf s[Pa] 0,6 3 140 0,55 130 Measurement: LU-66168 Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 0,5 120 110 0,45 100 0,4 90 0,35 80 2 70 0,3 60 0,25 50 0,2 40 0,15 30 0,1 20 0 0,05 ] [Pa pf s 10 1 0 10 20 30 40 50 60 70 80 90 100 qv[m^3/h] 110 120 130 140 150 160 170 180 0 190 Measured values U f n Pe I qv pfs V Hz min-1 W A m3/h Pa 1 230 60 1450 32 0.15 170 0 2 230 60 1855 31 0.14 145 70 3 230 60 2390 30 0.14 110 140 4 230 60 2820 29 0.13 60 200 U = Supply voltage · f = Frequency · n = Speed · Pe = Power input · I = Current draw · qv = Air flow · pfs = Pressure increase Item no. 11332-5-9980 · Revision 73098 · Release 2011-01-25 · Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com