Preview only show first 10 pages with watermark. For full document please download

D4 32nd3-1 Spec Eng

   EMBED


Share

Transcript

2–35 Installation , Wiring, and Specifications D4–32ND3–1, 24VDC Input D4–32ND3–2 5–12VDC Input 32 (sink/source) Inputs per module 32 (sink/source) Commons per module 4 (isolated) Commons per module 4 (isolated) Input voltage range 20–28VDC Input voltage range 4.75–13.2VDC (TTL, CMOS) Peak voltage 30VDC Peak voltage 15VDC ON voltage level > 19V ON voltage level > 4 V (use pullup R for TTL in) OFF voltage level < 10 V OFF voltage level <2V Input impedance 4.8 K W Input impedance 2 KW @ 5V,1.6 KW @ 12V Input current 5 mA Input current 3.1 mA @ 5V, 7.5 mA @ 12V Minimum ON current 3.5 mA Minimum ON current 1.8 mA Maximum OFF current 1.6 mA Maximum OFF current 0.8 mA Base power required 5V 150 mA max Base power required 5V 150 mA max OFF to ON response 2–10 ms OFF to ON response 1–4 ms ON to OFF response 2–10 ms ON to OFF response 1–4 ms Terminal type Removable, 40 pin conn. Terminal type Removable, 40 pin conn. Status indicators Logic Side Status indicators Logic Side Weight 6.6 oz. (190 g) Weight 6.6 oz. (190 g) Derating Chart Points 32 28 24 20 16 12 8 4 0 24VDC INPUT A-B C-D B/D A/C 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 D4–32ND3–1 0 10 20 30 40 50 60° C 32 50 68 86 104 122 140° F Ambient Temperature (°C/°F) Current Flow User Supply – Current Flow – User Supply + Current Flow + User Supply – Current Flow B0 B4 B1 B5 B2 B6 B3 B7 COM II C0 C4 C1 C5 C2 C6 C3 C7 COM III D0 D4 D1 D5 D2 D6 D3 D7 COM IV 24 VDC Common + – A-B 0 10 20 30 40 50 60° C 32 50 68 86 104 122 140° F Ambient Temperature (°C/°F) 20–28VDC, CLASS2 4.2–5.8mA Current Flow + User Supply – Current Flow – User Supply + Current Flow + User Supply – Current Flow 5–12 VDC + – 0 1 2 3 4 5 6 7 A0 A4 A1 A5 A2 A6 A3 A7 COM I DISPLAY SELECT A-B C-D 4.75–13.2VDC, CLASS2 3.1–8.2mA A0 A4 A1 A5 A2 A6 A3 A7 CI CI B0 B4 B1 B5 B2 B6 B3 B7 CII CII C0 C4 C1 C5 C2 C6 C3 C7 CIII CIII D0 D4 D1 D5 D2 D6 D3 D7 CIV CIV B0 B4 B1 B5 B2 B6 B3 B7 COM II C0 C4 C1 C5 C2 C6 C3 C7 COM III D0 D4 D1 D5 D2 D6 D3 D7 COM IV Common To LED Use Display Select switch to view Optical(A0–A7, B0–B7) or (C0–C7, D0–D7) Isolator 4 5 6 7 D4–32ND3–2 To LED Input INPUT A-B C-D B/D A/C 0 1 2 3 C-D A0 A4 A1 A5 A2 A6 A3 A7 CI CI B0 B4 B1 B5 B2 B6 B3 B7 CII CII C0 C4 C1 C5 C2 C6 C3 C7 CIII CIII D0 D4 D1 D5 D2 D6 D3 D7 CIV CIV 5–12VDC Current sinking config. shown Input Use Display Select switch to view B0–B7) or (C0–C7, D0–D7) Current sinking config. shown Optical (A0–A7, Isolator DL405 User Manual, 3rd Edition, Rev. E Installation and Safety Guidelines + A0 A4 A1 A5 A2 A6 A3 A7 COM I DISPLAY SELECT Derating Chart Points 32 28 24 20 16 12 8 4 0 Installation, Wiring, and Specifications Inputs per module