HEIM DATaRec® MDR series Technical Specifications Signal Modules
General Signal rate per channel
(R)NRZ-L, -M, -S code: 1 kbit/s to 30 Mbit/s BiPhase-L,-M,S code: 10 kbit/s to 10 Mbit/s
®
The HEIM DATaRec 4 MDR MAMU module is an input module for ARINC 429, MIL –STD- 1558B and PCM data. The module can be integrated in a MDR mainframe and combined with any other HEIM DATaRec® 4 MDR modules to a multi-channel recording system. The MAMU module supports 2 dual –redundant MIL-STD-1553B input channels, 2 PCM input channels and 8 ARINC 429 input channels. The module is available in the following configuration: HS510-3040 transformer coupled MIL bus version, throughput mode PCM data 100 Ω input impedance HS510-3040/1 direct coupled MIL bus version, throughput mode PCM data 100 Ω input impedance HS510-3040/2 transformer coupled MIL bus version, packed, unpacked and throughput mode PCM data 75 Ω input impedance Other versions on request
Clock source
external or internal
Clock rate
Internal: fixed clock rate in steps selectable. Possible steps: 120MHz/x (4 <= x <= 120000) External: the receiver synchronizes automatically to the incoming bit rate
Clock edge
rising or falling edge selectable
Symmetrical standards
RS422 or RS485 1 Kbit/s – 1 Mbit/s: ± 250mV 1 Mbit/s – 5 Mbit/s: ± 300mV 5 Mbit/s – 10 Mbit/s: ± 400mV 10 Mbit/s – 20 Mbit/s: ± 500mV 20 Mbit/s – 30 Mbit/s: ± 600mV
Symmetrical threshold level
Single ended standard
MAMU (HS510-3340) MAMUa (HS510-3340) MAMUd (HS510-3340/1)
PCM/ARR/UAR hybrid input module PCM input Application mode PCM mode
Record (no E to E mode) Throughput with frame synch detection (only HS5103040/2)packed 16 or 32 bit with Intra-packet time stamp (only HS510-3040/2) unpacked 16 or 32 bit with Intra-packet time stamp (only HS510-3040/2)
Input signal
2 independent PCM input streams
Input format
NRZ or BiPhase PCM code
Max. module data rate
100 Mbit/s
ZODIAC Data Systems GmbH
TTL
Default TTL threshold level
1.4 V
Single ended threshold level
in 0.1 V steps from 0 V to 3.3 V selectable
Maximum input voltage Input impedance (per channel configurable)
-7 V to 12 V low-Z or high-Z low-Z is 100 Ω (HS510-3040 and HS510-3040/1) low-Z is 75 Ω (HS510-3040/2) high-Z is 22 kΩ
Time stamping resolution:
100 ns
Status indicators PCM data Error bits (reported by the .HEALTH) Self test error No input data Wrong clock edge selected Bad/unstable input clock Page 1 of 3
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.
Document No.: TI_MAMU_EN_01_11_12_HD5611041010.doc
HEIM DATaRec® MDR series Technical Specifications Signal Modules External clock timeout No minor frame lock No major frame lock No watch word detected Additional information bits Measured bitrate PRBS15 pattern detected 1x1+14x0 bit pattern detected Synch detected Number of synch drops and synch locks since last interval Minor locked Major locked Watch word detected
Replay Replay with UAP100
ARINC 429 input channels
Functions Integrated test pattern recognition PRBS15 and W15 function For module inspection
Application mode
record, no E to E
Number of channels
8 high speed or low speed busses
Input signal
ARINC 429
Signal level Operation mode
ARINC 429 standard bus monitor only bus test functions
Total bus recording
yes
Selected bus recording
yes
Bus speed identification
automatic bus load computed and displayed
Bus load identification
Replay PCM data Replay is possible with MRG100
record, no E to E, bus monitor only
Operation mode
tolerant: noise and/or bad data between two valid MIL-STD-1553 messages will be ignored
2 independent dual-redundant MILSTD-1553B busses
Transformer coupled
HS510-3040 and HS510-3040/2
Time resolution
100 ns
Replay with ARP100
Status indicators
strict: Accurate MIL-STD-1553 bus analysis Input signal
time stamps for all messages, exact response time recording
Replay
MIL STD 1553 input channels Application mode
Time stamping
Error bits (reported by the HEALTH) Self test error Format error Information bits Bus load and speed display
Signal level
0.86 Vpp - 14 Vpp
Direct coupled
HS510-3040/1
Signal level
1.15 Vpp - 20 Vpp
Total bus recording
yes
Selected bus recording
yes
Max. module data rate
100 Mbit/s
Selected message recording
no
Supported data format
Time stamping resolution
100 ns
each channel provides an Independent IRIG 106 chapter 10 data stream
Power consumption
3 W typical, max. 4 W
Connector
connector 37 pins 10 pins for MRG channels 17 pins for ARINC channels 9 pins for UAR channels 1 pin error testpoint
Dimensions
110*18*110.8 mm (w*h*d)
Weight
220 g typical
General information
Status indicators Error bits (reported by the .HEALTH) Self test error Response time out Format error Invalid word Word count error Additional information bits Dual-redundant bus load display. Separated for bus a and bus b ZODIAC Data Systems GmbH
Page 2 of 3
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.
Document No.: TI_MAMU_EN_01_11_12_HD5611041010.doc
HEIM DATaRec® MDR series Technical Specifications Signal Modules Environmentalspecifications MAMU Temperature (operational)
Vibration
MIL-STD-810F
Method 514
Category 24, general use, scaled to 10grms
MIL-STD-810F
Method 501
Procedure II, +71°C
Shock (operational)
Method 502
Procedure II, -40°C
Method 516
MIL-STD-810F Procedure I, 20g 11ms
Temperature (storage)
MIL-STD-810F
Shock (crash safety)
MIL-STD-810F
Method 501
Procedure I, +85°C
Method 516
Procedure V, 40g 11ms
Procedure I, -50°C
Acceleration
MIL-STD810F
Humidity
MIL-STD-810F
Method 513
20g
Method 507
95% rel. h., non-condensing
Method 502
Altitude
MIL-STD-810F
Method 500
Procedure II, 21.000m
RFI Method CE101
MIL-STD-461F Class: Army Aircraft, 28V or below
Method CE102
Class: 28V
Method CS101
Class: 28V or below
Method CS114
Class: Aircraft External
Notes Performance varies depending on the installation environment. The storage media type used significantly can influence the recording results. For more information please contact Zodiac Data Systems GmbH.
Method CS115 Method CS116 Method RE101
Class: Navy Applications
Method RE102
Class: Aircraft, Fixed Wing Internal <25m
Method RS101
Class: Army Applications
Method RS103
Class: Aircraft External
Application The Heim DATaRec® MDR series supports a wide range of applications. The modular system fulfils the challenges of the ‘Classic FTI’ as well as the requirements in the Serial FTI. Mission application such as video recording and debriefing tasks can be realized with the MDR family. The compact MDR2 is an ideal platform for HUMS- and service application where fast and efficient fault finding becomes an issue.
ZODIAC Data Systems GmbH Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99
[email protected] – http://www.zodiac-data-systems.com ZODIAC Data Systems GmbH
Page 3 of 3
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.
Document No.: TI_MAMU_EN_01_11_12_HD5611041010.doc