HEIM DATaRec® MDR series Technical Specifications Signal Modules General Signal rate per channel (R)NRZ-L, -M, -S code: 1 kbit/s to 30 Mbit/s BiPhase-L,-M,S code: 10 kbit/s to 10 Mbit/s ® The HEIM DATaRec 4 MDR MAMU module is an input module for ARINC 429, MIL –STD- 1558B and PCM data. The module can be integrated in a MDR mainframe and combined with any other HEIM DATaRec® 4 MDR modules to a multi-channel recording system. The MAMU module supports 2 dual –redundant MIL-STD-1553B input channels, 2 PCM input channels and 8 ARINC 429 input channels. The module is available in the following configuration: HS510-3040 transformer coupled MIL bus version, throughput mode PCM data 100 Ω input impedance HS510-3040/1 direct coupled MIL bus version, throughput mode PCM data 100 Ω input impedance HS510-3040/2 transformer coupled MIL bus version, packed, unpacked and throughput mode PCM data 75 Ω input impedance Other versions on request Clock source external or internal Clock rate Internal: fixed clock rate in steps selectable. Possible steps: 120MHz/x (4 <= x <= 120000) External: the receiver synchronizes automatically to the incoming bit rate Clock edge rising or falling edge selectable Symmetrical standards RS422 or RS485 1 Kbit/s – 1 Mbit/s: ± 250mV 1 Mbit/s – 5 Mbit/s: ± 300mV 5 Mbit/s – 10 Mbit/s: ± 400mV 10 Mbit/s – 20 Mbit/s: ± 500mV 20 Mbit/s – 30 Mbit/s: ± 600mV Symmetrical threshold level Single ended standard MAMU (HS510-3340) MAMUa (HS510-3340) MAMUd (HS510-3340/1) PCM/ARR/UAR hybrid input module PCM input Application mode PCM mode Record (no E to E mode) Throughput with frame synch detection (only HS5103040/2)packed 16 or 32 bit with Intra-packet time stamp (only HS510-3040/2) unpacked 16 or 32 bit with Intra-packet time stamp (only HS510-3040/2) Input signal 2 independent PCM input streams Input format NRZ or BiPhase PCM code Max. module data rate 100 Mbit/s ZODIAC Data Systems GmbH TTL Default TTL threshold level 1.4 V Single ended threshold level in 0.1 V steps from 0 V to 3.3 V selectable Maximum input voltage Input impedance (per channel configurable) -7 V to 12 V low-Z or high-Z low-Z is 100 Ω (HS510-3040 and HS510-3040/1) low-Z is 75 Ω (HS510-3040/2) high-Z is 22 kΩ Time stamping resolution: 100 ns Status indicators PCM data Error bits (reported by the .HEALTH) Self test error No input data Wrong clock edge selected Bad/unstable input clock Page 1 of 3 All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. Document No.: TI_MAMU_EN_01_11_12_HD5611041010.doc HEIM DATaRec® MDR series Technical Specifications Signal Modules External clock timeout No minor frame lock No major frame lock No watch word detected Additional information bits Measured bitrate PRBS15 pattern detected 1x1+14x0 bit pattern detected Synch detected Number of synch drops and synch locks since last interval Minor locked Major locked Watch word detected Replay Replay with UAP100 ARINC 429 input channels Functions Integrated test pattern recognition PRBS15 and W15 function For module inspection Application mode record, no E to E Number of channels 8 high speed or low speed busses Input signal ARINC 429 Signal level Operation mode ARINC 429 standard bus monitor only bus test functions Total bus recording yes Selected bus recording yes Bus speed identification automatic bus load computed and displayed Bus load identification Replay PCM data Replay is possible with MRG100 record, no E to E, bus monitor only Operation mode tolerant: noise and/or bad data between two valid MIL-STD-1553 messages will be ignored 2 independent dual-redundant MILSTD-1553B busses Transformer coupled HS510-3040 and HS510-3040/2 Time resolution 100 ns Replay with ARP100 Status indicators strict: Accurate MIL-STD-1553 bus analysis Input signal time stamps for all messages, exact response time recording Replay MIL STD 1553 input channels Application mode Time stamping Error bits (reported by the HEALTH) Self test error Format error Information bits Bus load and speed display Signal level 0.86 Vpp - 14 Vpp Direct coupled HS510-3040/1 Signal level 1.15 Vpp - 20 Vpp Total bus recording yes Selected bus recording yes Max. module data rate 100 Mbit/s Selected message recording no Supported data format Time stamping resolution 100 ns each channel provides an Independent IRIG 106 chapter 10 data stream Power consumption 3 W typical, max. 4 W Connector connector 37 pins 10 pins for MRG channels 17 pins for ARINC channels 9 pins for UAR channels 1 pin error testpoint Dimensions 110*18*110.8 mm (w*h*d) Weight 220 g typical General information Status indicators Error bits (reported by the .HEALTH) Self test error Response time out Format error Invalid word Word count error Additional information bits Dual-redundant bus load display. Separated for bus a and bus b ZODIAC Data Systems GmbH Page 2 of 3 All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. Document No.: TI_MAMU_EN_01_11_12_HD5611041010.doc HEIM DATaRec® MDR series Technical Specifications Signal Modules Environmentalspecifications MAMU Temperature (operational) Vibration MIL-STD-810F Method 514 Category 24, general use, scaled to 10grms MIL-STD-810F Method 501 Procedure II, +71°C Shock (operational) Method 502 Procedure II, -40°C Method 516 MIL-STD-810F Procedure I, 20g 11ms Temperature (storage) MIL-STD-810F Shock (crash safety) MIL-STD-810F Method 501 Procedure I, +85°C Method 516 Procedure V, 40g 11ms Procedure I, -50°C Acceleration MIL-STD810F Humidity MIL-STD-810F Method 513 20g Method 507 95% rel. h., non-condensing Method 502 Altitude MIL-STD-810F Method 500 Procedure II, 21.000m RFI Method CE101 MIL-STD-461F Class: Army Aircraft, 28V or below Method CE102 Class: 28V Method CS101 Class: 28V or below Method CS114 Class: Aircraft External Notes Performance varies depending on the installation environment. The storage media type used significantly can influence the recording results. For more information please contact Zodiac Data Systems GmbH. Method CS115 Method CS116 Method RE101 Class: Navy Applications Method RE102 Class: Aircraft, Fixed Wing Internal <25m Method RS101 Class: Army Applications Method RS103 Class: Aircraft External Application The Heim DATaRec® MDR series supports a wide range of applications. The modular system fulfils the challenges of the ‘Classic FTI’ as well as the requirements in the Serial FTI. Mission application such as video recording and debriefing tasks can be realized with the MDR family. The compact MDR2 is an ideal platform for HUMS- and service application where fast and efficient fault finding becomes an issue. ZODIAC Data Systems GmbH Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99 [email protected] – http://www.zodiac-data-systems.com ZODIAC Data Systems GmbH Page 3 of 3 All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. Document No.: TI_MAMU_EN_01_11_12_HD5611041010.doc