Transcript
Conettix D6600/D6100i
Computer Interface Manual
EN
Receiver/Gateway
Conettix D6600/D6100i | Computer Interface Manual | Trademarks
Trademarks Microsoft®, Windows®, Windows NT® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
2
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | Contents .
Contents 1.1 1.2 2.0 2.1 2.2 3.0 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.1.7 3.1.8 3.1.9 3.1.10 3.1.11 3.1.12 3.1.13 3.1.14 3.1.15 3.1.16 3.1.17 3.1.18 3.1.19 3.1.20 3.1.21 3.1.22 3.1.23 3.1.24 3.1.25 3.1.26 3.1.27 3.1.28 3.1.29 3.1.30 3.1.31 3.2
Conettix D6680 Ethernet Network Adapter Connection..........................................................7 Direct Connection – RS-232 .............................7 Making the Right Connection.......................8 COM3 DB9 Connector .....................................8 Selecting Program Options in the D6600/D6100i ....................................................8 Computer Communication Protocols..........9 D6500 Mode Messages......................................9 Acron Super Fast (Message Type 9).................9 Ademco 4-1 Express (Message Type b).........10 Ademco 4-2 Express (Message Type c) .........10 Ademco Contact-ID (Message Type a)..........11 Ademco High Speed, 4-8-1 (Message Type f) ..............................................11 ADT SIA (Message Type S)............................12 Caller ID (Message Type e) ............................12 CFSK (Message Type i) ...................................13 Common Formats (Message Type 1) .............13 DNIS/ANI (Message Type N) ........................14 DSC 4-3 (Message Type d)..............................14 FBI Super Fast (Message Type F) ...................15 ITI (Message Type I) .......................................15 Link Test (Message Type 1) ............................15 Robofon (Message Type j)...............................16 Sescoa Super Speed (Message Type 7) ..........17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ....................18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)....................19 Seriee FSK (Message Type k) .........................20 Seriee DTMF (Message Type l) ......................20 SIA (Message Type S)......................................21 Silent Knight FSK0 (Message Type 1) ...........22 Silent Knight FSK2 (Message Type m) ..........24 Silent Knight FSK80 D6500 mode (Message Type E) .............................................24 Telim (Message Type n) ..................................25 Text Message (Message Type 3) .....................25 Varitech FSK 4-1 (Message Type 1)...............26 Varitech FSK 4-2 (Message Type 1)...............26 VONK (Message Type V)...............................27 X-SIA Text (Message Type S) ........................27 SafeCom (Message Type p).............................28 SIA Mode Messages.........................................28
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
3.2.1 3.2.2 3.2.3 3.2.4 3.2.5
Acron Super Fast (Message Type 9) .............. 28 Ademco Contact-ID (Message Type a) ......... 29 Ademco 4-1 Express (Message Type b) ........ 30 Ademco 4-2 Express (Message Type c)......... 31 Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) .................................... 32 3.2.6 ADT SIA (Message Type
) ................ 33 3.2.7 Caller ID (Message Type ) ................ 33 3.2.8 CFSK (Message Type I) .................................. 34 3.2.9 Common Formats (Message Type ) . 34 3.2.10 DNIS/ANI (Message Type N)........................ 35 3.2.11 DSC 4-3 (Message Type d) ............................. 36 3.2.12 FBI Super Fast (Message Type F) .................. 37 3.2.13 ITI (Message Type I)....................................... 38 3.2.14 Link Test (Message Type ) ................ 38 3.2.15 RB2000 (Message Type R) Description ........ 39 3.2.16 Robofon (Message Type j) .............................. 40 3.2.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ................... 40 3.2.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) ................... 41 3.2.19 Seriee DTMF (Message Type l)...................... 42 3.2.20 Seriee FSK (Message Type k) ......................... 42 3.2.21 Sescoa Super Speed (Message Type 7).......... 43 3.2.22 Silent Knight FSK() (Message Type ) ............................................................ 44 3.2.23 Silent Knight FSK1 (Message Type m).......... 44 3.2.24 Silent Knight FSK2 (Message Type m).......... 46 3.2.25 Silent Knight FSK80 (Message Type E) ........ 47 3.2.26 Telim (Message Type n).................................. 48 3.2.27 Varitech FSK 4-1 (Message Type ).. 48 3.2.28 Varitech FSK 4-2 (Message Type )... 49 3.2.29 VONK (Message Type V) .............................. 49 3.2.30 X-SIA text (Message Type ) .............. 50 3.2.31 SafeCom (Message Type p) ............................ 51 3.3 Input Command Processing ........................... 52 Appendix A: Contact ID Event Code Classifications................................................. 53 Appendix B: Internal Messages................................ 58 Appendix C: Modem IIIa2 Messages ....................... 61 C.1 Zonex and Comex Translation .................... 137 Appendix D: Network Messages............................ 138 Appendix E: Pulse Output ....................................... 141 Appendix F: Format ID (by Message Type) – D6600 Only .................................................. 146
3
Conettix D6600/D6100i | Computer Interface Manual | Contents Appendix G: ADT SIA Report Codes ...................149 Appendix H: RB2000 Messages (D6600 Only) .....151 Appendix I: SafeCom Messages (D6600 Only) ....158
Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Figure 15: Figure 16: Figure 17: Figure 18: Figure 19: Figure 20: Figure 21: Figure 22: Figure 23: Figure 24: Figure 25: Figure 26:
Table 8: Table 9:
Figures Figure 1:
Table 7:
D6600/D6100i System – Standard/Network Automation .................7 D6600 System – Direct Connect ...............7 D6100i System – Direct Connect ..............7 Null Modem Cable Configuration ............8 Straight-through Modem Cable Configuration...............................................8 Modem Cable Pin Definitions ...................8 Message sent to printer.............................28 Message sent to printer.............................29 Message sent to printer.............................30 Message sent to printer.............................31 Message sent to printer.............................32 Message sent to Printer.............................33 Message sent to printer.............................34 Message sent to printer.............................35 Message sent to printer.............................35 Message sent to printer.............................36 Message sent to printer.............................37 Single message sent to Printer..................39 Multiple messages sent to printer ............39 Message sent to printer.............................41 Message sent to printer.............................41 Message sent to printer.............................43 Message sent to printer.............................47 Message sent to printer.............................50 Contact ID format.....................................53 D6200 Receiver Software Line Card Configuration...........................................141
Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Table 16: Table 17: Table 18: Table 19:
Table 20:
Table 21: Table 22: Table 23: Table 24: Table 25:
Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6:
4
Recommended Programming Selections..8 D6600 Line Number/Group Number Conversion Table........................................9 Message Type 9 (Acron Super Fast) Byte Description...................................................9 Message Type b (Ademco 4-1 Express) Byte Description........................................10 Message Type c (Ademco 4-2 Express) Byte Description........................................10 Message Type a (Ademco Contact ID) Byte Description........................................11
Table 26: Table 27: Table 28: Table 29: Table 30: Table 31:
Message Type f (Ademco High Speed, 4-8-1) Byte Description ............................ 11 ADT SIA (Message Type S) Byte Description ................................................ 12 Caller ID (Message Type e) Byte Description ................................................ 12 CFSK (Message Type i) Byte Description ................................................ 13 Common Formats (Message Type 1) Byte Description ................................................ 13 DNIS/ANI (Message Type N) Byte Description ................................................ 14 DSC-4-3 (Message Type d) Byte Description ................................................ 14 FBI Super Fast (Message Type F) Byte Description ................................................ 15 ITI (Message Type I) Byte Description .. 15 Link Test (Message Type 1) Byte Description ................................................ 16 Robofon (Message Type j) Byte Description ................................................ 16 Sescoa Super Speed (Message Type 7) Byte Description ....................................... 17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description ................................................ 18 Scancom 4-24-1, 5-24-1, 6-24-1 Available Upon Request (Message Type h) Byte Description......................... 19 Seriee FSK (Message Type k) Byte Description ................................................ 20 Seriee DTMF (Message Type l) Byte Description ................................................ 20 SIA (Message Type S) Byte Description ................................................ 21 SIA (Message Type S) Byte Description ................................................ 21 Silent Knight FSK1 (Message Type m) Byte Description ....................................... 22 Optional Silent Knight SK1 (Message Type m) Byte Description........................ 22 Silent Knight Automation Format........... 23 Silent Knight FSK2 (Message Type m) Byte Description ....................................... 24 Silent Knight FSK80 (Message Type E) Byte Description ....................................... 24 Telim (Message Type n) Byte Description ................................................ 25 Text Message (Message Type 3) Byte Description ................................................ 25
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | Contents . Table 32:
Varitech FSK 4-1 (Message Type 1) Byte Description........................................26 Table 33: Varitech FSK 4-2 (Message Type 1) Byte Description........................................26 Table 34: VONK (Message Type V) Byte Description.................................................27 Table 35: X-SIA Text (Message Type S) Byte Description.................................................27 Table 36: SafeCom (Message Type p) Byte Description.................................................28 Table 37: Acron Super Fast (Message Type 9) Byte Description.................................................28 Table 38: Acron Super Fast (Message Type 9) Printer Output ...........................................28 Table 39: Ademco Contact-ID (Message Type a) Byte Description........................................29 Table 40: Ademco Contact-ID (Message Type a) Printer Output ...........................................29 Table 41: Ademco 4-1 Express (Message Type b) Byte Description........................................30 Table 42: Ademco 4-1 Express (Message Type b) Printer Output ...........................................30 Table 43: Ademco 4-2 Express (Message Type c) Byte Description........................................31 Table 44: Ademco 4-2 Express (Message Type c) Printer Output ...........................................31 Table 45: Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description........................................32 Table 46: Ademco High Speed, 4-8-1 (Message Type f) Printer Output..............................32 Table 47: ADT SIA (Message Type ) Byte Description.................................................33 Table 48: Caller ID (Message Type ) Byte Description.................................................33 Table 49: CFSK (Message Type I) Byte Description.................................................34 Table 50: Common Formats (Message Type ) Byte Description ........................34 Table 51: Common Formats (Message Type ) Byte Description ........................35 Table 52: DNIS/ANI (Message Type N) Byte Description.................................................35 Table 53: DSC 4-3 (Message Type d) Byte Description.................................................36 Table 54: DSC 4-3 (Message Type d) Printer Output ........................................................36 Table 55: Event Code Table .....................................36 Table 56: Printer Output Codes ...............................36
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Table 57: Table 58: Table 59: Table 60: Table 61: Table 62: Table 63: Table 64: Table 65: Table 66:
Table 67:
Table 68:
Table 69:
Table 70: Table 71: Table 72: Table 73: Table 74: Table 75: Table 76: Table 77: Table 78: Table 79: Table 80: Table 81:
FBI Super Fast (Message Type F) Byte Description ................................................ 37 FBI Super Fast (Message Type F) Printer Output........................................... 37 Event Code Table..................................... 37 Printer Output Codes ............................... 37 ITI (Message Type I) Byte Description .. 38 Link Test (Message Type ) Description ................................................ 38 RB2000 (Message Type R) Byte Description ................................................ 39 RB2000 (Message Type R) Printer Output........................................................ 39 Robofon (Message Type j) Byte Description ................................................ 40 Scancom 4-16-1, 5-16-1, 6-16-1 Available Upon Request (Message Type g) Byte Description ......................... 40 Scancom 4-16-1, 5-16-1, 6-16-1 Available Upon Request (Message Type g) Printer Output............................. 41 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description ................................................ 41 Scancom 4-24-1, 5-24-1, 6-24-1 Available Upon Request (Message Type h) Printer Output ............................ 41 Seriee DTMF (Message Type l) Byte Description ................................................ 42 Seriee FSK (Message Type k) Byte Description ................................................ 42 Sescoa Super Speed (Message Type 7) Byte Description ....................................... 43 Sescoa Super Speed (Message Type 7) Printer Output........................................... 43 Silent Knight FSK0 (Message Type ) Byte Description........................ 44 Silent Knight FSK1 (Message Type m) Byte Description ....................................... 44 Optional Silent Knight FSK1 (Message Type m) Byte Description........................ 45 Silent Knight FSK1 Optional Outputs.... 45 Silent Knight FSK2 (Message Type m) Byte Description ....................................... 46 Silent Knight FSK80 (Message Type E) Byte Description ....................................... 47 Silent Knight FSK80 Printer/LCD output .................................................................... 47 Telim (Message Type n) Byte Description .................................................................... 48
5
Conettix D6600/D6100i | Computer Interface Manual | Contents Table 82: Table 83: Table 84: Table 85: Table 86: Table 87: Table 88: Table 89: Table 90: Table 91: Table 92: Table 93: Table 94: Table 95: Table 96: Table 97: Table 98: Table 99: Table 100: Table 101: Table 102: Table 103: Table 104: Table 105: Table 106: Table 107: Table 108: Table 109: Table 110: Table 111: Table 112: Table 113: Table 114: Table 115: Table 116:
6
Varitech FSK 4-1 (Message Type ) Byte Description ........................48 Varitech FSK 4-2 (Message Type ) Byte Description ........................49 VONK (Message Type V) Byte Description.................................................49 X-SIA text (Message Type ) Byte Description........................................50 X-SIA Printer/LCD output ......................50 SafeCom (Message Type p) Byte Description.................................................51 ASCII Text Message to Automation Port .............................................................52 Input Command Output Messages .........52 Event Codes...............................................53 Internal Messages......................................58 Modem IIIa2 Messages .............................61 Point to Zonex Translation ....................137 User ID to Comex Translation ..............137 Reported Zone/ID to Actual Point/ID ...................................................137 Network Messages...................................138 Pulse 3/1 Format .....................................141 Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 1..............................142 Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 2..............................142 Pulse 3/2...................................................143 Pulse 4/1...................................................143 Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1 ...........................................144 Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2 ...........................................144 Pulse 4/2...................................................145 Pulse 4/3...................................................145 Generic Byte Description .......................146 Generic SIA Byte Description ...............146 Message Examples ..................................147 ADT SIA Report Codes .........................149 RB2000 Messages....................................151 Virtual Line Conversion Table..............158 SafeCom Messages - Line Card or Account Signals .......................................159 SafeCom Messages - Intercepted Control Panel Signals..............................162 Explanation of Automation Output Items (within Message Body only) ........164 Explanation of Printer Output Items.....165 Supported Event Codes..........................166
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 1.0
System Connection
.
1.0 System Connection 1.1
Conettix D6680 Ethernet Network Adapter Connection
Use the Conettix D6680 Ethernet Network Adapter to connect a manufacturer’s automation software package to the D6600 when the software cannot receive network data (Figure 1). Refer to the Special Conettix D6600 Applications in the Conettix D6600/D6100i Network System Guide (P/N: 4998122712). Figure 1:
1.2
Direct Connection – RS-232
Figure 2 and Figure 3 show a D6600/D6100i System using any manufacturer’s automation software package directly connected to a D6600 or D6100i. Figure 2:
D6600 System – Direct Connect
D6600/D6100i System – Standard/Network Automation
1 - Automation PC 2 - Connection - Automation PC COM port to D6600 COM3 3 - D6600 Figure 3:
12345678910 11 *
Automation PC Connection - PC COM1 to D6680 D6680 Connection - D6680 to hub Hub Connection – D6100i to hub D6100i Connection – D6680 to hub Second D6680 Connection - D6680 to D6600 COM4 D6600
D6100i System – Direct Connect
1 - Automation PC 2 - Connection - Automation PC COM port to D6100i COM3 3 - D6100i
For automation packages with network capabilities: The packet format received from the D6600 is the same as for RS-232 reporting, execpt an internet protocol (IP) and user datagram protocol (UDP) header is stamped on the packet as the data transmitted by either standard IP or UDP structure over the network. Automation software can support the network communication easily by calling Socket functions, both provided in Windows and Unix. by using the built-in IP connections (or sockets) available in Windows and Unix.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
7
Conettix D6600/D6100i | Computer Interface Manual | 2.0
Making the Right Connection Each pin of the modem cable is defined in Figure 6.
2.0 Making the Right Connection 2.1
Figure 6:
COM3 DB9 Connector
1
The COM3 Port uses a standard DB9 female connector. The suggested connections to the computer are shown in Figure 4 to Figure 6. When connecting data terminal equipment (DTE) together (such as a COM1 port to PC serial port), a null-modem cable must be used. One possible configuration for a null-modem cable is shown in Figure 4. Figure 4:
Null Modem Cable Configuration DTE DB-9 Pin
DTE DB-9 Pin
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
When connecting data terminal equipment to data communication equipment (DCE) (such as the D6600/D6100i COM port to a modem), a modem cable should be used (such as a straight-through cable shown in Figure 5). Figure 5:
8
DCE
1
8
2
3
3
2
4
20
5
7
6
6
7
4
8
5
9
22
2 6
1 - Data carrier detect (DCD) 2 - Receive (RX) 3 - Transmit (TX) 4 - Data terminal ready (DTR) 5 - Signal-ground (SIG-GND)
2.2
3 7
4 8
5 9
6 - Data set ready (DSR) 7 - Ready to send (RTS) 8 - Clear to send (CTS) 9 - Ring indicator (RI)
Selecting Program Options in the D6600/D6100i
Use the D6600/D6100i keypad or the D6200 Programming Software to program the receivers. Below are the recommended selections for programming when connecting the receivers to an automation system. Additional selections can be found in the D6600/D6100i Program Entry Guide (P/N: 4998122702). Table 1:
Receiver Gateway Number Output Format
Straight-through Modem Cable Configuration DTE
Modem Cable Pin Definitions
Baud Rate Link Test
Recommended Programming Selections Selects a number (01 to 99) that is included in every message to the computer in both D6500 and SIA modes Enable computer output messages in the selected format: SIA computer interface standard format, recommended (expanded reporting capabilities) D6500 21-character format output Use maximum speed supported by PC Tests if a supervision signal can be sent and received from the central station by the receiver
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
.
3.0 Computer Communication Protocols 3.1
D6500 Mode Messages
In D6500 Mode, the line number/group number sent to the computer is only one digit. Refer to Table 2. Table 2:
D6600 Line Number/Group Number Conversion Table
Line# /Group # L01/G01 L02/G02 L03/G03 L04/G04 L05/G05 L06/G06 L07/G07 L08/G08
Converted to 1 2 3 4 5 6 7 8
Line# /Group # L09/G09 L10/G10 L11/G11 L12/G12 L13/G13 L14/G14 L15/G15 L16/G16
Converted to 9 A B C D E F G
Line # /Group # L17/G17 L18/G18 L19/G19 L20/G20 L21/G21 L22/G22 L23/G23 L24/G24
Converted to H I J K L M N O
Line # /Group # L25/G25 L26/G26 L27/G27 L28/G28 L29/G29 L30/G30 L31/G31 L32/G32
Converted to P Q R S T U V W
In D6500 mode, any group that equals 33 is converted to an “X.” Any group greater than or equal to 34 is converted to a “Y.” For lines that are grouped, Gxx appears instead of Lxx. For networked accounts, Nxx appears instead of Lxx and the line number is identified. 3.1.1
Acron Super Fast (Message Type 9)
Acron Super Fast Example
Table 3: # 1 2 3-4 5 6-9 10-13 14-21 22
D6500 Byte Description 1 h
2 9
3 r
4 r
5 l
6 s
7 s
8 s
9 s
10 a
11 a
12 a
13 a
14 C
15 C
16 C
17 C
18 C
19 C
20 C
21 C
22 t
Message Type 9 (Acron Super Fast) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Channels Trailer Character
Description Optional. Check with the computer automation software for compatibility. 9 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. Channels 1 to 8 Typically, this is HEX 14.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
9
Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.1.2
Ademco 4-1 Express (Message Type b)
4-1 Express Example
Table 4: # 1 2 3-4 5 6-11 12-15 16 17 18-20 21 22
3.1.3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
b
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
s
s
X
t
Message Type b (Ademco 4-1 Express) Byte Description Description Optional. Check with the computer automation software for compatibility. b Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event Code, “A” as the default. Three spaces. Zone number. Typically, this is HEX 14.
Ademco 4-2 Express (Message Type c)
Table 5:
10
D6500 Byte Description
Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces X Trailer Character
4-2 Express Example
# 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 22
Computer Communication Protocols
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
c
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
s
X
Y
t
Message Type c (Ademco 4-2 Express) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces XY Trailer Character
Description Optional. Check with the computer automation software for compatibility. c Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event Code, “A” as the default. Two spaces. Event code and zone number. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.1.4
Ademco Contact-ID (Message Type a)
Contact ID Example
Table 6:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
a
r
r
l
s
a
a
a
a
1
8
Q
X
Y
Z
G
G
C
C
C
t
Message Type a (Ademco Contact ID) Byte Description
# 1 2 3-4 5 6 7-10 11-12 13 14-16 17-18 19-21 22
3.1.5
Computer Communication Protocols
Title Header Character (h) Message Type Receiver Number Line/Group Number Space Account Number 18 Qualifier XYZ GG CCC Trailer Character
Description Optional. Check with the computer automation software for compatibility. a Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Account number, four digits. Ademco Contact-ID format number Qualifier, 1=New event or opening, 3=New restore or closing, 6=Previous event. Class code and event code (see Appendix A). Group number. Zone codes or user ID. Typically, this is HEX 14.
Ademco High Speed, 4-8-1 (Message Type f) SCANCOM 4-8-1, 5-8-1, 6-8-1 - Available Upon Request
High Speed Example
Table 7:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
h
f
r
r
l
a
a
a
a
a
a
s
C
C
C
C
s
C
C
C
C
s
C
t
Message Type f (Ademco High Speed, 4-8-1) Byte Description
# 1 2 3-4 5 6-11
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number
12 13-16 17 18-21 22 23 24
Space CCCC Space CCCC Space C Trailer Character
Description Optional. Check with the computer automation software for compatibility. f Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number, up to six digits. Account number less than six characters is right aligned with leading ASCII spaces. One space. Channels 1 to 4. One space. Channels 5 to 8. One space. Supervisory channel. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
11
Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.1.6
ADT SIA (Message Type S)
ADT SIA Example
Table 8: # 1 2 3-4 5 6 7 8-11 12 13-32 33 34-35 36-39 40 41 42
3.1.7
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
h
S
r
r
l
[
#
a
a
a
a
|
d
a
m
m
-
d
d
-
y
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
y
t
I
h
h
:
m
m
:
s
s
E
M
M
Z
Z
Z
Z
/
** *
t
ADT SIA (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number space # Account Number | Date and Time E Event Code Zone / *** Trailer Character
Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. # Up to sixteen digits in the account number. Separator. Indicates more data positions after account number. Date and time. SIA block code. SIA event code (refer to Appendix G ADT SIA Report Codes on page 149). Zone number. Separator. Next block of data. Typically, this is HEX 14.
Caller ID (Message Type e)
Caller ID Example
Table 9:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
e
r
r
1
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
t
Caller ID (Message Type e) Byte Description
# 1 2 3-4 5 6-21
Title Header Character (h) Message Type Receiver Number Line/Group Number Caller ID
22
Trailer Character
12
Computer Communication Protocols
Description Optional. Check with the computer automation software for compatibility. e Receiver gateway Number from 01 to 99. Line number in the receiver gateway that sent the message. Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with leading ASCII spaces. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.1.8
CFSK (Message Type i)
CFSK Example
Table 10: # 1 2 3-4 5 6-9 10-15 16-17 18-19 20-21 22
3.1.9
Computer Communication Protocols
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
i
r
r
l
s
s
s
s
a
a
a
a
a
a
T
T
E
E
s
s
t
CFSK (Message Type i) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number TT EE Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. i Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Four spaces. Six digit account number. Event Code. Zone/User ID. Two spaces. Typically, this is HEX 14.
Common Formats (Message Type 1)
Type 1 Example
Table 11:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
l
r
r
l
a
a
a
a
a
a
a
a
a
a
E
E
y
y
y
y
t
Common Formats (Message Type 1) Byte Description
# 1 2 3-4 5 6-15
Title Header Character (h) Message Type Receiver Number Line Number Account Number
16-17
Event Code
18-21
Zone Number
22
Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number, up to ten digits. Account numbers less than ten characters are right aligned with leading ASCII spaces. Event codes define the type of signal received and interpreted by the D6500 receiver gateway. Zone or ID number sent by the communicator. Zone numbers less than four digits are right aligned with leading ASCII spaces. Typically, this is HEX 14.
The receiver gateway will sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the programmable option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
13
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.1.10 DNIS/ANI (Message Type N) DNIS/ANI Example
Table 12: # 1 2 3-4 5 6 7 8-18 19 20-30 31
D6500 Byte Description
1 H
2 N
3 r
4 r
5 l
6 s
7 D
8 d
9 d
10 d
11 d
12 d
13 d
14 d
15 d
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
d
d
&
a
a
a
a
a
a
a
a
a
16
DNIS/ANI (Message Type N) Byte Description Title Header Character (H) Message Type Receiver Number Line/Group Number Space DNIS Identifier DNIS Number ANI Identifier (&) ANI Number Trailer Character
Description Optional. Check with the computer automation software for compatibility. N (Capital n). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. DNIS identifier. DNIS number, up to 11 digits. ANI identifier. ANI number, up to 11 digits. Typically, this is HEX 14.
3.1.11 DSC 4-3 (Message Type d) DSC 4-3 Example
Table 13: # 1 2 3-4 5 6-11 12-15 16 17 18 19 20-21 22
14
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
d
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
X
Y
Y
t
DSC-4-3 (Message Type d) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Space X YY Trailer Character
Description Optional. Check with the computer automation software for compatibility. d Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event Code, “A” as the default. One space. Event code number. Zone number. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.1.12 FBI Super Fast (Message Type F) FBI Super Fast Example
Table 14: # 1 2 3-4 5 6-11 12-15 16 17-18 19 20-21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
F
r
r
l
s
s
s
s
s
s
a
a
a
a
T
Z
Z
E
s
s
t
FBI Super Fast (Message Type F) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number T ZZ E Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. F (Capital f). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. Zone type. Zone number. Event type. Two spaces. Typically, this is HEX 14.
3.1.13 ITI (Message Type I) ITI Example
Table 15: # 1 2 3-4 5 6-8 9 10 11-14 15 16 17-18 19 20 21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
I
r
r
l
s
s
s
a
T
a
a
a
a
G
I
Z
Z
E
W
N
t
ITI (Message Type I) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Panel Type Account Number G I ZZ E W N Trailer Character
Description Optional. Check with the computer automation software for compatibility. I (Capital i). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Three spaces. First digit account number. Control panel Type. Next four digit account number. Group number. Open/close (O/C) User ID. Zone number. Condition code. Protection level was. Protection level is. Typically, this is HEX 14.
3.1.14 Link Test (Message Type 1) Link Test Example
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
1
r
r
0
s
s
s
s
s
s
s
s
s
s
s
@
s
s
s
s
t
The D6600/D6100 can automatically generate this message at the programmed intervals.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
15
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Table 16: # 1 2 3-4 5 6-15 16-17 18-21 22
Computer Communication Protocols
Link Test (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line Number Spaces Event Code Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number as zero for link test. Eleven spaces. Event code is @ for link test. Four spaces. Typically, this is HEX 14.
3.1.15 Robofon (Message Type j) Robofon Example
Table 17: # 1 2 3-4 5 6-9 10-15 16-17 18-21 22
16
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
j
r
r
l
s
s
s
s
a
a
a
a
a
a
E
E
s
s
s
s
t
Robofon (Message Type j) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number EE Spaces Trailer Character
Description Optional. Check with the computer automation software for compatibility. j Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Four spaces. Six digit account number. Event code. Four spaces. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.1.16 Sescoa Super Speed (Message Type 7) Sescoa Super Speed Example
Table 18: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20 21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
7
r
r
l
s
s
s
s
s
s
a
a
a
a
s
I
A
A
C
s
t
Sescoa Super Speed (Message Type 7) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space I AA C s Trailer Character
Description Optional. Check with the computer automation software for compatibility. 7 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event code. Two digit zone code or the first two digits user code. Space if zone report, or the last digit user code. One space. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
17
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.1.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Scancom 4-16-1, 5-16-1, 6-16-1 Example
Table 19:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
h
g
r
r
l
a
a
a
a
a
a
s
C
C
C
C
s
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
C
C
C
C
s
C
C
C
C
s
C
C
C
C
s
C
t
Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description
# 1 2 3-4 5 6-11
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number
12 13-16 17 18-21 22 23-26 27 28-31 32 33 34
Space CCCC Space CCCC Space CCCC Space CCCC Space C Trailer Character
18
Description Optional. Check with the computer automation software for compatibility. g Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number up to six digits. Account numbers less than six characters are right aligned with leading ASCII spaces. One space. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Supervisory channel. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.1.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Scancom 4-24-1 Example
Table 20:
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
h
r
r
l
a
a
a
a
a
a
s
C
C
C
C
s
C
C
C
C
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43 44
C
C
C
C
s
C
C
C
C
s
C
C
C
C
s
C
C
C
C
s
C
s t
Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description
# 1 2 3-4 5 6-11
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number
12 13-16 17 18-21 22 23-26 27 28-31 32 33-36 37 38-41 42 43 44
Space CCCC Space CCCC Space CCCC Space CCCC Space CCCC Space CCCC Space C Trailer Character
Description Optional. Check with the computer automation software for compatibility. h Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number up to six digits. Account numbers less than six characters are right aligned with leading ASCII spaces. One space. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Channels 17 to 20. One space. Channels 21 to 24. One space. Supervisory channel. Typically, this is HEX 14.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
19
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.1.19 Seriee FSK (Message Type k) Seriee FSK Example
D6500 Byte Description
Table 21: # 1 2 3-4 5 6-11 12-16 17 18 19 20 -21 22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
h
k
r
r
l
s
s
s
s
s
s
a
a
a
a
a
s
E
s
Z
Z
t
20
21 22
Seriee FSK (Message Type k) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Space ZZ Trailer Character
Description Optional. Check with the computer automation software for compatibility. k Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Five digit account number. One space. Event code. One space. Zone number. Typically, HEX 14.
3.1.20 Seriee DTMF (Message Type l) Seriee DTMF Example
Table 22: # 1 2 3-4 5 6-7 8 9-14 15 16-21 22
20
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
h
l
r
r
l
L
L
*
a
a
a
a
a
a
*
16
17
18
19
. . .
t
Seriee DTMF (Message Type l) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number LL * Account number * *** Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 (lowercase L). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Data length. Data separator. Four, five or six account numbers. Data separator. DTMF Seriee Data. Typically, HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.1.21 SIA (Message Type S) Defined Messages SIA Example
D6500 Byte Description
Table 23: # 1 2 3-4 5 6 7 8-11 12 13 14-15 16-19 20 21 22
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
h
S
r
r
l
[
#
a
a
a
a
|
E
M
M
Z
Z
Z
Z
/ ***]
21
22
t
SIA (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number [ # Account Number | E Event Code Zone / ***] Trailer Character
Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Open bracket. # Up to sixteen digits may be used in the account number. Separator, indicates more data positions after account number. SIA block code. SIA Event code. Zone number. Separator. Next block of data. Typically, HEX 14.
Undefined Messages When an SIA message contains unprintable characters (unprintable characters are out of ASCII range 0x32-0x7E) or without an account block: SIA Example
Table 24: # 1
D6500 Byte Description 1
2
3
4
5
6
h
S
r
r
L
[
.
. .
data
N-1
N
]
t
SIA (Message Type S) Byte Description
6 7-(N-2)
Title Header Character (h) Message Type Receiver Number Line/Group Number [ data
N
Trailer Character
2 3-4 5
7
Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Open bracket. The received SIA message contains hex characters either with or without account portion. Typically, HEX 14.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
21
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.1.22 Silent Knight FSK0 (Message Type 1) Silent Knight FSK0 Example
Table 25: # 1
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
1
r
r
l
s
s
s
s
s
s
a
a
a
a
s
E
s
s
s
Z
20
21 22
Silent Knight FSK1 (Message Type m) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Spaces E Space Zone number Trailer Character
2 3-4 5 6-11 12-15 16 17 18-20 21 22
t
Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Four digit account number. One space. Event code. Three spaces. Zone number. Typically, HEX 14.
Optional Silent Knight SK1 (Message Type m): If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to 1, the following output is used. Silent Knight FSK1 Example
D6500 Byte Description 1 h
Table 26: # 1
2 m
3 r
6 7-14 15 16-17 18 19 21
“ ZZ “ *** Trailer Character
22
5 l
6 s
7 a
8 a
9 a
10
11
12
13
14
15
16
17
18
a
a
a
a
a
“
Z
Z
“
19
. . .
t
Optional Silent Knight SK1 (Message Type m) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number
2 3-4 5
4 r
Description Optional. Check with the computer automation software for compatibility. m Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Maximum eight-digit account code. If the account code is less than eight digits, enter the actual number of digits without a leading space. Separator. First zone number, up to eight reports, one report has two digits. Separator. More data. Typically, HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. Table 27:
Silent Knight Automation Format
Report Code
Description
00: 01 to 08: 09: 10 to 19: 20 to 29: 30: 31: 32: 33: 34: 35: 36: 37: 38: 39: 40: 41 to 49: 50 to 59: 60: 61 to 68: 69: 70: 71 to 78: 79: 80: 81 to 89: 90: 91 to 99:
Alarm Panic Alarm 01 to 08 Holdup Alarm 10 to 19 Alarm Restore 10 to 19 Test Code Trouble Line 1 Trouble Line 2 Expand Trouble Forced Access Restore Line 1 Restore Line 2 Expand Restore Cancel Code Data Lost Closing Closing 01 to 09 Bypass 10 to 19 Trouble AC Trouble 01 to 08 Trouble BAT Restore AC Restore 01 to 08 Restore BAT Access Access 01 to 09 Opening Opening 01 to 09
To Automation 2 5 16=0(EEZZ) PAss sA0x Hass sA1x sH1x sXss LT01 LT02 ETss DFss LR01 LR02 ERss OCss RTss CL00 CL0x sB1x ATss sT0x YTss ARss sRss YRss DS00 DG0x OP00 OP0x
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
2 5 16=1(ZZ) 00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 80 to 89 90 91 to 99
Note
x=1 to 8 x=0 to 9 x=0 to 9
x=1 to 9 x=0 to 9 x=1 to 8
x=1 to 9
23
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.1.23 Silent Knight FSK2 (Message Type m) Silent Knight FSK2 Example
Table 28: # 1
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
m
r
r
l
s
a
a
a
a
a
a
a
a
“
E
E
Z
Z
“
* * *
Silent Knight FSK2 (Message Type m) Byte Description
6 7-14
Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number
15 16-19
“ EEZZ
20 21 22
“ *** Trailer Character
2 3-4 5
t
Description Optional. Check with the computer automation software for compatibility. m Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Maximum eight-digit account code. If the account code is less than eight digits, enter the actual number of digits without a leading space. Separator. First event and zone number. If this is the only event, it will be ended with the terminator. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, two-digit zone code. Separator. Next data. Typically, HEX 14.
3.1.24 Silent Knight FSK80 D6500 mode (Message Type E) Silent Knight FSK80 Example
Table 29: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 24
24
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
E
r
r
l
s
s
s
s
s
s
A
A
A
A
s
A
s
s
X
Y
t
Silent Knight FSK80 (Message Type E) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space Filler character A Spaces XY Trailer Character
Description Optional. Check with the computer automation software for compatibility. E Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message.
Four-digit account number. Always char “A”. Two-digit alarm zone code. Typically, HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.1.25 Telim (Message Type n) Telim Example
Table 30: # 1 2 3-4 5 6 7-12 13 14 15-32 33
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
h
n
R
R
L
s
A
A
A
A
A
A
s
E
T
T
Z
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
t
Z
Telim (Message Type n) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Space Account Number Space E TTZZZZZZZZZZZZ Trailer Character
Description Optional. Check with the computer automation software for compatibility. n Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Six digit account number. One space. Event code. Input line number. Typically, HEX 14.
3.1.26 Text Message (Message Type 3) Type 3 Example
Table 31: # 1 2 3-4 5 6-21 22
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
h
3
r
r
l
P
R
I
N
T
E
R
13
14
15
16
17
18
19
20
21 22
v
v
.
v
v
t
Text Message (Message Type 3) Byte Description Title Header Character (h) Message Type Receiver Number Line Number Message Text Trailer Character
Description Optional. Check with the computer automation software for compatibility. 3 Receiver gateway number from 01 to 99. Line number fixed at 1. Sixteen characters in length. Typically, HEX 14.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
25
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.1.27 Varitech FSK 4-1 (Message Type 1) Varitech FSK 4-1 D6500 Byte Description Example 1 2 3 4 5 6
h Table 32: # 1 2 3-4 5 6-11 12-15 16 17 18-20 21 22
1
r
r
l
s
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
s
s
s
s
s
a
a
a
a
s
E
s
s
s
X
t
Varitech FSK 4-1 (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces X Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Four digit account number. One space. Event code. Three spaces. Zone number. Typically, HEX 14.
3.1.28 Varitech FSK 4-2 (Message Type 1) Varitech FSK 4-2 D6500 Byte Description Example 1 2 3 4 5 6
h Table 33: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 22
26
1
r
r
l
s
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
s
s
s
s
s
a
a
a
a
s
E
s
s
X
Y
t
Varitech FSK 4-2 (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces XY Trailer Character
Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Four digit account number. One space. Event code. Two spaces. Zone number. Typically, HEX 14.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.1.29 VONK (Message Type V) D6500 Byte Description 1 2 3 4 5 6 h V r r l A
VONK Example
Table 34: # 1
8 1
9 2
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3 4 5 6 7 8 9 A B C D E F G t
VONK (Message Type V) Byte Description
6-7 8-23
Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number Zone status
24
Trailer Character
2 3-4 5
7 A
Description Optional. Check with the computer automation software for compatibility. V Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Two digit account number. Status of zones 1 to 16. If the zone is Closed, a “.”(Period) is in this position. If the zone is Open, 1 to G appears in this position. Typically, HEX 14
3.1.30 X-SIA Text (Message Type S) X-SIA Example
Table 35: # 1 2 3-4 5 6 7 8-11 12 13 14-15 16-19 20 21 22-34 35 36-37 38 39-41 42
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21 22
h
S
r
r
l
[
#
a
a
a
a
|
E
M
M
Z
Z
Z
Z
*
`
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
T
T
T
T
T
T
T
T
T
T
T
T
‘
N
M
/
*
*
*
t
T
X-SIA Text (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number [ # Account Number | E MM ZZZZ * ‘ TT…T ‘ NM / *** Trailer Character
Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Open bracket. # Use up to sixteen digits in the account number. Separator. Indicates more data positions after account number. SIA block code. SIA event code. Zone number. Text identifier. Quotation mark (single). 13 character text string. Qutotation mark (single). Unit field characters. Separator. Next block of data. Typically, HEX 14.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
27
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.1.31 SafeCom (Message Type p) SafeCom Example
Table 36: # 1 2 3-4 5 6-9 10-13 14-(N-1) N
3.2
D6500 Byte Description 1
2
3
4
5
6
7
8
9
10
11
12
13
h
p
r
r
l
A
A
A
A
E
E
E
E
14
...
N-1
. . . data . . .
N
t
SafeCom (Message Type p) Byte Description Title Header Character (h) Message Type Receiver Number Line Card Number Account Number Event Code Data Trailer Character
Description Optional. Check with the computer automation software for compatibility. p Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Four digits. Four digits. Parameter data for event code. Typically, HEX 14.
SIA Mode Messages
Use the SIA mode for central station monitoring. 3.2.1 Acron Super Fast (Message Type 9) Acron Super Fast Example
Table 37:
Acron Super Fast (Message Type 9) Byte Description
Title L CRC Message Type sequence# receiver# line# (Line/Group #) account#
Figure 7:
SIA Mode Description <9>[#aaaa|CCCCCCCC]
Description Standard line feed character. Cyclical redundancy check number. 9 The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits.
Message sent to printer
Table 38:
Acron Super Fast (Message Type 9) Printer Output
mm/ddshh:mmsLxxsACNsACCTsaaaa +++sACCTsaaaasCCCCsCCCC For lines that are grouped, Gxx appears instead of Lxx.
28
Characters ACN Lxx Gxx
Description Acron Super Fast format. Line number. Grouped line numbers.
Bosch Security Systems, Inc. | 8/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.2.2
Computer Communication Protocols
Ademco Contact-ID (Message Type a)
Contact-ID Example
Table 39:
SIA Mode Description [#aaaa|18QXYZGGCCC]
Ademco Contact-ID (Message Type a) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# 18 Q XYZ GG CCC
Figure 8:
Description Standard line feed character. Cyclical redundancy check number. a The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Ademco Contact-ID format number. Qualifier, 1 = New event or opening, 3 = New restore or closing, 6 = Previous event. Class code and event code (refer to Appendix A: Contact ID Event Code Classifications on page 53). Group number. Zone codes or User ID.
Message sent to printer
Table 40:
Ademco Contact-ID (Message Type a) Printer Output
mm/ddshh:mmsLxxsCIDsACCTsaaaa +++sACCTsaaaasNNNsEVENT=XYZsG=GGsC=CCC For lines that are grouped, Gxx appears instead of Lxx.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Characters CID Gxx Lxx NNN
Description Contact-ID format. Grouped Line numbers. Line number. If Q = 1, print E/O for new event or opening If Q = 3, print R/C for restore or closing If Q = 6, print “OLD” for old messages and events.
29
Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.2.3
Computer Communication Protocols
Ademco 4-1 Express (Message Type b)
4-1 Express Example
Table 41:
SIA Mode Description [#aaaa|X]
Ademco 4-1 Express (Message Type b) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# X
Figure 9:
Description Standard line feed character. Cyclical redundancy check number. b The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Zone number
Message sent to printer
mm/ddshh:mmsLxxsE41sACCTsaaaasEVENT=X For lines that are grouped, Gxx appears instead of Lxx. Table 42:
Characters E41 Lxx: Gxx
30
Ademco 4-1 Express (Message Type b) Printer Output Description Ademco 4-1 Express format. Line number. Grouped line numbers.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.2.4
Ademco 4-2 Express (Message Type c)
4-2 Express Example
Table 43:
SIA Mode Description [#aaaa|XY]
Ademco 4-2 Express (Message Type c) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# XY
Description Standard line feed character. Cyclical redundancy check number. c The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code and Zone number.
Figure 10: Message sent to printer mm/ddshh:mmsLxxsE42sACCTsaaaasEVENT=XY For lines that are grouped, Gxx appears instead of Lxx. Table 44:
Characters E42 Lxx: Gxx
Ademco 4-2 Express (Message Type c) Printer Output Description Ademco 4-2 Express format. Line number. Grouped line numbers.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
31
Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.2.5
Computer Communication Protocols
Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) SCANCOM 5-8-1, 6-8-1 - available upon request
High Speed Example
Table 45:
SIA Mode Description [#aaaaaa|CC CCsCCCCsC]
Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# CCCC s CCCC s C
Description Standard line feed character. Cyclical redundancy check number. f The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Channels 1 to 4. One space. Channels 5 to 8. One space. Supervisory channel.
Figure 11: Message sent to printer
Table 46:
Ademco High Speed, 4-8-1 (Message Type f) Printer Output
mm/ddshh:mmsLxxsHGHsACCTsaaaaaa +++sACCTsaaaaaasCCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx.
32
Characters HGH Lxx: Gxx
Description Ademco High Speed format. Line number. Grouped line numbers.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.2.6
ADT SIA (Message Type )
ADT SIA Example
Table 47:
SIA Mode Description [#aaaa|data]
ADT SIA (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# E damm-dd-yytihh:mm:ss Data
3.2.7
Computer Communication Protocols
Description Standard line feed character. Cyclical redundancy check number. 09 hex . The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number up to sixteen digits. Event Code (refer to Appendix G ADT SIA Report Codes on page 149). Date and time. This field contains message data codes such as event type, area number, point number, identification number.
Caller ID (Message Type )
SIA Example
Table 48:
SIA Mode Description [&TTTTTTTTTTTTTTTT]
Caller ID (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) & T
Description Standard line feed character. Cyclical Redundancy Check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. Origin ID Block. Up to 16-digit Caller ID.
Figure 12: Message sent to Printer [#0000 | &TTTTTTTTTTTTTTTT]
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
33
Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.2.8
CFSK (Message Type I)
CFSK Example
Table 49:
SIA Mode Description [#aaaaaa|TTEE]
CFSK (Message Type I) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # TT EE
3.2.9
Computer Communication Protocols
Description Standard line feed character. Cyclical redundancy check number. I (Capital I). The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, up to six digits. Event code. Zone/User ID.
Common Formats (Message Type )
Defined Messages SIA Example
Table 50:
SIA Mode Description [#aaaaaaaaaaaaaaaa|data]
Common Formats (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# Data
Description Standard line feed character. Cyclical Redundancy Check number. 09 hex The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number up to sixteen digits. This field contains message data codes such as event type, area number, point number, identification number, and so on.
The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the program option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the programmable option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions. Figure 13: Message sent to printer MM/DDsHH:MMsLxxSIA ACCT aaaa +++ TEXT 1 +++ TEXT 2
34
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. Undefined Messages When a common format message contains unprintable hex characters (unprintable characters are out of ASCII range 0x32-0x7E) or without an account block: SIA Example
SIA Mode Description [data]
Table 51: Common Formats (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver#
Description Standard line feed character. Cyclical Redundancy Check number. 09 hex. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100i. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The D6600/D6100i uses Line 0 (zero) for receiver gateway messages. The receiver message contains hex characters either with or without account portion.
line# (Line/Group #) Data
Figure 14: Message sent to printer MM/DDsHH:MMsLxx[SIA] +++ TEXT 1 +++ TEXT 2 3.2.10 DNIS/ANI (Message Type N) SIA Example
Table 52:
SIA Mode Description [#0000|Dddddddddddd&aaaaaaaaaa]
DNIS/ANI (Message Type N) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# D DNIS number (d) ANI identifier (&) ANI number (a)
Description Standard line feed character. Cyclical redundancy check number. N The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. Fixed at 0000. DNIS identified. DNIS number, up to 11 digits. ANI identifier. ANI number, up to 11 digit.s
Figure 15: Message sent to printer MM/DDsHH:MMsLxxsDNISsddddddddddd +++sANIsaaaaaaaaaaa
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
35
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.2.11 DSC 4-3 (Message Type d) DSC4-3 Example
Table 53:
SIA Mode Description [#aaaa|XYY]
DSC 4-3 (Message Type d) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# X YY
Description Standard line feed character. Cyclical redundancy check number. d The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code number. Zone number.
Figure 16: Message sent to printer
Table 54:
DSC 4-3 (Message Type d) Printer Output
mm/ddshh:mmsLxxsDSGsACCTsaaaasEVENT=XYY +++sACCsaaaaseeeeeeeesiisnnn
For lines that are grouped, Gxx appears instead of Lxx.
Table 55:
Event Code Table
Code Number
Message
1 2 3 4 5 6 7 8 9 0 B C D E F
Alarm
36
Close Open Alarm
Restore Trouble CloseGrp OpenGrp Bypass UnBypass Cancel
Characters DSG Lxx: Gxx
Table 56: Event Characters A A A C O A A A R T C O B H O
Characters ii nnn eeeeeeee
Description DSC/Sur-Gard 4-3 format. Line number. Grouped line numbers.
Printer Output Codes Description ZN=Zone number - ID=User ID Zone/User number. Up to eight-character event type, right justified – ALARM, RESTORE, TROUBLE, OPEN, OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.2.12 FBI Super Fast (Message Type F) FBI Super Fast Example
Table 57:
SIA Mode Description [#aaaa|TZZE]
FBI Super Fast (Message Type F) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# T ZZ E
Description Standard line feed character. Cyclical redundancy check number. F The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Zone type. Zone number. Event type.
Figure 17: Message sent to printer
Table 58:
mm/ddshh:mmsLxxsFBIsACCTsaaaasETsnnn +++sACCTsaaaastttttttttseeeeeeeesZNsnnn
For lines that are grouped, Gxx appears instead of Lxx.
Table 59: Code 1 2 3 4 5 6 7 8 9 0 B C D E F
Event Code Table Zone/Event Type Fire Panic Burglary Medical Auxiliary Bypass Inactive Eight Nine Zero Opening Closing Abort Restore Trouble
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
FBI Super Fast (Message Type F) Printer Output
Characters FBI Lxx: Gxx
Description FBI Super Fast format. Line number. Grouped line numbers.
Table 60:
Printer Output Codes
Characters ZN nnn ttttttttt
eeeeeeee
Description ZN=Zone number - ID=User ID Zone/User number. Up to nine-character zone type, right justified FIRE, PANIC, BURGLARY, MEDICAL, AUXILIARY. Up to eight-character event type, left justified ALARM, RESTORE, TROUBLE, OPEN, OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL.
37
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.2.13 ITI (Message Type I) ITI Example
Table 61:
SIA Mode Description [#aaaaa|GIZZEWN]
ITI (Message Type I) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# G I ZZ E W N
Description Standard line feed character. Cyclical redundancy check number. I (Captial I). The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Group number. O/C User ID. Zone number. Condition code. Protection level was. Protection level now.
3.2.14 Link Test (Message Type ) Link Test Example
SIA Mode Description []
The D6600/D6100 can automatically generate this message at the preprogrammed intervals. Table 62:
Link Test (Message Type ) Description
Title LF CRC Message Type sequence# receiver#
38
Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.2.15 RB2000 (Message Type R) Description RB2000 Example
Table 63:
SIA Mode Description []
RB2000 (Message Type R) Byte Description
Title LF CRC R sequence# Receiver# line# CR
Description Standard line feed character, hex 0A. Cyclical redundancy check number. ASCII R, Message Type R for RB2000 format. The message sequence number. The valid sequence number range: 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. VDS message sent as a hex string, the receiver extracts the alarm type. Hex 0D
Figure 18: Single message sent to Printer
Table 64:
RB2000 (Message Type R) Printer Output
MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ RB2000_EVENT_RAW_DATA Figure 19: Multiple messages sent to printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ RB2000_EVENT_RAW_DATA 1 +++ RB2000_EVENT_RAW_DATA 2 ... +++ RB2000_EVENT_RAW_DATA n
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Characters
Description
MM/DDsHH:MM RB2 Lxx ACCT xxxxxxxxxxxx
Date and time. RB2000 format. Line number. Subscriber number, up to 12 characters(hex). The raw data of RB2000 event.
RB2000_EVENT_RAW _DATA RB2000_EVENT_RAW _DATA1 RB2000_EVENT_RAW _DATA 2 RB2000_EVENT_RAW _DATA n
The raw data of RB2000 event 1. The raw data of RB2000 event 2. The raw data of RB2000 event n.
39
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.2.16 Robofon (Message Type j) Robofon Example
Table 65:
SIA Mode Description [#aaaaaa|EE]
Robofon (Message Type j) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EE
Description Standard line feed character. Cyclical redundancy check number. j The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Event code.
3.2.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) 4-16-1 Example
Table 66:
Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) Account# CCCC s CCCC s CCCC s CCCC s C
40
SIA Mode Description [#aaaaaa|CCCCsCCCCsCCCCsCCCCsC]
Description Standard line feed character. Cyclical redundancy check number. g The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Supervisory channel.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. Figure 20: Message sent to printer
Table 67:
mm/ddshh:mmsLxxsSCNsACCTsaaaaaa +++sACCTsaaaaaasCCCCsCCCCsCCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx.
Scancom 4-16-1, 5-16-1, 6-16-1 Available Upon Request (Message Type g) Printer Output
Characters SCN Lxx: Gxx
Description Scancom. Line number. Grouped line numbers.
3.2.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) 4-24-1 Example
Table 68:
SIA Mode Description [#aaaaaa|CCCCsCCCCs CCCCs CCCCsCCCCsCCCCsC]
Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# CCCC s CCCC s CCCC s CCCC s CCCC s CCCC s C
Description Standard line feed character. Cyclical redundancy check number. h The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, up to six digits. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Channels 17 to 20. One space. Channels 21 to 24. One space. Supervisory channel.
Figure 21: Message sent to printer
Table 69:
mm/ddshh:mmsLxxsSCNsACCTsaaaaaa +++sACCTsaaaasCCCCsCCCCsCCCCsCCCC ++++++++++++++CCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Characters SCN Lxx: Gxx
Scancom 4-24-1, 5-24-1, 6-24-1 Available Upon Request (Message Type h) Printer Output Description Scancom. Line number. Grouped line numbers.
41
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.2.19 Seriee DTMF (Message Type l) Seriee DTMF Example
Table 70:
SIA Mode Description [#aaaa|*data]
Seriee DTMF (Message Type l) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # * Data
Description Standard line feed character. Cyclical redundancy check number. l (lowercase L). The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Data separator. DTMF Seriee Data.
3.2.20 Seriee FSK (Message Type k) Seriee FSK Example
Table 71:
SIA Mode Description [#aaaaa|EZZ]
Seriee FSK (Message Type k) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) Account # E ZZ
42
Description Standard line feed character. Cyclical redundancy check number. k The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Event code. Zone number.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.2.21 Sescoa Super Speed (Message Type 7) Sescoa Super Speed Example
Table 72:
SIA Mode Description
Sescoa Super Speed (Message Type 7) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# I AA C
Description Standard line feed character. Cyclical redundancy check number. 7 The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code. Two- digit zone code or the first two digits user code. Space if zone report, or the last digit user code.
Figure 22: Message sent to printer
Table 73:
Sescoa Super Speed (Message Type 7) Printer Output
mm/ddshh:mmsLxxSESsACCTsaaaa +++sACCTsaaaasEEEseeeeeeeeeeeeee For lines that are grouped, Gxx appears instead of Lxx.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Characters SES Lxx Gxx aaaa EEE eeeeeeeeeeeeee
Description SESCOA Super Speed format. Line number. Grouped line numbers. Account code. SESCOA Super Speed format event. Up to 14-characters of event description.
43
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.2.22 Silent Knight FSK() (Message Type ) Silent Knight FSK0 Example
Table 74:
SIA Mode Description [#aaaa|data]
Silent Knight FSK0 (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # Data
Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Data.
3.2.23 Silent Knight FSK1 (Message Type m) Silent Knight FSK1 Example
Table 75:
SIA Mode Description [#aaaa| EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ]
Silent Knight FSK1 (Message Type m) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EEZZ”EEZZ”EEZZ”EEZZ” EEZZ”EEZZ”EEZZ”EEZZ
44
Description Standard line feed character. Cyclical redundancy check number. m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, and two-digit zone code. The quote (“) is the separation character.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. Optional Silent Knight FSK1 (Message Type m) If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to1, the following output is used. Silent Knight FSK1 Example
Table 76:
SIA Mode Description [#aaaa|ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ]< CR>
Optional Silent Knight FSK1 (Message Type m) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”Z Z
Table 77:
Description Standard line feed character. Cyclical redundancy check number. m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Up to eight reports. One report has two digits. The quote (“) is the separate character.
Silent Knight FSK1 Optional Outputs
Report Code
Description
To Automation 2 5 16 = 0(EEZZ)
2 5 16 = 1(ZZ)
00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 81 to 89
Alarm Panic Alarm 01 to 08 Holdup Alarm 10 to 19 Alarm Restore 10 to 19 Test Code Trouble Line 1 Trouble Line 2 Expand Trouble Forced Access Restore Line 1 Restore Line 2 Expand Restore Cancel Code Data Lost Closing Closing 01 to 09 Bypass 10 to 19 Trouble AC Trouble 01 to 08 Trouble BAT Restore AC Restore 01 to 08 Restore BAT Access Access 01 to 09
PAss sA0x Hass sA1x sH1x sXss LT01 LT02 ETss DFss LR01 LR02 ERss OCss RTss CL00 CL0x sB1x ATss sT0x YTss ARss sRss YRss DS00 DG0x
00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 80 to 89
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Note
x = 1 to 8 x = 0 to 9 x = 0 to 9
x = 1 to 9 x = 0 to 9 x = 1 to 8
x = 1 to 9
45
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Table 77:
Computer Communication Protocols
Silent Knight FSK1 Optional Outputs (continued)
Report Code
Description
To Automation
90 91 to 99
Opening Opening 01 to 09
OP00 OP0x
Note 90 91 to 99
3.2.24 Silent Knight FSK2 (Message Type m) Silent Knight FSK2 Example
Table 78:
SIA Mode Description [#aaaaaa| EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ]
Silent Knight FSK2 (Message Type m) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EEZZ”EEZZ”EEZZ”EEZZ” EEZZ”EEZZ”EEZZ”EEZZ
46
Description Standard line feed character. Cyclical redundancy check number. m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, and two-digit zone code. The quote (“) is the separation character.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.2.25 Silent Knight FSK80 (Message Type E) Silent Knight FSK80 Example
Table 79:
SIA Mode Description [#AAAA|NBAXY]
Silent Knight FSK80 (Message Type E) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # NBA
Description Standard line feed character. Cyclical redundancy check number. E The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Alarm event
Figure 23: Message sent to printer MM/DDsHH:MMsLxxsSFKsACCTsAAAA +++ACCTsAAAAsALARM_ZNs1 +++ACCTsAAAAsALARM_ZNs2 +++ACCTsAAAAsALARM_ZNs3 +++ACCTsAAAAsALARM_ZNs4 +++ACCTsAAAAsALARM_ZNs5 +++ACCTsAAAAsALARM_ZNs7 +++ACCTsAAAAsALARM_ZNs8 +++ACCTsAAAAsALARM_ZNs9
Table 80:
Characters MM/DDsHH:MM SFK Lxx AAAA s
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Silent Knight FSK80 Printer/LCD output Description Date and time. SFSK80 format. Line number. The communicator's account number has four digits. Space.
47
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.2.26 Telim (Message Type n) Telim Example
Table 81:
SIA Mode Description [#aaaaaa|EETTZZZZZZZZZZZZZZZZZZ]
Telim (Message Type n) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EETTZZZZZZZZZZZZZZZZ ZZ
Description Standard line feed character. Cyclical redundancy check number. n The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. The event type and input line number.
3.2.27 Varitech FSK 4-1 (Message Type ) Varitech FSK 4-1 Example
Table 82:
Varitech FSK 4-1 (Message Type ) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# data
48
SIA Mode Description [#aaaa|data]
Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99 The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. The event type and 1-digit zone number.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
. 3.2.28 Varitech FSK 4-2 (Message Type ) Varitech FSK 4-2 Example
Table 83:
SIA Mode Description [#aaaa|data]
Varitech FSK 4-2 (Message Type ) Byte Description
Title LF CRC Message sequence# receiver# line# (Line/Group #) account # data
Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. The event type and two-digit zone number.
3.2.29 VONK (Message Type V) VONK Example
Table 84:
SIA Mode Description [#aa|123456789ABCDEFG]
VONK (Message Type V) Byte Description
Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # Data
Description Standard line feed character. Cyclical redundancy check number. V The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has two digits. Status of zones 1 to 16. If the zone is closed, a “.” (Period) appears in this position. If the zone is open, any digit from 1 to G appears in this position.
Bosch Security Systems, Inc. | 9/07 | 4998122703-02
49
Conettix D6600/D6100i | Computer Interface Manual | 3.0
Computer Communication Protocols
3.2.30 X-SIA text (Message Type ) X-SIA Example
Table 85:
SIA Mode Description