Conettix D6600/D6100i Computer Interface Manual EN Receiver/Gateway Conettix D6600/D6100i | Computer Interface Manual | Trademarks Trademarks Microsoft®, Windows®, Windows NT® are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. 2 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Contents . Contents 1.1 1.2 2.0 2.1 2.2 3.0 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 3.1.7 3.1.8 3.1.9 3.1.10 3.1.11 3.1.12 3.1.13 3.1.14 3.1.15 3.1.16 3.1.17 3.1.18 3.1.19 3.1.20 3.1.21 3.1.22 3.1.23 3.1.24 3.1.25 3.1.26 3.1.27 3.1.28 3.1.29 3.1.30 3.1.31 3.2 Conettix D6680 Ethernet Network Adapter Connection..........................................................7 Direct Connection – RS-232 .............................7 Making the Right Connection.......................8 COM3 DB9 Connector .....................................8 Selecting Program Options in the D6600/D6100i ....................................................8 Computer Communication Protocols..........9 D6500 Mode Messages......................................9 Acron Super Fast (Message Type 9).................9 Ademco 4-1 Express (Message Type b).........10 Ademco 4-2 Express (Message Type c) .........10 Ademco Contact-ID (Message Type a)..........11 Ademco High Speed, 4-8-1 (Message Type f) ..............................................11 ADT SIA (Message Type S)............................12 Caller ID (Message Type e) ............................12 CFSK (Message Type i) ...................................13 Common Formats (Message Type 1) .............13 DNIS/ANI (Message Type N) ........................14 DSC 4-3 (Message Type d)..............................14 FBI Super Fast (Message Type F) ...................15 ITI (Message Type I) .......................................15 Link Test (Message Type 1) ............................15 Robofon (Message Type j)...............................16 Sescoa Super Speed (Message Type 7) ..........17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ....................18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)....................19 Seriee FSK (Message Type k) .........................20 Seriee DTMF (Message Type l) ......................20 SIA (Message Type S)......................................21 Silent Knight FSK0 (Message Type 1) ...........22 Silent Knight FSK2 (Message Type m) ..........24 Silent Knight FSK80 D6500 mode (Message Type E) .............................................24 Telim (Message Type n) ..................................25 Text Message (Message Type 3) .....................25 Varitech FSK 4-1 (Message Type 1)...............26 Varitech FSK 4-2 (Message Type 1)...............26 VONK (Message Type V)...............................27 X-SIA Text (Message Type S) ........................27 SafeCom (Message Type p).............................28 SIA Mode Messages.........................................28 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 3.2.1 3.2.2 3.2.3 3.2.4 3.2.5 Acron Super Fast (Message Type 9) .............. 28 Ademco Contact-ID (Message Type a) ......... 29 Ademco 4-1 Express (Message Type b) ........ 30 Ademco 4-2 Express (Message Type c)......... 31 Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) .................................... 32 3.2.6 ADT SIA (Message Type ) ................ 33 3.2.7 Caller ID (Message Type ) ................ 33 3.2.8 CFSK (Message Type I) .................................. 34 3.2.9 Common Formats (Message Type ) . 34 3.2.10 DNIS/ANI (Message Type N)........................ 35 3.2.11 DSC 4-3 (Message Type d) ............................. 36 3.2.12 FBI Super Fast (Message Type F) .................. 37 3.2.13 ITI (Message Type I)....................................... 38 3.2.14 Link Test (Message Type ) ................ 38 3.2.15 RB2000 (Message Type R) Description ........ 39 3.2.16 Robofon (Message Type j) .............................. 40 3.2.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ................... 40 3.2.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) ................... 41 3.2.19 Seriee DTMF (Message Type l)...................... 42 3.2.20 Seriee FSK (Message Type k) ......................... 42 3.2.21 Sescoa Super Speed (Message Type 7).......... 43 3.2.22 Silent Knight FSK() (Message Type ) ............................................................ 44 3.2.23 Silent Knight FSK1 (Message Type m).......... 44 3.2.24 Silent Knight FSK2 (Message Type m).......... 46 3.2.25 Silent Knight FSK80 (Message Type E) ........ 47 3.2.26 Telim (Message Type n).................................. 48 3.2.27 Varitech FSK 4-1 (Message Type ).. 48 3.2.28 Varitech FSK 4-2 (Message Type )... 49 3.2.29 VONK (Message Type V) .............................. 49 3.2.30 X-SIA text (Message Type ) .............. 50 3.2.31 SafeCom (Message Type p) ............................ 51 3.3 Input Command Processing ........................... 52 Appendix A: Contact ID Event Code Classifications................................................. 53 Appendix B: Internal Messages................................ 58 Appendix C: Modem IIIa2 Messages ....................... 61 C.1 Zonex and Comex Translation .................... 137 Appendix D: Network Messages............................ 138 Appendix E: Pulse Output ....................................... 141 Appendix F: Format ID (by Message Type) – D6600 Only .................................................. 146 3 Conettix D6600/D6100i | Computer Interface Manual | Contents Appendix G: ADT SIA Report Codes ...................149 Appendix H: RB2000 Messages (D6600 Only) .....151 Appendix I: SafeCom Messages (D6600 Only) ....158 Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Figure 14: Figure 15: Figure 16: Figure 17: Figure 18: Figure 19: Figure 20: Figure 21: Figure 22: Figure 23: Figure 24: Figure 25: Figure 26: Table 8: Table 9: Figures Figure 1: Table 7: D6600/D6100i System – Standard/Network Automation .................7 D6600 System – Direct Connect ...............7 D6100i System – Direct Connect ..............7 Null Modem Cable Configuration ............8 Straight-through Modem Cable Configuration...............................................8 Modem Cable Pin Definitions ...................8 Message sent to printer.............................28 Message sent to printer.............................29 Message sent to printer.............................30 Message sent to printer.............................31 Message sent to printer.............................32 Message sent to Printer.............................33 Message sent to printer.............................34 Message sent to printer.............................35 Message sent to printer.............................35 Message sent to printer.............................36 Message sent to printer.............................37 Single message sent to Printer..................39 Multiple messages sent to printer ............39 Message sent to printer.............................41 Message sent to printer.............................41 Message sent to printer.............................43 Message sent to printer.............................47 Message sent to printer.............................50 Contact ID format.....................................53 D6200 Receiver Software Line Card Configuration...........................................141 Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Table 16: Table 17: Table 18: Table 19: Table 20: Table 21: Table 22: Table 23: Table 24: Table 25: Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: 4 Recommended Programming Selections..8 D6600 Line Number/Group Number Conversion Table........................................9 Message Type 9 (Acron Super Fast) Byte Description...................................................9 Message Type b (Ademco 4-1 Express) Byte Description........................................10 Message Type c (Ademco 4-2 Express) Byte Description........................................10 Message Type a (Ademco Contact ID) Byte Description........................................11 Table 26: Table 27: Table 28: Table 29: Table 30: Table 31: Message Type f (Ademco High Speed, 4-8-1) Byte Description ............................ 11 ADT SIA (Message Type S) Byte Description ................................................ 12 Caller ID (Message Type e) Byte Description ................................................ 12 CFSK (Message Type i) Byte Description ................................................ 13 Common Formats (Message Type 1) Byte Description ................................................ 13 DNIS/ANI (Message Type N) Byte Description ................................................ 14 DSC-4-3 (Message Type d) Byte Description ................................................ 14 FBI Super Fast (Message Type F) Byte Description ................................................ 15 ITI (Message Type I) Byte Description .. 15 Link Test (Message Type 1) Byte Description ................................................ 16 Robofon (Message Type j) Byte Description ................................................ 16 Sescoa Super Speed (Message Type 7) Byte Description ....................................... 17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description ................................................ 18 Scancom 4-24-1, 5-24-1, 6-24-1 Available Upon Request (Message Type h) Byte Description......................... 19 Seriee FSK (Message Type k) Byte Description ................................................ 20 Seriee DTMF (Message Type l) Byte Description ................................................ 20 SIA (Message Type S) Byte Description ................................................ 21 SIA (Message Type S) Byte Description ................................................ 21 Silent Knight FSK1 (Message Type m) Byte Description ....................................... 22 Optional Silent Knight SK1 (Message Type m) Byte Description........................ 22 Silent Knight Automation Format........... 23 Silent Knight FSK2 (Message Type m) Byte Description ....................................... 24 Silent Knight FSK80 (Message Type E) Byte Description ....................................... 24 Telim (Message Type n) Byte Description ................................................ 25 Text Message (Message Type 3) Byte Description ................................................ 25 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Contents . Table 32: Varitech FSK 4-1 (Message Type 1) Byte Description........................................26 Table 33: Varitech FSK 4-2 (Message Type 1) Byte Description........................................26 Table 34: VONK (Message Type V) Byte Description.................................................27 Table 35: X-SIA Text (Message Type S) Byte Description.................................................27 Table 36: SafeCom (Message Type p) Byte Description.................................................28 Table 37: Acron Super Fast (Message Type 9) Byte Description.................................................28 Table 38: Acron Super Fast (Message Type 9) Printer Output ...........................................28 Table 39: Ademco Contact-ID (Message Type a) Byte Description........................................29 Table 40: Ademco Contact-ID (Message Type a) Printer Output ...........................................29 Table 41: Ademco 4-1 Express (Message Type b) Byte Description........................................30 Table 42: Ademco 4-1 Express (Message Type b) Printer Output ...........................................30 Table 43: Ademco 4-2 Express (Message Type c) Byte Description........................................31 Table 44: Ademco 4-2 Express (Message Type c) Printer Output ...........................................31 Table 45: Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description........................................32 Table 46: Ademco High Speed, 4-8-1 (Message Type f) Printer Output..............................32 Table 47: ADT SIA (Message Type ) Byte Description.................................................33 Table 48: Caller ID (Message Type ) Byte Description.................................................33 Table 49: CFSK (Message Type I) Byte Description.................................................34 Table 50: Common Formats (Message Type ) Byte Description ........................34 Table 51: Common Formats (Message Type ) Byte Description ........................35 Table 52: DNIS/ANI (Message Type N) Byte Description.................................................35 Table 53: DSC 4-3 (Message Type d) Byte Description.................................................36 Table 54: DSC 4-3 (Message Type d) Printer Output ........................................................36 Table 55: Event Code Table .....................................36 Table 56: Printer Output Codes ...............................36 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Table 57: Table 58: Table 59: Table 60: Table 61: Table 62: Table 63: Table 64: Table 65: Table 66: Table 67: Table 68: Table 69: Table 70: Table 71: Table 72: Table 73: Table 74: Table 75: Table 76: Table 77: Table 78: Table 79: Table 80: Table 81: FBI Super Fast (Message Type F) Byte Description ................................................ 37 FBI Super Fast (Message Type F) Printer Output........................................... 37 Event Code Table..................................... 37 Printer Output Codes ............................... 37 ITI (Message Type I) Byte Description .. 38 Link Test (Message Type ) Description ................................................ 38 RB2000 (Message Type R) Byte Description ................................................ 39 RB2000 (Message Type R) Printer Output........................................................ 39 Robofon (Message Type j) Byte Description ................................................ 40 Scancom 4-16-1, 5-16-1, 6-16-1 Available Upon Request (Message Type g) Byte Description ......................... 40 Scancom 4-16-1, 5-16-1, 6-16-1 Available Upon Request (Message Type g) Printer Output............................. 41 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description ................................................ 41 Scancom 4-24-1, 5-24-1, 6-24-1 Available Upon Request (Message Type h) Printer Output ............................ 41 Seriee DTMF (Message Type l) Byte Description ................................................ 42 Seriee FSK (Message Type k) Byte Description ................................................ 42 Sescoa Super Speed (Message Type 7) Byte Description ....................................... 43 Sescoa Super Speed (Message Type 7) Printer Output........................................... 43 Silent Knight FSK0 (Message Type ) Byte Description........................ 44 Silent Knight FSK1 (Message Type m) Byte Description ....................................... 44 Optional Silent Knight FSK1 (Message Type m) Byte Description........................ 45 Silent Knight FSK1 Optional Outputs.... 45 Silent Knight FSK2 (Message Type m) Byte Description ....................................... 46 Silent Knight FSK80 (Message Type E) Byte Description ....................................... 47 Silent Knight FSK80 Printer/LCD output .................................................................... 47 Telim (Message Type n) Byte Description .................................................................... 48 5 Conettix D6600/D6100i | Computer Interface Manual | Contents Table 82: Table 83: Table 84: Table 85: Table 86: Table 87: Table 88: Table 89: Table 90: Table 91: Table 92: Table 93: Table 94: Table 95: Table 96: Table 97: Table 98: Table 99: Table 100: Table 101: Table 102: Table 103: Table 104: Table 105: Table 106: Table 107: Table 108: Table 109: Table 110: Table 111: Table 112: Table 113: Table 114: Table 115: Table 116: 6 Varitech FSK 4-1 (Message Type ) Byte Description ........................48 Varitech FSK 4-2 (Message Type ) Byte Description ........................49 VONK (Message Type V) Byte Description.................................................49 X-SIA text (Message Type ) Byte Description........................................50 X-SIA Printer/LCD output ......................50 SafeCom (Message Type p) Byte Description.................................................51 ASCII Text Message to Automation Port .............................................................52 Input Command Output Messages .........52 Event Codes...............................................53 Internal Messages......................................58 Modem IIIa2 Messages .............................61 Point to Zonex Translation ....................137 User ID to Comex Translation ..............137 Reported Zone/ID to Actual Point/ID ...................................................137 Network Messages...................................138 Pulse 3/1 Format .....................................141 Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 1..............................142 Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 2..............................142 Pulse 3/2...................................................143 Pulse 4/1...................................................143 Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1 ...........................................144 Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2 ...........................................144 Pulse 4/2...................................................145 Pulse 4/3...................................................145 Generic Byte Description .......................146 Generic SIA Byte Description ...............146 Message Examples ..................................147 ADT SIA Report Codes .........................149 RB2000 Messages....................................151 Virtual Line Conversion Table..............158 SafeCom Messages - Line Card or Account Signals .......................................159 SafeCom Messages - Intercepted Control Panel Signals..............................162 Explanation of Automation Output Items (within Message Body only) ........164 Explanation of Printer Output Items.....165 Supported Event Codes..........................166 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 1.0 System Connection . 1.0 System Connection 1.1 Conettix D6680 Ethernet Network Adapter Connection Use the Conettix D6680 Ethernet Network Adapter to connect a manufacturer’s automation software package to the D6600 when the software cannot receive network data (Figure 1). Refer to the Special Conettix D6600 Applications in the Conettix D6600/D6100i Network System Guide (P/N: 4998122712). Figure 1: 1.2 Direct Connection – RS-232 Figure 2 and Figure 3 show a D6600/D6100i System using any manufacturer’s automation software package directly connected to a D6600 or D6100i. Figure 2: D6600 System – Direct Connect D6600/D6100i System – Standard/Network Automation 1 - Automation PC 2 - Connection - Automation PC COM port to D6600 COM3 3 - D6600 Figure 3: 12345678910 11 * Automation PC Connection - PC COM1 to D6680 D6680 Connection - D6680 to hub Hub Connection – D6100i to hub D6100i Connection – D6680 to hub Second D6680 Connection - D6680 to D6600 COM4 D6600 D6100i System – Direct Connect 1 - Automation PC 2 - Connection - Automation PC COM port to D6100i COM3 3 - D6100i For automation packages with network capabilities: The packet format received from the D6600 is the same as for RS-232 reporting, execpt an internet protocol (IP) and user datagram protocol (UDP) header is stamped on the packet as the data transmitted by either standard IP or UDP structure over the network. Automation software can support the network communication easily by calling Socket functions, both provided in Windows and Unix. by using the built-in IP connections (or sockets) available in Windows and Unix. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 7 Conettix D6600/D6100i | Computer Interface Manual | 2.0 Making the Right Connection Each pin of the modem cable is defined in Figure 6. 2.0 Making the Right Connection 2.1 Figure 6: COM3 DB9 Connector 1 The COM3 Port uses a standard DB9 female connector. The suggested connections to the computer are shown in Figure 4 to Figure 6. When connecting data terminal equipment (DTE) together (such as a COM1 port to PC serial port), a null-modem cable must be used. One possible configuration for a null-modem cable is shown in Figure 4. Figure 4: Null Modem Cable Configuration DTE DB-9 Pin DTE DB-9 Pin 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 When connecting data terminal equipment to data communication equipment (DCE) (such as the D6600/D6100i COM port to a modem), a modem cable should be used (such as a straight-through cable shown in Figure 5). Figure 5: 8 DCE 1 8 2 3 3 2 4 20 5 7 6 6 7 4 8 5 9 22 2 6 1 - Data carrier detect (DCD) 2 - Receive (RX) 3 - Transmit (TX) 4 - Data terminal ready (DTR) 5 - Signal-ground (SIG-GND) 2.2 3 7 4 8 5 9 6 - Data set ready (DSR) 7 - Ready to send (RTS) 8 - Clear to send (CTS) 9 - Ring indicator (RI) Selecting Program Options in the D6600/D6100i Use the D6600/D6100i keypad or the D6200 Programming Software to program the receivers. Below are the recommended selections for programming when connecting the receivers to an automation system. Additional selections can be found in the D6600/D6100i Program Entry Guide (P/N: 4998122702). Table 1: Receiver Gateway Number Output Format Straight-through Modem Cable Configuration DTE Modem Cable Pin Definitions Baud Rate Link Test Recommended Programming Selections Selects a number (01 to 99) that is included in every message to the computer in both D6500 and SIA modes Enable computer output messages in the selected format: SIA computer interface standard format, recommended (expanded reporting capabilities) D6500 21-character format output Use maximum speed supported by PC Tests if a supervision signal can be sent and received from the central station by the receiver Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.0 Computer Communication Protocols 3.1 D6500 Mode Messages In D6500 Mode, the line number/group number sent to the computer is only one digit. Refer to Table 2. Table 2: D6600 Line Number/Group Number Conversion Table Line# /Group # L01/G01 L02/G02 L03/G03 L04/G04 L05/G05 L06/G06 L07/G07 L08/G08 Converted to 1 2 3 4 5 6 7 8 Line# /Group # L09/G09 L10/G10 L11/G11 L12/G12 L13/G13 L14/G14 L15/G15 L16/G16 Converted to 9 A B C D E F G Line # /Group # L17/G17 L18/G18 L19/G19 L20/G20 L21/G21 L22/G22 L23/G23 L24/G24 Converted to H I J K L M N O Line # /Group # L25/G25 L26/G26 L27/G27 L28/G28 L29/G29 L30/G30 L31/G31 L32/G32 Converted to P Q R S T U V W In D6500 mode, any group that equals 33 is converted to an “X.” Any group greater than or equal to 34 is converted to a “Y.” For lines that are grouped, Gxx appears instead of Lxx. For networked accounts, Nxx appears instead of Lxx and the line number is identified. 3.1.1 Acron Super Fast (Message Type 9) Acron Super Fast Example Table 3: # 1 2 3-4 5 6-9 10-13 14-21 22 D6500 Byte Description 1 h 2 9 3 r 4 r 5 l 6 s 7 s 8 s 9 s 10 a 11 a 12 a 13 a 14 C 15 C 16 C 17 C 18 C 19 C 20 C 21 C 22 t Message Type 9 (Acron Super Fast) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Channels Trailer Character Description Optional. Check with the computer automation software for compatibility. 9 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. Channels 1 to 8 Typically, this is HEX 14. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 9 Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.1.2 Ademco 4-1 Express (Message Type b) 4-1 Express Example Table 4: # 1 2 3-4 5 6-11 12-15 16 17 18-20 21 22 3.1.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h b r r l s s s s s s a a a a s E s s s X t Message Type b (Ademco 4-1 Express) Byte Description Description Optional. Check with the computer automation software for compatibility. b Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event Code, “A” as the default. Three spaces. Zone number. Typically, this is HEX 14. Ademco 4-2 Express (Message Type c) Table 5: 10 D6500 Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces X Trailer Character 4-2 Express Example # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 22 Computer Communication Protocols D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h c r r l s s s s s s a a a a s E s s X Y t Message Type c (Ademco 4-2 Express) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces XY Trailer Character Description Optional. Check with the computer automation software for compatibility. c Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event Code, “A” as the default. Two spaces. Event code and zone number. Typically, this is HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.1.4 Ademco Contact-ID (Message Type a) Contact ID Example Table 6: D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h a r r l s a a a a 1 8 Q X Y Z G G C C C t Message Type a (Ademco Contact ID) Byte Description # 1 2 3-4 5 6 7-10 11-12 13 14-16 17-18 19-21 22 3.1.5 Computer Communication Protocols Title Header Character (h) Message Type Receiver Number Line/Group Number Space Account Number 18 Qualifier XYZ GG CCC Trailer Character Description Optional. Check with the computer automation software for compatibility. a Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Account number, four digits. Ademco Contact-ID format number Qualifier, 1=New event or opening, 3=New restore or closing, 6=Previous event. Class code and event code (see Appendix A). Group number. Zone codes or user ID. Typically, this is HEX 14. Ademco High Speed, 4-8-1 (Message Type f) SCANCOM 4-8-1, 5-8-1, 6-8-1 - Available Upon Request High Speed Example Table 7: D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 h f r r l a a a a a a s C C C C s C C C C s C t Message Type f (Ademco High Speed, 4-8-1) Byte Description # 1 2 3-4 5 6-11 Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number 12 13-16 17 18-21 22 23 24 Space CCCC Space CCCC Space C Trailer Character Description Optional. Check with the computer automation software for compatibility. f Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number, up to six digits. Account number less than six characters is right aligned with leading ASCII spaces. One space. Channels 1 to 4. One space. Channels 5 to 8. One space. Supervisory channel. Typically, this is HEX 14. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 11 Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.1.6 ADT SIA (Message Type S) ADT SIA Example Table 8: # 1 2 3-4 5 6 7 8-11 12 13-32 33 34-35 36-39 40 41 42 3.1.7 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 h S r r l [ # a a a a | d a m m - d d - y 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 y t I h h : m m : s s E M M Z Z Z Z / ** * t ADT SIA (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number space # Account Number | Date and Time E Event Code Zone / *** Trailer Character Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. # Up to sixteen digits in the account number. Separator. Indicates more data positions after account number. Date and time. SIA block code. SIA event code (refer to Appendix G ADT SIA Report Codes on page 149). Zone number. Separator. Next block of data. Typically, this is HEX 14. Caller ID (Message Type e) Caller ID Example Table 9: D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h e r r 1 T T T T T T T T T T T T T T T T t Caller ID (Message Type e) Byte Description # 1 2 3-4 5 6-21 Title Header Character (h) Message Type Receiver Number Line/Group Number Caller ID 22 Trailer Character 12 Computer Communication Protocols Description Optional. Check with the computer automation software for compatibility. e Receiver gateway Number from 01 to 99. Line number in the receiver gateway that sent the message. Up to sixteen digits, Caller ID with less than sixteen characters is right aligned with leading ASCII spaces. Typically, this is HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.1.8 CFSK (Message Type i) CFSK Example Table 10: # 1 2 3-4 5 6-9 10-15 16-17 18-19 20-21 22 3.1.9 Computer Communication Protocols D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h i r r l s s s s a a a a a a T T E E s s t CFSK (Message Type i) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number TT EE Spaces Trailer Character Description Optional. Check with the computer automation software for compatibility. i Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Four spaces. Six digit account number. Event Code. Zone/User ID. Two spaces. Typically, this is HEX 14. Common Formats (Message Type 1) Type 1 Example Table 11: D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h l r r l a a a a a a a a a a E E y y y y t Common Formats (Message Type 1) Byte Description # 1 2 3-4 5 6-15 Title Header Character (h) Message Type Receiver Number Line Number Account Number 16-17 Event Code 18-21 Zone Number 22 Trailer Character Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number, up to ten digits. Account numbers less than ten characters are right aligned with leading ASCII spaces. Event codes define the type of signal received and interpreted by the D6500 receiver gateway. Zone or ID number sent by the communicator. Zone numbers less than four digits are right aligned with leading ASCII spaces. Typically, this is HEX 14. The receiver gateway will sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the programmable option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 13 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.1.10 DNIS/ANI (Message Type N) DNIS/ANI Example Table 12: # 1 2 3-4 5 6 7 8-18 19 20-30 31 D6500 Byte Description 1 H 2 N 3 r 4 r 5 l 6 s 7 D 8 d 9 d 10 d 11 d 12 d 13 d 14 d 15 d 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 d d & a a a a a a a a a 16 DNIS/ANI (Message Type N) Byte Description Title Header Character (H) Message Type Receiver Number Line/Group Number Space DNIS Identifier DNIS Number ANI Identifier (&) ANI Number Trailer Character Description Optional. Check with the computer automation software for compatibility. N (Capital n). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. DNIS identifier. DNIS number, up to 11 digits. ANI identifier. ANI number, up to 11 digits. Typically, this is HEX 14. 3.1.11 DSC 4-3 (Message Type d) DSC 4-3 Example Table 13: # 1 2 3-4 5 6-11 12-15 16 17 18 19 20-21 22 14 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h d r r l s s s s s s a a a a s E s X Y Y t DSC-4-3 (Message Type d) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Space X YY Trailer Character Description Optional. Check with the computer automation software for compatibility. d Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event Code, “A” as the default. One space. Event code number. Zone number. Typically, this is HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.1.12 FBI Super Fast (Message Type F) FBI Super Fast Example Table 14: # 1 2 3-4 5 6-11 12-15 16 17-18 19 20-21 22 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h F r r l s s s s s s a a a a T Z Z E s s t FBI Super Fast (Message Type F) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number T ZZ E Spaces Trailer Character Description Optional. Check with the computer automation software for compatibility. F (Capital f). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. Zone type. Zone number. Event type. Two spaces. Typically, this is HEX 14. 3.1.13 ITI (Message Type I) ITI Example Table 15: # 1 2 3-4 5 6-8 9 10 11-14 15 16 17-18 19 20 21 22 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h I r r l s s s a T a a a a G I Z Z E W N t ITI (Message Type I) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Panel Type Account Number G I ZZ E W N Trailer Character Description Optional. Check with the computer automation software for compatibility. I (Capital i). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Three spaces. First digit account number. Control panel Type. Next four digit account number. Group number. Open/close (O/C) User ID. Zone number. Condition code. Protection level was. Protection level is. Typically, this is HEX 14. 3.1.14 Link Test (Message Type 1) Link Test Example D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h 1 r r 0 s s s s s s s s s s s @ s s s s t The D6600/D6100 can automatically generate this message at the programmed intervals. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 15 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Table 16: # 1 2 3-4 5 6-15 16-17 18-21 22 Computer Communication Protocols Link Test (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line Number Spaces Event Code Spaces Trailer Character Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number as zero for link test. Eleven spaces. Event code is @ for link test. Four spaces. Typically, this is HEX 14. 3.1.15 Robofon (Message Type j) Robofon Example Table 17: # 1 2 3-4 5 6-9 10-15 16-17 18-21 22 16 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h j r r l s s s s a a a a a a E E s s s s t Robofon (Message Type j) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number EE Spaces Trailer Character Description Optional. Check with the computer automation software for compatibility. j Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Four spaces. Six digit account number. Event code. Four spaces. Typically, this is HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.1.16 Sescoa Super Speed (Message Type 7) Sescoa Super Speed Example Table 18: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20 21 22 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h 7 r r l s s s s s s a a a a s I A A C s t Sescoa Super Speed (Message Type 7) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space I AA C s Trailer Character Description Optional. Check with the computer automation software for compatibility. 7 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Account number, four digits. One space. Event code. Two digit zone code or the first two digits user code. Space if zone report, or the last digit user code. One space. Typically, this is HEX 14. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 17 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.1.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Scancom 4-16-1, 5-16-1, 6-16-1 Example Table 19: D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 h g r r l a a a a a a s C C C C s 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 C C C C s C C C C s C C C C s C t Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description # 1 2 3-4 5 6-11 Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number 12 13-16 17 18-21 22 23-26 27 28-31 32 33 34 Space CCCC Space CCCC Space CCCC Space CCCC Space C Trailer Character 18 Description Optional. Check with the computer automation software for compatibility. g Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number up to six digits. Account numbers less than six characters are right aligned with leading ASCII spaces. One space. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Supervisory channel. Typically, this is HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.1.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Scancom 4-24-1 Example Table 20: D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h h r r l a a a a a a s C C C C s C C C C 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 C C C C s C C C C s C C C C s C C C C s C s t Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description # 1 2 3-4 5 6-11 Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number 12 13-16 17 18-21 22 23-26 27 28-31 32 33-36 37 38-41 42 43 44 Space CCCC Space CCCC Space CCCC Space CCCC Space CCCC Space CCCC Space C Trailer Character Description Optional. Check with the computer automation software for compatibility. h Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Account number up to six digits. Account numbers less than six characters are right aligned with leading ASCII spaces. One space. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Channels 17 to 20. One space. Channels 21 to 24. One space. Supervisory channel. Typically, this is HEX 14. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 19 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.1.19 Seriee FSK (Message Type k) Seriee FSK Example D6500 Byte Description Table 21: # 1 2 3-4 5 6-11 12-16 17 18 19 20 -21 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h k r r l s s s s s s a a a a a s E s Z Z t 20 21 22 Seriee FSK (Message Type k) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Space ZZ Trailer Character Description Optional. Check with the computer automation software for compatibility. k Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Five digit account number. One space. Event code. One space. Zone number. Typically, HEX 14. 3.1.20 Seriee DTMF (Message Type l) Seriee DTMF Example Table 22: # 1 2 3-4 5 6-7 8 9-14 15 16-21 22 20 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 h l r r l L L * a a a a a a * 16 17 18 19 . . . t Seriee DTMF (Message Type l) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number LL * Account number * *** Trailer Character Description Optional. Check with the computer automation software for compatibility. 1 (lowercase L). Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Data length. Data separator. Four, five or six account numbers. Data separator. DTMF Seriee Data. Typically, HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.1.21 SIA (Message Type S) Defined Messages SIA Example D6500 Byte Description Table 23: # 1 2 3-4 5 6 7 8-11 12 13 14-15 16-19 20 21 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 h S r r l [ # a a a a | E M M Z Z Z Z / ***] 21 22 t SIA (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number [ # Account Number | E Event Code Zone / ***] Trailer Character Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Open bracket. # Up to sixteen digits may be used in the account number. Separator, indicates more data positions after account number. SIA block code. SIA Event code. Zone number. Separator. Next block of data. Typically, HEX 14. Undefined Messages When an SIA message contains unprintable characters (unprintable characters are out of ASCII range 0x32-0x7E) or without an account block: SIA Example Table 24: # 1 D6500 Byte Description 1 2 3 4 5 6 h S r r L [ . . . data N-1 N ] t SIA (Message Type S) Byte Description 6 7-(N-2) Title Header Character (h) Message Type Receiver Number Line/Group Number [ data N Trailer Character 2 3-4 5 7 Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Open bracket. The received SIA message contains hex characters either with or without account portion. Typically, HEX 14. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 21 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.1.22 Silent Knight FSK0 (Message Type 1) Silent Knight FSK0 Example Table 25: # 1 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h 1 r r l s s s s s s a a a a s E s s s Z 20 21 22 Silent Knight FSK1 (Message Type m) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Spaces E Space Zone number Trailer Character 2 3-4 5 6-11 12-15 16 17 18-20 21 22 t Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Four digit account number. One space. Event code. Three spaces. Zone number. Typically, HEX 14. Optional Silent Knight SK1 (Message Type m): If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to 1, the following output is used. Silent Knight FSK1 Example D6500 Byte Description 1 h Table 26: # 1 2 m 3 r 6 7-14 15 16-17 18 19 21 “ ZZ “ *** Trailer Character 22 5 l 6 s 7 a 8 a 9 a 10 11 12 13 14 15 16 17 18 a a a a a “ Z Z “ 19 . . . t Optional Silent Knight SK1 (Message Type m) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number 2 3-4 5 4 r Description Optional. Check with the computer automation software for compatibility. m Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Maximum eight-digit account code. If the account code is less than eight digits, enter the actual number of digits without a leading space. Separator. First zone number, up to eight reports, one report has two digits. Separator. More data. Typically, HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . Table 27: Silent Knight Automation Format Report Code Description 00: 01 to 08: 09: 10 to 19: 20 to 29: 30: 31: 32: 33: 34: 35: 36: 37: 38: 39: 40: 41 to 49: 50 to 59: 60: 61 to 68: 69: 70: 71 to 78: 79: 80: 81 to 89: 90: 91 to 99: Alarm Panic Alarm 01 to 08 Holdup Alarm 10 to 19 Alarm Restore 10 to 19 Test Code Trouble Line 1 Trouble Line 2 Expand Trouble Forced Access Restore Line 1 Restore Line 2 Expand Restore Cancel Code Data Lost Closing Closing 01 to 09 Bypass 10 to 19 Trouble AC Trouble 01 to 08 Trouble BAT Restore AC Restore 01 to 08 Restore BAT Access Access 01 to 09 Opening Opening 01 to 09 To Automation 2 5 16=0(EEZZ) PAss sA0x Hass sA1x sH1x sXss LT01 LT02 ETss DFss LR01 LR02 ERss OCss RTss CL00 CL0x sB1x ATss sT0x YTss ARss sRss YRss DS00 DG0x OP00 OP0x Bosch Security Systems, Inc. | 9/07 | 4998122703-02 2 5 16=1(ZZ) 00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 80 to 89 90 91 to 99 Note x=1 to 8 x=0 to 9 x=0 to 9 x=1 to 9 x=0 to 9 x=1 to 8 x=1 to 9 23 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.1.23 Silent Knight FSK2 (Message Type m) Silent Knight FSK2 Example Table 28: # 1 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h m r r l s a a a a a a a a “ E E Z Z “ * * * Silent Knight FSK2 (Message Type m) Byte Description 6 7-14 Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number 15 16-19 “ EEZZ 20 21 22 “ *** Trailer Character 2 3-4 5 t Description Optional. Check with the computer automation software for compatibility. m Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Maximum eight-digit account code. If the account code is less than eight digits, enter the actual number of digits without a leading space. Separator. First event and zone number. If this is the only event, it will be ended with the terminator. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, two-digit zone code. Separator. Next data. Typically, HEX 14. 3.1.24 Silent Knight FSK80 D6500 mode (Message Type E) Silent Knight FSK80 Example Table 29: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 24 24 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h E r r l s s s s s s A A A A s A s s X Y t Silent Knight FSK80 (Message Type E) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space Filler character A Spaces XY Trailer Character Description Optional. Check with the computer automation software for compatibility. E Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Four-digit account number. Always char “A”. Two-digit alarm zone code. Typically, HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.1.25 Telim (Message Type n) Telim Example Table 30: # 1 2 3-4 5 6 7-12 13 14 15-32 33 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 h n R R L s A A A A A A s E T T Z 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z t Z Telim (Message Type n) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Space Account Number Space E TTZZZZZZZZZZZZ Trailer Character Description Optional. Check with the computer automation software for compatibility. n Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. One space. Six digit account number. One space. Event code. Input line number. Typically, HEX 14. 3.1.26 Text Message (Message Type 3) Type 3 Example Table 31: # 1 2 3-4 5 6-21 22 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 h 3 r r l P R I N T E R 13 14 15 16 17 18 19 20 21 22 v v . v v t Text Message (Message Type 3) Byte Description Title Header Character (h) Message Type Receiver Number Line Number Message Text Trailer Character Description Optional. Check with the computer automation software for compatibility. 3 Receiver gateway number from 01 to 99. Line number fixed at 1. Sixteen characters in length. Typically, HEX 14. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 25 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.1.27 Varitech FSK 4-1 (Message Type 1) Varitech FSK 4-1 D6500 Byte Description Example 1 2 3 4 5 6 h Table 32: # 1 2 3-4 5 6-11 12-15 16 17 18-20 21 22 1 r r l s 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 s s s s s a a a a s E s s s X t Varitech FSK 4-1 (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces X Trailer Character Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Four digit account number. One space. Event code. Three spaces. Zone number. Typically, HEX 14. 3.1.28 Varitech FSK 4-2 (Message Type 1) Varitech FSK 4-2 D6500 Byte Description Example 1 2 3 4 5 6 h Table 33: # 1 2 3-4 5 6-11 12-15 16 17 18-19 20-21 22 26 1 r r l s 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 s s s s s a a a a s E s s X Y t Varitech FSK 4-2 (Message Type 1) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number Spaces Account Number Space E Spaces XY Trailer Character Description Optional. Check with the computer automation software for compatibility. 1 Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Six spaces. Four digit account number. One space. Event code. Two spaces. Zone number. Typically, HEX 14. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.1.29 VONK (Message Type V) D6500 Byte Description 1 2 3 4 5 6 h V r r l A VONK Example Table 34: # 1 8 1 9 2 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 3 4 5 6 7 8 9 A B C D E F G t VONK (Message Type V) Byte Description 6-7 8-23 Title Header Character (h) Message Type Receiver Number Line/Group Number Account Number Zone status 24 Trailer Character 2 3-4 5 7 A Description Optional. Check with the computer automation software for compatibility. V Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Two digit account number. Status of zones 1 to 16. If the zone is Closed, a “.”(Period) is in this position. If the zone is Open, 1 to G appears in this position. Typically, HEX 14 3.1.30 X-SIA Text (Message Type S) X-SIA Example Table 35: # 1 2 3-4 5 6 7 8-11 12 13 14-15 16-19 20 21 22-34 35 36-37 38 39-41 42 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h S r r l [ # a a a a | E M M Z Z Z Z * ` 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 T T T T T T T T T T T T ‘ N M / * * * t T X-SIA Text (Message Type S) Byte Description Title Header Character (h) Message Type Receiver Number Line/Group Number [ # Account Number | E MM ZZZZ * ‘ TT…T ‘ NM / *** Trailer Character Description Optional. Check with the computer automation software for compatibility. S Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Open bracket. # Use up to sixteen digits in the account number. Separator. Indicates more data positions after account number. SIA block code. SIA event code. Zone number. Text identifier. Quotation mark (single). 13 character text string. Qutotation mark (single). Unit field characters. Separator. Next block of data. Typically, HEX 14. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 27 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.1.31 SafeCom (Message Type p) SafeCom Example Table 36: # 1 2 3-4 5 6-9 10-13 14-(N-1) N 3.2 D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 h p r r l A A A A E E E E 14 ... N-1 . . . data . . . N t SafeCom (Message Type p) Byte Description Title Header Character (h) Message Type Receiver Number Line Card Number Account Number Event Code Data Trailer Character Description Optional. Check with the computer automation software for compatibility. p Receiver gateway number from 01 to 99. Line number in the receiver gateway that sent the message. Four digits. Four digits. Parameter data for event code. Typically, HEX 14. SIA Mode Messages Use the SIA mode for central station monitoring. 3.2.1 Acron Super Fast (Message Type 9) Acron Super Fast Example Table 37: Acron Super Fast (Message Type 9) Byte Description Title L CRC Message Type sequence# receiver# line# (Line/Group #) account# Figure 7: SIA Mode Description <9>[#aaaa|CCCCCCCC] Description Standard line feed character. Cyclical redundancy check number. 9 The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Message sent to printer Table 38: Acron Super Fast (Message Type 9) Printer Output mm/ddshh:mmsLxxsACNsACCTsaaaa +++sACCTsaaaasCCCCsCCCC For lines that are grouped, Gxx appears instead of Lxx. 28 Characters ACN Lxx Gxx Description Acron Super Fast format. Line number. Grouped line numbers. Bosch Security Systems, Inc. | 8/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.2.2 Computer Communication Protocols Ademco Contact-ID (Message Type a) Contact-ID Example Table 39: SIA Mode Description [#aaaa|18QXYZGGCCC] Ademco Contact-ID (Message Type a) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# 18 Q XYZ GG CCC Figure 8: Description Standard line feed character. Cyclical redundancy check number. a The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Ademco Contact-ID format number. Qualifier, 1 = New event or opening, 3 = New restore or closing, 6 = Previous event. Class code and event code (refer to Appendix A: Contact ID Event Code Classifications on page 53). Group number. Zone codes or User ID. Message sent to printer Table 40: Ademco Contact-ID (Message Type a) Printer Output mm/ddshh:mmsLxxsCIDsACCTsaaaa +++sACCTsaaaasNNNsEVENT=XYZsG=GGsC=CCC For lines that are grouped, Gxx appears instead of Lxx. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Characters CID Gxx Lxx NNN Description Contact-ID format. Grouped Line numbers. Line number. If Q = 1, print E/O for new event or opening If Q = 3, print R/C for restore or closing If Q = 6, print “OLD” for old messages and events. 29 Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.2.3 Computer Communication Protocols Ademco 4-1 Express (Message Type b) 4-1 Express Example Table 41: SIA Mode Description [#aaaa|X] Ademco 4-1 Express (Message Type b) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# X Figure 9: Description Standard line feed character. Cyclical redundancy check number. b The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Zone number Message sent to printer mm/ddshh:mmsLxxsE41sACCTsaaaasEVENT=X For lines that are grouped, Gxx appears instead of Lxx. Table 42: Characters E41 Lxx: Gxx 30 Ademco 4-1 Express (Message Type b) Printer Output Description Ademco 4-1 Express format. Line number. Grouped line numbers. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.2.4 Ademco 4-2 Express (Message Type c) 4-2 Express Example Table 43: SIA Mode Description [#aaaa|XY] Ademco 4-2 Express (Message Type c) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# XY Description Standard line feed character. Cyclical redundancy check number. c The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code and Zone number. Figure 10: Message sent to printer mm/ddshh:mmsLxxsE42sACCTsaaaasEVENT=XY For lines that are grouped, Gxx appears instead of Lxx. Table 44: Characters E42 Lxx: Gxx Ademco 4-2 Express (Message Type c) Printer Output Description Ademco 4-2 Express format. Line number. Grouped line numbers. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 31 Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.2.5 Computer Communication Protocols Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) SCANCOM 5-8-1, 6-8-1 - available upon request High Speed Example Table 45: SIA Mode Description [#aaaaaa|CC CCsCCCCsC] Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# CCCC s CCCC s C Description Standard line feed character. Cyclical redundancy check number. f The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Channels 1 to 4. One space. Channels 5 to 8. One space. Supervisory channel. Figure 11: Message sent to printer Table 46: Ademco High Speed, 4-8-1 (Message Type f) Printer Output mm/ddshh:mmsLxxsHGHsACCTsaaaaaa +++sACCTsaaaaaasCCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx. 32 Characters HGH Lxx: Gxx Description Ademco High Speed format. Line number. Grouped line numbers. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 . 3.2.6 ADT SIA (Message Type ) ADT SIA Example Table 47: SIA Mode Description [#aaaa|data] ADT SIA (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# E damm-dd-yytihh:mm:ss Data 3.2.7 Computer Communication Protocols Description Standard line feed character. Cyclical redundancy check number. 09 hex . The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number up to sixteen digits. Event Code (refer to Appendix G ADT SIA Report Codes on page 149). Date and time. This field contains message data codes such as event type, area number, point number, identification number. Caller ID (Message Type ) SIA Example Table 48: SIA Mode Description [&TTTTTTTTTTTTTTTT] Caller ID (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) & T Description Standard line feed character. Cyclical Redundancy Check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. Origin ID Block. Up to 16-digit Caller ID. Figure 12: Message sent to Printer [#0000 | &TTTTTTTTTTTTTTTT] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 33 Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.2.8 CFSK (Message Type I) CFSK Example Table 49: SIA Mode Description [#aaaaaa|TTEE] CFSK (Message Type I) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # TT EE 3.2.9 Computer Communication Protocols Description Standard line feed character. Cyclical redundancy check number. I (Capital I). The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, up to six digits. Event code. Zone/User ID. Common Formats (Message Type ) Defined Messages SIA Example Table 50: SIA Mode Description [#aaaaaaaaaaaaaaaa|data] Common Formats (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# Data Description Standard line feed character. Cyclical Redundancy Check number. 09 hex The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number up to sixteen digits. This field contains message data codes such as event type, area number, point number, identification number, and so on. The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats, BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the program option selected. The receiver gateway also sends internal and Modem IIIa² messages in either D6500 mode or SIA mode, depending on the programmable option selected. Refer to Appendix B: Internal Messages on page 58 and Appendix C: Modem IIIa2 Messages on page 61 for a list of the messages and their descriptions. Figure 13: Message sent to printer MM/DDsHH:MMsLxxSIA ACCT aaaa +++ TEXT 1 +++ TEXT 2 34 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . Undefined Messages When a common format message contains unprintable hex characters (unprintable characters are out of ASCII range 0x32-0x7E) or without an account block: SIA Example SIA Mode Description [data] Table 51: Common Formats (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver# Description Standard line feed character. Cyclical Redundancy Check number. 09 hex. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100i. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The D6600/D6100i uses Line 0 (zero) for receiver gateway messages. The receiver message contains hex characters either with or without account portion. line# (Line/Group #) Data Figure 14: Message sent to printer MM/DDsHH:MMsLxx[SIA] +++ TEXT 1 +++ TEXT 2 3.2.10 DNIS/ANI (Message Type N) SIA Example Table 52: SIA Mode Description [#0000|Dddddddddddd&aaaaaaaaaa] DNIS/ANI (Message Type N) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# D DNIS number (d) ANI identifier (&) ANI number (a) Description Standard line feed character. Cyclical redundancy check number. N The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. Fixed at 0000. DNIS identified. DNIS number, up to 11 digits. ANI identifier. ANI number, up to 11 digit.s Figure 15: Message sent to printer MM/DDsHH:MMsLxxsDNISsddddddddddd +++sANIsaaaaaaaaaaa Bosch Security Systems, Inc. | 9/07 | 4998122703-02 35 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.2.11 DSC 4-3 (Message Type d) DSC4-3 Example Table 53: SIA Mode Description [#aaaa|XYY] DSC 4-3 (Message Type d) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# X YY Description Standard line feed character. Cyclical redundancy check number. d The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code number. Zone number. Figure 16: Message sent to printer Table 54: DSC 4-3 (Message Type d) Printer Output mm/ddshh:mmsLxxsDSGsACCTsaaaasEVENT=XYY +++sACCsaaaaseeeeeeeesiisnnn For lines that are grouped, Gxx appears instead of Lxx. Table 55: Event Code Table Code Number Message 1 2 3 4 5 6 7 8 9 0 B C D E F Alarm 36 Close Open Alarm Restore Trouble CloseGrp OpenGrp Bypass UnBypass Cancel Characters DSG Lxx: Gxx Table 56: Event Characters A A A C O A A A R T C O B H O Characters ii nnn eeeeeeee Description DSC/Sur-Gard 4-3 format. Line number. Grouped line numbers. Printer Output Codes Description ZN=Zone number - ID=User ID Zone/User number. Up to eight-character event type, right justified – ALARM, RESTORE, TROUBLE, OPEN, OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.2.12 FBI Super Fast (Message Type F) FBI Super Fast Example Table 57: SIA Mode Description [#aaaa|TZZE] FBI Super Fast (Message Type F) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# T ZZ E Description Standard line feed character. Cyclical redundancy check number. F The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Zone type. Zone number. Event type. Figure 17: Message sent to printer Table 58: mm/ddshh:mmsLxxsFBIsACCTsaaaasETsnnn +++sACCTsaaaastttttttttseeeeeeeesZNsnnn For lines that are grouped, Gxx appears instead of Lxx. Table 59: Code 1 2 3 4 5 6 7 8 9 0 B C D E F Event Code Table Zone/Event Type Fire Panic Burglary Medical Auxiliary Bypass Inactive Eight Nine Zero Opening Closing Abort Restore Trouble Bosch Security Systems, Inc. | 9/07 | 4998122703-02 FBI Super Fast (Message Type F) Printer Output Characters FBI Lxx: Gxx Description FBI Super Fast format. Line number. Grouped line numbers. Table 60: Printer Output Codes Characters ZN nnn ttttttttt eeeeeeee Description ZN=Zone number - ID=User ID Zone/User number. Up to nine-character zone type, right justified FIRE, PANIC, BURGLARY, MEDICAL, AUXILIARY. Up to eight-character event type, left justified ALARM, RESTORE, TROUBLE, OPEN, OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL. 37 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.2.13 ITI (Message Type I) ITI Example Table 61: SIA Mode Description [#aaaaa|GIZZEWN] ITI (Message Type I) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# G I ZZ E W N Description Standard line feed character. Cyclical redundancy check number. I (Captial I). The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Group number. O/C User ID. Zone number. Condition code. Protection level was. Protection level now. 3.2.14 Link Test (Message Type ) Link Test Example SIA Mode Description [] The D6600/D6100 can automatically generate this message at the preprogrammed intervals. Table 62: Link Test (Message Type ) Description Title LF CRC Message Type sequence# receiver# 38 Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for the D6600/D6100. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.2.15 RB2000 (Message Type R) Description RB2000 Example Table 63: SIA Mode Description [] RB2000 (Message Type R) Byte Description Title LF CRC R sequence# Receiver# line# CR Description Standard line feed character, hex 0A. Cyclical redundancy check number. ASCII R, Message Type R for RB2000 format. The message sequence number. The valid sequence number range: 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for the D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. VDS message sent as a hex string, the receiver extracts the alarm type. Hex 0D Figure 18: Single message sent to Printer Table 64: RB2000 (Message Type R) Printer Output MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ RB2000_EVENT_RAW_DATA Figure 19: Multiple messages sent to printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ RB2000_EVENT_RAW_DATA 1 +++ RB2000_EVENT_RAW_DATA 2 ... +++ RB2000_EVENT_RAW_DATA n Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Characters Description MM/DDsHH:MM RB2 Lxx ACCT xxxxxxxxxxxx Date and time. RB2000 format. Line number. Subscriber number, up to 12 characters(hex). The raw data of RB2000 event. RB2000_EVENT_RAW _DATA RB2000_EVENT_RAW _DATA1 RB2000_EVENT_RAW _DATA 2 RB2000_EVENT_RAW _DATA n The raw data of RB2000 event 1. The raw data of RB2000 event 2. The raw data of RB2000 event n. 39 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.2.16 Robofon (Message Type j) Robofon Example Table 65: SIA Mode Description [#aaaaaa|EE] Robofon (Message Type j) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EE Description Standard line feed character. Cyclical redundancy check number. j The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Event code. 3.2.17 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) 4-16-1 Example Table 66: Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) Account# CCCC s CCCC s CCCC s CCCC s C 40 SIA Mode Description [#aaaaaa|CCCCsCCCCsCCCCsCCCCsC] Description Standard line feed character. Cyclical redundancy check number. g The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Supervisory channel. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . Figure 20: Message sent to printer Table 67: mm/ddshh:mmsLxxsSCNsACCTsaaaaaa +++sACCTsaaaaaasCCCCsCCCCsCCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx. Scancom 4-16-1, 5-16-1, 6-16-1 Available Upon Request (Message Type g) Printer Output Characters SCN Lxx: Gxx Description Scancom. Line number. Grouped line numbers. 3.2.18 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) 4-24-1 Example Table 68: SIA Mode Description [#aaaaaa|CCCCsCCCCs CCCCs CCCCsCCCCsCCCCsC] Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# CCCC s CCCC s CCCC s CCCC s CCCC s CCCC s C Description Standard line feed character. Cyclical redundancy check number. h The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, up to six digits. Channels 1 to 4. One space. Channels 5 to 8. One space. Channels 9 to 12. One space. Channels 13 to 16. One space. Channels 17 to 20. One space. Channels 21 to 24. One space. Supervisory channel. Figure 21: Message sent to printer Table 69: mm/ddshh:mmsLxxsSCNsACCTsaaaaaa +++sACCTsaaaasCCCCsCCCCsCCCCsCCCC ++++++++++++++CCCCsCCCCsC For lines that are grouped, Gxx appears instead of Lxx. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Characters SCN Lxx: Gxx Scancom 4-24-1, 5-24-1, 6-24-1 Available Upon Request (Message Type h) Printer Output Description Scancom. Line number. Grouped line numbers. 41 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.2.19 Seriee DTMF (Message Type l) Seriee DTMF Example Table 70: SIA Mode Description [#aaaa|*data] Seriee DTMF (Message Type l) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # * Data Description Standard line feed character. Cyclical redundancy check number. l (lowercase L). The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Data separator. DTMF Seriee Data. 3.2.20 Seriee FSK (Message Type k) Seriee FSK Example Table 71: SIA Mode Description [#aaaaa|EZZ] Seriee FSK (Message Type k) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) Account # E ZZ 42 Description Standard line feed character. Cyclical redundancy check number. k The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Event code. Zone number. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.2.21 Sescoa Super Speed (Message Type 7) Sescoa Super Speed Example Table 72: SIA Mode Description Sescoa Super Speed (Message Type 7) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# I AA C Description Standard line feed character. Cyclical redundancy check number. 7 The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits are 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code. Two- digit zone code or the first two digits user code. Space if zone report, or the last digit user code. Figure 22: Message sent to printer Table 73: Sescoa Super Speed (Message Type 7) Printer Output mm/ddshh:mmsLxxSESsACCTsaaaa +++sACCTsaaaasEEEseeeeeeeeeeeeee For lines that are grouped, Gxx appears instead of Lxx. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Characters SES Lxx Gxx aaaa EEE eeeeeeeeeeeeee Description SESCOA Super Speed format. Line number. Grouped line numbers. Account code. SESCOA Super Speed format event. Up to 14-characters of event description. 43 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.2.22 Silent Knight FSK() (Message Type ) Silent Knight FSK0 Example Table 74: SIA Mode Description [#aaaa|data] Silent Knight FSK0 (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # Data Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Data. 3.2.23 Silent Knight FSK1 (Message Type m) Silent Knight FSK1 Example Table 75: SIA Mode Description [#aaaa| EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ] Silent Knight FSK1 (Message Type m) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EEZZ”EEZZ”EEZZ”EEZZ” EEZZ”EEZZ”EEZZ”EEZZ 44 Description Standard line feed character. Cyclical redundancy check number. m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, and two-digit zone code. The quote (“) is the separation character. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . Optional Silent Knight FSK1 (Message Type m) If Menu Item 2.5.16 in the D6600/D6100 Receiver is equal to1, the following output is used. Silent Knight FSK1 Example Table 76: SIA Mode Description [#aaaa|ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ]< CR> Optional Silent Knight FSK1 (Message Type m) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”Z Z Table 77: Description Standard line feed character. Cyclical redundancy check number. m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Up to eight reports. One report has two digits. The quote (“) is the separate character. Silent Knight FSK1 Optional Outputs Report Code Description To Automation 2 5 16 = 0(EEZZ) 2 5 16 = 1(ZZ) 00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 81 to 89 Alarm Panic Alarm 01 to 08 Holdup Alarm 10 to 19 Alarm Restore 10 to 19 Test Code Trouble Line 1 Trouble Line 2 Expand Trouble Forced Access Restore Line 1 Restore Line 2 Expand Restore Cancel Code Data Lost Closing Closing 01 to 09 Bypass 10 to 19 Trouble AC Trouble 01 to 08 Trouble BAT Restore AC Restore 01 to 08 Restore BAT Access Access 01 to 09 PAss sA0x Hass sA1x sH1x sXss LT01 LT02 ETss DFss LR01 LR02 ERss OCss RTss CL00 CL0x sB1x ATss sT0x YTss ARss sRss YRss DS00 DG0x 00 01 to 08 09 10 to 19 20 to 29 30 31 32 33 34 35 36 37 38 39 40 41 to 49 50 to 59 60 61 to 68 69 70 71 to 78 79 80 80 to 89 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Note x = 1 to 8 x = 0 to 9 x = 0 to 9 x = 1 to 9 x = 0 to 9 x = 1 to 8 x = 1 to 9 45 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Table 77: Computer Communication Protocols Silent Knight FSK1 Optional Outputs (continued) Report Code Description To Automation 90 91 to 99 Opening Opening 01 to 09 OP00 OP0x Note 90 91 to 99 3.2.24 Silent Knight FSK2 (Message Type m) Silent Knight FSK2 Example Table 78: SIA Mode Description [#aaaaaa| EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ] Silent Knight FSK2 (Message Type m) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EEZZ”EEZZ”EEZZ”EEZZ” EEZZ”EEZZ”EEZZ”EEZZ 46 Description Standard line feed character. Cyclical redundancy check number. m The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. Up to eight reports. One report has four digits: one-digit event code, one-digit condition code, and two-digit zone code. The quote (“) is the separation character. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.2.25 Silent Knight FSK80 (Message Type E) Silent Knight FSK80 Example Table 79: SIA Mode Description [#AAAA|NBAXY] Silent Knight FSK80 (Message Type E) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # NBA Description Standard line feed character. Cyclical redundancy check number. E The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Alarm event Figure 23: Message sent to printer MM/DDsHH:MMsLxxsSFKsACCTsAAAA +++ACCTsAAAAsALARM_ZNs1 +++ACCTsAAAAsALARM_ZNs2 +++ACCTsAAAAsALARM_ZNs3 +++ACCTsAAAAsALARM_ZNs4 +++ACCTsAAAAsALARM_ZNs5 +++ACCTsAAAAsALARM_ZNs7 +++ACCTsAAAAsALARM_ZNs8 +++ACCTsAAAAsALARM_ZNs9 Table 80: Characters MM/DDsHH:MM SFK Lxx AAAA s Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Silent Knight FSK80 Printer/LCD output Description Date and time. SFSK80 format. Line number. The communicator's account number has four digits. Space. 47 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.2.26 Telim (Message Type n) Telim Example Table 81: SIA Mode Description [#aaaaaa|EETTZZZZZZZZZZZZZZZZZZ] Telim (Message Type n) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # EETTZZZZZZZZZZZZZZZZ ZZ Description Standard line feed character. Cyclical redundancy check number. n The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to six digits. The event type and input line number. 3.2.27 Varitech FSK 4-1 (Message Type ) Varitech FSK 4-1 Example Table 82: Varitech FSK 4-1 (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account# data 48 SIA Mode Description [#aaaa|data] Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99 The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. The event type and 1-digit zone number. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.2.28 Varitech FSK 4-2 (Message Type ) Varitech FSK 4-2 Example Table 83: SIA Mode Description [#aaaa|data] Varitech FSK 4-2 (Message Type ) Byte Description Title LF CRC Message sequence# receiver# line# (Line/Group #) account # data Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. The event type and two-digit zone number. 3.2.29 VONK (Message Type V) VONK Example Table 84: SIA Mode Description [#aa|123456789ABCDEFG] VONK (Message Type V) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # Data Description Standard line feed character. Cyclical redundancy check number. V The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has two digits. Status of zones 1 to 16. If the zone is closed, a “.” (Period) appears in this position. If the zone is open, any digit from 1 to G appears in this position. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 49 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols 3.2.30 X-SIA text (Message Type ) X-SIA Example Table 85: SIA Mode Description [#aaaa|EMMZZZZ*'TTTTTTTTTTTTT' NM/***] X-SIA text (Message Type ) Byte Description Title LF CRC Message Type sequence# receiver# line# (Line/Group #) account # E MM ZZZZ * ` TT…TTT ‘ NM / *** Description Standard line feed character. Cyclical redundancy check number. The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600/D6100. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has up to 16 digits. SIA block code. SIA event code. Zone number. Text identifier. Single quote. 13 character text string. Single quote. Unit field characters. Separator. Next data. Figure 24: Message sent to printer MM/DDsHH:MMsLxxsSIAsACCTsAAAA +++sEMMZZZZ*'TTTTTTTTTTTTT'NM +++sEMMZZZZ*'TTTTTTTTTTTTT'NM 50 Table 86: X-SIA Printer/LCD output Characters MM/DDsHH:MM Lxx SIA AAAA E MM ZZZZ * ‘ TTT…T ‘ NM Description Date and time. Line number. SIA format. Account code. SIA block code. SIA event code. Zone number. Text identifier. Single quote. 13 character text string. Single quote. Unit field characters. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.2.31 SafeCom (Message Type p) SafeCom Example Table 87: Title LF CRC Message sequence# receiver# line# account # EEEE data SIA Mode Description

[#aaaa|EEEEdata] SafeCom (Message Type p) Byte Description Description Standard line feed character. Cyclical redundancy check number. p The message sequence number. The valid sequence number range is 0001 to 9999. The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600. The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number has four digits. Event code, four digits. Event code parameter data. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 51 Conettix D6600/D6100i | Computer Interface Manual | 3.0 3.3 Input Command Processing Input devices, such as automation systems, send the commands described in Table 88 to the receiver. If the receiver does not recognize a command, it generates a REJECT COMMAND message, prints at connected printers, and sends an ASCII text message to the automation port. The CPU programming in Menu Item 2.2.4 of the D6600/D6100 Receiver must be set to 1 to use input commands. Table 88: ASCII Text Message to Automation Port Set Time The automation system, or other device, sends the command shown below to set the time at the D6600/D6100 if the D6600/D6100 is programmed to synchronize the time and date with the automation system. !Thhmm D6650 Mode: [CSThhm SIA m] Mode: hh - hours (24 hour format) mm – minutes. The automation system, or other device, sends the command shown below to set the date at the D6600/D6100 if the D6600/D6100 is programmed to synchronize the time and date with the automation system. !Dmmddyy D6650 Mode: [CSDmmd SIA dyy] Mode: mm - month, dd - day, yy – year The automation system, or other device, sends the command shown below to stop a two way audio session on the line specified. !Kn D6650 Mode: [CLKnn] SIA Mode: nn - line card number, 01-32. h3rrlsREJECTsCOMMANDsst D6650 Mode: [RE Mode: JECT COMMAND] Set Date Stop Two Way Audio Reject Command 52 Computer Communication Protocols Table 89 shows the D6500 and SIA automation output formats for these input commands. Table 89: Set Time Set Date Stop Two Way Audio Input Command Output Messages D6500 Mode h1rrssssss ssssssXss2 t h1rrssssss ssssssXss5 1t h1rrssssss ssssssXss5 2t SIA Mode [NJT] Printer Output TIME SET [NJD] DATE SET [CLK] TWO WAY AUDIO STOP STOP Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Appendix A: Contact ID Event Code Classifications Figure 25: Contact ID format 1 2 3 4 5 1234 E 123 01 123 1234- Customer (Subscriber Account Number) Event Qualifier - E = New Event, R = Restore Event Code - refer to Section A1 Event Codes Partition Number, 00 to 08 (always 00 for nonpartitioned panels) 5 - Zone ID number* - reporting the alarm (001 to 999) or user number for open or close reports. * System status messages, such as AC Loss and Low Battery, are Zone ID 000. Table 90: # Event Codes Event Type Medical: 100 Medical 101 Pendant Transmitter 102 Fail to report in Fire Alarms: 110 Fire 111 Smoke w/Verification 112 Combustion 113 Waterflow 114 Heat 115 Pull Station 116 Duct 117 Flame 118 Near Alarm Panic Alarms: 120 Panic Alarm 121 Duress 122 Silent 123 Audible 124 Duress-Access Granted 125 Duress-Egress Granted Zone Emerg-Personal Emergency-# Emerg-Personal Emergency-# Emerg-Fail to check in-# Fire-Fire Alarm-# Fire-Fire Alarm-# Fire-Combustion-# Fire-Water Flow-# Fire-Heat Sensor-# Fire-Pull Station-# Fire-Duct Sensor-# Fire-Flame Sensor-# Fire-Near Alarm-# Panic-Panic-# Panic-Duress-User # Panic-Silent Panic-# Panic-Audible Panic-# Panic-Duress Access Grant-# Table 90: # Event Codes (continued) Event Type Burglar Alarms: 130 Burglary 131 Perimeter 132 Interior 133 24 HR Burg (Aux) 134 Entry/Exit 135 Day/Night 136 Outdoor 137 Tamper 138 Near Alarm 139 Intrusion Verifier General Alarms: 140 General Alarm 141 Polling Loop Open 142 Polling Loop Short (AL) 143 Expansion Mod Failure 144 Sensor Tamper 145 Expansion Module Tamper 146 Silent Burg Zone Burg-Burglary-# Burg-Perimeter-# Burg-Interior-# Burg-24 Hour-# Burg-Entry/Exit-# Burg-Day/Night-# Burg-Outdoor-# Burg-Tamper-# Burg-Near Alarm-# Burg-Intrusion Verifier-# Alarm-General Alarm-# Alarm-Polling Loop Open Alarm-Polling Loop Short Alarm-Exp. Module Tamper-# Alarm-Sensor Tamper-# Alarm-Exp. Module Tamper-# Alarm-Silent Burglary-# Panic-Duress Egress Grant-# Bosch Security Systems, Inc. | 9/07 | 4998122703-02 53 Conettix D6600/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications Table 90: # Event Codes (continued) Event Type 24 Hour Non-Burglary: 150 24 Hour (Auxiliary 151 Gas Detected 152 Refrigeration 153 Loss of Heat 154 Water Leakage 155 Foil Break 156 Day Trouble 157 Low Bottled Gas Level 158 High Temp 159 Low Temp 161 Loss of Air Flow 162 Carbon Monoxide Detected 163 Tank Level Fire Supervisory: 200 Fire Supervisory 201 Low Water Pressure 202 Low CO2 203 Gate Valve Sensor 204 Low Water Level 205 Pump Activated 206 Pump Failure System Troubles: 300 System Trouble 301 AC Loss 302 Low System Batt 303 RAM Checksum Bad 304 ROM Checksum Bad 305 System Reset 306 307 308 309 310 311 312 313 54 Panel Prog Change Self-Test Failure System Shutdown Battery Test Fail Ground Fault Battery Missing Power Supply Overcurrent Engineer Reset Zone Alarm-24 Hr. Non-Burg-# Alarm-Gas Detected-# Alarm-Refrigeration-# Alarm-Heating System-# Alarm-Water Leakage-# Trouble-Foil Break-# Trouble-Day Zone-# Alarm-Low Gas Level-# Alarm-High Temperature-# Alarm-Low Temperature-# Alarm-Air Flow-# Alarm-Carbon Monoxide-# Trouble-Tank Level-# Super.-Fire Supervisory-# Super.-Low Water Pressure-# Super.-Low CO2-# Super.-Gate Valve-# Super.-Low Water Level-# Super.-Pump Activation-# Super.-Pump Failure-# Trouble-System Trouble Trouble-AC Power Trouble-Low Battery Trouble-Bad RAM Checksum (Restore not applicable) Trouble-Bad ROM Checksum (Restore not applicable) Trouble-System Reset (Restore not applicable) Trouble-Programming Changed (Restore not applicable) Trouble-Self Test Failure Trouble-System Shutdown Trouble-Battery Test Failure Trouble-Ground Fault-# Trouble-Battery Missing Trouble-Pwr. Supp. Overcur.-# Table 90: # Event Codes (continued) Event Type Sounder/Relay Troubles: 320 Sounder/Relay 321 BELL 1 322 BELL 2 323 Alarm Relay 324 Trouble Relay 325 Reversing Relay 326 Notification Appliance CKT. #3 327 Notification Appliance CKT. #4 System Peripheral Troubles: 330 System Peripheral 331 Polling Loop Open 332 Polling Loop Short 333 Exp. Module Failure 334 Repeater Failure 335 Local Printer Paper Out 336 Local Printer Failure 337 Exp. Mod. DC Loss 338 Exp. Mod. Low bat 339 Exp. Mod. Reset 341 Exp. Mod. Tamper 342 Exp. Module AC Loss 343 Exp. Module Self Test Fail 344 RF Rcvr Jam Detect # Communication Troubles: 350 Communication 351 352 353 354 355 356 357 Telco 1 Fault Telco 2 Fault LR Radio Xmitter Fault Failure To Communicate Loss of Radion Super. Loss of Central Polling LRR XMTR. VSWR Zone Trouble-Sounder/Relay-# Trouble-Bell/Siren #1 Trouble-Bell/Siren #2 Trouble-Alarm Relay Trouble-Trouble Relay Trouble-Reversing Relay Trouble-Notification Appl. Ckt#3 Trouble-Notification Appl. Ckt#4 Trouble-Sys. Peripheral-# Trouble-Polling Loop Open Trouble-Polling Loop Short Trouble-Exp. Module Fail-# Trouble-Repeater Failure-# Trouble-Printer Paper Out Trouble-Local Printer Trouble-Exp. Mod. DC Loss-# Trouble-Exp. Mod. Low Batt-# Trouble-Exp. Mod. Reset-# Trouble-Exp. Mod. Tamper-# Trouble-Exp. Module AC Loss-# Trouble-Exp. Self-Test Fail-# Trouble-RF Rcvr Jam Detect# Trouble-Communication Failure Trouble-Phone line #1 Trouble-Phone line #2 Trouble-Radio Transmitter Trouble-Fail to Communicate Trouble-Radio Supervision Trouble-Central Radion Polling Trouble-Radio Xmitter. VSWR-# Status-Engineer Reset-User # (Restore not applicable) Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 90: # Event Codes (continued) Event Type Protection Loop: 370 Protection Loop 371 Protection Loop Open 372 Protection Loop Short 373 Fire Trouble 374 Exit Error (By User) 375 Panic Zone Trouble 376 Hold-Up Zone Trouble Sensor: 380 Sensor TRBLGlobal 381 Loss Of Supervision 382 Loss Of Supervisn 383 384 385 386 387 388 389 391 392 393 Sensor Tamper RF Low Battery Smoke Hi Sens. Smoke lo sens. Intrusion hi sens. Intrusion lo sens. Det. Self test fail Sensor Watch Failure Drift Comp. Error Maintenance Alert Zone Trouble-Protection Loop-# Trouble-Prot. Loop Open-# Trouble-Prot. Loop Short-# Trouble-Fire Loop-# Alarm-Exit Error-# Trouble-PA Trouble-# Trouble-Hold-Up Trouble-# Table 90: # Event Codes (continued) Event Type Open/Close: 400 Open/Close 401 Open/Close By User 402 Group O/C 403 Automatic Open/Close 404 Late to O/C 405 Deferred O/C 406 407 Trouble-Sensor Trouble-# 408 Cancel (By User) Remote Arm/Disarm Quick Arm Trouble-RF Sensor Super.-# 409 Trouble-RPM Sensor Super.# Trouble-Sensor Tamper-# Trouble-RF Sensor Battery-# Trouble-Smoke Hi Sens.-# Trouble-Smoke Lo Sens.-# Trouble-Intrusion Hi Sens.-# Trouble-Intrusion Lo Sens.-# Trouble-Sensor Test Fail-# Trouble-Sensor Watch Fail-# Trouble-Drift Comp. Error-# Trouble-Maintenance Alert-# Bosch Security Systems, Inc. | 9/07 | 4998122703-02 441 Keyswitch Open/Close Armed Stay 442 Keyswitch Armed Stay 450 Exception O/C 451 Early O/C 452 Late O/C 153 Failed to Open 454 Failed to Close 455 Auto-Arm Failed 456 457 458 Partial Arm Exit Error (User) User on Premises 459 Recent Close 461 Wrong Code Entry 462 Legal Code Entry 463 Re-arm after Alarm Zone Opening/Closing Opening-User #/Closing-User # Closing-Group User # Opening-Automatic/ClosingAutomatic Opening-Late/Closing-Late Event & Restore Not Applicable Opening-Cancel Opening-Remote/ClosingRemote Event not applicable for opening/closing-Quick Arm Opening-Keyswitch/ClosingKeyswitch Opening-Armed Stay/ClosingArmed Stay Opening-Keysw. Arm Stay/Opening-Keysw. Arm Stay Opening-Exception/ClosingException Opening-Early/Closing-EarlyUse r# Opening-Late/Closing-LateUser # Trouble-Fail to open (Restore not applicable) Trouble-Fail to Close (Restore not applicable) Trouble-Auto Arm Failed (Restore not applicable) Closing-Partial arm-User # Closing-Exit Error-User # Opening-User on Prem. –User # Trouble-Recent Close-User # (Restore not applicable) Access-Wrong Code entry (Restore not applicable) Access-Legal Code entry-user # (Restore not applicable) Status-Re Arm After AlarmUser # (restore not applicable) 55 Conettix D6600/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications Table 90: # Event Codes (continued) Event Type Open/Close: 464 Auto Arm Time Extended 465 Panic Alarm Reset Remote Access: 411 Callback Requested 412 SuccessDownload/access 413 Unsuccessful Access 414 System Shutdown 415 Dialer Shutdown 416 Successful Upload Access Control: 421 Access Denied 422 423 424 Access Report by User Forced Access Egress Denied 425 Egress Granted 426 Access Door Propped Open 427 Access Point DSM Trouble 428 Access Point RTE Trouble 429 Access Program Mode Entry 430 Access Program Mode Exit 431 Access Threat Level Change 432 Access Relay/Trigger Fail 433 Access RTE Shunt 434 Access DSM Shunt System Disables: 501 Access Reader Disable 56 Zone Status-Auto Arm Time Ext.User # (Restore not applicable) Status-PA Reset (Restore not applicable) Remote-Callback Requested (Restore not applicable) Remote-Successful Access (Restore not applicable) Remote-Unsuccessful Access (Restore not applicable) Remote-System Shutdown Remote-Dialer Shutdown Remote-Successful Upload (Restore not applicable) Access-Access Denied-User # (Restore not applicable) Access-Access Gained-User # (Restore not applicable) Panic-Forced Access-# Access-Egress Denied (Restore not applicable) Access-Egress Granted (Restore not applicable) Access-Door Propped Open# Access-ACS Point DSM Trbl.# Access-ACS Point RTE Trbl.# Access-ACS Prog. Entry-User # (Restore not applicable) Access-ACS Prog. Exit-User # (Restore not applicable) Access-ACS Threat Level Chg. Access-ACS Relay/Trig. Fail# Access-ACS RTE Shunt-# Access-ACS DSM Shunt-# Table 90: # Event Codes (continued) Event Type Sounder/Relay Disables: 520 Sounder/Relay Disable 521 Bell 1 Disable 522 Bell 2 Disable 523 Alarm Relay Disable 524 Trouble Relay Disable 525 Reversing Relay Disable 526 Notification Appliance Ckt #3 527 Notification Appliance Ckt #4 System Peripheral Disables: 531 Module Added 532 Module Removed Communication Disables: 551 Dialer Disabled 552 Radio Xmitter Disabled 553 Remote Upload/Download Bypasses: 570 Zone/Sensor Bypass 571 Fire Bypass 572 24 Hour Zone Bypass 573 Burg. Bypass 574 Group Bypass 575 Swinger Bypass 576 Access Zone Shunt 577 Access Point Bypass Zone Disable-Sounder/Relay-# Disable-Bell/Siren #1 Disable-Bell/Siren #2 Disable-Alarm Relay Disable-Trouble Relay Disable-Reversing Relay Disable-Notification Appl. Ckt #3 Disable-Notification Appl. Ckt #4 Super.-Module Added (Restore not applicable) Super.-Module Removed (Restore not applicable) Disable-Dialer Disable Disable-Radio Disable Disable-Rem. Up/Download Disable Bypass-Zone Bypass-# Bypass-Fire Bypass-# Bypass-24 Hour Bypass-# Bypass-Burg. Bypass-# Bypass-Group Bypass-User # Bypass-Swinger Bypass-# Access-ACS Zone Shunt-# Access-ACS Point Bypass-# Disable-Access Rdr. Disable# Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 90: # Event Codes (continued) Event Type Test/Misc.: 601 Manual Test 602 Periodic Test 603 Periodic RF Xmission Fire Test Status Report To Follow Listen-In To Follow 604 605 606 607 608 609 Walk-Test Mode System Trouble Present Video XMTR Active 611 Point Tested OK 612 Point Not Tested 613 Intrusion Zone Walk Tested 614 Fire Zone Walk Tested 615 Panic Zone Walk Tested 616 Service Request Event Log: 621 Event Log Reset 622 Event Log 50% Full 623 Event Log 90% Full 624 Event Log Overflow 625 Time/Date Reset 626 Time/Date Inaccurate Program Mode Entry Program Mode Exit 627 628 Zone Test-Manually Triggered (Restore not applicable) Test-Periodic (Restore not applicable) Test-Periodic Radio (Restore not applicable) Test-Fire Walk Test-User # Test-Fire Walk-User # Listen-Listen-In Active (Restore not applicable) Test-Walk Test Mode-User # Test-System Trouble Present (Restore not applicable) Listen-Video Xmitter Active (Restore not applicable) Test-Point Tested OK-# (Restore not applicable) Test-Point Not Tested-# (Restore not applicable) Test-Intrn Zone Walk Test-# (Restore not applicable) Test-Fire Zone Walk Test-# (Restore not applicable) Test-PA Zone Walk Test (Restore not applicable) Trouble-Service Request Table 90: # Event Codes (continued) Event Type Scheduling: 630 Schedule Change 631 632 Exception Sched. Change Access Schedule Changes Zone Trouble-Schedule Changed (Restore not applicable) Trouble-Esc. Sched. Changed (Restore not applicable) Trouble-Access Sched. Changed (Restore not applicable) Personnel Monitoring: Trouble-Senior Watch Trouble 641 Senior Watch Trouble 642 Latch-key Status-Latch-key Super-User Supervision # (Restore not applicable) Special Codes: 750These codes are used only by Protection and can be 789 assigned any unique non-standard Event code that Pro 1 tracks. Trouble-Event Log Reset (Restore not applicable) Trouble-Event Log 50% Full (Restore not applicable) Trouble-Event Log 90% Full (Restore not applicable) Trouble-Event Log Overflow (Restore not applicable) Trouble-Time/Date Reset-User # (Restore not applicable) Trouble-Time/Date Invalid Trouble-Program Mode Entry (Restore not applicable) Trouble-Program Mode Exit (Restore not applicable) Bosch Security Systems, Inc. | 9/07 | 4998122703-02 57 Conettix D6600/D6100i | Computer Interface Manual | Appendix B: Internal Messages Appendix B: Internal Messages Table 91: Internal Messages # Internal Messages 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Acknowledge 1 Keypad Operation 1 Service Required Set Time Battery Missing 1 Battery Present Battery Bad Battery Restore AC Fail AC Restore 1 Paper In 1 Paper Out 1 Local Parameter Program In Local Parameter Program 1 Successful 1 Local Software Program In Local Software Program 1 Successful 1 Local Program Failure 1 Local Program Denied Remote Parameter Program In Remote Parameter Program Successful Remote Software Program In Remote Software Program Successful Remote Program Failure 1 Remote Program Denied 1 Printer On Line 1 Printer Off Line External PRT Error External PRT Restore 1 Internal PRT Error 1 Internal PRT Restore Busy Seconds COM3 Error COM3 Trouble COM3 Restore UPS AC Fail UPS AC Restore UPS Battery Low UPS Battery Restore 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 1 Internal message is not implemented. 2 Output messages are abbreviated. 58 D6500 2 Output SIA Output2 Printer Output X X X X X X X X X X X X X 0 1 2 9 10 11 12 13 14 15 16 17 18 [NYZ] [NYX] [NJT] [NYM] [NYR] [NYT] [NYR] [NAT] [NAR] [NVI] [NVO] [NLB] [NLS] Acknowledge OPERATOR KEYPAD OPERATION SERVICE REQUIRED TIME SET BATTERY MISSING BATTERY PRESENT BATTERY BAD BATTERY RESTORE AC FAIL AC RESTORE PAPER IN PAPER OUT LOCAL PARM PROGRAM IN LOCAL PARM PROGRAM SUCCESSFUL X 41 X 42 [NLB] [NLS] LOCAL SOFTWARE PROGRAM IN LOCAL SOFTWARE PROGRAM SUCCESS X X X X 43 44 45 46 [NLU] [NLD] [NRB] [NRS] LOCAL PROGRAM FAILURE LOCAL PROGRAM DENIED REMOTE PARM PROGRAM IN REMOTE PARM PROGRAM OK X 47 X 48 [NRB] [NRS] REMOTE SOFTWARE PROGRAM IN REMOTE SOFTWARE PROGRAM SUCCESS X 49 X 50 X 19 X 20 X 21 X 22 X 21 X 22 bbb B X 30 X 31 X 32 X 33 X 34 X 35 X 36 [NRU] [NRD] [NVY] [NVZ] [NVT] [NVR] [NVT] [NVR] [NYBbbb] [NYC] [NYS] [NYK] [NUA01] [NUR01] [NUA02] [NUR02] REMOTE PROGRAM FAILURE REMOTE PROGRAM DENIED PRINTER ON LINE PRINTER OFF LINE EXTERNAL PRINTER ERROR EXTERNAL PRINTER RESTORE INTERNAL PRINTER ERROR INTERNAL PRINTER RESTORE BUSY SECONDS bbb% COMPUTER ERROR COMPUTER TROUBLE COMPUTER RESTORE UPS AC FAIL UPS AC RESTORE UPS BATTERY LOW UPS BATTERY RESTORE Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix B: Internal Messages . Table 91: Internal Messages (continued) # Internal Messages D6500 2 Output SIA Output2 Printer Output 39. 40. 41. 42. 43. 44. 45. System Reset 1 System Default System Temperature High System Temperature Restore Slotx/Linex (Lxx) Line Fault Slotx/Linex (Lxx) Line Restore Slotx/Linex (Lxx) Line Card Trouble Slotx/Linex (Lxx) Line Card Restore Slotx/Linex (Lxx) Audio In Slotx/Linex (Lxx) Audio Done Slotx/Linex (Lxx) 1 Communication Error Slotx/Linex (Lxx) 1 Communication Restr Slotx/Linex (Lxx) Data Error Slotx/Linex (Lxx) No Data Received Slotx/Linex (Lxx) Reset 1 Slotx/Linex (Lxx) Codec Error Slotx/Linex (Lxx) Private Call Slotx/Linex (Lxx) No Call Number Slotx/Linex (Lxx) Caller Unknown Set Date Stop Two Way Audio 1 CPU Data Error 1 Network Error 1 Network Restore Account Status Failure Account Status Restore Supervision Rate Changed Switch To Intercept Mode Switch to Fallback Mode Diable Intercept Mode Activate Output Deactivate Output C900 Reboot C900 Battery Low C900 Battery Restore C900 Switched to Intercept C900 Switched to Fallback C900 Output Activated X X X X X X X [NYW01] [NYG] [NKA] [NKR] [NLT] [NLR] [NYD] SYSTEM RESET SYSTEM DEFAULT SYSTEM TEMPERATURE HIGH SYSTEM TEMPERATURE RESTORE PHONE LINE FAULT PHONE LINE RESTORE LINE CARD TROUBLE X 8 [NYE] LINE CARD RESTORE * L X 60 [NLF] [NLE] [NUA03] AUDIO IN AUDIO DONE COMMUNICATION ERROR X 61 [NUR03] COMMUNICATION RESTR X 62 X 63 [NYN] [NUT04] DATA ERROR NO DATA RECEIVED X 64 X 65 P N [NYW02] [NUT05] [NUT06] [NUT07] RESET CODEC ERROR PRIVATE CALL NO CALL NUMBER U [NUT08] CALLER UNKNOWN X 51 X 52 X 53 X 54 X 55 T B02 N B02 X 66 X 88 X 81 X 83 X 84 X 86 X 59 X 58 X 68 X 87 X 82 X 85 [NJD] [CLK] [NYN01] [NNT] [NNR] [NYC] [NYK] [NCO0001] [NCO0002] [NCO0003] [NCO0004] [NCO0005] [NCO0006] [NSC0001] [NSC0002] [NSC0003] [NSC0004] [NSC0005] [NSC0006] DATE SET TWO WAY AUDIO STOP CPU DATA ERROR NETWORK TROUBLE NETWORK RESTORE COMMUNICATIONS FAILURE COMMUNICATIONS RESTORED SUPERVISION RATE CHANGED SWITCH TO INTERCEPT MODE SWITCH TO FALLBACK MODE DISABLE INTERCEPT MODE ACTIVATE OUTPUT DEACTIVATE OUTPUT C900 REBOOT C900 BATTERY LOW C900 BATTERY RESTORE C900 SWITCHED TO INTERCEPT C900 SWITCHED TO FALLBACK C900 OUTPUT ACTIVATED 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. 1 Internal message is not implemented. 2 Output messages are abbreviated. 37 38 39 40 5 6 7 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 59 Conettix D6600/D6100i | Computer Interface Manual | Appendix B: Internal Messages Table 91: Internal Messages (continued) # Internal Messages D6500 2 Output SIA Output2 Printer Output 77. 78. 79. 80. 81. 82. 83. C900 Output Deactivated C900 Input Shorted C900 Input Open C900 Input Restored C900 Intercept Enabled C900 Intercept Disabled No Acknowledgement Received Not Dialing Dialing Error No Response to Handshake No Response to Acknowledgement Message Unknown Invalid Message 30 Minutes Since Fallback Command Invalid Message 30 Minutes Since Fallback Command Incompatible Incompatible X X X X X X X 94 89 90 91 92 93 71 [NSC0007] [NSC0008] [NSC0009] [NSC0010] [NSC0011] [NSC0012] [NYU0001] C900 OUTPUT DEACTIVATED C900 INPUT SHORTED C900 INPUT OPEN C900 INPUT RESTORED C900 INTERCEPT ENABLED C900 INTERCEPT DISABLED NO ACKNOWLEDGEMENT RECEIVED X X X X 72 73 74 75 [NYU0002] [NYU0003] [NYU0004] [NYU0005] NOT DIALING DIALING ERROR NO RESPONSE TO HANDSHAKE NO RESPONSE TO ACK X 76 X 77 X 95 [NYU0006] [NYU0007] [NMI0001] MESSAGE UNKNOWN INVALID MESSAGE 30 MIN SINCE FALLBACK CMD X 77 X 95 [NYU0007] [NMI0001] INVALID MESSAGE 30 MIN SINCE FALLBACK CMD X 99 X 100 [NIVn] [NIUn] INCOMPATIBLE FIRMWARE INCOMPATIBLE HARDWARE 84. 85. 86. 87. 88. 89. 90. 91. 92. 97. 98. 1 Internal message is not implemented. 2 Output messages are abbreviated. 60 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Appendix C: Modem IIIa2 Messages For lines that are grouped, Gxx appears instead of Lxx. Table 92: 1. 2. 3. 4. Modem IIIa2 Messages Event Device/Mode Display Abort (User not identified) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=a h1rrlssssssaaaasIsD41t

[#aaaa|NriaAB] dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasIsiiit
[#aaaa|Nria/idiiiAB] dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasIiiiit
[#aaaa|Nriaa/idiiiiAB] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nria/idiiiDGppp] or
[#aaaa|Nria/idiii/ssxDGppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iiii POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nria/idiiiiDGppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/idiiiDGpppp] or
[#aaaa|Nriaa/idiii/ssxDGpppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/idiiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa AC FAILURE +++ACC aaaa AREA=aa h1rrlssssssaaaasPsssst
[#aaaa|NriaaAT] dd/dd tt:tt Lxx ACC aaaa AC FAILURE h1rrlssssssaaaasPsssst
[#aaaa|NAT] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTssszt
[#aaaa|NATO] dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasPsssst
[#aaaa|NAT] Abort (users < 255) Abort (users > 254) Access Granted D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 5. 6. 7. 8. Access Granted (point < 255, user > 254) Access Granted (point > 254, user < 255) Access Granted (point > 254, user > 255) AC Fail (Area reported) 9. AC Fail 10. AC Fail 11. AC Fail (as a rider) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Explanation TROUBLE Refer to Section C.1 Zonex and Comex Translation on page 137. No AC power. Control panel is running on battery power only. You can program the control panel to defer this report. ZN z 2, z=0 AC FAILED No AC power. Control anel is running on battery power only. This report is sent along with the next report transmitted - it is not transmitted independently. 2, D9112 61 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 12. AC Fail Since Last Call Printer: D6500 Mode: SIA Mode: +++ ACC aaaa h1rrlssssssaaaaSPsssst
[#aaaa|OAT] 13. AC Restoral (Area reported) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa AC RESTORAL +++ACC aaaa AREA=aa h1rrlssssssaaaasRsss0t
[#aaaa|NriaaAR] dd/dd tt:tt Lxx ACC aaaa AC RESTORAL h1rrlssssssaaaasRsss0t
[#aaaa|NAR] dd/dd tt:tt Lxx ACC aaa RESTORAL ZN z h1rrlssssssaaaasRssszt
[#aaaa|NURO] dd/dd tt:tt AC RESTORED RCVR rr h1rrssssssssssssXss14t
[NAR] dd/dd tt:tt AC TROUBLED RCVR rr h1rrssssssssssssXss13t
[NAT] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT h1rrlssssssaaaasAsssst
[#aaaa|NBA] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAssszzt
[#aaaa|NBAz] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAszyyt
[#aaaa|NBAzyy] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAssxxt
[#aaaa|NBAxx] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasAss16t
[#aaaa|NBA16] Printer: dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaBApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaBApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ ACC aaaa POINT=ppp +++ ACC aaaa ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NBAppp] 14. AC Restoral 15. AC Restoral 16. AC Restored 17. AC Troubled 18. Alarm 19. Alarm 20. Alarm 21. Alarm 22. Alarm 23. Alarm (points > 254) 24. 25. Alarm (with Ground Fault) (points > 254) Alarm (Area Not Reported) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 62 AC FAILURE Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. No AC power. Control panel is running on battery power only. You can program the control panel to defer this report. 5. AC power restored. D7112 2, z=0 Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report. ALARM ZN z 1,10 2,9 ALARM ZN zyy ALARM ZN zxx ALARM ZN 16 Alarm condition on the zone number shown. Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: 26. 27. 28. 29. 30. 31. 32. 33. Modem IIIa2 Messages (continued) Event Device/Mode Display Alarm (points < 255) Printer: dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaBAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|Nria/idiiiCRppp] Alarm with Recent Closing Created due to alarm within 2 min of close (points < 255) 35. D6500 Mode: SIA Mode: Alarm with Recent Closing Created due to alarm within 2 min of close (points > 254, user < 255) Alarm with Recent Closing Created due to alarm within 2 min of close (points > 254, user > 254) Printer: Alarm with Recent Closing Created due to alarm within 5 min of close (with Ground Fault) (points > 254, user < 255) Alarm with Recent Closing Created due to alarm within 5 min of close (with Ground Fault) (points > 254, user > 254) Alarm Cross Point (points < 255) Printer: Alarm Cross Point (Area Not Reported) 34. D6500 Mode: SIA Mode: Printer: Alarm Cross Point (points > 254) Alarm Cross Point (with Ground Fault) (points > 254) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAsppppt
[#aaaa|Nriaa/idiiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaBMppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ ACC aaaa CROSS POINT +++ ACC aaaa POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NBMppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaBMpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT, GROUND FAULT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaBMpppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report. 63 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: 36. 37. 38. 39. 40. 41. 42. Modem IIIa2 Messages (continued) Event Device/Mode Display Alarm Door Forced (points > 254) Printer: dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaDFpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ ACC aaaa EXIT ERROR h1rrlssssssaaaasAspppt
[#aaaa|NidiiiEAppp] Alarm Exit Error (Area Not Reported) Alarm Exit Error (points < 255) Alarm Exit Error (points > 254, user < 255)) Alarm Exit Error (points > 254, user > 254) Alarm Exit Error (with Ground Fault) (points > 254, user < 255) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Alarm Exit Error (with Ground Fault) (points > 254, user > 254) Printer: 43. Alarm Fire 44. Alarm Silenced Printer: D6500 Mode: SIA Mode: Printer: 45. All Points Tested 46. Analog Restoral (points < 255) 47. Analog Restoral (points < 255) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 64 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Unexpanded alarm report. Alarm report from the POINT in the AREA specified in the second line of the report. dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|Nria/idiiiEAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiiEApppp] dd/dd tt:tt Lxx ACC aaaa FIRE FR z h1rrlssssssaaaasFssszt
[#aaaa|NFAz] dd/dd tt:tt Lxx ACC aaaa ALARM SILENCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaFSppppt
[#aaaa|NriaaFLpppp] dd/dd tt:tt Lxx ACC aaaa ALL PTS TESTED h1rrlssssssaaaasRsssFt
[#aaaa|NTC] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaANppp] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaANppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: 48. 49. 50. 51. 52. 53. 54. 55. 56. Modem IIIa2 Messages (continued) Event Device/Mode Display Analog Restoral (points > 254) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRsppppt
[#aaaa|NriaaANpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRsppppt
[#aaaa|NriaaANpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaASppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTsppppt
[#aaaa|NriaaASpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTsppppt
[#aaaa|NriaaASpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=aa POINT=pppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaasTsppppt
[#aaaa|Nriaa/lvlll/vavvvASpppp] dd/dd tt:tt Lxx ACC aaaa AREA WATCH +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD51t
[#aaaa|Nria/idiiiTW] dd/dd tt:tt Lxx ACC aaaa WATCH MODE END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasNsD52t
[#aaaa|Nriaa/idiiiiTZ] dd/dd tt:tt Lxx ACC aaaa WATCH START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasNsD51t
[#aaaa|Nriaa/idiiiiTW] dd/dd tt:tt Lxx AUDIO DONE h1rrlsssssssssssLsssst
[NLE] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx AUDIO IN h1rrlsssssssssss*sssst
[NLF] dd/dd tt:tt Lxx ACC aaaa BATTERY LOW h1rrlssssssaaaasTsss9t
[#aaaa|NYT] Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTssszt
[#aaaa|NBT9] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasTsss9t
[#aaaa|NriaaYT] Analog Restoral (points > 254) Analog Service (points < 255) Analog Service (points > 254) Analog Service (points > 254) Analog Service (points > 254) (Level and Value Reported) Area Watch Area Watch (Watch mode ended) (users > 254) Area Watch (Watch mode started) (users > 254) 57. Audio Done 58. Audio In 59. Battery Low 60. Battery Low 61. Battery Low (Area reported) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Explanation TROUBLE ZN z Refer to Section C.1 Zonex and Comex Translation on page 137. The control panel battery discharged to 11.8 VDC or less. 2, z=9 BATTERY LOW AREA=aa 65 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 63. Battery Low Since Last Call Printer: D6500 Mode: SIA Mode: +++ ACC aaaa h1rrlssssssaaaaSTsssst
[#aaaa|OYT] 64. Battery Missing Since Last Call Printer: D6500 Mode: SIA Mode: +++ ACC aaaa h1rrlssssssaaaaSTsssst
[#aaaa|OYM] 65. Battery Restoral (Area reported) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa BATTERY RESTORE +++ACC aaaa AREA=aa h1rrlssssssaaaasRsss9t
[#aaaa|NriaaYR] dd/dd tt:tt Lxx ACC aaaa BATTERY MISSING h1rrlssssssaaaasTsss9t
[#aaaa|NYM] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBT9] dd/dd tt:tt BATTERY MISSING RCVR rr h1rrssssssssssssXsss9t
[NYM] dd/dd tt:tt BATTERY PRESENT RCVR rr h1rrssssssssssssXss10t
[NYR] dd/dd tt:tt Lxx ACC aaaa BATTERY RESTORE h1rrlssssssaaaasRsss9t
[#aaaa|NYR] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaa RESTORAL ZN z h1rrlssssssaaaasRssszt
[#aaaa|NUR9] dd/dd tt:tt BATTERY RESTORED RCVR rr h1rrssssssssssssXss12t
[NYR] print blank line (CR and LF) 66. Battery Missing 67. Battery Missing 68. Battery Missing 69. Battery Present 70. Battery Restoral 71. Battery Restoral 72. Battery Restoral 73. Blank Line 74. Busy Seconds 75. Bypass, Command 76. Bypass, Programmer D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 66 BATTERY LOW BATTERY MISSING dd/dd tt:tt Lxx BUSY SECONDS bbb% RCVR rr h1rrlsssssssbbbsBsssst
[NYBbbb] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|Nria/idiiiUBppp] dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt
[#aaaa|Nria/pidddUBppp] Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The control panel battery discharged to 11.8 VDC or less. 5. The control panel battery is connected incorrectly, disconnected, or completely discharged. 5. The control panel battery is connected incorrectly, disconnected, or completely discharged. 2, z=9 The control panel battery charged to 13.2 VDC after a BATTERY LOW was reported (the battery is fully charged at 13.8 VDC). 2, z=9 The POINT in the AREA in the second line of the report is faulted, and was bypassed by a programmer with the specified serial device number when the system was armed. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: 77. 78. 79. 80. 81. 82. 83. 84. 85. 86. 87. Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation Bypass, Remote (Call back) Printer: dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ ACC aaaa AREA=a POINT=ppp PH#=h h1rrlssssssaaaasNspppt
[#aaaa|Nria/phhUBppp] The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by a RAM through the specified phone line. Bypass, Remote (No Call back) Printer: dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by a RAM through the specified phone line. Bypass Restore Printer: Bypass Restore (points < 255) Bypass Restore (point < 255) (Fire point) Bypass Restore (points < 255) (Supervisory point) Bypass Restore (points < 255) (Waterflow point)) Bypass Restore (point > 254) Bypass Restore (point > 254) (Fire point) Bypass Restore (point > 254) (Supervisory point) Bypass Restore (point > 254) (Waterflow point) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa POINT=ppp h1rrlssssssaaaaRBspppt
[#aaaa|NUUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt
[#aaaa|NriaUUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa FIRE POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt
[#aaaa|NriaFUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt
[#aaaa|NriaSUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt
[#aaaa|NriaWUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaUUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa FIRE POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaFUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaSUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaWUpppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 67 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: 88. Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation Bypass, Sked Printer: dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ ACC aaaa AREA=a POINT=ppp SKED=kk h1rrlssssssaaaasNspppt
[#aaaa|Nria/aikkUBppp] The POINT in the AREA in the second line of the report is faulted, and was bypassed when the system was armed by the specified Sked. D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] The POINT in the AREA in the second line of the report (that was programmed for swinger bypass) is faulted, and was bypassed while the system was armed. If the point restores while the system is armed, it returns to the system, and is ready to detect faults. A system in alarm was disarmed before the bell time expired. The specified point sends a Cancel Report for the alarmed area. D6500 Mode: SIA Mode: 89. Bypass, Swinger Printer: 90. Cancel Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas\sssst
[#aaaa|NOC] 91. Cancel 92. Cancel 93. Cancel Alarm Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa CANCEL ID i h1rrlssssssaaaas\sssit
[#aaaa|NOCi] dd/dd tt:tt Lxx ACC aaaa CANCEL ID iyy h1rrlssssssaaaas\siyyt
[#aaaa|NOCiyy] dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\sssst
[#aaaa|Nria/idiiiBC] D6500 Mode: SIA Mode: 94. 95. Cancel Alarm (Area Not Reported) Printer: Cancel Alarm (Non-Fire) Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 96. 97. 68 Cancel Alarm (Non-Fire) Cancel Alarm (Non-Fire) (users > 254) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaas\sssst
[#aaaa|NidiiiBC] CANCEL REPORT The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. CANCEL ALARM ID=iii The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\siiit
[#aaaa|Nria/idiiiBC] The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. Refer to Section C.1 Zonex and Comex Translation on page 137. 1. dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa AREA=a h1rrlssssssaaaas\sssst
[#aaaa|NriaBC] dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaas\iiiit
[#aaaa|Nriaa/idiiiiBC] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 98. Cancel Alarm by Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaas\sssst
[#aaaa|NOC] 99. Cancel, Fire Alarm Printer: dd/dd tt:tt Lxx ACC aaaa FIRE CANCEL +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\siiit
[#aaaa|Nria/idiiiFC] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ ACC aaaa BY PROGRAMMER +++ ACC aaaa CRD=iii-x SDI=ddd h1rrlssssssaaaasNsD30t
[#aaaa|NpidddDAiii] or
[#aaaa|Npiddd/ssxDAiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iiii SDI=ddd h1rrlssssssaaaasNsD30t
[#aaaa|Npiddd/DAiiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ ACC aaaa BY REMOTE +++ ACC aaaa CRD=iii-x h1rrlssssssaaaasNsD30t 100. Card Assigned (By Programmer) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 101. Card Assigned (By Programmer) (users > 254) 102. Card Assigned (By Remote) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 103. Card Assigned (By Remote) (users > 254) 104. Card Assigned (By User) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 105. Card Assigned (By User, User not identified) 106. Card Assigned (By User) (users > 254) 107. Card Deleted (By User, User not identified) 108. Card Deleted (By User) (users > 254) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: CANCEL REPORT Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. A system in alarm was disarmed before the bell time expired. The specified point sends a Cancel Report for the alarmed area. 2, 9
[#aaaa|NDAiii] or
[#aaaa|NssxDAiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY REMOTE +++ACC aaaa CRD=iiii h1rrlssssssaaaasNsD30t
[#aaaa|NDAiiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ ACC aaaa BY USER +++ ACC aaaa CRD=iii-x ID=iii h1rrlssssssaaaasNsD30t
[#aaaa|NidiiiDAiii] or
[#aaaa|Nidiii/ssxDAiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY USER h1rrlssssssaaaasNsD30t
[#aaaa|NDA] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY USER +++ACC aaaa CRD=iiii ID=iiii h1rrlssssssaaaasNsD30t
[#aaaa|NidiiiiDAiiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY USER h1rrlssssssaaaasNsD31t
[#aaaa|NDB] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY USER +++ACC aaaa CRD=iiii ID=iiii h1rrlssssssaaaasNsD31t
[#aaaa|NidiiiiDBiiii] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 69 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 109. Card Deleted (By Programmer) (users > 254) 110. Card Deleted (By Remote) (users > 254) 111. Card Restored 112. Card Troubled 113. Change Of Status (C900 Battery Low) 114. Checksum Fail Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iiii SDI=ddd h1rrlssssssaaaasNsD31t
[#aaaa|NpidddDBiiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY REMOTE +++ACC aaaa CRD=iiii h1rrlssssssaaaasNsD31t
[#aaaa|NDBiiii] dd/dd tt:tt Lxx CARD RESTORED RCVR rr h1rrlsssssssssssXsss8t
[NYE] dd/dd tt:tt Lxx CARD TROUBLED RCVR rr h1rrlsssssssssssXsss7t
[NYD] dd/dd tt:tt Nll ACC aaaa STATUS CHANGED +++ aaaa C900 BATTERY LOW h1rrlssssssaaaasXss58t
[#aaaa|NSC0002] dd/dd tt:tt Lxx ACC aaaa CHECKSUM FAIL h1rrlssssssaaaasAsD12t
[#aaaa|NYX] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 115. Checksum Fail (SDI Device and Point reported) Printer: Explanation The program in the control panel is corrupt. Send service immediately. D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa CHECKSUM FAIL +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasAspppt
[#aaaa|NpidddYXppp] The program in the control panel is corrupt. Send service immediately. 116. Closing Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCL] CLOSING REPORT The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. 117. Closing Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: CLOSING ZN i D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssit
[#aaaa|NCLi] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssit
[#aaaa|NCLi] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsiyyt
[#aaaa|NCLiyy] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCL] 121. Closing by Account (area not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit
[#aaaa|NCLi] 122. Closing by Account Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCL] 118. Closing 119. Closing 120. Closing by Account D6500 Mode: SIA Mode: 70 Refer to Section C.1 Zonex and Comex Translation on page 137. CLOSING ID i CLOSING ID iyy CLOSING REPORT ID=iii The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. CLOSING ZN i 2, i = user id. CLOSING REPORT ID=iii The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 123. Closing by Account (ID not reported) (area not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCL] CLOSING REPORT 124. Closing by Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst
[#aaaa|NCL] CLOSING REPORT 125. Closing by Area Printer: dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCL] D6500 Mode: SIA Mode: 126. Closing by Area 127. Closing by Area 128. Closing by Area (users > 254) 129. Closing by Area (ID not reported) 130. Closing Early By Account Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: CLOSING EARLY ID=iii D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCK] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit
[#aaaa|NCLi] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCK] CLOSING ZN i 133. Closing Early by Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst
[#aaaa|NCL] 134. Closing Early By Area Printer: dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCK] 131. Closing Early by Account 132. Closing Early By Account (ID not reported) Printer: dd/dd tt:tt Lxx ACC aaa CLOSING ZN z h1rrlssssssaaaasCssszt
[#aaaa|NCLz] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaCL] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCL] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaCL] D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. 1, The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. 2, The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. 1. D7112 D7112 2, z = area number The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. 1, A user with the ID in the second line of the report armed the AREA before the programmed closing time window. 1, D7112 D7112 2, i = user id. CLOSING EARLY CLOSING REPORT A user with the ID in the second line of the report armed the AREA before the programmed closing time window. 1, The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. 2, A user with the ID in the second line of the report has armed the AREA before the programmed closing time window. 1. D7112 D7112 71 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 135. Closing Early By Area 136. Closing Early by Area 137. Closing Early By Area (ID not reported) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NriaCK] dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCssszt
[#aaaa|NCLz] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NriaCK] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 138. Closing Early By Area (users > 254) CLOSING ZN z CLOSING EARLY AREA=a Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit
[#aaaa|NCLi] CLOSING ZN i 141. Closing Late by Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCJ] CLOSING LATE 142. Closing Late by Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst
[#aaaa|NCL] 143. Closing Late by Area Printer: dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCJ] 140. Closing Late by Account D6500 Mode: SIA Mode: 144. Closing Late by Area 145. Closing Late by Area 146. Closing Late by Area (users > 254) 72 Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 2, z = area number D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: Refer to Section C.1 Zonex and Comex Translation on page 137. CLOSING EARLY AREA=a dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCK] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ ACC aaaa ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCJ] 139. Closing Late by Account (area not reported) Printer: Explanation A user with the ID in the second line of the report armed the AREA before the programmed closing time window. 1, A user with the ID in the second line of the report armed the AREA after the programmed closing time window. 1, D7112 D7112 2, i = user id CLOSING REPORT dd/dd tt:tt Lxx ACC aaa CLOSING ZN z h1rrlssssssaaaasCssszt
[#aaaa|NCLz] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaCJ] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCJ] A user with the ID in the second line of the report armed the AREA after the programmed closing time window. 1, The system armed or disarmed with a passcode or COMMAND 1 reporting no User ID. 2, A user with the ID in the second line of the report armed the AREA after the programmed closing time window. 1. D7112 D7112 2, z = area number Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 147. Closing Late by Area (ID not reported) Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NriaCJ] 148. Command Bypass Printer: 149. Command Bypass 150. Command Bypass (point < 255, user > 254) 151. Command Bypass (point > 254, user < 255) 152. Comm Fail 153. Comm Fail (SDI Device not reported) 154. Comm Restoral D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Printer: D6500 Mode: SIA Mode: 155. Comm Restoral (SDI Device not reported) Printer: 156. Communicatio ns Fail (2212/9112) Printer: 157. Communicatio ns Trouble 158. Communicatio ns Trouble (Route Group and SDI Device# reported) 159. Communicatio ns Trouble Restoral D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Refer to Section C.1 Zonex and Comex Translation on page 137. A user with the ID in the second line of the report armed the AREA after the programmed closing time window. 1, dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ ACC aaaa AREA=a POINT=ppp ID=iii h1rrlssssssaaaasNspppt
[#aaaa|Nria/idiiiUBppp] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] D7112 1. 9, D9112 dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|Nria/idiiiiUBppp] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/idiiiUBpppp] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsB01t
[#aaaa|NphhYC] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa D6500 Mode: SIA Mode: CLOSING LATE AREA=a Explanation h1rrlssssssaaaasTsB01t
[#aaaa|NrggYC] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsB01t
[#aaaa|NphhYK] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsB01t
[#aaaa|NrggYK] COMM FAIL PHONE#=h COMM FAIL RG=g COMM RESTORAL PHONE#=h The PHONE# specified in the second line of the report was restored. COMM RESTORAL RG=g The PHONE# specified in the second line of the report was restored. dd/dd tt:tt Lxx ACC aaaa COMM FAIL +++ACC aaaa PH#=hh h1rrlssssssaaaasTsB01t
[#aaaa|NphhhYC] dd/dd tt:tt Lxx ACC aaaa COMM TROUBLE +++ACC aaaa PH#=hh h1rrlssssssaaaasTsB01t
[#aaaa|NphhhYS] dd/dd tt:tt Lxx ACC aaaa COMM TROUBLE +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasTsB01t
[#aaaa|Nrgg/pidddYS] dd/dd tt:tt Lxx ACC aaaa COMM TRBL RESTR +++ACC aaaa PH#=hh h1rrlssssssaaaasNsB01t
[#aaaa|NphhhYK] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 73 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 160. Communicatio ns Trouble Restoral (Route Group and SDI Device# reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa COMM TRBL RESTR +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasNsB01t
[#aaaa|Nrgg/pidddYK] 161. Computer Error Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx COMPUTER ERROR h1rr0sssssssssssXss30t
[NYC] Indicates a complete loss of communication between receiver and automation system. 162. Computer Restore Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx COMPUTER RESTORE h1rr0sssssssssssXss32t
[NYK] Indicates that communication between the receiver and the automation system was restored. 163. Computer Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx COMPUTER TROUBLE h1rr0sssssssssssXss31t
[NYS] Indicates that an automation message was rejected by the automation software. 164. Create Status Report Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasSsssst
[#aaaa|NYY] Indicates that the next report is an Account Status Report. 165. Custom Function (Custom Function Initiated) Printer: dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY CUSTOM FUNCTION +++ACC aaaa CUST.FX=fff AREA=aa ICF=fff h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/cffffCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY SKED +++ACC aaaa CUST.FX=fff AREA=aa SKED=kkk h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/aikkkCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa ID=iii h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/idiiiCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa ID=iiii h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/idiiiiCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa h1rrlssssssaaaasNsD39t
[#aaaa|NriaaCXfff] dd/dd tt:tt Lxx ACC aaaa DATE CHANGED +++ ACC aaaa ID= iii h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiJD] 166. Custom Function (Sked Initiated) 167. Custom Function (users < 255) (User Initiated) 168. Custom Function (users > 254) User Initiated) 169. Custom Function (User Initiated, User not identified) 170. Date Changed D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 171. Date Changed Printer: D6500 Mode: SIA Mode: 74 dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiJD] Explanation STATUS REPORT DATE CHANGED ID=iii The user changed the control panel date or time with the ID specified in the second line of the report. Refer to Section C.1 Zonex and Comex Translation on page 137. D9112 The user changed the control panel date or time with the ID specified in the second line of the report. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 172. Date Changed 173. Date Changed (users > 254) 174. Diagnostic 175. Diagnostic 176. Door Closed, Restoral 177. Door Cycled 178. Door Cycled (By User) 179. Door Cycled (By Programmer) (points > 254) 180. Door Cycled (By Remote) (points > 254) 181. Door Cycled (By User) (points < 255, users > 254) 182. Door Cycled (By User) (points > 254, users < 255) 183. Door Cycled (By User) (points > 254, users > 254) 184. Door Cycled (By User, User not identified) (points < 255) Device/Mode Display Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasNsD07t
[#aaaa|NJD] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiiJD] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasYsssst
[#aaaa|NYX] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. DATE CHANGED DATE CHANGED ID=iiii DIAG REPORT dd/dd tt:tt Lxx ACC aaaa DIAG ZN z h1rrlssssssaaaasYssszt
[#aaaa|NYXz] dd/dd tt:tt Lxx ACC aaaa REST-DR CLOSED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaDHppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nria/idiiiDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/pidddDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nria/idiiiiDGppp] A Command 42 was entered at a keypad to send a diagnostic report. No service conditions in trouble memory to report. The Modifier “/ssx” refers to the Data Type Address, not the Modifiers “idiii,” or “piddd” dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/idiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaAGpppptv
[#aaaa|Nriaa/idiiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDGppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 75 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 185. Door Cycled (By User, User not identified) (points > 254) 186. Door Cycled (points > 254) 187. Door Left Open 188. Door Left Open (points > 254) 189. Door Left Open (Point text reported) 190. Door Left Open, Alarm 191. Door Left Open, Alarm (points > 254) 192. Door Left Open, Alarm (Text reported) 193. Door Left Open, Alarm (Point text and User Name reported) 194. Door Left Open, Trouble 195. Door Left Open, Trouble (Text reported) 196. Door Left Open, Trouble (Point text and User name reported) 76 Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LFT OPN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAOspppt
[#aaaa|NriaDNppp] dd/dd tt:tt Lxx ACC aaaa DOOR LEFT OPEN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAOppppt
[#aaaa|NriaaDNpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (ptext) h1rrlssssssaaaaAOspppt
[#aaaa|NriaDNppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaDLpppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (text) h1rrlssssssaaaasAspppt
[#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa ALRM-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (ptext) +++ ACC aaaa (uname) h1rrlssssssaaaasAspppt
[#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa TRBL-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaDLppp] dd/dd tt:tt Lxx ACC aaaa TRBL-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (text) h1rrlssssssaaaasTspppt
[#aaaa|NriaDMppp] dd/dd tt:tt Lxx ACC aaaa TRBL-DR LFT OPN +++ ACC aaaa AREA=a POINT=ppp +++ ACC aaaa (text) +++ ACC aaaa (uname) h1rrlssssssaaaasTspppt
[#aaaa|NriaDMppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 197. Door Locked 198. Door Locked (Automatic) 199. Door Locked (Automatic) (points > 254) 200. Door Locked (By Programmer) (points > 254) 201. Door Locked (By Remote) (points > 254) 202. Door Locked (By Sked) (points > 254) 203. Door Locked (By User) 204. Door Locked (By User) (points > 254, users < 255) 205. Door Locked (By User) (points > 254, users > 254) 206. Door Locked (By User, User not identified) (points < 255) 207. Door Locked (By User, User not identified) (points > 254) 208. Door Locked (points > 254) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|NriaDYLpp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ ACC aaaa AUTOMATIC +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|NriaDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/pidddDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/aikkkDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|Nria/idiiiDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/idiiiDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/idiiiiDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|NriaDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 77 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 209. Door Request (Request to Enter) (points > 254) 210. Door Request (Request to Exit) (points > 254) 211. Door Request (REX) 212. Door Request (REX, Denied) (Interlock Deny) 213. Door Request (REX, Denied) (Door Secured) 214. Door Request (RTE) 215. Door Request (RTE, Denied) (Door Secured) (points > 254) 216. Door Request (RTE, Denied) (Interlock Deny) (points > 254) 217. Door Request (RTX, Denied) (Door Secured) (points > 254) 218. Door Request (RTX, Denied) (Interlock Deny) (points > 254) 219. Door Secured 220. Door Secured (Automatic) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDEpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDXpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDXppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ ACC aaaa DENIED-INTERLOCK +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ ACC aaaa DENIED-DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 78 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDEppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ ACC aaaa AUTOMATIC +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|NriaDCppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 221. Door Secured (Automatic) (points > 254) 222. Door Secured (By Programmer) (points > 254) 223. Door Secured (By Remote) (points > 254) 224. Door Secured (By Sked) (points > 254) 225. Door Secured (By User) 226. Door Secured (By User) (points <255, users > 254) 227. Door Secured (By User) (points > 254, users < 255) 228. Door Secured (By User) (points > 254, users > 254) 229. Door Secured (By User, User not identified) (points < 255) 230. Door Secured (By User, User not identified) (points > 254) 231. Door Secured (points > 254) 232. Door Unlocked Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/pidddDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/aikkkDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID-iii POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|Nria/idiiiDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|Nria/idiiiiDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iii POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/idiiiDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/idiiiiDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|NriaDOppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 79 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 233. Door Unlocked (Automatic) 234. Door Unlocked (By User) 235. Door Unlocked (Automatic) (points > 254) 236. Door Unlocked (By Programmer) (points > 254) 237. Door Unlocked (By Remote) (points > 254) 238. Door Unlocked (By Sked) (points > 254) 239. Door Unlocked (By User) (points < 255, users > 254) 240. Door Unlocked (By User) (points > 254, users < 255) 241. Door Unlocked (By User) (points >254, users > 254) 242. Door Unlocked (By User, User not identified) (points > 254) 243. Door Unlocked (By User) (points > 254) 80 Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ ACC aaaa AUTOMATIC +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|NriaDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ ACC aaaa BY USER +++ ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|Nria/idiiiDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/pidddDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/aikkkDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|Nria/idiiiiDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/idiiiDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/idiiiiDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 244. Duress 245. Duress Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: A user with the ID in the second line of the report initiated a duress from a keypad located in the AREA in the second line of the report. 1. D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa DURESS +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasDsiiit
[#aaaa|Nria/idiiiHA] Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt
[#aaaa|NBAz] ALARM ZN z 2, D7112: z=0. D9112: z= as programmed in BFSK Duress Code 246. Duress 247. Duress (Area Not Reported) 248. Duress Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 249. Duress (user > 254) 250. Early Open By Account Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasDssszt
[#aaaa|NHAz] DURESS ID z dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasDsiiit
[#aaaa|NidiiiHA] DURESS ID=iii A user with the ID in the second line of the report initiated a duress from a keypad located in the AREA in the second line of the report. dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasDsiiit
[#aaaa|Nria/idiiiHA] DURESS ID=iii A user with the ID in the second line of the report initiated a duress from a keypad located in the AREA in the second line of the report. dd/dd tt:tt Lxx ACC aaaa DURESS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasDiiiit
[#aaaa|Nriaa/idiiiiHA] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOK] EARLY TO OPEN ID=iii 251. Early Open By Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NOK] EARLY TO OPEN 252. Early Open By Account Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssit
[#aaaa|NOPi] OPENING Zn I dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NOP] OPENING REPORT 253. Early Open By Account (ID not reported) Bosch Security Systems, Inc. | 9/07 | 4998122703-02 A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window. 1, A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window. 1, D7112 D7112 2, 9. System disarmed. A user with the ID in the second line of the report disarmed the AREA. 2, 9. D7112 81 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 254. Early Open By Area (ID not reported) Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NriaOK] 255. Early Open By Area Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 256. Early Open By Area 257. Early To Close (7112 Only) 258. Early To Open (7112 Only) 259. Equipment Fail (Report from UPLINK router indicating ”Transceiver Trouble Condition”) 260. Error 261. Error 262. Error 263. Error 264. Extend Close Time by Area 265. Extend Close Time by Area 266. Extend Close Time by Area (ID not reported) 82 Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: EARLY TO OPEN AREA=a dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOK] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOssszt
[#aaaa|NOPz] OPENING ZN z dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCK] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NOK] CLOSING EARLY dd/dd tt:tt Lxx ACC aaaa EQUIPMENT FAIL Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window. 1, A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window. 1. D7112 2, z = area number EARLY TO OPEN +++ ACC aaaa SDI=255 COND=001 +++ ACC aaaa UPLINK. h1rrlssssssaaaasTsD29t
[#aaaa|Npi255IA001] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN h1rrlssssssaaaas[sssst
[#aaaa|NRT] dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN z h1rrlssssssaaaas[ssszt
[#aaaa|NRTz] dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN zz h1rrlssssssaaaas[sszzt
[#aaaa|NRTzz] dd/dd tt:tt Lxx ACC aaaa [ERROR] ZN zzz h1rrlssssssaaaas[szzzt
[#aaaa|NRTzzz] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ ACC aaaa AREA=a ID=iii TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nria/idiii/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=a TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nria/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ ACC aaaa AREA=a TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nria/tihhmmCE] A user with the ID in the second line of the report extended the closing time of the AREA to the TIME printed. 1. A user with the ID in the second line of the report extended the closing time of the AREA to the TIME printed. 1, D7112 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 267. Extend Close Time by Area (users < 255) 268. Extend Close Time by Area (users > 254) 269. Extra Point Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=a ID=iiii TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nriaa/idiiii/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=aa ID=iiii TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nriaa/idiiii/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTRA POINT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaXEppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 270. Extra Point (points > 254) 271. Extra RF Point Printer: D6500 Mode: SIA Mode: Printer: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. An extra RF POINT in the AREA in the second line of the report was detected. 1, Abnormal RAM session termination or beginning of the Command 58 Fire Test. 2. dd/dd tt:tt Lxx ACC aaaa EXTRA POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaXEpppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasTsD16t
[#aaaa|NpidddXF] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTsD16t
[#aaaa|NriaXF] 273. Fail To Call RAM Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssFt
[#aaaa|NBTF] 274. Fail To Call RAM Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa BAD CALL TO RAM h1rrlssssssaaaasTsF02t
[#aaaa|NRA] Control panel attempted to call RAM and was unsuccessful. 275. Fail To Close by Area Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssEt
[#aaaa|NriaCI] The AREA in the second line of the report was not armed before the programmed closing time. 272. Extra RF Point Detected D6500 Mode: SIA Mode: 276. Fail To Close by Area Printer: D6500 Mode: SIA Mode: 277. Fail To Close, Delinquent 278. Fail To Execute (Door UnlockedInterlock) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssEt
[#aaaa|NriaCI] EXTRA RF POINT SDI=ddd EXTRA RF POINT TROUBLE ZN F FAIL TO CLOSE AREA=a FAIL TO CLOSE AREA=a D7112 The AREA in the second line of the report was not armed before the programmed closing time. dd/dd tt:tt Lxx ACC aaaa DELNQNT CLOSING +++ACC aaaa AREA=a h1rrlssssssaaaasTsssEt
[#aaaa|NriaCD] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR UNLOCKED-INTERLOCK +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaDKppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 83 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 279. Fail to Execute (Door UnlockedInterlock) (points > 254) 280. Fail To Execute (Door UnlockedDoor Secured) 281. Fail To Execute (Door UnlockedDoor Secured) (points > 254) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR UNLOCKED-DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-DOOR SECURE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaaDKpppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 282. Fail To Execute (Door UnlockedDoor Secured) (points > 254) Printer: 283. Fail To Execute (Door UnlockedDoor Secured) (points < 255) Printer: 284. Fail To Execute (Door CycledInterlock) Printer: 285. Fail To Execute (Door CycledInterlock) (points > 254) 286. Fail To Execute (Door CycledDoor Secured) 287. Fail To Execute (SDI Device, Incorrect Response) 288. Fail To Execute (SDI Device, No Response) 289. Fail To Open by Area D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 84 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-DOOR SECURE +++ACC aaaa AREA=aa POINT=ppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR CYCLED-INTERLOCK +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa DOOR CYCLED-DOOR SECURED +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa INCORRECT RESPONSE +++ ACC aaaa SDI=ddd h1rrlssssssaaaasNsD34t
[#aaaa|NpidddYX] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ ACC aaaa NO RESPONSE +++ ACC aaaa SDI=ddd h1rrlssssssaaaasNsD34t
[#aaaa|NpidddYX] dd/dd tt:tt Lxx ACC aaaa FAIL TO OPEN +++ ACC aaaa AREA=a h1rrlssssssaaaasTsssEt
[#aaaa|NriaOI] The AREA in the second line of the report was not disarmed during the programmed opening time window. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation 290. Fail To Call RAM Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa BAD CALL TO RAM h1rrlssssssaaaasTsF02t
[#aaaa|NRA] Control panel attempted to call RAM and was unsuccessful. 291. Fire Alarm Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaFAppp] Alarm signal from the POINT (programmed with a Fire Point code) and the AREA in the second line of the report. Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasFssszt
[#aaaa|NFAz] 293. Fire Alarm (Area Not Reported) Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasFspppt
[#aaaa|NFAppp] 294. Fire Alarm (point < 255) Printer: 292. Fire Alarm FIRE FR z Refer to Section C.1 Zonex and Comex Translation on page 137. 1, 10. 2, 3, 9. 295. Fire Alarm (point < 255) 296. Fire Alarm (point < 255) 297. Fire Alarm (point < 255) 298. Fire Alarm (point < 255) 299. Fire Alarm Cross point (point > 254) 300. Fire Alarm Crossed Point (Area Not Reported) 301. Fire Alarm Smoke (point > 254) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: FIRE ALARM POINT=ppp dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaFMppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa SMOKE DETECTED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaFAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa HIGH TEMPERATURE DETECTED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaKAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa WATER FLOW DETECTED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaSAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaFApppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaFMpppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ ACC aaaa CROSS POINT +++ ACC aaaa POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NFMppp] Alarm signal from the POINT (programmed with a Fire Point code) and the AREA in the second line of the report. Alarm signal from the POINT (programmed with a Fire Point code) and the AREA in the second line of the report. dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa SMOKE DETECTED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaFApppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 85 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 302. Fire Alarm (point > 254) 303. Fire Alarm (point > 254) 304. Fire Cancel (users > 254) 305. Fire Missing Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa HIGH TEMPERATURE DETECTED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaKApppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa WATER FLOW DETECTED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaSApppp] dd/dd tt:tt Lxx ACC aaaa FIRE CANCEL +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaas\iiiit
[#aaaa|Nriaa/idiiiiFC] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The POINT (programmed with a Fire Point code) in the AREA in the second line of the report is missing. 1, D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa MISSING FIRE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaFYppp] Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaGsssszt
[#aaaa|NFTz] Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa MISSING FIRE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaFYpppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFHppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFJppp] 310. Fire Restoral after Alarm Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaHsssszt
[#aaaa|NFRz] 311. Fire Restoral after Alarm Printer: dd/dd tt:tt Lxx ACC aaaa FIRE RESTORAL +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFRppp] The POINT (programmed with a Fire Point code) in the AREA specified in the second line of the report was restored after an alarm, trouble, or missing condition. 1, dd/dd tt:tt Lxx ACC aaaa FIRE RESTORAL +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFRppp] The POINT (programmed with a Fire Point code) in the AREA specified in the second line of the report was restored after an alarm, trouble, or missing condition. 1, 306. Fire Missing TROUBL FR z 10. 2, 3, 9. 307. Fire Missing (points > 254) 308. Fire Restoral (from Fire Alarm) 309. Fire Restoral(from Trouble/Missi ng/Supervision ) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: RESTORAL FR z 2, 3, 9. D6500 Mode: SIA Mode: 312. Fire Restore after Trouble/Missi ng 86 Printer: D6500 Mode: SIA Mode: 10. 10. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 313. Fire Restore after Trouble/Missi ng Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaHsssszt
[#aaaa|NFRz] 314. Fire Restoral From Fire Alarm (no area) Printer: 315. Fire Restoral From Fire Alarm (points > 254) 316. Fire Restoral From Trouble/Missi ng/Supervision 317. Fire Supervision 318. Fire Supervision (points < 255) 319. Fire Supervision (points > 254) 320. Fire Supervision (Water Flow) (points < 255) 321. Fire Supervision (Water Flow) (points > 254) 322. Fire Supervision Restore (points < 255) 323. Fire Supervision Restore (points > 254) 324. Fire Supervision Restore (Water Flow) (points < 255) 325. Fire Supervision Restore (Water Flow) (points > 254) Explanation RESTORALFR z Refer to Section C.1 Zonex and Comex Translation on page 137. 2, 3, 9. D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ACC aaaa POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NFHppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaaFHpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TBL RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaaFJpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFSppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFSppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFWppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFVppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFVpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFVppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFVpppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 87 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 326. Fire Supervision Trouble (points < 255) 327. Fire Supervision Trouble (points > 254) 328. Fire Supervision Trouble (Water Flow) (points < 255) 329. Fire Supervision Trouble (Water Flow) (points > 254) 330. Fire Supervision Trouble Restore (points < 255) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFWppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFWpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFWpppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 331. Fire Supervision Trouble Restore (points > 254) Printer: 332. Fire Supervision Trouble Restore (Water Flow) (points < 255) Printer: 333. Fire Supervision Trouble Restore (Water Flow) (points > 254) Printer: 334. Fire Trouble Printer: 335. Fire Restoral D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Trouble condition from the POINT (programmed with a Fire Point code) in the AREA in the second line of the report. 1, dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFWpppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFQppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaFQpppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFQppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaFQpppp] D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFTppp] Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaHsssszt
[#aaaa|NFRz] Printer: dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaKTppp] RESTORAL FR z 10. 2, 3, 9. 336. Fire Trouble (point < 255) 337. Fire Trouble (point < 255) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 88 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 338. Fire Trouble (point < 255) 339. Fire Trouble (point < 254) 340. Fire Trouble (with Ground Fault) (point > 254) 341. Fire Trouble (point > 254) 342. Fire Trouble (point > 254) 343. Fire Trouble (point > 254) 344. Fire Walk End 345. Fire Walk End 346. Fire Walk Start Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa WATER FLOW DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaSTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaKTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa WATER FLOW DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaSTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE WALK END +++ ACC aaaa AREA=a h1rrlssssssaaaasRsssFt
[#aaaa|NriaFK] dd/dd tt:tt Lxx ACC aaa RESTORAL ZN F h1rrlssssssaaaasRsssFt
[#aaaa|NURF] dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiFI] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN F h1rrlssssssaaaasTsssFt
[#aaaa|NBTF] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 347. Fire Walk Start D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 348. Fire Walk Start Printer: 349. Fire Walk Start (no user) 350. Fire Walk Start (users > 254) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiFI] dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ACC aaaa AREA=a h1rrlssssssaaaasTsssFt
[#aaaa|NriaFI] Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Fire Walk Test ended. D9112 Fire Walk Test begun. D9112 Abnormal RAM session termination or beginning of the Command 58 Fire Test. D9112 Fire Walk Test begun. dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nriaa/idiiiiFI] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 89 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 351. Fire Walk End (no users) 352. Fire Walk End (users > 254) 353. Force Armed Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NriaFK] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. FIRE WALK END AREA=a dd/dd tt:tt Lxx ACC aaaa FIRE WALK END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt
[#aaaa|Nriaa/idiiiiFK] dd/dd tt:tt Lxx ACC aaaa WAS FORCE ARMED h1rrlssssssaaaasWsssst
[#aaaa|NCW] Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. FORCED CLOSE ID=iii A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed. 1, D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCF] 355. Force Close by Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCF] FORCED CLOSE A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed. 1, 356. Force Close by Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed. 1. 357. Force Close Early by Account Printer: dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit h1rrlssssssaaaasWsssst
[#aaaa|NCLi]
[#aaaa|NCW] Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points which were not armed are indicated by a TROUBLE or SHUNTED report. 2, A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. 1. 354. Force Close by Account Printer: D6500 Mode: SIA Mode: 358. Force Close Early by Account 90 Printer: D6500 Mode: SIA Mode: CLOSING ZN I WAS FORCE ARMED dd/dd tt:tt Lxx ACC aaaa F CLOSE EARLY +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] D7112 D7112 I = user id. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 359. Force Close Early by Account (ID not reported) Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NriaCF] F CLOSE EARLY AREA=a 360. Force Close Early by Account Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCF] F CLOSE EARLY ID=iii 361. Force Close Early by Account (ID not reported) Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst h1rrlssssssaaaasWsssst
[#aaaa|NCL]
[#aaaa|NCW] CLOSING REPORT WAS FORCE ARMED Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. 1, A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. 1, The system armed/disarmed with a passcode or COMMAND 1 reporting no User ID (D8112G2 excluded). AREA armed by user with the ID in the second line of the report 2, D7112 D7112 by Account D7112 Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. 362. Force Close Early by Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCF] 363. Forced Close Early by Area Printer: dd/dd tt:tt Lxx ACC aaaa F CLOSE LATE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 9/07 | 4998122703-02 F CLOSE EARLY A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. 1, D7112 1, 91 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 364. Forced Close Early by Area(ID not reported) Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NriaCF] 365. Forced Close Early by Area Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 366. Force Close Late by Account Printer: D6500 Mode: SIA Mode: Explanation F CLOSE EARLY AREA=a dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] dd/dd tt:tt Lxx ACC aaa CLOSING ZN I dd/dd tt:tt Lxx ACC aaa WAS FORCE ARMED h1rrlssssssaaaasCsssit h1rrlssssssaaaasWsssst
[#aaaa|NCLi]
[#aaaa|NCW] 367. Force Close Late by Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCF] F CLOSE LATE 368. Force Close Late by Account Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCF] F CLOSE LATE ID=iii 369. Force Close Late by Account (ID not reported) Printer: 370. Forced Close Early by Area (users > 254) Printer: 371. Force Close Early (7112 Only) 92 D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa CLOSING REPORT dd/dd tt:tt Lxx ACC aaa WAS FORCE ARMED h1rrlssssssaaaasCsssst h1rrlssssssaaaasWsssst
[#aaaa|NCL]
[#aaaa|NCW] A user with the ID in the second line of the report armed the AREA before the programmed closing time while points in the AREA were faulted. Faulted points were not armed. A user with the ID in the second line of the report armed the AREA before the programmed closing time while points in the AREA were faulted. Faulted points were not armed. Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. Unexpanded reporting, system armed by arm/disarm passcode or COMMAND 1 (D8112G2 excluded). Unexpanded reporting, system armed by arm/disarm passcode or CMD 1. AREA armed by user with the ID in the second line of the report Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. Refer to Section C.1 Zonex and Comex Translation on page 137. 1, D7112 2, i = user id. 1, D7112 1, D7112 2, D7112 dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY h1rrlssssssaaaasCsssst
[#aaaa|NCF] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 372. Force Close Late (7112 Only) 373. Forced Close Late by Area Device/Mode Display Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE h1rrlssssssaaaasCsssst
[#aaaa|NCF] dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] D6500 Mode: SIA Mode: 374. Forced Close Late by Area (users > 254) 375. Forced Close Perimeter Delay by Area (ID not reported) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaNF] Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. A user with the ID in the second line of the report armed the AREA in the second line of the report after the programmed closing time while points in the AREA were faulted. Faulted points were not armed. A user with the ID in the second line of the report has delay armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed. 1, D7112 376. Forced Close Perimeter Delay by Area (ID not reported) Printer: 377. Forced Close Perimeter Delay by Area (User ID# > 254 reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNF] 378. Forced Close Perimeter instant by Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiNF] A user with the ID in the second line of the report armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed. 1, 379. Forced Close Perimeter instant by Area(ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST h1rrlssssssaaaasCsssst
[#aaaa|NriaNF] A user with the ID in the second line of the report armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed. 1. 380. Forced Close Perimeter Instant by Area (User ID# > 254 reported) Printer: dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNF] D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaNF] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 A user with the ID in the second line of the report armed the perimeter of the AREA while points in the AREA were faulted. Faulted points were not armed. D7112 93 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 381. Force Closing by Account Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssit h1rrlssssssaaaasWsssst
[#aaaa|NCLi]
[#aaaa|NCW] CLOSING ZN I WAS FORCE ARMED dd/dd tt:tt Lxx ACC aaa dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasCsssst h1rrlssssssaaaasWsssst
[#aaaa|NCL]
[#aaaa|NCW] CLOSING REPORT WAS FORCE ARMED D6500 Mode: SIA Mode: 382. Force Closing by Account (ID not reported) Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. 2, The system armed/disarmed with a passcode or COMMAND 1 reporting no User ID (D8112G2 excluded). AREA armed by user with the ID in the second line of the report 2, I = user id. D7112 Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. 383. Forced Closing by Area Printer: D6500 Mode: SIA Mode: 384. Forced Closing by Area Printer: D6500 Mode: SIA Mode: 385. Forced Closing by Area (no area) (users <255) 386. Forced Closing by Area (users > 254) 387. Forced Point Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 94 dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiNF] A user with the ID in the second line of the report armed the AREA while points in the AREA were faulted. Faulted points were not armed. dd/dd tt:tt Lxx ACC aaa CLOSING ZN z dd/dd tt:tt Lxx ACC aaa WAS FORCE ARMED h1rrlssssssaaaasCssszt h1rrlssssssaaaasWsssst
[#aaaa|NCLz]
[#aaaa|NCW] Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. 2, The POINT in the AREA in the second line of the report was faulted and bypassed when the system was armed. 10, dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ACC aaaa ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCF] dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ ACC aaaa AREA=a POINT=ppp ID=iii h1rrlssssssaaaasTspppt
[#aaaa|Nria/idiiiXWppp] z = area number D7112 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 388. Forced Point Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaXWppp] The POINT in the AREA in the second line of the report was faulted and bypassed when the system was armed. 1, dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaXWppp] The POINT in the AREA in the second line of the report was faulted and bypassed when the system was armed. 1, D6500 Mode: SIA Mode: 389. Forced Point (ID not reported) 390. Forced Point 391. Forced Point (point > 254) 392. Invalid Local Access Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 393. Invalid Remote Access 394. Invalid Remote Access (phone not reported) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaXWpppp] dd/dd tt:tt Lxx ACC aaaa PROG ACCESS BAD +++ ACC aaaa SDI=ddd h1rrlssssssaaaasTsF01t
[#aaaa|NpidddLU] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN F h1rrlssssssaaaasTsssFt
[#aaaa|NBTF] dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL +++ ACC aaaa PHONE#=5 h1rrlssssssaaaasTsssFt
[#aaaa|Nph5RU] 395. Invalid Remote Access (from Call Back) Printer: 396. Invalid Remote Access (no call back) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt
[#aaaa|NpRU] 397. Invalid Remote Access Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt
[#aaaa|NphhRU] 398. Invalid Remote Access Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt
[#aaaa|NRU] 399. Invalid Report Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlsssssssssssXss26t
[#aaaa|NYN] D6500 Mode: SIA Mode: 6, D9112 6, D7112 9. An unsuccessful attempt was made to locally access the account through the supervised keypad or other serial device specified in the second line of the report. Abnormal RAM session termination or beginning of the Command 58 Fire Test. An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. D9112 2. D9112 dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL +++ACC aaaa PH#=hh h1rrlssssssaaaasTsssFt
[#aaaa|NphhhRU] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. D9112 D7112 INVALID REPORT 95 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOJ] 401. Late Opening By Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NOJ] 402. Late Opening By Area Printer: 400. Late Opening By Account D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. LATE TO OPEN ID=iii A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window. 1. LATE TO OPEN A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window. 1, dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOJ] A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window. 1, LATE TO OPEN AREA=a A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window. 1, CLOSING LATE 403. Late Opening By Area (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NriaOJ] 404. Late To Close (7112 Only) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasCsssst
[#aaaa|NCJ] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NOJ] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas*sssst
[#aaaa|NLF] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaas*sssst
[#aaaa|NLF] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTsD01t
[#aaaa|NJL] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa LOG OVERFLOW h1rrlssssssaaaasAsD01t
[#aaaa|NJO] +++ ACC aaaa LOG OVERFLOW h1rrlssssssaaaaSLsssst
[#aaaa|OJO] Printer: D6500 Mode: SIA Mode: +++ ACC aaaa h1rrlssssssaaaaSBsssst
[#aaaa|OJL] 405. Late To Open (7112 Only) 406. Listen In 407. Listen In 408. Log Threshold 409. Log Overflow 410. Log Overflow Since Last Call 411. Log Threshold Since Last Call 96 D7112 D7112 D7112 LATE TO OPEN LISTEN IN LISTEN jj LOG THRESHOLD LOG THRESHOLD The log in the control panel reached the programmed percent full point programmed in item Log % Full (default Log Full = 85%). The log in the control panel reached the programmed percent full point programmed in item Log % Full (default Log Full = 85%). 5. 5. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 412. Low Battery 413. Low Temperature (points < 255) 414. Low Temperature (points > 254) 415. Low Temperature Restore (points < 255) 416. Low Temperature Restore (points > 254) 417. Missing Alarm Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt LOW BATTERY RCVR rr h1rrssssssssssssXss11t
[NYT] dd/dd tt:tt Lxx ACC aaaa LOW TEMPERATURE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasLspppt
[#aaaa|NriaZAppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMPERATURE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasLppppt
[#aaaa|NriaaZApppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMP RESTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRLspppt
[#aaaa|NriaZRppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMP RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRLppppt
[#aaaa|NriaaZRpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaUZppp] The POINT in the AREA specified in the second line of the report is missing. 1, D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 418. Missing Alarm 419. Missing Alarm (Area Not Reported) 420. Missing Alarm Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 421. Missing Alarm (points > 254) 422. Missing Alarm - Cross Point (points < 255) 423. Missing Alarm - Cross Point (points > 254) 424. Missing Alarm with Recent Closing Created due to alarm within 5 min of close (points > 254, users <255) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt
[#aaaa|NBAz] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasMspppt
[#aaaa|NUZppp] ALARM ZN z 10. 2, 9. MISSING ALARM POINT=ppp The POINT in the AREA specified in the second line of the report is missing. dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaUZppp] The POINT in the AREA specified in the second line of the report is missing. dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaXMppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaXMpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiCMpppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 97 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 425. Missing Alarm with Recent Closing Created due to alarm within 5 min of close (points > 254, users >254) Printer: dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiiCMpppp] 426. Missing Alarm - Exit Error (points > 254, users < 255) Printer: 427. Missing Alarm - Exit Error (points > 254, users > 254) 428. Missing Fire Supervision 429. Missing Fire Supervision (points < 255) 430. Missing Fire Supervision (points > 254) 431. Missing Fire Supervision (points > 254) 432. Missing Supervision 433. Missing Supervision (points > 254) 434. Missing Tbl 435. Missing Trouble 436. Missing Trouble D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 98 Explanation dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiEZpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiiEZpppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGMspppt
[#aaaa|NriaFZppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGMspppt
[#aaaa|NriaFZppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGMppppt
[#aaaa|NriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGMppppt
[#aaaa|NriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa MISSING SUPRVSN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaMTspppt
[#aaaa|NriaBZppp] dd/dd tt:tt Lxx ACC aaaa MISSING SUPRVSN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaMTppppt
[#aaaa|NriaaBZpppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE* ZN zyy h1rrlssssssaaaasVszyyt
[#aaaa|NUYzyy] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasVspppt
[#aaaa|NriaUYppp] Refer to Section C.1 Zonex and Comex Translation on page 137. 2. Trouble condition received from the POINT (programmed with a Fire Point code) in the AREA in the second line of the report. 1, 10. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation 437. Missing Trouble (Area Not Reported) Printer: dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ ACC aaaa POINT=ppp h1rrlssssssaaaasVspppt
[#aaaa|NUYppp] Trouble condition received from the POINT (programmed with a Fire Point code) in the AREA in the second line of the report. 438. Missing Trouble (for use with Keyfob device) (points < 255) Printer: 439. Missing Trouble (points < 255) 440. Missing Trouble (for use with Keyfob device) (points > 254) 441. Missing Trouble (points > 254) 442. MPU Version 443. No Entry (Door Secured) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 444. No Entry (Interlock Deny) Printer: 445. No Entry (points < 255, user < 255) (AntiPassback) Printer: 446. No Entry (points > 254, users < 254) (Wrong Arming State) Printer: 447. No Entry (point > 254, users < 255) (AntiPassback) Printer: 448. No Entry (points > 254, users < 255) (Door Secured) Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasVsD10t
[#aaaa|NidiiiUY] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasVspppt
[#aaaa|NriaUYppp] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasVspppt
[#aaaa|NriaUYppp] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasVppppt
[#aaaa|NriaaUYpppp] dd/dd tt:tt 6500 MPU vv.vv RCVR rr h3rrs 6500 MPU vv.vvt
[A6500 MPU vv.vv] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDZppp] or
[#aaaa|Nria/idiii/ssxDZppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDWppp] or
[#aaaa|Nria/idiii/ssxDWppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDIppp] or
[#aaaa|Nria/idii/ssxDIpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDQpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDIppp] or
[#aaaa|Nriaa/idiii/ssxDIpppp] The Modifier “/ssx” refers to the Data Type Address, not the Modifiers “idiii,” or “piddd” dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDZpppp] or
[#aaaa|Nriaa/idiii/ssxDZpppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 99 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 449. No Entry (points > 254, users < 255) (Interlock Deny) Printer: 450. No Entry (points > 254, users < 255) (No Rights in Area) Printer: dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDWpppp] or
[#aaaa|Nriaa/idiii/ssxDWpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDVpppp] 451. No Entry (points > 254, users < 255) (Outside Time Window) Printer: 452. No Entry (points > 254, users > 254) (AntiPassback) Printer: 453. No Entry (points > 254, users > 254) (Door Secured) Printer: 454. No Entry (points > 254, users > 254) (Interlock Deny) Printer: 455. No Entry (points > 254, users > 254) (No Rights in Area) Printer: 456. No Entry (points > 254, users > 254) (Wrong Arming State) Printer: 457. No Entry (points > 254, users > 254) (Outside Time Window) Printer: 458. No Entry (No Rights in Area) Printer: 459. No Entry (Outside Time Window) Printer: 460. No Entry (Unknown ID) Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 100 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDPpppp] or
[#aaaa|Nriaa/idiii/ssxDPpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDIppp] or
[#aaaa|Nriaa/idiii/ssxDIpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDZpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDWpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDVpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDQpppp] or
[#aaaa|Nriaa/idiii/ssxDQpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDPpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDVppp] or
[#aaaa|Nria/idiii/ssxDVppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDPppp] or
[#aaaa|Nria/idiii/ssxDPppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-UNK ID +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDDppp] or
[#aaaa|Nria/idiii/ssxDDppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 461. No Entry (Wrong Arming State) Printer: 462. Opening Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDQppp] or
[#aaaa|Nria/idiii/ssxDQppp] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT h1rrlssssssaaaasOsssst
[#aaaa|NOP] dd/dd tt:tt Lxx ACC aaaa OPENING ZN I h1rrlssssssaaaasOsssit
[#aaaa|NOPi] dd/dd tt:tt Lxx ACC aaaa OPENING ID I h1rrlssssssaaaasOsssit
[#aaaa|NOPi] dd/dd tt:tt Lxx ACC aaaa OPENING ID iyy h1rrlssssssaaaasOsiyyt
[#aaaa|NOPiyy] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOP] Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasOsssst
[#aaaa|NOP] OPENING REPORT 468. Opening By Account (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasOsssst
[#aaaa|NOP] OPENING REPORT 469. Opening By Account Printer: D6500 Mode: SIA Mode: Printer: 463. Opening 464. Opening 465. Opening 466. Opening By Account 467. Opening By Account 470. Opening By Account D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 471. Opening by Account from Alarm 472. Opening By Area Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 473. Opening By Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasOsssit
[#aaaa|NOPi] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOP] Explanation System disarmed. A user with the ID in the second line of the report disarmed the AREA. System disarmed. A user with the ID in the second line of the report disarmed the AREA. 1. System disarmed. A user with the ID in the second line of the report disarmed the AREA. 1, System disarmed. A user with the ID in the second line of the report disarmed the AREA. 2, OPENING ZN I D7112 9, D7112 2, 9. OPENING REPORT ID=iii dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ ACC aaaa ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOR] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOP] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOP] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Refer to Section C.1 Zonex and Comex Translation on page 137. System disarmed. A user with the ID in the second line of the report disarmed the AREA. System disarmed. A user with the ID in the second line of the report disarmed the AREA. System disarmed. A user with the ID in the second line of the report disarmed the AREA. 1. 101 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 474. Opening by Area 475. Opening By Area (ID not reported) 476. Opening by Area (users > 254) 477. Opening by Area (users < 255) 478. Opening by Area from Alarm 479. Opening by Area from Alarm (users > 254) 480. Opening Early by Area Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa| NriaOP] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NriaOP] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 481. Opening Early by Area 482. Opening Early by Area (users > 254) 483. Opening Early by Area from Alarm 484. Opening Early by Area from Alarm (users > 254) 485. Opening Late by Area Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 486. Opening Late by Area Printer: D6500 Mode: SIA Mode: 102 Refer to Section C.1 Zonex and Comex Translation on page 137. System disarmed. A user with the ID in the second line of the report disarmed the AREA. 1, OPENING REPORT AREA=a OPENING REPORT AREA=a dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOP] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa AREA=aa ID=iii h1rrlssssssaaaasOiiit
[#aaaa|Nriaa/idiiiOP] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOR] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOR] dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOK] dd/dd tt:tt Lxx ACC aaaa EARLY +++ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NriaOK] dd/dd tt:tt Lxx ACC aaaa EARLY +++ACC aaaa AREA=aa h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOK] dd/dd tt:tt Lxx ACC aaaa OP ERLY +++ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NriaOH] dd/dd tt:tt Lxx ACC aaaa OP ERLY +++ACC aaaa AREA=aa h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOH] dd/dd tt:tt Lxx ACC aaaa LATE +++ ACC aaaa AREA=a h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOJ] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasOsssst
[#aaaa|NriaOJ] Explanation D7112. A user with the ID in the second line of the report disarmed the AREA before the programmed opening time window. TO OPEN AREA=a TO OPEN ID=iiii FRM-ALM AREA=a FRM-ALM ID=iiii TO OPEN ID=iii A user with the ID in the second line of the report disarmed the AREA after the programmed opening time window. LATE TO OPEN AREA=a Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 487. Opening Late by Area (users > 254) 488. Opening Late by Area from Alarm 489. Opening Late by Area from Alarm (users > 254) 490. Output State (outputs < 255) 491. Output State (outputs > 254) 492. Output State Restore (outputs < 255) 493. Output State Restore (outputs > 254) 494. Paper In 495. Paper Out 496. Parameters Changed 497. Parameter Checksum Fail 498. Parameter Checksum Fail 499. Parameter Checksum Fail (SDI Device and Point reported) 500. Parameters Checksum Fail Since Last Call 501. Perimeter Delay (Area Not Reported) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOJ] dd/dd tt:tt Lxx ACC aaaa OP LATE FRM-ALM +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOL] dd/dd tt:tt Lxx ACC aaaa OP LATE FRM-ALM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOL] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TROUBLE +++ACC aaaa OUTPUT=uuu h1rrlssssssaaaasTsD47t
[#aaaa|NOUuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TROUBLE +++ACC aaaa OUTPUT=uuuu h1rrlssssssaaaasTsD47t
[#aaaa|NOUuuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TRBL RST +++ACC aaaa OUTPUT=uuu h1rrlssssssaaaasRsD47t
[#aaaa|NOVuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TRBL RST +++ACC aaaa OUTPUT=uuuu h1rrlssssssaaaasRsD47t
[#aaaa|NOVuuuu] dd/dd tt:tt PAPER IN RCVR rr h1rrssssssssssssXss15t
[NVI] dd/dd tt:tt PAPER OUT RCVR rr h1rrssssssssssssXss16t
[NVO] dd/dd tt:tt Lxx ACC aaaa PARAMS CHANGED h1rrlssssssaaaasNsD02t
[#aaaa|NYG] dd/dd tt:tt Lxx ACC aaaa PARM CKSUM FAIL h1rrlssssssaaaasTsD15t
[#aaaa|NYF] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The program in the control panel parameters is corrupt. Send service immediately. D9112 dd/dd tt:tt Lxx ACC aaaa PARMS BAD CKSUM h1rrlssssssaaaasTsD15t
[#aaaa|NYF] dd/dd tt:tt Lxx ACC aaaa PARMS BAD CKSUM +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasTspppt
[#aaaa|NpidddYFppp] +++ ACC aaaa PARAMS BAD CKSM h1rrlssssssaaaaSMsssst
[#aaaa|OYF] dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ ACC aaaa ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiNL] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 5. A user with the ID in the second line of the report delay armed the perimeter of the AREA. 103 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 502. Perimeter Delay by Area Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiNL] A user with the ID in the second line of the report delay armed the perimeter of the AREA. 1. dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaNL] A user with the ID in the second line of the report delay armed the perimeter of the AREA. 1, D6500 Mode: SIA Mode: 503. Perimeter Delay by Area (ID not reported) Printer: 504. Perimeter Delay by Area (User ID# > 254 reported) Printer: 505. Perimeter Delay by Area, User Defined (User Defined ID# > 254 reported) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 506. Perimeter Instant (Area Not Reported) Printer: 507. Perimeter Instant by Area Printer: 508. Perimeter Instant by Area (ID not reported) Printer: 509. Perimeter Instant by Area (ID not reported) Printer: 510. Perimeter Instant by Area (User ID# > 254 reported) Printer: 511. Perimeter Instant by Area, User Defined (User ID# > 254 reported) Printer: 512. Phone Line Fail (Line 1) Printer: 513. Phone Line 1 Fail 104 D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D7112 dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNL] dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ACC aaaa USER DEFINED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNM] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiNL] A user with the ID in the second line of the report armed the perimeter of the AREA. dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiNL] A user with the ID in the second line of the report armed the perimeter of the AREA. 1. dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa ID=ii h1rrlssssssaaaasCsssst
[#aaaa|NriaNL] A user with the ID in the second line of the report armed the perimeter of the AREA. 1, dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaNL] A user with the ID in the second line of the report armed the perimeter of the AREA. D7112 dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNL] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa USER DEFINED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNM] PHONE LINE FAIL PHONE LINE=1 The premises phone line in the second line of the report does not operate. D7112 D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssBt
[#aaaa|NLT1] Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssBt
[#aaaa|NBTB] TROUBLE Primary Phone Line failure (two-line system). 2. ZN B Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 514. Phone Line 2 Fail Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssCt
[#aaaa|NBTC] TROUBLE Secondary Phone Line failure (two-line system). 2. 515. Phone Line Fail (Line 2) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssCt
[#aaaa|NLT2] PHONE LINE FAIL PHONE LINE=2 The premises phone line in the second line of the report does not operate. D7112 516. Phone Line 1 Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRsssBt
[#aaaa|NURB] RESTORAL ZN Primary Phone Line is restored (two line system). 2. 517. Phone Line Restoral (Line 1) Printer: PHONE RESTORAL PHONE LINE=1 The premises line in the second line of the report is restored. D7112 D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssBt
[#aaaa|NLR1] 518. Phone Line 2 Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRsssCt
[#aaaa|NURC] Secondary Phone Line is restored (two line system). 2. 519. Phone Line 2 Restoral (Line2) Printer: The premises line in the second line of the report is restored. D7112 D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa PHONE RESTORAL +++ ACC aaaa PHONE LINE=2 h1rrlssssssaaaasRsssCt
[#aaaa|NLR2] dd/dd tt:tt Lxx PHONE RESTORED RCVR rr h1rrlsssssssssssXsss6t
[NLR dd/dd tt:tt Lxx PHONE TROUBLED RCVR rr h1rrlsssssssssssXsss5t
[NLT] dd/dd tt:tt Lxx ACC aaaa PT BUS TROUBLE h1rrlssssssaaaasTsssDt
[#aaaa|NET] 523. Point Bus Fail Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssDt
[#aaaa|NBTD] Zonex service required message: indicates a trouble condition on the data lines wiring from the POPEX Module to the POPITs. Trouble on wiring connecting control panel and keypads. Point bus, supervised keypad, printer, or other serial device trouble. 2. 524. Point Bus Fail (area reported) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa PT BUS TROUBLE +++ACC aaaa AREA=aa h1rrlssssssaaaasTsssDt
[#aaaa|NriaaET] +++ ACC aaaa PT BUS TROUBLE h1rrlssssssaaaaSTsssst
[#aaaa|OET] Trouble on the data line for the points or keypads. 5. Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa PT BUS RESTORAL h1rrlssssssaaaasRsssDt
[#aaaa|NER] 520. Phone Restored 521. Phone Troubled 522. Point Bus Fail 525. Point Bus Fail Since Last Call 526. Point Bus Restoral Bosch Security Systems, Inc. | 9/07 | 4998122703-02 RESTORAL TROUBLE ZN ZN ZN C B C D Trouble on the data line for the points or keypads. Data line for the points or keypads restored. 105 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 527. Point Bus Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRsssDt
[#aaaa|NURD] 528. Point Bus Restoral (area reported) Printer: dd/dd tt:tt Lxx ACC aaaa PT BUS RESTORAL +++ACC aaaa AREA=aa h1rrlssssssaaaasRsssDt
[#aaaa|NriaaER] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ ACC aaaa AREA=a POINT=ppp ID=iii h1rrlssssssaaaasNspppt
[#aaaa|Nria/idiiiUBppp] 529. Point Bypass D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 530. Point Bypass 531. Point Bypass (Area and ID Not Reported) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 532. Point Bypass (ID not reported) Printer: 533. Point Bypass (point < 255) Printer: 534. Point Bypass (point < 255) (fire point) 535. Point Bypass (point > 254) (fire point) 536. Point Bypass (point < 255) (supervisory point) 106 D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: RESTORAL ZN D dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ ACC aaaa POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NUBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Zonex restoral message: indicates a trouble condition on the wiring from the POPEX Module to the POPITs was cleared. Wiring connecting the control panel and keypads restored. Point bus, supervised keypad, printer, or other serial device was restored. 2. The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by the user with the specified ID. 1, D7112 9, D7112 The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by the user with the specified ID. The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by the user with the specified ID. 1, D7112 dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa FIRE POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaFBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa FIRE POINT +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaFBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaSBppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 537. Point Bypass (point > 254) (supervisory point) 538. Point Bypass (point < 255) (waterflow point) 539. Point Bypass (point > 254) (waterflow point) 540. Point Bypass (point > 254) 541. Point Closing Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaSBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaWBppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 542. Point Closing (points > 254) 543. Point Opening Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 544. Point Opening (points > 254) 545. Point Text 546. Power Fail 547. Programmer Bypass Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The POINT in the AREA in the second line of the report was armed. 1, The POINT in the AREA in the second line of the report was armed. 1, dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaWBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa POINT CLOSING +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasCspppt
[#aaaa|NriaCZppp] 10. dd/dd tt:tt Lxx ACC aaaa POINT CLOSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasCppppt
[#aaaa|NriaaCZpppp] dd/dd tt:tt Lxx ACC aaaa POINT OPENING +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasOspppt
[#aaaa|NriaOZppp] 10. dd/dd tt:tt Lxx ACC aaaa POINT OPENING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasOppppt
[#aaaa|NriaaOZpppp] +++ ACC aaaa (point text) no message no message dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasPsssst
[#aaaa|NAT] D9112 AC FAILED dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt
[#aaaa|Nria/pidddUBppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 No AC power. Control panel is running on battery power only. This report is sent along with the next report transmitted. It is not transmitted independently. The POINT in the AREA in the second line of the report is faulted, and was bypassed by a programmer with the specified serial device number when the system was armed. 1, D9112 107 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 548. Programmer Bypass 549. Printer Off Line 550. Printer On Line 551. Printer Restoral 552. Printer Status – Off Line 553. Printer Status – On Line 554. Printer – Paper In 555. Printer – Paper Out 556. Printer Trouble 557. Printer Version 558. Programmer Bypass (point > 254) 559. Programmer In 560. Programmer Out 561. Pulse Error 562. RAM Access Fail (Call Back) 108 Device/Mode Display Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] dd/dd tt:tt PRINTER OFFLINE RCVR rr h1rrssssssssssssXss20t
[NVZ] dd/dd tt:tt PRINTER ONLINE RCVR rr h1rrssssssssssssXss19t
[NVY] dd/dd tt:tt PRINTER RESTORAL RCVR rr h1rrssssssssssssXss22t
[NVR] dd/dd tt:tt Lxx ACC aaaa PRINTR-OFF LINE +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVZ] dd/dd tt:tt Lxx ACC aaaa PRINTER-ON LINE +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVY] dd/dd tt:tt Lxx ACC aaaa PRINTR-PAPER IN +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVI] dd/dd tt:tt Lxx ACC aaaa PRNTR-PAPER OUT +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVO] dd/dd tt:tt PRINTER TROUBLE RCVR rr h1rrssssssssssssXss21t
[NVT] dd/dd tt:tt PRINTER vv.vv RCVR rr h3rrs PRINTER vv.vvt
[APRINTER vv.vv] dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/pidddUBpppp] dd/dd tt:tt PROGRAM MODE IN RCVR rr h1rrssssssssssssXss17t
[NLB] dd/dd tt:tt PROGRAM MODE OUT RCVR rr h1rrssssssssssssXss18t
[NLD] dd/dd tt:tt Lxx PULSE ERROR # ## RCVR rr h3rrlPULSE ERROR # ##t
[APULSE ERROR # ##] dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL h1rrlssssssaaaasTsssFt
[#aaaa|NRU] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 9, D9112 An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation 563. RAM Access Fail (No Call Back) Printer: dd/dd tt:tt Lxx ACC aaaa RAM ACCESS FAIL +++ ACC aaaa PHONE#=h h1rrlssssssaaaasTsssFt
[#aaaa|NphhRU] An unsuccessful attempt was made by a RAM to contact the account on the PHONE# specified in the second line of the report. 564. RAM Access OK (from Call Back) Printer: RAM ACCESS OK PHONE#=h D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NphhRS] The account was contacted by a RAM on the PHONE# specified in the second line of the report. 565. RAM Access OK (via Phone Line) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NRS] RAM ACCESS OK The account was contacted by a RAM on the PHONE# specified in the second line of the report. 566. Re-Boot Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RE-BOOT h1rrlssssssaaaasNsD14t
[#aaaa|NRR] dd/dd tt:tt Lxx ACC aaa RESTORAL ZN 9 h1rrlssssssaaaasRsss9t
[#aaaa|NUR9] The control panel was reset. 567. Re-Boot D6500 Mode: SIA Mode: Battery restoral report, control panel reboot, watchdog reset, power reset, or ResetBye with RAM. Refer to Section C.1 Zonex and Comex Translation on page 137. 2, D9112 Control panel reboot, watchdog reset, power reset, or ResetBye with RAM (can also be Battery Restoral Report for D7112). 568. Re-Boot (SDI Device and Point reported) Printer: 569. Reject Command Printer: D6500 Mode: SIA Mode: 570. Relay Reset (by Programmer) Printer: 571. Relay Reset (by RAM) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 572. Relay Reset (by SKED) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RE-BOOT +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt
[#aaaa|NpidddRRppp] dd/dd tt:tt REJECT COMMAND RCVR rr h3rrsREJECT COMMANDsst [REJECT COMMAND] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY PROGRAMMER +++ ACC aaaa RELAY#=rrr SDI=ddd h1rrlssssssaaaasNsD22t
[#aaaa|NpidddROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY REMOTE +++ ACC aaaa RELAY#=rrr h1rrlssssssaaaasNsD24t
[#aaaa|NROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY SKED +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD20t
[#aaaa|NaikkROrrr] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 The control panel was reset. The RELAY specified in the second line of the report was reset. The RELAY specified in the second line of the report was reset. The RELAY specified in the second line of the report was reset. 109 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 573. Relay Reset (by USER) 574. Relay Reset (relay <255, user > 254) (by USER) 575. Relay Reset (relay > 254) (by SKED) 576. Relay Reset (relay > 254) (by Programmer) 577. Relay Reset (relay > 254) (by RAM) 578. Relay Reset (relay >254, user < 255) (by USER) 579. Relay Reset (relay >254, user > 254) (by USER) 580. Relay Reset by Sked 581. Relay Reset by User Device/Mode Display Explanation Printer: dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa BY USER +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiROrrr] The RELAY specified in the second line of the report was reset. D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 582. Relay Set (by Programmer) 583. Relay Set (by RAM) 584. Relay Set (by SKED) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 110 dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiiROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrrr SKED=kkk h1rrlssssssaaaasNsD20t
[#aaaa|NaikkkROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrrr SDI=ddd h1rrlssssssaaaasNsD22t
[#aaaa|NpidddROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrrr h1rrlssssssaaaasNsD24t
[#aaaa|NROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiiROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD20t
[#aaaa|NaikkROrrr] Refer to Section C.1 Zonex and Comex Translation on page 137. The RELAY specified in the second line of the report was reset. 7, dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiROrrr] The RELAY specified in the second line of the report was reset. 1, dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa BY PROGRAMMER +++ ACC aaaa RELAY#=rrr SDI=ddd h1rrlssssssaaaasNsD21t
[#aaaa|NpidddRCrrr] The RELAY specified in the second line of the report was set. dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsD23t
[#aaaa|NRCrrr] RELAY SET BY REMOTE RELAY#=rrr The RELAY specified in the second line of the report was set. dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa BY SKED +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD19t
[#aaaa|NaikkRCrrr] The RELAY specified in the second line of the report was set. D9112 7, D9112 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 585. Relay Set (by USER) 586. Relay Set (relay <255, user > 254) (by USER) 587. Relay Set (relay > 254) (by Programmer) 588. Relay Set (relay > 254) (by RAM) 589. Relay Set (relay > 254) (by SKED) 590. Relay Set (relay >254, user < 255) (by USER) 591. Relay Set (relay >254, user > 254) (by USER) 592. Relay Set by Sked 593. Relay Set by User Device/Mode Display Explanation Printer: dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa BY USER +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiRCrrr] The RELAY specified in the second line of the report was set. D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 594. Remote Bypass Printer: D6500 Mode: SIA Mode: 595. Remote Bypass 596. Remote Bypass (Call back) (point > 254) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiiRCrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrrr SDI=ddd h1rrlssssssaaaasNsD21t
[#aaaa|NpidddRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrrr h1rrlssssssaaaasNsD23t
[#aaaa|NRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrrr SKED=kkk h1rrlssssssaaaasNsD19t
[#aaaa|NaikkkRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa RELAY#=rrr SKED=kk h1rrlssssssaaaasNsD19t
[#aaaa|NaikkRCrrr] Refer to Section C.1 Zonex and Comex Translation on page 137. The RELAY specified in the second line of the report was set. 7, dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiRCrrr] The RELAY specified in the second line of the report was set. 1, dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ ACC aaaa AREA=a POINT=ppp PHONE#=h h1rrlssssssaaaasNspppt
[#aaaa|Nria/phhUBppp] The POINT in the AREA specified in the second line of the report is faulted, and was bypassed by a RAM through through the specified phone line. dd/dd tt:tt Lxx ACC aaa TROUBLE 7, D9112 ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=aa POINT=pppp PH#=hh h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/phhhUBpppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 D9112 1, D9112 9, D9112 111 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: 598. Remote Reset D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa REMOTE RESET h1rrlssssssaaaasNsD11t
[#aaaa|NRN] The control panel power was reset using RAM. D9112 599. Remote Reset Printer: dd/dd tt:tt Lxx ACC aaa RESTORAL D9112 D6500 Mode: SIA Mode: h1rrlssssssaaaasRsss9t
[#aaaa|NUR9] Battery restoral report, control panel reboot, watchdog reset, power reset, or ResetBye with RAM, control panel reboot, watchdog reset, power reset, or ResetBye with RAM (can also be battery restoral report for D7112). 600. Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT h1rrlssssssaaaasRsssst
[#aaaa|NUR] 601. Restoral Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRssszt
[#aaaa|NURz] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRszyyt
[#aaaa|NURzyy] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRssxxt
[#aaaa|NURxx] dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRss16t
[#aaaa|NUR16] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRspppt
[#aaaa|NBRppp] 597. Remote Bypass (No Call back) (point > 254) 602. Restoral 603. Restoral 604. Restoral 605. Restoral (Area Not Reported) D6500 Mode: SIA Mode: 606. Restoral (From Trouble, Missing, NonFire Supervision) Printer: 607. Restoral Fire Printer: D6500 Mode: SIA Mode: Printer: 608. Restoral from Alarm D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 112 ZN RESTORAL ZN 9 Unexpanded restoral report. Command 41. The POINT in the AREA in the second line of the report was restored. z 2, 9. RESTORAL ZN zyy RESTORAL ZN xx RESTORAL ZN 16 RESTORAL REPORT POINT=ppp Unexpanded restoral report. Command 41. The POINT in the AREA in the second line of the report was restored. dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaBRppp] Unexpanded restoral report. Command 41. The POINT in the AREA in the second line of the report was restored. dd/dd tt:tt Lxx ACC aaaa RESTORAL FR z h1rrlssssssaaaaHsssszt
[#aaaa|NFRz] dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaBHppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 609. Restoral from Alarm (no area) 610. Restoral from Alarm (points > 254) 611. Restoral (user < 255) (for use with Keyfob device) (from trouble, missing, nonfire supervision) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NBHppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 612. Restoral (points > 254) (from trouble, missing, nonfire supervision) Printer: 613. RF Battery Restore (Area Not Reported) Printer: D6500 Mode: SIA Mode: Explanation dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaBHpppp] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasRsD10t
[#aaaa|NidiiiUR] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaBRpppp] D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NXRppp] The RF POINT transmitter in the AREA in the second line of the report was restored from a low battery 614. RF Interference Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RF INTERFERENCE h1rrlssssssaaaasTsD08t
[#aaaa|NET] RF interference was detected in premises RF system. 615. RF Low Battery (Area Not Reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTspppt
[#aaaa|NXTppp] The RF POINT transmitter in the AREA in the second line of the report has a low battery. 616. RF Receiver Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RF RCVR RESTORE h1rrlssssssaaaasRsD17t
[#aaaa|NER] 617. RF Receiver Restoral from Trouble Printer: dd/dd tt:tt Lxx ACC aaaa RCVR TBL RESTOR +++ ACC aaaa SDI=ddd h1rrlssssssaaaasRsD17t
[#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa RCVR TAMPER +++ ACC aaaa SDI=ddd h1rrlssssssaaaasXss35t
[#aaaa|NpidddXS] dd/dd tt:tt Lxx ACC aaaa RCVR TAMPR REST +++ ACC aaaa SDI=ddd h1rrlssssssaaaasXss36t
[#aaaa|NpidddXJ] dd/dd tt:tt Lxx ACC aaaa RF RCVR TROUBLE h1rrlssssssaaaasTsD17t
[#aaaa|NET] 618. RF Receiver Tamper 619. RF Receiver Tamper Restore 620. RF Receiver Trouble D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Refer to Section C.1 Zonex and Comex Translation on page 137. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 RF BATTERY LOW POINT=ppp D7112 The premises RF receiver was restored from a trouble condition. D7112 The premises RF receiver is in a trouble condition. D7112 113 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 621. RF Receiver Trouble 622. RF Receiver Trouble Since Last Call 623. RF Tamper Trouble (Area Not Reported) 624. RF Transmitter Battery Restore 625. RF Transmitter Battery Restore (for use with Keyfob device) (user < 255) Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: dd/dd tt:tt Lxx ACC aaaa RCVR TROUBLE +++ ACC aaaa SDI=ddd h1rrlssssssaaaasTsD17t
[#aaaa|NpidddET] +++ ACC aaaa RF RCVR TROUBLE h1rrlssssssaaaaSTsssst
[#aaaa|OET] The premises RF receiver is in a trouble condition 5. D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 626. RF Transmitter Battery Restore (for use with Keyfob device) (user > 254) Printer: 627. RF Transmitter Battery Restore (points > 254) Printer: 628. RF Transmitter Low Battery Printer: 629. RF Transmitter Low Battery (points > 254) 630. RF Transmitter Low Battery (for use with Keyfob device) (user < 255) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 631. RF Transmitter Low Battery (for use with Keyfob device) (user > 254) Printer: 632. RF Transmitter Tamper Alarm (points > 254) Printer: 114 D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RF TMPR TROUBLE +++ ACC aaaa POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NTTppp] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsD10t
[#aaaa|NpidddXR] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasRsD10t
[#aaaa|NpidddXR] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasRsD10t
[#aaaa|NidiiiiXR] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaXRpppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsD10t
[#aaaa|NpidddXT] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaXTpppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasTsD10t
[#aaaa|NidiiiXT] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasTsD10t
[#aaaa|NidiiiiXT] dd/dd tt:tt Lxx ACC aaaa RF TAMPER ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaTApppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 633. RF Transmitter Tamper Restoral (Area Not Reported) Printer: dd/dd tt:tt Lxx ACC aaaa RF TMPR RSTORAL +++ ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NTRppp] 634. RF Transmitter Tamper Restoral (points > 254) Printer: 635. RF Transmitter Tamper Trouble (points > 254) Printer: 636. SDI Bus Restore (Ground Fault) Printer: 637. SDI Bus Restore (used by preOMNI panels) 638. SDI Device AC Failure (used by postOMNI panels) 639. SDI Device AC Restore (used by postOMNI panels) 640. SDI Device Battery Trouble (used by postOMNI panels) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 641. SDI Device Missing (used by postOMNI panels) Printer: 642. SDI Device Low Battery (used by postOMNI panels) Printer: 643. SDI Device Missing Restore (used by postOMNI panels) 644. SDI Device Overcurrent (used by postOMNI panels) 645. SDI Device Overcurrent Restore (used by postOMNI panels) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa RF TMPR RSTORAL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaTRpppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaTTpppp] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ACC aaaa GROUND FAULT +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa DEVICE AC FAIL +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddEP] dd/dd tt:tt Lxx ACC aaaa DEV AC RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddEQ] dd/dd tt:tt Lxx ACC aaaa DEVICE BAT TRBL +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddEB] dd/dd tt:tt Lxx ACC aaaa DEVICE MISSING +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddEM] dd/dd tt:tt Lxx ACC aaaa DEV BAT RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddEV] dd/dd tt:tt Lxx ACC aaaa DEV MISSING RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddEN] dd/dd tt:tt Lxx ACC aaaa DEV OVERCURRENT +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddYI] dd/dd tt:tt Lxx ACC aaaa DEV OVERCUR RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddYJ] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 115 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 646. SDI Device Tamper (used by postOMNI panels) 647. SDI Device Tamper Restore (used by postOMNI panels) 648. SDI Device Trouble (used by postOMNI panels) 649. SDI Device Trouble Restore (used by postOMNI panels) 650. SDI Fail Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa DEVICE TAMPER +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddES] dd/dd tt:tt Lxx ACC aaaa DEV TAMPER REST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddEJ] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Explanation dd/dd tt:tt Lxx ACC aaaa DEVICE TROUBLE +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddET] dd/dd tt:tt Lxx ACC aaaa DEV TROUBLE RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTsssDt
[#aaaa|NpidddET] 651. SDI Fail Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTsssDt
[#aaaa|NBTD] 652. SDI Fail (Point reported) Printer: dd/dd tt:tt Lxx ACC aaaa SDI FAILURE +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasTspppt
[#aaaa|NpidddETppp] 653. SDI Fail Since Last Call Printer: D6500 Mode: SIA Mode: Printer: 654. SDI Restoral D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 116 Refer to Section C.1 Zonex and Comex Translation on page 137. SDI FAILURE SDI=ddd TROUBLE ZN D +++ ACC aaaa SDI FAILURE h1rrlssssssaaaaSDsssst
[#aaaa|OET] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] A supervised keypad, printer, or other serial device listed in the second line of the report does not operate. Zonex service required message: indicates a trouble condition on the data lines wiring from the POPEX Module to the POPITs. Trouble on wiring connecting control panel and keypads. Point bus, supervised keypad, printer, or other serial device trouble. 2. A supervised keypad, printer, or other serial device listed in the second line of the report does not operate. 5. The supervised keypad, printer, or other serial device listed in the second line of the report was restored. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 655. SDI Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa RESTORAL h1rrlssssssaaaasRsssDt
[#aaaa|NURD] 656. SDI Restoral Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] D6500 Mode: SIA Mode: 657. SDI Restoral (Point reported) Printer: 658. Sensor Reset Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 659. Sensor Reset (ID not reported) 660. Sensor Reset (ID/relay not reported) 661. Sensor Reset (relay > 254, user < 255) 662. Sensor Reset (relay > 254, user >254) 663. Sensor Reset (relay < 255, user < 255) (OMNI) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: ZN D Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Zonex restoral message: indicates a trouble condition on the wiring from the POPEX Module to the POPITs was cleared. Wiring connecting the control panel and keypads restored. Point bus, supervised keypad, printer, or other serial device was restored. 2. SDI RESTORAL SDI=ddd The supervised keypad, printer, or other serial device listed in the second line of the report was restored. dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasRspppt
[#aaaa|NpidddERppp] The supervised keypad, printer, or other serial device listed in the second line of the report was restored. dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ ACC aaaa AREA=a ID=iii RELAY#=rrr h1rrlssssssaaaasNsD27t
[#aaaa|Nria/idiiiXIrrr] The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown. 1, dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ ACC aaaa AREA=a RELAY#=rrr h1rrlssssssaaaasNsD27t
[#aaaa|NriaXIrrr] The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown. 1, The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown. 1, dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNsD27t
[#aaaa|NriaXI] SENSOR RESET AREA=a 7, 8. 7, 8, D7112 7, 8, D7112 dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=aa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD27t
[#aaaa|Nriaa/idiiiXIrrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=a ID=iiii RELAY#=rrrr h1rrlssssssaaaasNsD27t
[#aaaa|Nria/idiiiiXIrrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=aa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD27t
[#aaaa|Nria/idiiiXIrrr] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 117 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 664. Sensor Reset (relay < 255, user > 254) (OMNI) Printer: dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=a ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD27t
[#aaaa|Nria/idiiiiXIrrr] 665. Sensor Reset Printer: (relay not reported) 666. Sensor Restore (points < 255) 667. Sensor Restore (points > 254) 668. Sensor Trouble (points < 255) 669. Sensor Trouble (points > 254) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 671. Service End D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 672. Service End D6500 Mode: SIA Mode: Printer: 670. Service End 676. Service Start D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 677. Service Start D6500 Mode: SIA Mode: Printer: 673. Service Req’d 674. Service Request 675. Service Start D6500 Mode: SIA Mode: 118 dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD27t
[#aaaa|Nria/idiiiXI] Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The sensor specified in the second line of the report (labeled “RELAY”) located in the specified AREA was reset by a user with the ID shown. 1, 7, 8, D7112 dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRQspppt
[#aaaa|OriaXNppp] dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE +++ACC aaaa AREA=a POINT=pppp h1rrlssssssaaaaRQspppt
[#aaaa|OriaXNppp] dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasQspppt
[#aaaa|OriaXKppp] dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasQppppt
[#aaaa|OriaaXKpppp] dd/dd tt:tt Lxx ACC aaaa SERVICE END h1rrlssssssaaaasRsssFt
[#aaaa|NTE] dd/dd tt:tt Lxx ACC aaaa SERVICE END +++ ACC aaaa AREA=a h1rrlssssssaaaasRsssFt
[#aaaa|NriaTE] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NidiiiTE] SERVICE END ID=iii dd/dd tt:tt Lxx SERVICE REQUIRED RCVR rr h1rrlsssssssssssXsss1t
[NYX] dd/dd tt:tt Lxx ACC aaaa SERVICE REQUEST h1rrlssssssaaaasNsD45t
[#aaaa|NYX] dd/dd tt:tt Lxx ACC aaaa SERVICE START h1rrlssssssaaaasTsssFt
[#aaaa|NTS] dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiTS] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasTsssFt
[#aaaa|NriaTS] SERVICE START AREA=a Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 678. Service Start (no area) 679. Service Start (users > 254) 680. Set Time 681. Shunted 682. Shunted 683. Sked Bypass Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasTsssFt
[#aaaa|NidiiiTS] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 684. Sked Bypass 685. Sked Bypass (point > 254) 686. Sked Changed 687. Sked Changed (users > 254) 688. Skeds Changed Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 689. Sked Changed Printer: D6500 Mode: SIA Mode: 690. Sked Executed Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The POINT in the AREA in the second line of the report is faulted, and was bypassed when the system was armed by the specified Sked. 1, SERVICE START ID=iii dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nriaa/idiiiiTS] dd/dd tt:tt TIME SET RCVR rr h1rrssssssssssssXsss2t
[NJT] dd/dd tt:tt Lxx ACC aaaa SHUNTED ZN z h1rrlssssssaaaasNssszt
[#aaaa|NXWz] dd/dd tt:tt Lxx ACC aaaa SHUNTED ZN zyy h1rrlssssssaaaasNszyyt
[#aaaa|NXWzyy] dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ ACC aaaa AREA=a POINT=ppp SKED=kk h1rrlssssssaaaasNspppt
[#aaaa|Nria/aikkUBppp] dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/aikkkUBpppp] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ACC aaaa SKED=kkk h1rrlssssssaaaasNsD06t
[#aaaa|NaikkkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ACC aaaa ID=iiii SKED=kkk h1rrlssssssaaaasNsD06t
[#aaaa|Nidiiii/aikkkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ ACC aaaa ID= iii SKED=kk h1rrlssssssaaaasNsD06t
[#aaaa|Nidiii/aikkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ ACC aaaa ID=iii SKED=kk h1rrlssssssaaaasNsD06t
[#aaaa|Nidiii/aikkJS] dd/dd tt:tt Lxx ACC aaa EXECUTED h1rrlssssssaaaasNsD25
[#aaaa|NJR] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 D9112 9, D9112 The Sked in the second line of the report was changed by the user with the specified ID. D9112 The Sked in the second line of the report was changed by the user with the specified ID. SKED 119 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: Status report initiated by Skeds or by a user. The POINT in the AREA in the second line of the report is in alarm. 1. D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa S: ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSAspppt
[#aaaa|OriaBAppp] 692. Status: Alarm Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst
[#aaaa|NYY] Indicates that the next report is an account status report. 693. Status: Alarm Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaa ALARM ZN z h1rrlssssssaaaaSAssszt
[#aaaa|OBAz] dd/dd tt:tt Lxx ACC aaaa S:ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt
[#aaaa|OriaaBApppp] dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaASpppp] dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=aa POINT=pppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaaSTppppt
[#aaaa|Oriaa/lvlll/vavvvASpppp] 691. Status: Alarm 694. Status: Alarm (point > 254) 695. Status: Analog Service (points > 254) 696. Status: Analog Service (points > 254) (Level and Value reported) 697. Status: Close by Area D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: 698. Status: Close by Area 699. Status: Close by Area 700. Status: Close by Area SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 701. Status: Door Forced (points > 254) 702. Status: Door Left Open 703. Status: Door Left Open (points > 254) 704. Status: Fire Alarm Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 120 STATUS REPORT dd/dd tt:tt Lxx ACC aaaa S: CLOSING +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaCL] dd/dd tt:tt Lxx ACC aaa STATUS REPORT h1rrlssssssaaaasSsssst
[#aaaa|NYY] dd/dd tt:tt Lxx ACC aaa CLOSING ZN z h1rrlssssssaaaaSCssszt
[#aaaa|OCLz] dd/dd tt:tt Lxx ACC aaaa S:CLOSING +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaCL] 9, D9112 Status report initiated by Skeds or by a user. The AREA in the second line of the report is armed. Indicates that the next report is an account status report. z = area number Status report initiated by Skeds or by a user. The AREA in the second line of the report is armed. dd/dd tt:tt Lxx ACC aaaa S:DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt
[#aaaa|OriaaDFpppp] dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSIspppt
[#aaaa|OriaDNppp] dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSIppppt
[#aaaa|OriaaDNpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 705. Status: Fire Alarm (points < 255) 706. Status: Fire Alarm (points < 255) 707. Status: Fire Alarm (points < 255) 708. Status: Fire Alarm (points < 255) 709. Status: Fire Alarm (points > 254) 710. Status: Fire Alarm (points > 254) 711. Status: Fire Alarm (points > 254) 712. Status: Fire Alarm (points > 254) 713. Status: Fire Alarm (points > 254) 714. Status: Fire Missing 715. Status: Fire Missing (points > 254) 716. Status: Fire Supervision 717. Status: Fire Supervision (points < 255) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSZspppt
[#aaaa|OriaFYppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSZppppt
[#aaaa|OriaaFYpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSEspppt
[#aaaa|OriaFSppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSEppppt
[#aaaa|OriaaFSpppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 121 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 718. Status: Fire Supervision (Water Flow) (point < 255) 719. Status Fire Supervision (Water Flow) (point > 254) 720. Status: Fire Trouble 721. Status: Fire Trouble (points < 255) 722. Status: Fire Trouble (points < 255) 723. Status: Fire Trouble (points < 255) 724. Status: Fire Trouble (points > 254) 725. Status: Fire Trouble (points > 254) 726. Status: Fire Trouble (points > 254) 727. Status: Fire Trouble (points > 254) 728. Status: Missing Alarm 729. Status: Missing Alarm (points > 254) 730. Status: Missing Fire Supervision 122 Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSEspppt
[#aaaa|OriaFSppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSEppppt
[#aaaa|OriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING ALARM +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSZspppt
[#aaaa|OriaUZppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSZppppt
[#aaaa|OriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt
[#aaaa|OriaFZppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 731. Status: Missing Fire Supervision (points < 255) 732. Status: Missing Fire Supervision (points > 254) 733. Status: Missing Fire Supervision (points > 254) 734. Status: Missing Supervision 735. Status: Missing Supervision (points > 254) 736. Status: Missing Trouble 737. Status: Missing Trouble (points > 254) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt
[#aaaa|OriaFZppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt
[#aaaa|OriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt
[#aaaa|OriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS SUPRVISN +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt
[#aaaa|OriaBZppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Explanation dd/dd tt:tt Lxx ACC aaaa S:MISS SUPRVISN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt
[#aaaa|OriaaBZpppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING TRBL +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSVspppt
[#aaaa|OriaUYppp] D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa S:MISSING TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSVppppt
[#aaaa|OriaaUYpppp] dd/dd tt:tt Lxx ACC aaaa S: OPENING +++ ACC aaaa AREA=a h1rrlssssssaaaaSOsssst
[#aaaa|OriaOP] 739. Status: Open by Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst
[#aaaa|NYY] 740. Status: Open by Area Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaaSOssszt
[#aaaa|OOPz] dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst
[#aaaa|NYY] Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaa OPENING ZN z h1rrlssssssaaaaSOssszt
[#aaaa|OOPz] dd/dd tt:tt Lxx ACC aaaa S:PERIM DELAY +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaNL] 738. Status: Open by Area 741. Status:Perimet er Delay by Area 742. Status:Perimet er Delay by Area 743. Status:Perimet er Delay by Area D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Refer to Section C.1 Zonex and Comex Translation on page 137. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 STATUS REPORT OPENING ZN Status report initiated by Skeds or by a user from a keypad: the AREA specified in the second line of the report is disarmed. Indicates that the next report is an Account Status Report. z STATUS REPORT z = area number Indicates that the next report is an Account Status Report. z = area number Status report initiated by Skeds or by a user. The perimeter of the AREA in the second line of the report was delay armed. 123 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation 744. Status:Perimet er Instant by Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa S:PERIM INSTANT +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaNL] Status report initiated by Skeds or by a user. The perimeter of the AREA in the second line of the report is armed. 745. Status:Perimet er Instant by Area Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst
[#aaaa|NYY] Indicates that the next report is an Account Status Report. 746. Status:Perimet er Instant by Area Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa OPENING ZN z h1rrlssssssaaaaSOssszt
[#aaaa|OOPz] dd/dd tt:tt Lxx ACC aaaa S:PERIM INSTANT +++ ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaNL] 748. Status Report Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasSssszt
[#aaaa|NYY] 749. Status: RF Transmitter Low Battery (points > 254) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa S:RF BATTRY LOW +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaXTpppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt
[#aaaa|OriaaTApppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaTApppp] dd/dd tt:tt Lxx ACC aaaa ALARM ZN z h1rrlssssssaaaaSAssszt
[#aaaa|OBAz] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT h1rrlssssssaaaaSCsssst
[#aaaa|OCL] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa CLOSING h1rrlssssssaaaaSCsssit
[#aaaa|OCLi] dd/dd tt:tt Lxx ACC aaaa OPENING h1rrlssssssaaaaSOsssit
[#aaaa|OOPi] 747. Status:Perimet er Instant by Area 750. Status: RF Transmitter Tamper Alarm (points > 254) 751. Status: RF Transmitter Tamper Alarm (points > 254) 752. Status Rpt/Alarm 753. Status Rpt/Closing 754. Status Rpt/Closing 755. Status Rpt/Opening 124 D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: STATUS REPORT STATUS REPORT ID I ID I Refer to Section C.1 Zonex and Comex Translation on page 137. z = area number Status report initiated by Skeds or by a user. The perimeter of the AREA in the second line of the report is armed. Indicates that the next report is an Account Status Report. Unexpanded reporting, system armed by arm/disarm passcode or COMMAND 1 (D8112G2 excluded). Unexpanded reporting, system armed by arm/disarm passcode or CMD 1. AREA armed by user with the ID in the second line of the report. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 756. Status Rpt/Opening Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa OPENING h1rrlssssssaaaaSOsssst
[#aaaa|OOP] 757. Status Rpt/Power Fail Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaaSPsssst
[#aaaa|OAT] 758. Status Rpt/Restoral 759. Status Rpt/Restoral 760. Status Rpt/Trouble 761. Status: Supervision 762. Status: Supervision (points > 254) Explanation REPORT System disarmed. A user with the ID in the second line of the report disarmed the AREA. AC FAILED No AC power. Control panel is running on battery power only. This report is sent along with the next report transmitted. It is not transmitted independently. Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT h1rrlssssssaaaaSRsssst
[#aaaa|OUR] Unexpanded Restoral Report. Command 41. The POINT in the AREA in the second line of the report was restored. Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa RESTORAL ZN z h1rrlssssssaaaaSRssszt
[#aaaa|OURz] dd/dd tt:tt Lxx ACC aaaa TROUBLE ZN z h1rrlssssssaaaaSTssszt
[#aaaa|OBTz] dd/dd tt:tt Lxx ACC aaaa S:SUPERVISION +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaBSppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa S:SUPERVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa S:RF BATT LOW +++ ACC aaaa AREA=a RF POINT =ppp h1rrlssssssaaaaSVspppt
[#aaaa|OriaXTppp] 764. Status: Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasSsssst
[#aaaa|NYY] 765. Status: Trouble Printer: dd/dd tt:tt Lxx ACC aaaa S: TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaBTppp] 763. Status:Transmi tter Low Battery D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 766. Status: Trouble 767. Status: Trouble Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: STATUS REPORT dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaaSTssszt
[#aaaa|OBTz] dd/dd tt:tt Lxx ACC aaaa S:TROUBLE +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaBTppp] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Refer to Section C.1 Zonex and Comex Translation on page 137. Status report. The transmitter at the POINT in the AREA in the second line of the report has a low battery. Indicates that the next report is an Account Status Report. Status report initiated by Skeds or by a user. The POINT in the AREA in the second line of the report is in a trouble condition. 1. 9, D9112 Status report initiated by Skeds or by a user. The POINT in the AREA in the second line of the report is in a trouble condition. 125 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 768. Status: Trouble (point > 254) 769. Supervision (Non-Fire) 770. Supervision (Non-Fire) (points > 254) 771. Supervision (Non-Fire) (points > 254) (Ground Fault) 772. Swinger Bypass Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa S:TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaBTpppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasJspppt
[#aaaa|NriaBSppp] D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 773. Swinger Bypass (Area and ID Not Reported) Printer: 774. Swinger Bypass Printer: D6500 Mode: SIA Mode: Printer: 775. Swinger Bypass (point > 254) 776. Swinger Bypass (7112 Only) 777. Test Failed (Report from UPLINK router indicating “Transceiver Test Failure”) 126 D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|NriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|NriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasNspppt
[#aaaa|NUBppp] SWINGER BYPASS POINT=ppp dd/dd tt:tt Lxx ACC aaa TROUBLE ZN z h1rrlssssssaaaasTssszt
[#aaaa|NBTz] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS h1rrlssssssaaaasNsssst
[#aaaa|NUB] dd/dd tt:tt Lxx ACC aaaa TEST FAILED +++ ACC aaaa PATH=001 COND=001 +++ ACC aaaa UPLINK. h1rrlssssssaaaasTsD49t
[#aaaa|Npt001XX001 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. The POINT in the AREA in the second line of the report (that was programmed for swinger bypass) is faulted, and was bypassed while the system was armed. If the point is restored while the system is armed, it returns to the system and is ready to detect faults. 1. The POINT in the AREA in the second line of the report (that was programmed for swinger bypass) is faulted, and was bypassed while the system was armed. If the point is restored while the system is armed, it returns to the system, and is ready to detect faults. 2, 9. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Event 778. Test-Off Normal Expaned Modem IIIa2 Messages (continued) Device/Mode Display Printer: dd/dd tt:tt Lxx ACC aaaa TEST-OFF NORMAL +++ACC aaaa LOG THRESHOLD +++ACC aaaa LOG OVERFLOW +++ACC aaaa PT BUS TROUBLE +++ACC aaaa PROG ACCESS OK +++ACC aaaa RF RCVR TROUBLE +++ACC aaaa BAD CALL TO RAM +++ACC aaaa USER TAMPER +++ACC aaaa SDI FAILURE +++ACC aaaa COMM FAILURE +++ACC aaaa EQUIPMENT FAIL +++ACC aaaa AC FAILURE +++ACC aaaa BATTERY MISSING +++ACC aaaa BATTERY LOW +++ACC aaaa PARMS BAD CKSUM +++ACC aaaa PHONE FAIL +++ACC aaaa EXTRA RF POINT +++ACC aaaa RF INTERFERENCE +++ACC aaaa FIRE SUPERVISION +++ACC aaaa ANALOG SERVICE +++ACC aaaa FIRE FAULT +++ACC aaaa CTRL POINT FAULT +++ACC aaaa CHK DEVICE FAULT +++ACC aaaa NETWORK FAILURE D6500 Mode: h1rrlssssssaaaasRsssEt h1rrlssssssaaaaSBsssst h1rrlssssssaaaaSLsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSRsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSUsssst h1rrlssssssaaaaSDsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSMsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSEsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSGsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst +++ACC aaaa Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. RF RCVR TAMPER h1rrlssssssaaaaSXss35t Bosch Security Systems, Inc. | 9/07 | 4998122703-02 127 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation Test-Off Normal Expaned SIA Mode:
[#aaaa|NRY]
[#aaaa|OJL]
[#aaaa|OJO]
[#aaaa|OET]
[#aaaa|OLS]
[#aaaa|OET]
[#aaaa|ORA]
[#aaaa|OJA]
[#aaaa|OET]
[#aaaa|OYC]
[#aaaa|OIA]
[#aaaa|OAT]
[#aaaa|OYM]
[#aaaa|OYT]
[#aaaa|OYF]
[#aaaa|OLT]
[#aaaa|OXF]
[#aaaa|OXQ]
[#aaaa|OFS]
[#aaaa|OAS]
[#aaaa|OFT]
[#aaaa|OBT]
[#aaaa|OBT]
[#aaaa|ONT] 779. Test Report NonExpanded Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssEt
[#aaaa|NRP] TEST REPORT 780. Time Changed Printer: TIME CHANGED D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa ID= iii h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiJT] 781. Time Changed Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasNsD07t
[#aaaa|NJT] TIME CHANGED 782. Time Changed (users > 254) Printer: TIME CHANGED ID=iiii D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiiJT] 783. Transmitter Battery Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa RESTORAL h1rrlssssssaaaasRssszt
[#aaaa|NURz] 784. Transmitter Battery Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaXRppp] 785. Transmitter Low Battery Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasTssszt
[#aaaa|NBTz] 786. Transmitter Low Battery Printer: dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaXTppp] Refer to Section C.1 Zonex and Comex Translation on page 137.
[#aaaa|OXS] D6500 Mode: SIA Mode: 128 TROUBLE ZN ZN Test Report D9112 z D7112 The RF POINT transmitter in the AREA in the second line of the report was restored from a low battery. z 1, D7112 D7112 The RF POINT transmitter in the AREA in the second line of the report has a low battery. 1, D7112 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. 787. Transmitter Tamper Alarm Printer: Tamper alarm at the RF POINT in the AREA in the second line of the report. 1, D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa TAMPER ALARM +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaTAppp] 788. Transmitter Tamper Alarm Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt
[#aaaa|NBAz] 789. Transmitter Tamper Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRssszt
[#aaaa|NURZ] 790. Transmitter Tamper Restoral Printer: dd/dd tt:tt Lxx ACC aaaa TAMPER RESTORAL +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaTRppp] The tamper alarm at the RF POINT in the AREA in the second line of the report was restored. 1, 791. Transmitter Tamper Trouble Printer: Tamper trouble at the RF POINT in the AREA in the second line of the report. 1, D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa TAMPER TROUBLE +++ ACC aaaa AREA=a RF POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaTTppp] 792. Transmitter Tamper Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa TROUBLE h1rrlssssssaaaasTssszt
[#aaaa|NBTz] 793. Trouble Printer: Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition. Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition. D6500 Mode: SIA Mode: ALARM ZN RESTORAL ZN ZN z D7112 z D7112 z SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTsssst
[#aaaa|NBT] TROUBLE REPORT 795. Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTssszt
[#aaaa|NBTz] TROUBLE 796. Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa TROUBLE h1rrlssssssaaaasTszyyt
[#aaaa|NBTzyy] ZN zyy 797. Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa TROUBLE h1rrlssssssaaaasTssxxt
[#aaaa|NBTxx ZN xx 798. Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasTss16t
[#aaaa|NBT16] TROUBLE ZN 16 The zone number shown (1 to 8) reports a trouble condition. 799. Trouble Printer: dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaBTppp] Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition. dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasTspppt
[#aaaa|NBTppp] Unexpanded trouble report. The POINT in the AREA in the second line of the report is in a trouble condition. 800. Trouble (Area Not Reported) Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 9/07 | 4998122703-02 D7112 9. 794. Trouble D6500 Mode: SIA Mode: D7112 2, dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaBTppp] D6500 Mode: D7112 ZN 1, 10. z TROUBLE REPORT POINT=ppp 129 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 801. Trouble (with Ground Fault) (point > 254) Printer: dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaBTpppp] 802. Trouble Door Forced (point > 254) Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 803. Trouble (point > 254) Explanation dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaDJpppp] D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaBTpppp] 804. Trouble Fire Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa TROUBLE h1rrlssssssaaaaGsssszt
[#aaaa|NFTz] FR 805. Unknown Message Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx UNKNOWN h1rrlsssssssssssXss25t
[NYO] RCVR rr 806. Unverfied Events (points < 255) Printer: dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaBGppp] 807. Unverfied Events (points < 255) Printer: 808. Unverfied Events (points < 255) Printer: 809. Unverfied Events (points < 255) Printer: 810. Unverfied Events (points < 255) Printer: 811. Unverfied Events (points > 254) Printer: 812. Unverfied Events (points > 254) Printer: 813. Unverfied Events (points > 254) Printer: 814. Unverfied Events (points > 254) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaFGpppp] 815. User Alarm Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa USR ALRM ZN h1rrlssssssaaaasUssszt
[#aaaa|NPAz] 130 Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Refer to Section C.1 Zonex and Comex Translation on page 137. z dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaFGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaBGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaFGppp] dd/dd tt:tt Lxx ACC aaaa UNVERFIED EVENT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaUGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaBGpppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaFGpppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaBGpppp] z Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 816. User Alarm 7 Device/Mode Display Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Printer: dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasUsss7t
[#aaaa|Nria/idiiiUA] A user with the ID in the second line of the report initiated a CMD 7 in the AREA. 1. A user with the ID in the second line of the report initiated a CMD 7 in the AREA. 1, D6500 Mode: SIA Mode: 817. User Alarm 7 (ID not reported) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ ACC aaaa AREA=a h1rrlssssssaaaasUsss7t
[#aaaa|NriaUA] 818. User Alarm 7 Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt
[#aaaa|NBAz] Printer: dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ACC aaaa AREA=a h1rrlssssssaaaasUsss7t
[#aaaa|NriaUA] 819. User Alarm 7 (area only) D6500 Mode: SIA Mode: 820. User Alarm 7 (user > 254) 821. User Alarm 9 822. User Alarm 9 Printer: (ID not reported) 824. User Alarm 9 (area only) D7112: z=7 D9112: z= as programmed for point (Point Code Digit One =4) dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasAssszt
[#aaaa|NBAz] Printer: dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasUsss9t
[#aaaa|Nria/idiiiPA] A user with the ID in the second line of the report initiated a CMD 9 in the specified AREA. 1. dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ ACC aaaa AREA=a h1rrlssssssaaaasUsss9t
[#aaaa|NriaPA] A user with the ID in the second line of the report initiated a CMD 9 in the specified AREA. 1, Printer: D6500 Mode: SIA Mode: Printer: Printer: Printer: D6500 Mode: SIA Mode: 827. User Code Added (users > 254, code > 254) 2, Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 826. User Code Added z D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 825. User Alarm 9 (user > 254) ZN dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasUsss7t
[#aaaa|Nriaa/idiiiiUA] D6500 Mode: SIA Mode: 823. User Alarm 9 ALARM D7112 Printer: D6500 Mode: SIA Mode: ALARM ZN z 2, D7112: z=9 D9112: z= as programmed for point (Point Code Digit One =5) D7112 dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ACC aaaa AREA=a h1rrlssssssaaaasUsss9t
[#aaaa|NriaPA] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasUsss9t
[#aaaa|Nriaa/idiiiiPA] dd/dd tt:tt Lxx ACC aaaa USER CODE ADDED +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD38t
[#aaaa|NidiiiJYccc] dd/dd tt:tt Lxx ACC aaaa USER CODE ADDED +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD38t
[#aaaa|NidiiiiJYcccc] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 131 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event 828. User Code Changed Device/Mode Display Explanation Printer: dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD04t
[#aaaa|NidiiiJVccc] The passcode user ID in the second line of the report was changed by the operator with the specified OPER ID. dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ ACC aaaa AREA=a CODE ID=ccc ID=iii h1rrlssssssaaaasNsD04t
[#aaaa|Nria/idiiiJVccc] The passcode user ID in the second line of the report was changed by the operator with the specified OPER ID. D7112 dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ ACC aaaa AREA=a CODE ID=ccc h1rrlssssssaaaasNsD04t
[#aaaa|NriaJVccc] The passcode user ID in the second line of the report was changed by the operator with the specified OPER ID. D7112 dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD05t
[#aaaa|NidiiiJXccc] The user ID specified in the second line of the report was deleted by the operator with the OPER ID shown. D9112 dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ ACC aaaa AREA= a CODE ID=ccc ID=iii h1rrlssssssaaaasNsD05t
[#aaaa|Nria/idiiiJXccc] The user ID specified in the second line of the report was deleted by the operator with the OPER ID shown. D7112 The user ID specified in the second line of the report was deleted by the operator with the OPER ID shown. D7112 dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPE +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD03t
[#aaaa|Nria/idiiiJA] Five attempts were made in 5 min to access the AREA in the second line of the report with the invalid user ID shown. 1, dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPER +++ ACC aaaa AREA=a h1rrlssssssaaaasNsD03t
[#aaaa|NriaJA] Five attempts were made in 5 min to access the AREA in the second line of the report with the invalid user ID shown. 1, D6500 Mode: SIA Mode: 829. User Code Changed Printer: D6500 Mode: SIA Mode: 830. User Code Changed (operator ID not reported) Printer: D6500 Mode: SIA Mode: 831. User Code Changed (users > 254) Printer: 832. User Code Deleted Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 833. User Code Deleted Printer: D6500 Mode: SIA Mode: 834. User Code Deleted Printer: D6500 Mode: SIA Mode: 835. User Code Deleted (operator ID not reported) Printer: D6500 Mode: SIA Mode: 836. User Code Deleted (User ID# > 254 reported) Printer: 837. User Code Tamper Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 838. User Code Tamper Printer: D6500 Mode: SIA Mode: 132 Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD04t
[#aaaa|NidiiiiJVcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ACC aaaa CODE ID=cccc h1rrlssssssaaaasNsD05t
[#aaaa|NJXcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ ACC aaaa AREA= a CODE ID=ccc h1rrlssssssaaaasNsD05t
[#aaaa|NriaJXccc] dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD05t
[#aaaa|NidiiiiJXcccc] D9112 D7112 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event 839. User Code Tamper (Area and ID Not Reported) 840. User Level Set Device/Mode Display Explanation Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPER h1rrlssssssaaaasNsD03t
[#aaaa|NJA] Five attempts were made in 5 min to access the AREA in the second line of the report with the invalid user ID shown. Printer: dd/dd tt:tt Lxx ACC aaaa USER LEVEL SET +++ ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD40t
[#aaaa|NidiiiJZccc] D6500 Mode: SIA Mode: 841. User Level Set (modified user only) Printer: 842. User Level Set (users > 254) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasNsD40t
[#aaaa|NJZcccc] USER LEVEL SET CODE ID=cccc D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa USER LEVEL SET +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD40t
[#aaaa|NidiiiiJZcccc] 843. User Tamper Since Last Call Printer: D6500 Mode: SIA Mode: +++ ACC aaaa h1rrlssssssaaaaSUsssst
[#aaaa|OJA] 844. [User Text] Printer: D6500 Mode: SIA Mode: +++ ACC aaaa (user text) no message no message 845. Valid Access Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa PROG ACCESS h1rrlssssssaaaasRsF01t
[#aaaa|NLS] 846. Valid Access (via SDI Device or D5360) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa PROG ACCESS OK +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsF01t
[#aaaa|NpidddLS] 847. Valid Local Access Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsF01t
[#aaaa|NpidddLS] 848. Valid Local Access Since Last Call Printer: D6500 Mode: SIA Mode: +++ ACC aaaa h1rrlssssssaaaaSRsssst
[#aaaa|OLS] 849. Valid Remote Access Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|Nph5RS] Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NphhRS] (phone not reported) 850. Valid Remote Access Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Refer to Section C.1 Zonex and Comex Translation on page 137. USER TAMPER A supervised keypad, printer, or other serial device listed in the second line of the report does not operate. 5. The account was locally accessed through the supervised keypad or other serial device specified in the second line of the report. D7112 The account was locally accessed through the supervised keypad or other serial device specified in the second line of the report. 5. RAM ACCESS OK PHONE#=5 The account was contacted by a RAM on the PHONE# specified in the second line of the report. D9112 RAM ACCESS OK The account was contacted by a RAM on the PHONE# specified in the second line of the report. D7112 OK PROG ACCESS OK PROG ACCESS OK 133 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 851. Valid Remote Access Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa h1rrlssssssaaaasRsssFt
[#aaaa|NURF] 852. Valid Remote Access (2112, 9112) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa RAM ACCESS h1rrlssssssaaaasRsssFt
[#aaaa|NRS] 853. Valid Remote Access (from Call Back) Printer: RAM ACCESS OK PH#=hh D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NphhhRS] 854. Valid Remote Access Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NRS] RAM ACCESS OK 855. Variable Text Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx text as received h3rrltext as receivedt
[Atext as rcvd] 856. Walk Test End Printer: dd/dd tt:tt Lxx ACC aaaa +++ ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NriaTE] (no call back) D6500 Mode: SIA Mode: 857. Walk Test End (Invisible Points) (users < 255) Printer: 858. Walk Test End (Invisible Points) (users > 254) Printer: 859. Walk Test End (no user) Printer: 860. Walk Test End (users > 254) Printer: 861. Walk Test Point (points > 254) Printer: 862. Walk Test Point – Fire (points > 254) Printer: 863. Walk Test Start Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: 864. Walk Test Start (Invisible Points) (users < 255) 134 Printer: D6500 Mode: SIA Mode: Explanation RESTORAL ZN F Refer to Section C.1 Zonex and Comex Translation on page 137. 2. OK The account was contacted by a RAM on the PHONE# specified in the second line of the report. D9112 RCVR rr WALK TEST END AREA=a dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasRsssFt
[#aaaa|Nria/idiiiTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt
[#aaaa|Nriaa/idiiiiTE] dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NriaTE] WALK TEST END AREA=a dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt
[#aaaa|Nriaa/idiiiiTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST PT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasZppppt
[#aaaa|NriaaBXpppp] dd/dd tt:tt Lxx ACC aaaa WALK TST PT-FIR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasZppppt
[#aaaa|NriaaFXpppp] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiTS] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiTS] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 865. Walk Test Start (Invisible Points) (users > 254) Printer: dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nriaa/idiiiiTS] 866. Walk Test Start (no user) Printer: 867. Walk Test Start (users > 254) Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa AREA=a ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiiTS] 868. Was Force Armed Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa WAS FORCE ARMED h1rrlssssssaaaasWsssst
[#aaaa|NCW] Account armed with zones or points faulted. The faulted zones or POPITs were not armed. Zones, areas, or points that were not armed are indicated by a TROUBLE or SHUNTED report. 869. Watchdog Reset Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaa RESTORAL h1rrlssssssaaaasRsss9t
[#aaaa|NUR9] Battery restoral report, control panel reboot, watchdog reset, power reset, or ResetBye with RAM. D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa AREA=a h1rrlssssssaaaasTsssFt
[#aaaa|NriaTS] ZN 9 Control panel reboot, watchdog reset, power reset, or ResetBye with RAM (can also be battery restoral report for D7112). 870. Watchdog Reset Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa h1rrlssssssaaaasNsD09t
[#aaaa|NYW] WATCHDOG RESET The control panel’s watchdog reset. This is a non-emergency troubleshooting message. If it is followed by SDI ##, call Bosch Security Systems Technical Support during normal business hours for help in interpreting the message. 871. Watchdog Reset Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET +++ ACC aaaa POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt
[#aaaa|NpidddYWppp] The control panel's watchdog reset. This is a non-emergency troubleshooting message. If it is followed by SDI ##, call Bosch Security Systems Technical Support during normal business hours for help in interpreting the message. Printer: D6500 Mode: SIA Mode: dd/dd tt:tt +5 RESTORED h1rrssssssssssssXsss4t
[NYQ] (SDI Device and Point reported) 872. +5V Restored Bosch Security Systems, Inc. | 9/07 | 4998122703-02 RCVR rr 135 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages Table 92: Modem IIIa2 Messages (continued) Event Device/Mode Display 873. +5V Troubled Printer: D6500 Mode: SIA Mode: dd/dd tt:tt +5 TROUBLED h1rrssssssssssssXsss3t
[NYP] RCVR rr 874. +12V Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt +12 RESTORED h1rrssssssssssssXsss4t
[NYQ] RCVR rr 875. +12V Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt +12 TROUBLED h1rrssssssssssssXsss3t
[NYP] RCVR rr 876. -12V Restoral Printer: D6500 Mode: SIA Mode: dd/dd tt:tt -12 RESTORED h1rrssssssssssssXsss4t
[NYQ] RCVR rr 877. -12V Trouble Printer: D6500 Mode: SIA Mode: dd/dd tt:tt -12 TROUBLED h1rrssssssssssssXsss3t
[NYP] RCVR rr 136 Explanation Refer to Section C.1 Zonex and Comex Translation on page 137. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix C: Modem IIIa2 Messages . C.1 Zonex and Comex Translation These numbered items correspond to the number in the last column in Table 92 starting on page 61. 1. The D7112/D9112 verifies the user identification and point data formats and sends them to the automation system. If the control panel requests a translation, the D6600/D6100 converts point data to Zonex format and user IDs to Comex format. If there is no request for translation, points and IDs are sent to the automation PC and print on the connected printer with no conversion. Table 94 shows the translation of User IDs and Table 93 shows the translation of point data. Table 93: 4. Example 1: Log Threshold Since Last Call
[#aaaa|OriaJL] 5. 6. Point to Zonex Translation 7. Point 001-008 009-024 025-040 041-056 057-072 073-088 089-104 105-120 121-136 137-152 153-168 169-184 185-200 201-216 217-232 233-247 Table 94: ID 0 1-5 0-13 14-21 22-29 30-37 38-45 46-53 54-61 62-69 70-249 2. 3. ZONEX 100-800 101-116 201-216 301-316 401-416 501-516 601-616 701-716 801-816 117-132 217-232 317-332 417-432 517-532 617-632 717-731 User ID to Comex Translation COMEX 0 001-005 601-608 701-708 801-808 B01-B08 C01-C08 D01-D08 E01-E08 F01-F08 000 When the D7112 is transmitting a test report in Modem II format, the area number is sent to the automation system if the output format is in SIA communications mode. 8. 9. When transmitted by a D7112, the identification number, if any, also prints. Refer to Forced Point in the D9112B Program Entry Guide (P/N: 74-06145-000-D). Not entering a phone number turns off these messages for the event class. All messages in this class exist in a unique event class. For these events, the area denotes the location of the keypad used to initiate the event (see Sensor Reset). BFSK Format: For the D9112, unless otherwise specified, the zone digit “z” uses the “BFSK Zone Code” as a base for a given point. This code is programmed in the control panel by point. The zone digit “i” indicates the most significant digit of the user ID. For the D7112, unless otherwise specified, Table 95 is the basis for the zone digit “z” and ID translation; however, actual IDs only go up to 25. Table 95: Reported Zone/ID to Actual Point/ID Reported Zone/ID Actual Point/ID 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 17 25 33 41 10 18 26 34 42 11 19 27 35 43 12 20 28 36 44 13 21 29 37 45 14 22 30 38 46 15 23 31 39 47 16 24 32 40 48 10. This message reports from a D7112 RF point. The internal or external printer prints the label “RF POINT=” instead of “POINT=” in the second line (Example 2). Example 2: Label RF Point dd/dd tt:tt ql ACC aaaa FIRE ALARM +++ ACC aaaa AREA=a RF POINT=ppp A D7112 using the Modem II format can transmit these messages. Not used. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 137 Conettix D6600/D6100i | Computer Interface Manual | Appendix D: Network Messages Appendix D: Network Messages For networked accounts, Nxx appears instead of Lxx in the line number. Table 96: 1 2 3 4 5 6 7 8 9 10 138 Network Messages Event Device/Mode Display Explanation Alarm-Panel Substitution Printer: dd/dd tt:tt Nxx ACC aaaa ALARM-PNL SUBST +++ ACC aaaa PATH=003 COND=007 h1rrlssssssaaaaAsD53t
[#aaaa|Npt003AA007] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 VOLTAGE LOW h1rrlssssssaaaasXss58t
[#aaaa|NSC0002] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 VOLTAGE RESTORE h1rrlssssssaaaasXss68t
[#aaaa|NSC0003] Condition 007 = Substitution/ Replay Change Of Status (C900 Voltage Low) Change Of Status (C900 Voltage Restore) Change Of Status (C900 Input Restored) Change Of Status (C900 Input Shorted) Change Of Status (C900 Intercept Disabled) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Change Of Status (C900 Intercept Enabled) Printer: Change Of Status (C900 Output Activated) Printer: Change Of Status (C900 Output Deactivated) Printer: Change Of Status (C900 Input Open) Printer: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT RESTORED h1rrlssssssaaaasXss91t
[#aaaa|NSC0010] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT SHORTED h1rrlssssssaaaasXss89t
[#aaaa|NSC0008] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INTERCEPT DISABLED h1rrlssssssaaaasXss93t
[#aaaa|NSC0012] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INTERCEPT ENABLED h1rrlssssssaaaasXss92t
[#aaaa|NSC0011] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 OUTPUT ACTIVATED h1rrlssssssaaaasXss85t
[#aaaa|NSC0006] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 OUTPUT DEACTIVATED h1rrlssssssaaaasXss94t
[#aaaa|NSC0007] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT OPEN H1rrlssssssaaaasXss90t
[#aaaa|NSC0009] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix D: Network Messages . Table 96: 11 12 13 14 15 16 17 18 19 20 21 Network Messages (continued) Event Device/Mode Display Change Of Status (C900 Reboot) Printer: dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 REBOOT h1rrlssssssaaaasXss59t
[#aaaa|NSC0001] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 SWITCHED TO FALLBACK h1rrlssssssaaaasXss82t
[#aaaa|NSC0005] Change Of Status (C900 Switched to Fallback) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Change Of Status (C900 Switched To Intercept) Printer: Command Sent (Activate Output) Printer: Command Sent (Deactivate Output) Command Sent (Disable Intercept Mode) Command Sent (Switch To Fallback Mode) Command Sent (Switch To Intercept Mode) Command Sent (Supervision Rate Changed) Communications Fail (Account Disabled By Attack) Communications Fail (Polling Lost) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Explanation dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 SWITCHED TO INTERCPT h1rrlssssssaaaasXss87t
[#aaaa|NSC0004] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa ACTIVATE OUTPUT h1rrlssssssaaaasXss84t
[#aaaa|NCO0005] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa DEACTIVATE OUTPUT h1rrlssssssaaaasXss86t
[#aaaa|NCO0006] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa DISABLE INTERCEPT MODE h1rrlssssssaaaasXss83t
[#aaaa|NCO0004] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SWITCH TO FALLBACK MODE h1rrlssssssaaaasXss81t
[#aaaa|NCO0003] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SWITCH TO INTERCEPT MODE h1rrlssssssaaaasXss88t
[#aaaa|NCO0002] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SUPERVISION RATE CHANGED h1rrlssssssaaaasXss66t
[#aaaa|NCO0001] dd/dd tt:tt Nxx ACC aaaa COMM FAIL +++ ACC aaaa ACCOUNT DISABLED BY ATTACK +++ ACC aaaa PATH=003 COND=008 h1rrlssssssaaaasTsB03t
[#aaaa|Npt003YC008] dd/dd tt:tt Nxx ACC aaaa COMM FAIL +++ ACC aaaa PATH=003 COND=009 h1rrlssssssaaaasTsB02t
[#aaaa|Npt003YC009] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Condition 008 = Attack Condition 009 = Polling Monitor 139 Conettix D6600/D6100i | Computer Interface Manual | Appendix D: Network Messages Table 96: 22 23 24 25 26 27 28 29 30 140 Network Messages (continued) Event Device/Mode Display Explanation Communications Fail Restore (Poll Restore) Printer: Condition 009 = Polling Monitor Dialer Error (Dialing Error) Printer: dd/dd tt:tt Nxx ACC aaaa COMM FAIL RESTR +++ ACC aaaa PATH=003 COND=009 h1rrlssssssaaaasNsB02t
[#aaaa|Npt003YK009] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa DIALING ERROR h1rrlssssssaaaasXss73t
[#aaaa|NYU0003] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa INVALID MESSAGE h1rrlssssssaaaasXss77t
[#aaaa|NYU0007] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa MESSAGE UNKNOWN h1rrlssssssaaaasXss76t
[#aaaa|NYU0006] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO ACKNOWLEDGMNT RECEIVED h1rrlssssssaaaasXss71t
[#aaaa|NYU0001] Dialer Error (Invalid Message) Dialer Error (Message Unknown) Dialer Error (No Acknowledgement Received) Dialer Error (Not Dialing) Dialer Error (No Response to Acknowledgement) Dialer Error (No Response to Handshake) Miscellaneous Message (30 Minutes Since Fallback Command) D6500 Mode: SIA Mode: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NOT DIALING h1rrlssssssaaaasXss72t
[#aaaa|NYU0002] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO RESPONSE TO ACK h1rrlssssssaaaasXss75t
[#aaaa|NYU0005] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO RESPONSE TO HANDSHAKE h1rrlssssssaaaasXss74t
[#aaaa|NYU0004] dd/dd tt:tt Nxx ACC aaaa MESSAGE +++ aaaa 30 MIN SINCE FALLBACK CMD h1rrlssssssaaaasXss95t
[#aaaa|NMI0001] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Appendix E: Pulse Output Table 97 to Table 105 (on page 145) vary depending on the account number specified and the digit parameter programmed using the drop-down menus in Menu Item 3.1.7 Event 3/1 or 4/1 (Figure 26). Figure 26: D6200 Receiver Software Line Card Configuration The output of the receiver depends on the reporting digit. Use the settings in Figure 26 that can be changed by the user: • Reporting digits 0 to 9 and A are alarms • Reporting digit B is an opening • Reporting digit C is a closing • Reporting digit D is a cancel • Reporting digit E is a restore Table 97: # Event 1. Pulse 3/1 Format ALARM Account Number 123 Reporting Digit 4 2. OPENING 123 B 3. CLOSING 123 C 4. CANCEL 123 D 5. RESTORE 123 E 6. TROUBLE 123 F Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 4 [10]1011sssssss123sAsss4[13] [10]602415[9]00030101[#s123|NBA4][13] DD/DD TT:TT L01 ACCT 123 OPENING [10]1011sssssss123sOssss[13] [10]AA4214[9]00040101[#s123|NOP][13] DD/DD TT:TT L01 ACCT 123 CLOSING [10]1011sssssss123sCssss[13] [10]F94B14[9]00050101[#s123|NCL][13] DD/DD TT:TT L01 ACCT 123 CANCEL [10]1011sssssss123s\ssss[13] [10]FBCE14[9]00060101[#s123|NOC][13] DD/DD TT:TT L01 ACCT 123 RESTORE [10]1011sssssss123sRssss[13] [10]FC2214[9]00070101[#s123|NUR][13] DD/DD TT:TT L01 ACCT 123 TROUBLE [10]1011sssssss123sTssss[13] [10]ACD414[9]00080101[#s123|NBT][13] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 141 Conettix D6600/D6100i | Computer Interface Manual | Appendix E: Pulse Output Table 98: # Event 7. Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 1 ALARM Account Number 123 Reporting Digit 45 8. OPENING 123 B5 9. CLOSING 123 C5 10. CANCEL 123 D5 11. RESTORE 123 E5 12. TROUBLE 123 F5 Table 99: # Event 13. Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]720816[9]00090101[#s123|NBA45][13] DD/DD TT:TT L01 ACCT 123 OPENING ZN 5 [10]1011sssssss123sOsss5[13] [10]B0B115[9]00100101[#s123|NOP5][13] DD/DD TT:TT L01 ACCT 123 CLOSING ZN 5 [10]1011sssssss123sCsss5[13] [10]B62215[9]00110101[#s123|NCL5][13] DD/DD TT:TT L01 ACCT 123 CANCEL ZN 5 [10]1011sssssss123s\sss5[13] [10]15E115[9]00120101[#s123|NOC5][13] DD/DD TT:TT L01 ACCT 123 RESTORE ZN 5 [10]1011sssssss123sRsss5[13] [10]98E715[9]00130101[#s123|NUR5][13] DD/DD TT:TT L01 ACCT 123 TROUBLE ZN 5 [10]1011sssssss123sTsss5[13] [10]1CB015[9]00140101[#s123|NBT5][13] Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 2 ALARM Account Number 123 Reporting Digit 45 14. OPENING 123 B5 15. CLOSING 123 C5 16. CANCEL 123 D5 17. RESTORE 123 E5 18. TROUBLE 123 F5 142 Device/Mode Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]210D16[9]00450102[#s123|NBA45][13] DD/DD TT:TT L01 ACCT 123 OPENING ZN B5 [10]1011sssssss123sOssB5[13] [10]829516[9]00460102[#s123|NOPB5][13] DD/DD TT:TT L01 ACCT 123 CLOSING ZN C5 [10]1011sssssss123sCssC5[13] [10]2F8216[9]00470102[#s123|NCLC5][13] DD/DD TT:TT L01 ACCT 123 CANCEL ZN D5 [10]1011sssssss123s\ssD5[13] [10]EC1316[9]00480102[#s123|NOCD5][13] DD/DD TT:TT L01 ACCT 123 RESTORE ZN E5 [10]1011sssssss123sRssE5[13] [10]2E4F16[9]00490102[#s123|NURE5][13] DD/DD TT:TT L01 ACCT 123 TROUBLE ZN F5 [10]1011sssssss123sTssF5[13] [10]C72516[9]00500102[#s123|NBTF5][13] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Table 100: Pulse 3/2 # Event ALARM Account Number 123 Reporting Digit 45 19. 20. OPENING 123 B5 21. CLOSING 123 C5 22. CANCEL 123 D5 23. RESTORE 123 E5 24. TROUBLE 123 F5 Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]446B16[9]00150101[#s123|NBA45][13] DD/DD TT:TT L01 ACCT 123 OPENING B5 [10]1011sssssss123sOssB5[13] [10]17F616[9]00160101[#s123|NOPB5][13] DD/DD TT:TT L01 ACCT 123 CLOSING B5 [10]1011sssssss123sCssC5[13] [10]BAE116[9]00170101[#s123|NCLC5][13] DD/DD TT:TT L01 ACCT 123 CANCEL B5 [10]1011sssssss123s\ssD5[13] [10]797016[9]00180101[#s123|NOCD5][13] DD/DD TT:TT L01 ACCT 123 RESTORE B5 [10]1011sssssss123sRssE5[13] [10]BB2C16[9]00190101[#s123|NURE5][13] DD/DD TT:TT L01 ACCT 123 TROUBLE B5 [10]1011sssssss123sTssF5[13] [10]EA3F16[9]00200101[#s123|NBTF5][13] Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 5 [10]1011ssssss1234sAsss5[13] [10]97CE15[9]00210101[#1234|NBA5][13] DD/DD TT:TT L01 ACCT 1234 OPENING [10]1011ssssss1234sOssss[13] [10]020A14[9]00220101[#1234|NOP][13] DD/DD TT:TT L01 ACCT 1234 CLOSING [10]1011ssssss1234sCssss[13] [10]510314[9]00230101[#1234|NCL][13] DD/DD TT:TT L01 ACCT 1234 CANCEL [10]1011ssssss1234s\ssss[13] [10]908414[9]00240101[#1234|NOC][13] DD/DD TT:TT L01 ACCT 1234 RESTORE [10]1011ssssss1234sRssss[13] [10]976814[9]00250101[#1234|NUR][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE [10]1011ssssss1234sTssss[13] [10]C29B14[9]00260101[#1234|NBT][13] Table 101: Pulse 4/1 # Event ALARM Account Number 1234 Reporting Digit 5 25. 26. OPENING 1234 B 27. CLOSING 1234 C 28. CANCEL 1234 D 29. RESTORE 1234 E 30. TROUBLE 1234 F Bosch Security Systems, Inc. | 9/07 | 4998122703-02 143 Conettix D6600/D6100i | Computer Interface Manual | Appendix E: Pulse Output Table 102: Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1 # Event ALARM Account Number 1234 Reporting Digit 45 31. 32. OPENING 1234 B5 33. CLOSING 1234 C5 34. CANCEL 1234 D5 35. RESTORE 1234 E5 36. TROUBLE 1234 F5 Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]418416[9]00270101[#1234|NBA45][13] DD/DD TT:TT L01 ACCT 1234 OPENING ZN 5 [10]1011ssssss1234sOsss5[13] [10]C5C215[9]00280101[#1234|NOP5][13] DD/DD TT:TT L01 ACCT 1234 CLOSING ZN 5 [10]1011ssssss1234sCsss5[13] [10]C35115[9]00290101[#1234|NCL5][13] DD/DD TT:TT L01 ACCT 1234 CANCEL ZN 5 [10]1011ssssss1234s\sss5[13] [10]3EE515[9]00300101[#1234|NOC5][13] DD/DD TT:TT L01 ACCT 1234 RESTORE ZN 5 [10]1011ssssss1234sRsss5[13] [10]B3E315[9]00310101[#1234|NUR5][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE ZN 5 [10]1011ssssss1234sTsss5[13] [10]F6F615[9]00320101[#1234|NBT5][13] Table 103: Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2 # Event ALARM Account Number 1234 Reporting Digit 45 37. 38. OPENING 1234 B5 39. CLOSING 1234 C5 40. CANCEL 1234 D5 41. RESTORE 1234 E5 42. TROUBLE 1234 F5 144 Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]599816[9]00510102[#1234|NBA45][13] DD/DD TT:TT L01 ACCT 1234 OPENING ZN B5 [10]1011ssssss1234sOssB5[13] [10]FA0016[9]00520102[#1234|NOPB5][13] DD/DD TT:TT L01 ACCT 1234 CLOSING ZN C5 [10]1011ssssss1234sCssC5[13] [10]571716[9]00530102[#1234|NCLC5][13] DD/DD TT:TT L01 ACCT 1234 CANCEL ZN D5 [10]1011ssssss1234s\ssD5[13] [10]F60416[9]00540102[#1234|NOCD5][13] DD/DD TT:TT L01 ACCT 1234 RESTORE ZN E5 [10]1011ssssss1234sRssE5[13] [10]345816[9]00550102[#1234|NURE5][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE ZN F5 [10]1011ssssss1234sTssF5[13] [10]FB2C16[9]00560102[#1234|NBTF5][13] Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Table 104: Pulse 4/2 # Event ALARM Account Number 1234 Reporting Digit 45 43. 44. OPENING 1234 B5 45. CLOSING 1234 C5 46. CANCEL 1234 D5 47. RESTORE 1234 E5 48. TROUBLE 1234 F5 Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]220516[9]00330101[#1234|NBA45][13] DD/DD TT:TT L01 ACCT 1234 OPENING B5 [10]1011ssssss1234sOssB5[13] [10]708D16[9]00340101[#1234|NOPB5][13] DD/DD TT:TT L01 ACCT 1234 CLOSING C5 [10]1011ssssss1234sCssC5[13] [10]DD9A16[9]00350101[#1234|NCLC5][13] DD/DD TT:TT L01 ACCT 1234 CANCEL D5 [10]1011ssssss1234s\ssD5[13] [10]4DC816[9]00360101[#1234|NOCD5][13] DD/DD TT:TT L01 ACCT 1234 RESTORE E5 [10]1011ssssss1234sRssE5[13] [10]8F9416[9]00370101[#1234|NURE5][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE F5 [10]1011ssssss1234sTssF5[13] [10]132316[9]00380101[#1234|NBTF5][13] Device/Mode Displays Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 456 [10]1011ssssss1234sAs456[13] [10]D5C017[9]00390101[#1234|NBA456][13] DD/DD TT:TT L01 ACCT 1234 OPENING B45 [10]1011ssssss1234sOsB45[13] [10]114C17[9]00400101[#1234|NOPB45][13] DD/DD TT:TT L01 ACCT 1234 CLOSING C45 [10]1011ssssss1234sCsC45[13] [10]1FA117[9]00410101[#1234|NCLC45][13] DD/DD TT:TT L01 ACCT 1234 CANCEL D45 [10]1011ssssss1234s\sD45[13] [10]E2B017[9]00420101[#1234|NOCD45][13] DD/DD TT:TT L01 ACCT 1234 RESTORE E45 [10]1011ssssss1234sRsE45[13] [10]DB7217[9]00430101[#1234|NURE45][13] DD/DD TT:TT L01 ACCT 1234 TROUBLE F45 [10]1011ssssss1234sTsF45[13] [10]CC4C17[9]00440101[#1234|NBTF45][13] Table 105: Pulse 4/3 # Event ALARM Account Number 1234 Reporting Digit 456 49. 50. OPENING 1234 B45 51. CLOSING 1234 C45 52. CANCEL 1234 D45 53. RESTORE 1234 E45 54. TROUBLE 1234 F45 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 145 Conettix D6600/D6100i | Computer Interface Manual | Appendix F: Format ID (by Message Type) – D6600 Only Appendix F: Format ID (by Message Type) – D6600 Only If D6600 Menu Item 2.5.17 equals 1, the following outputs apply. Generic Example D6500 Byte Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h 9 r r l s s s s a a a a C C C C C C C C t Table 106: Generic Byte Description # 1 Title Header Character (h) Description Optional, check with the computer automation software for compatibility 2 Message Type 9 3-4 5 6-9 10-13 14-21 22 Receiver Number Line/Group Number Spaces Account Number Channels Trailer Character Receiver gateway number from 01 to 99 Line number in the receiver gateway that sent the message Six spaces Account number, four digits Channels 1 to 8 Typically, this is HEX 14 Generic Example SIA Mode Description <9>[#aaaa|CCCCCCCC] Table 107: Generic SIA Byte Description Title L CRC Description Standard line feed character Cyclical redundancy check number Message Type 9 sequence# The message sequence number, the valid sequence number range is 0001 to 9999 The receiver gateway that sent the message, valid digits are 01 to 99 The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. The communicator's account number, four digits. Channel 1 to 8 receiver# line# (Line/Group #) account# CCCCCCCC The heavier outlined row in Table 106 and Table 107 indicate the meaning of the shaded digit in the D6500 Byte Description, SIA Mode Description Generic Examples, and Table 108 on page 147. Table 108 show examples for each format that the receiver supports. If Menu Item 2.5.17 = 1, the following message type follows a specific format ID. If Menu Item 2.5.17 = 0, the output to automation follows the standard message type ID. 146 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix F: Format ID (by Message Type) – D6600 Only . Table 108: Message Examples # Communication Format Mode Message 1. Acron Super Fast 2. Ademco Contact-ID 3. Ademco 4-1 Express 4. Ademco 4-2 Express 5. Ademco High Speed/ Scancom SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: [10]146D18900120101[#123|45678912][13] [10]9011sssss12345678912[14] [10]6A721Ca00140101[#7401|18113003003][13] [10]a011s740118113003003[14] [10]1FDC12b00150101[#1234|7][13] [10]b011ssssss1234sAsss7[14] [10]9D2F13c00160101[#1234|55][13] [10]c011ssssss1234sAss55[14] [10]C3651Cf00180101[#1234|5678s9123s4][13] [10]f011ss1234s5678s9123s4[14] 5-8-1 SIA: D6500: [10]69311Df00190101[#12345|6789s1234s5][13] [10]f011s12345s6789s1234s5[14] 6-8-1 SIA: D6500: [10]42CD1Ef00200101[#123456|7891s2345s6][13] [10]f011123456s7891s2345s6[14] SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D500: SIA: D6500: SIA: D6500: SIA: D6500: [10]0BB619G00480101[#0308|Nid39OP2][13] [10]G011[#0308|Nid39OP2][14] [10]257B1Ce00570101[#0000|&9569688558][13] [10]e011ssssss9569688558[14] [10]BDAE17i00270101[#123ABC|0108][13] [10]i011ssss123ABC0108ss[14] [10]99EA17d00170101[#1234|NBA567][13] [10]d011ssssss1234sAs567[14] [10]02A215t00400101[#1234|NBA5][13] [10]t011ssssss1234sAsss5[14] [10]40EC16u00410101[#1234|NBA56][13] [10]u011ssssss1234sAss56[14] [10]921C15F00470101[#1234|5678][13] [10]F011ssssss12345678ss[14] [10]5FB90EZ00090124[NLT][13] [10]Z010sssssssssssXss51[14] [10]ABFB19I00490101[#MMTST|g090A31][13] [10]I011sssMvMTSTg090A31[14] [10]2D270B[9]00920100[][13] [10]1010sssssssssss@ssss[14] [10]827316p00340101[#s123|NBA12][13] [10]p011sssssss123sAss12[14] SIA: D6500: SIA: D6500: SIA: D6500: [10]16A815p00330101[#s706|NBA1][13] [10]p011sssssss706sAsss1[14] [10]C37A16q00350101[#s706|NBA61][13] [10]q011sssssss706sAss61[14] [10]608F15r00360101[#7066|NBA0][13] [10]r011ssssss7066sAsss0[14] SIA: D6500: SIA: D6500: [10]5ACC16r00370101[#1234|NBA12][13] [10]r011ssssss1234sAss12[14] [10]8A7F16s00380101[#7066|NBA02][13] [10]s011ssssss7066sAss02[14] SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: [10]185317s00390101[#1234|NBA566][13] [10]s011ssssss1234sAs566[14] [10]8B9C1AA00440101[#1234|Nti1158LF][13] [10]A011ssssss1234s*ssss[14] [10]942B15B00450101[#1481|NUR2][13] [10]B011ssssss1481sRsss2[14] [10]FFF115C00460101[#s2B2|NBA3][13] [10]C011sssssss2B2sAsss3[14] 4-8-1 6. ADT SIA 7. Caller ID 8. CFSK 9. DSC/Sur-Gard 4-3 10. DTMF 4-1 11. DTMF 4-2 12. FBI Super Fast 13. Internal Message 14. ITI 15. Link Test 16. Pulse 3-1 3-1E 17. Pulse 3-2 18. Pulse 4-1 4-1E 19. Pulse 4-2 4-2E 2 20. Modem IIIa or Modem IId 21. Modem II 22. BFSK Bosch Security Systems, Inc. | 9/07 | 4998122703-02 147 Conettix D6600/D6100i | Computer Interface Manual | Appendix F: Format ID (by Message Type) – D6600 Only Table 108: Message Examples (continued) # Communication Format Mode Message 23. Robofon 24. Scancom SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: SIA: D6500: [10]2D3B15j00280101[#123ABC|12][13] [10]j011ssss123ABC12ssss[14] [10]D47C26g00210101[#1234|2222s2222s2222s2222s2][13] [10]g011ss1234s2222s2222s2222s2222s2[14] [10]91FC27g00220101[#12345|2222s2222s2222s2222s2][13] [10]g011s12345s2222s2222s2222s2222s2[14] [10]13EA28g00230101[#123456|2222s2222s2222s2222s2][13] [10]g011123456s2222s2222s2222s2222s2[14] [10]091930h00240101[#1234|2222s2222s2222s2222s2222s2222s2][13] [10]h011ss1234s2222s2222s2222s2222s2222s2222s2[14] [10]D4ED31h00250101[#12345|2222s2222s2222s2222s2222s2222s2][13] [10]h011s12345s2222s2222s2222s2222s2222s2222s2[14] [10]B51132h00260101[#123452|2222s2222s2222s2222s2222s2222s2][13] [10]h011123452s2222s2222s2222s2222s2222s2222s2[14] [10]61F619K00900101[#7080|*#000***][13] [10]K01113*7080*#000***[14] [10]352815k00290101[#123AB|101][13] [10]k011ssssss123ABs1s01[14] [10]787215700110101[#0258|A56s][13] [10]7011ssssss0258sA56ss[14] [10]86E416[9]00500101[#7080|NBA01][13] [10]S011[#7080|NBA01][14] [10]3E6714E01040101[#4444|NOP][13] [10]E011ssssss4444sOssss[13] [10]3E6714E01040101[#4444|NBA13][13] [10]E011ssssss4444sAss08[14] [10]DC7115m00300101[#7654|sA01][13] [10]m011s7654"sA01[14] SIA: D6500: [10]8AAC17m00310101[#123456|HA00][13] [10]m011s123456"HA00[14] SIA: D6500: SIA: D6500: [10]C2EB26n00320101[#000257|1090000000110000000][13] [10]n011s000257s1s090000000110000000[14] [10]8EFA16v00430101[#1234|NBA98][13] [10]v011ssssss1234sAss98[14] SIA: D6500: SIA: D6500: SIA: D6500: [10]802515v00420101[#1234|NBA9][13] [10]v011ssssss1234sAsss9[14] [10]802515V00450101[#55|123456789ABCDEFG][13] [10]V01155123456789ABCDEFG [14] [10]86E416[9]01430101[#1234|6011100*’THISISATEST’12][13] [10]S011[#1234|6011100*’THISISATEST’12][14] 4-16-1 5-16-1 6-16-1 25. Scancom 4-24-1 5-24-1 6-24-1 26. Seriee DTMF 27. Seriee FSK 28. Sescoa Super Speed 29. SIA 30. Silent Knight FSK 0 FSK80 31. Silent Knight FSK1 FSK2 32. Telim 33. Varitech FSK 4-1,Varitech FSK 4-2 34. VONK 35. X-SIA 148 VFSK 4-2 VFSK 4-1 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix G: ADT SIA Report Codes . Appendix G: ADT SIA Report Codes Table 109: ADT SIA Report Codes Description ADT SIA System Event System Reset Reset Memory AC Fail AA AC Restore AH AC Fail 4 hour AT AC Fail 4 hour Restore AJ LT TELCO Line Trouble (Line 1 or Line 2) LR TELCO Line Trouble Restore (Line 1 or Line 2) Low Battery System YT Low Battery Restore YR Change Date Description ADT SIA Expansion Module IA Interactive Keypad Tamper IT Interactive Keypad Trouble – Supervision IR Interactive Keypad Restore Cardreader Alarm DA Cardreader Trouble DT Cardreader Restore DR EA Point Gateway Tamper Alarm ET Point Gateway Tamper – Supervision Point Gateway Restore ER Printer Tamper Alarm PA PT Printer Trouble – Supervision Printer Restore PR Description ADT SIA Downloading DLL Aborted RA Start DLL RB DLL Interrupted RI End DLL Altered RS DLL Comm Fail RT End DLL Not Altered RG Description ADT SIA Burglary BA Burg Alarm BA PT Bypass BA Restore BA Trouble BA PT Unbypass Description ADT SIA Panic BA BB BR BT BU Description Open/Close BA Auto Close BA Auto Close with Bypass – within Group BA Trouble Closing (closed with burg during exit) BA Bypass Closing – within Group BA Closing BA Auto Open BA Irregular Opening BA Opening BA No Close – Sched close time expire BA Exit Fail, exit error (user) ADT SIA Description ADT SIA CA CB CF Hold-Up Alarm Hold-Up Point Trouble (sensor trouble) Hold-Up Restore Hold-Up Point Bypass Hold-Up Point Unbypass Hostage Alarm (Duress) Hostage Restore Medical Alarm Medical Restore Description CG CL OA OI OP OT HA HT HR HB HU HH HR MA MR ADT SIA Scheduling BA Change Close Time Change Auto On Level Change Close Time Print Only EF Fire Fire Alarm Fire Trouble Fire Restore Fire Alarm Silence Fire Point Bypass Fire Alarm Point Unbypass Supervisory Alarm Supervisory Trouble Supervisory Restore Supervisory Point Bypass Supervisory Unbypass Bosch Security Systems, Inc. | 9/07 | 4998122703-02 FA FT FR FB FU SS ST SR SB SU 149 Conettix D6600/D6100i | Computer Interface Manual | Appendix G: ADT SIA Report Codes Table 109: ADT SIA Report Codes (Continued) Description Other Supervised Bell Alarm Supervised Bell Trouble Supervised Bell Restore Remote Power Supply Alarm Remote Power Supply Trouble Remote Power Supply Restore Keyswitch Alarm Keyswitch Trouble Keyswitch Restore Janitor Keyswitch Alarm Janitor Keyswitch Trouble Janitor Keyswitch Restore Janitor On Premises (user on premises) Janitor Off Premises (user on premises restore) ADT On Premises ADT Off Premises Tamper Alarm Tamper Restore VVS Bypass VVS Unbypass Keypad Active Audible Walk Test Change Code Change Early Open Change Holiday Change Latest Close (sent to CMC only if Closing sched is altered) Change Open Time, schedule change Change Time, time/date reset 150 ADT SIA UA UT UR UA UT UR UA UT UR UA UT UR JI JO SI SO TA TR VB VU AC AT CL Description System Test Walk Test, walk test mode Bell Test Hold-Up Test Alarm (sent to printer) Hold-Up Test Restore (sent to printer) Start FA Test, fire test End FA Test, fire test restore Start BA Test End BA Test Start Supervision Test End Supervision Test Start Hold-Up Test End Hold-Up Test Long Print Short Print Supervisory Test Print, manual trigger test report Supervisory Test Restore Fire Test Alarm Print, fire test Fire Test Restore Print, fire test restore BA Point Test Print BA Point Test Restore Print Hold-Up Suspicion Print Keypad No Access Untyped Bypass Untyped Unbypass Tamper Bypass Tamper Unbypass BA Diagnostics FA Diagnostics Output Trouble Output Restore Point Trouble Point Alarm, general alarm ADT SIA ADT SIA UR BT Description Point Restore, general alarm restore Untyped Diagnostics BA Weak Battery FA Weak Battery HA Weak Battery SA Weak Battery UA Weak Battery FM FK Description ADT SIA WT BN BK SM SK HM HK ST ST FA FR Access 2 Man 2nd Person Keypad Lockout Cardreader Irregular Access Manual PB Access, remote arm/disarm opening Access Denied Code Known, access denied Access Denied Code Unknown, access denied UW BL FL HL SL UL DI MP DK DD Description ADT SIA Dialer Test Report Dialer Test Report RP1 RP5 Dialer Test Report with System Trouble BT BT HS NA UB UU TB TU BW FW UT UR UT UA Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix H: RB2000 Messages (D6600 Only) . Appendix H: RB2000 Messages (D6600 Only) For lines that are grouped, Gxx appears instead of Lxx. Table 110: RB2000 Messages # Event 1. Mains Power Failure 2. 3. Device/ Mode SIA Printer SIA Printer Mains Power Return 4. SIA Printer SIA Printer 5. Battery Broken SIA Printer 6. RF Y Battery Empty SIA Printer 7. RF Y Battery Full SIA Printer 8. HTS Battery Empty SIA Printer 9. HTS Battery Full SIA Printer 10. Sensor Battery SIA Printer 11. SIA Printer 12. Technical Alarm SIA Printer 13. Technical Alarm Confirmed SIA Printer Display
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 32
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 34
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B2
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B4
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 33
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 33
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B7
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 37
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B7
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 38
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B8
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 41
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C1 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 151 Conettix D6600/D6100i | Computer Interface Manual | Appendix H: RB2000 Messages (D6600 Only) Table 110: RB2000 Messages (continued) # Event 14. PRO 100 Transmitter 15. 16. SIA Printer PRO 100 Pull Cord 17. 18. PRO 100 Situation Alarm Pull Switch Confirmation at Local Unit Hand Transmitter/Button 29. 152 SIA Printer SIA Printer Emergency Button 27. 28. SIA Printer SIA Printer 25. 26. SIA Printer SIA Printer 23. 24. SIA Printer SIA Printer 21. 22. SIA Printer SIA Printer 19. 20. Device/ Mode SIA Printer SIA Printer SIA Printer External Input X SIA Printer SIA Printer Display
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 42
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C2
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 43
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C3
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 44
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C4
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 46
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C6
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 47
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C7
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 48
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C8
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 49
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C9
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 49
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX C9 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix H: RB2000 Messages (D6600 Only) . Table 110: RB2000 Messages (continued) # Event 30. RF Y - Alarm 31. 32. SIA Printer Activity Monitor 33. 34. Device/ Mode SIA Printer SIA Printer SIA Printer Fire Alarm 35. SIA Printer SIA Printer 36. Fire Alarm from Ext Input X SIA Printer 37. Intrusion SIA Printer 38. SIA Printer 39. Intrusion from Ext Input X SIA Printer 40. Intrusion from RF X SIA Printer 41. External Alarm Button SIA Printer 42. 43. SIA Printer Protocol Error 44. 45. 46. SIA Printer SIA Printer RF Y Error SIA Printer SIA Printer Display
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 49
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY C9
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4A
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CA
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4B
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CB
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4B
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4C
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CC
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4C
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4C
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4D
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CD
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4E
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CE
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 51
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D1 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 153 Conettix D6600/D6100i | Computer Interface Manual | Appendix H: RB2000 Messages (D6600 Only) Table 110: RB2000 Messages (continued) # Event 47. RF Y Maintenance 48. 49. SIA Printer RF Y Start 50. 51. RF Y Disassembly RF Y Test OK RF Y Test NOK SIA Printer SIA Printer RF Y Plug 58. 59. SIA Printer SIA Printer 56. 57. SIA Printer SIA Printer 54. 55. SIA Printer SIA Printer 52. 53. Device/ Mode SIA Printer SIA Printer SIA Printer RF Y Test 60. SIA Printer SIA Printer 61. Outgoing Call HNZ SIA Printer 62. Resetting SIA Printer 63. Personal Sign In SIA Printer 154 Display
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 52
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D2
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 53
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D3
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 54
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D4
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 55
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D5
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 56
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D6
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 57
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D7
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 58
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D8
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 60
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 61
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx+++ 0E 00 00 00 62 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix H: RB2000 Messages (D6600 Only) . Table 110: RB2000 Messages (continued) # Event 64. Personal Sign Out 65. Door Alarm SIA Printer 66. Bed Alarm SIA Printer 67. Medical Remind SIA Printer 68. Message 1 SIA Printer 69. Message 2 SIA Printer 70. Message 3 SIA Printer 71. Sign Out SIA Printer 72. 73. SIA Printer Sign In 74. 75. Device/ Mode SIA Printer SIA Printer SIA Printer Service Call 76. SIA Printer SIA Printer 77. Repeated Call SIA Printer 78. Confirmation Call SIA Printer 79. Pager Call Activated SIA Printer 80. Full Duplex Communication SIA Printer Display
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 63
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 64
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 65
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 66
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 67
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 68
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 69
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 71
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 78
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F1
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F8
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 72
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F2
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 73
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F3
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 74
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 75 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 155 Conettix D6600/D6100i | Computer Interface Manual | Appendix H: RB2000 Messages (D6600 Only) Table 110: RB2000 Messages (continued) # Event 81. Test Call 82. 83. SIA Printer RF Jamming 84. 85. RF Y No Alive Call for Assistance SIA Printer SIA Printer Registration Call 90. 91. SIA Printer SIA Printer 88. 89. SIA Printer SIA Printer 86. 87. Device/ Mode SIA Printer SIA Printer SIA Printer Manual Test Call 92. SIA Printer SIA Printer 93. Release Code XX XX SIA Printer 94. Error Message HNZ2001 SIA Printer 95. Error Ended HNZ2001 SIA Printer 96. Status: Mains Power Failure SIA Printer 97. Status: Battery Broken SIA Printer 156 Display
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 79
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F9
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7A
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FA
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 7B
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY FB
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7C
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FC
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7D
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FD
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7E
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FE
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 XX XX FF
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 01 YY XX 42
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 01 YY XX C2
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 32
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 33 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix H: RB2000 Messages (D6600 Only) . Table 110: RB2000 Messages (continued) # Event 98. Status: Battery Empty 99. Status: Signed Out 100. Remote Programming Request Device/ Mode SIA Printer SIA Printer SIA Printer Display
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 37
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 71
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 10 00 xx yy 70 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 157 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Appendix I: SafeCom Messages (D6600 Only) In D6500 Mode, the line number sent to the computer is only one digit. Refer to Table 111. If Virtual Line is 00, it is disabled. The D6600 reports the actual D6600 line card number. Table 111: Virtual Line Conversion Table Line# 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 Converted to D6500 SIA 1 01 2 02 3 03 4 04 5 05 6 06 7 07 8 08 9 09 A 0a B 0b C 0c D 0d E 0e F 0f G 10 H 11 I 12 Line# 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 FF Converted to D6500 SIA J 13 K 14 L 15 M 16 N 17 O 18 P 19 Q 1a R 1b S 1c T 1d U 1e V 1f W 20 X 21 Y 22 Y 22 Y 22 For D6500 Mode, any Virtual Line greater than or equal to 22 is reported as Y. For SIA Mode, any Virtual Line greater than or equal to 22 is reported as 22. 158 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 112: SafeCom Messages - Line Card or Account Signals # Event Device/ Mode Display 1. System Startup 6500 SIA1 hprrl00000100t
[#0000|0100] Printer2 dd/dd tt:tt Sxx SYSTEM STARTUP 6500 SIA1 hprrl0aaa0100t
[#0aaa|0100] 2. Radio Restart Printer 3. 4. Battery Trouble Battery Restoral 6. Aux. Fault Aux. Restoral hprrl0aaa0103t
[#0aaa|0103] Printer2 dd/dd tt:tt Sxx aaa>BATTERY TROUBLE 6500 SIA1 hprrl0aaa0104t
[#0aaa|0104] 8. 9. 10. AC Trouble AC Restoral External Power Fail External Power Restoral 12. Remote Com Restore RF Trouble Printer2 dd/dd tt:tt Sxx aaa>AUX FAULT 6500 SIA1 hprrl0aaa0104t
[#0aaa|0104] 14. RF Restore System RF Channel Busy 2 hprrl0aaa0105t
[#0aaa|0105] Printer2 dd/dd tt:tt Sxx aaa>AC TROUBLE 6500 SIA1 hprrl0aaa0106t
[#0aaa|0106] Printer2 dd/dd tt:tt Sxx aaa ac restore 6500 SIA1 hprrl0aaa0105t
[#0aaa|0105] Printer2 dd/dd tt:tt Sxx aaa>POWER TROUBLE 6500 SIA1 hprrl0aaa0106t
[#0aaa|0106] 2 dd/dd tt:tt Sxx aaa power restore 6500 SIA1 hprrl0aaa0110t
[#0aaa|0110] Printer2 dd/dd tt:tt Sxx aaa>REMOTE COM RESTORE 6500 SIA1 hprrl0aaa0111t
[#0aaa|0111] 2 Only valid for DP1000, PID-FE10 Only valid for DP1000, PID-FE10 dd/dd tt:tt Sxx aaa aux restore 6500 SIA1 Printer 13. dd/dd tt:tt Sxx aaa battery restore hprrl0aaa0103t
[#0aaa|0103] Printer 11. 2 6500 SIA1 Printer 7. dd/dd tt:tt Sxx aaa>restart 6500 SIA1 Printer 5. 2 Notes on Auto Output SC3100 PID-0330 or 0340, SC2104 PID-0430 or 0440 SC3100 PID-0330 or 0340, SC2104 PID-0430 or 0440 This indicates that the radio could not report a previous message (until just now). dd/dd tt:tt Sxx aaa>RF TROUBLE 6500 SIA1 hprrl0aaa0112t
[#0aaa|0112] Printer2 dd/dd tt:tt Sxx aaa rf restore 6500 SIA1 hprrl00000111t
[#0000|0111] Printer2 dd/dd tt:tt Sxx CHn>CHANNEL BUSY 1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164. 2 - Refer to Table 115 Explanation of Printer Output Items on page 165. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 159 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Table 112: SafeCom Messages - Line Card or Account Signals (continued) # Event Device/ Mode Display 15. System RF Channel Clear 6500 SIA1 hprrl00000112t
[#0000|0112] Printer2 dd/dd tt:tt Sxx CHn channel clear 6500 SIA1 hprrl0aaa0121t
[#0aaa|0121] Printer2 dd/dd tt:tt Sxx aaa>CHANNEL BUSY 6500 SIA1 hprrl0aaa0122t
[#0aaa|0122] Printer2 dd/dd tt:tt Sxx aaa channel clear 6500 SIA1 hprrl0aaa022000t
[#0aaa|022000] Printer2 dd/dd tt:tt Sxx aaa>DIALER ERROR e 16. 17. 18. Channel Busy Channel Clear Dialer Error Notes on Auto Output “e” is error code. See below for details: 0 - unknown error 1 - dialing error 2 - handshake error 3 - noise error 19. 20. 21. 22. 23. 24. 25. 26. Tamper Fault Tamper Restore Phone Line Fail Phone Line Restore Aux. Power Fail Aux. Power Restore Fire Panic Burglary Panic 4 - unexpected disconnect 5 - validation error 6 - priority error 6500 SIA1 hprrl0aaa03200301t
[#0aaa|03200301] Printer2 dd/dd tt:tt Sxx aaa>TAMPER FAULT 6500 SIA1 hprrl0aaa03200101t
[#0aaa|03200101] Printer2 dd/dd tt:tt Sxx aaa tamper restore 6500 SIA1 hprrl0aaa03200301t
[#0aaa|03200301] Printer2 dd/dd tt:tt Sxx aaa>TELCO TROUBLE 6500 SIA1 hprrl0aaa03200101t
[#0aaa|03200101] Printer2 dd/dd tt:tt Sxx aaa telco restore 6500 SIA1 hprrl0aaa03200301t
[#0aaa|03200301] Printer2 dd/dd tt:tt Sxx aaa>AUX POWER TROUBLE 6500 SIA1 hprrl0aaa03200101t
[#0aaa|03200101] Printer2 dd/dd tt:tt Sxx aaa aux power restore 6500 SIA1 hprrl0aaa03200302t
[#0aaa|03200302] Printer2 dd/dd tt:tt Sxx aaa>FIRE PANIC 6500 SIA1 hprrl0aaa03200303t
[#0aaa|03200303] Printer 2 Dialer error is reported to automation in a format similar to 3-1 event. Only valid for SC2104 Only valid for SC2104 Only valid for SC5000 Only valid for SC5000 Only valid for SC5000 Only valid for SC5000 dd/dd tt:tt Sxx aaa>BURGLARY PANIC 1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164. 2 - Refer to Table 115 Explanation of Printer Output Items on page 165. 160 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 112: SafeCom Messages - Line Card or Account Signals (continued) # Event Device/ Mode Display Notes on Auto Output 27. Silent/Medical Panic 6500 SIA1 hprrl0aaa03200304t
[#0aaa|03200304] Only valid for SC5000 Printer2 dd/dd tt:tt Sxx aaa>SILENT/MEDICAL PANIC 6500 SIA1 hprrl0aaa03200305t
[#0aaa|03200305] 28. Operator Evacuation Bell Printer 29. 30. Input Normal Input Open 32. Input Short Input Bypass hprrl0aaa0320011it
[#0aaa|0320011i] Printer2 dd/dd tt:tt Sxx aaa normal: input i 6500 SIA1 hprrl0aaa0320021it
[#0aaa|0320021i] 34. 35. 36. Input Unbypass Zone Restore Zone Trouble Fire Alarm 38. Silent Alarm Burglary Alarm Printer2 dd/dd tt:tt Sxx aaa>SHORTED: input i 6500 SIA1 hprrl0aaa0320041it
[#0aaa|0320041i] 40. Zone Bypass Zone Unbypass 2 dd/dd tt:tt Sxx aaa bypass: input i 6500 SIA1 hprrl0aaa0320051it
[#0aaa|0320051i] Printer2 dd/dd tt:tt Sxx aaa unbypass: input i 6500 SIA1 hprrl0aaa0320011zt
[#0aaa|0320011z] Printer2 dd/dd tt:tt Sxx aaa restore: zone z 6500 SIA1 hprrl0aaa0320021zt
[#0aaa|0320021z] Printer2 dd/dd tt:tt Sxx aaa>TROUBLE: zone z 6500 SIA1 hprrl0aaa0320031zt
[#0aaa|0320031z] 2 dd/dd tt:tt Sxx aaa>FIRE: zone z 6500 SIA1 hprrl0aaa0320031zt
[#0aaa|0320031z] Printer2 dd/dd tt:tt Sxx aaa>SILENT: zone z 6500 SIA1 hprrl0aaa0320031zt
[#0aaa|0320031z] Printer 39. dd/dd tt:tt Sxx aaa>OPENED: input i hprrl0aaa0320031it
[#0aaa|0320031i] Printer 37. 2 6500 SIA1 Printer 33. dd/dd tt:tt Sxx aaa>OPERATOR EVACUATION 6500 SIA1 Printer 31. 2 2 dd/dd tt:tt Sxx aaa>BURGLARY: zone z 6500 SIA1 hprrl0aaa0320041zt
[#0aaa|0320041z] Printer2 dd/dd tt:tt Sxx aaa BYPASS: zone z 6500 SIA1 hprrl0aaa0320051zt
[#0aaa|0320051z] Printer 2 Only valid for SC5000 Only valid for SC5000 Only valid for SC5000 Only valid for SC5000, depending on the zone type Only valid for SC5000, depending on the zone type Only valid for SC5000, depending on the zone type Only valid for SC5000 Only valid for SC5000 dd/dd tt:tt Sxx aaa unbypass: zone z 1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164. 2 - Refer to Table 115 Explanation of Printer Output Items on page 165. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 161 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Table 112: SafeCom Messages - Line Card or Account Signals (continued) # Event Device/ Mode Display Notes on Auto Output 41. Operator Armed 6500 SIA1 hprrl0aaa03200600t
[#0aaa|03200600] Only valid for SC5000 Printer2 dd/dd tt:tt Sxx aaa OPERATOR ARMED 6500 SIA1 hprrl0aaa0320060ut
[#0aaa|0320060u] 42. User Armed Printer 43. 44. Operator Disarmed User Disarmed 46. User Duress Operator Cancel hprrl0aaa03200700t
[#0aaa|03200700] Printer2 dd/dd tt:tt Sxx aaa>OPERATOR DISARMED 6500 SIA1 hprrl0aaa0320070ut
[#0aaa|0320070u] User Cancel 2 hprrl0aaa0320080ut
[#0aaa|0320080u] Printer2 dd/dd tt:tt Sxx aaa>DURESS: user u 6500 SIA1 hprrl0aaa03200900t
[#0aaa|03200900] 2 Only valid for SC5000 Only valid for SC5000 dd/dd tt:tt Sxx aaa>DISARMED: user u 6500 SIA1 Printer 47. dd/dd tt:tt Sxx aaa ARMED: user u 6500 SIA1 Printer 45. 2 Only valid for SC5000 Only valid for SC5000 Only valid for SC5000 dd/dd tt:tt Sxx aaa OPERATOR CANCEL 6500 SIA1 hprrl0aaa0320090ut
[#0aaa|0320090u] Printer2 dd/dd tt:tt Sxx aaa CANCEL: user u Only valid for SC5000 1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164. 2 - Refer to Table 115 Explanation of Printer Output Items on page 165. Table 113: SafeCom Messages - Intercepted Control Panel Signals # Event Device/ Mode Display 48. 3-1 Unexpanded 6500 SIA1 hprrlaaaa0220e0t
[#aaaa|0220e0] Printer 49. 50. 51. 2 dd/dd tt:tt Sxx aaa>(aaaa) e XXXXXXXX 3-1 Expanded, 4-2, BFSK, or Ademco 42 Express 6500 SIA1 hprrlaaaa0220ezt
[#aaaa|0220ez] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) ez XXXXXXXX FBI SuperFast 6500 SIA1 hprrlaaaa0321ezzet
[#aaaa|0321ezze] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX 6500 SIA1 hprrlaaaa0620eeeeeeeet0t
[#aaaa|0620eeeeeeeet0] Ademco 4-9 High Speed Printer 2 dd/dd tt:tt Sxx aaa>(aaaa) eeee eeee t 1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164. 2 - Refer to Table 115 Explanation of Printer Output Items on page 165. 162 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 113: SafeCom Messages - Intercepted Control Panel Signals (continued) # Event 52. Ademco Contact ID 53. 54. 55. 56. 57. 58. 59. 60. 61. SIA DCS Modem II - PID 0x50 Device/ Mode 6500 SIA1 Printer2 6500 SIA1 Printer2 6500 SIA1 Printer2 Modem II - PID 0x72, Unexpanded, without Status Report 6500 SIA1 Printer2 Modem II - PID 0x72, Unexpanded, with Status Report 6500 SIA1 Printer2 Modem II - PID 0x72, Expanded, without Status Report 6500 SIA1 Printer2 Modem II - PID 0x72, Expanded, with Status Report 6500 SIA1 Printer2 Modem II - PID 0xBB 6500 SIA1, 3 Printer2 Modem IIe/IIIa2 Modem IIe/IIIa2 with 4-Digit Zone 6500 SIA1, 3 Printer2 6500 SIA1, 3 Printer2 Display hprrlaaaa072018qeeeggccc0t
[#aaaa|072018qeeeggccc0] dd/dd tt:tt Sxx aaa>(aaaa) qeee gg czzz >>>>>>>>>>>>>>> aaa>qeeeTTTTTTTTXXXXXXXX hprrlaaaa0f20ffeeeezzzzzz0000000000000000t
[#aaaa|0f20ffeeeezzzzzz0000000000000000] dd/dd tt:tt Sxx aaa>(aaaa) feezzz hprrlaaaa03231ezzt
[#aaaa|03231ezz] dd/dd tt:tt Sxx aaa>(aaaa) ezz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0322ez00t
[#aaaa|0322ez00] dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0322ez00t
[#aaaa|0322ez00] dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>STATUS:XXXXXXXX hprrlaaaa0322ezzzt
[#aaaa|0322ezxx] dd/dd tt:tt Sxx aaa>(aaaa) e zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0322ezzzt
[#aaaa|0322ezzz] dd/dd tt:tt Sxx aaa>(aaaa) e zxx >>>>>>>>>>>>>>> aaa>STATUS:XXXXXXXX hprrlaaaa0621aaeezzz000t
[#aaaa|0621aaeezzz000] dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0621aaeezzz000t
[#aaaa|0621aaeezzz000] dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX hprrlaaaa0622aaeezzzz00t
[#aaaa|0622aaeezzzz00] dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzzz >>>>>>>>>>>>>>> aaa>XXXXXXXX 1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164. 2 - Refer to Table 115 Explanation of Printer Output Items on page 165. 3 - Refer to Table 116 Supported Event Codes on page 166 Bosch Security Systems, Inc. | 9/07 | 4998122703-02 163 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Table 114: Explanation of Automation Output Items (within Message Body only) Character aaa i z u aaaa e ee eee eeee eeeeeeee t z zz zzz zzzz zzzzzz gg ff aa q ccc 164 Meaning Radio account number (in hex), range: 001 to 9C4. Input number, range: 1 to 8. Zone number, range: 1 to 8. User number, range: 1 to 8. Control panel account number. Event code. Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only). Type code. Zone (or contact) code. Group number. Function code. Area code. Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message) (Ademco Contact ID only). Hex contact or user code. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 115: Explanation of Printer Output Items Character dd/dd tt:tt S xx n aaa > e i z u (aaaa) e ee eee eeee eeee t z zz zzz gg f aa XXXXXXXX TTTTTTTT q Meaning Month and day (MM/DD). Time of message receipt (HH:MM). SafeCom Line card number, range: 01 to 08. Radio channel number, range: 1 to 8. Radio account number (in hex), range: 001 to 9C4. If exists, the signal is in high priority. Error code (for dialer error signals only), range: 0 to 6. Input number, range: 1 to 8. Zone number, range: 1 to 8. User number, range: 1 to 8. Control panel account number. Event code. Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only). Type code. Zone (or contact) code. Group number. Function code. Area code. Translation text embedded (only when valid digital XLAT is selected for the radio account). Event type can be NEW, RESTORE, or PRIOR (Ademco Contact ID only). Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message) (Ademco Contact ID only). Bosch Security Systems, Inc. | 9/07 | 4998122703-02 165 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Modem IIe Format DD/MM HH:MM:SS NNN > (DDDD) AA EE ZZZ Modem IIe messages are reported as AA EE ZZZ where AA is the area code, EE is the event code from Table 116, and ZZZ is the zone or user code. For example: 01 EF 009 = area 1, alarm zone 9. Table 116: Supported Event Codes Code FE FD FC FB FA F9 F8 F7 F6 F5 F4 F3 F2 F1 F0 EF EE ED EC EB EA E9 E8 E7 E6 E5 E4 E3 E2 E1 E0 DF DE DD DC DB DA D9 D8 D7 D6 D5 166 Meaning Listen in. Fail to call RAM. Access granted. Duress user ZZZ. User ZZZ alarm 7. User ZZZ alarm 9. Point ZZZ bypass. Point ZZZ forced bypass. Status = alarm ZZZ. Status = trouble ZZZ. Fire alarm ZZZ. Fire trouble ZZZ. Missing fire ZZZ. Fire restore ZZZ. Fire trouble restore ZZZ. Alarm ZZZ. Trouble ZZZ. Restore ZZZ. Missing alarm ZZZ. Missing trouble ZZZ. Point ZZZ open. Point ZZZ close. Extra point ZZZ. Point bus trouble. All points tested. Restoral from alarm. Fire cancel. User code added. Service start. Service end. Sensor ZZZ reset. Relay ZZZ set. Relay ZZZ reset. Panel was forced armed. Create status report. Fire walk start by user ZZZ. Fire walk end. Walk test start by user ZZZ. Walk test end. Fail to open. Fail to close. Area watch by user ZZZ. Code D4 D3 D2 D1 D0 CF CE CD CC CB CA C9 C8 C7 C6 C5 C4 C3 C2 C1 C0 BF BE BD BC BB BA B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 AF AE AD AC AB Meaning Walk test point. Extend close time by user ZZZ. Cancel by user ZZZ. Status = open. Open by user ZZZ. Force close by user ZZZ. Status = closed. Close by user ZZZ. Test report. Log at threshold. Log overflow. Parameter change. User code tamper by user ZZZ. User code for user ZZZ added or changed. Sked ZZZ execute. Sked ZZZ changed. Date changed by user ZZZ. Time changed by user ZZZ. User level set by user ZZZ. Valid programmer access by SDI device ZZZ. Invalid programmer access by SDI device ZZZ. Valid RAM access on phone ZZZ. Invalid RAM access on phone ZZZ. Comm fail phone ZZZ. Comm restore phone ZZZ. Phone line ZZZ fail. Phone line ZZZ restore. SDI device ZZZ trouble. SDI device ZZZ restore. Panel AC fail. Panel AC restore. Panel battery missing. Panel battery low. Panel battery restore. Panel watchdog activated. Supervision (non-fire) ZZZ. Remote reset. ROM checksum failure. Memory failure. Reboot Parameter checksum failure. Force perimeter instant by user ZZZ. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Conettix D6600/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 116: Supported Event Codes Code AA A9 A8 A7 A6 A5 A4 A2 A1 A0 9F 9A 99 98 95 94 92 91 90 8F 8E 8D 8C 8B 8A 89 88 87 86 85 84 83 82 81 7F 7E 7D 7C Meaning Force perimeter delay by user ZZZ. Status = perimeter instant. Status = perimeter delayed. Perimeter instant by user ZZZ. Perimeter delayed by user ZZZ. Passcode for user ZZZ deleted. Point bus restore. Transmitter point ZZZ battery low. Transmitter point ZZZ battery restore. Transmitter point ZZZ tamper restore. RF receiver trouble by SDI device ZZZ. Extra RF point ZZZ. RF receiver restore by SDI device ZZZ. RF interference by SDI device ZZZ. Transmitter point ZZZ tamper alarm. Transmitter point ZZZ tamper trouble. Equipment restoral by SDI device ZZZ. Card assigned by user ZZZ. Card deleted by user ZZZ. Door cycled point ZZZ. Door unlocked point ZZZ. Door locked point ZZZ. No entry point ZZZ. Door left open point ZZZ. Door request point ZZZ. Network failure path ZZZ. Network restoral path ZZZ. Network condition path ZZZ. Equipment fail by SDI device ZZZ. Status supervision point ZZZ. Fire Supervision Restoral point ZZZ. Fire supervision point ZZZ. Fire Supervision Trouble point ZZZ. Fire Supervision Trouble Restoral point ZZZ. Status fire supervision point ZZZ. Extra account path ZZZ. Low signal strength path ZZZ. RF receiver tamper by SDI device ZZZ. Bosch Security Systems, Inc. | 9/07 | 4998122703-02 Code 7B 7A 79 78 77 76 75 74 73 72 71 70 6F 6E 6D 6C 6B 6A 69 68 5F 5E 5D 5C 5B 5A 59 58 56 55 54 53 52 51 50 4F 4E Meaning RF receiver tamper restoral by SDI device ZZZ. Status fire alarm point ZZZ. Status fire trouble point ZZZ. RF interference restoral by SDI device ZZZ. Status RF trans low battery point ZZZ. Status RF trans tamper alarm point ZZZ. Status RF trans tamper trouble point ZZZ. Sensor Trouble point ZZZ. Sensor Trouble Restoral point ZZZ. Status fire missing point ZZZ. Status missing alarm point ZZZ. Status missing trouble point ZZZ. Status door forced point ZZZ. Door locked point ZZZ. Missing fire supervision point ZZZ. Missing supervision point ZZZ. Status missing fire supervision point ZZZ. Status missing supervision point ZZZ. Status door left open point ZZZ. Failed to execute point ZZZ. Analog service point ZZZ. Analog restoral point ZZZ. Status analog service point ZZZ. Test Failed path ZZZ. External device ZZZ. Custom Function ZZZ Executed. Low Temperature point ZZZ. Low Temperature Restoral point ZZZ. Unverified Event point ZZZ. Printer Status by SDI device ZZZ. Abort by user ZZZ. Service Request. Output ZZZ State. Output ZZZ State Restoral. Bypass Restoral point ZZZ. Alarm Silenced point ZZZ. Alarm-Panel Substitution path ZZZ. 167 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 (800) 289-0096 © 2007 Bosch Security Systems, Inc. 4998122703-02