Preview only show first 10 pages with watermark. For full document please download

Da - 11674 - Worldwide

   EMBED


Share

Transcript

QuickSpecs Cisco MDS 9509 Multilayer Director Overview DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 1 QuickSpecs Cisco MDS 9509 Multilayer Director Overview Models Cisco MDS 9509 Director, Base Unit w/0 ports 332306-B21 Cisco MDS 9000 Series 16-port Card 332307-B21 Cisco MDS 9000 Series 32-port Card 332308-B21 2500W AC Power Supply for MDS 9509 333739-B21 2500W DC Power Supply for MDS 9509 332309-B21 4000W AC Power Supply for MDS 9513, US 332310-B21 4000W AC Power Supply for MDS 9513, Int'l 332311-B21 MDS 9500 Sup Compact Flash Disk, 512 MB 332314-B21 Transceivers, Small-Form-Factor-Pluggable, Short Wave 332312-B21 Transceivers Small-Form-Factor-Pluggable, Long Wave 332313-B21 MDS 9000 Port Analyzer Adapter 332317-B21 Cisco MDS 9509 Installation Service HA113A1 #5D1 Introduction The Cisco MDS 9509 Multilayer Director delivers multiple layers of intelligence, including multi-protocol support (Fibre Channel, iSCSI, FCIP), Virtual SANs (VSANs), embedded diagnostics and role-based security. With these innovations, companies can build highly scalable, available storage networks with comprehensive security and unified management. The MDS 9509 delivers industry-leading performance (1.44 Terabits internal system throughput), port density (up to 224-ports) and high availability, to lower TCO and enable integrated SAN infrastructures. MDS 9000 Modules, including 16- and 32-port 1 or 2 Gb Fibre Channel Switching Modules and an 8-port IP Services Module, are interchangeable across MDS 9000 Directors and Fabric Switches, providing a smooth migration path, common sparing and investment protection. Integrated management, including an embedded Fabric Manager and integration with HP OpenView-SAM and CiscoWorks RME, provide ease of administration to improve customer productivity. HP delivers the Cisco MDS 9509 Multilayer Director with high availability features designed in. The base unit includes a 9 slot modular chassis with dual supervisor modules to help ensure smooth, continuous operation and non-disruptive upgrade capability. DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 2 QuickSpecs Cisco MDS 9509 Multilayer Director Standard Features Feature List Modular Director 9 slots High Port Density 16 – 224 Fibre Channel ports (auto-sensing 2/1 Gb) in single chassis 672-ports in standard rack (42U) High Availability Non-disruptive software upgrades Stateful process restart/failover Redundancy of all major components Hot swappable components Intelligent Network Services Virtual SANs (VSANs) PortChannels QoS Embedded Diagnostics: Fibre Channel Ping and Trace route, Embedded Fibre Channel protocol analyzer, SPAN, zone and VSAN merge analysis, system health monitoring, Call Home Security: role-based access control, access control lists, hardware-enforced zoning, co-authored ANSI T11 draft standard FC-SP, SNMPv3, RADIUS Multi-protocol Support Fibre Channel (auto-sensing 2/1 Gb) iSCSI FCIP High Performance 1.44 Terabit/sec internal system throughput 10 Gb ready Open Platform Enabling Network-based Intelligent Storage Applications Virtualization, data replication, back-up Integrated Management Embedded Fabric Manager Integration with HP OpenView-SAM Integration with CiscoWorks Resource Manager Essentials (RME) Customer benefits include Controllable Manageable: Manageable provides embedded Fabric Manager and integration with HP OpenView -SAM and CiscoWorks RME Serviceable: Serviceable delivers embedded diagnostics (Fibre Channel ping, traceroute and protocol analyzer) and "Call Home" Upgradable: Upgradable offers investment protection with multiple module options, all interchangeable across MDS 9000 line Resilient High availability: provides nondisruptive software upgrades, stateful process failover and hot swappable components Secure: Secure supports VSANs, hardware-enforced zoning, role-based access control, FC-SP, and access control lists Extensible Multi-protocol: Multi-protoco integrates Fibre Channel, iSCSI, and FCIP in one system Flexible: Flexible introduces Virtual SANs (VSANs) for consolidation of isolated SAN islands on a single physical fabric Scalable: Scalable offers16 to 224 Fibre Channel ports; supports throughput up to 32 Gb in a single PortChannel ISL High performance: performance supplies 1.44 Terabits/sec of internal throughput ensuring readiness for future 10 Gb integration Open: Open provides open platform for hosting 3rd party storage applications, such as virtualization Interoperable: Interoperable offers compatibility with a broad range of HP servers and operating systems, as well as disk and tape storage devices Product Family Models: Cisco MDS 9509 Multilayer Director - Intelligent, multi-protocol 9-slot Director with up to 224 Auto-Sensing 2/1 Gb Fibre Channel ports - Cisco MDS 9216 Multilayer Fabric Switch - Intelligent, multi-protocol modular Fabric Switch with up to 48 Auto-Sensing 2/1 Gb Fibre Channel ports Cisco MDS 9216 Multilayer Fabric Switch - Intelligent, multi-protocol modular Fabric Switch with up to 48 Auto-Sensing 2/1 Gb Fibre Channel ports DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 3 QuickSpecs Cisco MDS 9509 Multilayer Director Standard Features Key Features Modular, scalable Director – 9 slots High port density – 16-224 Auto-Sensing 2/1 Gb Fibre Channel ports in a single chassis and 672-ports in a single rack High Availability Multi-protocol Support – Fibre Channel, iSCSI, FCIP High Performance – 1.44 Terabit/sec internal system throughput ensure 10-Gbps readiness Virtual SANs (VSANs) PortChannels QoS Embedded Diagnositcs – Fibre Channel ping and trace route, protocol analysis and decoding, SPAN, Call Home capability Security – RBACs, ACLs, hardware, enforced Zoning, FC-SP, SNMPv3, RADIUS Open Platform for Enabling Network-based Intelligent Storage Applications Integrated Management – embedded Fabric Manager, integration with HP OpenView -SAM and CiscoWorks RME Common architectural platform across Cisco MDS 9500 Directors and Cisco MDS 9216 Fabric Switch; interchangeable modules across Directors and Fabric Switches Modular, Scalable 2-slot Fabric Switch Supports from 16 to 224 auto-sensing 2 / 1-Gb Auto-Sensing Fibre Channel ports and from 8 to 48 1-Gb Ethernet ports (user configurable for iSCSI or FCIP) in a single chassis and up to 672 Fibre Channel ports in a single rack. Investment Protection Shares common switching modules across all Cisco MDS 9500 Series Director products as well as the MDS 9216 Multilayer Fabric Switch. High Availability Combines non-disruptive software upgrades, stateful process restart/failover, and full redundancy of all major components for a new standard in director-class availability. High Performance 1.44 Terabits/sof internal system bandwidth ensures smooth integration of future 10 Gb modules. Multiprotocol/ Multitransport The multilayer architecture of the Cisco MDS 9509 enables a consistent feature set over a protocol agnostic switch fabric; seamlessly integrates Fibre Channel, iSCSI, and FCIP in one system. Flexible architecture allows integration of future storage protocols. Virtual SANs (VSANs) Hardware-enforced, isolated environments within a single physical fabric for secure sharing of physical infrastructure. Access Control Lists (ACLs) Hardware-based intelligent frame processing. PortChannels Allows users to aggregate up to 16 physical links into one logical bundle. The bundle can consist of any port in the chassis, ensuring that the bundle remains active in the event of a port, ASIC, or module failure. The bundle can sustain the failure of any physical link without causing a reset. Additionally, Fabric Shortest Path First (FSPF) multi-pathing provides the intelligence to load balance across up to 16 equal cost paths and, in the event of a switch failure, to dynamically reroute traffic. Embedded Diagnostics Provides industry-first intelligent diagnostics, including Fibre Channel ping and trace route, SPAN, protocol analysis and decoding, Zone and VSAN merge analysis, and integrated Call Home capability. Comprehensive Security Framework Supports role-based access control, VSANs, hardware-enforced Zoning, FC-SP, ACLs, RADIUS authentication, SNMPv3, SSH, and SFTP. DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 4 QuickSpecs Cisco MDS 9509 Multilayer Director Standard Features Open Platform for Intelligent Storage Services Provides an open platform for hosting intelligent storage services such as network-based virtualization and replication. Integrated Management Includes built-in storage network management with all features available via CLI or Cisco Fabric Manager, a centralized management tool that simplifies management of multiple switches and fabrics. Also provides integration with HP OV-SAM and Cisco Resource Manager Essentials (RME). Interoperabililty Offers compatibility with a broad range of HP servers and operating systems, as well as disk and tape storage devices; see current compatibility matrix Serviceability Delivers embedded diagnostics (Fibre Channel ping, traceroute and protocol analyzer) and "Call Home" capabilities Warranty 1-year labor and parts, 8 x 5, next-business-day response DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 5 QuickSpecs Cisco MDS 9509 Multilayer Director Options Optical Cables Recommended Cables FC Cable 2m Duplex LC/LC 50/125 M/M Optical C7524A FC Cable 16m Duplex LC/LC 50/125 M/M Optical C7525A FC Cable 50m Duplex LC/LC 50/125 M/M Optical C7526A FC Cable 200m Duplex LC/LC 50/125 M/M Optical C7527A FC Cable 2m LC/SC 50/125 M/M Optical C7529A FC Cable 16m LC/SC 50/125 M/M Optical C7530A FibreC Adapter SC/SC 50/125 F/F C7534A Fibre Channel Adapter Cable Kit – Optical C7540A Alternative Cables (LC-LC for between two 2 Gb devices) 2m LC-LC Multi-Mode Fibre Channel Cable 221692-B21 5m LC-LC Multi-Mode Fibre Channel Cable 221692-B22 15m LC-LC Multi-Mode Fibre Channel Cable 221692-B23 30m LC-LC Multi-Mode Fibre Channel Cable 221692-B26 50m LC-LC Multi-Mode Fibre Channel Cable 221692-B27 (LC-SC for between a 1 Gb/s and a 2 Gb/s device) 2m LC-LC Multi-Mode Fibre Channel Cable 221691-B21 5m LC-LC Multi-Mode Fibre Channel Cable 221691-B22 15m LC-LC Multi-Mode Fibre Channel Cable 221691-B23 30m LC-LC Multi-Mode Fibre Channel Cable 221691-B26 50m LC-LC Multi-Mode Fibre Channel Cable 221691-B27 Software Components SAN-OS Includes Cisco Fabric Manager software DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 6 QuickSpecs Cisco MDS 9509 Multilayer Director Service and Support and Warranty Information Increased Warranty Options Increased warranty options are available, including 1- and 3-year on-site, next-day, same-day 4 hour response, 13 x 5 and 24 x 7, hardware and software phone support. For more information on warranty and support options, please visit our web site at: http://www.hp.com/hps/tech/storage/supp/ Installation and Support Services Installation service; SAN Solution service; SAN-Environmental Support service; SAN Architecture service H9162A; Proactive 24. For more information on these and other service options, please contact any of our worldwide sales offices or visit our web site at: http://www.hp.com/hps/support Contact Information For more information on HP SAN switches, contact any of our worldwide sales offices or visit our Web site at: http://www.hp.com/go/san DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 7 QuickSpecs Cisco MDS 9509 Multilayer Director Configuration Information Step 1 – Base Configuration Model Description Model Number MDS 9509 base unit includes a 14U, Cisco MDS 9509 Director, Base Unit nine slot chassis, fans, dual supervisor w/0 ports modules, firmware and documentation. Supports up to seven optional expansion port modules. Part Number 332306-B21 Step 2 – Required Options Select each type of required options with quantities specified. Description with Parts Shipped Quantity 2500 watt AC Power Supply for MDS 9509 w/power cord OR 2 Part Number 333739-B21 2500 watt DC Power Supply for MDS 9509 OR 2 332309-B21 4000 watt AC Power Supply for MDS 9000 Series, US OR 2 332310-B21 4000 watt AC Power Supply for MDS 9000 Series, Int'l 2 332311-B21 NOTE: Appropriate country power cords will be included for the 2500 watt AC power supply for the MDS 9509 Director based on ship to destination information. Power supply types cannot be mixed on a single switch. Power cords will be supplied from the factory from the following list Description Power Cord, 250Vac 16A, straight blade NEMA 6-20 plug, US Power Cord, 250Vac 16A, Europe Power Cord, 250Vac 16A, INTL Power Cord, 250Vac 16A, twist lock NEMA L6-20 plug, US DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 8 QuickSpecs Cisco MDS 9509 Multilayer Director Configuration Information Step 3 – Additional Options Select each required option with quantities required. NOTE: Fibre Channel ports on the MDS 9000 series modules may be configured to accept either Short Wave SFP or Long Wave SFP optic transceivers. However, when ordering the MDS 9000 series modules, all available ports must be populated with the above SFP optic transceivers only. (No Substitutions) Optional switching modules are designed to be interchanged or shared between all Cisco MDS 9000 Directors and Fabric Switches. Description with Parts Shipped Quantity Part Number Cisco MDS 9000 Series 16-port Card * 332307-B21 Cisco MDS 9000 Series 32-port Card * 332308-B21 Optical Transceivers, Small Form Factor Pluggable, Short Wave * 332312-B21 Optical Transceivers, Small Form Factor Pluggable, Long Wave * 332313-B21 MDS 9000 Port Analyzer Adapter 332317-B21 MDS9500 Sup Compact Flash Disk, 512MB 332314-B21 * NOTE: Fibre Channel ports on the MDS 9000 series modules may be configured to accept either Short Wave SFP or Long Wave SFP optic transceivers. However, when ordering the MDS 9000 series modules, all available ports must be populated with the above SFP optic transceivers only. (No Substitutions) Optional switching modules are designed to be interchanged or shared between all Cisco MDS 9000 Directors and Fabric Switches. Step 4 – Installation Service Option Description with Parts Shipped Quantity Part Number Cisco MDS 9509 installation Service 1 per switch HA113A1#5D1 DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 9 QuickSpecs Cisco MDS 9509 Multilayer Director Technical Specifications Dimensions (HxWxD) (out-of-box, shipping) Description Out-of-box Shipping Base unit w/o ports 24.5x17.3x18.1(inches) (62.2x43.9x46.0 cm) 32x32x23 (inches) (81.3x81.3x58.4 cm) 16-port 1/2Gb FC Module 1.75x15.5x16.5(inches) (4.4x39.4x42 cm) 7.5x21.25x23 (inches) (19.1x54x58.4 cm) 32-port 1/2Gb FC Module 1.75x15.5x16.5(inches) (4.4x39.4x42 cm) 7.5x21.25x23 (inches) (19.1x54x58.4 cm) 2 Gb FC-SW SFP, LC 0.25 x0.5x2.5(inches) (0.6x1.3x6.4 cm) N/A 2 Gb FC-LW SFP, LC 0.25 x0.5x2.5(inches) (0.6x1.3x6.4 cm) N/A Sup Compact Flash Disk 1.375x 1.625 0.125(inches) (3.5x4.1x0.3 cm) N/A Port Analyzer Adapter 1.125x6x4.5(inches) (2.9x15.2x11.4 cm) 4x8x11 (inches) (10.2x20.32x28 cm) 2500W AC/DC 7.125x7.75x14.625(inches) (18.1x19.7x37.1cm) N/A 4000W AC, US/Int'l 7.125x7.75x14.625(inches) (18.1x19.7x37.1cm) N/A NOTES: NOTES 1. Dimension convention is as follows: H (Height) is the vertical dimension when looking at the front of the component, as it would be seen in the chassis. Exception is the compact flash where H is when looking at the identification label on the part. W (Width) is the horizontal (left to right) dimension when looking at the front of the component, as it would be seen in the chassis. Exception is the compact flash where W is when looking at the identification label on the part. D (Depth) is the front to back dimension when looking at the front of the component, as it would be seen in the chassis. Exception is the compact flash where D is when looking at the identification label on the part. 2. Packaging dimensions are reference as if you were looking at the front of the chassis in the packaging, if you could see through the packaging. Protocol Support Fibre Channel Protocols (FC-PH, Revision 4.3, FC-PH-2, Revision 7.4 FC-PH-3, Revision 9.4, FC-GS-2, Revision 5.3, FC-GS-3, Revision 7.01, FC-FLA, Revision 2.7, FC-FG, Revision 3.5, FC-SW-2, Revision 5.3, FC-AL, Revision 4.5, FC-AL-2, Revision 7.0 , FC-PLDA, Revision 2.1, FC-VI, Revision 1.61, FCP, Revision 12, FCP-2, Revision 7a, FC-SB-2, Revision 2.1, FC-BB, Revision 4.7, FC-FS, Revision 1.7, FC-PI, Revision 13 , FC-MI, Revision 1.99, FCTape, Revision 1.17) IP over Fibre Channel (RFC 2625) Extensive IETF-standards based TCP/IP, SNMPv3, and RMON MIBs Class of Service: Class 2, Class 3, Class F Fibre Channel standard port types: E, F, FL Fibre Channel enhanced port types: SD, TE, TL Internet standards (RFC 791 IPv4, RFC 793, 1323 TCP, RFC 894 IP/Ethernet, RFC 1041 IP/802, RFC 792, 950, 1256 ICMP, RFC 1323 TCP performance enhancements, RFC 2338 VRRP) Ethernet standards (IEEE 802.3z Gigabit Ethernet, IEEE 802.1Q VLAN) O/S Support MDS SAN-OS Release 1.0(3) UPC Code 808736907897 DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 10 QuickSpecs Cisco MDS 9509 Multilayer Director Technical Specifications Connectors/Cables Connectors RJ-45 Interface Cable Connector LC-type-fiber optic SFP Cables RJ-45 to RJ-45 rollover cable RJ-45 to DB-25 female DTE adapter (labeled "Terminal ") RJ-45 to DB-9 female DTE adapter (labeled "Terminal ") RJ-45 to DB-25 male DCE adapter (labeled "Modem") LC-type cable LED Indicators (On Front Panel) Generic: - System - Ethernet (management) Switching Module: - Status - Speed - Link Fan: - Fan Status Enclosure LED Indicators (back of unit) Power Supply: - Input OK - Output OK - Output Fail Cable Type See Connectors/Cables Cable Lengths (Available) 6.6 feet (2 Meters), 16.4 feet (5 Meters), 15 Meters, 30 Meters and 50 Meters Input Requirements Nominal Line Voltage 2500W AC: 100 to 120 VAC, 200 to 240 VAC 2500W DC: -48 VDC to -60 VDC continuous 4000W AC: 200 to 240 VAC Range Line Voltage 2500W AC: 100 to 132 VAC, 200 to 264 VAC 2500W DC: N/A (±10% for full range) 4000W AC: 200 to 240 VAC Line Frequency 2500W AC: 50 to 60 Hz (nominal) (±3% for full range) 2500W DC: N/A 4000W AC: 50 to 60 Hz (nominal) (±3% for full range) Typical Input Current 2500W AC: 16A max at 200 VAC at 2500W output, 16A max at 100 VAC at 1300W output 2500W DC: 80 A 4000W AC: 23 A Interface 1/2 Gb FC ports 10/100 Mb Ethernet port (management) RS-232 RJ-45 console port DB-9 COM port DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 11 QuickSpecs Cisco MDS 9509 Multilayer Director Technical Specifications Maximum Number of Devices/Ports 224 FC ports 2 10/100 Mb Ethernet ports Maximum Transfer Rate 2 Gb/FC port Power 2500W AC and 2500W DC; plug types: International IEC 309 (20A), Europe CEE 7/7 (16A), North America (Non-locking) NEMA 6-20 plug (20A), North America (Locking) NEMA L6-20 plug (20A), Appliance coupler IEC 320 (16/20A) 4000W AC; plug types: International IEC 60309 (30A,250V), North America (locking) NEMA L6-30 plug (30A,250V) Power Supply Weight Each Cisco MDS 9500 AC-input power supply weighs between 22 lbs (9.9 kg) and 28 lbs (12.6 kg) Reliability Features Full redundancy of all major components for a new standard in director-class availability Stateful Supervisor Module failover Power-On Self Testing POST Error detection, fault isolation, parity checking, illegal address check Remote diagnostic through Call Home troubleshooting features Displayed LEDs Redundant Power Supply Relative Humidity (noncondensing) Operating 10 to 90%, ambient (non-condensing) operating Shipping 5 to 95%, ambient (non-condensing) non-operating and storage Temperature Range Operating 32 to 104°F (0 to 40°C), ambient operating Shipping -40 to 158°F (-40 to 70°C), ambient non-operating and storage Cisco MDS 9216 Cisco MDS 9509 Switch Type Multilayer Fabric Switch Multilayer Director Maximum ports 48 Fibre Channel ports 224 Fibre Channel ports Number of slots per chassis two nine Family Information © Copyright 2003 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 11674 Worldwide — Version 3 — September 16, 2003 Page 12