EG366, EG486 Document # PG04-001
Revised 05/06/10 Page 1/4
36 Inch and 48 Inch Wide Epicure® Gas Cooktops
Electric Circuit Requirements
warning •
•
PLANNING GUIDE
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
Circuit Required
Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
This appliance must be installed in accordance with the accompanying installation instructions.
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
Gas Supply Pressure Requirements* Gas Type
Manifold Pressure
Minimum Gas Supply Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 p.s.i.
IMPORTANT: Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486).
A
Combustible rear wall Product Dimensions - iSO VIEW
2 1/2” (64 mm) Min. to combustible rear wall
A - Width EG366
35 7/8” (911 mm)
EG486
47 7/8” (1216 mm)
28” (711 mm) 27” (686 mm) 26” (660 mm)
1 1/2” (38 mm) cooking surface height (grate level) above countertop
4” (102 mm)
Power cord 32” long
Trim: 7/16” (11 mm) thick
cabinet/countertop Side View without Backguard
7 3/4” (197 mm)
5/8” (16 mm)
Combustible rear wall Backguard mandatory if gap from back of cooktop to combustible wall is less than 2 1/2”
3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2” (51 mm) from chassis bottom Product Dimensions - Side View Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.
cabinet/countertop Side View with Backguard
www.Dacor.com
Phone: (800) 793-0093
4.1
EG366, EG486 Document # PG04-001
Revised 05/06/10 Page 2/4
36 Inch and 48 Inch Wide Epicure® Gas Cooktops
PLANNING GUIDE
Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) unless otherwise noted. 10” (254 mm) to combustible side wall Min. both sides
1 1/2” (38 mm) typical countertop thickness
1/2” (13 mm) overhang, both sides B
Cooktop platform 1” (25 mm) Min. thickness
7 3/4” (197 mm) Recommended gas and electrical service location, consult local code
36” (914 mm) typical
Cabinet/Countertop Dimensions - Front View 13” (330 mm) max.3
C
Model No.
Hood
B
C
EG366
36” (914 mm)
36” (914 mm)* 42” (1067 mm)**
EG486
48” (1219mm)
48” (1219 mm)* 54” (1372 mm)**
* Minimum ** Recommended See note 2
18” (457 mm) Min.1, 3
30” (762 mm) Min.1
Cutout for utility access
Top of finished counter
Cabinet/Countertop Dimensions ISO View
1 Vertical to combustible surface from cooktop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the cooktop.
Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.
www.Dacor.com
Continued on following pages...
Phone: (800) 793-0093
4.2
EG366, EG486 Document # PG04-001
Revised 05/06/10 Page 3/4
36 Inch and 48 Inch Wide Epicure® Gas Cooktops
PLANNING GUIDE
Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Gas and electrical connections at right rear section of chassis
Gas connection and power cord may be routed through bottom or back of chassis Increase countertop and overhang additional 2 1/2” (64 mm) Min. for combustible rear wall above countertop
Non-combustible rear wall, rear of mounting platform
10” (254 mm) min. to combustible wall above countertop, both sides
3/8” (13 mm) countertop overhang 1/2” (13 mm) countertop overhang
CL
1/2” (13 mm) countertop overhang Countertop
11 7/16” (291 mm)
Hole 1/2” dia. (13 mm), 2 places, through platform for hold down bolts
Countertop
24 5/8” (625 mm)
Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (203 mm X 152 mm), if gas and electrical are routed through bottom
1” thick mounting platform Min.
D
CL
2” (51 mm) 1” (25 mm)
D
CL
CL
Cabinet face below countertop overhang
B Cabinet/Countertop Cutout Dimensions without Raised Vent - Top View
Model No.
B - Cutout Width
D - Hole Offset
EG366
36” (914 mm)
16 5/8” (422 mm)
EG486
48” (1219 mm)
20 13/16” (529 mm)
Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.
www.Dacor.com
Phone: (800) 793-0093
4.3
EG366, EG486 Document # PG04-001
Revised 05/06/10 Page 4/4
36 Inch and 48 Inch Wide Epicure® Gas Cooktops
PLANNING GUIDE
Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
3/8” (10 mm) Min. countertop overhang
2 5/8” (67 mm)
Non combustible rear wall recommended
10” (254 mm) Min. to combustible wall above countertop, both sides
E Open to below to allow for raised vent, gas and electrical connections 1/2” (13 mm) countertop overhang
11 7/16” (291 mm)
Countertop
CL
Countertop
24 5/8” 15” (625 mm) (381 mm)
1/2” (13 mm) countertop overhang
1” thick mounting platform Min.
Hole 1/2” dia. (13 mm), 2 places, through platform for hold down bolts
2” (51 mm) 1” (25 mm) D
CL
D
CL
CL
Cabinet face below countertop overhang
B Cabinet/Countertop Cutout Dimensions with Raised Vent - Top View
3/8” Min. (10 mm) flat countertop overhang required behind cutout Countertop
Stiffener
Control panel Cabinet face
Dacor approved raised vent
Approved Raised Vent Models
EG366
ERV36, PRV36
EG486
ERV48, PRV48
IMPORTANT: Use only the raised vents specified.
EG366 or EG486 cooktop 3/8” Min. (10 mm) space behind raised vent chassis to clear stiffener
Model No.
Minimum countertop height: 30 1/4" (768 mm)
Model No.
B - Cutout Width
D - Hole Offset
E - Raised Vent Cutout
EG366
36” (914 mm)
16 5/8” (422 mm)
33 1/2” (851 mm)
EG486
48” (1219 mm)
20 13/16” (529 mm)
43 1/2” (1105 mm)
IMPORTANT: See raised vent installation instructions for duct system layout/planning
Cabinet/Countertop Cutout Dimensions with Raised Vent - side View Specifications subject to change without notice. Install all appliances according to accompanying installation instructions.
www.Dacor.com
Phone: (800) 793-0093
4.4