EG366, EG486 Document # PG04-001 Revised 05/06/10 Page 1/4 36 Inch and 48 Inch Wide Epicure® Gas Cooktops Electric Circuit Requirements warning • • PLANNING GUIDE Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Circuit Required Total Connected Load 120 Vac 60Hz, 15 Amp. (3 wire) 0.25 Amp @ 120 Vac, 60 Hz This appliance must be installed in accordance with the accompanying installation instructions. Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted Gas Supply Pressure Requirements* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5” Water Column 6” Water Column Propane (LP) 10” Water Column 11” Water Column * Maximum gas supply pressure for all models is 1/2 p.s.i. IMPORTANT: Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366), AEB4809 or AEB4812 (EG486). A Combustible rear wall Product Dimensions - iSO VIEW 2 1/2” (64 mm) Min. to combustible rear wall A - Width EG366 35 7/8” (911 mm) EG486 47 7/8” (1216 mm) 28” (711 mm) 27” (686 mm) 26” (660 mm) 1 1/2” (38 mm) cooking surface height (grate level) above countertop 4” (102 mm) Power cord 32” long Trim: 7/16” (11 mm) thick cabinet/countertop Side View without Backguard 7 3/4” (197 mm) 5/8” (16 mm) Combustible rear wall Backguard mandatory if gap from back of cooktop to combustible wall is less than 2 1/2” 3/4” gas inlet, connects to regulator from bottom or rear of unit, end is recessed 2” (51 mm) from chassis bottom Product Dimensions - Side View Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. cabinet/countertop Side View with Backguard www.Dacor.com Phone: (800) 793-0093 4.1 EG366, EG486 Document # PG04-001 Revised 05/06/10 Page 2/4 36 Inch and 48 Inch Wide Epicure® Gas Cooktops PLANNING GUIDE Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) unless otherwise noted. 10” (254 mm) to combustible side wall Min. both sides 1 1/2” (38 mm) typical countertop thickness 1/2” (13 mm) overhang, both sides B Cooktop platform 1” (25 mm) Min. thickness 7 3/4” (197 mm) Recommended gas and electrical service location, consult local code 36” (914 mm) typical Cabinet/Countertop Dimensions - Front View 13” (330 mm) max.3 C Model No. Hood B C EG366 36” (914 mm) 36” (914 mm)* 42” (1067 mm)** EG486 48” (1219mm) 48” (1219 mm)* 54” (1372 mm)** * Minimum ** Recommended See note 2 18” (457 mm) Min.1, 3 30” (762 mm) Min.1 Cutout for utility access Top of finished counter Cabinet/Countertop Dimensions ISO View 1 Vertical to combustible surface from cooktop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances. 2 See Cabinet/Countertop Dimensions - Top View 3 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the cooktop. Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Continued on following pages... Phone: (800) 793-0093 4.2 EG366, EG486 Document # PG04-001 Revised 05/06/10 Page 3/4 36 Inch and 48 Inch Wide Epicure® Gas Cooktops PLANNING GUIDE Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated Gas and electrical connections at right rear section of chassis Gas connection and power cord may be routed through bottom or back of chassis Increase countertop and overhang additional 2 1/2” (64 mm) Min. for combustible rear wall above countertop Non-combustible rear wall, rear of mounting platform 10” (254 mm) min. to combustible wall above countertop, both sides 3/8” (13 mm) countertop overhang 1/2” (13 mm) countertop overhang CL 1/2” (13 mm) countertop overhang Countertop 11 7/16” (291 mm) Hole 1/2” dia. (13 mm), 2 places, through platform for hold down bolts Countertop 24 5/8” (625 mm) Gas/electrical utility cut-out in right rear corner of mounting platform 8” W X 6” D (203 mm X 152 mm), if gas and electrical are routed through bottom 1” thick mounting platform Min. D CL 2” (51 mm) 1” (25 mm) D CL CL Cabinet face below countertop overhang B Cabinet/Countertop Cutout Dimensions without Raised Vent - Top View Model No. B - Cutout Width D - Hole Offset EG366 36” (914 mm) 16 5/8” (422 mm) EG486 48” (1219 mm) 20 13/16” (529 mm) Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 4.3 EG366, EG486 Document # PG04-001 Revised 05/06/10 Page 4/4 36 Inch and 48 Inch Wide Epicure® Gas Cooktops PLANNING GUIDE Cutout tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated 3/8” (10 mm) Min. countertop overhang 2 5/8” (67 mm) Non combustible rear wall recommended 10” (254 mm) Min. to combustible wall above countertop, both sides E Open to below to allow for raised vent, gas and electrical connections 1/2” (13 mm) countertop overhang 11 7/16” (291 mm) Countertop CL Countertop 24 5/8” 15” (625 mm) (381 mm) 1/2” (13 mm) countertop overhang 1” thick mounting platform Min. Hole 1/2” dia. (13 mm), 2 places, through platform for hold down bolts 2” (51 mm) 1” (25 mm) D CL D CL CL Cabinet face below countertop overhang B Cabinet/Countertop Cutout Dimensions with Raised Vent - Top View 3/8” Min. (10 mm) flat countertop overhang required behind cutout Countertop Stiffener Control panel Cabinet face Dacor approved raised vent Approved Raised Vent Models EG366 ERV36, PRV36 EG486 ERV48, PRV48 IMPORTANT: Use only the raised vents specified. EG366 or EG486 cooktop 3/8” Min. (10 mm) space behind raised vent chassis to clear stiffener Model No. Minimum countertop height: 30 1/4" (768 mm) Model No. B - Cutout Width D - Hole Offset E - Raised Vent Cutout EG366 36” (914 mm) 16 5/8” (422 mm) 33 1/2” (851 mm) EG486 48” (1219 mm) 20 13/16” (529 mm) 43 1/2” (1105 mm) IMPORTANT: See raised vent installation instructions for duct system layout/planning Cabinet/Countertop Cutout Dimensions with Raised Vent - side View Specifications subject to change without notice. Install all appliances according to accompanying installation instructions. www.Dacor.com Phone: (800) 793-0093 4.4