Preview only show first 10 pages with watermark. For full document please download

Danger - Lumascape

   EMBED


Share

Transcript

INSTALLATION INSTRUCTIONS Lumascape Lighting Industries Pty Ltd 38-44 Enterprise Street, Cleveland, QLD 4163, Australia PO Box 1875, Cleveland D.C., QLD 4163, Australia T 07 3286 2299 F 07 3286 6599 E [email protected] W www.lumascape.com.au UNDERWATER MODEL: LS265A-1 INPUT VOLTAGE: 12 V AC WATTAGE: 3 x 50 W MR16 G5.3 (when fully submersed) 3 x 20 W MR16 G5.3 (when not fully submersed or out of water) LS265A-1: Tristar Warranty voided if not installed as per installation instructions The luminaire should only be used complete with its protective shield (cover) Warranty will be void if cable assembly is tampered with. 1. Not for use on combustible surfaces. Mount only on brick, concrete or metal surface. Luminaires can become very hot. Use discretion in placement. 3 mm Do not shorten, interfere or disconnect cable from luminaire. Failure to isolate power supply before installation or maintenance may result in fire, serious injury, electric shock, death and may damage the luminaire. CAUTION Ø 20 ISOLATE LUMINAIRE FROM POWER m 82 m 284 mm DANGER 220º WARNING Installation 3 x 50 W version must be submersed before lighting. 1. Fit lamps as in re-lamping instructions (below and Fig. B) 2. Mount securing bracket using a suitable non-corrosive fastener. The body bracket may be removed by removing one dome nut and the threaded bar to ease tightening of the fastener. One 8 mm stainless steel masonry anchor is recommended for concrete mounting. transformer 3. Reattach body bracket to securing bracket if required, and then finger tighten dome nuts. 5. Do not loose joint the cable under water. Joint should either be in an approved enclosure or out of the water. 6. Ensure that the supply voltage is 12 volts before switching on. 7. Aim luminaire and tighten dome nuts. 300 mm 4. Run the cable out and connect to the source of supply (Fig A.) power outlet Figure A 2. Relamping Instructions 1. Ensure luminaire is switched off. cover 2. Loosen dome nuts, remove threaded bar and disengage body bracket. 3. Lift the luminaire from the water. stainless steel screws 4. Remove the 6 stainless steel Philips head screws that retain the cover and lift off. 5. Pull the three lamps from their respective lamp holders. 6. Push replacement lamps into luminaire, ensuring correct wattage lamps are used, and being careful not to damage the lamp’s pin. lamps 7. Inspect the seal and ensure that it is in good condition and free from dirt. 8. Fit the cover to the body and replace all 6 stainless stell Philips head screws and tighten. LS265A body 9. Replace in the water before lighting (3 x 20 W version may be safely run out of water). body bracket NOTE: Thermal protection device installed. securing bracket dome nuts Figure B www.lumascape.com.au Copyright ©2013 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773 IN0079 - 03 September 2013 Questions? Call +61 7 3286 2299 Email [email protected] www.lumascape.com.au SAFETY INSTRUCTIONS WARNING - To reduce the risk of FIRE or INJURY: 1. 2. 3. 4. 5. 6. Luminaires and transformers to be installed by licensed electrical contractors. Luminaires to be used for intended purpose only. Do not operate the luminaires with a missing or damaged parts. Use only genuine Lumascape parts to replace damaged or missing components. Refer to instructions for installation and operating requirements. Ensure installation complies with local regulations Voltage insulation test (megger) will permanently damage product and will void warranty. SAVE THESE INSTRUCTIONS. www.lumascape.com.au Copyright ©2013 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773 IN0079 - 03 September 2013