Data Bus Wiring

   EMBED


Share

Transcript

Digital Lighting Systems PROTOCOL CONTROL BUS Notes Data Cabling Information - Page 1 www.digitallighting.com RJPD-L PD Series Data Daisy-Chain / CONTROL BUS Cable The RJPD-L is a Standard RJ45 data network cable that can be used to daisy-chain the data signal from one PD to the next. It is terminated at both ends with RJ45 male connectors. The RJPD-L carries the data signal out of port J1 and into port J3 of the next PD in line. The RJPD-5 (5 foot length) is included with each PD unit. ( Longer lengths available upon request). Any standard Cat5 or better cable may be used from the market or cables may be made in the field using Cat5 cable and available crimping tools. The RJPD-L is also used to connect the PD dimmer/switch packs to the DB44 data and power hub. See Figures 2 &3 for connection details. Ordering Info: RJPD-L (L = length in feet). To Next PD Dimmer J3 Port From PD Dimmer J1 Port or DB44 Standard RJ45 CAT5 cable Figure 1: RJPD-L CONTROL BUS Cable for PD Dimmers Figure 2: Bottom View of PD Dimmer/Switch Packs Showing Connection using RJPD-L network cables. Low Voltage Ports J1 Data Only J3 Data & Power Low Voltage Ports J1 Data Only Data Only J1 Data Only J3 Data & Power Data Only Data Only Note: The CONTROL BUS between PD units uses only PAIR # 4 from the CAT5 cable for DATA transmission. Figure 3: Front view of PD Dimmer/Switch Packs Showing Connection using RJPD-L network cables to DB44. DB44 Data & Power Distribution Box PS SERIES Control Stations ON Data Only PD408 PD408 S2 S1 S2 S1 RAU-96 1 2 3 4 BOTH LED’s MUST BE ON FOR PROPER OPERATION OFF (Reset) 1 2 3 4 RJ45 JACK Digital Lighting Systems, Inc RJ45-DB44 RJPD-L connects to an RJ45 jack which plugs into the Db44 with a two-wire pigtail. See DB44 specifications for more information. 7588 NW 8th Street, Miami, Fl. 33126 Copyright Data Only Tel: 305-264-8391 or 1-877-264-8391 Data Only Fax: 305-261-6637 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A. Digital Lighting Systems PROTOCOL CONTROL BUS Notes Data Cabling Information - Page 2 www.digitallighting.com W1-W2 Jumpers ( for use in smaller systems without a DB44) Protocol systems with 3 control nodes or less (PS Series stations, DCO, DCI or RAU) do not require an external power supply transformer. Power for these components can be supplied by one of the PD Series dimmer packs. Figure 1 shows the PD's network ports with their pin assignments. Installing W1 and W2 connects the 10 VAC transformer output to the network bus via J3. The 10 VAC output is permanently connected to J1. Figure 2 shows a typical small system with one PD Dimmer supplying power to the network. Figure 3 shows a typical system with an external transformer. System accessories such as extension cables and jumper boards are available from DLS and can simplify network bus connections. TO AVOID PARALLELING THE OUTPUTS OF SEVERAL TRANSFORMERS IN A PROTOCOL SYSTEM: ( ( Do not install the jumpers in any of the PD Dimers when a DB44 panel with an external transformer is used in a system. Do not install jumpers in more than one PD Dimmer per system when no external transformer is used. Figure 1 PD Dimmers CONTROL Internal BUS Connections CAUTION USE ONLY ONE SET OF W1-W2 PER SYSTEM. W1 & W2 Jumpers Located On (LDM) Load Driver Module Control Bus Ports INSIDE PD W1 W1 Bottom View J3 Data & Power -D +D W2 DATA Only J1 Data Only J3 87654321 Figure 2 Install W1 & W2 Jumpers inside the first PD Dimmer ONLY. Use RJPD-L Network Cable Small System Powered By a PD Dimmer Module UP to 3 control nodes 4 #12 AWG Typical 2 HOT & 2 NEUT. To Distribution Panel RJ45 Jack with Power & Data Pigtail POWER & DATA POWER & DATA CABLE 2 Twisted-Pair (4-Wire) Network Cable May be Carol Cable #C3362 or Equivalent Figure 3 Typical System Powered By An External Transformer 9-10 VAC To Loads PD804 PD216 J3 J1 J3 J5 J3 J1 #1 W1-W2 DATA RJPD-L Network Cable DATA DATA RJPD-L Network Cable RJPD-L Network Cable PD408 PD804 PD216 J3 J1 J3 J5 J3 J1 #1 PSXX-PT Pigtails 2 Twisted-Pair (4-Wire) Network Cable May be Carol Cable #C3362 or Equivalent To Loads DO NOT INSTALL W1 & W2 Jumpers inside any PD Dimmer. External Power Transformer (For Stations & Control Modules) POWER & DATA CABLE RJ45PD-PT 4 #12 AWG Typical 2 HOT & 2 NEUT. To Distribution Panel PD408 POWER & DATA RJPD-L Network Cable Spliced Cables 4 #12 AWG Typical 2 HOT & 2 NEUT. To Distribution Panel To Loads RJ45-PD-PT PSXX-PT Pigtails J1 10 9 8 7 6 5 4 3 2 1 IN J3 OUT J1 N.C. N.C. N.C. N.C. N.C. N.C. N.C. 9 VAC N.C. 9 VAC N.C. 7 - DATA - DATA 8 +DATA +DATA 9 VAC 9 VAC W2 Pin 1 2 3 4 5 6 Inside PD DIMMERS PD Dimmer Transformer 9 VAC OUT +D -D RJ45 jacks Pin Assignment RJ45 JACK DB44 DATA Power & Data Distribution Panel RJ45DB44 DATA RJPD-L Network Cable DATA DATA RJPD-L Network Cable RJPD-L Network Cable DATA RJPD-L Network Cable Network Bus Branch For RAU, DCI-16, DCO-4 Or Other System Components … 7588 NW 8th Street, Miami, Fl. 33126 Copyright Tel: 305-264-8391 or 1-877-264-8391 Fax: 305-261-6637 2003 Digital Lighting Systems, All rights Reserved Specifications are subject to change without notice. Printed in U.S.A.