Preview only show first 10 pages with watermark. For full document please download

Data Center Solutions

   EMBED


Share

Transcript

Data center solutions Edition 2015/10 Protecting your investment Your partner for system solutions The HUBER+SUHNER group is a leading solutions provider serving the communication, transportation and industrial markets. Our customers appreciate that we are specialists with a strong focus on delivering practical solutions to complex problems. We offer in-house technical expertise in radio frequency, fiber optics and low frequency, providing our customers a unique combination of skills and competences.   Data center solutions At HUBER+SUHNER we leverage over 25 years of experience in creating tailored connectivity solutions which deliver «business-critical» services safely and reliably. Working together with our partners, we deliver innovative and competitive high-performance solutions to the data center market. Centered around your excellence: Our global presence and experience The HUBER+SUHNER reputation has its roots in numerous data center projects around the globe. In their successful completion, our partners and customers take advantage of our global manufacturing, assembly and distribution network, covering the Americas, the Asia Pacific region, Europe, Middle East and Africa. ● Worldwide manufacturing: Being close to our customers is a must. HUBER+SUHNER operates manufacturing plants in Poland, Brazil, China, Malaysia and Switzerland so that we can respond immediately to our customers’ needs and provide best-in-class support throughout all regions of the world. ● Worldwide assembly: HUBER+SUHNER is globally co-operating with numerous third-party fiber optic assembly shops to extend the capa­city and coverage of the HUBER+SUHNER brand. All of our assembly shops follow the same stringent processes and quality controls as our own group companies. ● Worldwide distribution: Partners can rely on HUBER+SUHNER’s worldwide sales and support network. No matter where you are in the world, you will find a HUBER+SUHNER subsidiary or distributor close to your location. 4 HUBER+SUHNER Data center Sberbank Russia 250 million private clients and 1.3 million corporate clients make Sberbank the largest credit institution in Eastern Europe. HUBER+SUHNER delivered a high-performance OM4 cabling system for high density SAN connections. Vodafone UK The UK-based Vodafone Group has one of the largest mobile footprints in the world with more than 224,000 base station sites. HUBER+SUHNER delivered a high density fiber management system connecting the network and headquarters. Federal Office of Information Technology, Systems and Telecommunications, Switzerland The Federal Office runs all the communication and IT in the Swiss administration. HUBER+SUHNER delivered customised top-of-rack SAN solutions for plug & play installations, combined with a dedicated fiber containment system. Banco do Brasil Banco do Brasil is the largest financial institution in Latin America, serving every segment of the financial market. HUBER+SUHNER designed and delivered a turnkey fiber optic solution and installation for the headquarters in Brasilia City. HUBER+SUHNER Group companies Local assembly shops HUBER+SUHNER Data center 5 Content Fiber optic solutions Fiber optic structured cabling 12 High density distribution 37 In-rack distribution 44 Zone distribution 56 SAN management 58 Fiber containment 60 Training 66 DC knowledge and best practices 71 Application overview 8 HUBER+SUHNER Data center Fiber optic structured cabling A wide range of high-performance cable systems for connecting different areas of the data center High density distribution Centralised fiber management solutions which simplify and speed up the deployment and servicing of evolving data centers In-rack distribution Compact and innovative fiber optic patch panels which reduce cable clutter and facilitate a safe and repeatable connection to switches and servers Zone distribution Robust zone distribution products that offer a demarcation point under a computer raised floor or above equipment cabinets SAN management Products for efficiently managing the fiber optic connections to high density SAN switches or core switches Fiber containment Scalable routing system that protects the bend radius and supports fiber optic cables between equipment cabinets Training Data center oriented training program aimed at developing the skills of our partners and improving the quality of service to our customers DC knowledge and best practices Supporting information to aid the design and installation process of the HUBER+SUHNER fiber optic and copper system HUBER+SUHNER Data center 9 Fiber optic solutions Fiber optic structured cabling 12 High density distribution 37 In-rack distribution 44 Zone distribution 56 SAN management 58 Fiber containment 60 HUBER+SUHNER Data center 11 MTP® 12 fiber link assemblies Characteristics • Ready to use «plug & play» cable system • Round cable construction • Small outer diameter of 3 mm for 12 fibers (3.6 mm for 24 fibers) • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 12 fiber MTP and 24 fiber MTP connectors • Packaged on installation-ready reel for lengths > 10 m • Retrofittable «push-pull» clip for high packing density (see page 55) • Low space consumption in ducts and racks • Easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Fast and safe installation straight from the reel • Highest performance singlemode and multimode MTP elite connectivity • Scalable for regular moves, adds and changes See also: Cabling accessories page 54 Fast, flexible and space efficient MTP jumper cables provide a high density link between HUBER+SUHNER optical distribution racks in the MDA and modules or ruggedised fan-outs mounted in the EDA. The compact and flexible cable design improves handling and in conjunction with bend-optimised fiber, provides a significantly reduced bend radius. This simplifies the installation process and greatly reduces the space consumption within fiber containment and equipment cabinets. MTP link assemblies longer than 10 m are supplied on a packaging reel which allows the cable to be directly installed without special equipment or re-reeling on site. Packing density without limitations In high density applications where access to the MTP connector is limited or obscured, HUBER+SUHNER recommends using a retrofittable «push-pull» clip with a built-in extension finger at the rear (see page 55). 12 HUBER+SUHNER Data center MTP® 12 fiber link assembly MTP-12 female to MTP-12 female, link assembly, elite, polarity A Length, m Item no. Singlemode Multimode OM3 Multimode OM4 1 84122726 84122765 84122761 2 85018383 84144740 84135360 3 84122727 84122766 84122762 5 84116129 84122767 84116114 7 84122728 84122768 84122763 10 84110257 84112353 84116115 15 84110252 84110254 84116116 20 84112341 84112348 84116117 25 84116130 84119589 84116118 30 84112342 84112349 84116119 35 84116131 84119586 84116120 40 84112343 84112315 84116121 45 84116132 84119582 84116122 50 84112344 84112316 84116123 55 84116133 84134484 84116125 60 84112345 84112350 84116126 65 84116134 85018141 84116127 70 84110250 84112351 84116128 75 84110251 85018331 85018242 80 84112347 84112352 84122748 85 84112346 85018333 85018243 90 84122729 84122769 84122759 95 85018229 85018335 85018244 100 84122730 84122772 84122760 For MTP patch cords, please refer to the MTP patch cord section (see page 31). HUBER+SUHNER Data center 13 MTP® 24 fiber link assembly MTP-24 female to MTP-24 female, link assembly, elite, side A top-row to side B bottom-row Length, m Item no. Multimode OM3 Multimode OM4 1 85018337 85018385 2 85018338 85018388 3 85018340 85018391 5 85018342 85018395 7 85018344 85018400 10 85018346 85017119 15 85018348 85018384 20 85018350 85018386 25 85018352 85018387 30 85018354 85018389 35 85018356 85018390 40 85018358 85021814 45 85018360 85018392 50 85018362 85018393 55 85018365 85018394 60 85018366 85018396 65 85018368 85018397 70 85018370 85018398 75 85018372 85018399 80 85018374 85018401 85 85018376 85018402 90 85018378 85018403 95 85018380 85020689 100 85018411 85018382 MTP® pulling grip The MTP pulling grip is a retrofittable housing that allows MTP based cable systems to be pulled through containment systems and vertical risers. The pulling grip can be locked together around the connector and spins freely so that no stress is applied to the connector during installation. 14 Description Item no. MTP pulling grip 85013593 HUBER+SUHNER Data center Ultralite MTP®–LC, splice–LC and LC–LC fan-outs Characteristics • Ready to use «plug & play» system • Small diameter cable for easy handling and routing • Compact furcation housing with snap-fit mounting • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types available • 12 fibers or 24 fibers per assembly • Flexible protection sleeve to aid the installation process and protect tails and connectors • Compact Ø 3 mm cable for 12 fibers for maximum space efficiency (Ø 3.6 mm for 24 fibers) • Flexible cable construction for easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Reduced cable clutter inside equipment racks • Fast identification with numbered tails • Secure fixation with slotted gland See also: Cabling accessories page 54 SAN management page 58 Reduced cable clutter and improved equipment airflow Ruggedised fan-outs provide either a flexible transition from MTP connectivity to standard LC connectors, LC connectors to LC connectors or LC connectors to open for splicing. They generally make the final connection to active equipment ports. A standard 1 m tail length can be used as a generic solution for all 19 inch horizontal blades. Ruggedised fan-outs offer a much cleaner presentation of fibers in high density switching environments and because of their compact size and construction, they reduce the possibility of blocking airflow to equipment. Short length assemblies (for direct connections to equipment) are configured with a male MTP connector because they are connected to a female backbone/horizontal cable. However, in some cases, it may be preferable to eliminate this connection and harness a longer assembly directly back to the MDA. In this case, a female MTP connector is used to correspond with the male connector positioned in the MDA. Long length assemblies reduce some of the overall flexibility but offer the user increased headroom across the complete link. The integrated mounting slot facilitates easy and robust fixation of the furcation housing either under or to one side of the equipment. HUBER+SUHNER Data center 15 MTP®–LC Side A = length Side B = 1 m Total length of ultralite = length + 1 m Splice–LC Side A = length Side B = 1 m Total length of ultralite = length + 1 m LC–LC Side B = 1 m Total length of ultralite = length + 2 m 16 HUBER+SUHNER Data center Side A = length Side B = 1 m Ultralite MTP®–LC 12 fiber (male 1 × 12 fiber) MTP-12 male elite to 6 LC-XD duplex, fan-out length 1 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 1 85019373 85022233 85019458 3 85022253 85022234 85022243 5 85022254 85022235 85022244 7 85022255 85022236 85022245 10 85022256 85022237 85022246 Ultralite MTP®–LC 12 fiber (female 1 × 12 fiber) MTP-12 female elite to 6 LC-XD, fan-out length 1 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 14 85019374 85022471 85019459 16 85019375 85022489 85019460 18 85019376 85022490 85019461 20 85019377 85022491 85019462 22 85019378 85022492 85019463 24 85019379 85022493 85019464 26 85019380 85022494 85019465 28 85019381 85022495 85019466 30 85019382 85022496 85019467 35 85019383 85022497 85019468 40 85019384 85022498 85019469 45 85019385 85022499 85019470 50 85019386 85022500 85019471 HUBER+SUHNER Data center 17 Ultralite MTP®–LC 24 fiber (male 2 × 12 fiber) 2 × MTP-12 male elite to 12 LC-XD, fan-out length 1 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 1 85019387 85022267 85019472 3 85022272 85022268 85022263 5 85022273 85022269 85022264 7 85022274 85022270 85022265 10 85022275 85022271 85022266 Ultralite MTP®–LC 24 fiber (female 2 × 12 fiber) 2 × MTP-12 female elite to 12 LC-XD, fan-out length 1 m Length, m 18 Item no. Singlemode Multimode OM3 Multimode OM4 14 85019388 85022501 85019473 16 85019389 85022502 85019474 18 85019390 85022503 85019475 20 85019391 85022504 85019476 22 85019392 85022505 85019477 24 85019393 85022506 85019478 26 85019394 85022507 85019479 28 85019395 85022508 85019480 30 85019396 85022509 85019481 35 85019397 85022510 85019482 40 85019398 85022511 85019483 45 85019399 85022512 85019484 50 85019400 85022513 85019485 HUBER+SUHNER Data center Ultralite MTP®–LC 24 fiber (female 1 × 24 fiber) MTP-24 female elite to12 LC-XD, fan-out length 1 m Length, m Item no. Multimode OM3 Multimode OM4 14 85022514 85019487 16 85022515 85019488 18 85022516 85019489 20 85022517 85019490 22 85022518 85019491 24 85022519 85019492 26 85022520 85019493 28 85022521 85019494 30 85022522 85019495 35 85022523 85019496 40 85022524 85019497 45 85022525 85019498 50 85022526 85019499 HUBER+SUHNER Data center 19 Ultralite LC–LC 12 fiber 6 LC-XD to 6 LC-XD, fan-out length 1 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 14 85019500 85022220 85019526 16 85019501 85022221 85019527 18 85019502 85022222 85019528 20 85019503 85022223 85019529 22 85019504 85022224 85019530 24 85019505 85022225 85019531 26 85019506 85022226 85019532 28 85019507 85022227 85019533 30 85019508 85022228 85019534 35 85019509 85022229 85019535 40 85019510 85022230 85019536 45 85019511 85022231 85019537 50 85019512 85022232 85019538 Ultralite LC–LC 24 fiber 12 LC-XD to 12 LC-XD, fan-out length 1 m Length, m 20 Item no. Singlemode Multimode OM3 Multimode OM4 14 85019513 85022207 85019539 16 85019514 85022208 85019540 18 85019515 85022209 85019541 20 85019516 85022210 85019542 22 85019517 85022211 85019543 24 85019518 85022212 85019544 26 85019519 85022213 85019545 28 85019520 85022214 85019547 30 85019521 85022215 85019548 35 85019522 85022216 85019549 40 85019523 85022217 85019550 45 85019524 85022218 85019551 50 85019525 85022219 85019552 HUBER+SUHNER Data center Ultralite splice–LC 12 fiber 6 LC-XD one-side, fan-out length 1 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 20 85019553 85022203 85019561 30 85019554 85022204 85019562 40 85019555 85022205 85019563 50 85019556 85022206 85019564 Ultralite splice–LC 24 fiber 12 LC-XD one-side, fan-out length 1 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 20 85019557 85022199 85019565 30 85019558 85022200 85019566 40 85019559 85022201 85019567 50 85019560 85022202 85019568 HUBER+SUHNER Data center 21 MTP® SMARTLINE optipack Characteristics • Ready to use «plug & play» system • Round sub-unitised jacketed construction • Compact and robust furcation system • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 48, 72 and 144 fibers available (12 fiber MTP) • 96, 144 and 288 fiber SMARTLINE optipacks are available on demand (24 fiber MTP) • Fan-outs are Ø 3 mm for 12 fibers and Ø 3.6 mm for 24 fibers • Robust flat-packable plastic cable reel (zero debris) • Compact cable for maximum space efficiency in ducts and racks • Flexible cable for easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Reduced cable clutter in ducts and racks • Fast identification with tail numbering • Offers the fastest possible installation of 144 and 288 fibers • Very compact system at only Ø 13.5 mm for 144 fibers and Ø 17 mm for 288 fibers Highest possible density from a cable system The MTP SMARTLINE optipack cable system from HUBER+SUHNER is purpose made for high density backbone/horizontal connections between racks or zones in the data center. The cables are constructed with either 12 fiber sub-unitised ruggedised bundles or, on demand, 24 fiber depending on the MTP connector that is applied. This construction of cable is extremely strong because each sub-unitised bundle is strain-relieved with kevlar and then jacketed. The sub-units are not only strong but extremely flexible too and this is an advantage when connecting this type of cable system directly to multi-fiber transceivers in equipment racks. The MTP SMARTLINE optipack also benefits from an integrated ripcord that can be used to lengthen the furcation length on-site. This can be a useful function depending on the type of rack and the height position of the equipment being connected. 22 HUBER+SUHNER Data center SMARTLINE optipack 48 fiber (female 4 × 12 fiber) MTP-12 female to MTP-12 female, elite, polarity A, fan-out length 2 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 14 85019050 85022035 85019130 16 85019051 85022036 85019131 18 85019052 85022037 85019132 20 85019054 85022038 85019133 22 85019055 85022039 85019134 24 85019056 85022040 85019135 26 85019057 85022041 85019136 28 85019058 85022042 85019137 30 85019059 85022043 85019138 35 85019060 85022044 85019139 40 85019061 85022045 85019141 45 85019062 85022046 85019142 50 85019063 85022047 85019143 HUBER+SUHNER Data center 23 SMARTLINE optipack 72 fiber (female 6 × 12 fiber) MTP-12 female to MTP-12 female, elite, polarity A, fan-out length 2 m Length, m Item no. Singlemode Multimode OM3 Multimode OM4 14 85019064 85022021 85019144 16 85019065 85022022 85019145 18 85019066 85022023 85019146 20 85019067 85022024 85019147 22 85019068 85022025 85019148 24 85019069 85022026 85019149 26 85019070 85022027 85019150 28 85019071 85022028 85019151 30 85019072 85022029 85019152 35 85019073 85022030 85019153 40 85019074 85022031 85019154 45 85019075 85022032 85019155 50 85019076 85022033 85019156 SMARTLINE optipack 144 fiber (female 12 × 12 fiber) MTP-12 female to MTP-12 female, elite, polarity A, fan-out length 2 m Length, m 24 Item no. Singlemode Multimode OM3 Multimode OM4 14 85019077 85022008 85019157 16 85019078 85022009 85019158 18 85019079 85022010 85019159 20 85019080 85022011 85019160 22 85019081 85022012 85019161 24 85019082 85022013 85019162 26 85019083 85022014 85019163 28 85019084 85022015 85019164 30 85019085 85022016 85019165 35 85019086 85022017 85019166 40 85019087 85022018 85019167 45 85019088 85022019 85019168 50 85019089 85022020 85019169 HUBER+SUHNER Data center MTP® MASTERLINE assemblies Characteristics • Ready to use «plug & play» system • Round micro cable construction • Compact and robust furcation system • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 24 to 144 fibers • Flexible protection sleeve to protect tails during installation • Robust flat-packable plastic cable reel (zero debris) • Compact cable for maximum space efficiency in ducts and racks • Flexible cable for easy handling and routing • Fast traceability with colour coded jacket (new OM4 heather violet) • Reduced cable clutter in ducts and racks • Fast identification with tail numbering • Fast and simple fixation of furcation housing with slot feature • Most compact system on the market (Ø 9 mm for 144 fibers) Highest possible density from a cable system The MTP MASTERLINE cable system from HUBER+SUHNER is purpose made for high density backbone/horizontal connections between racks or zones in the data center. Due to the extremely compact micro cable design, this cable system is at least 40 % more space efficient than conventional cable systems. In conjunction with bend-optimised fibers, the MTP MASTERLINE is flexible and well-suited to tight working conditions and rack spaces. In addition to high-performance fiber types, the MTP MASTERLINE system benefits from MTP elite connectivity across the range. All cable systems are supplied on robust plastic (zero debris) cable reels which not only prevent contamination of equipment but also speed up and simplify the installation process dramatically. Furcation tails are protected with a flexible pulling sleeve which aids installation and prevents any on-site damage to connections. The protection sleeve also offers long-term protection in cases where the MASTERLINE is stored under computer floors prior to use. For advice on how to install MASTERLINE systems into our HUBER+SUHNER fiber management portfolio or advice on different tail length possibilities, please contact your local HUBER+SUHNER representative. HUBER+SUHNER Data center 25 Order code MTP® MASTERLINE/Ultralite 1 26 2 3 4 – 5 6 7 – 8 9 10 11 12 1 System type side A * 9 Fanout type A 13 14 15 16 17 2 System type side B * 12 Fanout type B C MASTERLINE Compact E 1.7 mm P MT cable system (fiber sequence method A) (standard) G 2.1 mm S MT cable system (fiber sequence method C) K 3.0 mm T ATC divider (Ultralite) Ø no fanout Y MT cable system (fiber sequence Method B) 10 Fanout length A, shortest fanout length 3 Fiber type 13 Fanout length B, shortest fanout length 0 E9/125 Low Bend (G.657 A1/2) nnn fanout length, in cm 1 E9/125 (G.652-D) STD standard length 3 G50/125 -OM3 LB 4 G50/125 -OM4 LB 11 Fanout construction A 14 Fanout construction B 4 Numbers of fibers B standard fanout graduated, special length, minimum 30 cm nn numbers of fibers, always 2-digits (up to 99) E fanout equal lenght 1.0 m A=100, B=110, C=120, D=130, E=140, e.g. 144=E4 F fanout equal lenght, special length, minimum 30 cm Q fanout equal lenght standard 50 cm Ø no fanout Z special, minimum 30 cm 5 Cable type X breakout cable (Optipack12, 24 and Optibreak) 6 Cable length nnnn cable length in m, always 4-digits 7 Drum type A air ring I Reel_PL_600x400x181 J Reel_PL_600x400x331 15 Connector type A 16 Connector type B xx connector type (see connector overview) 17 Quality side A 18 Quality side B S SM standard B SM grade B / SM elite for MTP K Reel_PL_600x400x530 8 Divider S Small divider (Lite, Compact, ATC) M MM standard U Crimped divider small L V Crimped divider medium MM low loss / MM elite for MTP HUBER+SUHNER Data center 18 Connector overview Connector description Connector type Assembly class S B M L UPC APC UPC APC PC PC • • • • • • w/o connector 00 LC duplex (classic, push-pull, HD) 88/LC Duplex 89/LC APC Duplex • • LC XD 8X/LC-XD PC Duplex 8Y/LC-XD APC Duplex • • MTP® without pins, 12 fiber (female) 52 • • • MTP® with pins, 12 fiber (male) 53 • • • MTP® without pins, 24 fiber (female) 56 • • • MTP® with pins, 24 fiber (male) 57 • • • «Performance class» please see standard assembly catalogue. Drum type cable system and max. length in meters Air reel I Plastic reel small J Plastic reel medium K Plastic reel large Item no. N/A 84144609 84144608 84144607 Dimensions of reel N/A 600 × 600 × 181 mm 600 × 600 × 331 mm 600 × 600 × 530 mm Weight of reel N/A 2.6 kg 3.0 kg 4.5 kg Item no. cardboard box N/A 84144616 84144615 84144614 Dimensions cardboard box N/A 635 × 610 × 195 mm 635 × 610 × 345 mm 635 × 610 × 550 mm Cable diameter Maximum length per reel Ø 3.00 mm Ø 3.60 mm Ø 5.00 mm Ø 7.50 mm Ø 8.00 mm Ø 8.50 mm Ø 9.00 mm −100 m −60 m −50 m −50 m −50 m −50 m −50 m −900 m −800 m −400 m −150 m −150 m −130 m −120 m −1900 m −1300 m −700 m −350 m −300 m −250 m −250 m −3000 m −2000 m −1200 m −600 m −500 m −500 m −500 m < 10 kg < 20 kg < 37 kg Weight up to HUBER+SUHNER Data center 27 LC patch cords Characteristics • 1.8 mm duplex cable for LC-Classic and 2.1 mm for LC-XD uniboot • Low smoke and free of halogen (LSFH™) • Multimode OM4, OM3 and singlemode fiber • Simple polarity flipping with duplex clips • Colour coded connector shrouds (OM4 heather violet, OM3 aqua, SM yellow) • Fast patching with push-pull LC technology • Unlimited access with LC-XD • Super low-loss OM4 performance Excellence in connectivity HUBER+SUHNER patch cords are manufactured with the highest quality materials and to the strictest of manufacturing processes. Our aim is to produce patch cords that add value to our customers either by reducing the cable size, enhancing performance or improving the overall usability. In high density applications, customers can choose the innovative LC-XD connector that reduces cable bulk and speeds up the patching and re-patching process. Our unique «push-pull» LC design was the first major step in revolutionising the standard LC. With this major advancement, customers no longer need to limit their cabling designs to the restrictions of standard connectivity. LC-XD uniboot The LC-XD uniboot is designed to be used for the highest packing density. The connector has an innovative push-pull mechanism which allows efficient handling even in the smallest of spaces. Another feature is the ability of adjusting polarity without having to use any tools. LC-Classic The LC classic connector from HUBER+SUHNER is on the industry standard simplex or duplex LC which has a clip on the top face of the shroud for engaging the connector key mechanism. Unlike the XD type, the classic requires full finger access to the clip and subsequently is not optimised for environments where high packing density is required. 28 HUBER+SUHNER Data center Duplex patch cord Duplex patch cord, LC Classic to LC Classic, UPC, duplex cable 2 × 1.8 mm Length, m Item no. Singlemode Multimode OM3 Multimode OM4 1 85020915 85022112 85011859 2 85020916 85022117 85021407 3 85020917 85022118 85021408 3.5 85020918 85022119 85021409 5 85020920 85022120 85021410 6 85020921 85022121 85021411 7 85020923 85022122 85021412 10 85020924 85022123 85021413 15 85020926 85022124 85021414 20 85020927 85022125 85021415 Duplex patch cord, LC-XD to LC-XD, UPC, cable 2.1 mm Length, m Item no. Singlemode Multimode OM3 Multimode OM4 1 85016597 85022126 85011862 1.5 85023034 85025978 85019833 2 85016599 85022127 85019837 2.5 85025973 85025979 85025985 3 85016600 85022128 85019838 3.5 85020818 85022130 85021394 4 85019951 85025980 85019950 4.5 85025974 85025981 85025986 5 85016601 85022131 85019839 5.5 85025975 85025982 85025987 6 85020819 85022132 85021395 7 85020820 85022133 85021396 10 85016602 85022134 85019840 15 85020821 85022135 85021397 20 85020822 85022136 85021398 25 85025976 85025983 85025988 30 85025977 85025984 85025989 HUBER+SUHNER Data center 29 LC polarity Tx Rx Tx B A Rx B A Tx Rx Tx B A LC patch cord Type A–B/B–A Key up/Key Up Rx B A LC patch cord Type A–A/B–B Key up/Key Up • HUBER+SUHNER standard duplex polarity • HUBER+SUHNER non-standard duplex polarity • Use whenever each permanent link in a channel • Use to correct the polarity in a cabling channel where uses reverse pair positioning, so an uneven number of crosses in the cabling produces correct polarity. • Reverse pair positioning Fiber 1 – Fiber 2 Fiber 2 – Fiber 1 Fiber 3 – Fiber 4 etc. an even number of crosses is produced. The standard polarity of patch cords supplied by HUBER+SUHNER is «A–B/B–A» because although the cable is straight, the position of the fibers in the duplex connector is different at each end. When designing an array based link using 12-fiber ribbon cables, it is important to note that a pair-wise flip has to be integrated at one end of the link. However, if the link is designed using the HUBER+SUHNER cross-connect racks then it will not be necessary to use two different types of patch cords. In this instance, a A–B/B–A patch cord can be used everywhere (i.e. within the crossconnect rack and also at each end of the link). Please contact HUBER+SUHNER if you require A–A/B–B patch cords. 30 HUBER+SUHNER Data center MTP® patch cords Characteristics • Ready to use «plug & play» cable system • Round cable construction • Small outer diameter of 3 mm for 12 fibers (3.6 mm for 24 fibers) • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 12 fiber MTP and 24 fiber MTP connectors • Packaged on installed-ready reel for lengths > 10 m • Retrofittable «push-pull» clip for high packing density (see page 55) • Low space consumption in racks • Easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Highest performance singlemode and multimode MTP elite connectivity • Scalable for regular moves, adds and changes Upgrading to 40G and 100G data rates MTP patch cords are used as an upgrade path from 1G and 10G legacy systems to 40G and 100G data rates. The female to male gender configuration allows the MTP patch cord to be connected at one end to active equipment (female connector) and at the other end (male connector) to a pre-existing patch panel or transition module. By removing the pre-existing MTP to LC module and replacing it with a MTP to MTP transition module, the pre-existing backbone cable systems can be utilised. 1G and 10G systems generally use a 12 fiber MTP cable system transitioning to LC connectivity at the front of the panel. However, 40G and 100G links require an 8 fiber and 20 fiber MTP connector respectively. The MTP transition module allows 12 fiber MTP links to be transitioned to either 8 fiber of 20 fiber MTPs within the module. For lengths longer than 10 m, patch cords are packaged on an installed-ready reel. For longer length equipment to equipment links, customers should choose an MTP link assembly as shown on page 12. HUBER+SUHNER Data center 31 Patch cord MTP-12 female to MTP-12 male patch cord, elite, polarity A Length, m Item no. Multimode OM3 Multimode OM4 1 85018927 85018246 2 85018928 85018247 3 85018929 85018248 5 85018930 85018249 7 85018931 85018250 10 85018932 85018245 MTP-24 female to MTP-24 male patch cord, elite, side A/top-row to side B/bottom-row Length, m 32 Item no. Multimode OM3 Multimode OM4 1 85018933 85018406 2 85018934 85018407 3 85018935 85018408 5 85018936 85018409 7 85018937 85018410 10 85018938 85018405 HUBER+SUHNER Data center MTP® cleaning products Optipop R refillable cassette cleaners Characteristics • Suitable for MTP and LC connectors • Integrated cartridge for easy handling • Densely woven, non-static microfibers • Trigger mechanism for winding-on • Automatically seals after each clean • Easy to install replacement reels • 400+ cleanings per reel • Robust cloth does not fray or leave fibrous debris See also: MTP cleaning instructions page 76 The Optipop R hand-held cleaner utilises an integrated cartridge of woven microfiber that can be wound-on each time a connector is cleaned. The unique, densely woven microfiber cloth provides superior cleaning performance while minimising static charge. This prevents the end-face from immediately being recontaminated with airborne contaminants. Order code Description Item no. MTP cleaning, Optipop R cassette for MTP female connectors 84097538 MTP cleaning, Optipop R cassette for MTP male connectors 84097539 MTP cleaning, Optipop R cassette refill 84097551 HUBER+SUHNER Data center 33 IBC™ cleaner Characteristics • Suitable for male and female MTP connectors • 600+ cleanings per tool • Cloth made from densely woven microfibers • Cleaning cloth is washed and debris-free • Adapter tip supplied for cleaning unmated connectors • Allows «through-coupler» cleaning for rear of panel connections See also: MTP cleaning instructions page 76 The IBC brand cleaning tools are designed to clean ferrules residing inside an adapter, faceplate or bulkhead. The cleaning tools are simple to use and highly effective at removing oil and dust contaminants. Alternatively, the IBC cleaner can be used to clean unmated connectors by using a different fitting on the front of the nozzle. Order code Description Item no. IBC MTP cleaner male and female 84097537 MTP® cleaning brush Characteristics • Robust metal pin • Dust cover The MTP cleaning brush is used to remove unwanted debris from the alignment holes of an MTP female connector. Order code 34 Description Item no. MTP cleaning brush 84139205 HUBER+SUHNER Data center MTP® adapters MTP® adapter SC footprint Characteristics • SC shape footprint • Short flange snap-mount • High quality 2-piece design • Key-up, key-down type • Connector key alignment marking • Compliant with IEC standard 61754-7 and EIA/TIA-604-5 (FOCIS 5) Short flange MTP adapter with integrated fixing spring suitable for all standard SC shaped cut-outs. Description Performance Item no. MTP adapters SC footprint (13.25 × 9.75 mm), black OM3, OM4 84128644 MTP adapters SC footprint (13.25 × 9.75 mm), green SM 84089380 “ “ “ 50$;25&251(55(/,() Drawing MTP adapter SC footprint aperture HUBER+SUHNER Data center 35 MTP® ganged adapters (angled) Characteristics • Reduces bend radius of connected cables • Screw-type fixing holes • Key-up, key-down type • Connector key alignment marking • Compliant with IEC standard 61754-7 and EIA/TIA-604-5 (FOCIS 5) Ganged 1 × 2 and 1 × 4 way angled adapters suitable for reducing the bend radius of cables at each side of the adapter. Generally, this type of adapter is used in the vertical areas of equipment cabinets or at the rear of patch panels. Description Item no. MTP ganged adapters (angled), 2 ×, black 85004514 MTP ganged adapters (angled), 4 ×, black 85004517 MTP® ganged adapters (straight) Characteristics • Offers highest packing density • Screw-type fixing holes • Key-up, key-down type • Connector key alignment marking • Compliant with IEC standard 61754-7 and EIA/TIA-604-5 (FOCIS 5) Ganged adapters provide the highest packing density of connectors when space is at a premium. Generally, these types of adapters are used in patch panels close to high density switches so that backbone cables can be connected to equipment fanouts. Similarly, the 1 × 4 and 1 × 6 variants offer a narrow but high density option when adapters are positioned to the side of equipment cabinet rails. HUBER+SUHNER recommend to use the MTP push-pull clip. 36 Description Item no. MTP ganged adapters (straight), 4 ×, black 85004515 MTP ganged adapters (straight), 6 ×, black 85004516 MTP ganged adapters (straight),16 ×, black 84146192 HUBER+SUHNER Data center CDR cable distribution racks Characteristics • Only 300mm deep and completely front-accessible • Lightweight 2-post design for improved access to cables • Available as 900 mm or 1200 mm wide variants • Up to 1620 duplex LC ports per 47U 900mm cabinet • Up to 1080 MPO ports per 47U 1200mm cabinet • Integrated cable over-length management • Perforated doors to match nearby equipment cabinets • Quick release doors without tools • Mount against an unused wall or at the end of row or • Back-to-back mount on a single floor tile of 600 mm • Large apertures for all cable types, sizes and quantities • Fast installation of sub-racks from the front side • Easy mounting of sub-racks with unit position number strips • Side by side mounting with clear cable routing See also: CDR accessories page 40 Fiber trays page 42 Highest packing density for evolving data centers The CDR (Cable Distribution Rack) is a purpose-built high density fiber management rack which serves as a central cross-connect in the main distribution area of data centers. With a footprint depth of only 300 mm, the CDR is fully modular and scalable up to 1620 ports (3240 fibers) using LC connectivity and 1080 ports (25 920 fibers) using MTP connectivity . Users can benefit from a C-shaped construction where all internal sub-elements are completely installable and accessible from the front side. This important feature means that CDRs can be placed back-to-back on a single floor tile or alternatively against an unused wall for minimal space consumption. Designed to match your data center The CDR has been designed to match equipment cabinets in the datacenter and provide a seamless visual transition from passive racks to active racks. The CDR’s perforated curved doors are the same design as those used on the HUBER+SUHNER equipment cabinet range and the same quality look and feel is echoed across the complete portfolio. Configured to suit your needs The CDR is 47U high, 300 mm deep and comes in two standard width dimensions of 900 mm and 1200 mm. The 900 mm version is designed for splicing and MTP-LC furcation trays and the 1200 mm version is intended for patching only, whether it be LC or MTP cable systems. HUBER+SUHNER Data center 37 900 mm wide The 900 mm wide rack has integrated patch cord management on the right hand side and can facilitate standard fiber trays for pigtail splicing or MTP-LC furcation. Generally the 900 mm wide rack is used for 1G and 10G serial transmission where a standard LC connector interface is required. The 900 mm wide cabinet is supplied as an empty cabinet and then «tray units» can be installed on-site to accept different types of «fiber trays» depending on the required performance or connectivity type. The tray unit can be fitted to the rack on-site and has a capacity of 15 × patching trays. In a 47U high rack, a maximum of 6 × 7U tray units can be fitted giving an overall capacity of 90 × fiber trays per rack. The tray unit can accommodate MTP or LC patching trays as standard. See page 42 for fiber trays Characteristics • Rear-mounted 19 inch • Available in 2U, 3U and 7U heights • Universal adapter plate for conduit (splicing) or MTP adapters (plug & play) • Adapter plates for 3 MTP adapters (3 × 12 fibers) • 2 × fiber tray positions per 1U • Integrated patch cord mandrel • Runner mechanism for fiber trays Order code Description PU Item no. CDR 900 with integrated patch cord management and perforated doors, black (47U high, 600 mm and 300 mm door) 1 85029082 7U tray unit for connecting up to 15 MTP transition fiber trays 1 85013562 Note: Please contact your local sales representative for other configurations and types 38 Description PU Item no. 2U tray unit for connecting up to 4 MTP transition fiber trays 1 84143144 3U tray unit for connecting up to 6 MTP transition fiber trays 1 84143135 HUBER+SUHNER Data center 1200 mm wide The CDR 1200 is designed as a dedicated «patching rack» and is configured by adding a 300 mm wide cable over-length rack to the left hand side of a standard 900 mm rack. The CDR 1200 is configured so that an equal amount of cable management is provided on both sides of the rack. The 1200 mm wide rack is better suited for patching applications with standard connectivity (patch cords or fan-outs) or 40G and 100G applications where MTP connectivity is required. The patching tray unit can be fitted to the rack on-site and has a capacity of 15 × patching trays. In a 47U high rack, a maximum of 6 × 7U tray units can be fitted giving an overall capacity of 90 × patching trays per rack.The patching tray unit can accommodate MTP or LC patching trays as standard. See page 42 for patching trays Characteristics • Suitable for MTP, LC and SC • Available in 2U, 3U and 7U heights • Up to 18 × adapters per slot (0.5U) • Rear-mounted 19 inch • 2 × patch tray positions per 1U • Integrated patch cord mandrels • Runner mechanism for patch trays Order code Description PU Item no. CDR 900 with integrated patch cord management and perforated doors and side panels, black (47U high, 600 mm and 300 mm door) 1 85029082 CDR 300 with integrated patch cord management and perforated doors without side panels, black (47U high, 300 mm door) 1 85029083 7U sub-rack for patch to patch solution. Accommodates up to 15 patching trays 1 85017847 Note: Please contact your local sales representative for other configurations and types Description PU Item no. 2U sub-rack for patch to patch solution. Accommodates up to 4 patching trays 1 85015635 3U sub-rack for patch to patch solution. Accommodates up to 6 patching trays 1 85015637 HUBER+SUHNER Data center 39 CDR accessories Horizontal patch cord routing channel Characteristics • Patch cord guide for CDR 900 • Facilitates side by side rack patching • Facilitates front to back patching • Can be mounted in the upper or lower position in rack • Protective cover protects the patch cords Order code Description PU Item no. 4U routing channel for top of rack or bottom of rack mounting, silver 1 85029682 Vertical radius plate (required when routing channel is top mounted) 1 85029683 19 inch break-out plate and cover Characteristics • Full width plate for high quantity of cables • Suitable for all cable sizes and fiber counts • Provides strain relief for loose-tubes • Provides central strength member fixation • Protective cover for transition point of fibers • Suitable for top or bottom rack entry • Fast cable installation from the front side • Easy and fast installation of new cables Order code 40 Description Item no. 19 inch break-out plate for conduit fixation, black 84088572 Protective cover for 19 inch break-out Plate, black 84076533 HUBER+SUHNER Data center Conduit Characteristics • Over-sleeve conduit for cable loose-tubes • 30 mm bending radius protection • External diameter 5 mm and internal diameter 3.3 mm • Prevents loose tubes kink damage • Provides excellent strain relief Order code Description PU Item no. Cable conduit, solid wall, black (only for splice applications) 100 m 84014502 Cable conduit, slitted wall, black (only for splice applications) 100 m 85017566 Floor fixing kit Characteristics • Secures rack to concrete substrate • Takes weight load away from tile • Cable protection sleeves for threaded bar • Expanding anchors provide strong fixation • Double nut array prevents loosening during service • Large washers provide excellent support Order code Description PU Item no. Fastening kit for raised computer floors incl. anchors, threaded-rod, nuts and washers) 1 85029106 Fastening kit for solid concrete floors incl. anchor, nuts and washers 1 85091849 Additional rack mandrel kit Characteristics • Front-mountable • Lightweight aluminium • Adjustable dividers to separate cables • Anti-twist • Fast installation with front-mounted cage nut Order code Description PU Item no. Front mountable mandrel assembly incl. 2 divider plates and end cap 5 85029681 HUBER+SUHNER Data center 41 Fiber trays for splicing, MTP® transition and patching Characteristics • Sliding and pivoting design • Up to 36 × connectors per tray • All connector types possible • Horizontal support for patch cords • OM4 heather violet, OM3 aqua, SM yellow colour denotes performance • Full 30 mm bend radius limitation throughout • High protection of fibers • Clear label platforms for fast traceability • Compact design 0.5U • Flexible platform for all applications (splicing/MTP/splitters/patching) • Fast installation without tools • Easy traceability by colour and label • Side facing design for laser safety • Access to all fibers and connectors from front side See also: ODR optical distribution racks page 37 CDR accessories page 40 ODU optimised distribution unit page 44 Flexible, scalable and accessible The fiber tray is the core connectivity platform used within HUBER+SUHNER’s high density optical distribution racks (ODR). Incoming cables can either be fusion-spliced to pigtails inside the tray or alternatively pre-terminated MTP fan-outs can be factory installed for instant «plug & play» connectivity. This flexibility matches the fluid nature of data centers, offering the highest performance on the one hand and speed and flexibility on the other. The patch tray can be used for topologies that are in the process of migrating from LC connectivity to MTP connectivity. This product is therefore suitable in data centers moving away from 1G and 10G serial transmissions to 40G and 100G parallel optics. Centralised connectivity In its simplest form, each fiber tray inside the ODR represents a link to a remote area or zone in the data center. By connecting patch cords from one fiber tray to another fiber tray inside the same ODR, users can benefit from one centralised connectivity area. This is a much more structured approach to cabling than spontaneously running duplex patch cords from equipment rack to equipment rack. The fiber tray is available in eight colours so customers can allocate different areas in the network by colour which offers a uniquely high level of identification and traceability. 42 HUBER+SUHNER Data center Order code Singlemode Description Item no. 2-way MTP tray, 24 fiber MTP-12 male – standard class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A 84088536 2-way MTP tray, 24 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A 84116087 1-way MTP tray, 24 fiber MTP-24 male – standard class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A 85019034 1-way MTP tray, 24 fiber MTP-24 male – elite class,12 LC duplex ports – standard class, yellow, TIA code, polarity A 85019035 3-way MTP tray, 36 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A 85019037 Yellow tray, 12 duplex adapters, 24 pigtails, TIA colour code, heat shrink comb with protectors 1.5 × 40 mm 85019039 Order code Multimode OM3 Description Item no. 2-way MTP tray, 24 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, turquoise, TIA code, polarity A 84132645 3-way MTP tray, 36 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, turquoise, TIA code, polarity A 85011331 1-way MTP tray, 24 fiber MTP-24 male – elite class, 12 LC duplex ports – standard class, turquoise, TIA code, polarity A 85018179 Turquoise tray, 12 duplex adapters, 24 pigtails, TIA colour code, heat shrink comb with protectors 1.5 × 40 mm 85018939 Order code Multimode OM4 Description Item no. 2-way MTP tray, 24 fiber MTP-12 male – elite class, 12 LC duplex ports – low-loss class, heather violet, TIA code, polarity A 84132648 3-way MTP tray, 36 fiber MTP-12 male – elite class, 12 LC duplex ports – low-loss class, heather violet, TIA code, polarity A 85017721 1-way MTP tray, 24 fiber MTP-24 male – elite class, 12 LC duplex ports – low-loss class, heather violet, TIA code, polarity A 85017536 Heather violet tray, 12 duplex adapters, 24 pigtails, TIA colour code, heat shrink comb with protectors 1.5 × 40 mm 85019038 Order code patching tray Description Item no. Patching tray, 12 MTP adapters (transition patching) 85015429 HUBER+SUHNER Data center 43 ODU – optimised distribution unit Characteristics • Integration of LiSA fiber trays supporting splicing solution or LiSA MTP transition solution • Front-mounting allows the use in standard 19” equipment cabinets • Each height unit accommodates 2 LiSA fiber trays • A llows instant access to fiber tray and its connectivity due to runner mechanism • Integral service loop for patch cords • Horizontal and vertical patch cord guides • Integrated patch cord mandrels for bend-radius protection • Patch cord retaining ring ensures safe strain relief of patch cords exiting the unit • Lockable front door offer complete access security • Flexible mounting points at the rear make cable glanding quick and easy See also: Fiber trays page 42 Unique connectivity solution for equipment cabinets The ODU is a sub-rack which allows fiber trays to be integrated into a standard 19 inch equipment cabinet. Flexible mounting options at the rear of the ODU make cable fixation quick and easy and bend-limiting conduits give ultimate protection to the incoming fibers. Patch cords are routed to the front side of the ODU and can either be guided to the rear of the cabinet (around the vertical rail) or vertically along the front of the rail if sufficient side space is available within the cabinet. The ODU has a lockable steel door which provides security to the internal connections. This feature is particularly beneficial in collocation data centers where multiple subscribers occupy the same rack space. Order code 44 Description Item no. Optimised distribution unit, 1U, MTP version, black 84138128 Optimised distribution unit, 2U, MTP version, black 84138122 Optimised distribution unit, 3U, MTP version, black 84138119 HUBER+SUHNER Data center MTP® modules Standard type Characteristics • Robust metal construction • Capacity 12 ports • Available in all performances: singlemode and multimode (OM3 and OM4) • Produced with low-bend fiber • Polarity label and port identification affixed • Available with LC duplex, LC quad, SC and E-2000™ • Up to 36 LC duplex connectors / 72 fibers in a 1U panel • Fast tool-less installation • Compact and robust • Compatible with the fixed and sliding zone distribution panel (ZDP), vertical sub-racks and zero space brackets Standard «plug & play» modules for fast deployment The MTP module acts as a transition point inside or close to equipment racks. MTP connectors on the rear side fan out to 6 or 12 duplex connectors on the front side. This means that patch cords can be connected from the front of the module to equipment ports in the same or adjacent racks. High density type Characteristics • Robust metal construction • Capacity 12 or 18 ports • Produced with low-bend fiber • Available in all performances: singlemode and multimode (OM3 and OM4) • Recessed adapters for improved bend radius • Port identification front and top • Available with LC duplex • Up to 144 fibers per 1U HD panel • Fast tool-less installation • Compact and robust • Factory tested «plug & play» system • Compatible with vertical sub-racks, horizontal panels and zero space brackets • Recessed adapters for improved patch cord management Highest density presentation for in-rack distribution The MTP HD module is the highest density module currently available on the market. This compact unit acts as a termination point inside or close to equipment racks. MTP connectors on the rear side fan out to 12 or 18 LC duplex adapters on the front side. This means that patch cords can be connected from the front of the module to equipment ports in the same or adjacent racks. HUBER+SUHNER Data center 45 MTP® module standard type Order code Singlemode Description Item no. MTP module, black, 24 fiber 2 × MTP-12 male, standard ferrule, 12 LC duplex ports, horizontal orientation, polarity A 84087326 MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, horizontal orientation, polarity A 84116106 MTP module, black, 24 fiber 2 × MTP-12 male, standard ferrule, 6 LC quad adapters, vertical orientation, polarity A 84132165 MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 6 LC quad adapters, vertical orientation, polarity A 84132657 MTP module, black, 12 fiber 1 × MTP-12 male, elite ferrule, 6 LC duplex ports, horizontal orientation, polarity A 84088086 Order code Multimode OM3 Description Item no. MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, horizontal orientation, polarity A 84119613 MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 6 LC quad adapters, vertical orientation, polarity A 84132171 MTP module, black, 12 fiber 1 × MTP-12 male, elite ferrule, 6 LC duplex ports, horizontal orientation, polarity A 85022171 Order code Multimode OM4 Description Item no. MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, horizontal orientation, polarity A 84116108 MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 6 LC quad adapters, vertical orientation, polarity A 84132658 MTP module, black, 12 fiber 1 × MTP-12 male, elite ferrule, 6 LC duplex ports, horizontal orientation, polarity A 85018140 MTP® module high density type Order code Singlemode Description Item no. High density MTP module, black, 24 fiber 2 × MTP-12 male, standard ferrule, 12 LC duplex ports, polarity A 85014130 High density MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, polarity A 84150020 High density MTP module, black, 36 fiber 3 × MTP-12 male, standard ferrule, 18 LC duplex ports, polarity A 85014129 High density MTP module, black, 36 fiber 3 × MTP-12 male, elite ferrule, 18 LC duplex ports, polarity A 84148469 Order code Multimode OM3 Description Item no. High density MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex port, polarity A 84150022 High density MTP module, black, 36 fiber 3 × MTP-12 male, elite ferrule, 18 LC duplex ports, polarity A 84150024 Order code Multimode OM4 46 Description Item no. High density MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, polarity A 84150025 High density MTP module, black, 36 fiber 3 × MTP-12 male, elite ferrule, 18 LC duplex ports, polarity A 84148468 HUBER+SUHNER Data center Universal adapter plates Characteristics • Capacity standard version 12 × MTP/LC duplex adapters • Capacity high density version 18 × MTP/LC duplex adapters • Fast installation with snap-fixation • Port numbering for easy identification • Compatible with a wide array of sub-racks and panels • Standard UAP compatible with sliding and fixed ZDP, vertical sub-racks and zero space brackets • HDUAP compatible with HDZDP and zero space brackets See also: ZDP panels page 49 Zero space brackets page 53 High density patching in panels and sub-racks Universal adapter plates are supplied pre-loaded with adapters and can be fitted to any panel or sub-rack that accepts the highdensity or standard size MTP modules. This allows adapter plates, modules and blind plates to be mixed and matched in the same panel if desired. Adapter plates are generally used in combination with ruggedised fan-outs whereby the fan-out connects to the rear side of the plate and patch cords connect to equipment ports on the front side. Blind versions of the plate are also available in situations where panel positions are to be reserved for later use. When building an MTP link, universal adapter plates are pre-loaded with MTP adapters so that incoming link assemblies can be connected with fan-outs directly to equipment ports. In 40G and 100G applications, the pre-loaded UAP will act as a patching area whereby MTP patch cords can be connected directly to multi-fiber transceivers. All universal adapter plates have recessed adapters which not only improve the bend radius of patch cords but also provide a larger surface area for port numbering and identification. HUBER+SUHNER Data center 47 Order code universal adapter plates (standard) suitable with sliding and fixed zone distribution panel Description Performance Item no. Universal adapter plates, black, fitted with 12 SM LC duplex adapters (blue) SM 84099620 Universal adapter plates, black, fitted with 12 LC duplex adapters (turqoise) OM3 84099623 Universal adapter plates, black, fitted with 12 LC duplex adapters (heather violet) OM4 84099624 Universal adapter plates, black, fitted with 12 SC-shape MTP adapters (green) SM 85018178 Universal adapter plates, black, fitted with 12 SC-shape MTP adapters (black) OM3, OM4 85018177 Description Performance Item no. Universal adapter HD plates, black, fitted with 18 LC duplex adapters (blue) SM 85009702 Universal adapter HD plates, black, fitted with 18 LC duplex adapters (turqoise) OM3 85018189 Universal adapter HD plates, black, fitted with 18 LC duplex adapters (heather violet) OM4 85014433 Universal adapter HD plates, black, fitted with 18 SC-shape MTP adapters (green) SM 85018176 Universal adapter HD plates, black, fitted with 18 SC-shape MTP adapters (black) OM3, OM4 85014434 Order code universal adapter plates (HD) suitable with high density zone distribution panel Order code universal adapter plates (blind plates) suitable with sliding and fixed zone distribution panel Description Item no. Universal adapter plates, black 84097107 Order code universal adapter plates (blind plates) suitable with high density zone distribution panel 48 Description Item no. Universal adapter HD plates, black 84148846 HUBER+SUHNER Data center Zone distribution panel for standard modules Sliding Characteristics • Up to 3 × MTP standard modules or universal adapter plates (or blind plates) • Capacity 36 LC-duplex connections • 3 × independent sliding shelves • Cable tie-off plates at rear • Integrated cable service loop • Access and installation of modules/plates from the front side • Optional radius guides for patch cord support and bend radius protection • Parking area for MTP connectors • Pay as you grow concept See also: MTP standard modules p 45, Universal adapter plates p. 47 Park and patch functionality The ZDP sliding version allows up to three MTP standard modules or universal adapter plates (UAP) to be integrated in a 1U rack space. Three separate sliding trays within the panel allow individual modules or UAP to be installed, accessed or removed at any time without disturbing pre-connected circuits. Unused spaces can be fitted with blind plates. In addition to this, jumper cables can be pre-parked inside the panel so that modules can be added only as and when they are required. Order code Description Item no. Zone distribution panel for standard modules, sliding version, black 84088769 Note: T he standard patch cord guide supplied with this product is item no. 84093678 and can be found on page 54. However, all patch cord management brackets are interchangeable between the standard panel and high density panel. Fixed Characteristics • Up to 3 × MTP standard modules or universal adapter plates (or blind plates) • Capacity of 36 LC duplex connections • Optional cable manager for rear of panel • Access and installation of modules/plates from the front side • Optional radius guides for patch cord support and bend radius protection • Pay as you grow concept See also: MTP standard modules p 45, Universal adapter plates p. 47 Fixed modules (rear cable manager optional) The ZDP fixed version allows up to three MTP standard modules (MTM) or universal adapter plates (UAP) to be integrated in a single 1U rack space. Unused spaces can be fitted with blind plates. A pivoting cable manager can be added to the rear of the panel so that cable overlength can be managed effectively to the rear of the panel and then away to the side of the rack. Order code Description Item no. Zone distribution panel for standard modules, fixed version, black 85003955 Note: For rear cable manager please see zone distribution panels for high density modules (see page 51). HUBER+SUHNER Data center 49 Zone distribution panel for high density modules Characteristics • Offers industry leading density of 144 fibers or 24 keystone type RJ-45 jacks in 1U height space • Up to 4 × high density MTP modules or high density universal adaptor plates (or blind plates) • Up to 2 × RJ-45 modules • Mix and match fiber and copper technology in the same panel • Optional rear cable manager for cable overlength storage • Access and installation of modules/plates from the front side • Optional radius guides for patch cord support and bend radius protection • Pay as you grow concept See also: High density modules page 45 Universal adapter plates page 47 Unrivalled density in 1U of space The high density zone panel can accommodate up to four high density MTP modules (MTHDM), four high density universal adapter plates (HDUAP) or two RJ-45 modules in a single 1U rack space (unused spaces can be fitted with blind plates) and is normally positioned at the top of servers or switch cabinets. The HD panel provides unrivalled patching density and requires no complex pivoting mechanism to gain access to the connectors. This is possible because the HD module utilises HUBER+SUHNER’s revolutionary LC-XD connector which actually improves access to the connections even when the panel is in a static position. Both, fiber and copper technologies can also be mixed and matched within the same panel to ensure maximum flexibility in a 1U space. Easy access pivoting cable manager An additional cable manager can be fitted to the rear of the panel which allows excess cable to be stored and routed safely away to the sides of the equipment cabinet. The cable manager can be retrofitted if required and a pivoting function makes installation and access faster and easier. Order code Description Item no. Zone distribution panel for high density modules 84146158 Patch cord management brackets, black, for high density zone distribution panel 84146158 84146159 Note: N o patch cord guide is supplied with this panel. However, all patch cord management brackets are interchangeable between the standard panel and high density panel. 50 HUBER+SUHNER Data center Copper modules Characteristics • Robust steel construction • 12 port capacity in 3 × 4 port blocks • Compatible with keystone mounting type • Suitable for UTP and shielded cabling • Earth bonding lugs fitted to left and right on rear of the module • Port identification front and top • Compatible with the high density zone distribution panel (ZDPHD) • Up to 24 ports per 1U ZDPHD panel • Cable fixation on the back of the module • Fast, tool-less installation RJ-45 module for in-rack distribution The module fits into the high-density ZDPHD patch panel, ideally suited for equipment rack cabling distribution in RJ-45 as well as Fiber optics and accommodates up to 12 keystone mounted RJ-45 jacks per module. The compact unit acts as a termination point inside or close to equipment racks and has incoming cable fixation points on the rear of the module. Two lugs ensure the earth bonding of the entire panel, including jacks, which are themselves earthed on the front of the module. Order code Description Item no. RJ45 module, black, for up to 12 × keystone jacks 85029057 RJ45 connector cat. 6A, shielded, keystone mounting, female, 180°, silver 85030606 RJ45 connector cat. 6, unshielded, keystone mounting, female, 180°, black 85001694 Rear cable manager Characteristics • Retrofittable • Pivoting for easy access to MTP connectors • 35 mm minimum bend radius • 1U high • Robust steel and aluminium construction • Colour black Easy access pivoting cable manager An additional cable manager can be fitted to the rear of the panel which allows excess cable to be stored and routed safely away to the sides of the equipment cabinet. The cable manager can be retrofitted if required and a pivoting function makes installation and access faster and easier. Order code Description Item no. Rear cable manager, black, retrofittable, for high density zone distribution panel and zone distribution panel for standard modules (fixed version) 84146157 HUBER+SUHNER Data center 51 Zone distribution sub-rack 3U Characteristics • Up to 336 fibers per 3U (not including 1U patch cord manager) • Up to 14 × MTP standard modules or universal adapter plates (or blind plates) per chassis • Optional 1U patch cord manager • Robust steel construction • 19 inch front mounted • High density connectivity in only 4U of space (3U sub-rack plus 1U patch cord manager) • Fast installation and removal of modules • Easy access to patch cords • 30 mm bend radius protection of fibers • Tidy presentation of patch cords in rack • Complete front access to all fibers once installed • Pay as you grow concept See also: MTP standard modules page 45 High density module presentation in-rack The zone distribution sub-rack allows up to 14 × standard modules to be assembled vertically within a 4U (incl. 1U patch cord manager) high chassis. Each module has a capacity of 24 × fibers which gives a total capacity of 336 fibers using LC connectivity. The optional 1U patch cord manager guides patch cords to the right or the left side of the rack and bend limiters maintain a minimum bend radius of 30 mm. Patch cord manager (optional) Characteristics • 30 mm minimum bend radius • 1U high • Robust steel construction • 19 inch front mounted • Colour: black with blue mandrels Managing patch cords with the cable manager An additional cable manager can be fitted to the front of the Zone distribution sub-rack (3U) which guides patch cords to the right or the left side of the rack and bend limiters maintain a minimum bend radius of 30 mm. Order code 52 Description Item no. Zone distribution sub-rack 3U, black 85024932 1U patch cord manager, black 85024933 HUBER+SUHNER Data center Zero space module brackets Characteristics • 3U high for standard module • 5U high for HD module • Robust steel construction • Suitable for left or right handed rail • Open fixing slots for accurate adjustment • Module alignment guides at rear • Multiple height fixing options • Retrofittable • Available for HD and standard modules • Suitable for universal adapter plates also • Allows in-rack fiber connectivity without consuming valuable rack space • Can be added to racks where there is no available space for fiber panels • Does not require special tooling • Fits to any rack provided there is free space to the side of the rail See also: MTP standard and high density modules page 45 Universal adapter plates page 47 High density without valuable space consumption Zero space brackets are the perfect solution for bringing fiber connectivity into a rack that is already filled up with active equipment. Simply slide the bracket in front of pre-installed equipment to provide a close proximity patching field either on the right or left side of the cabinet rails. Zero space brackets are retrofittable which means that regardless of future network upgrades or technology changes, fiber connectivity can be integrated into the rack at any time. This product is not only intended as a last minute fix. Zero space brackets can play an important role in the design phase of any switch or server cabinet because they allow the rack to be fully configured with active equipment. This not only improves footprint costs but can also improve cable management due to the fact that both the patching and cable guidance are in the vertical space of the cabinet. Order code Description Item no. Zero space bracket 3U accepting 1 × standard module, black 84099852 Zero space bracket 5U accepting 2 × high density modules, black 84148923 HUBER+SUHNER Data center 53 Cabling accessories Patch cord retainer Characteristics • Guides patch cords around 19 inch vertical rails • Suitable for standard 19 inch fixing holes • Provides lateral support and strain relief for patch cords • Height 1U • Left and right mountable (40 mm side space required) • Colours grey and black • 30 mm bend radius Order code Description Item no. Patch cord retainer, black 84088889 Patch cord guide Characteristics • Guides patch cords to the side of the rack • Suitable for standard 19 inch fixing holes • Height 1U • Rapstrap tie can be added • Left and right mountable • Colours grey and black • 30 mm bend radius Order code 54 Description Item no. Patch cord guide, black 84093678 HUBER+SUHNER Data center Cabling accessories Rapstrap Characteristics • Flexible and extremely strong • Moulded plastic creates no debris • Reduces chance of cable jacket damage or fiber micro/ macro-bending • Re-useable (simply cut with scissors) • Suitable for fiber cables and patch cords • Colour black Order code Description Item no. Rapstrap cable tie, 48 pcs. 85004339 MTP® push-pull clip Characteristics • Retrofittable to all MTP connectors • Extension pin improves access to connector when densely packed • Colour black • 2-piece design Order code Description Item no. MTP push-pull clip, 50 pcs. 84140388 HUBER+SUHNER Data center 55 Zone distribution Panel Support Frame – PSF Characteristics • Robust steel construction • 19 inch compatible • Available in 2U, 3U and 4U versions • Retrofittable door kit available for 4U version • Flexible mounting options to suit any environment • Can be floor-mounted also (upside down) • Sufficient space for cable guides • Side fixings for customised brackets Zone distribution offers a high degree of flexibility The panel support frame is a zone distributor that can be mounted above racks either to a cable basket, cable ladder or containment system. High density backbone cables from the main distribution area of the data center are terminated in the PSF and act as a consolidation point in which users can easily patch to nearby server racks. This approach follows the recommendations of various standardisation bodies who recognised the need to recommend a permanent cabling system in the data center with maximum flexibility and scalability. The PSF can be strategically placed above server cabinets so regardless of regular moves, adds and changes; the connection back to the MDA remains unchanged. The mounting brackets on the PSF are fully adjustable and can be adapted to virtually any environment or fixing platform. The frame itself is based on a 19 inch footprint and allows copper or fiber optic panels to be mounted in the available space. The PSF is available in 2U, 3U and 4U height variants so customers can decide how much capacity they need based on the panel density they are using. Generally speaking, the PSF will serve a number of server racks in close proximity. Therefore, it is not necessary to offer extreme density in such a distributor. For customers who require a higher degree of security, the PSF 4U is available with a door kit which can be locked to prevent unwanted user access.Cable guides can be added to the front of the frame or alternatively fixings in the side of the frame allow customised brackets to be mounted. Order code 56 Description Item no. Panel support frame (PSF), 2U, black 85008425 Panel support frame (PSF), 3U, black 85008426 Panel support frame (PSF), 4U, black 85013642 Panel support frame (PSF), incl. door, 4U, black 85008427 Retrofittable door kit for panel support frame (PSF), 4U, black 85013643 HUBER+SUHNER Data center Underfloor Fixing Brackets – UFB Characteristics • Robust steel construction • Suitable for all 19 inch panels (copper and fiber) • Adjustable to match different sized pedestals • 2U of panel space available • Height adjustable • No tools required to fix to pedestal • Fast installation • Allows a structured cabling design according to standards such as TIA 942 • Provides localised connectivity for fast moves, adds and changes • Fast and flexible positioning anywhere in the data center • Height adjustable to clear existing infrastructure Flexible mounting under the raised floor The underfloor fixing brackets are a zone distributor that can be mounted underneath the raised computer floor of data centers. Adjustable brackets can be secured to the pedestal so that 19 inch fiber optic and copper panels can be integrated between them. This product is designed exclusively for underfloor applications and allows users to consolidate their structured cabling in strategic areas of the data center. Backbone cables connect to the back of the panels while the front patching area remains free for all of the regular patches that need to be made to nearby server racks. This zone-based approach is particularly effective in data centers where moves, adds and changes are made on a regular basis. Order code Description Item no. Underfloor fixing brackets (UFB), 1U height, black 85014178 Underfloor fixing brackets (UFB), 2U height, black 85014179 Underfloor fixing brackets (UFB), 3U height, black 85014180 HUBER+SUHNER Data center 57 High density blade organiser Characteristics • Compact 2U high construction • Brush-strip cover for cold/hot air blocking • Adjustable brackets to suit different racks • Up to 512 fiber ports per chassis • Central aperture for copper/power cables • Available with high density LC-XD connectors • Highest performance OM4 low-bend cabling • Suitable for cartridges or fan-out systems • Reduces air-flow blocking to equipment • Reduces cable clutter • Easy identification and traceability • Fast and simple blade replacement • Scalable pay as you grow cabling system • Easy handling of connectivity • Customised solutions available for different switch types See also: Ultralite fan-outs page 15 LC patch cords page 28 Innovative solutions for high density SAN switches The high density blade organiser is a 2U high chassis which can be positioned above or below a switch and allows up to 512 harnessed LC ports to be presented with minimal space consumption and air-flow disruption. The HDBO has a total of 8 × slot positions for either cartridges or fan-outs (4 left/4 right). These slots are designed to correspond with the blade positions of the switch so that pre-connectorised tails can be routed directly from the HDBO into their respective port locations. The chassis is 600 mm deep and can be installed by one person thanks to detachable brackets which can be mounted to the rear rails of the rack before the chassis is fixed. There are two types of HDBO chassis available. Customers can choose an HDBO which facilitates a closed cartridge system or alternatively an open ruggedised fan-out approach. 58 HUBER+SUHNER Data center Cartridge system The sealed cartridge system is designed with MTP adapters presented at the rear and LC or SC fan-out tails exiting through the front aperture. This approach offers a flexible link design because MTP backbone or horizontal cables can be installed before active blades or cartridges are added. Order code Description Performance Item no. High density blade organiser – cartridge system, black N/A 84127548 Cartridge for Brocade DCX switch 48-port blade, LC-XD, black OM4 85029522 Open fan-out system The fan-out approach allows individual fan-outs to be routed directly from the centralised optical distribution rack to the switch without any additional connections in the link. This approach offers less flexibility than the cartridge system but provides customers with lower link losses between the MDA and switching area. Fan-outs can be supplied with any connector type but generally the LC-XD type (push-pull with extraction finger and uniboot) is recommended because even in the highest density applications, it is significantly faster and easier to add and remove connections than any other product on the market. Order code Description Item no. High density blade organiser – open fan-out system, black 84134701 HUBER+SUHNER Data center 59 Fiber containment Characteristics • Halogen free, RoHS compliant • UV light-resistant • Flame-retardant UL94/V0 • Provides 100 % lateral support for fibers • Radius protected guiding elements • Secure and enclosed protection of fibers • Tool-less assembly • Compatible with all major brands • Resistant to electrical interference • No grounding needed • No specific tool set or skill set required • Quick and easy expansion of network • Accurate cable length calculations • Reduced operational failures and downtime • Faster traceability of circuits • Prolonged protection of fibers in disaster situations Protecting your investment The HUBER+SUHNER fiber containment solution can be installed underfloor or overhead and provides a secure and stress-free routing channel for fiber optic cabling within a data center. Curved fittings such as crosspieces, tees and elbows are specifically designed to protect fibers so that a minimum bend radius of 30 mm is maintained at all times. Components of the system include straight channels, horizontal and vertical drop-offs and non-intrusive «over-the-top exits» to equipment cabinets. Additionally, all of the necessary mounting brackets and accessories are available to provide a fast and trouble-free installation. Protective covers can also be added to individual components if a higher degree of protection is required. Lateral support and bend radius protection Unlike conventional cable baskets and ladders, the HUBER+SUHNER fiber containment solution offers lateral support along the complete fiber length. This reduces the risk of macro-bending and micro-bending of the individual cables. Easy installation The modular design of the HUBER+SUHNER fiber containment solution helps planners to meet the immediate capacity requirements of today without comprimising the expansion needs of tomorrow. Straight channels, curved fittings and interconnect components can easily be connected with standard joiners that require no special tooling or training. In addition, HUBER+SUHNER fiber containment solution is compatible with all other major brands and can easily be adapted to fit different environments and architectures. Fast installation In order to reduce installation times and simplify the complete assembly process, HUBER+SUHNER supply all duct components pre-assembled with joiners. This unique feature can reduce installation times by as much as 50 % and reduces a lot of the complexity involved in connecting straight ducts of different lengths to other components. Because a straight duct always requires at least one joiner, we assemble this in the factory so that full-length ducts can be connected in the fastest possible time. We also pre-fit the screws on the unmated side of the joiner to further improve handling and reduce installation times 60 HUBER+SUHNER Data center Main ducts and covers Order code main ducts Description Item no. Main duct (incl. 1 joiner and screws) 100 × 100 × 2000 85029745 Main duct (incl. 1 joiner and screws) 160 × 100 × 2000 85029747 Main duct (incl. 1 joiner and screws) 220 × 100 × 2000 85029748 Main duct (incl. 1 joiner and screws) 300 × 100 × 2000 85029749 Order code main ducts Description Item no. Main duct 100 × 100 × 2000 84107786 Main duct 160 × 100 × 2000 84107785 Main duct 220 × 100 × 2000 84107784 Main duct 300 × 100 × 2000 84107783 Order code covers Description Item no. Duct cover (incl. clips) 100 × 2000 85029751 Duct cover (incl. clips) 160 × 2000 85029752 Duct cover (incl. clips) 220 × 2000 85029753 Duct cover (incl. clips) 300 × 2000 85029754 Joiners and end caps Order code joiners Description Item no. Joiner (incl. screws) 100 × 100 84107835 Joiner (incl. screws) 160 × 100 84107834 Joiner (incl. screws) 220 × 100 84107833 Joiner (incl. screws) 300 × 100 84107832 Order code end caps Description Item no. End cap 100 × 100 84107847 End cap 160 × 100 84107846 End cap 220 × 100 84107845 End cap 300 × 100 84107844 HUBER+SUHNER Data center 61 Horizontal crosses and covers Order code horizontal crosses Description Item no. Horizontal cross (incl. 2 joiners and screws) 100 × 100 85029759 Horizontal cross (incl. 2 joiners and screws) 160 × 100 85029760 Horizontal cross (incl. 2 joiners and screws) 220 × 100 85029761 Horizontal cross (incl. 2 joiners and screws) 300 × 100 85029762 Order code horizontal cross covers Description Item no. Horizontal cross cover 100 84108097 Horizontal cross cover 160 84108096 Horizontal cross cover 220 84108095 Horizontal cross cover 300 84108094 Horizontal tees and covers Order code horizontal tees Description Item no. Horizontal tee (incl. 2 joiners and screws) 100 x 100 85029764 Horizontal tee (incl. 2 joiners and screws) 160 x 100 85029765 Horizontal tee (incl. 2 joiners and screws) 220 x 100 85029766 Horizontal tee (incl. 2 joiners and screws) 300 x 100 85029767 Order code horizontal tee covers 62 HUBER+SUHNER Data center Description Item no. Horizontal tee cover 100 84117259 Horizontal tee cover 160 84117258 Horizontal tee cover 220 84117257 Horizontal tee cover 300 84117256 Horizontal elbows and covers Order code horizontal elbows 90° Description Item no. Horizontal elbow 90° (incl. 1 joiner and screws) 100 × 100 85029769 Horizontal elbow 90° (incl. 1 joiner and screws) 160 × 100 85029770 Horizontal elbow 90° (incl. 1 joiner and screws) 220 × 100 85029771 Horizontal elbow 90° (incl. 1 joiner and screws) 300 × 100 85029772 Order code horizontal elbow covers 90° Description Item no. Horizontal elbow cover 90° 100 84117268 Horizontal elbow cover 90° 160 84117265 Horizontal elbow cover 90° 220 84117263 Horizontal elbow cover 90° 300 84117261 Vertical down elbows and covers Order code vertical down elbow 90° Description Item no. Vertical down elbow 90° (incl. 1 joiner and screws) 100 × 100 85029789 Vertical down elbow 90° (incl. 1 joiner and screws) 160 × 100 85029790 Vertical down elbow 90° (incl. 1 joiner and screws) 220 × 100 85029791 Vertical down elbow 90° (incl. 1 joiner and screws) 300 × 100 85029792 Order code vertical down elbow cover 90° Description Item no. Vertical down elbow cover 90° 100 84117298 Vertical down elbow cover 90° 160 84117297 Vertical down elbow cover 90° 220 84117296 Vertical down elbow cover 90° 300 84117295 HUBER+SUHNER Data center 63 Vertical up elbows and covers Order code vertical up elbow 90° Description Item no. Vertical up elbow 90° (incl. 1 joiner and screws) 100 × 100 85029794 Vertical up elbow 90° (incl. 1 joiner and screws) 160 × 100 85029795 Vertical up elbow 90° (incl. 1 joiner and screws) 220 × 100 85029796 Vertical up elbow 90° (incl. 1 joiner and screws) 300 × 100 85029797 Order code vertical up elbow cover 90° Description Item no. Vertical up elbow cover 90° 100 84117308 Vertical up elbow cover 90° 160 84117307 Vertical up elbow cover 90° 220 84117306 Vertical up elbow cover 90° 300 84117305 Trumpet outlets Order code trumpet outlets Description Item no. Trumpet outlet (incl. 1 joiner and screws) 100 × 100 85029784 Trumpet outlet (incl. 1 joiner and screws) 160 × 100 85029785 Trumpet outlet (incl. 1 joiner and screws) 220 × 100 85029786 Trumpet outlet (incl. 1 joiner and screws) 300 × 100 85029787 Reducers and covers Order code reducers Description Item no. Reducer (incl. 1 joiner and screws) 160 x 100 85029801 Reducer (incl. 1 joiner and screws) 220 x 100 85029802 Reducer (incl. 1 joiner and screws) 300 x 100 85029803 Order code reducer covers 64 HUBER+SUHNER Data center Description Item no. Reducer cover 160 84117319 Reducer cover 220 84117320 Reducer cover 300 84117322 Top outlet drop-offs and covers Order code top outlet drop-offs Description Item no. Top outlet drop-off horizontal (incl. 1 joiner and screws) 100×100 85029798 Top outlet drop-off vertical (incl. 1 joiner and screws) 100×100 85029799 Order code top outlet drop-off covers Description Item no. Top outlet drop-off cover horizontal 100 84117315 Top outlet drop-off cover vertical 100 84117316 Top outlet mounting brackets, horizontal and vertical Order code top outlet mounting brackets Description Item no. Top outlet mounting bracket, horizontal 84107849 Top outlet mounting bracket, vertical 85005492 Mounting material Order code duct fixing bolt Description Item no. Duct fixing bolt 84107837 HUBER+SUHNER Data center 65 Training Training 80 HUBER+SUHNER Data center 67 Data center certified training – D.C.C.T Characteristics • All product and application knowledge provided • Combines theoretical and hands-on content • Can be tailored to your needs • Available worldwide • Available as 1 day or 3 day extended training • Fully understand and manage the HUBER+SUHNER data center portfolio • Achieve HUBER+SUHNER certification • Become eligible for HUBER+SUHNER’s warranty package • Increase your knowledge and grow your business Increase your knowledge and grow your business The data center certified training program is aimed at installers, system integrators and re-sellers who would like to become a certified partner of HUBER+SUHNER. Participants of this training course will learn how to build a scalable and future-proofed data center using the latest components and sub-systems from the HUBER+SUHNER fiber management portfolio. Successful participants will be eligible to resell, install and warranty installations built using our data center portfolio. The training course is compiled by HUBER+SUHNER and covers the following topics: Part 1: Fiber optic basics (optional and on special request) Part 2: HUBER+SUHNER fiber management in the data center (compulsory) Part 3: Test and measurement in the data center (optional and on special request) All products and applications are covered by the data center certified training, and participants will benefit from a balanced mix of classroom and practical hands-on training. Parts 1 and 3 are based on half-day sessions, whereas part 2 is a full day of intensive training. Who should attend the training course? • Anyone seeking to become a certified data center partner of HUBER+SUHNER. • Anyone seeking to improve their general fiber and fiber management knowledge. Can the training course be adapted to particular needs? Training courses can be adapted but part 2 «Fiber management in the data center» is compulsory for those companies wishing to become eligible for the extended warranty license. Part 2 provides an in-depth view of structured cabling for data centers, the HUBER+SUHNER approach, HUBER+SUHNER products and cabling technologies. Part 1 and 3 can be chosen as optional courses and depend on the existing knowledge level and individual preferences of our partners. All training courses can be tailored to suit individual needs. Please enquire if you require bespoke training on a particular product type or application. Should you have a request for training other than that shown, please do not hesitate to contact us and we will try to facilitate your needs. 68 HUBER+SUHNER Data center How many people can attend each training course? To ensure that all participants receive the best possible training and the highest level of teacher interaction we strongly recommend to limit our classroom training to a maximum of eight trainees per training course. Where does the training take place? 3 different training locations are available as follows: • HUBER+SUHNER AG in Herisau, Switzerland • HUBER+SUHNER subsidiary offices worldwide • Partners and customer premises (not on the live network but other facility within customer premises) We strongly recommend that participants travel to our training facility at HUBER+SUHNER AG in Switzerland where they will benefit from a purpose made demonstration facility with all products and equipment at hand. This will provide the highest level of benefit for the attendees. However, we do realise that travelling to Switzerland is not always possible and for that reason we are continuously expanding our training activities and locations across the HUBER+SUHNER global network. Please do not hesitate to contact us should you require regional training in one of our HUBER+SUHNER international sites. Data center certified partner Certify your excellence As certified data center partner of HUBER+SUHNER, you can leverage our quality and reputation to facilitate your own business growth. HUBER+SUHNER Data center 69 DC knowledge and best practices Fiber containment cable capacity 72 MTP connectivity 73 MTP polarity 74 MTP cleaning instructions 76 Patch cords 78 Colour codes 79 Overview of fiber types 80 Standards 81 Glossary 82 HUBER+SUHNER Data center 71 Fiber containment cable capacity Cable capacity Below is a table showing the average capacity of the HUBER+SUHNER RaceWay system depending on different cable types and sizes. It is important to note that the higher quantity figures are based on straight ducting elements that are connected with joiners and do not represent the retrofittable top outlets. The first row however (100 mm × 45 mm), represents the useable space of a top-outlet or horizontal outlet. 40 % Expansion 60 % Capacity The cable sizes shown in the table below, reflect the various cables we use for backbone links such as MTP link assemblies, MASTERLINES and fan-outs. We have included data about patch cord sizes although we recommend that patch cords are not guided through a ducting system (only in-rack). Careful attention should be given to the capacity of the top outlets because these represent the smallest cross-section when linking two cabinets in the data center. To avoid bottle-necks, make sure that the quantity of cables per cabinet is clearly understood and planned in advance. The cable quantity table below shows an 60 % fill ratio and a 40 % expansion. We recommend that all calculations are based on these figures so as to allow for future expansion and upgrades. Cable capacity with 60 % fill-ratio Duct size Cable type and size 1.8 mm duplex 2.1 mm simplex 3 mm simplex 3.6 mm simplex 7.5 mm simplex 8.5 mm simplex 9 mm simplex 13.5 mm simplex 17 mm simplex 4500 420 604 297 218 46 36 33 12 10 10000 940 1382 653 470 101 86 72 29 21 16000 1495 2188 1049 739 163 136 118 50 32 22000 2049 3024 1445 1024 226 187 158 72 46 30000 2805 4118 1980 1394 252 252 217 92 64 Cable capacity with 40 % expansion Duct size 72 Cable type and size 1.8 mm duplex 2.1 mm simplex 3 mm simplex 3.6 mm simplex 7.5 mm simplex 8.5 mm simplex 9 mm simplex 13.5 mm simplex 17 mm simplex 4500 280 402 198 145 30 24 22 8 6 10000 626 921 435 313 67 57 48 19 14 16000 996 1458 699 492 108 90 78 33 21 22000 1366 2016 963 682 150 124 105 48 30 30000 1870 2745 1320 929 168 168 144 61 42 HUBER+SUHNER Data center MTP® connectivity Key alignment The standard MTP adaptors supplied by HUBER+SUHNER have a key-slot facing upwards on one side of the adaptor and a key-slot facing downwards on the other side of the adaptor. The purpose of this is to ensure that fibers of the same colour/ number line up with each other when mated (using polarity type A). Some competitors use a key up to key up configuration but this is based on a different polarity method than that used by HUBER+SUHNER. Key marking To ease the connection process of MTP, a white mark is placed on the connector and the adaptor which ensures that the connector key lines up with the adaptor key when mated. Gender explanation MTP connectors are available as male (with pins) and female (without pins). A male connector must always be mated to a female connector so that light transfers from one fiber to another. Failure to adhere to this rule will result in a dark connection and possible damage to the connectors. HUBER+SUHNER supply modules, fiber trays and short fan-outs (less than 5m) with a male connector and backbone cables such as link assemblies and MASTERLINES with a female connector. Gender matching requires careful planning, especially when a customised link design is implemented. In some cases (such as links to SAN switches), it may be necessary to eliminate one of the MTP connections and route long fan-outs directly from the switch back to the MDA. In this case, a fan-out with a female connector should be used because it will be connected directly with a male connector at the fiber tray. It is possible with a special shroud removal tool to convert a male connector to a female connector and vice versa. However, this cannot be carried out in a field environment. All gender re-works must be carried out in a HUBER+SUHNER factory to reduce the risk of fiber breakage or connector damage. If you have any doubt about gender matching, please contact our technical support team for guidance. MTP performance Unless otherwise requested, HUBER+SUHNER will supply all multimode OM3 and OM4 assemblies with MTP elite ferrules. This not only ensures that optimum performance is obtained across a mated pair but also allows much longer and more complex links to be constructed without exceeding the specified optical budget. Singlemode assemblies are available with standard and elite ferrules (preferred type) depending on link design and budget considerations. It is important to note that HUBER+SUHNER supply all standard and elite singlemode connectors with a green connector shroud. We do not follow the practice of some manufacturers who prefer to use yellow for elite ferrules and green for the standard ones. Optical performance Performance classes "patch field" Attenuation "reference measuring" IEC 61300-3-4, method B IEC 61300-3-6 IL max IL mean RL UPC RL APC Singlemode standard class 0.30 dB 0.20 dB > 50 dB > 85 dB 1) Multimode standard class 0.25 dB 2) n/a > 35 dB n/a Multimode low-loss class 0.15 dB n/a > 35 dB n/a 2) Performance classes "MT" 1) Singlemode standard class 0.75 dB 0.30 dB > 50 dB > 85 dB 1) Singlemode elite class 0.35 dB 0.15 dB > 50 dB > 85 dB 1) Multimode standard class 0.60 dB 2) n/a > 35 dB n/a Multimode elite class 0.35 dB 2) n/a > 35 dB n/a Measurement method 3 (OLCR) Measured with Encircled Flux (EF) 2) HUBER+SUHNER Data center 73 MTP® polarity $ % % $     .H\XS NH\GRZQDGDSWRUV $ % % $     Method A (HUBER+SUHNER standard) Method A uses key up to key down adaptors to link straight-through ribbon cables to modules/cassettes. In this respect, fiber 1 is always in the same position when looking at the array connector end-on with the key up. The polarity flip is achieved using a duplex patch cord at one end of the link. HUBER+SUHNER use and recommend method A as standard because all of the array based products are straight-through and it is only the patch cords which are flipped. Duplex clips facilitate simple on-site changes to polarity because simplex connectors can be removed from the clip and swapped over. This is a far safer approach to building an array-based network and for this reason has become the method of choice. 74 HUBER+SUHNER Data center A B B A 1 12 12 1 Key Up / Key Up adaptors B A A B 12 1 1 12 Method B Method B uses key up to key up adaptors to link straight-through ribbon cables to fiber cassettes/modules. Here, the only difference between method B cassettes and method A is the adaptor. The fiber channel is completed by flipping the second cassette and re-numbering it so that a standard A-B jumper cable can be used to connect them. This method is more complex for planners than method A because fiber numbers no longer correspond with each other (e.g . fiber 1 connects to 12, 2 to 11, 3 to 10 and so on). In addition, method B does not support singlemode installations because the array connector is angled and flipping these angles produces a mismatch. $ % % $     <ĞLJƵƉ ͬŬĞLJĚŽǁŶĂĚĂƉƚŽƌƐ $ % % $     Method C Method C uses key up to key down adaptors to link cassettes/modules using a special flipped ribbon jumper assembly. In this configuration, the ribbon cable creates the flip allowing standard straight-through patch cords to be used at each end. On longer channel links where more than one array cable is used, care must be taken to ensure that the flip remains consistent thereby making this method somewhat more complex for planners than method A. HUBER+SUHNER Data center 75 MTP® cleaning instructions IEC 62627 procedure for exposed connectors 76 1. Always inspect before cleaning. If the connector is already clean, there is no need to clean it. 2. Use a dry cleaning method. (Optipop R page 33) a. Remove connector dust cover b. Select the appropriate cleaner for male/female c. For female MTP connectors, use the cleaning brush and fluid to remove any debris from the pin holes d. Depress the green lever so that a fresh area of cleaning cloth is exposed e. Position the ferrule against the cloth so that the fibers are in contact with the cleaning material. In the case of angled connectors, the ferrule will need to be adjusted accordingly. f. Wipe the connector in the direction shown on the cassette g. Release the grip to seal off the cleaning cloth h. Let the ferrule air-dry before inspecting with a 200 × microscope i. If still contaminated repeat all steps once again j. Ensure that the connector does not touch any hard surfaces 3. If connector is still contaminated, use a wet cleaning method. a. Apply an approved cleaning fluid to a small area of lint-free cleaning cloth b. Wipe the connector over the damp area c. Wipe the connector over a dry area of cloth and allow it to dry d. Re-inspect the ferrule with a 200 × microscope HUBER+SUHNER Data center IEC 62627 procedure for in-port connectors 1. Always inspect before cleaning. If the connector is already clean, there is no need to clean it. 2. Use a dry cleaning method. (IBC cleaner page 34) a. Insert the IBC cleaner into the adaptor where the connector is mated b. Rotate the tape feeder wheel as indicated on the cleaner c. Inspect the connector with a 200 × microscope d. If still contaminated repeat steps once more 3. Use a wet cleaning method. a. Insert the cleaning bud through the adaptor and wipe the surface of the connector ferrule b. Insert the IBC cleaner into the adaptor where the connector is mated c. Allow to dry and then inspect the connector with a 200 × microscope d. If still contaminated repeat steps once more HUBER+SUHNER Data center 77 Patch cords Cable selection HUBER+SUHNER recommend that whenever possible, patch cords should only be used for in-rack connections. This simplifies Moves, Adds and Changes (MACs) and reduces the cable chaos generated by thousands of cross-network 2-fiber connections. Generally speaking, the smallest possible patch cord cable should be used for in-rack applications so that the overall cable mass can be reduced. The introduction of bend-optimised fiber across our range means that cables with a smaller outer diameter can be utilised without running the risk of performance degradation in tight spaces. Calculating patch cord lengths in HUBER+SUHNER racks The rack can either be used as a cross-connect cabinet or as an inter-connect cabinet. When used as a cross-connect solution, high density cables enter the rack from different zones of the data center and patch cords inside the rack cross-connect these different areas. The reason for this design is to reduce the time and complexity of inter-connect systems whereby patch cords are routed spontaneously from one place to another whenever a link is needed. The patch cord management area in the rack has been designed in such a way that links from any fiber tray to any fiber tray can be made with just two different patch cord lengths. This reduces complexity and allows our customers to make much better use of their stock holding. The drawing below shows the rack segmented into two halves (the upper section and the lower section). If a connection is needed between a fiber tray in the upper section of the rack to another fiber tray in the upper section of the rack, then a patch cord of 3.5 m is required. This also applies to connections made from a fiber tray in the lower section of the rack to another fiber tray in the lower section. Generally, we advise our customers to logically split the rack top to bottom so that the majority of connections are made from the top to the bottom and not from the top to top or bottom to bottom. In this case, the length of patch cord needed is 5 m. In some cases, it will be necessary to position more than one rack together so that a higher density cross-connect can be achieved. In such cases, the patch cord lengths will need to be adjusted accordingly. The figure and table hereafter show how the various segments of the racks correspond to different patch cord lengths. CDR 1 A 78 B A 3.5 m 5m CDR 2 C CDR 3 D CDR 4 E F G H 9m 8m 10 m 9m 11 m 10 m B 5 m 3.5 m 8m 5m 9m 6m 10 m 7m C 9 m 9m 3.5 m 5m 9m 8m 10 m 9m D 8m 5m 5m 3.5 m 8m 5m 9m 9m E 10 m 9m 9m 8m 3.5 m 5m 9m 8m F 9m 9m 9m 5m 5m 3.5 m 8m 5m G 11 m 10 m 10 m 9m 9m 8m 3.5 m 5m H 10 m 7m 9m 9m 8m 5m 5m 3.5 m HUBER+SUHNER Data center Colour codes Colour codes for fiber according to standard Number TIA/EIA-5981 1 blue 2 orange 3 green 4 brown 5 grey 6 natural/white 7 red 8 black 9 yellow 10 violet 11 pink 12 turqoise 1 EN 50174-1 HUBER+SUHNER Data center 79 Overview fiber types Fiber data for transmission Fiber E9/125 Wavelength [nm] Fiber G50/125 (OM3/OM4) 1310 1550 850 1300 Attenuation [dB/km] (typical) 0.35 0.21 2.30 0.55 Attenuation [dB/km] (max.) 0.40 0.25 ≤2.70 ≤1 Core Ø [µm] 9.2 ±0.4 1) 10.4 ±0.8 1) 50 ±2.5 Cladding Ø [µm] 125 ±1 125 ±2 Coating Ø [µm] 245 ±10 245 ±10 Standards • ITU G.652-D • ITU G.651 • IEC 60793-2-50 type B1.3 • IEC 60793-2-10 type A1a.2 + A1a.3 1) Mode field Ø Link lengths for standardised fiber types Wavelength Multimode G50/125 Singlemode E9/125 Fiber class according to HUBER+SUHNER F G Stand. fiber types as per ISO/IEC 11801:2002 and amend. 2 (2010) OM3 OM4 850 nm 1500 3500 Min. modal bandwith overfilled launch bandwidth [MHz*km] 1300 nm 500 500 Min. modal bandwith effective laser launch bandwith 2) [MHz*km] 850 nm 2000 4700 Channel Length (MAX)/ Channel IL (MAX) 1000BASE-SX 850 nm 1000 m/3.56 dB 3) 1100 m/3.56 dB 3) 1000BASE-LX 1300/ 1310 nm 550 m/2.35 dB 3) 550 m/2.35 dB 3) 10GBASE-SR/SW 850 nm 300 m/2.59 dB 550 m/2.59 dB 3) 10GBASE-LX4 (CWDM) 1300 nm 300 m/1.96 dB 550 m/1.96 dB 3) Application Standards 5000/4.56 dB 10GBASE-LR/LW 1270 nm 10000/6.2 dB 10GBASE-ER/EW 1550 nm 27250/10.9 dB 40GBASE-SR4 850 nm 40GBASE-LR4 (CWDM) 1310 nm 100GBASE-SR10 850 nm 100GBASE-LR4 (DWDM) 1310 nm 100GBASE-ER4 (DWDM) Attenuation TYP/MAX [dB/Km] OS2 100/1.9 dB 150/1.53 dB 10000/6.7 dB 100/1.9 dB 150/1.53 dB 10000/6.7 dB 1550 nm 40000/18.0 dB 850 nm 2.30/2.50 2.30/2.50 1300 nm 0.55/0.70 0.55/0.70 1310 nm 0.35/0.40 1550 nm 0.21/0.25 ITU G.651 ITU G.651 ITU G652-D IEC 60793-2-10 type A1a and A1a2 IEC 60793-2-10 type A1a and A1a2 IEC 60793-2-50 type B1.3 DIN VDE 0888, part 3 DIN VDE 0888, part 3 DIN VDE 0888, part 3 According to IEEE 802.3, ISO/IEC 11801-2nd edition Effective Laser Launch Bandwidth is assured using DMD as specified in IEC/PAS 60793-1-49 3) T his specification of this type of cabled optical glass was not defined when this application was ratified however channel lengths indicated are guaranteed by HUBER + SUHNER 1) 2) 80 HUBER+SUHNER Data center Standards Standards governing the design, installation, commissioning and operation of structured cabling systems, and the particular environments they operate within can be complex and confusing. There are 3 main standardisation bodies across the world and depending on where the installation takes place, they have an order of precedence. Internationally, the International Organisation for Standardisation (ISO) is the main body for producing such standards and in support of ISO the International Electrotechnical Commission (IEC), produces the standards for the relevant components. In Europe, CENELEC (European Committee for Electrotechnical Standardisation) is the overall authority for the production of standards. Various national committees also exist in many of the European countries and may take their national standards from any of the main standards bodies, or may develop their own. Typically though, normative European standards (EN) are adopted by those national standards bodies. In the Americas (including Canada), the TIA is the dominant standards body, although the structure of its standards is slightly different (and in some cases conflicting) to that of ISO and CENELEC. There tends to be more harmonisation with CENELEC and ISO standards bodies, although some of the differences with TIA are only nomenclature. HUBER+SUHNER, as a global company, supplying a globally-suitable product, references International Standards as a preference. This does not mean that relevant national standards are not complied with due to local standards always taking precedence, but this is typically most relevant in the design and installation requirements rather than components that a manufacturer may supply. These main standards are listed below: ISO/IEC 11801:2002 and A.1:2008 ISO/IEC 24764 Edition 1.0 2010-04 - Information technology – Generic cabling for customer premises - Information technology – Generic cabling systems for data centers These documents also reference component standards where applicable. ISO/IEC 14763-1:1999 + A.1:2004 ISO/IEC TR3 14763-2:1999 ISO/IEC 18010:2002 + A.1:2005 ISO/IEC 14763-3:2006 IEC 61280-4-1:2009 IEC 61935-1:2008 IEC 61935-3:2008 - Information technology – Implementation and operation of customer premises cabling – Part 1: Administration - Information technology – Implementation and operation of customer premises cabling – Part 2: Planning and installation - Information technology – Pathways and spaces for customer premises cabling - Information technology – Implementation and operation of customer premises cabling – Part 3: Testing of optical fibre cabling - Fibre-optic communication subsystem test procedures – Part 4-1: Installed cable plant – Multimode attenuation measurement - Generic cabling systems – Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801 – Part 1: Installed cabling - Testing of balanced communication cabling in accordance with ISO/IEC 11801 – Part 3: Verification and qualification in accordance with ISO/IEC 15018 HUBER+SUHNER Data center 81 Glossary 82 Balanced cable A cable construction technology used in copper structured cabling systems that generally utilises 4 pairs of twisted conductors, which are "balanced" together to provide a suitable medium for data transmission when used in conjunction with suitable connectors (typically RJ45 type). Can be produced in shielded (screened) or unscreened form. The balancing ensures consistent performance on each pair. CDR Cable distribution rack – interconnects incoming and outgoing optical fiber in a controlled way. Each fiber can be connected to every other fiber within the rack by simple patching. CENELEC European committee for electrotechnical standardization – the governing standards body within EU that covers structured cabling systems. Closely aligned to ISO standards in technical content. Data center A data center is a facility that provides space and services in order to host IT equipment. Services include power, cooling, connectivity, security and management. EDA Equipment distribution area EIA Electronic industries alliance EN European normative – a designation given to a standard written by the CENELEC organisation that has applicability throughout the EU. F/FTP A term used to describe the detailed construction of a balanced cable – stands for foil overall shield, with each pair individually foil covered. F/UTP A term used to describe the detailed construction of a balanced cable – stands for foil overall shield, with each pair unshielded. Fiber tray A splice or distribution module with telescopic hinged functionality holding fibers, splice connections and/or adaptors. The fiber tray has lateral fiber access to adaptors called side access. FOCIS Fiber optic connector intermateability standard, referenced to TIA/EIA. Generally used in North America. HDBO High density blade organiser IEC International electrotechnical commission – the standards body that typically provides the standards that cover component performance, often in conjunction with ISO. IEEE Institute of electrical and electronics engineers – the body that produces many of the applications standards, particularly those of the ethernet type. ISO International organization for standardization LC Lucent connector, type of optical fiber connector LC-Classic LC connector according industry standard type. A conventional key and clip mechanism is used. LFF Large form factor (connector) – such as SC, ST type. Link losses The sum of all losses in a fiber cabling system and includes fiber attenuation factor, mated connector pairs and splices but excludes equipment cord cable attenuation and the equipment connection itself. LSFH™ An acronym used to describe the characteristics of the standard HUBER+SUHNER cable jacket material – which stands for "low smoke and free of halogen". HUBER+SUHNER Data center MAC Moves, adds and changes – the sometimes complex process by which users, equipment and services are altered and reprovisioned. MDA Main distribution area – the area that houses the distributor used to make connections between the main distribution cabling sub-system, network access cabling sub-system and cabling subsystems (as specified in ISO/IEC 11801) and active equipment. MASTERLINE The MTP MASTERLINE cable system from HUBER+SUHNER is purpose made for high density backbone/horizontal connections between racks or zones in the data center. MCM Multi-circuit management – a type of splice tray design that allows multiple optical circuits (often 24 or 48 fibers) to be managed in a single splice tray. MM Multi mode (or multimode) – an optical technology description which is generally used in short distance communications (sub 2 km) but basically describes the method by which the light passes along the glass - by multiple "mode" or paths. Requires less precision of components to ensure alignment of the core (50 - 62.5 microns) but needs a more complex manufacturing method for the glass. MTP Mechanical transfer push-pull - an enhanced version of the MPO connector offering higher optical perfomance, repeatability and reliability. MTP link assemblies Cable assemblies using 12 fiber cable with MTP connectors terminated at either end. MPO Multi-fiber push-on – an optical connector, standardised under IEC 61754-7:2008 (multimode only) which provides an interface for up to 72 fibers in a single unit, utilising individual rows of 12 fibers in a polymeric ferrule. NGR New generation rack ODU Optimised distribution unit – sub-rack that houses fiber trays and can be front mounted to any 19 inch rack. OM1 Optical multimode class 1 – typically is only now available in the market with 62.5 µm diameter core and is the lowest bandwidth commercially available. No longer recognised by standards as suitable for installation in a DC. OM2 Optical multimode class 2 – typically is only now available in the market with 50 µm diameter core and is considered the minimum bandwidth suitable for LAN applications, but does offer extremely limited application support for any application above 1GB/s. No longer recognised by Standards as suitable for installation in a DC. OM3 Optical multimode class 3 – only available in the market with 50 µm diameter core and is now considered the minimum bandwidth suitable for LAN and Data Center applications. It is the first "laser optimised" multimode optical fiber and was developed to provide increaded bandwidth (and hence reach) for VCSEL 850 nm opto-electronnic devices, such as used in 10GBASE-SR. OM4 Optical multimode class 4 – only available in the market with 50 µm diameter core and is now considered the most future-proofed class, suitable for LAN and Data Center applications. It is the second "laser optimised" multimode optical fiber, offering more than double the bandwidth of OM3 at the critical 850 nm wavelength. OS1 Optical singlemode class 1 – this is the de-facto standard singlemode fiber and has been utilised for many years where applications need to be delivered over extended distances (i.e. >1 km). OS2 Optical singlemode class 2 þ this is often described as "low water peak" singlemode, and offers both lower attenuation and a flatter attenuation curve in the wavelengths of 1310 and 1550 nm, allowing wave division multiplexing-based applications to utilise the previously unavailable zone found between those wavelengths. Patch cord Ruggedised cable assembly with connectors on both ends used to cross-connect individual links. Can also be used to connect links to transceivers and when added to a link, create a channel. HUBER+SUHNER Data center 83 84 Pigtail Cable assembly with connector on one end; typically cable Ø 0.9 mm RJ45 Registered jack, type 45 – a term generally used to describe a 8P (8 position), 8C (8 contact) RJ-style connector, and can be gendered male of female. Typically supplied in ethernet transceivers and then used in the structurd cabling system within the LAN and data center. Cabling systems using this connector are typically limited to a channel length of 100 m with a maximum of 4 connections at 500 MHz and category 6A/class EA channels. SAN Storage area network: A network that is designed specifically for the needs of storage devices. Often a separate cabling system is used due to the frequent use of the FC (fiberchannel) transmission protocol and specific FC transceivers. SC Subscriber connector, a type of optical fiber connector SCM Single-circuit management. Generally refers to a cassette that houses only 1 or 2 fibers. SFF Small-form-factor connector with a Ø 1.25 mm ferrule, this size allows a higher packing density. Available types: LX.5, LC, MU etc. S/FTP A term used to describe the detailed construction of a balanced cable – stands for braid overall shield, with each pair individually foil covered. Side access Adaptors and connectors are side facing SM Single mode (or singlemode) – an optical technology description which is generally used in long distance communications but basically describes the method by which the light passes along the glass – by a single "mode" or path. Requires a greater precision of components to ensure alignment of the very small core (8 to 10 microns). Splice Permanent joint between 2 optical fibers, created by fusion (heat), clamping or gluing. TIA Telecoms industry association – U.S standards creation body for structured cabling systems, also generally adopted by canadian standards asssociation. Transition assembly An assembly of cabled optical fibers and connectors, with an array connector at one end and simplex or duplex connectors at the other end. Typically used within a plug & play cassette or to make the final connections into a switch blade. U/FTP A term used to describe the detailed construction of a balanced cable – stands for no overall shield, with each pair individually foil covered. U/UTP A term used to describe the detailed construction of a balanced cable – stands for no overall shield, with each pair unshielded. More commonly referred to as "UTP". ZDA Zone distribution area ZDP Zone distribution panel HUBER+SUHNER Data center Enter a world full of benefits: datacenter.hubersuhner.com On our data center web platform, you will find more detailed and up-to-date facts on our solutions, including additional examples of projects, documentations, videos and more. HUBER+SUHNER Data center 85 Further catalogues All our catalogues are updated regularly. They are available in electronic format and can be accessed from our main HUBER+SUHNER homepage. Simply go to the «Downloads» section and select «Fiber Optics» and «Catalogues» to filter down your search. http://hubersuhner.com/en/Service-Contact/Downloads HUBER+SUHNER is certified according to ISO 9001, EN(AS)9100, ISO 14001, ISO/TS 16949 and IRIS. Waiver Fact and figures herein are for information only and do not represent any warranty of any kind. 84099895/10.2015 HUBER+SUHNER AG Fiber Optics Division Degersheimerstrasse 14 9100 Herisau Switzerland Tel. +41 71 353 4111 Fax +41 71 353 4444 hubersuhner.com