Data center solutions Edition 2015/10
Protecting your investment
Your partner for system solutions The HUBER+SUHNER group is a leading solutions provider serving the communication, transportation and industrial markets. Our customers appreciate that we are specialists with a strong focus on delivering practical solutions to complex problems. We offer in-house technical expertise in radio frequency, fiber optics and low frequency, providing our customers a unique combination of skills and competences. Data center solutions At HUBER+SUHNER we leverage over 25 years of experience in creating tailored connectivity solutions which deliver «business-critical» services safely and reliably. Working together with our partners, we deliver innovative and competitive high-performance solutions to the data center market.
Centered around your excellence: Our global presence and experience The HUBER+SUHNER reputation has its roots in numerous data center projects around the globe. In their successful completion, our partners and customers take advantage of our global manufacturing, assembly and distribution network, covering the Americas, the Asia Pacific region, Europe, Middle East and Africa. ● Worldwide
manufacturing: Being close to our customers is a must. HUBER+SUHNER operates manufacturing plants in Poland, Brazil, China, Malaysia and Switzerland so that we can respond immediately to our customers’ needs and provide best-in-class support throughout all regions of the world.
● Worldwide
assembly: HUBER+SUHNER is globally co-operating with numerous third-party fiber optic assembly shops to extend the capacity and coverage of the HUBER+SUHNER brand. All of our assembly shops follow the same stringent processes and quality controls as our own group companies.
● Worldwide
distribution: Partners can rely on HUBER+SUHNER’s worldwide sales and support network. No matter where you are in the world, you will find a HUBER+SUHNER subsidiary or distributor close to your location.
4
HUBER+SUHNER Data center
Sberbank Russia 250 million private clients and 1.3 million corporate clients make Sberbank the largest credit institution in Eastern Europe. HUBER+SUHNER delivered a high-performance OM4 cabling system for high density SAN connections.
Vodafone UK The UK-based Vodafone Group has one of the largest mobile footprints in the world with more than 224,000 base station sites. HUBER+SUHNER delivered a high density fiber management system connecting the network and headquarters.
Federal Office of Information Technology, Systems and Telecommunications, Switzerland The Federal Office runs all the communication and IT in the Swiss administration. HUBER+SUHNER delivered customised top-of-rack SAN solutions for plug & play installations, combined with a dedicated fiber containment system.
Banco do Brasil Banco do Brasil is the largest financial institution in Latin America, serving every segment of the financial market. HUBER+SUHNER designed and delivered a turnkey fiber optic solution and installation for the headquarters in Brasilia City.
HUBER+SUHNER Group companies Local assembly shops
HUBER+SUHNER Data center
5
Content
Fiber optic solutions
Fiber optic structured cabling
12
High density distribution
37
In-rack distribution
44
Zone distribution
56
SAN management
58
Fiber containment
60
Training 66
DC knowledge and best practices
71
Application overview
8
HUBER+SUHNER Data center
Fiber optic structured cabling A wide range of high-performance cable systems for connecting different areas of the data center High density distribution Centralised fiber management solutions which simplify and speed up the deployment and servicing of evolving data centers In-rack distribution Compact and innovative fiber optic patch panels which reduce cable clutter and facilitate a safe and repeatable connection to switches and servers Zone distribution Robust zone distribution products that offer a demarcation point under a computer raised floor or above equipment cabinets SAN management Products for efficiently managing the fiber optic connections to high density SAN switches or core switches Fiber containment Scalable routing system that protects the bend radius and supports fiber optic cables between equipment cabinets
Training Data center oriented training program aimed at developing the skills of our partners and improving the quality of service to our customers
DC knowledge and best practices Supporting information to aid the design and installation process of the HUBER+SUHNER fiber optic and copper system
HUBER+SUHNER Data center
9
Fiber optic solutions
Fiber optic structured cabling
12
High density distribution
37
In-rack distribution
44
Zone distribution
56
SAN management
58
Fiber containment
60
HUBER+SUHNER Data center
11
MTP® 12 fiber link assemblies Characteristics • Ready to use «plug & play» cable system • Round cable construction • Small outer diameter of 3 mm for 12 fibers (3.6 mm for 24 fibers) • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 12 fiber MTP and 24 fiber MTP connectors • Packaged on installation-ready reel for lengths > 10 m • Retrofittable «push-pull» clip for high packing density (see page 55) • Low space consumption in ducts and racks • Easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Fast and safe installation straight from the reel • Highest performance singlemode and multimode MTP elite connectivity • Scalable for regular moves, adds and changes See also: Cabling accessories page 54
Fast, flexible and space efficient MTP jumper cables provide a high density link between HUBER+SUHNER optical distribution racks in the MDA and modules or ruggedised fan-outs mounted in the EDA. The compact and flexible cable design improves handling and in conjunction with bend-optimised fiber, provides a significantly reduced bend radius. This simplifies the installation process and greatly reduces the space consumption within fiber containment and equipment cabinets. MTP link assemblies longer than 10 m are supplied on a packaging reel which allows the cable to be directly installed without special equipment or re-reeling on site. Packing density without limitations In high density applications where access to the MTP connector is limited or obscured, HUBER+SUHNER recommends using a retrofittable «push-pull» clip with a built-in extension finger at the rear (see page 55).
12
HUBER+SUHNER Data center
MTP® 12 fiber link assembly MTP-12 female to MTP-12 female, link assembly, elite, polarity A
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
1
84122726
84122765
84122761
2
85018383
84144740
84135360
3
84122727
84122766
84122762
5
84116129
84122767
84116114
7
84122728
84122768
84122763
10
84110257
84112353
84116115
15
84110252
84110254
84116116
20
84112341
84112348
84116117
25
84116130
84119589
84116118
30
84112342
84112349
84116119
35
84116131
84119586
84116120
40
84112343
84112315
84116121
45
84116132
84119582
84116122
50
84112344
84112316
84116123
55
84116133
84134484
84116125
60
84112345
84112350
84116126
65
84116134
85018141
84116127
70
84110250
84112351
84116128
75
84110251
85018331
85018242
80
84112347
84112352
84122748
85
84112346
85018333
85018243
90
84122729
84122769
84122759
95
85018229
85018335
85018244
100
84122730
84122772
84122760
For MTP patch cords, please refer to the MTP patch cord section (see page 31).
HUBER+SUHNER Data center
13
MTP® 24 fiber link assembly MTP-24 female to MTP-24 female, link assembly, elite, side A top-row to side B bottom-row
Length, m
Item no. Multimode OM3
Multimode OM4
1
85018337
85018385
2
85018338
85018388
3
85018340
85018391
5
85018342
85018395
7
85018344
85018400
10
85018346
85017119
15
85018348
85018384
20
85018350
85018386
25
85018352
85018387
30
85018354
85018389
35
85018356
85018390
40
85018358
85021814
45
85018360
85018392
50
85018362
85018393
55
85018365
85018394
60
85018366
85018396
65
85018368
85018397
70
85018370
85018398
75
85018372
85018399
80
85018374
85018401
85
85018376
85018402
90
85018378
85018403
95
85018380
85020689
100
85018411
85018382
MTP® pulling grip The MTP pulling grip is a retrofittable housing that allows MTP based cable systems to be pulled through containment systems and vertical risers. The pulling grip can be locked together around the connector and spins freely so that no stress is applied to the connector during installation.
14
Description
Item no.
MTP pulling grip
85013593
HUBER+SUHNER Data center
Ultralite MTP®–LC, splice–LC and LC–LC fan-outs Characteristics • Ready to use «plug & play» system • Small diameter cable for easy handling and routing • Compact furcation housing with snap-fit mounting • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types available • 12 fibers or 24 fibers per assembly • Flexible protection sleeve to aid the installation process and protect tails and connectors • Compact Ø 3 mm cable for 12 fibers for maximum space efficiency (Ø 3.6 mm for 24 fibers) • Flexible cable construction for easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Reduced cable clutter inside equipment racks • Fast identification with numbered tails • Secure fixation with slotted gland See also: Cabling accessories page 54 SAN management page 58 Reduced cable clutter and improved equipment airflow Ruggedised fan-outs provide either a flexible transition from MTP connectivity to standard LC connectors, LC connectors to LC connectors or LC connectors to open for splicing. They generally make the final connection to active equipment ports. A standard 1 m tail length can be used as a generic solution for all 19 inch horizontal blades. Ruggedised fan-outs offer a much cleaner presentation of fibers in high density switching environments and because of their compact size and construction, they reduce the possibility of blocking airflow to equipment. Short length assemblies (for direct connections to equipment) are configured with a male MTP connector because they are connected to a female backbone/horizontal cable. However, in some cases, it may be preferable to eliminate this connection and harness a longer assembly directly back to the MDA. In this case, a female MTP connector is used to correspond with the male connector positioned in the MDA. Long length assemblies reduce some of the overall flexibility but offer the user increased headroom across the complete link. The integrated mounting slot facilitates easy and robust fixation of the furcation housing either under or to one side of the equipment.
HUBER+SUHNER Data center
15
MTP®–LC Side A = length
Side B = 1 m
Total length of ultralite = length + 1 m
Splice–LC Side A = length
Side B = 1 m
Total length of ultralite = length + 1 m
LC–LC Side B = 1 m
Total length of ultralite = length + 2 m
16
HUBER+SUHNER Data center
Side A = length
Side B = 1 m
Ultralite MTP®–LC 12 fiber (male 1 × 12 fiber) MTP-12 male elite to 6 LC-XD duplex, fan-out length 1 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
1
85019373
85022233
85019458
3
85022253
85022234
85022243
5
85022254
85022235
85022244
7
85022255
85022236
85022245
10
85022256
85022237
85022246
Ultralite MTP®–LC 12 fiber (female 1 × 12 fiber) MTP-12 female elite to 6 LC-XD, fan-out length 1 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
14
85019374
85022471
85019459
16
85019375
85022489
85019460
18
85019376
85022490
85019461
20
85019377
85022491
85019462
22
85019378
85022492
85019463
24
85019379
85022493
85019464
26
85019380
85022494
85019465
28
85019381
85022495
85019466
30
85019382
85022496
85019467
35
85019383
85022497
85019468
40
85019384
85022498
85019469
45
85019385
85022499
85019470
50
85019386
85022500
85019471
HUBER+SUHNER Data center
17
Ultralite MTP®–LC 24 fiber (male 2 × 12 fiber) 2 × MTP-12 male elite to 12 LC-XD, fan-out length 1 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
1
85019387
85022267
85019472
3
85022272
85022268
85022263
5
85022273
85022269
85022264
7
85022274
85022270
85022265
10
85022275
85022271
85022266
Ultralite MTP®–LC 24 fiber (female 2 × 12 fiber) 2 × MTP-12 female elite to 12 LC-XD, fan-out length 1 m
Length, m
18
Item no. Singlemode
Multimode OM3
Multimode OM4
14
85019388
85022501
85019473
16
85019389
85022502
85019474
18
85019390
85022503
85019475
20
85019391
85022504
85019476
22
85019392
85022505
85019477
24
85019393
85022506
85019478
26
85019394
85022507
85019479
28
85019395
85022508
85019480
30
85019396
85022509
85019481
35
85019397
85022510
85019482
40
85019398
85022511
85019483
45
85019399
85022512
85019484
50
85019400
85022513
85019485
HUBER+SUHNER Data center
Ultralite MTP®–LC 24 fiber (female 1 × 24 fiber) MTP-24 female elite to12 LC-XD, fan-out length 1 m
Length, m
Item no. Multimode OM3
Multimode OM4
14
85022514
85019487
16
85022515
85019488
18
85022516
85019489
20
85022517
85019490
22
85022518
85019491
24
85022519
85019492
26
85022520
85019493
28
85022521
85019494
30
85022522
85019495
35
85022523
85019496
40
85022524
85019497
45
85022525
85019498
50
85022526
85019499
HUBER+SUHNER Data center
19
Ultralite LC–LC 12 fiber 6 LC-XD to 6 LC-XD, fan-out length 1 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
14
85019500
85022220
85019526
16
85019501
85022221
85019527
18
85019502
85022222
85019528
20
85019503
85022223
85019529
22
85019504
85022224
85019530
24
85019505
85022225
85019531
26
85019506
85022226
85019532
28
85019507
85022227
85019533
30
85019508
85022228
85019534
35
85019509
85022229
85019535
40
85019510
85022230
85019536
45
85019511
85022231
85019537
50
85019512
85022232
85019538
Ultralite LC–LC 24 fiber 12 LC-XD to 12 LC-XD, fan-out length 1 m
Length, m
20
Item no. Singlemode
Multimode OM3
Multimode OM4
14
85019513
85022207
85019539
16
85019514
85022208
85019540
18
85019515
85022209
85019541
20
85019516
85022210
85019542
22
85019517
85022211
85019543
24
85019518
85022212
85019544
26
85019519
85022213
85019545
28
85019520
85022214
85019547
30
85019521
85022215
85019548
35
85019522
85022216
85019549
40
85019523
85022217
85019550
45
85019524
85022218
85019551
50
85019525
85022219
85019552
HUBER+SUHNER Data center
Ultralite splice–LC 12 fiber 6 LC-XD one-side, fan-out length 1 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
20
85019553
85022203
85019561
30
85019554
85022204
85019562
40
85019555
85022205
85019563
50
85019556
85022206
85019564
Ultralite splice–LC 24 fiber 12 LC-XD one-side, fan-out length 1 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
20
85019557
85022199
85019565
30
85019558
85022200
85019566
40
85019559
85022201
85019567
50
85019560
85022202
85019568
HUBER+SUHNER Data center
21
MTP® SMARTLINE optipack Characteristics • Ready to use «plug & play» system • Round sub-unitised jacketed construction • Compact and robust furcation system • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 48, 72 and 144 fibers available (12 fiber MTP) • 96, 144 and 288 fiber SMARTLINE optipacks are available on demand (24 fiber MTP) • Fan-outs are Ø 3 mm for 12 fibers and Ø 3.6 mm for 24 fibers • Robust flat-packable plastic cable reel (zero debris) • Compact cable for maximum space efficiency in ducts and racks • Flexible cable for easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Reduced cable clutter in ducts and racks • Fast identification with tail numbering • Offers the fastest possible installation of 144 and 288 fibers • Very compact system at only Ø 13.5 mm for 144 fibers and Ø 17 mm for 288 fibers
Highest possible density from a cable system The MTP SMARTLINE optipack cable system from HUBER+SUHNER is purpose made for high density backbone/horizontal connections between racks or zones in the data center. The cables are constructed with either 12 fiber sub-unitised ruggedised bundles or, on demand, 24 fiber depending on the MTP connector that is applied. This construction of cable is extremely strong because each sub-unitised bundle is strain-relieved with kevlar and then jacketed. The sub-units are not only strong but extremely flexible too and this is an advantage when connecting this type of cable system directly to multi-fiber transceivers in equipment racks. The MTP SMARTLINE optipack also benefits from an integrated ripcord that can be used to lengthen the furcation length on-site. This can be a useful function depending on the type of rack and the height position of the equipment being connected.
22
HUBER+SUHNER Data center
SMARTLINE optipack 48 fiber (female 4 × 12 fiber) MTP-12 female to MTP-12 female, elite, polarity A, fan-out length 2 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
14
85019050
85022035
85019130
16
85019051
85022036
85019131
18
85019052
85022037
85019132
20
85019054
85022038
85019133
22
85019055
85022039
85019134
24
85019056
85022040
85019135
26
85019057
85022041
85019136
28
85019058
85022042
85019137
30
85019059
85022043
85019138
35
85019060
85022044
85019139
40
85019061
85022045
85019141
45
85019062
85022046
85019142
50
85019063
85022047
85019143
HUBER+SUHNER Data center
23
SMARTLINE optipack 72 fiber (female 6 × 12 fiber) MTP-12 female to MTP-12 female, elite, polarity A, fan-out length 2 m
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
14
85019064
85022021
85019144
16
85019065
85022022
85019145
18
85019066
85022023
85019146
20
85019067
85022024
85019147
22
85019068
85022025
85019148
24
85019069
85022026
85019149
26
85019070
85022027
85019150
28
85019071
85022028
85019151
30
85019072
85022029
85019152
35
85019073
85022030
85019153
40
85019074
85022031
85019154
45
85019075
85022032
85019155
50
85019076
85022033
85019156
SMARTLINE optipack 144 fiber (female 12 × 12 fiber) MTP-12 female to MTP-12 female, elite, polarity A, fan-out length 2 m
Length, m
24
Item no. Singlemode
Multimode OM3
Multimode OM4
14
85019077
85022008
85019157
16
85019078
85022009
85019158
18
85019079
85022010
85019159
20
85019080
85022011
85019160
22
85019081
85022012
85019161
24
85019082
85022013
85019162
26
85019083
85022014
85019163
28
85019084
85022015
85019164
30
85019085
85022016
85019165
35
85019086
85022017
85019166
40
85019087
85022018
85019167
45
85019088
85022019
85019168
50
85019089
85022020
85019169
HUBER+SUHNER Data center
MTP® MASTERLINE assemblies Characteristics • Ready to use «plug & play» system • Round micro cable construction • Compact and robust furcation system • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 24 to 144 fibers • Flexible protection sleeve to protect tails during installation • Robust flat-packable plastic cable reel (zero debris) • Compact cable for maximum space efficiency in ducts and racks • Flexible cable for easy handling and routing • Fast traceability with colour coded jacket (new OM4 heather violet) • Reduced cable clutter in ducts and racks • Fast identification with tail numbering • Fast and simple fixation of furcation housing with slot feature • Most compact system on the market (Ø 9 mm for 144 fibers)
Highest possible density from a cable system The MTP MASTERLINE cable system from HUBER+SUHNER is purpose made for high density backbone/horizontal connections between racks or zones in the data center. Due to the extremely compact micro cable design, this cable system is at least 40 % more space efficient than conventional cable systems. In conjunction with bend-optimised fibers, the MTP MASTERLINE is flexible and well-suited to tight working conditions and rack spaces. In addition to high-performance fiber types, the MTP MASTERLINE system benefits from MTP elite connectivity across the range. All cable systems are supplied on robust plastic (zero debris) cable reels which not only prevent contamination of equipment but also speed up and simplify the installation process dramatically. Furcation tails are protected with a flexible pulling sleeve which aids installation and prevents any on-site damage to connections. The protection sleeve also offers long-term protection in cases where the MASTERLINE is stored under computer floors prior to use. For advice on how to install MASTERLINE systems into our HUBER+SUHNER fiber management portfolio or advice on different tail length possibilities, please contact your local HUBER+SUHNER representative.
HUBER+SUHNER Data center
25
Order code MTP® MASTERLINE/Ultralite 1
26
2
3
4
–
5
6
7
–
8
9
10
11
12
1
System type side A *
9
Fanout type A
13
14
15
16
17
2
System type side B *
12
Fanout type B
C
MASTERLINE Compact
E
1.7 mm
P
MT cable system (fiber sequence method A) (standard)
G
2.1 mm
S
MT cable system (fiber sequence method C)
K
3.0 mm
T
ATC divider (Ultralite)
Ø
no fanout
Y
MT cable system (fiber sequence Method B)
10
Fanout length A, shortest fanout length
3
Fiber type
13
Fanout length B, shortest fanout length
0
E9/125 Low Bend (G.657 A1/2)
nnn
fanout length, in cm
1
E9/125 (G.652-D)
STD
standard length
3
G50/125 -OM3 LB
4
G50/125 -OM4 LB
11
Fanout construction A
14
Fanout construction B
4
Numbers of fibers
B
standard fanout graduated, special length, minimum 30 cm
nn
numbers of fibers, always 2-digits (up to 99)
E
fanout equal lenght 1.0 m
A=100, B=110, C=120, D=130, E=140, e.g. 144=E4
F
fanout equal lenght, special length, minimum 30 cm
Q
fanout equal lenght standard 50 cm
Ø
no fanout
Z
special, minimum 30 cm
5
Cable type
X
breakout cable (Optipack12, 24 and Optibreak)
6
Cable length
nnnn
cable length in m, always 4-digits
7
Drum type
A
air ring
I
Reel_PL_600x400x181
J
Reel_PL_600x400x331
15
Connector type A
16
Connector type B
xx
connector type (see connector overview)
17
Quality side A
18
Quality side B
S
SM standard
B
SM grade B / SM elite for MTP
K
Reel_PL_600x400x530
8
Divider
S
Small divider (Lite, Compact, ATC)
M
MM standard
U
Crimped divider small
L
V
Crimped divider medium
MM low loss / MM elite for MTP
HUBER+SUHNER Data center
18
Connector overview Connector description
Connector type
Assembly class S
B
M
L
UPC
APC
UPC
APC
PC
PC
•
•
•
•
•
•
w/o connector
00
LC duplex (classic, push-pull, HD)
88/LC Duplex 89/LC APC Duplex
•
•
LC XD
8X/LC-XD PC Duplex 8Y/LC-XD APC Duplex
•
•
MTP® without pins, 12 fiber (female)
52
•
•
•
MTP® with pins, 12 fiber (male)
53
•
•
•
MTP® without pins, 24 fiber (female)
56
•
•
•
MTP® with pins, 24 fiber (male)
57
•
•
•
«Performance class» please see standard assembly catalogue.
Drum type cable system and max. length in meters Air reel
I Plastic reel small
J Plastic reel medium
K Plastic reel large
Item no.
N/A
84144609
84144608
84144607
Dimensions of reel
N/A
600 × 600 × 181 mm
600 × 600 × 331 mm
600 × 600 × 530 mm
Weight of reel
N/A
2.6 kg
3.0 kg
4.5 kg
Item no. cardboard box
N/A
84144616
84144615
84144614
Dimensions cardboard box
N/A
635 × 610 × 195 mm
635 × 610 × 345 mm
635 × 610 × 550 mm
Cable diameter
Maximum length per reel
Ø 3.00 mm Ø 3.60 mm Ø 5.00 mm Ø 7.50 mm Ø 8.00 mm Ø 8.50 mm Ø 9.00 mm
−100 m −60 m −50 m −50 m −50 m −50 m −50 m
−900 m −800 m −400 m −150 m −150 m −130 m −120 m
−1900 m −1300 m −700 m −350 m −300 m −250 m −250 m
−3000 m −2000 m −1200 m −600 m −500 m −500 m −500 m
< 10 kg
< 20 kg
< 37 kg
Weight up to
HUBER+SUHNER Data center
27
LC patch cords Characteristics • 1.8 mm duplex cable for LC-Classic and 2.1 mm for LC-XD uniboot • Low smoke and free of halogen (LSFH™) • Multimode OM4, OM3 and singlemode fiber • Simple polarity flipping with duplex clips • Colour coded connector shrouds (OM4 heather violet, OM3 aqua, SM yellow) • Fast patching with push-pull LC technology • Unlimited access with LC-XD • Super low-loss OM4 performance Excellence in connectivity HUBER+SUHNER patch cords are manufactured with the highest quality materials and to the strictest of manufacturing processes. Our aim is to produce patch cords that add value to our customers either by reducing the cable size, enhancing performance or improving the overall usability. In high density applications, customers can choose the innovative LC-XD connector that reduces cable bulk and speeds up the patching and re-patching process. Our unique «push-pull» LC design was the first major step in revolutionising the standard LC. With this major advancement, customers no longer need to limit their cabling designs to the restrictions of standard connectivity.
LC-XD uniboot The LC-XD uniboot is designed to be used for the highest packing density. The connector has an innovative push-pull mechanism which allows efficient handling even in the smallest of spaces. Another feature is the ability of adjusting polarity without having to use any tools.
LC-Classic The LC classic connector from HUBER+SUHNER is on the industry standard simplex or duplex LC which has a clip on the top face of the shroud for engaging the connector key mechanism. Unlike the XD type, the classic requires full finger access to the clip and subsequently is not optimised for environments where high packing density is required.
28
HUBER+SUHNER Data center
Duplex patch cord Duplex patch cord, LC Classic to LC Classic, UPC, duplex cable 2 × 1.8 mm
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
1
85020915
85022112
85011859
2
85020916
85022117
85021407
3
85020917
85022118
85021408
3.5
85020918
85022119
85021409
5
85020920
85022120
85021410
6
85020921
85022121
85021411
7
85020923
85022122
85021412
10
85020924
85022123
85021413
15
85020926
85022124
85021414
20
85020927
85022125
85021415
Duplex patch cord, LC-XD to LC-XD, UPC, cable 2.1 mm
Length, m
Item no. Singlemode
Multimode OM3
Multimode OM4
1
85016597
85022126
85011862
1.5
85023034
85025978
85019833
2
85016599
85022127
85019837
2.5
85025973
85025979
85025985
3
85016600
85022128
85019838
3.5
85020818
85022130
85021394
4
85019951
85025980
85019950
4.5
85025974
85025981
85025986
5
85016601
85022131
85019839
5.5
85025975
85025982
85025987
6
85020819
85022132
85021395
7
85020820
85022133
85021396
10
85016602
85022134
85019840
15
85020821
85022135
85021397
20
85020822
85022136
85021398
25
85025976
85025983
85025988
30
85025977
85025984
85025989
HUBER+SUHNER Data center
29
LC polarity Tx
Rx
Tx
B A
Rx
B A
Tx
Rx
Tx
B A
LC patch cord Type A–B/B–A Key up/Key Up
Rx
B A
LC patch cord Type A–A/B–B Key up/Key Up
• HUBER+SUHNER standard duplex polarity
• HUBER+SUHNER non-standard duplex polarity
• Use whenever each permanent link in a channel
• Use to correct the polarity in a cabling channel where
uses reverse pair positioning, so an uneven number of crosses in the cabling produces correct polarity. • Reverse pair positioning Fiber 1 – Fiber 2 Fiber 2 – Fiber 1 Fiber 3 – Fiber 4 etc.
an even number of crosses is produced.
The standard polarity of patch cords supplied by HUBER+SUHNER is «A–B/B–A» because although the cable is straight, the position of the fibers in the duplex connector is different at each end. When designing an array based link using 12-fiber ribbon cables, it is important to note that a pair-wise flip has to be integrated at one end of the link. However, if the link is designed using the HUBER+SUHNER cross-connect racks then it will not be necessary to use two different types of patch cords. In this instance, a A–B/B–A patch cord can be used everywhere (i.e. within the crossconnect rack and also at each end of the link). Please contact HUBER+SUHNER if you require A–A/B–B patch cords.
30
HUBER+SUHNER Data center
MTP® patch cords Characteristics • Ready to use «plug & play» cable system • Round cable construction • Small outer diameter of 3 mm for 12 fibers (3.6 mm for 24 fibers) • Low smoke and free of halogen (LSFH™) • MTP high-performance connectivity • All fiber types and performances available • 12 fiber MTP and 24 fiber MTP connectors • Packaged on installed-ready reel for lengths > 10 m • Retrofittable «push-pull» clip for high packing density (see page 55) • Low space consumption in racks • Easy handling and routing • Fast traceability with colour coded jacket (OM4 heather violet, OM3 aqua, SM yellow) • Highest performance singlemode and multimode MTP elite connectivity • Scalable for regular moves, adds and changes
Upgrading to 40G and 100G data rates MTP patch cords are used as an upgrade path from 1G and 10G legacy systems to 40G and 100G data rates. The female to male gender configuration allows the MTP patch cord to be connected at one end to active equipment (female connector) and at the other end (male connector) to a pre-existing patch panel or transition module. By removing the pre-existing MTP to LC module and replacing it with a MTP to MTP transition module, the pre-existing backbone cable systems can be utilised. 1G and 10G systems generally use a 12 fiber MTP cable system transitioning to LC connectivity at the front of the panel. However, 40G and 100G links require an 8 fiber and 20 fiber MTP connector respectively. The MTP transition module allows 12 fiber MTP links to be transitioned to either 8 fiber of 20 fiber MTPs within the module. For lengths longer than 10 m, patch cords are packaged on an installed-ready reel. For longer length equipment to equipment links, customers should choose an MTP link assembly as shown on page 12.
HUBER+SUHNER Data center
31
Patch cord MTP-12 female to MTP-12 male patch cord, elite, polarity A
Length, m
Item no. Multimode OM3
Multimode OM4
1
85018927
85018246
2
85018928
85018247
3
85018929
85018248
5
85018930
85018249
7
85018931
85018250
10
85018932
85018245
MTP-24 female to MTP-24 male patch cord, elite, side A/top-row to side B/bottom-row
Length, m
32
Item no. Multimode OM3
Multimode OM4
1
85018933
85018406
2
85018934
85018407
3
85018935
85018408
5
85018936
85018409
7
85018937
85018410
10
85018938
85018405
HUBER+SUHNER Data center
MTP® cleaning products Optipop R refillable cassette cleaners Characteristics • Suitable for MTP and LC connectors • Integrated cartridge for easy handling • Densely woven, non-static microfibers • Trigger mechanism for winding-on • Automatically seals after each clean • Easy to install replacement reels • 400+ cleanings per reel • Robust cloth does not fray or leave fibrous debris See also: MTP cleaning instructions page 76
The Optipop R hand-held cleaner utilises an integrated cartridge of woven microfiber that can be wound-on each time a connector is cleaned. The unique, densely woven microfiber cloth provides superior cleaning performance while minimising static charge. This prevents the end-face from immediately being recontaminated with airborne contaminants.
Order code Description
Item no.
MTP cleaning, Optipop R cassette for MTP female connectors
84097538
MTP cleaning, Optipop R cassette for MTP male connectors
84097539
MTP cleaning, Optipop R cassette refill
84097551
HUBER+SUHNER Data center
33
IBC™ cleaner Characteristics • Suitable for male and female MTP connectors • 600+ cleanings per tool • Cloth made from densely woven microfibers • Cleaning cloth is washed and debris-free • Adapter tip supplied for cleaning unmated connectors • Allows «through-coupler» cleaning for rear of panel connections See also: MTP cleaning instructions page 76
The IBC brand cleaning tools are designed to clean ferrules residing inside an adapter, faceplate or bulkhead. The cleaning tools are simple to use and highly effective at removing oil and dust contaminants. Alternatively, the IBC cleaner can be used to clean unmated connectors by using a different fitting on the front of the nozzle.
Order code Description
Item no.
IBC MTP cleaner male and female
84097537
MTP® cleaning brush Characteristics • Robust metal pin • Dust cover
The MTP cleaning brush is used to remove unwanted debris from the alignment holes of an MTP female connector.
Order code
34
Description
Item no.
MTP cleaning brush
84139205
HUBER+SUHNER Data center
MTP® adapters MTP® adapter SC footprint Characteristics • SC shape footprint • Short flange snap-mount • High quality 2-piece design • Key-up, key-down type • Connector key alignment marking • Compliant with IEC standard 61754-7 and EIA/TIA-604-5 (FOCIS 5) Short flange MTP adapter with integrated fixing spring suitable for all standard SC shaped cut-outs. Description
Performance
Item no.
MTP adapters SC footprint (13.25 × 9.75 mm), black
OM3, OM4
84128644
MTP adapters SC footprint (13.25 × 9.75 mm), green
SM
84089380
50$;25&251(55(/,()
Drawing MTP adapter SC footprint aperture
HUBER+SUHNER Data center
35
MTP® ganged adapters (angled)
Characteristics • Reduces bend radius of connected cables • Screw-type fixing holes • Key-up, key-down type • Connector key alignment marking • Compliant with IEC standard 61754-7 and EIA/TIA-604-5 (FOCIS 5)
Ganged 1 × 2 and 1 × 4 way angled adapters suitable for reducing the bend radius of cables at each side of the adapter. Generally, this type of adapter is used in the vertical areas of equipment cabinets or at the rear of patch panels. Description
Item no.
MTP ganged adapters (angled), 2 ×, black
85004514
MTP ganged adapters (angled), 4 ×, black
85004517
MTP® ganged adapters (straight) Characteristics • Offers highest packing density • Screw-type fixing holes • Key-up, key-down type • Connector key alignment marking • Compliant with IEC standard 61754-7 and EIA/TIA-604-5 (FOCIS 5)
Ganged adapters provide the highest packing density of connectors when space is at a premium. Generally, these types of adapters are used in patch panels close to high density switches so that backbone cables can be connected to equipment fanouts. Similarly, the 1 × 4 and 1 × 6 variants offer a narrow but high density option when adapters are positioned to the side of equipment cabinet rails. HUBER+SUHNER recommend to use the MTP push-pull clip.
36
Description
Item no.
MTP ganged adapters (straight), 4 ×, black
85004515
MTP ganged adapters (straight), 6 ×, black
85004516
MTP ganged adapters (straight),16 ×, black
84146192
HUBER+SUHNER Data center
CDR cable distribution racks Characteristics • Only 300mm deep and completely front-accessible • Lightweight 2-post design for improved access to cables • Available as 900 mm or 1200 mm wide variants • Up to 1620 duplex LC ports per 47U 900mm cabinet • Up to 1080 MPO ports per 47U 1200mm cabinet • Integrated cable over-length management • Perforated doors to match nearby equipment cabinets • Quick release doors without tools • Mount against an unused wall or at the end of row or • Back-to-back mount on a single floor tile of 600 mm • Large apertures for all cable types, sizes and quantities • Fast installation of sub-racks from the front side • Easy mounting of sub-racks with unit position number strips • Side by side mounting with clear cable routing See also: CDR accessories page 40 Fiber trays page 42
Highest packing density for evolving data centers The CDR (Cable Distribution Rack) is a purpose-built high density fiber management rack which serves as a central cross-connect in the main distribution area of data centers. With a footprint depth of only 300 mm, the CDR is fully modular and scalable up to 1620 ports (3240 fibers) using LC connectivity and 1080 ports (25 920 fibers) using MTP connectivity . Users can benefit from a C-shaped construction where all internal sub-elements are completely installable and accessible from the front side. This important feature means that CDRs can be placed back-to-back on a single floor tile or alternatively against an unused wall for minimal space consumption. Designed to match your data center The CDR has been designed to match equipment cabinets in the datacenter and provide a seamless visual transition from passive racks to active racks. The CDR’s perforated curved doors are the same design as those used on the HUBER+SUHNER equipment cabinet range and the same quality look and feel is echoed across the complete portfolio.
Configured to suit your needs
The CDR is 47U high, 300 mm deep and comes in two standard width dimensions of 900 mm and 1200 mm. The 900 mm version is designed for splicing and MTP-LC furcation trays and the 1200 mm version is intended for patching only, whether it be LC or MTP cable systems.
HUBER+SUHNER Data center
37
900 mm wide
The 900 mm wide rack has integrated patch cord management on the right hand side and can facilitate standard fiber trays for pigtail splicing or MTP-LC furcation. Generally the 900 mm wide rack is used for 1G and 10G serial transmission where a standard LC connector interface is required. The 900 mm wide cabinet is supplied as an empty cabinet and then «tray units» can be installed on-site to accept different types of «fiber trays» depending on the required performance or connectivity type.
The tray unit can be fitted to the rack on-site and has a capacity of 15 × patching trays. In a 47U high rack, a maximum of 6 × 7U tray units can be fitted giving an overall capacity of 90 × fiber trays per rack. The tray unit can accommodate MTP or LC patching trays as standard. See page 42 for fiber trays
Characteristics • Rear-mounted 19 inch • Available in 2U, 3U and 7U heights • Universal adapter plate for conduit (splicing) or MTP adapters (plug & play) • Adapter plates for 3 MTP adapters (3 × 12 fibers) • 2 × fiber tray positions per 1U • Integrated patch cord mandrel • Runner mechanism for fiber trays Order code Description
PU
Item no.
CDR 900 with integrated patch cord management and perforated doors, black (47U high, 600 mm and 300 mm door)
1
85029082
7U tray unit for connecting up to 15 MTP transition fiber trays
1
85013562
Note: Please contact your local sales representative for other configurations and types
38
Description
PU
Item no.
2U tray unit for connecting up to 4 MTP transition fiber trays
1
84143144
3U tray unit for connecting up to 6 MTP transition fiber trays
1
84143135
HUBER+SUHNER Data center
1200 mm wide The CDR 1200 is designed as a dedicated «patching rack» and is configured by adding a 300 mm wide cable over-length rack to the left hand side of a standard 900 mm rack. The CDR 1200 is configured so that an equal amount of cable management is provided on both sides of the rack. The 1200 mm wide rack is better suited for patching applications with standard connectivity (patch cords or fan-outs) or 40G and 100G applications where MTP connectivity is required.
The patching tray unit can be fitted to the rack on-site and has a capacity of 15 × patching trays. In a 47U high rack, a maximum of 6 × 7U tray units can be fitted giving an overall capacity of 90 × patching trays per rack.The patching tray unit can accommodate MTP or LC patching trays as standard. See page 42 for patching trays
Characteristics • Suitable for MTP, LC and SC • Available in 2U, 3U and 7U heights • Up to 18 × adapters per slot (0.5U) • Rear-mounted 19 inch • 2 × patch tray positions per 1U • Integrated patch cord mandrels • Runner mechanism for patch trays
Order code Description
PU
Item no.
CDR 900 with integrated patch cord management and perforated doors and side panels, black (47U high, 600 mm and 300 mm door)
1
85029082
CDR 300 with integrated patch cord management and perforated doors without side panels, black (47U high, 300 mm door)
1
85029083
7U sub-rack for patch to patch solution. Accommodates up to 15 patching trays
1
85017847
Note: Please contact your local sales representative for other configurations and types
Description
PU
Item no.
2U sub-rack for patch to patch solution. Accommodates up to 4 patching trays
1
85015635
3U sub-rack for patch to patch solution. Accommodates up to 6 patching trays
1
85015637
HUBER+SUHNER Data center
39
CDR accessories Horizontal patch cord routing channel Characteristics • Patch cord guide for CDR 900 • Facilitates side by side rack patching • Facilitates front to back patching • Can be mounted in the upper or lower position in rack • Protective cover protects the patch cords
Order code Description
PU
Item no.
4U routing channel for top of rack or bottom of rack mounting, silver
1
85029682
Vertical radius plate (required when routing channel is top mounted)
1
85029683
19 inch break-out plate and cover Characteristics • Full width plate for high quantity of cables • Suitable for all cable sizes and fiber counts • Provides strain relief for loose-tubes • Provides central strength member fixation • Protective cover for transition point of fibers • Suitable for top or bottom rack entry • Fast cable installation from the front side • Easy and fast installation of new cables
Order code
40
Description
Item no.
19 inch break-out plate for conduit fixation, black
84088572
Protective cover for 19 inch break-out Plate, black
84076533
HUBER+SUHNER Data center
Conduit Characteristics • Over-sleeve conduit for cable loose-tubes • 30 mm bending radius protection • External diameter 5 mm and internal diameter 3.3 mm • Prevents loose tubes kink damage • Provides excellent strain relief Order code Description
PU
Item no.
Cable conduit, solid wall, black (only for splice applications)
100 m
84014502
Cable conduit, slitted wall, black (only for splice applications)
100 m
85017566
Floor fixing kit Characteristics • Secures rack to concrete substrate • Takes weight load away from tile • Cable protection sleeves for threaded bar • Expanding anchors provide strong fixation • Double nut array prevents loosening during service • Large washers provide excellent support Order code Description
PU
Item no.
Fastening kit for raised computer floors incl. anchors, threaded-rod, nuts and washers)
1
85029106
Fastening kit for solid concrete floors incl. anchor, nuts and washers
1
85091849
Additional rack mandrel kit Characteristics • Front-mountable • Lightweight aluminium • Adjustable dividers to separate cables • Anti-twist • Fast installation with front-mounted cage nut
Order code Description
PU
Item no.
Front mountable mandrel assembly incl. 2 divider plates and end cap
5
85029681
HUBER+SUHNER Data center
41
Fiber trays for splicing, MTP® transition and patching Characteristics • Sliding and pivoting design • Up to 36 × connectors per tray • All connector types possible • Horizontal support for patch cords • OM4 heather violet, OM3 aqua, SM yellow colour denotes performance • Full 30 mm bend radius limitation throughout • High protection of fibers • Clear label platforms for fast traceability • Compact design 0.5U • Flexible platform for all applications (splicing/MTP/splitters/patching) • Fast installation without tools • Easy traceability by colour and label • Side facing design for laser safety • Access to all fibers and connectors from front side See also: ODR optical distribution racks page 37 CDR accessories page 40 ODU optimised distribution unit page 44
Flexible, scalable and accessible The fiber tray is the core connectivity platform used within HUBER+SUHNER’s high density optical distribution racks (ODR). Incoming cables can either be fusion-spliced to pigtails inside the tray or alternatively pre-terminated MTP fan-outs can be factory installed for instant «plug & play» connectivity. This flexibility matches the fluid nature of data centers, offering the highest performance on the one hand and speed and flexibility on the other. The patch tray can be used for topologies that are in the process of migrating from LC connectivity to MTP connectivity. This product is therefore suitable in data centers moving away from 1G and 10G serial transmissions to 40G and 100G parallel optics. Centralised connectivity In its simplest form, each fiber tray inside the ODR represents a link to a remote area or zone in the data center. By connecting patch cords from one fiber tray to another fiber tray inside the same ODR, users can benefit from one centralised connectivity area. This is a much more structured approach to cabling than spontaneously running duplex patch cords from equipment rack to equipment rack. The fiber tray is available in eight colours so customers can allocate different areas in the network by colour which offers a uniquely high level of identification and traceability.
42
HUBER+SUHNER Data center
Order code Singlemode Description
Item no.
2-way MTP tray, 24 fiber MTP-12 male – standard class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A
84088536
2-way MTP tray, 24 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A
84116087
1-way MTP tray, 24 fiber MTP-24 male – standard class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A
85019034
1-way MTP tray, 24 fiber MTP-24 male – elite class,12 LC duplex ports – standard class, yellow, TIA code, polarity A
85019035
3-way MTP tray, 36 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, yellow, TIA code, polarity A
85019037
Yellow tray, 12 duplex adapters, 24 pigtails, TIA colour code, heat shrink comb with protectors 1.5 × 40 mm
85019039
Order code Multimode OM3 Description
Item no.
2-way MTP tray, 24 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, turquoise, TIA code, polarity A
84132645
3-way MTP tray, 36 fiber MTP-12 male – elite class, 12 LC duplex ports – standard class, turquoise, TIA code, polarity A
85011331
1-way MTP tray, 24 fiber MTP-24 male – elite class, 12 LC duplex ports – standard class, turquoise, TIA code, polarity A
85018179
Turquoise tray, 12 duplex adapters, 24 pigtails, TIA colour code, heat shrink comb with protectors 1.5 × 40 mm
85018939
Order code Multimode OM4 Description
Item no.
2-way MTP tray, 24 fiber MTP-12 male – elite class, 12 LC duplex ports – low-loss class, heather violet, TIA code, polarity A
84132648
3-way MTP tray, 36 fiber MTP-12 male – elite class, 12 LC duplex ports – low-loss class, heather violet, TIA code, polarity A
85017721
1-way MTP tray, 24 fiber MTP-24 male – elite class, 12 LC duplex ports – low-loss class, heather violet, TIA code, polarity A
85017536
Heather violet tray, 12 duplex adapters, 24 pigtails, TIA colour code, heat shrink comb with protectors 1.5 × 40 mm
85019038
Order code patching tray Description
Item no.
Patching tray, 12 MTP adapters (transition patching)
85015429
HUBER+SUHNER Data center
43
ODU – optimised distribution unit Characteristics • Integration of LiSA fiber trays supporting splicing solution or LiSA MTP transition solution • Front-mounting allows the use in standard 19” equipment cabinets • Each height unit accommodates 2 LiSA fiber trays • A llows instant access to fiber tray and its connectivity due to runner mechanism • Integral service loop for patch cords • Horizontal and vertical patch cord guides • Integrated patch cord mandrels for bend-radius protection • Patch cord retaining ring ensures safe strain relief of patch cords exiting the unit • Lockable front door offer complete access security • Flexible mounting points at the rear make cable glanding quick and easy See also: Fiber trays page 42 Unique connectivity solution for equipment cabinets The ODU is a sub-rack which allows fiber trays to be integrated into a standard 19 inch equipment cabinet. Flexible mounting options at the rear of the ODU make cable fixation quick and easy and bend-limiting conduits give ultimate protection to the incoming fibers. Patch cords are routed to the front side of the ODU and can either be guided to the rear of the cabinet (around the vertical rail) or vertically along the front of the rail if sufficient side space is available within the cabinet. The ODU has a lockable steel door which provides security to the internal connections. This feature is particularly beneficial in collocation data centers where multiple subscribers occupy the same rack space.
Order code
44
Description
Item no.
Optimised distribution unit, 1U, MTP version, black
84138128
Optimised distribution unit, 2U, MTP version, black
84138122
Optimised distribution unit, 3U, MTP version, black
84138119
HUBER+SUHNER Data center
MTP® modules Standard type
Characteristics • Robust metal construction • Capacity 12 ports • Available in all performances: singlemode and multimode (OM3 and OM4) • Produced with low-bend fiber • Polarity label and port identification affixed • Available with LC duplex, LC quad, SC and E-2000™ • Up to 36 LC duplex connectors / 72 fibers in a 1U panel • Fast tool-less installation • Compact and robust • Compatible with the fixed and sliding zone distribution panel (ZDP), vertical sub-racks and zero space brackets
Standard «plug & play» modules for fast deployment The MTP module acts as a transition point inside or close to equipment racks. MTP connectors on the rear side fan out to 6 or 12 duplex connectors on the front side. This means that patch cords can be connected from the front of the module to equipment ports in the same or adjacent racks.
High density type
Characteristics • Robust metal construction • Capacity 12 or 18 ports • Produced with low-bend fiber • Available in all performances: singlemode and multimode (OM3 and OM4) • Recessed adapters for improved bend radius • Port identification front and top • Available with LC duplex • Up to 144 fibers per 1U HD panel • Fast tool-less installation • Compact and robust • Factory tested «plug & play» system • Compatible with vertical sub-racks, horizontal panels and zero space brackets • Recessed adapters for improved patch cord management
Highest density presentation for in-rack distribution The MTP HD module is the highest density module currently available on the market. This compact unit acts as a termination point inside or close to equipment racks. MTP connectors on the rear side fan out to 12 or 18 LC duplex adapters on the front side. This means that patch cords can be connected from the front of the module to equipment ports in the same or adjacent racks.
HUBER+SUHNER Data center
45
MTP® module standard type Order code Singlemode Description
Item no.
MTP module, black, 24 fiber 2 × MTP-12 male, standard ferrule, 12 LC duplex ports, horizontal orientation, polarity A
84087326
MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, horizontal orientation, polarity A
84116106
MTP module, black, 24 fiber 2 × MTP-12 male, standard ferrule, 6 LC quad adapters, vertical orientation, polarity A
84132165
MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 6 LC quad adapters, vertical orientation, polarity A
84132657
MTP module, black, 12 fiber 1 × MTP-12 male, elite ferrule, 6 LC duplex ports, horizontal orientation, polarity A
84088086
Order code Multimode OM3 Description
Item no.
MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, horizontal orientation, polarity A
84119613
MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 6 LC quad adapters, vertical orientation, polarity A
84132171
MTP module, black, 12 fiber 1 × MTP-12 male, elite ferrule, 6 LC duplex ports, horizontal orientation, polarity A
85022171
Order code Multimode OM4 Description
Item no.
MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, horizontal orientation, polarity A
84116108
MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 6 LC quad adapters, vertical orientation, polarity A
84132658
MTP module, black, 12 fiber 1 × MTP-12 male, elite ferrule, 6 LC duplex ports, horizontal orientation, polarity A
85018140
MTP® module high density type Order code Singlemode Description
Item no.
High density MTP module, black, 24 fiber 2 × MTP-12 male, standard ferrule, 12 LC duplex ports, polarity A
85014130
High density MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, polarity A
84150020
High density MTP module, black, 36 fiber 3 × MTP-12 male, standard ferrule, 18 LC duplex ports, polarity A
85014129
High density MTP module, black, 36 fiber 3 × MTP-12 male, elite ferrule, 18 LC duplex ports, polarity A
84148469
Order code Multimode OM3 Description
Item no.
High density MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex port, polarity A
84150022
High density MTP module, black, 36 fiber 3 × MTP-12 male, elite ferrule, 18 LC duplex ports, polarity A
84150024
Order code Multimode OM4
46
Description
Item no.
High density MTP module, black, 24 fiber 2 × MTP-12 male, elite ferrule, 12 LC duplex ports, polarity A
84150025
High density MTP module, black, 36 fiber 3 × MTP-12 male, elite ferrule, 18 LC duplex ports, polarity A
84148468
HUBER+SUHNER Data center
Universal adapter plates Characteristics • Capacity standard version 12 × MTP/LC duplex adapters • Capacity high density version 18 × MTP/LC duplex adapters • Fast installation with snap-fixation • Port numbering for easy identification • Compatible with a wide array of sub-racks and panels • Standard UAP compatible with sliding and fixed ZDP, vertical sub-racks and zero space brackets • HDUAP compatible with HDZDP and zero space brackets See also: ZDP panels page 49 Zero space brackets page 53
High density patching in panels and sub-racks Universal adapter plates are supplied pre-loaded with adapters and can be fitted to any panel or sub-rack that accepts the highdensity or standard size MTP modules. This allows adapter plates, modules and blind plates to be mixed and matched in the same panel if desired. Adapter plates are generally used in combination with ruggedised fan-outs whereby the fan-out connects to the rear side of the plate and patch cords connect to equipment ports on the front side. Blind versions of the plate are also available in situations where panel positions are to be reserved for later use. When building an MTP link, universal adapter plates are pre-loaded with MTP adapters so that incoming link assemblies can be connected with fan-outs directly to equipment ports. In 40G and 100G applications, the pre-loaded UAP will act as a patching area whereby MTP patch cords can be connected directly to multi-fiber transceivers. All universal adapter plates have recessed adapters which not only improve the bend radius of patch cords but also provide a larger surface area for port numbering and identification.
HUBER+SUHNER Data center
47
Order code universal adapter plates (standard) suitable with sliding and fixed zone distribution panel Description
Performance
Item no.
Universal adapter plates, black, fitted with 12 SM LC duplex adapters (blue)
SM
84099620
Universal adapter plates, black, fitted with 12 LC duplex adapters (turqoise)
OM3
84099623
Universal adapter plates, black, fitted with 12 LC duplex adapters (heather violet)
OM4
84099624
Universal adapter plates, black, fitted with 12 SC-shape MTP adapters (green)
SM
85018178
Universal adapter plates, black, fitted with 12 SC-shape MTP adapters (black)
OM3, OM4
85018177
Description
Performance
Item no.
Universal adapter HD plates, black, fitted with 18 LC duplex adapters (blue)
SM
85009702
Universal adapter HD plates, black, fitted with 18 LC duplex adapters (turqoise)
OM3
85018189
Universal adapter HD plates, black, fitted with 18 LC duplex adapters (heather violet)
OM4
85014433
Universal adapter HD plates, black, fitted with 18 SC-shape MTP adapters (green)
SM
85018176
Universal adapter HD plates, black, fitted with 18 SC-shape MTP adapters (black)
OM3, OM4
85014434
Order code universal adapter plates (HD) suitable with high density zone distribution panel
Order code universal adapter plates (blind plates) suitable with sliding and fixed zone distribution panel Description
Item no.
Universal adapter plates, black
84097107
Order code universal adapter plates (blind plates) suitable with high density zone distribution panel
48
Description
Item no.
Universal adapter HD plates, black
84148846
HUBER+SUHNER Data center
Zone distribution panel for standard modules Sliding
Characteristics • Up to 3 × MTP standard modules or universal adapter plates (or blind plates) • Capacity 36 LC-duplex connections • 3 × independent sliding shelves • Cable tie-off plates at rear • Integrated cable service loop • Access and installation of modules/plates from the front side • Optional radius guides for patch cord support and bend radius protection • Parking area for MTP connectors • Pay as you grow concept See also: MTP standard modules p 45, Universal adapter plates p. 47
Park and patch functionality The ZDP sliding version allows up to three MTP standard modules or universal adapter plates (UAP) to be integrated in a 1U rack space. Three separate sliding trays within the panel allow individual modules or UAP to be installed, accessed or removed at any time without disturbing pre-connected circuits. Unused spaces can be fitted with blind plates. In addition to this, jumper cables can be pre-parked inside the panel so that modules can be added only as and when they are required. Order code Description
Item no.
Zone distribution panel for standard modules, sliding version, black
84088769
Note: T he standard patch cord guide supplied with this product is item no. 84093678 and can be found on page 54. However, all patch cord management brackets are interchangeable between the standard panel and high density panel.
Fixed
Characteristics • Up to 3 × MTP standard modules or universal adapter plates (or blind plates) • Capacity of 36 LC duplex connections • Optional cable manager for rear of panel • Access and installation of modules/plates from the front side • Optional radius guides for patch cord support and bend radius protection • Pay as you grow concept See also: MTP standard modules p 45, Universal adapter plates p. 47
Fixed modules (rear cable manager optional) The ZDP fixed version allows up to three MTP standard modules (MTM) or universal adapter plates (UAP) to be integrated in a single 1U rack space. Unused spaces can be fitted with blind plates. A pivoting cable manager can be added to the rear of the panel so that cable overlength can be managed effectively to the rear of the panel and then away to the side of the rack. Order code Description
Item no.
Zone distribution panel for standard modules, fixed version, black
85003955
Note: For rear cable manager please see zone distribution panels for high density modules (see page 51).
HUBER+SUHNER Data center
49
Zone distribution panel for high density modules Characteristics • Offers industry leading density of 144 fibers or 24 keystone type RJ-45 jacks in 1U height space • Up to 4 × high density MTP modules or high density universal adaptor plates (or blind plates) • Up to 2 × RJ-45 modules • Mix and match fiber and copper technology in the same panel • Optional rear cable manager for cable overlength storage • Access and installation of modules/plates from the front side • Optional radius guides for patch cord support and bend radius protection • Pay as you grow concept See also: High density modules page 45 Universal adapter plates page 47 Unrivalled density in 1U of space The high density zone panel can accommodate up to four high density MTP modules (MTHDM), four high density universal adapter plates (HDUAP) or two RJ-45 modules in a single 1U rack space (unused spaces can be fitted with blind plates) and is normally positioned at the top of servers or switch cabinets. The HD panel provides unrivalled patching density and requires no complex pivoting mechanism to gain access to the connectors. This is possible because the HD module utilises HUBER+SUHNER’s revolutionary LC-XD connector which actually improves access to the connections even when the panel is in a static position. Both, fiber and copper technologies can also be mixed and matched within the same panel to ensure maximum flexibility in a 1U space. Easy access pivoting cable manager An additional cable manager can be fitted to the rear of the panel which allows excess cable to be stored and routed safely away to the sides of the equipment cabinet. The cable manager can be retrofitted if required and a pivoting function makes installation and access faster and easier. Order code Description
Item no.
Zone distribution panel for high density modules
84146158
Patch cord management brackets, black, for high density zone distribution panel 84146158
84146159
Note: N o patch cord guide is supplied with this panel. However, all patch cord management brackets are interchangeable between the standard panel and high density panel.
50
HUBER+SUHNER Data center
Copper modules Characteristics • Robust steel construction • 12 port capacity in 3 × 4 port blocks • Compatible with keystone mounting type • Suitable for UTP and shielded cabling • Earth bonding lugs fitted to left and right on rear of the module • Port identification front and top • Compatible with the high density zone distribution panel (ZDPHD) • Up to 24 ports per 1U ZDPHD panel • Cable fixation on the back of the module • Fast, tool-less installation RJ-45 module for in-rack distribution The module fits into the high-density ZDPHD patch panel, ideally suited for equipment rack cabling distribution in RJ-45 as well as Fiber optics and accommodates up to 12 keystone mounted RJ-45 jacks per module. The compact unit acts as a termination point inside or close to equipment racks and has incoming cable fixation points on the rear of the module. Two lugs ensure the earth bonding of the entire panel, including jacks, which are themselves earthed on the front of the module. Order code Description
Item no.
RJ45 module, black, for up to 12 × keystone jacks
85029057
RJ45 connector cat. 6A, shielded, keystone mounting, female, 180°, silver
85030606
RJ45 connector cat. 6, unshielded, keystone mounting, female, 180°, black
85001694
Rear cable manager Characteristics • Retrofittable • Pivoting for easy access to MTP connectors • 35 mm minimum bend radius • 1U high • Robust steel and aluminium construction • Colour black
Easy access pivoting cable manager An additional cable manager can be fitted to the rear of the panel which allows excess cable to be stored and routed safely away to the sides of the equipment cabinet. The cable manager can be retrofitted if required and a pivoting function makes installation and access faster and easier. Order code Description
Item no.
Rear cable manager, black, retrofittable, for high density zone distribution panel and zone distribution panel for standard modules (fixed version)
84146157
HUBER+SUHNER Data center
51
Zone distribution sub-rack 3U Characteristics • Up to 336 fibers per 3U (not including 1U patch cord manager) • Up to 14 × MTP standard modules or universal adapter plates (or blind plates) per chassis • Optional 1U patch cord manager • Robust steel construction • 19 inch front mounted • High density connectivity in only 4U of space (3U sub-rack plus 1U patch cord manager) • Fast installation and removal of modules • Easy access to patch cords • 30 mm bend radius protection of fibers • Tidy presentation of patch cords in rack • Complete front access to all fibers once installed • Pay as you grow concept See also: MTP standard modules page 45 High density module presentation in-rack The zone distribution sub-rack allows up to 14 × standard modules to be assembled vertically within a 4U (incl. 1U patch cord manager) high chassis. Each module has a capacity of 24 × fibers which gives a total capacity of 336 fibers using LC connectivity. The optional 1U patch cord manager guides patch cords to the right or the left side of the rack and bend limiters maintain a minimum bend radius of 30 mm.
Patch cord manager (optional) Characteristics • 30 mm minimum bend radius • 1U high • Robust steel construction • 19 inch front mounted • Colour: black with blue mandrels
Managing patch cords with the cable manager
An additional cable manager can be fitted to the front of the Zone distribution sub-rack (3U) which guides patch cords to the right or the left side of the rack and bend limiters maintain a minimum bend radius of 30 mm.
Order code
52
Description
Item no.
Zone distribution sub-rack 3U, black
85024932
1U patch cord manager, black
85024933
HUBER+SUHNER Data center
Zero space module brackets Characteristics • 3U high for standard module • 5U high for HD module • Robust steel construction • Suitable for left or right handed rail • Open fixing slots for accurate adjustment • Module alignment guides at rear • Multiple height fixing options • Retrofittable • Available for HD and standard modules • Suitable for universal adapter plates also • Allows in-rack fiber connectivity without consuming valuable rack space • Can be added to racks where there is no available space for fiber panels • Does not require special tooling • Fits to any rack provided there is free space to the side of the rail See also: MTP standard and high density modules page 45 Universal adapter plates page 47
High density without valuable space consumption Zero space brackets are the perfect solution for bringing fiber connectivity into a rack that is already filled up with active equipment. Simply slide the bracket in front of pre-installed equipment to provide a close proximity patching field either on the right or left side of the cabinet rails. Zero space brackets are retrofittable which means that regardless of future network upgrades or technology changes, fiber connectivity can be integrated into the rack at any time. This product is not only intended as a last minute fix. Zero space brackets can play an important role in the design phase of any switch or server cabinet because they allow the rack to be fully configured with active equipment. This not only improves footprint costs but can also improve cable management due to the fact that both the patching and cable guidance are in the vertical space of the cabinet.
Order code Description
Item no.
Zero space bracket 3U accepting 1 × standard module, black
84099852
Zero space bracket 5U accepting 2 × high density modules, black
84148923
HUBER+SUHNER Data center
53
Cabling accessories Patch cord retainer Characteristics • Guides patch cords around 19 inch vertical rails • Suitable for standard 19 inch fixing holes • Provides lateral support and strain relief for patch cords • Height 1U • Left and right mountable (40 mm side space required) • Colours grey and black • 30 mm bend radius Order code Description
Item no.
Patch cord retainer, black
84088889
Patch cord guide Characteristics • Guides patch cords to the side of the rack • Suitable for standard 19 inch fixing holes • Height 1U • Rapstrap tie can be added • Left and right mountable • Colours grey and black • 30 mm bend radius
Order code
54
Description
Item no.
Patch cord guide, black
84093678
HUBER+SUHNER Data center
Cabling accessories Rapstrap Characteristics • Flexible and extremely strong • Moulded plastic creates no debris • Reduces chance of cable jacket damage or fiber micro/ macro-bending • Re-useable (simply cut with scissors) • Suitable for fiber cables and patch cords • Colour black Order code Description
Item no.
Rapstrap cable tie, 48 pcs.
85004339
MTP® push-pull clip Characteristics • Retrofittable to all MTP connectors • Extension pin improves access to connector when densely packed • Colour black • 2-piece design
Order code Description
Item no.
MTP push-pull clip, 50 pcs.
84140388
HUBER+SUHNER Data center
55
Zone distribution Panel Support Frame – PSF Characteristics • Robust steel construction • 19 inch compatible • Available in 2U, 3U and 4U versions • Retrofittable door kit available for 4U version • Flexible mounting options to suit any environment • Can be floor-mounted also (upside down) • Sufficient space for cable guides • Side fixings for customised brackets
Zone distribution offers a high degree of flexibility The panel support frame is a zone distributor that can be mounted above racks either to a cable basket, cable ladder or containment system. High density backbone cables from the main distribution area of the data center are terminated in the PSF and act as a consolidation point in which users can easily patch to nearby server racks. This approach follows the recommendations of various standardisation bodies who recognised the need to recommend a permanent cabling system in the data center with maximum flexibility and scalability. The PSF can be strategically placed above server cabinets so regardless of regular moves, adds and changes; the connection back to the MDA remains unchanged. The mounting brackets on the PSF are fully adjustable and can be adapted to virtually any environment or fixing platform. The frame itself is based on a 19 inch footprint and allows copper or fiber optic panels to be mounted in the available space. The PSF is available in 2U, 3U and 4U height variants so customers can decide how much capacity they need based on the panel density they are using. Generally speaking, the PSF will serve a number of server racks in close proximity. Therefore, it is not necessary to offer extreme density in such a distributor. For customers who require a higher degree of security, the PSF 4U is available with a door kit which can be locked to prevent unwanted user access.Cable guides can be added to the front of the frame or alternatively fixings in the side of the frame allow customised brackets to be mounted.
Order code
56
Description
Item no.
Panel support frame (PSF), 2U, black
85008425
Panel support frame (PSF), 3U, black
85008426
Panel support frame (PSF), 4U, black
85013642
Panel support frame (PSF), incl. door, 4U, black
85008427
Retrofittable door kit for panel support frame (PSF), 4U, black
85013643
HUBER+SUHNER Data center
Underfloor Fixing Brackets – UFB Characteristics • Robust steel construction • Suitable for all 19 inch panels (copper and fiber) • Adjustable to match different sized pedestals • 2U of panel space available • Height adjustable • No tools required to fix to pedestal • Fast installation • Allows a structured cabling design according to standards such as TIA 942 • Provides localised connectivity for fast moves, adds and changes • Fast and flexible positioning anywhere in the data center • Height adjustable to clear existing infrastructure
Flexible mounting under the raised floor The underfloor fixing brackets are a zone distributor that can be mounted underneath the raised computer floor of data centers. Adjustable brackets can be secured to the pedestal so that 19 inch fiber optic and copper panels can be integrated between them. This product is designed exclusively for underfloor applications and allows users to consolidate their structured cabling in strategic areas of the data center. Backbone cables connect to the back of the panels while the front patching area remains free for all of the regular patches that need to be made to nearby server racks. This zone-based approach is particularly effective in data centers where moves, adds and changes are made on a regular basis.
Order code Description
Item no.
Underfloor fixing brackets (UFB), 1U height, black
85014178
Underfloor fixing brackets (UFB), 2U height, black
85014179
Underfloor fixing brackets (UFB), 3U height, black
85014180
HUBER+SUHNER Data center
57
High density blade organiser Characteristics • Compact 2U high construction • Brush-strip cover for cold/hot air blocking • Adjustable brackets to suit different racks • Up to 512 fiber ports per chassis • Central aperture for copper/power cables • Available with high density LC-XD connectors • Highest performance OM4 low-bend cabling • Suitable for cartridges or fan-out systems • Reduces air-flow blocking to equipment • Reduces cable clutter • Easy identification and traceability • Fast and simple blade replacement • Scalable pay as you grow cabling system • Easy handling of connectivity • Customised solutions available for different switch types See also: Ultralite fan-outs page 15 LC patch cords page 28
Innovative solutions for high density SAN switches The high density blade organiser is a 2U high chassis which can be positioned above or below a switch and allows up to 512 harnessed LC ports to be presented with minimal space consumption and air-flow disruption. The HDBO has a total of 8 × slot positions for either cartridges or fan-outs (4 left/4 right). These slots are designed to correspond with the blade positions of the switch so that pre-connectorised tails can be routed directly from the HDBO into their respective port locations. The chassis is 600 mm deep and can be installed by one person thanks to detachable brackets which can be mounted to the rear rails of the rack before the chassis is fixed. There are two types of HDBO chassis available. Customers can choose an HDBO which facilitates a closed cartridge system or alternatively an open ruggedised fan-out approach.
58
HUBER+SUHNER Data center
Cartridge system The sealed cartridge system is designed with MTP adapters presented at the rear and LC or SC fan-out tails exiting through the front aperture. This approach offers a flexible link design because MTP backbone or horizontal cables can be installed before active blades or cartridges are added.
Order code Description
Performance
Item no.
High density blade organiser – cartridge system, black
N/A
84127548
Cartridge for Brocade DCX switch 48-port blade, LC-XD, black
OM4
85029522
Open fan-out system
The fan-out approach allows individual fan-outs to be routed directly from the centralised optical distribution rack to the switch without any additional connections in the link. This approach offers less flexibility than the cartridge system but provides customers with lower link losses between the MDA and switching area. Fan-outs can be supplied with any connector type but generally the LC-XD type (push-pull with extraction finger and uniboot) is recommended because even in the highest density applications, it is significantly faster and easier to add and remove connections than any other product on the market.
Order code Description
Item no.
High density blade organiser – open fan-out system, black
84134701
HUBER+SUHNER Data center
59
Fiber containment Characteristics • Halogen free, RoHS compliant • UV light-resistant • Flame-retardant UL94/V0 • Provides 100 % lateral support for fibers • Radius protected guiding elements • Secure and enclosed protection of fibers • Tool-less assembly • Compatible with all major brands • Resistant to electrical interference • No grounding needed • No specific tool set or skill set required • Quick and easy expansion of network • Accurate cable length calculations • Reduced operational failures and downtime • Faster traceability of circuits • Prolonged protection of fibers in disaster situations
Protecting your investment The HUBER+SUHNER fiber containment solution can be installed underfloor or overhead and provides a secure and stress-free routing channel for fiber optic cabling within a data center. Curved fittings such as crosspieces, tees and elbows are specifically designed to protect fibers so that a minimum bend radius of 30 mm is maintained at all times. Components of the system include straight channels, horizontal and vertical drop-offs and non-intrusive «over-the-top exits» to equipment cabinets. Additionally, all of the necessary mounting brackets and accessories are available to provide a fast and trouble-free installation. Protective covers can also be added to individual components if a higher degree of protection is required.
Lateral support and bend radius protection Unlike conventional cable baskets and ladders, the HUBER+SUHNER fiber containment solution offers lateral support along the complete fiber length. This reduces the risk of macro-bending and micro-bending of the individual cables. Easy installation The modular design of the HUBER+SUHNER fiber containment solution helps planners to meet the immediate capacity requirements of today without comprimising the expansion needs of tomorrow. Straight channels, curved fittings and interconnect components can easily be connected with standard joiners that require no special tooling or training. In addition, HUBER+SUHNER fiber containment solution is compatible with all other major brands and can easily be adapted to fit different environments and architectures. Fast installation In order to reduce installation times and simplify the complete assembly process, HUBER+SUHNER supply all duct components pre-assembled with joiners. This unique feature can reduce installation times by as much as 50 % and reduces a lot of the complexity involved in connecting straight ducts of different lengths to other components. Because a straight duct always requires at least one joiner, we assemble this in the factory so that full-length ducts can be connected in the fastest possible time. We also pre-fit the screws on the unmated side of the joiner to further improve handling and reduce installation times
60
HUBER+SUHNER Data center
Main ducts and covers Order code main ducts Description
Item no.
Main duct (incl. 1 joiner and screws) 100 × 100 × 2000
85029745
Main duct (incl. 1 joiner and screws) 160 × 100 × 2000
85029747
Main duct (incl. 1 joiner and screws) 220 × 100 × 2000
85029748
Main duct (incl. 1 joiner and screws) 300 × 100 × 2000
85029749
Order code main ducts Description
Item no.
Main duct 100 × 100 × 2000
84107786
Main duct 160 × 100 × 2000
84107785
Main duct 220 × 100 × 2000
84107784
Main duct 300 × 100 × 2000
84107783
Order code covers Description
Item no.
Duct cover (incl. clips) 100 × 2000
85029751
Duct cover (incl. clips) 160 × 2000
85029752
Duct cover (incl. clips) 220 × 2000
85029753
Duct cover (incl. clips) 300 × 2000
85029754
Joiners and end caps Order code joiners Description
Item no.
Joiner (incl. screws) 100 × 100
84107835
Joiner (incl. screws) 160 × 100
84107834
Joiner (incl. screws) 220 × 100
84107833
Joiner (incl. screws) 300 × 100
84107832
Order code end caps Description
Item no.
End cap 100 × 100
84107847
End cap 160 × 100
84107846
End cap 220 × 100
84107845
End cap 300 × 100
84107844
HUBER+SUHNER Data center
61
Horizontal crosses and covers Order code horizontal crosses Description
Item no.
Horizontal cross (incl. 2 joiners and screws) 100 × 100
85029759
Horizontal cross (incl. 2 joiners and screws) 160 × 100
85029760
Horizontal cross (incl. 2 joiners and screws) 220 × 100
85029761
Horizontal cross (incl. 2 joiners and screws) 300 × 100
85029762
Order code horizontal cross covers Description
Item no.
Horizontal cross cover 100
84108097
Horizontal cross cover 160
84108096
Horizontal cross cover 220
84108095
Horizontal cross cover 300
84108094
Horizontal tees and covers Order code horizontal tees Description
Item no.
Horizontal tee (incl. 2 joiners and screws) 100 x 100
85029764
Horizontal tee (incl. 2 joiners and screws) 160 x 100
85029765
Horizontal tee (incl. 2 joiners and screws) 220 x 100
85029766
Horizontal tee (incl. 2 joiners and screws) 300 x 100
85029767
Order code horizontal tee covers
62
HUBER+SUHNER Data center
Description
Item no.
Horizontal tee cover 100
84117259
Horizontal tee cover 160
84117258
Horizontal tee cover 220
84117257
Horizontal tee cover 300
84117256
Horizontal elbows and covers Order code horizontal elbows 90° Description
Item no.
Horizontal elbow 90° (incl. 1 joiner and screws) 100 × 100
85029769
Horizontal elbow 90° (incl. 1 joiner and screws) 160 × 100
85029770
Horizontal elbow 90° (incl. 1 joiner and screws) 220 × 100
85029771
Horizontal elbow 90° (incl. 1 joiner and screws) 300 × 100
85029772
Order code horizontal elbow covers 90° Description
Item no.
Horizontal elbow cover 90° 100
84117268
Horizontal elbow cover 90° 160
84117265
Horizontal elbow cover 90° 220
84117263
Horizontal elbow cover 90° 300
84117261
Vertical down elbows and covers Order code vertical down elbow 90° Description
Item no.
Vertical down elbow 90° (incl. 1 joiner and screws) 100 × 100
85029789
Vertical down elbow 90° (incl. 1 joiner and screws) 160 × 100
85029790
Vertical down elbow 90° (incl. 1 joiner and screws) 220 × 100
85029791
Vertical down elbow 90° (incl. 1 joiner and screws) 300 × 100
85029792
Order code vertical down elbow cover 90° Description
Item no.
Vertical down elbow cover 90° 100
84117298
Vertical down elbow cover 90° 160
84117297
Vertical down elbow cover 90° 220
84117296
Vertical down elbow cover 90° 300
84117295
HUBER+SUHNER Data center
63
Vertical up elbows and covers Order code vertical up elbow 90° Description
Item no.
Vertical up elbow 90° (incl. 1 joiner and screws) 100 × 100
85029794
Vertical up elbow 90° (incl. 1 joiner and screws) 160 × 100
85029795
Vertical up elbow 90° (incl. 1 joiner and screws) 220 × 100
85029796
Vertical up elbow 90° (incl. 1 joiner and screws) 300 × 100
85029797
Order code vertical up elbow cover 90° Description
Item no.
Vertical up elbow cover 90° 100
84117308
Vertical up elbow cover 90° 160
84117307
Vertical up elbow cover 90° 220
84117306
Vertical up elbow cover 90° 300
84117305
Trumpet outlets Order code trumpet outlets Description
Item no.
Trumpet outlet (incl. 1 joiner and screws) 100 × 100
85029784
Trumpet outlet (incl. 1 joiner and screws) 160 × 100
85029785
Trumpet outlet (incl. 1 joiner and screws) 220 × 100
85029786
Trumpet outlet (incl. 1 joiner and screws) 300 × 100
85029787
Reducers and covers Order code reducers Description
Item no.
Reducer (incl. 1 joiner and screws) 160 x 100
85029801
Reducer (incl. 1 joiner and screws) 220 x 100
85029802
Reducer (incl. 1 joiner and screws) 300 x 100
85029803
Order code reducer covers
64
HUBER+SUHNER Data center
Description
Item no.
Reducer cover 160
84117319
Reducer cover 220
84117320
Reducer cover 300
84117322
Top outlet drop-offs and covers Order code top outlet drop-offs Description
Item no.
Top outlet drop-off horizontal (incl. 1 joiner and screws) 100×100
85029798
Top outlet drop-off vertical (incl. 1 joiner and screws) 100×100
85029799
Order code top outlet drop-off covers Description
Item no.
Top outlet drop-off cover horizontal 100
84117315
Top outlet drop-off cover vertical 100
84117316
Top outlet mounting brackets, horizontal and vertical Order code top outlet mounting brackets Description
Item no.
Top outlet mounting bracket, horizontal
84107849
Top outlet mounting bracket, vertical
85005492
Mounting material Order code duct fixing bolt Description
Item no.
Duct fixing bolt
84107837
HUBER+SUHNER Data center
65
Training
Training 80
HUBER+SUHNER Data center
67
Data center certified training – D.C.C.T Characteristics • All product and application knowledge provided • Combines theoretical and hands-on content • Can be tailored to your needs • Available worldwide • Available as 1 day or 3 day extended training • Fully understand and manage the HUBER+SUHNER data center portfolio • Achieve HUBER+SUHNER certification • Become eligible for HUBER+SUHNER’s warranty package • Increase your knowledge and grow your business
Increase your knowledge and grow your business The data center certified training program is aimed at installers, system integrators and re-sellers who would like to become a certified partner of HUBER+SUHNER. Participants of this training course will learn how to build a scalable and future-proofed data center using the latest components and sub-systems from the HUBER+SUHNER fiber management portfolio. Successful participants will be eligible to resell, install and warranty installations built using our data center portfolio. The training course is compiled by HUBER+SUHNER and covers the following topics: Part 1: Fiber optic basics (optional and on special request) Part 2: HUBER+SUHNER fiber management in the data center (compulsory) Part 3: Test and measurement in the data center (optional and on special request) All products and applications are covered by the data center certified training, and participants will benefit from a balanced mix of classroom and practical hands-on training. Parts 1 and 3 are based on half-day sessions, whereas part 2 is a full day of intensive training.
Who should attend the training course? • Anyone seeking to become a certified data center partner of HUBER+SUHNER. • Anyone seeking to improve their general fiber and fiber management knowledge. Can the training course be adapted to particular needs? Training courses can be adapted but part 2 «Fiber management in the data center» is compulsory for those companies wishing to become eligible for the extended warranty license. Part 2 provides an in-depth view of structured cabling for data centers, the HUBER+SUHNER approach, HUBER+SUHNER products and cabling technologies. Part 1 and 3 can be chosen as optional courses and depend on the existing knowledge level and individual preferences of our partners. All training courses can be tailored to suit individual needs. Please enquire if you require bespoke training on a particular product type or application. Should you have a request for training other than that shown, please do not hesitate to contact us and we will try to facilitate your needs.
68
HUBER+SUHNER Data center
How many people can attend each training course? To ensure that all participants receive the best possible training and the highest level of teacher interaction we strongly recommend to limit our classroom training to a maximum of eight trainees per training course. Where does the training take place? 3 different training locations are available as follows: • HUBER+SUHNER AG in Herisau, Switzerland • HUBER+SUHNER subsidiary offices worldwide • Partners and customer premises (not on the live network but other facility within customer premises) We strongly recommend that participants travel to our training facility at HUBER+SUHNER AG in Switzerland where they will benefit from a purpose made demonstration facility with all products and equipment at hand. This will provide the highest level of benefit for the attendees. However, we do realise that travelling to Switzerland is not always possible and for that reason we are continuously expanding our training activities and locations across the HUBER+SUHNER global network. Please do not hesitate to contact us should you require regional training in one of our HUBER+SUHNER international sites.
Data center certified partner Certify your excellence As certified data center partner of HUBER+SUHNER, you can leverage our quality and reputation to facilitate your own business growth.
HUBER+SUHNER Data center
69
DC knowledge and best practices
Fiber containment cable capacity
72
MTP connectivity
73
MTP polarity
74
MTP cleaning instructions
76
Patch cords
78
Colour codes
79
Overview of fiber types
80
Standards
81
Glossary
82
HUBER+SUHNER Data center
71
Fiber containment cable capacity Cable capacity Below is a table showing the average capacity of the HUBER+SUHNER RaceWay system depending on different cable types and sizes. It is important to note that the higher quantity figures are based on straight ducting elements that are connected with joiners and do not represent the retrofittable top outlets. The first row however (100 mm × 45 mm), represents the useable space of a top-outlet or horizontal outlet.
40 % Expansion
60 % Capacity
The cable sizes shown in the table below, reflect the various cables we use for backbone links such as MTP link assemblies, MASTERLINES and fan-outs. We have included data about patch cord sizes although we recommend that patch cords are not guided through a ducting system (only in-rack). Careful attention should be given to the capacity of the top outlets because these represent the smallest cross-section when linking two cabinets in the data center. To avoid bottle-necks, make sure that the quantity of cables per cabinet is clearly understood and planned in advance. The cable quantity table below shows an 60 % fill ratio and a 40 % expansion. We recommend that all calculations are based on these figures so as to allow for future expansion and upgrades.
Cable capacity with 60 % fill-ratio Duct size
Cable type and size 1.8 mm duplex
2.1 mm simplex
3 mm simplex
3.6 mm simplex
7.5 mm simplex
8.5 mm simplex
9 mm simplex
13.5 mm simplex
17 mm simplex
4500
420
604
297
218
46
36
33
12
10
10000
940
1382
653
470
101
86
72
29
21
16000
1495
2188
1049
739
163
136
118
50
32
22000
2049
3024
1445
1024
226
187
158
72
46
30000
2805
4118
1980
1394
252
252
217
92
64
Cable capacity with 40 % expansion Duct size
72
Cable type and size 1.8 mm duplex
2.1 mm simplex
3 mm simplex
3.6 mm simplex
7.5 mm simplex
8.5 mm simplex
9 mm simplex
13.5 mm simplex
17 mm simplex
4500
280
402
198
145
30
24
22
8
6
10000
626
921
435
313
67
57
48
19
14
16000
996
1458
699
492
108
90
78
33
21
22000
1366
2016
963
682
150
124
105
48
30
30000
1870
2745
1320
929
168
168
144
61
42
HUBER+SUHNER Data center
MTP® connectivity Key alignment The standard MTP adaptors supplied by HUBER+SUHNER have a key-slot facing upwards on one side of the adaptor and a key-slot facing downwards on the other side of the adaptor. The purpose of this is to ensure that fibers of the same colour/ number line up with each other when mated (using polarity type A). Some competitors use a key up to key up configuration but this is based on a different polarity method than that used by HUBER+SUHNER. Key marking To ease the connection process of MTP, a white mark is placed on the connector and the adaptor which ensures that the connector key lines up with the adaptor key when mated. Gender explanation MTP connectors are available as male (with pins) and female (without pins). A male connector must always be mated to a female connector so that light transfers from one fiber to another. Failure to adhere to this rule will result in a dark connection and possible damage to the connectors. HUBER+SUHNER supply modules, fiber trays and short fan-outs (less than 5m) with a male connector and backbone cables such as link assemblies and MASTERLINES with a female connector. Gender matching requires careful planning, especially when a customised link design is implemented. In some cases (such as links to SAN switches), it may be necessary to eliminate one of the MTP connections and route long fan-outs directly from the switch back to the MDA. In this case, a fan-out with a female connector should be used because it will be connected directly with a male connector at the fiber tray. It is possible with a special shroud removal tool to convert a male connector to a female connector and vice versa. However, this cannot be carried out in a field environment. All gender re-works must be carried out in a HUBER+SUHNER factory to reduce the risk of fiber breakage or connector damage. If you have any doubt about gender matching, please contact our technical support team for guidance. MTP performance Unless otherwise requested, HUBER+SUHNER will supply all multimode OM3 and OM4 assemblies with MTP elite ferrules. This not only ensures that optimum performance is obtained across a mated pair but also allows much longer and more complex links to be constructed without exceeding the specified optical budget. Singlemode assemblies are available with standard and elite ferrules (preferred type) depending on link design and budget considerations. It is important to note that HUBER+SUHNER supply all standard and elite singlemode connectors with a green connector shroud. We do not follow the practice of some manufacturers who prefer to use yellow for elite ferrules and green for the standard ones. Optical performance Performance classes "patch field"
Attenuation "reference measuring" IEC 61300-3-4, method B
IEC 61300-3-6
IL max
IL mean
RL UPC
RL APC
Singlemode standard class
0.30 dB
0.20 dB
> 50 dB
> 85 dB 1)
Multimode standard class
0.25 dB 2)
n/a
> 35 dB
n/a
Multimode low-loss class
0.15 dB
n/a
> 35 dB
n/a
2)
Performance classes "MT"
1)
Singlemode standard class
0.75 dB
0.30 dB
> 50 dB
> 85 dB 1)
Singlemode elite class
0.35 dB
0.15 dB
> 50 dB
> 85 dB 1)
Multimode standard class
0.60 dB 2)
n/a
> 35 dB
n/a
Multimode elite class
0.35 dB 2)
n/a
> 35 dB
n/a
Measurement method 3 (OLCR) Measured with Encircled Flux (EF)
2)
HUBER+SUHNER Data center
73
MTP® polarity $
%
%
$
.H\XS NH\GRZQDGDSWRUV $
%
%
$
Method A (HUBER+SUHNER standard) Method A uses key up to key down adaptors to link straight-through ribbon cables to modules/cassettes. In this respect, fiber 1 is always in the same position when looking at the array connector end-on with the key up. The polarity flip is achieved using a duplex patch cord at one end of the link. HUBER+SUHNER use and recommend method A as standard because all of the array based products are straight-through and it is only the patch cords which are flipped. Duplex clips facilitate simple on-site changes to polarity because simplex connectors can be removed from the clip and swapped over. This is a far safer approach to building an array-based network and for this reason has become the method of choice.
74
HUBER+SUHNER Data center
A
B
B
A
1
12
12
1
Key Up / Key Up adaptors B
A
A
B
12
1
1
12
Method B Method B uses key up to key up adaptors to link straight-through ribbon cables to fiber cassettes/modules. Here, the only difference between method B cassettes and method A is the adaptor. The fiber channel is completed by flipping the second cassette and re-numbering it so that a standard A-B jumper cable can be used to connect them. This method is more complex for planners than method A because fiber numbers no longer correspond with each other (e.g . fiber 1 connects to 12, 2 to 11, 3 to 10 and so on). In addition, method B does not support singlemode installations because the array connector is angled and flipping these angles produces a mismatch.
$
%
%
$
<ĞLJƵƉ ͬŬĞLJĚŽǁŶĂĚĂƉƚŽƌƐ $
%
%
$
Method C Method C uses key up to key down adaptors to link cassettes/modules using a special flipped ribbon jumper assembly. In this configuration, the ribbon cable creates the flip allowing standard straight-through patch cords to be used at each end. On longer channel links where more than one array cable is used, care must be taken to ensure that the flip remains consistent thereby making this method somewhat more complex for planners than method A.
HUBER+SUHNER Data center
75
MTP® cleaning instructions IEC 62627 procedure for exposed connectors
76
1.
Always inspect before cleaning. If the connector is already clean, there is no need to clean it.
2.
Use a dry cleaning method. (Optipop R page 33) a. Remove connector dust cover b. Select the appropriate cleaner for male/female c. For female MTP connectors, use the cleaning brush and fluid to remove any debris from the pin holes d. Depress the green lever so that a fresh area of cleaning cloth is exposed e. Position the ferrule against the cloth so that the fibers are in contact with the cleaning material. In the case of angled connectors, the ferrule will need to be adjusted accordingly. f. Wipe the connector in the direction shown on the cassette g. Release the grip to seal off the cleaning cloth h. Let the ferrule air-dry before inspecting with a 200 × microscope i. If still contaminated repeat all steps once again j. Ensure that the connector does not touch any hard surfaces
3.
If connector is still contaminated, use a wet cleaning method. a. Apply an approved cleaning fluid to a small area of lint-free cleaning cloth b. Wipe the connector over the damp area c. Wipe the connector over a dry area of cloth and allow it to dry d. Re-inspect the ferrule with a 200 × microscope
HUBER+SUHNER Data center
IEC 62627 procedure for in-port connectors
1.
Always inspect before cleaning. If the connector is already clean, there is no need to clean it.
2.
Use a dry cleaning method. (IBC cleaner page 34) a. Insert the IBC cleaner into the adaptor where the connector is mated b. Rotate the tape feeder wheel as indicated on the cleaner c. Inspect the connector with a 200 × microscope d. If still contaminated repeat steps once more
3.
Use a wet cleaning method. a. Insert the cleaning bud through the adaptor and wipe the surface of the connector ferrule b. Insert the IBC cleaner into the adaptor where the connector is mated c. Allow to dry and then inspect the connector with a 200 × microscope d. If still contaminated repeat steps once more
HUBER+SUHNER Data center
77
Patch cords Cable selection HUBER+SUHNER recommend that whenever possible, patch cords should only be used for in-rack connections. This simplifies Moves, Adds and Changes (MACs) and reduces the cable chaos generated by thousands of cross-network 2-fiber connections. Generally speaking, the smallest possible patch cord cable should be used for in-rack applications so that the overall cable mass can be reduced. The introduction of bend-optimised fiber across our range means that cables with a smaller outer diameter can be utilised without running the risk of performance degradation in tight spaces. Calculating patch cord lengths in HUBER+SUHNER racks The rack can either be used as a cross-connect cabinet or as an inter-connect cabinet. When used as a cross-connect solution, high density cables enter the rack from different zones of the data center and patch cords inside the rack cross-connect these different areas. The reason for this design is to reduce the time and complexity of inter-connect systems whereby patch cords are routed spontaneously from one place to another whenever a link is needed. The patch cord management area in the rack has been designed in such a way that links from any fiber tray to any fiber tray can be made with just two different patch cord lengths. This reduces complexity and allows our customers to make much better use of their stock holding. The drawing below shows the rack segmented into two halves (the upper section and the lower section). If a connection is needed between a fiber tray in the upper section of the rack to another fiber tray in the upper section of the rack, then a patch cord of 3.5 m is required. This also applies to connections made from a fiber tray in the lower section of the rack to another fiber tray in the lower section. Generally, we advise our customers to logically split the rack top to bottom so that the majority of connections are made from the top to the bottom and not from the top to top or bottom to bottom. In this case, the length of patch cord needed is 5 m. In some cases, it will be necessary to position more than one rack together so that a higher density cross-connect can be achieved. In such cases, the patch cord lengths will need to be adjusted accordingly. The figure and table hereafter show how the various segments of the racks correspond to different patch cord lengths.
CDR 1
A
78
B
A
3.5 m
5m
CDR 2
C
CDR 3
D
CDR 4
E
F
G
H
9m
8m
10 m
9m
11 m
10 m
B
5 m
3.5 m
8m
5m
9m
6m
10 m
7m
C
9 m
9m
3.5 m
5m
9m
8m
10 m
9m
D
8m
5m
5m
3.5 m
8m
5m
9m
9m
E
10 m
9m
9m
8m
3.5 m
5m
9m
8m
F
9m
9m
9m
5m
5m
3.5 m
8m
5m
G
11 m
10 m
10 m
9m
9m
8m
3.5 m
5m
H
10 m
7m
9m
9m
8m
5m
5m
3.5 m
HUBER+SUHNER Data center
Colour codes Colour codes for fiber according to standard Number
TIA/EIA-5981
1
blue
2
orange
3
green
4
brown
5
grey
6
natural/white
7
red
8
black
9
yellow
10
violet
11
pink
12
turqoise
1 EN 50174-1
HUBER+SUHNER Data center
79
Overview fiber types Fiber data for transmission Fiber E9/125 Wavelength [nm]
Fiber G50/125 (OM3/OM4)
1310
1550
850
1300
Attenuation [dB/km] (typical)
0.35
0.21
2.30
0.55
Attenuation [dB/km] (max.)
0.40
0.25
≤2.70
≤1
Core Ø [µm]
9.2 ±0.4 1)
10.4 ±0.8 1)
50 ±2.5
Cladding Ø [µm]
125 ±1
125 ±2
Coating Ø [µm]
245 ±10
245 ±10
Standards
• ITU G.652-D
• ITU G.651
• IEC 60793-2-50 type B1.3
• IEC 60793-2-10 type A1a.2 + A1a.3
1)
Mode field Ø
Link lengths for standardised fiber types Wavelength
Multimode G50/125
Singlemode E9/125
Fiber class according to HUBER+SUHNER
F
G
Stand. fiber types as per ISO/IEC 11801:2002 and amend. 2 (2010)
OM3
OM4
850 nm
1500
3500
Min. modal bandwith overfilled launch bandwidth [MHz*km]
1300 nm
500
500
Min. modal bandwith effective laser launch bandwith 2) [MHz*km]
850 nm
2000
4700
Channel Length (MAX)/ Channel IL (MAX)
1000BASE-SX
850 nm
1000 m/3.56 dB 3)
1100 m/3.56 dB 3)
1000BASE-LX
1300/ 1310 nm
550 m/2.35 dB 3)
550 m/2.35 dB 3)
10GBASE-SR/SW
850 nm
300 m/2.59 dB
550 m/2.59 dB 3)
10GBASE-LX4 (CWDM)
1300 nm
300 m/1.96 dB
550 m/1.96 dB 3)
Application
Standards
5000/4.56 dB
10GBASE-LR/LW
1270 nm
10000/6.2 dB
10GBASE-ER/EW
1550 nm
27250/10.9 dB
40GBASE-SR4
850 nm
40GBASE-LR4 (CWDM)
1310 nm
100GBASE-SR10
850 nm
100GBASE-LR4 (DWDM)
1310 nm
100GBASE-ER4 (DWDM) Attenuation TYP/MAX [dB/Km]
OS2
100/1.9 dB
150/1.53 dB 10000/6.7 dB
100/1.9 dB
150/1.53 dB 10000/6.7 dB
1550 nm
40000/18.0 dB
850 nm
2.30/2.50
2.30/2.50
1300 nm
0.55/0.70
0.55/0.70
1310 nm
0.35/0.40
1550 nm
0.21/0.25 ITU G.651
ITU G.651
ITU G652-D
IEC 60793-2-10 type A1a and A1a2
IEC 60793-2-10 type A1a and A1a2
IEC 60793-2-50 type B1.3
DIN VDE 0888, part 3
DIN VDE 0888, part 3
DIN VDE 0888, part 3
According to IEEE 802.3, ISO/IEC 11801-2nd edition Effective Laser Launch Bandwidth is assured using DMD as specified in IEC/PAS 60793-1-49 3) T his specification of this type of cabled optical glass was not defined when this application was ratified however channel lengths indicated are guaranteed by HUBER + SUHNER 1)
2)
80
HUBER+SUHNER Data center
Standards Standards governing the design, installation, commissioning and operation of structured cabling systems, and the particular environments they operate within can be complex and confusing. There are 3 main standardisation bodies across the world and depending on where the installation takes place, they have an order of precedence. Internationally, the International Organisation for Standardisation (ISO) is the main body for producing such standards and in support of ISO the International Electrotechnical Commission (IEC), produces the standards for the relevant components. In Europe, CENELEC (European Committee for Electrotechnical Standardisation) is the overall authority for the production of standards. Various national committees also exist in many of the European countries and may take their national standards from any of the main standards bodies, or may develop their own. Typically though, normative European standards (EN) are adopted by those national standards bodies. In the Americas (including Canada), the TIA is the dominant standards body, although the structure of its standards is slightly different (and in some cases conflicting) to that of ISO and CENELEC. There tends to be more harmonisation with CENELEC and ISO standards bodies, although some of the differences with TIA are only nomenclature. HUBER+SUHNER, as a global company, supplying a globally-suitable product, references International Standards as a preference. This does not mean that relevant national standards are not complied with due to local standards always taking precedence, but this is typically most relevant in the design and installation requirements rather than components that a manufacturer may supply. These main standards are listed below: ISO/IEC 11801:2002 and A.1:2008 ISO/IEC 24764 Edition 1.0 2010-04
- Information technology – Generic cabling for customer premises - Information technology – Generic cabling systems for data centers
These documents also reference component standards where applicable. ISO/IEC 14763-1:1999 + A.1:2004 ISO/IEC TR3 14763-2:1999 ISO/IEC 18010:2002 + A.1:2005 ISO/IEC 14763-3:2006 IEC 61280-4-1:2009 IEC 61935-1:2008 IEC 61935-3:2008
- Information technology – Implementation and operation of customer premises cabling – Part 1: Administration - Information technology – Implementation and operation of customer premises cabling – Part 2: Planning and installation - Information technology – Pathways and spaces for customer premises cabling - Information technology – Implementation and operation of customer premises cabling – Part 3: Testing of optical fibre cabling - Fibre-optic communication subsystem test procedures – Part 4-1: Installed cable plant – Multimode attenuation measurement - Generic cabling systems – Specification for the testing of balanced communication cabling in accordance with ISO/IEC 11801 – Part 1: Installed cabling - Testing of balanced communication cabling in accordance with ISO/IEC 11801 – Part 3: Verification and qualification in accordance with ISO/IEC 15018
HUBER+SUHNER Data center
81
Glossary
82
Balanced cable
A cable construction technology used in copper structured cabling systems that generally utilises 4 pairs of twisted conductors, which are "balanced" together to provide a suitable medium for data transmission when used in conjunction with suitable connectors (typically RJ45 type). Can be produced in shielded (screened) or unscreened form. The balancing ensures consistent performance on each pair.
CDR
Cable distribution rack – interconnects incoming and outgoing optical fiber in a controlled way. Each fiber can be connected to every other fiber within the rack by simple patching.
CENELEC
European committee for electrotechnical standardization – the governing standards body within EU that covers structured cabling systems. Closely aligned to ISO standards in technical content.
Data center
A data center is a facility that provides space and services in order to host IT equipment. Services include power, cooling, connectivity, security and management.
EDA
Equipment distribution area
EIA
Electronic industries alliance
EN
European normative – a designation given to a standard written by the CENELEC organisation that has applicability throughout the EU.
F/FTP
A term used to describe the detailed construction of a balanced cable – stands for foil overall shield, with each pair individually foil covered.
F/UTP
A term used to describe the detailed construction of a balanced cable – stands for foil overall shield, with each pair unshielded.
Fiber tray
A splice or distribution module with telescopic hinged functionality holding fibers, splice connections and/or adaptors. The fiber tray has lateral fiber access to adaptors called side access.
FOCIS
Fiber optic connector intermateability standard, referenced to TIA/EIA. Generally used in North America.
HDBO
High density blade organiser
IEC
International electrotechnical commission – the standards body that typically provides the standards that cover component performance, often in conjunction with ISO.
IEEE
Institute of electrical and electronics engineers – the body that produces many of the applications standards, particularly those of the ethernet type.
ISO
International organization for standardization
LC
Lucent connector, type of optical fiber connector
LC-Classic
LC connector according industry standard type. A conventional key and clip mechanism is used.
LFF
Large form factor (connector) – such as SC, ST type.
Link losses
The sum of all losses in a fiber cabling system and includes fiber attenuation factor, mated connector pairs and splices but excludes equipment cord cable attenuation and the equipment connection itself.
LSFH™
An acronym used to describe the characteristics of the standard HUBER+SUHNER cable jacket material – which stands for "low smoke and free of halogen".
HUBER+SUHNER Data center
MAC
Moves, adds and changes – the sometimes complex process by which users, equipment and services are altered and reprovisioned.
MDA
Main distribution area – the area that houses the distributor used to make connections between the main distribution cabling sub-system, network access cabling sub-system and cabling subsystems (as specified in ISO/IEC 11801) and active equipment.
MASTERLINE
The MTP MASTERLINE cable system from HUBER+SUHNER is purpose made for high density backbone/horizontal connections between racks or zones in the data center.
MCM
Multi-circuit management – a type of splice tray design that allows multiple optical circuits (often 24 or 48 fibers) to be managed in a single splice tray.
MM
Multi mode (or multimode) – an optical technology description which is generally used in short distance communications (sub 2 km) but basically describes the method by which the light passes along the glass - by multiple "mode" or paths. Requires less precision of components to ensure alignment of the core (50 - 62.5 microns) but needs a more complex manufacturing method for the glass.
MTP
Mechanical transfer push-pull - an enhanced version of the MPO connector offering higher optical perfomance, repeatability and reliability.
MTP link assemblies
Cable assemblies using 12 fiber cable with MTP connectors terminated at either end.
MPO
Multi-fiber push-on – an optical connector, standardised under IEC 61754-7:2008 (multimode only) which provides an interface for up to 72 fibers in a single unit, utilising individual rows of 12 fibers in a polymeric ferrule.
NGR
New generation rack
ODU
Optimised distribution unit – sub-rack that houses fiber trays and can be front mounted to any 19 inch rack.
OM1
Optical multimode class 1 – typically is only now available in the market with 62.5 µm diameter core and is the lowest bandwidth commercially available. No longer recognised by standards as suitable for installation in a DC.
OM2
Optical multimode class 2 – typically is only now available in the market with 50 µm diameter core and is considered the minimum bandwidth suitable for LAN applications, but does offer extremely limited application support for any application above 1GB/s. No longer recognised by Standards as suitable for installation in a DC.
OM3
Optical multimode class 3 – only available in the market with 50 µm diameter core and is now considered the minimum bandwidth suitable for LAN and Data Center applications. It is the first "laser optimised" multimode optical fiber and was developed to provide increaded bandwidth (and hence reach) for VCSEL 850 nm opto-electronnic devices, such as used in 10GBASE-SR.
OM4
Optical multimode class 4 – only available in the market with 50 µm diameter core and is now considered the most future-proofed class, suitable for LAN and Data Center applications. It is the second "laser optimised" multimode optical fiber, offering more than double the bandwidth of OM3 at the critical 850 nm wavelength.
OS1
Optical singlemode class 1 – this is the de-facto standard singlemode fiber and has been utilised for many years where applications need to be delivered over extended distances (i.e. >1 km).
OS2
Optical singlemode class 2 þ this is often described as "low water peak" singlemode, and offers both lower attenuation and a flatter attenuation curve in the wavelengths of 1310 and 1550 nm, allowing wave division multiplexing-based applications to utilise the previously unavailable zone found between those wavelengths.
Patch cord
Ruggedised cable assembly with connectors on both ends used to cross-connect individual links. Can also be used to connect links to transceivers and when added to a link, create a channel.
HUBER+SUHNER Data center
83
84
Pigtail
Cable assembly with connector on one end; typically cable Ø 0.9 mm
RJ45
Registered jack, type 45 – a term generally used to describe a 8P (8 position), 8C (8 contact) RJ-style connector, and can be gendered male of female. Typically supplied in ethernet transceivers and then used in the structurd cabling system within the LAN and data center. Cabling systems using this connector are typically limited to a channel length of 100 m with a maximum of 4 connections at 500 MHz and category 6A/class EA channels.
SAN
Storage area network: A network that is designed specifically for the needs of storage devices. Often a separate cabling system is used due to the frequent use of the FC (fiberchannel) transmission protocol and specific FC transceivers.
SC
Subscriber connector, a type of optical fiber connector
SCM
Single-circuit management. Generally refers to a cassette that houses only 1 or 2 fibers.
SFF
Small-form-factor connector with a Ø 1.25 mm ferrule, this size allows a higher packing density. Available types: LX.5, LC, MU etc.
S/FTP
A term used to describe the detailed construction of a balanced cable – stands for braid overall shield, with each pair individually foil covered.
Side access
Adaptors and connectors are side facing
SM
Single mode (or singlemode) – an optical technology description which is generally used in long distance communications but basically describes the method by which the light passes along the glass – by a single "mode" or path. Requires a greater precision of components to ensure alignment of the very small core (8 to 10 microns).
Splice
Permanent joint between 2 optical fibers, created by fusion (heat), clamping or gluing.
TIA
Telecoms industry association – U.S standards creation body for structured cabling systems, also generally adopted by canadian standards asssociation.
Transition assembly
An assembly of cabled optical fibers and connectors, with an array connector at one end and simplex or duplex connectors at the other end. Typically used within a plug & play cassette or to make the final connections into a switch blade.
U/FTP
A term used to describe the detailed construction of a balanced cable – stands for no overall shield, with each pair individually foil covered.
U/UTP
A term used to describe the detailed construction of a balanced cable – stands for no overall shield, with each pair unshielded. More commonly referred to as "UTP".
ZDA
Zone distribution area
ZDP
Zone distribution panel
HUBER+SUHNER Data center
Enter a world full of benefits: datacenter.hubersuhner.com On our data center web platform, you will find more detailed and up-to-date facts on our solutions, including additional examples of projects, documentations, videos and more.
HUBER+SUHNER Data center
85
Further catalogues All our catalogues are updated regularly. They are available in electronic format and can be accessed from our main HUBER+SUHNER homepage. Simply go to the «Downloads» section and select «Fiber Optics» and «Catalogues» to filter down your search. http://hubersuhner.com/en/Service-Contact/Downloads