D AT A C E N T R E P O W E R A N D C O O L I N G 11.0
Data Centre Power and Cooling With power costs continuing to rise, the ability to maximise a data centre’s energy efficiency has rapidly become one of the most critical considerations for network infrastructure professionals. To meet this growing challenge, Siemon has developed a solution set that addresses energy efficiency from two key angles — cooling and power distribution:
Section Contents Cold Aisle Containment System . . . . . . . . . . . . . . .11.1 - 11.2 Intelligent Power Distribution Units . . . . . . . . . . . . . . . . . .11.3 Metered PDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.4 Monitored and Smart PDUs . . . . . . . . . . . . . . . . . . . . . . .11.5 Switched and Managed PDUs . . . . . . . . . . . . . . . . . . . . .11.6 Intelligent PDU Accessories . . . . . . . . . . . . . . . . . . . . . . .11.7
www.siemon.com
The Cold Aisle Containment System is a passive cooling solution which can be easily applied to improve the efficiency or expand the capacity of a data centre with minimal incremental cost. By containing the cold air supply and isolating it from the rest of the room, cold aisle containment prevents mixing of cold and hot air. The room’s perimeter cooling system can now operate more efficiently because it does not have to compensate for the detrimental impact of mixed airflow. This allows the cooling system to operate at higher temperatures while still sufficiently and safely cooling the equipment. Higher temperatures reduce energy costs through lower fan speeds, higher chilled water temperatures, and more frequent use of free cooling. This efficiency also provides additional capacity to cool greater heat densities with the existing cooling system without investing in more costly active supplemental cooling products.
Easy to Install — Quickly and easily attaches to VersaPOD®, V600 and V800 cabinets
www.siemon.com
Retrofittable — Leverages existing perimeter cooling system and hot aisle / cold aisle arrangement
D AT A C E N T R E P O W E R A N D C O O L I N G
Cold Aisle Containment System
Thermal Isolation — Robust seals and selfclosing doors ensure optimal isolation between hot and cold air
11.1
D AT A C E N T R E P O W E R A N D C O O L I N G
Product Information PERFORMANCE SPECIFICATIONS Material – Windows
Polycarbonate 4mm
Material – Metal Components
CRS
Finish
Textured powder coat
Colour
Black (RAL 9011)
Light Transmission
87%
Ordering Information: Roof Panels 1200mm wide top frame panels with window Part # Description VC-RP-V6N-A12B ....................................V600 VC-RP-V8N-A12B ....................................V800 VC-RP-VPN-A12B....................................VersaPOD® VC-RP-VPS-A12B....................................SidePOD™
End Panels 1200mm wide end panel with window to fill aisle space opposite the door Part # Description VC-EP-B12B ............................................End panel, 42U VC-EP-A12B ............................................End panel, 45U VC-EP-C12B ............................................End panel, 48U
Accessories Part # Description VC-WM-V6N-AB ......................................Wall mount bracket, V600 VC-WM-V8N-AB ......................................Wall mount bracket, V800 VC-WM-VPN-AB ......................................Wall mount bracket, VersaPOD VC-WM-VPS-AB ......................................Wall mount bracket, SidePOD VC-RB-V6N-AB ........................................Riser bracket, 3U, V600 VC-RB-V8N-AB ........................................Riser bracket, 3U, V800 VC-RB-VPN-AB........................................Riser bracket, 3U, VersaPOD VC-RB-VPS-AB........................................Riser bracket, 3U, SidePOD
Door Kits Solid doors with window(s), no lock Part #
Description
VC-DR-SSL-AB ....................................Single self closing left, 45U VC-DR-SSN-AB....................................Single self closing right, 45U VC-DR-SML-AB....................................Single manual closing left, 45U VC-DR-SMR-AB ..................................Single manual closing right, 45U VC-DR-DSN-AB ..................................Double self closing, 45U VC-DR-DMN-AB ..................................Double manual closing, 45U VC-DR-SAB-CB....................................Single door adjustment bracket, 48U VC-DR-DAB-CB ..................................Double door adjustment bracket, 48U
Filler Panels Solid filler panels to fill spaces where cabinets are not present, such as where columns or other obstructions exists Part # Description
VC-FP-V6N-BB ....................................V600, 42U VC-FP-V6N-AB ....................................V600, 45U VC-FP-V6N-CB ....................................V600, 48U VC-FP-V8N-BB ....................................V800, 42U VC-FP-V8N-AB ....................................V800, 45U VC-FP-V8N-CB ....................................V800, 48U VC-FP-VPN-BB ....................................VersaPOD, 42U VC-FP-VPN-AB ....................................VersaPOD, 45U VC-FP-VPS-BB ....................................SidePOD, 42U VC-FP-VPS-AB ....................................SidePOD, 45U
11.2
www.siemon.com
Siemon’s line of intelligent PDUs provide valuable energy consumption data while reliably delivering power to critical IT equipment. Each of our PDU families deliver real-time power information with varying degrees of intelligent functionality ranging from basic Metered units to full-featured Managed PDUs — providing multiple options based on the level of data and control requirements, Siemon’s intelligent PDUs may be used as stand-alone units, or they can communicate with third-party software through common open networking protocols. All of our network-capable intelligent PDUs also have the capacity to connect environmental sensors, allowing temperature, airflow, and humidity to be measured to further troubleshoot and optimise data centre efficiency.
PDU Families
FUNCTION
Metered Monitored Smart Switched Managed
METERED
MONITORED
SMART
SWITCHED
MANAGED
Built-In Display for Local Use
√
√
√
√
√
PDU-Level Monitoring
√
√
√
√
√
Remote Monitoring via Ethernet Port
√
√
√
√
Environmental Sensor Ports
√
√
√
√
Locking Outlets
√
√
√
Outlet-Level Monitoring
√
Configurations
Mounting
Various plug inputs
√
Vertical PDUs mount via toolless button attachments and include a mounting bracket for additional flexibility
Single and 3-phase voltages Horizontal and Zero-U vertical styles
√ √
Outlet-Level Switching/ Control
D AT A C E N T R E P O W E R A N D C O O L I N G
Intelligent Power Distribution Units
Horizontal PDUs mount to standard EIA 19 in. configurations
3m cords (other lengths available on request) Test data included with each unit
www.siemon.com
11.3
D AT A C E N T R E P O W E R A N D C O O L I N G
Metered PDUs Metered PDUs provide local visual monitoring capability through a built-in LED meter that displays realtime consumption data. Metered PDUs are a cost-effective alternative to monitored or switched PDUs when remote monitoring is not desired, while providing a more intelligent alternative to basic PDUs. The 3 phase and 60A units measure current (amps) that scrolls through each phase
Single-phase PDUs measure power by scrolling through power factor, amps, volts and watts
Ordering Information Mounting
Input Current
Input Voltage
Power
Input Plug
Output Receptacles
Output Receptacles
Length
Part Number
Metered International
11.4
Horizontal 1U
32A
230V
7.3kW
IEC 309 2P+E
IEC C13 (12)
-
432mm
7TH22-BA12Z-K1A
Vertical
16A
230V
3.6kW
IEC 309 2P+E
IEC C13 (24)
IEC C19 (6)
1683mm
7TV20-BA24E-K1A
Vertical
32A
230V
7.3kW
IEC 309 2P+E
IEC C13 (24)
IEC C19 (6)
1683mm
7TV22-BA24E-K1A
www.siemon.com
Building on the functionality of the Metered family, Monitored and Smart PDUs enable different levels of remote monitoring of power consumption.
Alarm conditions with high or low thresholds, notification via buzzer, email, or SNMP trap
Monitored PDUs
Remote monitoring is established via an RJ45 port for network connection. Data can be downloaded in PDA, XML and SNMP formats
Monitored PDUs collect data at an aggregate, device-level, generating a smaller quantity of information to simplify management.
Smart PDUs Smart PDUs offer the highest level of monitoring by providing outlet-level data collection.
Units have environmental monitoring capabilities through two RJ12 ports to support two separately purchased sensors directly, or up to 16 sensors connected via splitters
The LCD display provides the ability to view power data locally. Display is customisable for data type, unit of measure and unique device naming
The browser-based interface is used to view charts and logs without the need for additional software
The unit provides remote and local alarms and utilisation logging
D AT A C E N T R E P O W E R A N D C O O L I N G
Monitored and Smart PDUs
Ordering Information Mounting
Input Current
Input Voltage
Power
Input Plug
Output Receptacles
Output Receptacles
Length
Part Number
Monitored International Horizontal 1U
16A
230V
3.6kW
IEC C20
IEC C13 (12)
-
432mm
7MH33-BA12Z-K1A
Vertical
16A
230V
3.6kW
IEC 309 2P+E
IEC C13 (24)
IEC C19 (6)
1683mm
7MV20-BA24E-K1A
Vertical
32A
230V
7.3kW
IEC 309 2P+E
IEC C13 (24)
IEC C19 (6)
1683mm
7MV22-BA24E-K1A
Vertical
16A
230/400V WYE
11kW
IEC 309 3P+N+E
IEC C13 (24)
IEC C19 (6)
1683mm
7MV26BA24E-K1A
Vertical
32A
230/400V WYE
22kW
IEC 309 3P+N+E
IEC C13 (24)
IEC C19 (6)
1683mm
7MV27-BA24E-K1A
Smart International Vertical
16A
230V
3.6kW
IEC 309 2P+E
IEC C13 (18)
IEC C19 (6)
1683mm
7NV20-BA18E-K1A
Vertical
32A
230V
7.3kW
IEC 309 2P+E
IEC C13 (18)
IEC C19 (6)
1829mm
7NV22-BA18E-K1A
Vertical
16A
230/400V WYE
11kW
IEC 309 3P+N+E
IEC C13 (18)
IEC C19 (6)
1683mm
7NV26-BA18E-K1A
Vertical
32A
230/400V WYE
22kW
IEC 309 3P+N+E
IEC C13 (18)
IEC C19 (6)
1829mm
7NV27-BA18E-K1A
www.siemon.com
11.5
D AT A C E N T E R P O W E R A N D C O O L I N G
Switched and Managed PDUs In addition to power monitoring, switched and managed PDUs enable users to remotely control individual receptacles by allowing equipment to be restarted or remotely shut down.
Switched PDUs Switched PDUs combine total PDU power monitoring with portlevel switching. They are the ideal solution when port control is needed but only aggregate consumption data is desired.
Units have environmental monitoring capabilities through two RJ12 ports to support two separately purchased sensors directly, or up to 16 sensors connected via splitters
Remote monitoring is established via an RJ45 port for network connection. Data can be downloaded in PDA, XML and SNMP formats
Managed PDUs Managed PDUs offer the highest level of control and monitoring by providing outlet-level monitoring and outlet-level switching.
User definable URL for each outlet
The LCD display provides the ability to view power data locally. Display customisable data type, unit of measure and data outlet status
Sequential start up and shut down to manage loads The browser-based interface is used to access charts, logs, and alarms
Ordering Information Mounting
Input Current
Input Voltage
Power
Input Plug
Output Receptacles
Output Receptacles
Length
Part Number
Switched International Vertical
16A
230V
3.6kW
IEC 309 2P+E
IEC C13 (21)
IEC C19 (3)
1683mm
7SV20-BA21C-K1A
Vertical
32A
230V
7.3kW
IEC 309 2P+E
IEC C13 (20)
IEC C19 (4)
1778mm
7SV22-BA20D-K1A
Vertical
16A
230/400V WYE
11kW
IEC 309 3P+N+E
IEC C13 (21)
IEC C19 (3)
1683mm
7SV26-BA21C-K1A
Vertical
32A
230/400V WYE
22kW
IEC 309 3P+N+E
IEC C13 (21)
IEC C19 (3)
1829mm
7SV27-BA21C-K1A
7WH22-BA08Z-K1A
Managed International
11.6
Horizontal 1U
32A
230V
7.3kW
IEC 309 2P+E
IEC C13 (8)
-
432mm
Vertical
16A
230V
3.6kW
IEC 309 2P+E
IEC C13 (21)
IEC C19 (3)
1683mm
7WV20-BA21C-K1A
Vertical
32A
230V
7.3kW
IEC 309 2P+E
IEC C13 (20)
IEC C19 (4)
1778mm
7WV22-BA20D-K1A
Vertical
16A
230/400V WYE
11kW
IEC 309 3P+N+E
IEC C13 (21)
IEC C19 (3)
1683mm
7WV26-BA21C-K1A
Vertical
32A
230/400V WYE
22kW
IEC 309 3P+N+E
IEC C13 (21)
IEC C19 (3)
1829mm
7WV27-BA21C-K1A
www.siemon.com
Environmental Sensors
7ENS-TEMP ............................... Temperature Sensor
7ENS-TEMPHAF ........................ Temperature/ Airflow/ Humidity Sensor
7ENS-WATER............................. Water Sensor
7ENA-SPLIT-5............................. Splitter RJ12 x 5 way
7ENS-WKIT ................................ Water Sensor Cable
D AT A C E N T R E P O W E R A N D C O O L I N G
Accessories
SPECIFICATIONS General Safety Compliance Emissions Cord Length Circuit breakers Outlet Colour Coding Material Finish Warranty
CE (International PDUs only) FCC Part 15 Class A 3m 32A units On 3 phase units for load balancing 18 Gauge Steel Black powder coat 3 Years
Environmental Operating Temperature Storage Temperature
10 to 40°C -25 to 65°C
Operating Humidity
5% to 95% (non-condensing)
Storage Humidity
5% to 95% (non-condensing)
Operating Elevation
0 to 2000m
Storage Elevation
0 to 15240m
Networking Networking Protocols Ethernet Link Speed Data Formats
www.siemon.com
(not applicable to metered units) HTTP, HTTPS (SSL/TLS), SMTP, POP3, ICMP, DHCP, TCP/IP, NTP, Telnet, Syslog 10 Mbit; half-duplex HTML, SNMP, CSV/Plain Text, XML
11.7