Transcript
12 Fiber MPO MultiMode Patch Cables
The 12 fiber MPO Multimode patch cables are designed for datacenter solutions supporting the topologies as specified in the datacenter standards EN50173-5, ISO/IEC 24764 and TIA-942. The 12 fiber MPO patch cables support datacenter applications such as 10-40-100 Gigabit Ethernet, 4-8-16G Fibre Channel or InfiniBand. 12 fiber MPO female/female A (or C) wired patch cables are used to connect 12 fiber MPO cassettes. 12 fiber MPO female/female B wired patch cables are used as direct connect cables between 40/100GbE transceivers. MPO male/female patch patch cables enable a channel to be built with MPO female/female trunks and MPO coupler modules. When the MPO cable is connected with MPO, one of the MPO connectors must have pins. The 12 fiber MPO patch cables use 3.2mm round, indoor rated cable.
Features • Pre-terminated low loss MPO patch cable • OM3 OPTOBEND bend insensitive fiber glass in an LSZH round cable jacket • Intermated MPO performance for OM3: Attenuation ≤0.5 dB(max.) and Return Loss ≥25 dB(min)
1
For more information, visit commscope.com
12 Fiber MPO MultiMode Patch Cables
Specification (The following content can be copied and pasted directly into tender response documents. Choose your preferred option from content inside [x,y,z].) MPOptimate 12 fiber patch cables are a 12 fiber bend insensitive [OM3] LSZH, indoor cable with a diameter of 3.2mm. The LSZH outer jacket color are AQUA with a flammability rating according IEC 60332 Parts 1 and 3. One side of the cable shall have a [male-female] MPO connector and the other side shall have a [male-female] MPO connector. The wiremap shall be [type A, straight/type B, total flipped/type C, pair flipped].
Typical applications and wire map:
Type A or type C cable:
Type B cable:
MPO patch cables are available in 3 different wire map configurations. Straight - Type A wiring
Total flipped - Type B Wiring
Pair flipped - Type C wiring
Fiber
Fiber
Fiber
Fiber
Fiber
Fiber
1
1
1
12
1
2
2
2
2
11
2
1
3
3
3
10
3
4
4
4
4
9
4
3
5
5
5
8
5
6
6
6
6
7
6
5
7
7
7
6
7
8
8
8
8
5
8
7
9
9
9
4
9
10
10
10
10
3
10
9
11
11
11
2
11
12
12
12
12
1
12
11
2
For more information, visit commscope.com
12 Fiber MPO MultiMode Patch Cables
Technical Details Connector type MPO/MTP
12 fiber (1 row) low loss MPO connector
† The MTP multi-fiber connector is US Conec’s trademarked name for an improved MPO connector. The CommScope MPO connectors meet and exceed the MTP performance.
Optical Characteristics Intermated MPO Attenuation
OM3 ≤0.5dB
Intermated MPO Return Loss
OM3 ≥25dB
OM3 fiber
OPTOBEND bend insensitive fiber , IEC 60793-2-10 type A1a.2 / A1a.3, ISO/IEC 11801 OM3 / OM4, TIA/EIA-492AAAC / 492AAAD
OM3 bandwidth
OFL bandwidth ≥ 1500 MHz.km @ 850nm /EMB ≥2000MHz.km @ 850nm
Mechanical Characteristics Operating Temperature
-10 to +60°C
Flammability
IEC 60332 Parts 1 and 3
Approvals/Compliant Structured cabling
ISO/IEC 11801 / Cenelec EN 50173-1 / TIA-568 C.0
Data Center
Cenelec EN 50173-5 / ISO/IEC 24764/ TIA-942
Application
Ethernet IEEE 802.3; 10/40/100GbE / Fiber Channel PI5; 4-8-16G / InfiniBand Architecture spec Volume 2
Connectors
IEC61754-4.20; IEC61754-7; IEC 61300-3-30; TIA 604-5-D (FOCIS 5); EN50377-15-1 RoHS Compliant
† Specifications subject to change without notice.
Ordering Information Description **
Lengths*
Wire map
12 fiber MPO female –female, OM3
0-80 meter
straight A wire
Part Number y-2160134-x
12 fiber MPO male-female, OM3
0-80 meter
straight A wire
y-2160138-x
12 fiber MPO male-male, OM3
0-80 meter
straight A wire
y-2160423-x
12 fiber MPO female –female, OM3
0-80 meter
straight B wire
y-2160192-x
12 fiber MPO male-female, OM3
0-80 meter
straight B wire
y-2160196-x
12 fiber MPO female –female, OM3
0-80 meter
pair flipped C wire
y-2160200-x
12 fiber MPO male-male, OM3
0-80 meter
pair flipped C wire
y-2160691-x
** for OM4 MPO patch cables see the CommScope MPOptimate MPO patch cable spec sheet * X and Y indicate the length of the patch cable. Cable lengths (“L”) from 0-80 meter are defined in length table with part number 2160070. Note: MPO Patch cables lengths are measured from end to end.
3
For more information, visit commscope.com
www.commscope.com Visit our website or contact your local CommScope representative for more information. © 2015 CommScope, Inc. All rights reserved. MPOptimate and all trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. PS-321222.1-EU (12/15)