Data Sheet RJ45 Telecom Surge Protectors
MJ8-ISDN, MJ8-170V
34
44
P
D
54
Line
Mounting Flange
• • • • • •
Rail DIN mounting
Screw lug
Protection for one telephone line For PSTN, ISDN, ADSL lines Quick installation RJ45 connectors IEC 61643-21 compliance UL497A
Characteristics CITEL Model
MJ8-ISDN
Description
RJ45 surge protector for 1 ISDN line ISDN
Network Max. data rate SPD configuration Pin outs
MJ8-170V
Surge protector for telephone line 1 to 4-pairs RTC, ADSL2, SDSL, SHDSL, VDSL2 - 4 pairs 30 Mbps 4 pairs + shielded 4-pairs (1-2)(3-6)(4-5)(7-8) 150 Vdc 170 Vdc 1000 mA > 10 MHz < 1 dB 2000 A
Nominal line voltage Max. DC operating voltage Max. Load current (if connection serie) Max. frequency Insertion loss Line/Ground Nominal discharge current
Un Uc IL f max In
30 Mbps 2 pairs + shielded 2-pairs (3-6)(4-5) 48 Vdc 60 Vdc 1000 mA > 10 MHz < 1 dB 2000 A
Nominal discharge current Line/Line
In
500 A
500 A
Iimp Up
500 A 70 V Short-circuit
500 A 220 V Short-circuit
8/20µs Test x 10 - C2 category
8/20µs Test x 10 - C2 category Impulse current - 2 x 10/350µs Test - D1 Category
Protection level Failsafe behavior
Mechnical characteristics Dimensions Format Connection to Network Disconnection indicator Mounting Operating temperature Protection rating Housing material Standards compliance
Part number
see diagram RJ45 connector RJ45 connector female input/output transmission interrupt Mounting flange,Screw lug, DIN Rail -40/+85°C IP20 Aluminium IEC 61643-21 / EN 61643-21 / UL497A 560209 560203
LISTED
CITEL • 2 rue Troyon • 92316 Sèvres Cedex • France • Tel.: +33 1 41 23 50 23 • Fax: +33 1 41 23 50 09 • e-mail:
[email protected] • www.citel.fr F120103B • Document could be modified without notice
P : 3-pole gas tube R : Resistor D : Clamping Diode