DATA SHEET Alkaline Order code 18-3455
Manufacturer code MN1500K4
Description PK 4 MN1500 AA ULTRA BATTERY
Alkaline The enclosed information is believed to be correct, Information may change ‘without notice’ due to product improvement. Users should ensure that the product is suitable for their use. E. & O. E. Sales: 01206 751166
[email protected]
Technical: 01206 835555
[email protected]
Page 1 of 3 Revision A 04/07/2003
Fax: 01206 7551188 www.rapidelectronics.co.uk
Zn/MnO2
MX1500 Size: AA (LR6) Alkaline-Manganese Dioxide Battery Nominal Voltage:
14.5 mm 13.5 1.0 mm MIN.
5.5 mm Max.
1.5 V
Nominal Internal Impedance:
81 m-ohm @ 1kHz
Average Weight:
24.4 gm (0.86 oz.) 3
8.4 cm (0.51 in. )
Terminals:
Flat
Operating Temperature Range:
-20 C to 54 C o o (-4 F to 130 F)
NEDA/ANSI: IEC:
15A LR6
(+)
50.5 mm 49.2
3
Volume:
o
o
Discharge Characteristics at Various Power Drains 1.6
(–) 1.00 W 1.5 0.75 W
Dimensions shown are IEC/ANSI standards
1.4 0.50 W
Voltage
1.3
0.25 W
1.2
1.1
1
Typical Ultra AA Discharge Characteristics
0.9
0.8 0
1.6
2
4
6
8
10
Service Hours 1.00 A 1.5 0.75 A 1.4 0.50 A
Voltage
1.3
0.25 A
1.2
1.1
1
0.9
o o All testing at 21 C (70 F)
0.8 0
1
2
3
4
5
6
7
8
9
10
Service Hours
* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
5/04
12
Zn/MnO2
MX1500 Size: AA (LR6) Alkaline-Manganese Dioxide Battery
Delivered Energy vs Power Drain 10
Energy (Wh)
1.1 V 1.0 V 0.9 V
1
Delivered Capacity vs Power Drain
0.5 5
10
100
1000
Power (mW)
10 1.1 Volts
Ampere Hours
1.0 Volts 0.9 Volts
1
Service Hours vs Power Drain 1000
0.5 5
10
100
1000 1.1 Volts
Power (mW)
1.0 Volts
o o All testing at 21 C (70 F)
Service Hours
0.9 Volts 100
0.8 Volts
10
Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 Internet: www. duracell .com
1 5
10
100
1000
Power (mW)
* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information