Preview only show first 10 pages with watermark. For full document please download

Data Sheet And Installation Information

   EMBED


Share

Transcript

Data sheet and installation information 1. Machine configuration and overall dimensions e'2 / e'2m / cup heater e'2 / e'2m e'2m / fridge e'2 e'2m e'2m cup heater e'2m fridge w/h/d mm w/h/d (inch) 560/713/600 (22 / 27.9 / 23.6) 560/713/600 (22 / 27.9 / 23.6) 840/713/600 (33 / 27.9 / 23.6) 840/713/600 (33 / 27.9 / 23.6) weight kg weight (lb) 83 183 87 191 112 246 117 257 Capacity Coffee Steam Hot Water Milk system 175 Espresso / hour at 23s extraction time 2 Espresso at the same time Manual steam, continuous steam supply Autosteam, temperature controlled Everfoam, fully automatic frothing (option) 150 hot water units / hour, 200ml (6.8 oz US) 175 Cappuccino / hour Technical data Brew chamber Grinding User Interface Bean hoppers Coffee spout hgt Interface Standby mode Steam boiler size Coffee boiler size Lighting concept 1 x up to 24g 2 x super drive ceramic grinder disk 1 x 8" color touch screen 2 x 1.5kg (3.3 lb) 65mm to165mm (2.55 to 6.49 inch) USB, SD-Card, Ethernet, Serial, RS-232, CCI less than 2W e'2: 8 litre (2.11 gal US) e'2m: 5.6 litre (1.48 gal US) 1.5 litre (0.39 gal US) Front panel full color LED Power requirement Single-phase Two-phases Three-phases Water Connection Water Water hose Drain 1 x 230V, 1L-N-PE, 30A, 50/60Hz, 5.8kW 1 x 208V, 2L-PE, 30A, 50/60Hz, 4.9kW 3 x 230V, 3L-N-PE, 16A, 50/60Hz, 8.6kW G3/8" female, 2.5 - 4 bar 2 m length (78.7 inch) Self priming (see drawing rear side) Water quality Total hardness: 5 - 8°dGH (89-142 ppm) Carbonate hardness: max. 6°dKH (107 ppm) pH value: ideal 7.0 - 7.2 Fridge 4 litre container (1.05 gal US) Milk tube length max 1.5m (59 inch) 556 (21.89) 713 (28.07) 70 (2.7) 125 (4.92) 65 (2.56) 157 (6.45) 165 (6.49) Dimensions: mm (inch) 560 (22) 840 (33) Eversys AG I Rue du Biais 19 I 1957 Ardon I Switzerland 150113_Data_sheet_and_installation_e2_4001_EN 600 (23.6) +41 27 305 25 50 Page_1_of_2 [email protected] www.eversys.com 01.2015 / V1 2. Prior to the installation, READ SAFETY INSTRUCTIONS • • • • • • Check water quality Define filter type and size and check space inside counter If no descaling cartridge is used, install carbon filter as minimum Check required desk for machine Check counter cut out Check water supply installation • • • • • • Check power supply installation Check all with customer on site Make sure original coffee is available Make sure cold milk is available Check drinks recipes and cup sizes Organize milk pitcher • Fill in installation warranty sheet and send it back to Eversys 3. After installation • Instruct staff using Quick reference card 4. Desk preparation mm (inch) Drill hole according to instruction of refrigerator manufacturer Dimensions: mm (inch) Place fridge as close as possible to machine Cut milk tubes as short as possible 420 (16,54) Grounds chute through the desk Cut out on desk for: - Power cord - Water hose - Serial port - Ethernet 141,2 (5,56) Ø 54 ( 2,13 ) Required space for bean hopper refilling 63 (2,48) 356 (14,02) 153 (6,02) 348 800 (31,5) (13,7) 158 (6,22) Ø 80 ( 3,15 ) 180,8 (7,12) 93 (3,66) R 26,5 (1,04 ) Water inlet 3/8" 800 (31,5) 400 (15,75 ) 5 Grounds container Drain hose 23 mm (inner ø0.6 inch) 3 Fridge example 6 Foot position 4 Cut out on desk for Ground chute (optional) 2 Execution according to EN 61770 1. 2. 3. 4. 5. 6. 1 Main water inlet Pressure reducer output 3 bar (43,5 psi) Check valve Descaling cartridge or carbon filter as minimum Electrical socket according to local standard Drain with syphon, top end min. 56mm diameter (2.2 inch) Eversys AG I Rue du Biais 19 I 1957 Ardon I Switzerland 150113_Data_sheet_and_installation_e2_4001_EN +41 27 305 25 50 Page_2_of_2 [email protected] www.eversys.com 01.2015 / V1