Transcript
General
1 2 3 4 5 6
Environment
Switch
Actuator
Options
Accessories
Certifications
7 8 9
Instrument Data Sheet Safety Stop Switch / Pull Cord Switch RS-2 Conveyor Components Company
Product Model Number Manufacturer Certified Ambient Temperature Functional Ambient Temperature Enclosure Material Enclosure Rating (UL) Enclosure Rating (CSA)
0 to 40 °C [32 to 104 °F] -50 to 85 °C [-58 to 185 °F] (increased actuation force may be required below -30 °C [-22 °F]) 319 cast aluminum NEMA Type 1, 3, 3R, 4, 4X NEMA Type 3, 4, 4X 3 holes at Ø 13/32” [10 mm] (Vertical surface mounting standard, bracket available for horizontal surfaces)
10
Mounting
11 12 13 14
Switch Type Contact Type Contact Rating (UL)
15
Contact Rating (CSA)
16 17 18 19 20
Electrical Action Electrical Connection Indicating Lamp
21
Cable Length
22
Cable Material
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
Mechanism Non-activated Position Activated Position Range of Travel Action Actuation Force
Pull cord switch Maximum 100’ [30.5 m] on each side of the unit (maximum 200’ [61 m] total) Ø 3/32“ [2 mm] 7x7 galvanized aircraft cable: orange vinyl or nylon coated to Ø 3/16“ [5 mm] OD Lever with rotating cam Rotated fully clockwise Rotated fully counter-clockwise 60° counter-clockwise from non-activated position Latching (To reset, push lever inward and rotate clockwise) Field adjustable
Finish
Uncoated (standard) or epoxy (option E) coating
Mounting Bracket Cable
RS-30 available for horizontal surface mount Orange vinyl (RS-25) or nylon (RS-26) coated cable available
UL Listing File CSA Certification File
NMFT.E83971 71174
Type
SPDT x 2 Dry contact 20A @ 125V, 250V or 480V AC; 1 hp @ 125V AC; 2 hp @ 250V AC 20A @ 125V, 250V or 480V AC; 1 hp @ 125V AC; 2 hp @ 250V AC; ½ A @ 125V DC; ¼ A @ 250V DC Latching (via actuator) ¾" NPT x 3 None
Conveyor Components Company Division of Material Control, Inc. 130 Seltzer Road, PO Box 167 Manufacturer 40 Croswell, MI 48422 USA (810) 679-4211
[email protected] www.conveyorcomponents.com Notes: 1. Cable must be supported with eyebolts. Maximum spacing: 10’ [3 m]. 2. Maximum of 100’ [30.5 m] of cable may be attached to each side of the unit; 200’ [61 m] total.
®
DATA-0002 Rev01; Appd: JK
©Copyright Conveyor Components Co. 2014 Division of Material Control, Inc.
Page 1 of 1