Preview only show first 10 pages with watermark. For full document please download

Data Sheet - Huber+suhner

   EMBED


Share

Transcript

Data Sheet Coaxial Cable RG_216_/U Description PE-75 Ohm - double screen Technical Data Construction Material Detail Diameter Centre conductor Copper, Tin plated Strand-07 1.2 mm Dielectric PE (Polyethylene) Outer conductor Copper Braid, 95% 8 mm Outer conductor Copper Braid, 93 % 8.7 mm Jacket PVC II (low migration) RAL 9005 - bk 10.8 mm +/- 0.15 7.25 mm Print: HUBER+SUHNER RG 216 U 75 Ohm (PA no.) Electrical Data Impedance Operating Frequency Capacitance Velocity of signal propagation Signal delay Insulation resistance 75 Ω +/- 3 2 GHz 67 pF/m 66 % 5.03 ns/m ≥ 1 x 108 MΩm ≥ 70 dB (up to 2 GHz) ≤ 5 kVrms (at sea level) 10 kVrms (50 Hz/1 min) Min. screening effectiveness Max. operating voltage Test voltage Mechanical Data Weight Min. bending radius static repeated (for ≤ 50 bendings) 16.7 kg/100 m 55 mm 110 mm Environmental Data Temperature range Installation temperature 2011/65/EU (RoHS) -25 °C... +85 °C -20 °C... +60 °C compliant Additional Information Ordering Information Order as RG_216_/U Remarks (For details refer to the HUBER+SUHNER RF CABLES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner) Suitable Connectors Cable group U36 7 mm / 75 Ohm Document: DOC-0000177767 AJ / PDO N / date of publication: 05.09.2017 14:10:46 / uncontrolled copy Page 1/2 Data Sheet Coaxial Cable RG_216_/U Matrix Coefficients: typical Attenuation [ formula: (a*f^0.5 + b*f) ] and maximum Power CW [ formula: (p/f^0.5) ] a = 0.2002 b = 0.0835 fmax = 2 P at 1GHz = 290 Frequency Nom. attenuation Nom. attenuation Max. CW power (GHz) (dB / m) (dB / ft) (watt) sea level 25° C ambient temperature sea level 25° C ambient temperature sea level 40° C ambient temperature 0,1 0,07 0,022 917 0,2 0,11 0,032 648 0,3 0,13 0,041 529 0,4 0,16 0,049 459 0,5 0,18 0,056 410 0,6 0,21 0,063 374 0,7 0,23 0,069 347 0,8 0,25 0,075 324 0,9 0,27 0,081 306 1,0 0,28 0,086 290 1,1 0,3 0,092 277 1,2 0,32 0,097 265 1,3 0,34 0,103 254 1,4 0,35 0,108 245 1,5 0,37 0,113 237 1,6 0,39 0,118 229 1,7 0,4 0,123 222 1,8 0,42 0,128 216 1,9 0,43 0,132 210 2,0 0,45 0,137 205 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000177767 AJ / PDO N / date of publication: 05.09.2017 14:10:46 / uncontrolled copy Page 2/2