Transcript
ENSURE CONTINUITY OF POWER SUPPLY
DATA SHEET
COLD START START FROM BATTERY
SPECLINE 700 700 VA LONG BACKUP TIME
CLEAR DIGITAL SINUS SYSTEM (CDS)
COOL BATTERY CHARGING SYSTEM (CBC)
The UPS SPECLINE 700 protects the devices that are connected to it against the network power loss, power drops and prevents damage resulting from surges in the power network. SPECLINE 700 UPS is designed to primarily protect the operation of central heating boilers, pumps, control and automation systems. UPS offers longer duty time by adding additional EVER battery packs. An alternative way to extend the backup time is to use a car battery.
FEATURES • Clear Digital Sinus (CDS) - system that enables the battery back-up to generate true sine wave output voltage in battery operation mode • Intelligent battery charging system called - which extends the battery life by using the components of the internal inverter • Synchronisation with the mains • Microprocessor control of all the parameters • Discharged battery sound indication • Automatic switch to supply from mains after return of voltage with required parameters. • Option to add up to 3 battery packs and a car charger with a capacity of up to 150 Ah • System of passive mains filters • "Cold start" - starting without the need to be connected to the power source • Resistance to overloads • Short circuit protection • Convenient universal method of cable connection
SERVICE • Door-to-door support • 2-year warranty for the UPS • Execution in 14 working days
2015-12-01 EN
www.ever.eu
SPECLINE 700 700 VA
TECHNICAL DATA
Note: The manufacturer reserves the right to modify the above parameters without prior notification.
PARAMETERS \ TYPE Part number Rated output power (Apparent / Active) 1) The maximum output power of 30 s (Apparent / Active) GENERAL DATA AND ENVIRONMENTAL Topology Number of phases (in/out) Housing Type Operating temperature 2) Storage temperature Relative humidity during operation Relative humidity during storage Operating elevation 3) Protection level Environment of installation Cooling INPUT Rated input voltage Input voltage range and tolerance Input voltage rated frequency Input voltage frequency range and tolerance Transfer thresholds: Mains – UPS OUTPUT Rated output voltage Output voltage range and tolerance - normal mode Output voltage range and tolerance - battery mode Shape of output voltage (battery mode / normal mode) Output voltage rated frequency Output frequency range and tolerance - mains operation mode Output frequency range and tolerance - battery mode Output voltage filtering Transfer thresholds: UPS– Mains Transfer time to battery mode Transfer time to normal mode BATTERIES AND TYPICAL RUNTIME Internal Batteries External Batteries Maximum number of EBMs 42 Ah Maximum capacity of external battery Backup time - 1 EBM (100 %/50 % PZN) Backup time - 2 EBM (100 %/50 % PZN) Backup time - 3 EBM (100 %/50 % PZN) Rated voltage DC circuit EBM (42 Ah) Maximum charging time - after discharging at 80 % Pmax*
SPECLINE 700 W/SPECTO-000K70/00 350 VA / 200 W 700 VA / 400 W VFD (offline) 1/1 Tower 0 ÷ +40 °C 0 ÷ +45 °C 20 ÷ 80 % (non-condensing) 20 ÷ 95 % (non-condensing) < 1000 m IP20 Technical rooms / industrial rooms with low level of pollution Gravity 230 V AC ~ 184 ÷ 264 V ± 2 % 50 Hz 45 ÷ 55 Hz ± 1 Hz ~ 184 ÷ 264 V ± 2 % 230 V AC ~ 184 ÷ 264 V ± 2 % ~230 V ± 5 % Sine wave / same as input 50 Hz Synchronously 50 Hz ± 1Hz LC, RFI/EMI filter, varistor TVSS ~ 189 V / 259 V ± 2 % < 3 ms 0 ms None 6 x 12 V / 7 Ah VRLA 3 150 Ah 85 / 200 min 200 / 473 min 340 / 700 min 12 V DC 10 h
* Charging time to 90% battery capacity, following a prior discharge with a load of 80% Pmax (to shut down the UPS). Notes: 1) For standard operation, the load applied to the output must not exceed 80% of the value in the table. The power margin is necessary to ensure continuous work of the connected devices in the case of instantaneous surges of the load. 2) For UPS with internal batteries 5 ÷ 35 °C. Constant exposure of the battery module to temperatures of +25°C reduces the battery life. 3) The permitted maximum load of the power supply unit decreases with the height above the sea level above the limit specified above.
2015-12-01 EN
www.ever.eu
SPECLINE 700 700 VA
PARAMETRYDATA TECHNICZNE TECHNICAL
Note: The manufacturer reserves the right to modify the above parameters without prior notification.
PARAMETERS \ TYPE
SPECLINE 700
Part number Rated output power (Apparent / Active) 1) The maximum output power of 30 s (Apparent / Active) MECHANICAL SPECIFICATIONS Dimensions (H x W x D) Net Weight Gross Weight Transport Dimensions (H x W x D) Operating position Position in which devices transported PROTECT
W/SPECTO-000K70/00 350 VA / 200 W 700 VA / 400 W 367 x 118 x 125 mm 5,05 kg 5,35 kg 150 x 125 x 390 mm Vertical or horizontal Horizontal Short circuit protection - Fuse 5 x 20 mm 5 A / 250 V AC Surge Protection Electronic short-circuit and overload protection Overvoltage Protection and against reverse battery module connection Battery overcurrent - Automotive Fuse type UNIVAL 19 mm 40 A
Input over current protection Output over current protection DC over current (external battery input) ACCESSORY AND EXTRA FUNCTIONS Power supply connection Output connection (number and type of sockets ) Signalling CERTIFICATION Declarations Standards
screw terminals; max. 4 mm2 (cable) screw terminals; max. 4 mm2 (cable) Acoustic and optical CE PN-EN 62040-1:2009, PN-EN 62040-2:2008
INSTALLATION OF BATTERY PACKS To UPS can be connected battery modules (12 V lead–acid batteries) with total capacity up to 150 Ah CONNECTING THE CAR BATTERY Protected loads could be powered from lead-acid 12 V car battery with capacity up to 150 Ah. The connections should be made as per the wiring diagram, with conductors with a minimum section of 4 mm2.
POWER SUPPLY UNIT
PARAMETRY FRONT, BACKTECHNICZNE AND BOTTOM PANEL INPUT
OUTPUT
BATTERY
L PE N
L PE N
+ TVSS -
+
3
1 SPECLINE
4
5
2
-
CAR BATTERY 1) Main switch 2) Signalling diode 3) Mounting holders 4) Input fuse socket T 5 A 250 V. 5) UNIVAL battery fuseL 19 mm 40 A. 6) Mechanical elements for fastening leads in casing's lead ducts
6 EVER Sp. z o.o. ul. Wołczyńska 19, 60-003 Poznań, Poland tel. +48 61 6500 400, fax +48 61 6510 927, e-mail:
[email protected]