Preview only show first 10 pages with watermark. For full document please download

Datallnk/alllance Rack Enclosure

   EMBED


Share

Transcript

DATALlNK/ALLlANCE RACK ENCLOSURE A VERSAT/LE HOST S/TE MODEM MOUNT/NG SYSTEM FOR HOUS/NG MODEMS FROM 300 TO 9600 BPS AND BEYOND ~ SP 011_246-5364 DF 061 _234-7606 1':1 O M PATI BLE WITH DATA UN K ANO ALU ANCE 1:11 RACK M OUNT MODEM S l he Dat aJi n k/All ian ce (Ol X/Al X) Rack is a multiple modem mounting encl osu re fo r housing up to eight Data link and A lli ance modem s. lhe modem s may be intermixed within t he rack to alJow vari ous speeds and connecti on to b ot h leased lines and/orthe di al-u p network . MUlTIPLE POWER TRA NSFORM ERS l he Dl X/A LX Rac k supp lies low vo ltage AC pawe r, RS-232C/ D mating con necto rs, and t ele ph one line (onnect ions to each modem cardoM ultiple powe r t ransf ormers provide fa ult tolerance to powe r transf orme r fa i lures w it hin the rack. Each power transfo rmer supp li es powe r to two modem ca rds within t he rack. In the event a power transforme r f ails on Jy two modem cards w ill be inope rable, the rema ining six modems w ill continue to f unction. A powe r ON /OFF switch is access ible from t he rack frant pan el and a pr im ary f use protects th e rack from an elect rical short circuito In ad ditio n, t he power t ransf orm er's second ary w indings are protected by pico-fuses located on t he rac k-m ount modem cards. The p ower t ransfo rmer assemb ly is modular and is removable from the fro nt of the enclosu re. An optiona l - 48 VOC powe r supply is ava ilab te fo r Teko Central Office environm ents. Addi t ion ally, 22 0 VAC operation is avai lab le for intern ational app licati ons. CO M PUES WITH ElA EQUIP M ENT CABI N ET SPECI FICATION S The OLX/ALX Rack d imension s comply w ith El A specif icat ions f or mounting in a 19" w id e cabin et. Rac k adapte rs allow mounti ng in a standard 23" telephone equipme nt cab inet. The rack occup ies 10.5 inches of verti ca l ca bi net spaci ng. Bot h t he t op and b ottom of t he enctos ure are slotted fo r proper ve ntilat ion. A f ront p anel locking bar secures t he installed modems. ACCO MM ODATES LEASED-U NE AN O DIA L-UP TERMINATIONS Both dial-u p and leased-line con necti ons are accom modat ed by t h e OLX/ALX Rack Enct os ure. Th e st andard rack configurati on supports two Am phe nol-type 25-pair co nnectors. The con nect or pinouts are simi lar to t hose offe red bya USOC RJ-26X st yle te rminat ion. One con necto r is provided fo r diat -up (an d di al backup) access while t he other is avai labt e f or pr ivate line te rmi nations. l he dial-up connector acco m modates Tip and Ring, PR and PC, and MI and M IC connect ions. For dial-u p use the conf iguration is compati b le w ith most dial-up security ca llback systems. lhe teased- tine connector accommodates transmit and receive pa irs as well as t he dial b ackup receive tine f or 2-c all dial appl ic ations. OPTI ON CA RO S PROVIDE MO DULAR TELE PHON E UNE TER M INATI ONS For ftexibility, the OLX/ALX Rack is ava il able with t wo option ca rds fo r t ermin ation of t elephone circuits. Both the teased and dial-u p m ultiline te rmination con nect ors can be broken ou t ;nt o individual line terminations. lhe Dial U ne Modular Jack Card breaks out the dial-up connector into eight individ uat RJ-45 type, 8-pin connector jacks, wi t h a ninth 6-p in jack provided for a test line. l he leased Une Breakout Ca rd breaks out the teased-line connect or into 4-wi re, sc rewdown, barrier st rips fo r t he leased-line co nnection, and eight 6-pin modu ta r j acks for t he rece ive l ine dial bac k-up connections. A ninth 6-pin jack is atso provided for a second t est line (used fo r rece ive data in a 2-ca ll di at backu p mode). TEST / BU SY O PTI ON A Test/B usy Option Card Is availa b le with t he DLX/ALX Rack to alJ ow t he user t o b usy out di al-u p te lepho ne tin es from t he rack's front pane l. In addition, a test capabitity is provided to all ow a test lin e(s) to be ro uted to one of any of t he eig ht modems insta l led in the rack . l he test tines are spa re te lep hone lines connected into the rac k encl osu re. Upon suspicion of a fautty tine, a use r may rou te t he test tines to the ai ling ci rcui t t o verify t he lin e faiture, and to all ow cont in ued com m unication unt il t he defective l in e is rep aired. DATALlNK/ALLlANCE RACK ENCLOSURE A VERSAT/LE HOST S/TE MODEM MOUNT/NG SYSTEM FOR HOUS/NG MODEMS FROM 300 TO 9600 BPS ANO BEYOND FEATURES • Compatib le w it h Data link and Alli ance rackmount modems • Mu ltip le power transformers provide fa ult to lerance • Comp li es w it h ElA equipment cab inet specificatio ns • Accommodat e5 both lea5ed an d d ia l-up telepho ne lin es • Option cards provide modula r t eleph one line terminations • Test / Busy option provide5 te5t and busy-out capabi lit ies TECH NICA L 5PECIF ICATI ON5 O RDERI NG INF OR MATI O N Co mpatibility Data li nk 2400, 4800, 9600, and 9600FT rack·mount m odems, AII;ance 9600FT, V.32, V.32M, V.32/14.4, V.32/14.4M rackmaunt modems. Modem types may be intermixed w ith limitations ElA spedficati ons for 19·inch wide telephone equ ipment cab inet; can be easi ly adapted to fit 23-inch cabinet Capacity Up to eight modems Interface DTE: RS-232C1D 08-25 fema le (Qnnector for each modem Diallines: 50-p in male (onnector, RJ-26X compatible Leased lines: 50-pin male (onnector Modular connectors or screw-down barrier strips availab le on optional add-on card(s) 50-pin ma le diagnostic connector Requirements Line: Unconditioned four-wire or t wo-w ire leased, or two-wire switched lines (one or two per slot) Power: 101 to 132 VAe, 60 Hz ± 5% (-48 voe model also ava il ab le; 187 to 264 VOC) (220 VAC model also available 187 to 264 VAC) Power Co nsumption 21 watts (empty rack) Heat Dissipation 72 BTUlhr. (empty rack) Enviro nment A m bient temperature: o to 50 °C (32 to 122 ° F) Sto rage temperature: - 20 to 70 ° C (- 4 to 158° F) Relative h umid ity: 10 to 95% at 24°C (75 ° F) noncondensing Physica l Speci ficatio ns W idth : 19 inches (48.2 cm) Height: 10.5 inches (26.7 cm) Oepth: 10.75 inches (27 .3 cm) We ight: apprex. 15 pounds (7 kg) ~:::. :xJ.!!!!!~ Model No. 1608-01 1608-02 1638-02 Length NA NA NA Descript ion DLX/ALX Rack Enc1 osure, 117 VAC DLX/ALX Rack Enc1 osure, - 48 VAC Oata link Rack Enc losure, 220 VAC, BABT 5500-01 550 1-01 5502-01 5503-01 5507-01 NA NA NA NA NA Dial Line Modular Jack Ca rd Leased Li ne Breakout Ca rd Test/Busy Card 23 Inch Rack Adapters Blank Panel Set, 4 ea. 5600-01 -02 -03 7' 14 25 Cable, 50-pin connector to 50-wiresfor connection f rom DL Rack dial or leased-line connector to punch-down 5601-01 -02 -03 7' 14 25 Cable, 50-pin to 50-p in, RJ-26X compat ible with MI and MIC connections. Used for dia I or leased-line connectors. A li pins wired. 5602-01 -02 -03 7' 14 25 Cab le, 50-pin to 50-p in, RJ-21X compatible. Tip and Ring wired on ly. Used for dial-up connection. 5603-01 -02 -03 5604-01 -02 -03 5605-01 -02 -03 5606-01 -02 -03 7' 14 25 ea ble, 50-pin to SO-p in, RJ-26X compatib le. Used for dial-up connection. MI and Mie are not wired. 7' 14 25 Cable, 6-pin to Spade Tips for connection frem Leased Line Breakout Card to screw-down ter mi na l blocks. 7' 14 25 Cable, 6-p in to 6-pin modu lar fo r connect ion from Leased Line Breakout Card to RJ-l1 connection block. 7' 14 25 Cab le, 8-pin to 6-p in mod ul ar fo r connect ion frem Dial Li ne Modular Jack Card to RJ- 11 co nn ect ion block. 7' 14 25 Cable, 8-pin to 8-pin mod ular f or connection frem Dia l Line Modul ar Jack Card to RJ-45 connection block. 7' Cab le, Spade Tip to Spade Tip fo r connection frem Leased Li ne Breakout Card to screw-down te rminal blocks . block (e.g., 66B b lock). 5607-01 -02 -03 5608-01 Specifications subject to change without notice; confirm when ordering. n.,",""",,, ". """~"O. "'OO,,~,. Ca ll toll free (BOa) 473-6745. In Maryland (301) 921-8600. TWX 710-828-0522 . FAX (301) 921-8376 Penril DataComm LTD, Unit 02, Grahon Way, West Ham Industrial Estate, 8asingstoke, Hampshire, RG22 6HY, England Phone: 01 1-44-256-817-199. TLX: 851-858-326. FAX: 01 1-44-256-817-204 Penril DataComm Asia, 71F Wang Kee Bui lding, 34-37 Connaught Road, Central, Hong Kong • Phone: (852) 846-3100f(852) 846-3119 . FAX (852) 810-0478 10K 9f92 CP