Automotive Energy & Power Analysis Aerospace Tr a n s p o r t a t i o n G e n e r a l Te s t & M e a s u r e m e n t
Dataloggers D SERIES
Dataloggers for Industrial Uses Affordable Portable and Benchtop Models
For less demanding industrial applications we offer the D220, D820, D900 and D7000 series dataloggers. With flexible and isolated analog and pulse / logic inputs, these unique instruments pack a lot of power into amazingly small and inexpensive chassis.
Key Features
The D7000 is the top model in this series, with modular signal conditioners and incredible expandability. The D900 is the fastest among the SMALL models, which include the D900, D820 and D220. It features 8 high speed channels.
n n Stand-alone operation
The D820 features 20 isolated analog inputs - and you can add expansion terminals to increase your channel count in blocks of 20 ... all the way up to 200 channels. The D220 is the smallest and least expensive within the series, with 10 isolated analog input channels and sample rates up to 100 S/s/ch (when storing to RAM). All four excellent models feature the same easy user interface, offer a built-in color display, and Windows software for connection to your computer.
n n Very small D220, D820 and D900 models n n Desktop style D7000 model with modular conditioners n n High-speed capturing to internal RAM n n Easy connection to your Windows computer via USB 2.0 or Ethernet interfaces n n Plug in a USB stick and capture to it n n Isolated analog inputs n n Pulse/logic inputs and Alarm outputs n n Continuous or triggered recording modes n n Built to last
Online Information
http://www.dewamerica.com/Products/Dataloggers
1
Dataloggers D series
D7000 Overview
The D7000 is a powerful “building block data acquisition system.” The unique design is expandable from a single input module to 10 of them - each up to 10 channels to create a 100 channel system. In addition you can have the solid state drive module and pulse/logic module, for really 12 modules in all. Better yet you can connect up to five D7000s together with the SYNC cables and multiply your channel count 500%! n n Expandable from 4 to 100 channels - up to 10 analog input modules can be added even when the solid state HDD and pulse/logic modules are added n n Real ISOLATED inputs with 16-bit resolution n n Modules for voltage, high speed voltage, multi-type inputs, pulse/logic inputs, and more n n Alarm outputs and sync ports standard n n Removable display - locate it meters away via simple CAT6 cable (or have no display at all) n n Remote control via USB or ethernet - both are included n n Includes Windows software for remote control and data transfer/conversion
ALARM module (included)
2
Up to 10 modules can be installed (any combination is possible)
SSD solid state drive (optional - 64 GB)
Mainframe of the D7000 (display is optional and removable)
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D7000 Optional / Removable Display Even the display is modular - you can remove it completely, or locate it many feet away using a CAT5 cable. In fact, the display is an option ordered separately from the mainframe. If you have multiple systems synched together you may only want one display, for example.
D7000 Expansion
Sync up to 5 Systems Directly When you connect the sync cables from one D700 to the next, the first one automatically becomes the master. Connect up to four slave units and make a system with up to 560 channels. Triggering will be automatically passed from the master to all of the slaves, for truly synchronized measurement. A computer can be added, but it is not necessary - the master D700 can control all of the slaves. In this mode, only one D7-DISP display is needed!
Network up to 10 Systems In this case, the SYNC cables are not used - perhaps because the systems are too far apart from each other, or because you want to use more than 5 systems. Simply connect them all to the same computer via ethernet, using a switch or hub, and the standard Windows software will control up to ten D7000 systems, allowing more than 1000 channels to be acquired on the computer!
3
Dataloggers D SERIES
If you have the display, you can mount it dirctly onto the mainframe ... or remove it and connect it via a CAT5 ethernet cable. In this way you can use the screen from many feet away, and everything comes through the CAT5 cable: the display image, touchscreen interface, and power for the screen and its backlight. This is a great convenience.
D7000 Modules
Dataloggers D series
You can connect up to 10 input modules to each D7000 mainframe. In addition to those user-selectable modules, the ALARM output module is standard with the mainframe. Then you can add the SSD module, which provides a 64 GB solid state hard drive.But then you can STILL add 10 more modules! Add any combination of the modules shown below:
D7-V-10 Voltage Module
D7-M-10 Multi Module
D7-HS4-V High-Speed V
n n Medium Voltage inputs
n n Low Voltage /Thermocouple inputs
n n 10 channels
n n 10 channels
n n High Speed Medium Voltage inputs
n n 1 s/h to 1 kS/s max sample rate
n n 1 s/h to 100 S/s max sample rate
n n 16-bit resolution
n n 16-bit resolution
n n Ranges: 100mV to 100V FS, and 1-5V F.S.
n n Voltage ranges: 20mV to 50V F.S., and 1-5V F.S.
n n 2 MS of built-in RAM memory
n n T/C: K, J, E, T, R, S, B, N, W
n n Isolated inputs (unbalanced)
n n RTD: Pt100, Pt1000
n n M3 screw terminal input connectors
n n 2 MS of built-in RAM memory n n Isolated inputs (balanced)
n n 4 channels n n 1 s/h to 1 MS/s max sample rate n n 16-bit resolution n n Ranges: 100mV to 100V F.S., and 1-5V F.S. n n 2 MS of built-in RAM memory n n Isolated inputs (unbalanced) n n BNC input connectors
n n M3 screw terminal input connectors
D7-HV High-Voltage
D7-DCB Bridge Module
D7-CHA Accel. Module
n n High Voltage inputs
n n Strain / V / resistance
n n 2 channels
n n 4 channels
n n Accelerometers: IEPE and CHARGE sensors (selectable)
n n 1 s/h to 1 MS/s max sample rate
n n 1 S/h to 1 MS/s sample rates (20 kHz bandwidth)
n n 1 S/s to 1 MS/s max sample rate n n Selectable input coupling
n n Strain modes: 4 wire full bridge, 6 wire full bridge (with remote sense), 3 or 4 or 5 wire 1/2 bridge
n n High-pass and low-pass filters
n n 16-bit resolution n n Ranges: 2 V to 1000 V F.S. n n Input coupling DC, AC, DC-RMS, AC-RMS n n 2 MS of built-in RAM memory n n Isolated inputs (unbalanced) n n 1 MΩ input impedance n n Withstand 2300VAC up to 1 minute n n BNC input connectors
4
n n Gages from 50 Ω to 10 kΩ n n DCV Excitation: 1, 2, 2.5, 5, 10 V
n n Anti-aliasing filtering n n Charge sensors: 0.01 pC/(m/s2) to ~999 pC/(m/s2)
n n Constant current excitation
n n IEPE sensors: 0.01 mV/(m/s2) to ~ 999 mV/(m/s2)
n n Auto-balance and shunt cal
n n IEPE sensor power: 4/8 mA
n n 16-bit resolution, TEDS
n n 16-bit resolution, TEDS
n n DSUB9 input connectors
n n BNC (IEPE) and 10-32 (charge) connector for each channel
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D7-DCO Output Module
D7-POWER Module
n n Logic / Pulse inputs
n n Coming early 2014
n n Coming later 2014
n n 16 channels
n n Analog output module
n n For power measurements
n n Logic mode: up to 1 M S/s
n n 8 channels
n n Pulse mode: up to 10 kS/s
n n 100 kS/s/ch max output rate
n n Isolated Voltage and Current inputs
n n Bi-level signal, up to 24V
n n ±1, 2, 5, 10 V/F.S.
n n Selectable Logic or Pulse mode
n n Can generate DC, Sine wave, Triangle wave, Ramp wave, Pulse wave, or replay recorded data, or create arbitrary waveform
n n Logic: Signal pattern n n Pulse: Counting in Instant, Accumulating, Rotation (max. 15 million count) n n Common ground inputs n n DIN connectors
n n Output accuracy: ±0.25% of F.S.
Dataloggers D SERIES
D7-LP Logic/Pulse Module
n n More information will be available closer to the introduction time n n Picture above is only figurative n n Can be added to any existing D7000 system when this module becomes available
n n 16-bit resolution n n Selectable filtering / channel n n ±10 mA/ch max. current (±40 mA/ module) n n SMA connectors
The D7000 could be configured with as few as one D7 series module -- or up to 10 modules. The ALARM module is already included and does not count against the 10 modules that can be added. Also, the D7-SSD module (64 GB solid state HDD) can be added, and does not count against your 10 modules!
5
D7000 Specifications Main system Number of modules Max Input channels
Up to 10 modules can be added
Display module specifications
112 analog channels per D7000
Model number
D7-DISP
Outputs: Trigger, busy, alarms (10 channels) *3 ,
Display device
5.7 in TFT color LCD monitor (640x480 px)
I/O Signal type
Contact (relay), open collector, voltage
Operating methods
Touch screen and cursor keys
Trigger/alarm functions
Trigger Trigger Trigger Trigger
action: start or stop recording repeat: automatic rearm on/off selectable source: Signal value, alarm, external, time/date logic: OR and AND conditions based on signal level
Touch screen type
Capacitive type, compatilble with finger or touch pen
Language selection
English, French, German, Chinese, Korean, Japanese
Screen saver
Selectable on/off and delay time, from 10s to 60m
Trigger
detection: *5
Displayed information
YT waveforms with or without digital values, XY
Connection cable
LAN cable (CAT5 type), up to 10 m
Standard accessories
Bracket for slanted mount, connection cable (40 cm / 15 in.), grounding cable and required screws
Dimensions
~ 187 x 35 x 199 mm (~7.36 x 1.37 x 7.83 in.)
Weight
~ 530 g (1.16 lbs)
*2
rising, falling, window in/out,
Logic *4
high/low,
Pulse *4 rising, falling, window in/out Pretrigger: definable number of samples *6 Alarm outputs: 10 channels Calculation functions
Add, subtract, multiply, divide any two channels (10 S/s max). Statistical: Average, peak, min, max (both real time and replay) *7
*15
*16
Search function
Search for analog signal levels, logic signal pattern, pulse signal level or alarm point within the captured data
Display range
Move to start, center or end of the data, trigger point, or specified time (absolute or relative)
Model number
D7-SSD
Annotation function
Add up to 31 characters of text per channel
Device type
Solid state disk (SSD), 2.5” internal HDD
Message, marker
Message: record up to 8 messages before or during capture Marker: recorded upon trigger, alarm, or power failure
Capacity
Power resume
Automatic resumption after power failure during data capture *8
Interface to PC
Ethernet (10-Base-Tx), USB 2.0 (high speed)
Network function
Web server, FTP server, FTP client, NTP client, DHCP client
USB drive mode
File transfer from internal RAM memory via USB
Data storage
Built-in: 2 MS RAM per D7 module External: SD card (supports SDHC to 32 GB), optional SSD drive
*9
(approximately 64 GB of space) *10 Note: each data file is limited to 2 GB Data saving functions
Data files: internal RAM, built-in FLASH, SD memory, SSD *10 Auto-save: available for the built-in RAM - auto-copies data to the built-in flash, SD, or SSD media Ring capture: Saves the last values continuously (black box mode), selectable from 10 kS to 2 MS *10 *11 During data capture: Two window display mode, hot-swapping SD media, saving data between cursors Auto-backup: Back-up data to SD, SSD, FTP at 1, 2, 6, 12, 24 hour intervals (or never)
Channel scaling
*10
Apply engineering units to channels Analog channels: 2 point scaling (y = mx + b) Temperature: 2-point scaling (zero offset) Pulse count: 2-point scaling (gain)
SSD module specifications Sampling speed
~ 64 GB (each file can be up to 2 GB maximum) *17
With 1 - 2 modules: 1 MS/s maximum With 3 - 4 modules: 500 kS/s maximum With 5 - 10 modules: 200 kS/s maximum
Dimensions
~49 x 136 x 160 mm (~1.92 x 5.35 x 6.29 in.)
Weight
~ 770 g (1.7 lbs.)
Options & accessories Input/output cables
B-513 2 meters, pigtails
Humidity sensor
B-530 2m cables for signal and power
Synchronization cable
B-559 1 m, sync between two D7000s
Logic input rpobe set
RIC-10 4 channels, cable with alligator clips and IC clips
BNC-BNC input cable
RIC-112 1.5m, BNC to BNC, non-isolated 500 V max.
BAN-BNC input cable
RIC-113 1.5m, banana to BNC, non-isolated, 500 V max.
ALL-BNC input cable
RIC-114 1.5m, alligator to BNC, non-isolated, 500 V max.
BNC-BNC iso input cable
RIC-142 1.5m, BNC to BNC, isolated, CAT II, max 1000V
BAN-BNC iso input cable
RIC-143 1.5m, banana to BNC, isolated, CAT II 600 V max.
Alligator clip (small)
RIC-144 compatible with RIC-143, CAT II, 300V/15A max.
Alligator clip (medium)
RIC-145 compatible with RIC-143, CAT II, 1000V/32A max.
Clip, grabber
RIC-146 compatible with RIC-143, CAT II, 1000V/1A max.
*12
Synchronization
Start and trigger
Clock accuracy
±0.002% (@ 23°C) (monthly deviation ~50 s)
Operating environment
0 to 45°C, 5 to 85% RH (non-condensing)
Power input
100 to 240 VAC, 50/60 Hz Consumption: ~85 VA
Standard accessories
Quick Guide, CD-ROM with manual and software, AC power cable
Dimensions
Mainframe: 193 x 141 x 160 mm (7.6 x 5.5 x 6.29 in.) Alarm output terminal: 30 x 136 x 145 mm (1.18 x 5.35 x 5.7 in.)
Weight
Mainframe: ~ 2 kg (4.4 lbs) Alarm output terminal: ~ 350 g (0.77 lbs)
Weight
1.1 kg (approx., excluding AC adapter and battery)
Notes: *1 *2 *3 *4 *5
Software specifications
6
Screen can be locked, and requires password to unlock
Inputs: Start/stop, Trigger, External sampling, auto-balance
I/O Signals
Dataloggers D series
Operation lock *1
Software name
GL-Connect
Supported OS
Windows 7 (32/64) (not starter edition), WIndows XP
Functions
Control the D7000, real time data capture, replay data, data format conversion
Mutiple system control
Up to 10 D7000s can be controlled at once
Captured data
Data is captured on the D7000 hardware in real time, and can be transferred to the computer afterwards. Data cannot be streamed to the computer in real time
Data display
YT waveforms with digital values, X-Y graph, cursor information, capture condition, alarm information
File operation
Converts binary data to CSV format (specific period, all data in one file. or multiple files)
*12
Warning function
Send e-mail to the specified address when the alarms occur
Statistical calculation
Capturing data: max, min, peak, or average Replaying data: max, min, peak, ave, or RMS, in between cursors
*13 *14
Search function
Level: specific level in any channel Alarm: alarm within any channel Time: beginning, center, end of the data, trigger point, specific time (abs, relative), specific number
*6 *7 *8
*9 *10 *11
*15 *16 *17
Excluding the function or SSD module The input/output cable B-513 is required for connecting the signal. The auto-balance signal and the busy signal output are used in the DCB strain module The alarm signals are output on the terminal block attached to the mainframe as a standard accessory Available on the Logic/Pulse module Method of detection: Voltage/Temp module: the alarm is detected in the sample interval when the interval is shorter than 5 seconds. The alarm is detected every 5 seconds when the sample interval is longer than 5 seconds Other modules: the alarm is detected every 1 ms when the sample interval is shorter than 1 ms. The alarm is detected in the sample interval when the sampling interval is longer than 5 seconds. The alarm is detected in the sample interval when the sample interval is set between 2 ms and 5 seconds. The alarm is detected every 5 seconds when the sample interval is lonter than 5 seconds. Available when the captured data is saved ot the built-in RAM The result of real-time calculation is displayed in the digital display mode When the captured data desintation is set to the built-in RAM, the captured data is not maintained atter a power failure. The built-in flash or an SD memory card may be damaged by a power failure if it is writing data at the time. The file is closed automatically every minute during data capture as a protection method. The USB drive mode is activated via a hard switch on the mainframe. SD memory cards are not included - please provide them separately. When data capture destination is anything other than the built-in RAM, 1/3 of the available space on the device is reserved when data capture is begun, and the sample rate is limited to 100 S/s. The sync cable (B-559) is required when this function is used. When systems are synchronized, the Windows Software is required to be used. SP2 or higher service pack must be installed Data that is being captured to either the built-in RAM or SSD cannot also be saved to the PC in real time, but it can be transferred after data capture is complete. Most operations can be selected by both the touchscreen and the keys When the display modules is mounted at an angle using the included bracket, the CAT5 ethernet cable must be used to connect it to the mainframe. The sample rate of the D7000 is limited to the fastest sample rate of the slowest module that is connected to the system.
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D7-V-10 module specifications
Measurement accuracy (23°C±5°C) *1
Voltage ±0.1% of F.S.
Number of channels
10 channels / module
Input connector type
M3 screw type terminal
Input configuration
All channels insulated, simultaneous sampling, unbalanced input
Type
Range
Accuracy
Sampling interval
1, 2, 5, 10 ,20, 50, 100, 125, 200, 250, 500 msec, 1, 2, 5, 10, 20, 30 sec, 1, 2, 5, 10, 20, 30 min, 1 hour
R/S
Max sample rate
1 kS/s/ch (1 ms sampling interval)
Built-in RAM
2 million data points (2 MS)
0<=TS <=100 100<=TS <=300 R :3R:00
= 20 pC ±0.25% of FS [sensor sensitivity] x [setting range] >= 200 mV
A/D converter
Sequential comparison system, 16-bit resolution (Effective resolution: Approx. ±Range 1/40,000)
Temperature coefficient
Gain: ±0.01% of full scale/°C Zero point: ±0.02% of full scale/°C
Input resistance
100 kΩ ±5%
Sensor power
22 V ±10%, and 4 mA / 8 mA ±20%
Max. input (charge)
50,000 pC
Maximum input voltage
Input terminal (+) / input terminal (-) interval: 25 V p-p Input terminal (-) / input terminal (-) interval: 25 V p-p Input terminal (-) / GND interval: 25 V p-p
Withstand voltage
Input terminal (+) / input terminal (-) interval: 300 V p-p for 1 minute Input terminal (-) / GND interval: 300V p-p for 1 minute
Insulation resistance
Input terminal (-) / GND interval: 50 MΩ or more @500 VDC
Common mode rejection
80 dB or more (50/60 Hz signal source 300 Ω or less)
S/N (noise)
48 dB or more (± at short)
Frequency Response Charge sensors IEPE sensors
1.5 Hz to 45 kHz 1 Hz to 45 kHz
Filter High-pass Low-pass Anti-aliasing
OFF, 0.15, 1 and 10 Hz OFF, line (1.5 Hz), 3, 6, 10, 30, 50, 60, 100, 300, 500 Hz and 1, 3, 5, 10 kHz @ -30 dB/Q On / Off selectable
Internal gage resistance
120 or 350 Ω @ 1/4 and 1/2 bridge modes Note: at 120Ω, excitation of 1, 2 and 2.5V are available
TEDS compliance
Conforms to IEEE 1451.4 Class 2, Template 33. Includes read-out and auto-sensor data
Excitation voltage
DC: 1, 2, 2.5, 5, and 10 V Note: 5 and 10V only available @ 350 Ω
External dimensions [W×D×H] (approximate)
49.2 × 136 × 160 mm (not including protruding parts)
Constant current supply
0.1 to 20 mA selectable (10V max supply)
Weight
850 g (1.87 lbs)
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D7-LP logic/pulse module specifications
D7-HV High-Voltage
16 channels / module
Input connectors
Dedicated connector (4 channels for 1 group) Group A (CH1 to 4), Group B (CH5 to 8), Group C (CH9 to 12), Group D (CH13 to 16)
Input configuration
Non-isolated, all channels simultaneous sampling
Highest sample rate
Logic: 1 MS/s (1 µs interval) Pulse mode: 10 kS/s (100 µs interval)
Built-in RAM
2 million data points (2 MS)
Functions
Logic, Pulse The maximum use of the Logic function is 7 modules (112 ch). The maximum use of the Pulse function is 2 modules (32 ch). The maximum number of connections for each type of module to the mainframe is 10 (112 channels max.)
Pulse mode
Rotation / accumulating / instant
Rotation mode
Function: Counts the pulses (@ the sample rate), and converts them to RPM Span: 50, 50, 5000, 50k, 500k, 5M, 50M, 500M PRM/F.S.
Accumulating mode
Function: Displays the number of pulses accumulated for every sample interval from the beginning of the recording Span: 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S.
Instant mode
Function: Displays the pulse count for every sampling interval. The pulse count is reset for every sampling interval. Span: 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S.
Input specifications Input voltage range Input signal Threshold level Hysteresis
0 to +24 V (One line ground input) No-voltage contact (a contact, b contact, NO, NC), Open collector, voltage input Approx. +2.5 V Approx. 0.5 V (approx. +2.5 - approx. 3 V)
Max. input frequency
1 MHz
Max. number of counts
15 MC (15 million) based on 24-bit ADC
Filter
OFF, ON (50 Hz -3 dB)
External dimensions [W×D×H] (approximate)
49.2 × 136 × 160 mm (not including protruding parts)
Weight
700 g (1.54 lbs)
D7-DCO output module specifications
D7-M-10 Multi Module
D7-DCB Module
Number of channels
8 channels / module
Output terminals
SMA connector
Output configuration
All channels common ground
Sampling rate
100 kS/s/ch max (100 µs interval)
Output types
Data types Off Data file (Recorded data in the module to be output, Simple arbitrary waveform *2) DC, Sine wave, Traiangle wave, Ramp wave, Pulse wave Hardware output sources Data modules whose signals can be output: Voltage module (D7-V-10) Voltage/Temperature module (D7-M-10) High speed voltage module (D7-HSV-4) High voltage module (D7-HV-2) DC Strain module (D7-DCB) Output Conditions The sample interval is 10 μs or more While the waveform is output from the output module, the data measured in the other amplifier module can be recorded. Not possible to output the temperature and humidity data *2: Using the GL-Wave Editor supplied with the GL-Connection, the CSV waveform data can be generated arbitrarily * Microsoft EXCEL (Office 2003 or later) must be installed.
Output range
±1, 2, 5, 10 V/F.S.
Output accuracy (23°C±5°C) *1
±0.25% of F.S.
D/A converter
Resolution: 16-bit (Effective ability: Approximate ± range 1/20,000)
Temperature coefficient
Gain: ±0.01% of F.S./°C Zero: ±0.02% of F.S./°C
Allowable load resistance
1 kΩ or more
Max. output current
±10 mA/ch But TOTAL output current per module must be ±40 mA or less
Output impedance
1 Ω or less
S/N (noise)
48 dB or more (at OV output)
Filter (low-pass filter)
OFF, Line (1.5 Hz), 5 Hz, 50 Hz, 500 Hz, 5 kHz, 50 kHz *This is a smoothing filter to reduce noise from the D/A converter.
External dimensions [W×D×H] (approximate)
49.2 × 136 × 160 mm (not including protruding parts)
Weight
770 g (1.69 lbs)
D7-HS4-V High-Speed V
D7-CHA Module
Note *1 At least 30 minutes after turning on the power, sampling 1 sec, Filter Line, GND connection
9
Dataloggers D SERIES
D7-V-10 Voltage Module
Number of channels
D900 Overview Dataloggers D series
8 sets of BNC inputs for analog signals
Screw terminal behind each BNC for thermocouple connection
User interface no more complicated than a mobile phone
Bright 5.7” color display with multiple display modes
Chassis ground reference
Display can show your data in strip chart mode (Y-T), or X-Y, or numeric form.
DC power input jack Logic/pulse connector, plus alarms and trigger (inputs and outputs)
Screw terminal pair located behind each BNC for thermocouple connection
Power on/off switch (not shown - located on the right side panel)
Ventilation (both sides)
5V output for humidity sensor (optional)
(Top panel) USB 2.0 jack for connecting your USB memory stick (thumb drive)
Do not block the ventilation holes Ethernet and USB 2.0 interface jacks for computer connection
10
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D900 Features VOLTAGE TEMPERATURE HUMIDITY TRIGGER INPUT
Key Features ◙◙
±20 mV to ±500V on BNC connectors
◙◙ Thermocouples (J, K, T, E, R, S, B, N, W) (M3 screw terminal) ◙◙
0 to 100% (requires optional B-530 sensor)
◙◙ 1 Trigger input ◙◙ 4 channels (counting, RPM, inst. mode) ◙◙ 4 channels of pulse or logic inputs (selectable as a bank)
COUNTING / RPM
8 Fast Input Channels The inputs are simultaneously sampled with 16-bit A/D converters. You can set the sample rate anywhere from 1 S/minute/ch to 100 kS/s/ch (10 µs interval) when capturing to the internal RAM. Or you can select to capture to a USB stick that you plug in, at rates from 1 S/minute/ch to 1 kS/s/ch (1 ms interval). Most signals are input via the insulated BNC connectors, while the thermocouples are connected via the M3 screw terminal connectors. Thermocouple cables diameters up to 0.32 can be used.
Great GUI / Display The D900 features a brilliant 5.7” diagonal color display that serves as the user interface. You can show your data in these formats: n n Waveforms + digital values n n Enlarged waveforms n n Digital values + calculation results n n X-Y graph Buttons to the right of the screen complete the GUI, which is no more complicated to operate than the average mobile phone. You can run the display at high speeds if needed: up to 10 ms/division. At the other extreme you can run the display as slowly as 24 hours/division! The free running display allows you to monitor your data right on the screen, even when you’re not recording it. And because waveforms are displayed on each setup screen, you can even change your settings while viewing the data.
D900 data logger
High Voltage Capable The wide 500 V range allows 240 VAC power supply voltage waveform measurements. Using voltage, current AND a logic input allows simultaneous measurement of a test article’s power supply voltage, current and sequential control of various points.
11
Dataloggers D SERIES
LOGIC / PULSE
D900 Specifcations Dataloggers D series
Main system Analog input channels
8
External I/O channels
Trigger input (1 channel), Logic input (4 channels) or Pulse input (4 channels) Alarm output (4 channels)
Sample rate (interval)
1 S/m to 100 kS/s (10 µs)
Time/division
10 ms/div to 24 hours/div
Timer functions
Date and time, daily cycle, hourly cycle
Withstand voltage:
Between 1 minute Between 1 minute
Thermocouple accuracy* 8
Type: R / S:
Meas range: 0°C ≤ TS ≤100°C 100°C < TS ≤300°C R:300°C < TS ≤1600°C S:300°C < TS ≤1760°C
Accuracy: ±7.0°C ±5.0°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +3.0°C)
B:
400°C ≤ TS ≤600°C 600°C < TS ≤1820°C
±5.5°C ±(0.05% of rdg +3.0°C)
K:
-200°C ≤ TS ≤ -100°C -100°C < TS ≤ 1370°C
±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C)
E:
-200°C ≤ TS ≤ -100°C -100°C < TS ≤ 800°C
±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C)
T:
-200°C ≤ TS ≤-100°C -100°C < TS ≤400°C
±(0.1% of rdg +2.5°C) ±(0.1% of rdg +1.5°C)
J:
-200°C ≤ TS ≤-100°C -100°C < TS ≤ 100°C 100°C < TS ≤ 1100°C
±3.7°C ±2.7°C ±(0.05% of rdg +2.0°C)
N:
0°C ≤ TS ≤ 1300°C
±(0.1% of rdg +2.0°C)
W:
0°C ≤ TS ≤ 2000°C
±(0.1% of rdg +2.5°C)
Trigger input Trigger types
Start: Data capture starts on trigger Stop: Data capture stops on trigger
Trigger conditions
Start: Off, Input signal level (analog, logic/pulse), External* 1
Trigger combinations
Input signal level: Level OR, Level AND, Edge OR, Edge AND
Trigger modes
H (Rising), L (Falling), Window In* 2 , Window Out* 2
Alarm function Alarm functions
Rising, Falling, Window In* 2 , Window Out* 2
Alarm output
Number of channels: 4, Open collector output (5V, 10 kΩ pull-up resistance)
Pulse input RPM mode
50 to 20 M RPM/F.S. (in steps of 1, 2, or 5)
Count mode
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Inst mode
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
General calculations* 4 :
@ 23°C±5°C, after 30 minute warm-up time. Filter : Line GND : connected
Calculation functions
Statistical Average, Peak, Maximum, Minimum, RMS (2 calculations can be set simultaneously)
PC interface
Ethernet (10BASE-T/100BASE-TX), USB (High Speed supported) provided as standard
Ethernet functions
Web server, FTP server, NTP client
Control software specifications OS compatibility
USB functions
USB drive mode (File transfer and deletion from internal RAM memory)
Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions)
Software functions
D900 control, real-time data capture, data conversion to Excel & text
Internal memory
One million data points / Internal flash memory:Approx. 256 MB
Remote setup
Amplifier, data capture, trigger settings, alarm settings, and more
External memory
USB memory slot (High speed supported) USB memory slot (High speed supported) USB memory slot (High speed supported)* 5
Display information
Analog waveforms, logic waveforms, pulse waveforms, digital values
Data capture
Display screens
Waveforms + digital values, enlarged waveforms, digital values + calculation results, X-Y
Real-time data: Binary: Sampling speed: 10 μs to 60 s CSV: Sampling speed: 10 ms to 60 s
Data conversion
Data between cursors, or all data
Display hardware
5.7” diagonal color LCD TFT display
2-screen mode
Simultaneous display of real-time data and recorded data (history)
Withstand voltage
Between each input channel and GND: 1000 V p-p for one minute, between input terminals: 1000 Vp-p for one minute
Statistical display
Maximum, minimum, and average values
Power supply
Options and accessories
AC power input
100 to 240 VAC, 50 to 60 Hz, external AC/DC adapter is included
Battery pack*6
B-517
DC power input
8.5 to 24 VDC
Logic alarm cable
B-513, 2 meters
Battery power
Two batteries can be installed (optional)
DC power input cable
B-514, 2 meters
Humidity sensor *9
B-530, 3 meters
Safety voltage probe
RIC-141, 1:1 input/output, 42 pF
BNC to BNC cable
RIC-112, 1.5 meters
Power consumption
42 VA (when operating and charging batery with AC power)
Mechanical Dimensions W x H x D
232 x 150 x 80 mm (approx)
BNC to banana plug cable
RIC-113, 1.5 meters
Weight
1.1 kg (approx., excluding AC adapter and battery)
BNC - alligator clip cable
RIC-114, 1.5 meters
Operating environment
0 to 40°C, 5 to 85% R.H. (15 to 35°C when using batteries)
Rod-shaped K-type thermocouple
RIC-410, 1.1 meters
Vibration conditions
Equivalent to automobile parts Type 1 Category A classification
K-type thermocouple for static surfaces
RIC-420, 1.1 meters
L-shaped K-type thermocouple for static surfaces
RIC-430, 1.1 meters
Input specifications
12
Accuracy conditions:
input channel terminals and GND terminal: at 1000 V peak-to-peak input channel terminals: at 1000 V peak-to-peak
Input terminals
Voltage: insulated BNC (8) Temperature: M3 screw terminals (8)
A/D subsystem
16-bit ADCs (14-bit effective) Simultaneous sampling all analog channels
Isolation
500V
Input ranges, voltage
20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50, 100, 200, 500 V F.S., 1-5 V F.S.
Thermocouple types
Thermocouples : K, J, E, T, R, S, B, N, W (WRe5-26)
Humdity input
0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option)
Input filter
Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel)
Voltage accuracy* 8
±0.25% of F.S.
Maximum permissible input voltage
Between input channel + and - terminals: 20 mV to 1 V: ±30 VDC; 2 V to 500 V : ±500 VDC Between input channel terminals: 60 V peak-to-peak Between input channel terminals and GND: 60 V peak-to-peak
Notes: *1 Logic alarm cable (B-513) is required. *2 Cannot be set for logic input *3 Maximum input frequency: 50 kHz, maximum number of counts: 15 M C *4 In real time or when Between Cursors has been specified (during Replay) *5 1 file = 2 Gbytes (depends on the USB memory stick used) *6 Please install two battery packs. *7 Connections are made to both the BNC terminal and M3 screw terminal for the same channel. *8 Thermocouple diameters T:0.32, others:0.65 *9 Operating temperature range: -25 to +80°C
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
Wide Range of Sample Rates and Durations Long-term data can be captured directly to built-in 256-MB flash memory or to an external USB memory stick at sampling intervals of from 1 ms to 1 min. For high-speed sampling at intervals faster than 1 ms, choose the internal RAM and you can sample as fast as 100 kS/s/ch! That’s a 10 µs sample interval, suitable for very high speed data. Not very many data loggers in the world can sample this fast! Sampling Interval (Sample Rate)
10 s
100 µs (10 kS/s) 1m 40s
500 µs (2 kS/s)
1 ms (1 kS/s)
10 ms (100 S/s)
100 ms (10 S/s)
1 s (1 S/s)
8m 20 s
16m 20s
2 h 40s
1d 3h
11d 13h
Internal FLASH (256 MB)
X
X
X
11 hours
4 days
49 days
493 days
Ext. USB stick (512 MB)
X
X
X
22 hours
8 days
98 days
986 days
Note: The USB stick must be a standard model without advanced features such as fingerprint recognition. Recording times shown above are approximate.
Press the MENU button, then set your INPUT TYPE for each channel independently. Or use the AL channel and set ALL of the channels to be the same with one selection!
High speed sampling - even during temperature measurement Even when you’re recording temperature channels, you can use the highest recording speeds. This is not possible on the slower models D820 and D220. But there are no limitations with the D900: it’s built for speed, regardless of the input type.
Supports USB memory devices, Easy connection to PC via USB or Ethernet
When recording VOLTAGE you can set the range for each channel independently from the selections shown above.
Captured data can be saved directly to USB memory sticks - just plug one in, and then select it as your capture destination. In addition, you can connect your D900 to your Windows computer via a standard USB cable - and even transfer data in real-time! The D900 can even emulate an external USB drive for fast and convenient transfer of large data files to your PC. If you choose to connect via ethernet, you can monitor your data using a browser via the standard web server function. Open up a browser and point it to the IP address of the D900 - and you’re in business, remotely controlling and monitoring the unit from your desktop easier than ever before.
When recording thermocouples, you can select from among the sensor types shown above.
13
Dataloggers D SERIES
Internal RAM (up to 1 M samples)
10 µs (100 kS/s)
D820 Overview Dataloggers D series
20 sets of screw terminal inputs for analog signals
Additional terminal behind each +/- pair, for thermocouple connection
User interface no more complicated than a mobile phone
Bright 5.7” color display with multiple display modes
Display can show your data in strip chart mode (Y-T), or X-Y, or numeric form.
All dimensions in mm, tolerance ±5 mm
14
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D820 Features VOLTAGE TEMPERATURE HUMIDITY TRIGGER INPUT COUNTING / RPM
◙◙
Modular expansion up to 200 analog channels!
◙◙ All channels multifunction: voltage, thermocouples, RTDs, etc. ◙◙ Thermocouples (J, K, T, E, R, S, B, N, W) (M3 screw terminal) ◙◙
Humdity: 0 to 100% (requires optional B-530 sensor)
◙◙ 1 Trigger input ◙◙ 4 channels (counting, RPM, instant and counting modes) ◙◙ 4 channels of pulse or logic inputs (selectable as a bank)
Expandable from 20 to 200 Channels The standard D820 includes a terminal block on its top surface with 20 sets of inputs. However, you can replace this block with the B-537 expansion terminal, and then daisy-chain the standard block, plus up to TEN MORE blocks (option B-538) to expand the D820 from 20 channels to 40, 60, 80, 100, 120, 140, 160, 180 or even 200 channels! When you are using the included Windows remote control software, you can control and manage up to 500 channels or ten D820 systems (whichever comes first). So for example, you could remotely control five D820s with 80 channels each PLUS five more D820s with 20 channels each. As long as the channel count doesn’t exceed 500, and the D820 unit count doesn’t exceed ten, any combination is possible.
Great GUI / Display The D820 features a bright clear 5.7” color TFT monitor (VGA: 640 x 480 dots). Makes it easy to read data in waveform or digital form and to check your measurement parameter settings. You can show your data in these formats: n n Waveforms + digital values n n Enlarged waveforms n n Digital values + calculation results n n Past and present data SPLIT SCREEN display Buttons to the right of the screen complete the GUI, which is no more complicated to operate than the average mobile phone. The free running display allows you to monitor your data right on the screen, even when you’re not recording it. And because waveforms are displayed on each setup screen, you can even change your settings while viewing the data.
D820 data logger
High Voltage Capable The wide 500 V range allows 240 VAC power supply voltage waveform measurements. Using voltage, current AND a logic input allows simultaneous measurement of a test article’s power supply voltage, current and sequential control of various points.
15
Dataloggers D SERIES
LOGIC / PULSE
Key Features
D820 Specifications Main system Analog input channels
Dataloggers D series
External I/O channels
Voltage Temperature
20 ch, Expandable up to 200 ch by unit of 20 ch
*1
Sample rates / intervals
Time/division
1 x Trigger or Sampling input 4 x Logic or Pulse inputs 4 x Alarm outputs Up to 100 S/s/ch Intervals: 10 ms to 1 h (voltage only at rates from 10 ms to 50 ms) Rates are limited by number of channels installed Plus external rate control 1 sec to 24 hours/division
Trigger functions Actions Sources Combinations Conditions
Alarm functions Detecting method Condition
Alarm outputs * 1 Pulse input function * 1 Count mode Instant count mode RPM count mode
Max. input pulse rate
Start or stop capturing data based on trigger Start: Off, Input signal, Alarm, External * 1 , Clock, Week or Time Stop: Off, Input signal, Alarm, External * 1 , Clock, Week or Time OR or AND condition at the level of signal or edge of signal Analog: Rising, Falling, Window-in, Window-out Pulse: Rising, Falling, Window-in, Window-out Logic: Rising, Falling
Humidity
0, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, and 1-5 V/F.S. Thermocouple: K, J, E, T, R, S, B, N, and W (WRe5-26) Resistance Temperature Detectors (RTDs): Pt100, JPt100(JIS), Pt1000(IEC751) 0 to 100% (using humidity sensor (B-530 optional), the D820 can supply power to maximum one B-530 sensor)
Filter
Off, 2, 5, 10, 20, 40 (moving average in selected number)
Humdity input
0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option)
Input filter
Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel)
Accuracy, voltage* 4
0.1 % of F.S.
Accuracy, temperature* 4
Type: R / S:
Meas range: 0°C ≤ TS ≤100°C 100°C < TS ≤300°C R:300°C < TS ≤1600°C S:300°C < TS ≤1760°C
Accuracy: ±5.2°C ±3.0°C ±(0.05% of rdg +2.0°C) ±(0.05% of rdg +2.0°C)
B:
400°C ≤ TS ≤600°C 600°C < TS ≤1820°C
±3.5°C ±(0.05% of rdg +2.0°C)
K:
-200°C ≤ TS ≤ -100°C -100°C < TS ≤ 1370°C
±(0.05% of rdg +2.0°C) ±(0.05% of rdg +1.0°C)
E:
-200°C ≤ TS ≤ -100°C -100°C < TS ≤ 800°C
±(0.05% of rdg +2.0°C) ±(0.05% of rdg +1.0°C)
T:
-200°C ≤ TS ≤-100°C -100°C < TS ≤400°C
±(0.1 % of reading + 1.5 °C) ± (0.1 % of reading + 0.5 °C)
J:
-200°C ≤ TS ≤-100°C -100°C < TS ≤ 100°C 100°C < TS ≤ 1100°C
±2.7°C ±1.7°C ±(0.05% of rdg +1.0°C)
N:
0°C ≤ TS ≤ 1300°C
±(0.1% of rdg +1.0°C)
W:
0°C ≤ TS ≤ 2000°C
±(0.1% of rdg +1.5°C)
Level or edge of signal Analog: Rising, Falling, Window-in, Window-out Pulse: Rising, Falling, Window-in, Window-out Logic: Rising, Falling 4 channels, Output type: Open collector (pulled-up to 5 V by resistor 10 kΩ) Accumulating the number of pulses from the start of measurement Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S. Counting the number of pulses per sampling interval Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S. Counting the number of pulses per second and then it is converted to RPM Range: 50 rpm, 500 rpm, 5 krpm, 50 krpm, 500 krpm, 5 Mrpm, 50 Mrpm, 500 Mrpm /F.S. 50 k pulses/sec or 50k counts per sampling interval (16 bits counter is used)
Reference Junction Compensation (R.J.C.): ±0.5 °C RTD
Measurement range
Measurement accuracy
Addition, Subtraction, Multiplication and Division for analog input Select two calculations from Average, Peak, Max., Min., RMS
Pt100
-200 °C to 850 °C (FS = 1050 °C)
±1°C
Search function
Search for analog signal levels, values of logic or pulse or alarm point in captured data
JPt100
-200 °C to 500 °C (FS = 700 °C)
±0.8 °C
Interface to PC
Ethernet (10 BASE-T/100 BASE-TX), USB (Full speed)
PT1000
Storage device
Built-in Flash memory (2 giga-bytes), USB memory device * 2
-200 °C to 500 °C (FS = 700 °C)
-200 °C to 500 °C (FS = 700 °C)
Calculation functions Between channels Statistical
Data saving function Captured data Others
Direct saving of data into built-in Flash memory or USB memory device Setting conditions, Screen copy
Ring capturing mode
Function: ON/OFF, Number of capturing point: 1000 to 2000000 (size of the capture data will be limited to 1/3 of available memory when in Ring Mode)
USB device mode
USB Memory emulation mode (Transfer or delete files in built-in memory)
Channel scaling function
Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output).
Maximum input voltage
Between + / - terminal: 60 V p-p Between channels: 60 V p-p Between channel / GND: 60 V p-p
Withstand voltage
Between channels: 350 V p-p (1 minute) Between channel(-)/ GND: 350 V p-p (1 minute)
Control software specifications OS compatibility
Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions)
Software functions
Up to 10 systems can be controlled Controls real-time data capture, data conversion to Excel & text
Captured data
Transfers data in real-time (in binary or CSV format), saved data in D820 or the USB memory
Displayed information
Analog waveforms, Logic waveforms, Pulse waveforms, Digital values
5.7 inch TFT color LCD (VGA: 640 x 480 dots) Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital
Display modes
Y-T waveforms, Digital values, Report, X-Y graph (specified period of data, data reply only)
Warning functions
Sends E-mail to the specified address when the alarms occur
Operating environment
0 to 45 °C, 5 to 85 %RH (When operating with battery pack 0 to 40 °C, charging battery 15°C to 35 °C)
Report function
Creates the daily or monthly report automatically (can also export directly to Excel)
Power source
AC adapter (100 to 240 V, 50/60 Hz), DC power (8.5 to 24 V DC, max. 26.4 V) * 10 , Battery pack * 3
Options and accessories
Power consumption
32 VA or lower (when operating with AC adapter, displaying LCD, charging battery pack)
Channel extension terminal base kit (one required for adding expansion units)
B-537, including cable
Dimensions W x H x D (approx.)
232 x 152 x 50 mm 9.13 x 5.98 x 1.96 in.
20 channel expansion unit
B-538, includes fixing plate
Logic alarm cable
B-513 (2 meters, flying leads)
Weight (approx)
900 g (Excluding AC adapter and battery pack) 1.98 lbs (Excluding AC adapter and battery pack)
DC power input cable
B-514 (2 meters, flying leads)
Humidity sensor
B-530, 3 meters, includes plug to 5V power on D820
Display Size Formats
Mechanical
Input specifications
16
Input ranges
Input terminals
M3 screw terminals
Input configuration
Photo-MOS-relay scan, all channels isolated and balanced
A/D type
Delta-sigma type, 16-bits (effective resolution 1/40,000 of meaurement range FS)
Notes *1 Logic alarm cable (B-513) option is required. *2 Size of the USB memory device is unlimited. Maximum file size is limited to 2GB. *3 DC drive cable (B-514) or battery pack (B-517) option is required. *4 Subject to the following conditions: Room Temperature is 23°C ±5°C, 30 minute warm-up time, sample rate of 1s on 20 channels max., GND terminal is connected to ground *5 Operating environment: -25°C to +85°C max.
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D820 Details
Wide Range of Sample Rates Sample rates up to 100S/s/ch (10 ms interval) can be selected, depending on the number of channels being recorded. Here is how it works: Sampling Interval (ms)
10
20
50
100
200
500
1000
Number of channels
1
2
5
10
20
50
100
2000 200
Voltage measurements
√
√
√
√
√
√
√
√
Temperature measurements
X
X
X
√
√
√
√
√
Note: for humidty measurements, the 0-1V range and scaling functions are used to display your results directly in % RH. Sampling rate limitations are same as those for voltage measurement.
The 2GB Flash Memory enables secure long term data measurement without using an external storage device. Data is retained even when power is turned off because flash memory is used. Also supports popular USB memory sticks for external storage. The D820 saves measured data directly to USB memory sticks. USB memory sticks can be replaced during measurement without data loss.
Capturing time Sampling Interval (ms)
*3
*4
To the built-in FLASH memory (recording time in DAYS) To a 512 MB USB memory stick (recording time in DAYS)
(20 Analog channels being used.) 10
50
100
200
29
72
89
101
7
18
22
25
500
1,000
10,000
253
506
5,068
64
129
1,294
Note: for humidty measurements, the 0-1V range and scaling functions are used to display your results directly in % RH. Sampling rate limitations are same as those for voltage measurement. Notes: *3 Estimate of recording times are approximate *4 The sample rate is limited by the number of channels in use. 10 ms = 1 channel; 50 ms = 5 channels, etc. *5 Standard USB memory devices without high-end functions such as fingerprint recognition are required
Ring memory function This is the so-called “black box” mode, where the memory is a circular buffer that stores the most recent information. You can activate this mode when either internal memory or external memory is used. Captured data size in ring memory mode is limited to 1/3 of available memory.
It’s Alarming! The D820 features FOUR alarm outputs, which you can define to watch for various conditions being met. When it happens, the system will output the alarm, which you can connect to another system to play a sound, or activate a relay, etc. Note - Accessing the alarm signals requires the optional B-513 cable.
Isolated for your protection... The D820’s isolated input system ensures that your important signals are not corrupted by ground loops or crosstalk from other channels. Isolation is the best possible way to eliminating wiring and grounding concerns. The D820s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage.
Supports USB memory devices, Easy connection to PC via USB or Ethernet Captured data can be saved directly to USB memory sticks - just plug one in, and then select it as your capture destination. In addition, you can connect your D820 to your Windows computer via a standard USB cable - and even transfer data in real-time! The D820 can even emulate an external USB drive for fast and convenient transfer of large data files to your PC. If you choose to connect via ethernet, you can monitor your data using a browser via the standard web server function, or use FTP client-server functionality. NTP (network time protocol) is also supported when the D820 is connected to the LAN via the Ethernet port.
17
Dataloggers D SERIES
Built-in 2 GB Flash Memory for reliable long-term measurements
D220 Overview Dataloggers D series
10 sets of screw terminal inputs for analog signals
User interface no more complicated than a mobile phone
Bright 4.3” color display with multiple display modes
18
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
D220 Features VOLTAGE TEMPERATURE HUMIDITY TRIGGER INPUT
Key Features ◙◙
±20 mV to ±50V on screw terminal connectors
◙◙
Built-in 2 GB flash memory
◙◙
Ring buffer function
◙◙
Sample rates up to 100 S/s/ch (10 ms interval)
◙◙ 4 channels (counting, RPM, inst. mode) ◙◙ 4 channels of pulse or logic inputs (selectable as a bank)
COUNTING / RPM
Great GUI / Display The D220 features a great 4.3” color TFT display that serves as the user interface. You can show your data in these formats: n n Waveforms + digital values n n Enlarged waveforms n n Digital values + calculation results
Multifunction Analog Inputs The inputs are simultaneously sampled with 16-bit A/D converters. You can set the sample rate anywhere from 1 S/minute/ch to 100 kS/s/ch (10 µs interval) when capturing to the internal RAM. Or you can select to capture to a USB stick that you plug in, at rates from 1 S/minute/ch to 1 kS/s/ch (1 ms interval). Most signals are input via the insulated BNC connectors, while the thermocouples are connected via the M3 screw terminal connectors. Thermocouple cables diameters up to 0.32 can be used.
n n X-Y graph Buttons to the right of the screen complete the GUI, which is no more complicated to operate than the average mobile phone. You can run the display at high speeds if needed: up to 10 ms/division. At the other extreme you can run the display as slowly as 24 hours/division! The free running display allows you to monitor your data right on the screen, even when you’re not recording it. And because waveforms are displayed on each setup screen, you can even change your settings while viewing the data.
D220 data logger
19
Dataloggers D SERIES
LOGIC / PULSE
D220 Specifcations Dataloggers D series
Main system Analog input channels
10
External I/O channels
Trigger input (1 channel), Logic input (4 channels) or Pulse input (4 channels) Alarm output (4 channels)
Sample rate (interval)
1 S/m to 100 S/s (10 µs)
Time/division
10 ms/div to 24 hours/div
Timer functions
Date and time, daily cycle, hourly cycle
Withstand voltage:
Between 1 minute Between 1 minute
Thermocouple accuracy* 8
Type: R / S:
Meas range: 0°C ≤ TS ≤100°C 100°C < TS ≤300°C R:300°C < TS ≤1600°C S:300°C < TS ≤1760°C
Accuracy: ±7.0°C ±5.0°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +3.0°C)
B:
400°C ≤ TS ≤600°C 600°C < TS ≤1820°C
±5.5°C ±(0.05% of rdg +3.0°C)
K:
-200°C ≤ TS ≤ -100°C -100°C < TS ≤ 1370°C
±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C)
E:
-200°C ≤ TS ≤ -100°C -100°C < TS ≤ 800°C
±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C)
T:
-200°C ≤ TS ≤-100°C -100°C < TS ≤400°C
±(0.1% of rdg +2.5°C) ±(0.1% of rdg +1.5°C)
J:
-200°C ≤ TS ≤-100°C -100°C < TS ≤ 100°C 100°C < TS ≤ 1100°C
±3.7°C ±2.7°C ±(0.05% of rdg +2.0°C)
N:
0°C ≤ TS ≤ 1300°C
±(0.1% of rdg +2.0°C)
W:
0°C ≤ TS ≤ 2000°C
±(0.1% of rdg +2.5°C)
Trigger input Trigger types
Start: Data capture starts on trigger Stop: Data capture stops on trigger
Trigger conditions
Start: Off, Input signal level (analog, logic/pulse), External* 1
Trigger combinations
Input signal level: Level OR, Level AND, Edge OR, Edge AND
Trigger modes
H (Rising), L (Falling), Window In* 2 , Window Out* 2
Alarm function Alarm functions
Rising, Falling, Window In* 2 , Window Out* 2
Alarm output
Number of channels: 4, Open collector output (5V, 10 kΩ pull-up resistance)
Pulse input RPM mode
50 to 20 M RPM/F.S. (in steps of 1, 2, or 5)
Count mode
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Inst mode
50 to 20 M C/F.S. (in steps of 1, 2, or 5)
General
@ 23°C±5°C, after 30 minute warm-up time. Filter : Line GND : connected
Calculation functions
Statistical calculations* 4 : Average, Peak, Maximum, Minimum, RMS (2 calculations can be set simultaneously)
PC interface
Ethernet (10BASE-T/100BASE-TX), USB (High Speed supported) provided as standard
Ethernet functions
Web server, FTP server, NTP client
OS compatibility
USB functions
USB drive mode (File transfer and deletion from internal RAM memory)
Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions)
Software functions
D900 control, real-time data capture, data conversion to Excel & text
Internal memory
One million data points / Internal flash memory:Approx. 256 MB
Remote setup
Amplifier, data capture, trigger settings, alarm settings, and more
External memory
USB memory slot (High speed supported) USB memory slot (High speed supported) USB memory slot (High speed supported)* 5
Display information
Analog waveforms, logic waveforms, pulse waveforms, digital values
Data capture
Display screens
Waveforms + digital values, enlarged waveforms, digital values + calculation results, X-Y
Real-time data: Binary: Sampling speed: 10 μs to 60 s CSV: Sampling speed: 10 ms to 60 s
Data conversion
Data between cursors, or all data
Display hardware
5.7” diagonal color LCD TFT display
2-screen mode
Simultaneous display of real-time data and recorded data (history)
Withstand voltage
Between each input channel and GND: 1000 V p-p for one minute, between input terminals: 1000 Vp-p for one minute
Statistical display
Maximum, minimum, and average values
AC power input
100 to 240 VAC, 50 to 60 Hz, external AC/DC adapter is included
Battery pack*6
B-517
DC power input
8.5 to 24 VDC
Logic alarm cable
B-513, 2 meters
Battery power
Two batteries can be installed (optional)
DC power input cable
B-514, 2 meters
Power consumption
42 VA (when operating and charging batery with AC power)
Humidity sensor *9
B-530, 3 meters
Safety voltage probe
RIC-141, 1:1 input/output, 42 pF
BNC to BNC cable
RIC-112, 1.5 meters
BNC to banana plug cable
RIC-113, 1.5 meters
BNC - alligator clip cable
RIC-114, 1.5 meters
Rod-shaped K-type thermocouple
RIC-410, 1.1 meters
K-type thermocouple for static surfaces
RIC-420, 1.1 meters
L-shaped K-type thermocouple for static surfaces
RIC-430, 1.1 meters
Power supply
Mechanical Dimensions W x H x D
232 x 150 x 80 mm (approx)
Weight
1.1 kg (approx., excluding AC adapter and battery)
Operating environment
0 to 40°C, 5 to 85% R.H. (15 to 35°C when using batteries)
Vibration conditions
Equivalent to automobile parts Type 1 Category A classification
Input specifications
20
Accuracy conditions:
input channel terminals and GND terminal: at 1000 V peak-to-peak input channel terminals: at 1000 V peak-to-peak
Input terminals
Voltage: insulated BNC (8) Temperature: M3 screw terminals (8)
A/D subsystem
16-bit ADCs (14-bit effective) Simultaneous sampling all analog channels
Isolation
500V
Input ranges, voltage
20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50, 100, 200, 500 V F.S., 1-5 V F.S.
Thermocouple types
Thermocouples : K, J, E, T, R, S, B, N, W (WRe5-26)
Humdity input
0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option)
Input filter
Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel)
Voltage accuracy* 8
±0.25% of F.S.
Maximum permissible input voltage
Between input channel + and - terminals: 20 mV to 1 V: ±30 VDC; 2 V to 500 V : ±500 VDC Between input channel terminals: 60 V peak-to-peak Between input channel terminals and GND: 60 V peak-to-peak
Control software specifications
Options and accessories
Notes: *1 Logic alarm cable (B-513) is required. *2 Cannot be set for logic input *3 Maximum input frequency: 50 kHz, maximum number of counts: 15 M C *4 In real time or when Between Cursors has been specified (during Replay) *5 1 file = 2 Gbytes (depends on the USB memory stick used) *6 Please install two battery packs. *7 Connections are made to both the BNC terminal and M3 screw terminal for the same channel. *8 Thermocouple diameters T:0.32, others:0.65 *9 Operating temperature range: -25 to +80°C
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
Dataloggers D SERIES
21
Windows Software Included Dataloggers D series
Three measurement screens are provided for real time data display, during acquisition: • Y/T display • X-Y display • FFT display Them after you’re done recording, the REPLAY screen has a great ZOOM feature so you can examine areas of interest in greater detail.
Easy setup You can configure the most important parameters of the D900 using the Windows software, too. Functions like entering channels names are easier on the computer, of course, where you have a full size keyboard to work with.
More analysis capabilities Need even more analytical horsepower? Why not use DS-7 software! If you buy an LT license, you can import text format data files from the D900 and perform a wide range of analytical functions:
22
◙◙
Formula math, including trigonometry, algebra, boolean, and arithmetic
◙◙
Filtering - design your own IIR, FIR and FFT filters. Highpass, low-pass, band-pass, band-stop. Up to 10th order. Bessell, Butterworth, Chebychev
◙◙
Integration, double integration, differentiation, double integration, custom multi-sectional polynomials
◙◙
Array math processing and display in 2D and 3D modes
◙◙
Options available for power analysis, FRF, sine processing, sound level metering, order tracking...
More software functions The standard windows software provides these additional capabilities: ◙◙
Direct to Excel - eliminates time-consuming file conversion
◙◙
Search function - look for specific values within the data
◙◙
CSV batch file conversion - process multiple files at once
◙◙
Thumbnail display of captured files
◙◙
Ability to open text formatted data files in DS-7-LT or higher software, for advanced analysis functions
More FILE TRANSFER functions The standard windows software provides these additional capabilities: ◙◙
Web server/FTP server - Waveform display and D900 setup operations can be performed via a web browser. In addition, data files captured to the D900’s internal memory or to a USB memory stick can be transferred or deleted from PC.
◙◙
USB mode - When your D900 is connected to your PC via the USB interface, you can perform fast and easy data transfers from the internal memory to the PC.
◙◙
NTP client function - Connect the D900 to an NTP server via an Ethernet connection to synchronize D900 time with NTP server time at periodic intervals.
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/
Dataloggers D SERIES
23
Dataloggers D series
USA Headquarters Dewetron, Inc. 10 High Street, Suite K Wakefield, RI 02879 USA Phone +1 401-284-3750 (GMT-5) Toll-free: +1 877-431-5166 Fax: +1 401-284-3755
Regional Offices:
[email protected] www.dewamerica.com
Dewetron Midwest 2142 Pontiac Road Suite 104 Auburn Hills, MI 48326 Phone: +1 (248) 613-4706 (GMT-5) Dewetron West 23046 Avenida de la Carlota, Ste 600 Laguna Hills, CA 92653 Phone: +1 (949) 241-4815 (GMT-8) Dewetron Southeast 22 West Bryan St. #136 Savannah GA 31401 Phone: +1 (912) 344-6918 (GMT-5)
Sales Agents: We have sales agents located all over the USA, Canada, Mexico, Central America, and South America. Please contact DEWETRON to find your closest office, or visit our website to learn more: http://www.dewamerica.com/Contact/
DEWETRON, INC. • 10 High Street, Ste K • Wakefield•RI•02879•USA Tel (+1) 401-284-3750 • Fax (+1) 401-284-3755 • [email protected]
24
h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/