Preview only show first 10 pages with watermark. For full document please download

Dataloggers_brochure..

   EMBED


Share

Transcript

Automotive Energy & Power Analysis Aerospace Tr a n s p o r t a t i o n G e n e r a l Te s t & M e a s u r e m e n t Dataloggers D SERIES Dataloggers for Industrial Uses Affordable Portable and Benchtop Models For less demanding industrial applications we offer the D220, D820, D900 and D7000 series dataloggers. With flexible and isolated analog and pulse / logic inputs, these unique instruments pack a lot of power into amazingly small and inexpensive chassis. Key Features The D7000 is the top model in this series, with modular signal conditioners and incredible expandability. The D900 is the fastest among the SMALL models, which include the D900, D820 and D220. It features 8 high speed channels. n n Stand-alone operation The D820 features 20 isolated analog inputs - and you can add expansion terminals to increase your channel count in blocks of 20 ... all the way up to 200 channels. The D220 is the smallest and least expensive within the series, with 10 isolated analog input channels and sample rates up to 100 S/s/ch (when storing to RAM). All four excellent models feature the same easy user interface, offer a built-in color display, and Windows software for connection to your computer. n n Very small D220, D820 and D900 models n n Desktop style D7000 model with modular conditioners n n High-speed capturing to internal RAM n n Easy connection to your Windows computer via USB 2.0 or Ethernet interfaces n n Plug in a USB stick and capture to it n n Isolated analog inputs n n Pulse/logic inputs and Alarm outputs n n Continuous or triggered recording modes n n Built to last Online Information http://www.dewamerica.com/Products/Dataloggers 1 Dataloggers D series D7000 Overview The D7000 is a powerful “building block data acquisition system.” The unique design is expandable from a single input module to 10 of them - each up to 10 channels to create a 100 channel system. In addition you can have the solid state drive module and pulse/logic module, for really 12 modules in all. Better yet you can connect up to five D7000s together with the SYNC cables and multiply your channel count 500%! n n Expandable from 4 to 100 channels - up to 10 analog input modules can be added even when the solid state HDD and pulse/logic modules are added n n Real ISOLATED inputs with 16-bit resolution n n Modules for voltage, high speed voltage, multi-type inputs, pulse/logic inputs, and more n n Alarm outputs and sync ports standard n n Removable display - locate it meters away via simple CAT6 cable (or have no display at all) n n Remote control via USB or ethernet - both are included n n Includes Windows software for remote control and data transfer/conversion ALARM module (included) 2 Up to 10 modules can be installed (any combination is possible) SSD solid state drive (optional - 64 GB) Mainframe of the D7000 (display is optional and removable) h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D7000 Optional / Removable Display Even the display is modular - you can remove it completely, or locate it many feet away using a CAT5 cable. In fact, the display is an option ordered separately from the mainframe. If you have multiple systems synched together you may only want one display, for example. D7000 Expansion Sync up to 5 Systems Directly When you connect the sync cables from one D700 to the next, the first one automatically becomes the master. Connect up to four slave units and make a system with up to 560 channels. Triggering will be automatically passed from the master to all of the slaves, for truly synchronized measurement. A computer can be added, but it is not necessary - the master D700 can control all of the slaves. In this mode, only one D7-DISP display is needed! Network up to 10 Systems In this case, the SYNC cables are not used - perhaps because the systems are too far apart from each other, or because you want to use more than 5 systems. Simply connect them all to the same computer via ethernet, using a switch or hub, and the standard Windows software will control up to ten D7000 systems, allowing more than 1000 channels to be acquired on the computer! 3 Dataloggers D SERIES If you have the display, you can mount it dirctly onto the mainframe ... or remove it and connect it via a CAT5 ethernet cable. In this way you can use the screen from many feet away, and everything comes through the CAT5 cable: the display image, touchscreen interface, and power for the screen and its backlight. This is a great convenience. D7000 Modules Dataloggers D series You can connect up to 10 input modules to each D7000 mainframe. In addition to those user-selectable modules, the ALARM output module is standard with the mainframe. Then you can add the SSD module, which provides a 64 GB solid state hard drive.But then you can STILL add 10 more modules! Add any combination of the modules shown below: D7-V-10 Voltage Module D7-M-10 Multi Module D7-HS4-V High-Speed V n n Medium Voltage inputs n n Low Voltage /Thermocouple inputs n n 10 channels n n 10 channels n n High Speed Medium Voltage inputs n n 1 s/h to 1 kS/s max sample rate n n 1 s/h to 100 S/s max sample rate n n 16-bit resolution n n 16-bit resolution n n Ranges: 100mV to 100V FS, and 1-5V F.S. n n Voltage ranges: 20mV to 50V F.S., and 1-5V F.S. n n 2 MS of built-in RAM memory n n T/C: K, J, E, T, R, S, B, N, W n n Isolated inputs (unbalanced) n n RTD: Pt100, Pt1000 n n M3 screw terminal input connectors n n 2 MS of built-in RAM memory n n Isolated inputs (balanced) n n 4 channels n n 1 s/h to 1 MS/s max sample rate n n 16-bit resolution n n Ranges: 100mV to 100V F.S., and 1-5V F.S. n n 2 MS of built-in RAM memory n n Isolated inputs (unbalanced) n n BNC input connectors n n M3 screw terminal input connectors D7-HV High-Voltage D7-DCB Bridge Module D7-CHA Accel. Module n n High Voltage inputs n n Strain / V / resistance n n 2 channels n n 4 channels n n Accelerometers: IEPE and CHARGE sensors (selectable) n n 1 s/h to 1 MS/s max sample rate n n 1 S/h to 1 MS/s sample rates (20 kHz bandwidth) n n 1 S/s to 1 MS/s max sample rate n n Selectable input coupling n n Strain modes: 4 wire full bridge, 6 wire full bridge (with remote sense), 3 or 4 or 5 wire 1/2 bridge n n High-pass and low-pass filters n n 16-bit resolution n n Ranges: 2 V to 1000 V F.S. n n Input coupling DC, AC, DC-RMS, AC-RMS n n 2 MS of built-in RAM memory n n Isolated inputs (unbalanced) n n 1 MΩ input impedance n n Withstand 2300VAC up to 1 minute n n BNC input connectors 4 n n Gages from 50 Ω to 10 kΩ n n DCV Excitation: 1, 2, 2.5, 5, 10 V n n Anti-aliasing filtering n n Charge sensors: 0.01 pC/(m/s2) to ~999 pC/(m/s2) n n Constant current excitation n n IEPE sensors: 0.01 mV/(m/s2) to ~ 999 mV/(m/s2) n n Auto-balance and shunt cal n n IEPE sensor power: 4/8 mA n n 16-bit resolution, TEDS n n 16-bit resolution, TEDS n n DSUB9 input connectors n n BNC (IEPE) and 10-32 (charge) connector for each channel h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D7-DCO Output Module D7-POWER Module n n Logic / Pulse inputs n n Coming early 2014 n n Coming later 2014 n n 16 channels n n Analog output module n n For power measurements n n Logic mode: up to 1 M S/s n n 8 channels n n Pulse mode: up to 10 kS/s n n 100 kS/s/ch max output rate n n Isolated Voltage and Current inputs n n Bi-level signal, up to 24V n n ±1, 2, 5, 10 V/F.S. n n Selectable Logic or Pulse mode n n Can generate DC, Sine wave, Triangle wave, Ramp wave, Pulse wave, or replay recorded data, or create arbitrary waveform n n Logic: Signal pattern n n Pulse: Counting in Instant, Accumulating, Rotation (max. 15 million count) n n Common ground inputs n n DIN connectors n n Output accuracy: ±0.25% of F.S. Dataloggers D SERIES D7-LP Logic/Pulse Module n n More information will be available closer to the introduction time n n Picture above is only figurative n n Can be added to any existing D7000 system when this module becomes available n n 16-bit resolution n n Selectable filtering / channel n n ±10 mA/ch max. current (±40 mA/ module) n n SMA connectors The D7000 could be configured with as few as one D7 series module -- or up to 10 modules. The ALARM module is already included and does not count against the 10 modules that can be added. Also, the D7-SSD module (64 GB solid state HDD) can be added, and does not count against your 10 modules! 5 D7000 Specifications Main system Number of modules Max Input channels Up to 10 modules can be added Display module specifications 112 analog channels per D7000 Model number D7-DISP Outputs: Trigger, busy, alarms (10 channels) *3 , Display device 5.7 in TFT color LCD monitor (640x480 px) I/O Signal type Contact (relay), open collector, voltage Operating methods Touch screen and cursor keys Trigger/alarm functions Trigger Trigger Trigger Trigger action: start or stop recording repeat: automatic rearm on/off selectable source: Signal value, alarm, external, time/date logic: OR and AND conditions based on signal level Touch screen type Capacitive type, compatilble with finger or touch pen Language selection English, French, German, Chinese, Korean, Japanese Screen saver Selectable on/off and delay time, from 10s to 60m Trigger detection: *5 Displayed information YT waveforms with or without digital values, XY Connection cable LAN cable (CAT5 type), up to 10 m Standard accessories Bracket for slanted mount, connection cable (40 cm / 15 in.), grounding cable and required screws Dimensions ~ 187 x 35 x 199 mm (~7.36 x 1.37 x 7.83 in.) Weight ~ 530 g (1.16 lbs) *2 rising, falling, window in/out, Logic *4 high/low, Pulse *4 rising, falling, window in/out Pretrigger: definable number of samples *6 Alarm outputs: 10 channels Calculation functions Add, subtract, multiply, divide any two channels (10 S/s max). Statistical: Average, peak, min, max (both real time and replay) *7 *15 *16 Search function Search for analog signal levels, logic signal pattern, pulse signal level or alarm point within the captured data Display range Move to start, center or end of the data, trigger point, or specified time (absolute or relative) Model number D7-SSD Annotation function Add up to 31 characters of text per channel Device type Solid state disk (SSD), 2.5” internal HDD Message, marker Message: record up to 8 messages before or during capture Marker: recorded upon trigger, alarm, or power failure Capacity Power resume Automatic resumption after power failure during data capture *8 Interface to PC Ethernet (10-Base-Tx), USB 2.0 (high speed) Network function Web server, FTP server, FTP client, NTP client, DHCP client USB drive mode File transfer from internal RAM memory via USB Data storage Built-in: 2 MS RAM per D7 module External: SD card (supports SDHC to 32 GB), optional SSD drive *9 (approximately 64 GB of space) *10 Note: each data file is limited to 2 GB Data saving functions Data files: internal RAM, built-in FLASH, SD memory, SSD *10 Auto-save: available for the built-in RAM - auto-copies data to the built-in flash, SD, or SSD media Ring capture: Saves the last values continuously (black box mode), selectable from 10 kS to 2 MS *10 *11 During data capture: Two window display mode, hot-swapping SD media, saving data between cursors Auto-backup: Back-up data to SD, SSD, FTP at 1, 2, 6, 12, 24 hour intervals (or never) Channel scaling *10 Apply engineering units to channels Analog channels: 2 point scaling (y = mx + b) Temperature: 2-point scaling (zero offset) Pulse count: 2-point scaling (gain) SSD module specifications Sampling speed ~ 64 GB (each file can be up to 2 GB maximum) *17 With 1 - 2 modules: 1 MS/s maximum With 3 - 4 modules: 500 kS/s maximum With 5 - 10 modules: 200 kS/s maximum Dimensions ~49 x 136 x 160 mm (~1.92 x 5.35 x 6.29 in.) Weight ~ 770 g (1.7 lbs.) Options & accessories Input/output cables B-513 2 meters, pigtails Humidity sensor B-530 2m cables for signal and power Synchronization cable B-559 1 m, sync between two D7000s Logic input rpobe set RIC-10 4 channels, cable with alligator clips and IC clips BNC-BNC input cable RIC-112 1.5m, BNC to BNC, non-isolated 500 V max. BAN-BNC input cable RIC-113 1.5m, banana to BNC, non-isolated, 500 V max. ALL-BNC input cable RIC-114 1.5m, alligator to BNC, non-isolated, 500 V max. BNC-BNC iso input cable RIC-142 1.5m, BNC to BNC, isolated, CAT II, max 1000V BAN-BNC iso input cable RIC-143 1.5m, banana to BNC, isolated, CAT II 600 V max. Alligator clip (small) RIC-144 compatible with RIC-143, CAT II, 300V/15A max. Alligator clip (medium) RIC-145 compatible with RIC-143, CAT II, 1000V/32A max. Clip, grabber RIC-146 compatible with RIC-143, CAT II, 1000V/1A max. *12 Synchronization Start and trigger Clock accuracy ±0.002% (@ 23°C) (monthly deviation ~50 s) Operating environment 0 to 45°C, 5 to 85% RH (non-condensing) Power input 100 to 240 VAC, 50/60 Hz Consumption: ~85 VA Standard accessories Quick Guide, CD-ROM with manual and software, AC power cable Dimensions Mainframe: 193 x 141 x 160 mm (7.6 x 5.5 x 6.29 in.) Alarm output terminal: 30 x 136 x 145 mm (1.18 x 5.35 x 5.7 in.) Weight Mainframe: ~ 2 kg (4.4 lbs) Alarm output terminal: ~ 350 g (0.77 lbs) Weight 1.1 kg (approx., excluding AC adapter and battery) Notes: *1 *2 *3 *4 *5 Software specifications 6 Screen can be locked, and requires password to unlock Inputs: Start/stop, Trigger, External sampling, auto-balance I/O Signals Dataloggers D series Operation lock *1 Software name GL-Connect Supported OS Windows 7 (32/64) (not starter edition), WIndows XP Functions Control the D7000, real time data capture, replay data, data format conversion Mutiple system control Up to 10 D7000s can be controlled at once Captured data Data is captured on the D7000 hardware in real time, and can be transferred to the computer afterwards. Data cannot be streamed to the computer in real time Data display YT waveforms with digital values, X-Y graph, cursor information, capture condition, alarm information File operation Converts binary data to CSV format (specific period, all data in one file. or multiple files) *12 Warning function Send e-mail to the specified address when the alarms occur Statistical calculation Capturing data: max, min, peak, or average Replaying data: max, min, peak, ave, or RMS, in between cursors *13 *14 Search function Level: specific level in any channel Alarm: alarm within any channel Time: beginning, center, end of the data, trigger point, specific time (abs, relative), specific number *6 *7 *8 *9 *10 *11 *15 *16 *17 Excluding the function or SSD module The input/output cable B-513 is required for connecting the signal. The auto-balance signal and the busy signal output are used in the DCB strain module The alarm signals are output on the terminal block attached to the mainframe as a standard accessory Available on the Logic/Pulse module Method of detection: Voltage/Temp module: the alarm is detected in the sample interval when the interval is shorter than 5 seconds. The alarm is detected every 5 seconds when the sample interval is longer than 5 seconds Other modules: the alarm is detected every 1 ms when the sample interval is shorter than 1 ms. The alarm is detected in the sample interval when the sampling interval is longer than 5 seconds. The alarm is detected in the sample interval when the sample interval is set between 2 ms and 5 seconds. The alarm is detected every 5 seconds when the sample interval is lonter than 5 seconds. Available when the captured data is saved ot the built-in RAM The result of real-time calculation is displayed in the digital display mode When the captured data desintation is set to the built-in RAM, the captured data is not maintained atter a power failure. The built-in flash or an SD memory card may be damaged by a power failure if it is writing data at the time. The file is closed automatically every minute during data capture as a protection method. The USB drive mode is activated via a hard switch on the mainframe. SD memory cards are not included - please provide them separately. When data capture destination is anything other than the built-in RAM, 1/3 of the available space on the device is reserved when data capture is begun, and the sample rate is limited to 100 S/s. The sync cable (B-559) is required when this function is used. When systems are synchronized, the Windows Software is required to be used. SP2 or higher service pack must be installed Data that is being captured to either the built-in RAM or SSD cannot also be saved to the PC in real time, but it can be transferred after data capture is complete. Most operations can be selected by both the touchscreen and the keys When the display modules is mounted at an angle using the included bracket, the CAT5 ethernet cable must be used to connect it to the mainframe. The sample rate of the D7000 is limited to the fastest sample rate of the slowest module that is connected to the system. h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D7-V-10 module specifications Measurement accuracy (23°C±5°C) *1 Voltage ±0.1% of F.S. Number of channels 10 channels / module Input connector type M3 screw type terminal Input configuration All channels insulated, simultaneous sampling, unbalanced input Type Range Accuracy Sampling interval 1, 2, 5, 10 ,20, 50, 100, 125, 200, 250, 500 msec, 1, 2, 5, 10, 20, 30 sec, 1, 2, 5, 10, 20, 30 min, 1 hour R/S Max sample rate 1 kS/s/ch (1 ms sampling interval) Built-in RAM 2 million data points (2 MS) 0<=TS <=100 100<=TS <=300 R :3R:00= 20 pC ±0.25% of FS [sensor sensitivity] x [setting range] >= 200 mV A/D converter Sequential comparison system, 16-bit resolution (Effective resolution: Approx. ±Range 1/40,000) Temperature coefficient Gain: ±0.01% of full scale/°C Zero point: ±0.02% of full scale/°C Input resistance 100 kΩ ±5% Sensor power 22 V ±10%, and 4 mA / 8 mA ±20% Max. input (charge) 50,000 pC Maximum input voltage Input terminal (+) / input terminal (-) interval: 25 V p-p Input terminal (-) / input terminal (-) interval: 25 V p-p Input terminal (-) / GND interval: 25 V p-p Withstand voltage Input terminal (+) / input terminal (-) interval: 300 V p-p for 1 minute Input terminal (-) / GND interval: 300V p-p for 1 minute Insulation resistance Input terminal (-) / GND interval: 50 MΩ or more @500 VDC Common mode rejection 80 dB or more (50/60 Hz signal source 300 Ω or less) S/N (noise) 48 dB or more (± at short) Frequency Response Charge sensors IEPE sensors 1.5 Hz to 45 kHz 1 Hz to 45 kHz Filter High-pass Low-pass Anti-aliasing OFF, 0.15, 1 and 10 Hz OFF, line (1.5 Hz), 3, 6, 10, 30, 50, 60, 100, 300, 500 Hz and 1, 3, 5, 10 kHz @ -30 dB/Q On / Off selectable Internal gage resistance 120 or 350 Ω @ 1/4 and 1/2 bridge modes Note: at 120Ω, excitation of 1, 2 and 2.5V are available TEDS compliance Conforms to IEEE 1451.4 Class 2, Template 33. Includes read-out and auto-sensor data Excitation voltage DC: 1, 2, 2.5, 5, and 10 V Note: 5 and 10V only available @ 350 Ω External dimensions [W×D×H] (approximate) 49.2 × 136 × 160 mm (not including protruding parts) Constant current supply 0.1 to 20 mA selectable (10V max supply) Weight 850 g (1.87 lbs) h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D7-LP logic/pulse module specifications D7-HV High-Voltage 16 channels / module Input connectors Dedicated connector (4 channels for 1 group) Group A (CH1 to 4), Group B (CH5 to 8), Group C (CH9 to 12), Group D (CH13 to 16) Input configuration Non-isolated, all channels simultaneous sampling Highest sample rate Logic: 1 MS/s (1 µs interval) Pulse mode: 10 kS/s (100 µs interval) Built-in RAM 2 million data points (2 MS) Functions Logic, Pulse The maximum use of the Logic function is 7 modules (112 ch). The maximum use of the Pulse function is 2 modules (32 ch). The maximum number of connections for each type of module to the mainframe is 10 (112 channels max.) Pulse mode Rotation / accumulating / instant Rotation mode Function: Counts the pulses (@ the sample rate), and converts them to RPM Span: 50, 50, 5000, 50k, 500k, 5M, 50M, 500M PRM/F.S. Accumulating mode Function: Displays the number of pulses accumulated for every sample interval from the beginning of the recording Span: 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. Instant mode Function: Displays the pulse count for every sampling interval. The pulse count is reset for every sampling interval. Span: 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. Input specifications Input voltage range Input signal Threshold level Hysteresis 0 to +24 V (One line ground input) No-voltage contact (a contact, b contact, NO, NC), Open collector, voltage input Approx. +2.5 V Approx. 0.5 V (approx. +2.5 - approx. 3 V) Max. input frequency 1 MHz Max. number of counts 15 MC (15 million) based on 24-bit ADC Filter OFF, ON (50 Hz -3 dB) External dimensions [W×D×H] (approximate) 49.2 × 136 × 160 mm (not including protruding parts) Weight 700 g (1.54 lbs) D7-DCO output module specifications D7-M-10 Multi Module D7-DCB Module Number of channels 8 channels / module Output terminals SMA connector Output configuration All channels common ground Sampling rate 100 kS/s/ch max (100 µs interval) Output types Data types Off Data file (Recorded data in the module to be output, Simple arbitrary waveform *2) DC, Sine wave, Traiangle wave, Ramp wave, Pulse wave Hardware output sources Data modules whose signals can be output: Voltage module (D7-V-10) Voltage/Temperature module (D7-M-10) High speed voltage module (D7-HSV-4) High voltage module (D7-HV-2) DC Strain module (D7-DCB) Output Conditions The sample interval is 10 μs or more While the waveform is output from the output module, the data measured in the other amplifier module can be recorded. Not possible to output the temperature and humidity data *2: Using the GL-Wave Editor supplied with the GL-Connection, the CSV waveform data can be generated arbitrarily * Microsoft EXCEL (Office 2003 or later) must be installed. Output range ±1, 2, 5, 10 V/F.S. Output accuracy (23°C±5°C) *1 ±0.25% of F.S. D/A converter Resolution: 16-bit (Effective ability: Approximate ± range 1/20,000) Temperature coefficient Gain: ±0.01% of F.S./°C Zero: ±0.02% of F.S./°C Allowable load resistance 1 kΩ or more Max. output current ±10 mA/ch But TOTAL output current per module must be ±40 mA or less Output impedance 1 Ω or less S/N (noise) 48 dB or more (at OV output) Filter (low-pass filter) OFF, Line (1.5 Hz), 5 Hz, 50 Hz, 500 Hz, 5 kHz, 50 kHz *This is a smoothing filter to reduce noise from the D/A converter. External dimensions [W×D×H] (approximate) 49.2 × 136 × 160 mm (not including protruding parts) Weight 770 g (1.69 lbs) D7-HS4-V High-Speed V D7-CHA Module Note *1 At least 30 minutes after turning on the power, sampling 1 sec, Filter Line, GND connection 9 Dataloggers D SERIES D7-V-10 Voltage Module Number of channels D900 Overview Dataloggers D series 8 sets of BNC inputs for analog signals Screw terminal behind each BNC for thermocouple connection User interface no more complicated than a mobile phone Bright 5.7” color display with multiple display modes Chassis ground reference Display can show your data in strip chart mode (Y-T), or X-Y, or numeric form. DC power input jack Logic/pulse connector, plus alarms and trigger (inputs and outputs) Screw terminal pair located behind each BNC for thermocouple connection Power on/off switch (not shown - located on the right side panel) Ventilation (both sides) 5V output for humidity sensor (optional) (Top panel) USB 2.0 jack for connecting your USB memory stick (thumb drive) Do not block the ventilation holes Ethernet and USB 2.0 interface jacks for computer connection 10 h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D900 Features VOLTAGE TEMPERATURE HUMIDITY TRIGGER INPUT Key Features ◙◙ ±20 mV to ±500V on BNC connectors ◙◙ Thermocouples (J, K, T, E, R, S, B, N, W) (M3 screw terminal) ◙◙ 0 to 100% (requires optional B-530 sensor) ◙◙ 1 Trigger input ◙◙ 4 channels (counting, RPM, inst. mode) ◙◙ 4 channels of pulse or logic inputs (selectable as a bank) COUNTING / RPM 8 Fast Input Channels The inputs are simultaneously sampled with 16-bit A/D converters. You can set the sample rate anywhere from 1 S/minute/ch to 100 kS/s/ch (10 µs interval) when capturing to the internal RAM. Or you can select to capture to a USB stick that you plug in, at rates from 1 S/minute/ch to 1 kS/s/ch (1 ms interval). Most signals are input via the insulated BNC connectors, while the thermocouples are connected via the M3 screw terminal connectors. Thermocouple cables diameters up to 0.32 can be used. Great GUI / Display The D900 features a brilliant 5.7” diagonal color display that serves as the user interface. You can show your data in these formats: n n Waveforms + digital values n n Enlarged waveforms n n Digital values + calculation results n n X-Y graph Buttons to the right of the screen complete the GUI, which is no more complicated to operate than the average mobile phone. You can run the display at high speeds if needed: up to 10 ms/division. At the other extreme you can run the display as slowly as 24 hours/division! The free running display allows you to monitor your data right on the screen, even when you’re not recording it. And because waveforms are displayed on each setup screen, you can even change your settings while viewing the data. D900 data logger High Voltage Capable The wide 500 V range allows 240 VAC power supply voltage waveform measurements. Using voltage, current AND a logic input allows simultaneous measurement of a test article’s power supply voltage, current and sequential control of various points. 11 Dataloggers D SERIES LOGIC / PULSE D900 Specifcations Dataloggers D series Main system Analog input channels 8 External I/O channels Trigger input (1 channel), Logic input (4 channels) or Pulse input (4 channels) Alarm output (4 channels) Sample rate (interval) 1 S/m to 100 kS/s (10 µs) Time/division 10 ms/div to 24 hours/div Timer functions Date and time, daily cycle, hourly cycle Withstand voltage: Between 1 minute Between 1 minute Thermocouple accuracy* 8 Type: R / S: Meas range: 0°C ≤ TS ≤100°C 100°C < TS ≤300°C R:300°C < TS ≤1600°C S:300°C < TS ≤1760°C Accuracy: ±7.0°C ±5.0°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +3.0°C) B: 400°C ≤ TS ≤600°C 600°C < TS ≤1820°C ±5.5°C ±(0.05% of rdg +3.0°C) K: -200°C ≤ TS ≤ -100°C -100°C < TS ≤ 1370°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C) E: -200°C ≤ TS ≤ -100°C -100°C < TS ≤ 800°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C) T: -200°C ≤ TS ≤-100°C -100°C < TS ≤400°C ±(0.1% of rdg +2.5°C) ±(0.1% of rdg +1.5°C) J: -200°C ≤ TS ≤-100°C -100°C < TS ≤ 100°C 100°C < TS ≤ 1100°C ±3.7°C ±2.7°C ±(0.05% of rdg +2.0°C) N: 0°C ≤ TS ≤ 1300°C ±(0.1% of rdg +2.0°C) W: 0°C ≤ TS ≤ 2000°C ±(0.1% of rdg +2.5°C) Trigger input Trigger types Start: Data capture starts on trigger Stop: Data capture stops on trigger Trigger conditions Start: Off, Input signal level (analog, logic/pulse), External* 1 Trigger combinations Input signal level: Level OR, Level AND, Edge OR, Edge AND Trigger modes H (Rising), L (Falling), Window In* 2 , Window Out* 2 Alarm function Alarm functions Rising, Falling, Window In* 2 , Window Out* 2 Alarm output Number of channels: 4, Open collector output (5V, 10 kΩ pull-up resistance) Pulse input RPM mode 50 to 20 M RPM/F.S. (in steps of 1, 2, or 5) Count mode 50 to 20 M C/F.S. (in steps of 1, 2, or 5) Inst mode 50 to 20 M C/F.S. (in steps of 1, 2, or 5) General calculations* 4 : @ 23°C±5°C, after 30 minute warm-up time. Filter : Line GND : connected Calculation functions Statistical Average, Peak, Maximum, Minimum, RMS (2 calculations can be set simultaneously) PC interface Ethernet (10BASE-T/100BASE-TX), USB (High Speed supported) provided as standard Ethernet functions Web server, FTP server, NTP client Control software specifications OS compatibility USB functions USB drive mode (File transfer and deletion from internal RAM memory) Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions) Software functions D900 control, real-time data capture, data conversion to Excel & text Internal memory One million data points / Internal flash memory:Approx. 256 MB Remote setup Amplifier, data capture, trigger settings, alarm settings, and more External memory USB memory slot (High speed supported) USB memory slot (High speed supported) USB memory slot (High speed supported)* 5 Display information Analog waveforms, logic waveforms, pulse waveforms, digital values Data capture Display screens Waveforms + digital values, enlarged waveforms, digital values + calculation results, X-Y Real-time data: Binary: Sampling speed: 10 μs to 60 s CSV: Sampling speed: 10 ms to 60 s Data conversion Data between cursors, or all data Display hardware 5.7” diagonal color LCD TFT display 2-screen mode Simultaneous display of real-time data and recorded data (history) Withstand voltage Between each input channel and GND: 1000 V p-p for one minute, between input terminals: 1000 Vp-p for one minute Statistical display Maximum, minimum, and average values Power supply Options and accessories AC power input 100 to 240 VAC, 50 to 60 Hz, external AC/DC adapter is included Battery pack*6 B-517 DC power input 8.5 to 24 VDC Logic alarm cable B-513, 2 meters Battery power Two batteries can be installed (optional) DC power input cable B-514, 2 meters Humidity sensor *9 B-530, 3 meters Safety voltage probe RIC-141, 1:1 input/output, 42 pF BNC to BNC cable RIC-112, 1.5 meters Power consumption 42 VA (when operating and charging batery with AC power) Mechanical Dimensions W x H x D 232 x 150 x 80 mm (approx) BNC to banana plug cable RIC-113, 1.5 meters Weight 1.1 kg (approx., excluding AC adapter and battery) BNC - alligator clip cable RIC-114, 1.5 meters Operating environment 0 to 40°C, 5 to 85% R.H. (15 to 35°C when using batteries) Rod-shaped K-type thermocouple RIC-410, 1.1 meters Vibration conditions Equivalent to automobile parts Type 1 Category A classification K-type thermocouple for static surfaces RIC-420, 1.1 meters L-shaped K-type thermocouple for static surfaces RIC-430, 1.1 meters Input specifications 12 Accuracy conditions: input channel terminals and GND terminal: at 1000 V peak-to-peak input channel terminals: at 1000 V peak-to-peak Input terminals Voltage: insulated BNC (8) Temperature: M3 screw terminals (8) A/D subsystem 16-bit ADCs (14-bit effective) Simultaneous sampling all analog channels Isolation 500V Input ranges, voltage 20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50, 100, 200, 500 V F.S., 1-5 V F.S. Thermocouple types Thermocouples : K, J, E, T, R, S, B, N, W (WRe5-26) Humdity input 0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option) Input filter Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel) Voltage accuracy* 8 ±0.25% of F.S. Maximum permissible input voltage Between input channel + and - terminals: 20 mV to 1 V: ±30 VDC; 2 V to 500 V : ±500 VDC Between input channel terminals: 60 V peak-to-peak Between input channel terminals and GND: 60 V peak-to-peak Notes: *1 Logic alarm cable (B-513) is required. *2 Cannot be set for logic input *3 Maximum input frequency: 50 kHz, maximum number of counts: 15 M C *4 In real time or when Between Cursors has been specified (during Replay) *5 1 file = 2 Gbytes (depends on the USB memory stick used) *6 Please install two battery packs. *7 Connections are made to both the BNC terminal and M3 screw terminal for the same channel. *8 Thermocouple diameters T:0.32, others:0.65 *9 Operating temperature range: -25 to +80°C h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ Wide Range of Sample Rates and Durations Long-term data can be captured directly to built-in 256-MB flash memory or to an external USB memory stick at sampling intervals of from 1 ms to 1 min. For high-speed sampling at intervals faster than 1 ms, choose the internal RAM and you can sample as fast as 100 kS/s/ch! That’s a 10 µs sample interval, suitable for very high speed data. Not very many data loggers in the world can sample this fast! Sampling Interval (Sample Rate) 10 s 100 µs (10 kS/s) 1m 40s 500 µs (2 kS/s) 1 ms (1 kS/s) 10 ms (100 S/s) 100 ms (10 S/s) 1 s (1 S/s) 8m 20 s 16m 20s 2 h 40s 1d 3h 11d 13h Internal FLASH (256 MB) X X X 11 hours 4 days 49 days 493 days Ext. USB stick (512 MB) X X X 22 hours 8 days 98 days 986 days Note: The USB stick must be a standard model without advanced features such as fingerprint recognition. Recording times shown above are approximate. Press the MENU button, then set your INPUT TYPE for each channel independently. Or use the AL channel and set ALL of the channels to be the same with one selection! High speed sampling - even during temperature measurement Even when you’re recording temperature channels, you can use the highest recording speeds. This is not possible on the slower models D820 and D220. But there are no limitations with the D900: it’s built for speed, regardless of the input type. Supports USB memory devices, Easy connection to PC via USB or Ethernet When recording VOLTAGE you can set the range for each channel independently from the selections shown above. Captured data can be saved directly to USB memory sticks - just plug one in, and then select it as your capture destination. In addition, you can connect your D900 to your Windows computer via a standard USB cable - and even transfer data in real-time! The D900 can even emulate an external USB drive for fast and convenient transfer of large data files to your PC. If you choose to connect via ethernet, you can monitor your data using a browser via the standard web server function. Open up a browser and point it to the IP address of the D900 - and you’re in business, remotely controlling and monitoring the unit from your desktop easier than ever before. When recording thermocouples, you can select from among the sensor types shown above. 13 Dataloggers D SERIES Internal RAM (up to 1 M samples) 10 µs (100 kS/s) D820 Overview Dataloggers D series 20 sets of screw terminal inputs for analog signals Additional terminal behind each +/- pair, for thermocouple connection User interface no more complicated than a mobile phone Bright 5.7” color display with multiple display modes Display can show your data in strip chart mode (Y-T), or X-Y, or numeric form. All dimensions in mm, tolerance ±5 mm 14 h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D820 Features VOLTAGE TEMPERATURE HUMIDITY TRIGGER INPUT COUNTING / RPM ◙◙ Modular expansion up to 200 analog channels! ◙◙ All channels multifunction: voltage, thermocouples, RTDs, etc. ◙◙ Thermocouples (J, K, T, E, R, S, B, N, W) (M3 screw terminal) ◙◙ Humdity: 0 to 100% (requires optional B-530 sensor) ◙◙ 1 Trigger input ◙◙ 4 channels (counting, RPM, instant and counting modes) ◙◙ 4 channels of pulse or logic inputs (selectable as a bank) Expandable from 20 to 200 Channels The standard D820 includes a terminal block on its top surface with 20 sets of inputs. However, you can replace this block with the B-537 expansion terminal, and then daisy-chain the standard block, plus up to TEN MORE blocks (option B-538) to expand the D820 from 20 channels to 40, 60, 80, 100, 120, 140, 160, 180 or even 200 channels! When you are using the included Windows remote control software, you can control and manage up to 500 channels or ten D820 systems (whichever comes first). So for example, you could remotely control five D820s with 80 channels each PLUS five more D820s with 20 channels each. As long as the channel count doesn’t exceed 500, and the D820 unit count doesn’t exceed ten, any combination is possible. Great GUI / Display The D820 features a bright clear 5.7” color TFT monitor (VGA: 640 x 480 dots). Makes it easy to read data in waveform or digital form and to check your measurement parameter settings. You can show your data in these formats: n n Waveforms + digital values n n Enlarged waveforms n n Digital values + calculation results n n Past and present data SPLIT SCREEN display Buttons to the right of the screen complete the GUI, which is no more complicated to operate than the average mobile phone. The free running display allows you to monitor your data right on the screen, even when you’re not recording it. And because waveforms are displayed on each setup screen, you can even change your settings while viewing the data. D820 data logger High Voltage Capable The wide 500 V range allows 240 VAC power supply voltage waveform measurements. Using voltage, current AND a logic input allows simultaneous measurement of a test article’s power supply voltage, current and sequential control of various points. 15 Dataloggers D SERIES LOGIC / PULSE Key Features D820 Specifications Main system Analog input channels Dataloggers D series External I/O channels Voltage Temperature 20 ch, Expandable up to 200 ch by unit of 20 ch *1 Sample rates / intervals Time/division 1 x Trigger or Sampling input 4 x Logic or Pulse inputs 4 x Alarm outputs Up to 100 S/s/ch Intervals: 10 ms to 1 h (voltage only at rates from 10 ms to 50 ms) Rates are limited by number of channels installed Plus external rate control 1 sec to 24 hours/division Trigger functions Actions Sources Combinations Conditions Alarm functions Detecting method Condition Alarm outputs * 1 Pulse input function * 1 Count mode Instant count mode RPM count mode Max. input pulse rate Start or stop capturing data based on trigger Start: Off, Input signal, Alarm, External * 1 , Clock, Week or Time Stop: Off, Input signal, Alarm, External * 1 , Clock, Week or Time OR or AND condition at the level of signal or edge of signal Analog: Rising, Falling, Window-in, Window-out Pulse: Rising, Falling, Window-in, Window-out Logic: Rising, Falling Humidity 0, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, and 1-5 V/F.S. Thermocouple: K, J, E, T, R, S, B, N, and W (WRe5-26) Resistance Temperature Detectors (RTDs): Pt100, JPt100(JIS), Pt1000(IEC751) 0 to 100% (using humidity sensor (B-530 optional), the D820 can supply power to maximum one B-530 sensor) Filter Off, 2, 5, 10, 20, 40 (moving average in selected number) Humdity input 0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option) Input filter Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel) Accuracy, voltage* 4 0.1 % of F.S. Accuracy, temperature* 4 Type: R / S: Meas range: 0°C ≤ TS ≤100°C 100°C < TS ≤300°C R:300°C < TS ≤1600°C S:300°C < TS ≤1760°C Accuracy: ±5.2°C ±3.0°C ±(0.05% of rdg +2.0°C) ±(0.05% of rdg +2.0°C) B: 400°C ≤ TS ≤600°C 600°C < TS ≤1820°C ±3.5°C ±(0.05% of rdg +2.0°C) K: -200°C ≤ TS ≤ -100°C -100°C < TS ≤ 1370°C ±(0.05% of rdg +2.0°C) ±(0.05% of rdg +1.0°C) E: -200°C ≤ TS ≤ -100°C -100°C < TS ≤ 800°C ±(0.05% of rdg +2.0°C) ±(0.05% of rdg +1.0°C) T: -200°C ≤ TS ≤-100°C -100°C < TS ≤400°C ±(0.1 % of reading + 1.5 °C) ± (0.1 % of reading + 0.5 °C) J: -200°C ≤ TS ≤-100°C -100°C < TS ≤ 100°C 100°C < TS ≤ 1100°C ±2.7°C ±1.7°C ±(0.05% of rdg +1.0°C) N: 0°C ≤ TS ≤ 1300°C ±(0.1% of rdg +1.0°C) W: 0°C ≤ TS ≤ 2000°C ±(0.1% of rdg +1.5°C) Level or edge of signal Analog: Rising, Falling, Window-in, Window-out Pulse: Rising, Falling, Window-in, Window-out Logic: Rising, Falling 4 channels, Output type: Open collector (pulled-up to 5 V by resistor 10 kΩ) Accumulating the number of pulses from the start of measurement Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S. Counting the number of pulses per sampling interval Range: 50, 500, 5 k, 50 k, 500 k, 5 M, 50 M, 500 M counts/F.S. Counting the number of pulses per second and then it is converted to RPM Range: 50 rpm, 500 rpm, 5 krpm, 50 krpm, 500 krpm, 5 Mrpm, 50 Mrpm, 500 Mrpm /F.S. 50 k pulses/sec or 50k counts per sampling interval (16 bits counter is used) Reference Junction Compensation (R.J.C.): ±0.5 °C RTD Measurement range Measurement accuracy Addition, Subtraction, Multiplication and Division for analog input Select two calculations from Average, Peak, Max., Min., RMS Pt100 -200 °C to 850 °C (FS = 1050 °C) ±1°C Search function Search for analog signal levels, values of logic or pulse or alarm point in captured data JPt100 -200 °C to 500 °C (FS = 700 °C) ±0.8 °C Interface to PC Ethernet (10 BASE-T/100 BASE-TX), USB (Full speed) PT1000 Storage device Built-in Flash memory (2 giga-bytes), USB memory device * 2 -200 °C to 500 °C (FS = 700 °C) -200 °C to 500 °C (FS = 700 °C) Calculation functions Between channels Statistical Data saving function Captured data Others Direct saving of data into built-in Flash memory or USB memory device Setting conditions, Screen copy Ring capturing mode Function: ON/OFF, Number of capturing point: 1000 to 2000000 (size of the capture data will be limited to 1/3 of available memory when in Ring Mode) USB device mode USB Memory emulation mode (Transfer or delete files in built-in memory) Channel scaling function Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output). Maximum input voltage Between + / - terminal: 60 V p-p Between channels: 60 V p-p Between channel / GND: 60 V p-p Withstand voltage Between channels: 350 V p-p (1 minute) Between channel(-)/ GND: 350 V p-p (1 minute) Control software specifications OS compatibility Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions) Software functions Up to 10 systems can be controlled Controls real-time data capture, data conversion to Excel & text Captured data Transfers data in real-time (in binary or CSV format), saved data in D820 or the USB memory Displayed information Analog waveforms, Logic waveforms, Pulse waveforms, Digital values 5.7 inch TFT color LCD (VGA: 640 x 480 dots) Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital Display modes Y-T waveforms, Digital values, Report, X-Y graph (specified period of data, data reply only) Warning functions Sends E-mail to the specified address when the alarms occur Operating environment 0 to 45 °C, 5 to 85 %RH (When operating with battery pack 0 to 40 °C, charging battery 15°C to 35 °C) Report function Creates the daily or monthly report automatically (can also export directly to Excel) Power source AC adapter (100 to 240 V, 50/60 Hz), DC power (8.5 to 24 V DC, max. 26.4 V) * 10 , Battery pack * 3 Options and accessories Power consumption 32 VA or lower (when operating with AC adapter, displaying LCD, charging battery pack) Channel extension terminal base kit (one required for adding expansion units) B-537, including cable Dimensions W x H x D (approx.) 232 x 152 x 50 mm 9.13 x 5.98 x 1.96 in. 20 channel expansion unit B-538, includes fixing plate Logic alarm cable B-513 (2 meters, flying leads) Weight (approx) 900 g (Excluding AC adapter and battery pack) 1.98 lbs (Excluding AC adapter and battery pack) DC power input cable B-514 (2 meters, flying leads) Humidity sensor B-530, 3 meters, includes plug to 5V power on D820 Display Size Formats Mechanical Input specifications 16 Input ranges Input terminals M3 screw terminals Input configuration Photo-MOS-relay scan, all channels isolated and balanced A/D type Delta-sigma type, 16-bits (effective resolution 1/40,000 of meaurement range FS) Notes *1 Logic alarm cable (B-513) option is required. *2 Size of the USB memory device is unlimited. Maximum file size is limited to 2GB. *3 DC drive cable (B-514) or battery pack (B-517) option is required. *4 Subject to the following conditions: Room Temperature is 23°C ±5°C, 30 minute warm-up time, sample rate of 1s on 20 channels max., GND terminal is connected to ground *5 Operating environment: -25°C to +85°C max. h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D820 Details Wide Range of Sample Rates Sample rates up to 100S/s/ch (10 ms interval) can be selected, depending on the number of channels being recorded. Here is how it works: Sampling Interval (ms) 10 20 50 100 200 500 1000 Number of channels 1 2 5 10 20 50 100 2000 200 Voltage measurements √ √ √ √ √ √ √ √ Temperature measurements X X X √ √ √ √ √ Note: for humidty measurements, the 0-1V range and scaling functions are used to display your results directly in % RH. Sampling rate limitations are same as those for voltage measurement. The 2GB Flash Memory enables secure long term data measurement without using an external storage device. Data is retained even when power is turned off because flash memory is used. Also supports popular USB memory sticks for external storage. The D820 saves measured data directly to USB memory sticks. USB memory sticks can be replaced during measurement without data loss. Capturing time Sampling Interval (ms) *3 *4 To the built-in FLASH memory (recording time in DAYS) To a 512 MB USB memory stick (recording time in DAYS) (20 Analog channels being used.) 10 50 100 200 29 72 89 101 7 18 22 25 500 1,000 10,000 253 506 5,068 64 129 1,294 Note: for humidty measurements, the 0-1V range and scaling functions are used to display your results directly in % RH. Sampling rate limitations are same as those for voltage measurement. Notes: *3 Estimate of recording times are approximate *4 The sample rate is limited by the number of channels in use. 10 ms = 1 channel; 50 ms = 5 channels, etc. *5 Standard USB memory devices without high-end functions such as fingerprint recognition are required Ring memory function This is the so-called “black box” mode, where the memory is a circular buffer that stores the most recent information. You can activate this mode when either internal memory or external memory is used. Captured data size in ring memory mode is limited to 1/3 of available memory. It’s Alarming! The D820 features FOUR alarm outputs, which you can define to watch for various conditions being met. When it happens, the system will output the alarm, which you can connect to another system to play a sound, or activate a relay, etc. Note - Accessing the alarm signals requires the optional B-513 cable. Isolated for your protection... The D820’s isolated input system ensures that your important signals are not corrupted by ground loops or crosstalk from other channels. Isolation is the best possible way to eliminating wiring and grounding concerns. The D820s multi-type inputs are suitable for voltage, temperature, humidity, pulse, and logic signals, enabling combined measurements of different phenomena like temperature/humidity and voltage. Supports USB memory devices, Easy connection to PC via USB or Ethernet Captured data can be saved directly to USB memory sticks - just plug one in, and then select it as your capture destination. In addition, you can connect your D820 to your Windows computer via a standard USB cable - and even transfer data in real-time! The D820 can even emulate an external USB drive for fast and convenient transfer of large data files to your PC. If you choose to connect via ethernet, you can monitor your data using a browser via the standard web server function, or use FTP client-server functionality. NTP (network time protocol) is also supported when the D820 is connected to the LAN via the Ethernet port. 17 Dataloggers D SERIES Built-in 2 GB Flash Memory for reliable long-term measurements D220 Overview Dataloggers D series 10 sets of screw terminal inputs for analog signals User interface no more complicated than a mobile phone Bright 4.3” color display with multiple display modes 18 h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ D220 Features VOLTAGE TEMPERATURE HUMIDITY TRIGGER INPUT Key Features ◙◙ ±20 mV to ±50V on screw terminal connectors ◙◙ Built-in 2 GB flash memory ◙◙ Ring buffer function ◙◙ Sample rates up to 100 S/s/ch (10 ms interval) ◙◙ 4 channels (counting, RPM, inst. mode) ◙◙ 4 channels of pulse or logic inputs (selectable as a bank) COUNTING / RPM Great GUI / Display The D220 features a great 4.3” color TFT display that serves as the user interface. You can show your data in these formats: n n Waveforms + digital values n n Enlarged waveforms n n Digital values + calculation results Multifunction Analog Inputs The inputs are simultaneously sampled with 16-bit A/D converters. You can set the sample rate anywhere from 1 S/minute/ch to 100 kS/s/ch (10 µs interval) when capturing to the internal RAM. Or you can select to capture to a USB stick that you plug in, at rates from 1 S/minute/ch to 1 kS/s/ch (1 ms interval). Most signals are input via the insulated BNC connectors, while the thermocouples are connected via the M3 screw terminal connectors. Thermocouple cables diameters up to 0.32 can be used. n n X-Y graph Buttons to the right of the screen complete the GUI, which is no more complicated to operate than the average mobile phone. You can run the display at high speeds if needed: up to 10 ms/division. At the other extreme you can run the display as slowly as 24 hours/division! The free running display allows you to monitor your data right on the screen, even when you’re not recording it. And because waveforms are displayed on each setup screen, you can even change your settings while viewing the data. D220 data logger 19 Dataloggers D SERIES LOGIC / PULSE D220 Specifcations Dataloggers D series Main system Analog input channels 10 External I/O channels Trigger input (1 channel), Logic input (4 channels) or Pulse input (4 channels) Alarm output (4 channels) Sample rate (interval) 1 S/m to 100 S/s (10 µs) Time/division 10 ms/div to 24 hours/div Timer functions Date and time, daily cycle, hourly cycle Withstand voltage: Between 1 minute Between 1 minute Thermocouple accuracy* 8 Type: R / S: Meas range: 0°C ≤ TS ≤100°C 100°C < TS ≤300°C R:300°C < TS ≤1600°C S:300°C < TS ≤1760°C Accuracy: ±7.0°C ±5.0°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +3.0°C) B: 400°C ≤ TS ≤600°C 600°C < TS ≤1820°C ±5.5°C ±(0.05% of rdg +3.0°C) K: -200°C ≤ TS ≤ -100°C -100°C < TS ≤ 1370°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C) E: -200°C ≤ TS ≤ -100°C -100°C < TS ≤ 800°C ±(0.05% of rdg +3.0°C) ±(0.05% of rdg +2.0°C) T: -200°C ≤ TS ≤-100°C -100°C < TS ≤400°C ±(0.1% of rdg +2.5°C) ±(0.1% of rdg +1.5°C) J: -200°C ≤ TS ≤-100°C -100°C < TS ≤ 100°C 100°C < TS ≤ 1100°C ±3.7°C ±2.7°C ±(0.05% of rdg +2.0°C) N: 0°C ≤ TS ≤ 1300°C ±(0.1% of rdg +2.0°C) W: 0°C ≤ TS ≤ 2000°C ±(0.1% of rdg +2.5°C) Trigger input Trigger types Start: Data capture starts on trigger Stop: Data capture stops on trigger Trigger conditions Start: Off, Input signal level (analog, logic/pulse), External* 1 Trigger combinations Input signal level: Level OR, Level AND, Edge OR, Edge AND Trigger modes H (Rising), L (Falling), Window In* 2 , Window Out* 2 Alarm function Alarm functions Rising, Falling, Window In* 2 , Window Out* 2 Alarm output Number of channels: 4, Open collector output (5V, 10 kΩ pull-up resistance) Pulse input RPM mode 50 to 20 M RPM/F.S. (in steps of 1, 2, or 5) Count mode 50 to 20 M C/F.S. (in steps of 1, 2, or 5) Inst mode 50 to 20 M C/F.S. (in steps of 1, 2, or 5) General @ 23°C±5°C, after 30 minute warm-up time. Filter : Line GND : connected Calculation functions Statistical calculations* 4 : Average, Peak, Maximum, Minimum, RMS (2 calculations can be set simultaneously) PC interface Ethernet (10BASE-T/100BASE-TX), USB (High Speed supported) provided as standard Ethernet functions Web server, FTP server, NTP client OS compatibility USB functions USB drive mode (File transfer and deletion from internal RAM memory) Windows 2000, Windows XP, Windows Vista (32-bit and 64-bit versions) Software functions D900 control, real-time data capture, data conversion to Excel & text Internal memory One million data points / Internal flash memory:Approx. 256 MB Remote setup Amplifier, data capture, trigger settings, alarm settings, and more External memory USB memory slot (High speed supported) USB memory slot (High speed supported) USB memory slot (High speed supported)* 5 Display information Analog waveforms, logic waveforms, pulse waveforms, digital values Data capture Display screens Waveforms + digital values, enlarged waveforms, digital values + calculation results, X-Y Real-time data: Binary: Sampling speed: 10 μs to 60 s CSV: Sampling speed: 10 ms to 60 s Data conversion Data between cursors, or all data Display hardware 5.7” diagonal color LCD TFT display 2-screen mode Simultaneous display of real-time data and recorded data (history) Withstand voltage Between each input channel and GND: 1000 V p-p for one minute, between input terminals: 1000 Vp-p for one minute Statistical display Maximum, minimum, and average values AC power input 100 to 240 VAC, 50 to 60 Hz, external AC/DC adapter is included Battery pack*6 B-517 DC power input 8.5 to 24 VDC Logic alarm cable B-513, 2 meters Battery power Two batteries can be installed (optional) DC power input cable B-514, 2 meters Power consumption 42 VA (when operating and charging batery with AC power) Humidity sensor *9 B-530, 3 meters Safety voltage probe RIC-141, 1:1 input/output, 42 pF BNC to BNC cable RIC-112, 1.5 meters BNC to banana plug cable RIC-113, 1.5 meters BNC - alligator clip cable RIC-114, 1.5 meters Rod-shaped K-type thermocouple RIC-410, 1.1 meters K-type thermocouple for static surfaces RIC-420, 1.1 meters L-shaped K-type thermocouple for static surfaces RIC-430, 1.1 meters Power supply Mechanical Dimensions W x H x D 232 x 150 x 80 mm (approx) Weight 1.1 kg (approx., excluding AC adapter and battery) Operating environment 0 to 40°C, 5 to 85% R.H. (15 to 35°C when using batteries) Vibration conditions Equivalent to automobile parts Type 1 Category A classification Input specifications 20 Accuracy conditions: input channel terminals and GND terminal: at 1000 V peak-to-peak input channel terminals: at 1000 V peak-to-peak Input terminals Voltage: insulated BNC (8) Temperature: M3 screw terminals (8) A/D subsystem 16-bit ADCs (14-bit effective) Simultaneous sampling all analog channels Isolation 500V Input ranges, voltage 20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20, 50, 100, 200, 500 V F.S., 1-5 V F.S. Thermocouple types Thermocouples : K, J, E, T, R, S, B, N, W (WRe5-26) Humdity input 0 to 100% (voltage 0 V to 1 V scaling conversion) with B-530 (option) Input filter Off, Line, 5 Hz, 50 Hz, 500 Hz (selectable on each channel) Voltage accuracy* 8 ±0.25% of F.S. Maximum permissible input voltage Between input channel + and - terminals: 20 mV to 1 V: ±30 VDC; 2 V to 500 V : ±500 VDC Between input channel terminals: 60 V peak-to-peak Between input channel terminals and GND: 60 V peak-to-peak Control software specifications Options and accessories Notes: *1 Logic alarm cable (B-513) is required. *2 Cannot be set for logic input *3 Maximum input frequency: 50 kHz, maximum number of counts: 15 M C *4 In real time or when Between Cursors has been specified (during Replay) *5 1 file = 2 Gbytes (depends on the USB memory stick used) *6 Please install two battery packs. *7 Connections are made to both the BNC terminal and M3 screw terminal for the same channel. *8 Thermocouple diameters T:0.32, others:0.65 *9 Operating temperature range: -25 to +80°C h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ Dataloggers D SERIES 21 Windows Software Included Dataloggers D series Three measurement screens are provided for real time data display, during acquisition: • Y/T display • X-Y display • FFT display Them after you’re done recording, the REPLAY screen has a great ZOOM feature so you can examine areas of interest in greater detail. Easy setup You can configure the most important parameters of the D900 using the Windows software, too. Functions like entering channels names are easier on the computer, of course, where you have a full size keyboard to work with. More analysis capabilities Need even more analytical horsepower? Why not use DS-7 software! If you buy an LT license, you can import text format data files from the D900 and perform a wide range of analytical functions: 22 ◙◙ Formula math, including trigonometry, algebra, boolean, and arithmetic ◙◙ Filtering - design your own IIR, FIR and FFT filters. Highpass, low-pass, band-pass, band-stop. Up to 10th order. Bessell, Butterworth, Chebychev ◙◙ Integration, double integration, differentiation, double integration, custom multi-sectional polynomials ◙◙ Array math processing and display in 2D and 3D modes ◙◙ Options available for power analysis, FRF, sine processing, sound level metering, order tracking... More software functions The standard windows software provides these additional capabilities: ◙◙ Direct to Excel - eliminates time-consuming file conversion ◙◙ Search function - look for specific values within the data ◙◙ CSV batch file conversion - process multiple files at once ◙◙ Thumbnail display of captured files ◙◙ Ability to open text formatted data files in DS-7-LT or higher software, for advanced analysis functions More FILE TRANSFER functions The standard windows software provides these additional capabilities: ◙◙ Web server/FTP server - Waveform display and D900 setup operations can be performed via a web browser. In addition, data files captured to the D900’s internal memory or to a USB memory stick can be transferred or deleted from PC. ◙◙ USB mode - When your D900 is connected to your PC via the USB interface, you can perform fast and easy data transfers from the internal memory to the PC. ◙◙ NTP client function - Connect the D900 to an NTP server via an Ethernet connection to synchronize D900 time with NTP server time at periodic intervals. h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/ Dataloggers D SERIES 23 Dataloggers D series USA Headquarters Dewetron, Inc. 10 High Street, Suite K Wakefield, RI 02879 USA Phone +1 401-284-3750 (GMT-5) Toll-free: +1 877-431-5166 Fax: +1 401-284-3755 Regional Offices: [email protected] www.dewamerica.com Dewetron Midwest 2142 Pontiac Road Suite 104 Auburn Hills, MI 48326 Phone: +1 (248) 613-4706 (GMT-5) Dewetron West 23046 Avenida de la Carlota, Ste 600 Laguna Hills, CA 92653 Phone: +1 (949) 241-4815 (GMT-8) Dewetron Southeast 22 West Bryan St. #136 Savannah GA 31401 Phone: +1 (912) 344-6918 (GMT-5) Sales Agents: We have sales agents located all over the USA, Canada, Mexico, Central America, and South America. Please contact DEWETRON to find your closest office, or visit our website to learn more: http://www.dewamerica.com/Contact/ DEWETRON, INC. • 10 High Street, Ste K • Wakefield•RI•02879•USA Tel (+1) 401-284-3750 • Fax (+1) 401-284-3755 • [email protected] 24 h t t p://www.de wame rica.com/Produ cts/ Da ta l oggers/