HS300-1050
9 – 36 V DC 8–2A 50 W typical EMI filter, galvanic isolation 1 x 2 pin LEMO DC in, 2 x 9 pin LEMO (Link) yes for power on 48.1 x 184 x 124.5 mm (w x h x d) including fixing system 940 g typical conduction cooled
Environmental specifications Vibration Shock Operating temp. Storage temp. Humidity
Technical Specification HEIM DATaRec 4 Power Modules Overview ®
5g 10 g -30 °C - +65 °C -40 °C - +90 °C 0 - 93% relative, non-condensing
Environmental specifications Vibration Shock Operating temp. Storage temp. Humidity
AC Power Module – PWAC Input voltage Input current Max. output power Functions Connector On / off switch LED indicators Dimensions Cooling
DC Power Module – PWH9 Input voltage Input current Max. output power Functions Connector On / off switch LED indicators Dimensions Weight Cooling
©ZODIAC Data Systems GmbH
5g 10 g -30 °C - +65 °C -40 °C - +90 °C 0 - 93% relative, non-condensing
HS300-1035
90 – 130 V AC or 180 – 260 V AC, 50 – 60 Hz 3.4 – 2.5 A / 1.8 – 1.4 A 150 W typical EMI filter, galvanic isolation 1 x AC connector, 2 x 9 pin LEMO (Link) yes for power on 70.1 x 184 x 124.5 mm (w x h x d) including fixing system fan
HS300-1025
12 – 36 V DC 9,5 – 3 A 96 W typical EMI filter, galvanic isolation 1 x 2 pin LEMO DC in, 2 x 9 pin LEMO (Link) yes for power on 70.1 x 184 x 124.5 mm (w x h x d) including fixing system 1100 g typical fan switchable
Environmental specifications Vibration Shock Operating temp. Storage temp. Humidity Safety
3g 5g -10 °C - +45 °C -20 °C - +60 °C 0 - 93% relative, non-condensing EN60950
Notes It is recommend to add a 10% safety to the required power consumption of the Signal / Link Module configuration.
Page 1 of 2
Document No.: 54184106 / 54194106 / 54214106
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. This data sheet is provided for guidance only and does not constitute a warranty of any kind.
Technical Specification HEIM DATaRec® 4 Power Modules Overview
Applications
Miniature system Single module system with direct link to the PC via USB 2.0
Distributed data acquisition system Remotely located modules (up to 768 channels)
Compact system Centralized acquisition system with up to 768 channels
Distributed multi channel system Remotely located groups of modules (up to 768 channels)
ZODIAC Data Systems GmbH Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99
[email protected] – http://www.zodiac-data-systems.com ©ZODIAC Data Systems GmbH
Page 2 of 2
Document No.: 54184106 / 54194106 / 54214106
All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. This data sheet is provided for guidance only and does not constitute a warranty of any kind.