Preview only show first 10 pages with watermark. For full document please download

Datarec 4 Pwd9d Pwh9 Pwac Ft 180110

   EMBED


Share

Transcript

ZODIAC DATA SYSTEMS GMBH DC Power Module – PWD9D Input voltage Input current Max. output power Functions Connector On / off switch LED indicators Dimensions Weight Cooling HS300-1050 9 – 36 V DC 8–2A 50 W typical EMI filter, galvanic isolation 1 x 2 pin LEMO DC in, 2 x 9 pin LEMO (Link) yes for power on 48.1 x 184 x 124.5 mm (w x h x d) including fixing system 940 g typical conduction cooled Environmental specifications Vibration Shock Operating temp. Storage temp. Humidity Technical Specification HEIM DATaRec 4 Power Modules Overview ® 5g 10 g -30 °C - +65 °C -40 °C - +90 °C 0 - 93% relative, non-condensing Environmental specifications Vibration Shock Operating temp. Storage temp. Humidity AC Power Module – PWAC Input voltage Input current Max. output power Functions Connector On / off switch LED indicators Dimensions Cooling DC Power Module – PWH9 Input voltage Input current Max. output power Functions Connector On / off switch LED indicators Dimensions Weight Cooling ©ZODIAC Data Systems GmbH 5g 10 g -30 °C - +65 °C -40 °C - +90 °C 0 - 93% relative, non-condensing HS300-1035 90 – 130 V AC or 180 – 260 V AC, 50 – 60 Hz 3.4 – 2.5 A / 1.8 – 1.4 A 150 W typical EMI filter, galvanic isolation 1 x AC connector, 2 x 9 pin LEMO (Link) yes for power on 70.1 x 184 x 124.5 mm (w x h x d) including fixing system fan HS300-1025 12 – 36 V DC 9,5 – 3 A 96 W typical EMI filter, galvanic isolation 1 x 2 pin LEMO DC in, 2 x 9 pin LEMO (Link) yes for power on 70.1 x 184 x 124.5 mm (w x h x d) including fixing system 1100 g typical fan switchable Environmental specifications Vibration Shock Operating temp. Storage temp. Humidity Safety 3g 5g -10 °C - +45 °C -20 °C - +60 °C 0 - 93% relative, non-condensing EN60950 Notes It is recommend to add a 10% safety to the required power consumption of the Signal / Link Module configuration. Page 1 of 2 Document No.: 54184106 / 54194106 / 54214106 All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. This data sheet is provided for guidance only and does not constitute a warranty of any kind. Technical Specification HEIM DATaRec® 4 Power Modules Overview Applications Miniature system Single module system with direct link to the PC via USB 2.0 Distributed data acquisition system Remotely located modules (up to 768 channels) Compact system Centralized acquisition system with up to 768 channels Distributed multi channel system Remotely located groups of modules (up to 768 channels) ZODIAC Data Systems GmbH Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99 [email protected] – http://www.zodiac-data-systems.com ©ZODIAC Data Systems GmbH Page 2 of 2 Document No.: 54184106 / 54194106 / 54214106 All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. This data sheet is provided for guidance only and does not constitute a warranty of any kind.