Preview only show first 10 pages with watermark. For full document please download

Datasheet According To Emva 1288 Release 3.1

   EMBED


Share

Transcript

MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014 EMVA 1288 Summary Sheet This datasheet describes the specification according to the standard 1288 for Characterization and Presentation of Specification Data for Image Sensors and Cameras of the European Machine Vision Association (EMVA)(see www.standard1288.org). The measurements were performed with an AEON ACC3 RGB Release 3, 20.01.2104, SN 0005() . The performance parameters and estimated accuracy of the measurements are described in the technical report for the instrument, its calibration in the corresponding calibration report. Vendor Model Serial number Sensor diagonal Lens category Resolution Pixel size Sensor type Shutter type Overlap capabilities Maximum frame rate Interface type Type of data presented Single Operation point 1, (page 5) Wavelength centroid 467.3 nm Wavelength FWHM 20.5 nm Gain, offset Gain = 0dB, Offset = 0 Operation point 2, (page 17) Wavelength centroid 534.2 nm Wavelength FWHM 30.9 nm Gain, offset Gain = 0dB, Offset = 0 Operation point 3, (page 29) Wavelength centroid 629.5 nm Wavelength FWHM 13.1 nm Gain, offset Gain = 0dB, Offset = 0 Optional data measured None MATRIX VISION mvBlueCOUGAR-X105C GX008114 7.13 mm C-Mount 2592 × 1944, 12 bit 2.20 µm × 2.20 µm CMOS Rolling Pipelined 11.7 Hz GigE Vision Spectral sensitivity m0156, 11.11.2014 blue data green1 data 0,6 red data green2 data quantum efficiency 0,5 0,4 0,3 0,2 0,1 0 300 400 500 600 700 800 900 1.000 wavelength (nm) c copyright AEON, 2014 1 of 41 MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014 EMVA 1288 Summary Sheet for Operating Point 1 Type of data Exposure time Frame rate Data transfer mode Gain, offset Environmental temperature Camera temperature Wavelength, centr., FWHM Single 2.0 ms 0.0 Hz BayerGR12 Gain = 0dB, Offset = 0 23.6◦ C 34.7◦ C 467 nm, 20.5 nm Quantum efficiency η 0.403 Photon transfer m0156, 467nm, 11.11.2014 variance gray - dark value (DN^2) 2.500 K (DN/e) 1/K (e/DN) 2.000 blue fit 1.500 1.000 saturation blue: var(dark) = 12.47 DN^2, K = 0.534 +-0.1% 0 1.000 2.000 3.000 0.534 1.874 Dark noise & DSNU σd (DN) 3.53 σ0 (e) 6.6 DSNU1288 (DN) 0.78 DSNU1288 (e) 1.47 Signal-to-noise ratio & PRNU SNRmax 84 SNRmax (dB) 38.5 SNRmax (bits) 6.4 1/SNRmax (%) 1.19 PRNU1288 (%) 2.759 500 0 Gain blue data 4.000 gray value - dark value (DN) Nonlinearity LE (%) 0.07 SNR m0156, 467nm, 11.11.2014 blue data 1.000 blue fit SNR 100 Sensitivity & saturation µp,min (p) 17.7 µe,min (e) 7.1 µp,sat (p) 17398 µe,sat (e) 7020 Dynamic range 10 blue fit total threshold SNR = 1 DR DR (dB) DR (bit) 983 59.9 9.9 Dark current µc,mean (DN/s) µc,mean (e/s) µc,var (e/s) 140.63 263.57 22.16 1 theor. limit saturation 10 100 1.000 10.000 100.000 irradiation (photons/pixel) 2 of 41 1e+06 1e+07 c copyright AEON, 2014 MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014 EMVA 1288 Summary Sheet for Operating Point 2 Type of data Exposure time Frame rate Data transfer mode Gain, offset Environmental temperature Camera temperature Wavelength, centr., FWHM Single 2.0 ms 0.0 Hz BayerGR12 Gain = 0dB, Offset = 0 23.6◦ C 34.7◦ C 534 nm, 30.9 nm Quantum efficiency η 0.411 Photon transfer m0156, 534nm, 11.11.2014 Gain 2.500 variance gray - dark value (DN^2) green1 data 2.000 K (DN/e) 1/K (e/DN) 0.541 1.849 green2 data green1 fit 1.500 green2 fit 1.000 Signal-to-noise ratio & PRNU SNRmax 83 SNRmax (dB) 38.4 SNRmax (bits) 6.4 1/SNRmax (%) 1.21 PRNU1288 (%) 2.674 500 0 green1: var(dark) = 12.51 DN^2, K = 0.541 +-0.1% green2: var(dark) = 12.57 DN^2, K = 0.540 +-0.1% saturation 0 1.000 2.000 3.000 Dark noise & DSNU σd (DN) 3.54 σ0 (e) 6.5 DSNU1288 (DN) 0.81 DSNU1288 (e) 1.50 4.000 gray value - dark value (DN) Nonlinearity LE (%) 0.10 SNR m0156, 534nm, 11.11.2014 green1 data 1.000 green2 data 100 SNR green1 fit Sensitivity & saturation µp,min (p) 17.2 µe,min (e) 7.1 µp,sat (p) 16702 µe,sat (e) 6870 Dynamic range green2 fit 10 green1 fit total threshold SNR = 1 DR DR (dB) DR (bit) 973 59.8 9.9 Dark current µc,mean (DN/s) µc,mean (e/s) µc,var (e/s) -27.38 -50.64 86.81 1 green2 fit total theor. limit saturation 10 100 1.000 10.000 100.000 irradiation (photons/pixel) c copyright AEON, 2014 1e+06 1e+07 3 of 41 MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014 EMVA 1288 Summary Sheet for Operating Point 3 Type of data Exposure time Frame rate Data transfer mode Gain, offset Environmental temperature Camera temperature Wavelength, centr., FWHM Single 2.0 ms 0.0 Hz BayerGR12 Gain = 0dB, Offset = 0 23.6◦ C 34.7◦ C 630 nm, 13.1 nm Quantum efficiency η 0.277 Photon transfer m0156, 630nm, 11.11.2014 Gain 2.500 variance gray - dark value (DN^2) red data 2.000 1.500 red fit 1.000 saturation red: var(dark) = 12.53 DN^2, K = 0.527 +-0.1% 0 1.000 2.000 3.000 0.527 1.897 Dark noise & DSNU σd (DN) 3.54 σ0 (e) 6.7 DSNU1288 (DN) 0.80 DSNU1288 (e) 1.52 Signal-to-noise ratio & PRNU SNRmax 83 SNRmax (dB) 38.4 SNRmax (bits) 6.4 1/SNRmax (%) 1.20 PRNU1288 (%) 5.080 500 0 K (DN/e) 1/K (e/DN) 4.000 gray value - dark value (DN) Nonlinearity LE (%) 0.24 SNR m0156, 630nm, 11.11.2014 1.000 red data SNR 100 Sensitivity & saturation µp,min (p) 26.1 µe,min (e) 7.2 µp,sat (p) 25106 µe,sat (e) 6949 red fit 10 threshold SNR = 1 red fit total Dynamic range DR DR (dB) DR (bit) 960 59.6 9.9 Dark current µc,mean (DN/s) µc,mean (e/s) µc,var (e/s) -67.80 -128.65 -16.79 1 theor. limit saturation 10 100 1.000 10.000 100.000 irradiation (photons/pixel) 4 of 41 1e+06 1e+07 c copyright AEON, 2014