Transcript
MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014
EMVA 1288 Summary Sheet
This datasheet describes the specification according to the standard 1288 for Characterization and Presentation of Specification Data for Image Sensors and Cameras of the European Machine Vision Association (EMVA)(see www.standard1288.org). The measurements were performed with an AEON ACC3 RGB Release 3, 20.01.2104, SN 0005() . The performance parameters and estimated accuracy of the measurements are described in the technical report for the instrument, its calibration in the corresponding calibration report.
Vendor Model Serial number Sensor diagonal Lens category Resolution Pixel size Sensor type Shutter type Overlap capabilities Maximum frame rate Interface type
Type of data presented Single Operation point 1, (page 5) Wavelength centroid 467.3 nm Wavelength FWHM 20.5 nm Gain, offset Gain = 0dB, Offset = 0 Operation point 2, (page 17) Wavelength centroid 534.2 nm Wavelength FWHM 30.9 nm Gain, offset Gain = 0dB, Offset = 0 Operation point 3, (page 29) Wavelength centroid 629.5 nm Wavelength FWHM 13.1 nm Gain, offset Gain = 0dB, Offset = 0 Optional data measured None
MATRIX VISION mvBlueCOUGAR-X105C GX008114 7.13 mm C-Mount 2592 × 1944, 12 bit 2.20 µm × 2.20 µm CMOS Rolling Pipelined 11.7 Hz GigE Vision
Spectral sensitivity m0156, 11.11.2014 blue data green1 data
0,6
red data green2 data
quantum efficiency
0,5
0,4
0,3
0,2
0,1
0 300
400
500
600
700
800
900
1.000
wavelength (nm)
c copyright AEON, 2014
1 of 41
MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014
EMVA 1288 Summary Sheet for Operating Point 1 Type of data Exposure time Frame rate Data transfer mode
Gain, offset Environmental temperature Camera temperature Wavelength, centr., FWHM
Single 2.0 ms 0.0 Hz BayerGR12
Gain = 0dB, Offset = 0 23.6◦ C 34.7◦ C 467 nm, 20.5 nm
Quantum efficiency η
0.403
Photon transfer m0156, 467nm, 11.11.2014
variance gray - dark value (DN^2)
2.500
K (DN/e) 1/K (e/DN)
2.000 blue fit
1.500
1.000
saturation
blue: var(dark) = 12.47 DN^2, K = 0.534 +-0.1%
0
1.000
2.000
3.000
0.534 1.874
Dark noise & DSNU σd (DN) 3.53 σ0 (e) 6.6 DSNU1288 (DN) 0.78 DSNU1288 (e) 1.47 Signal-to-noise ratio & PRNU SNRmax 84 SNRmax (dB) 38.5 SNRmax (bits) 6.4 1/SNRmax (%) 1.19 PRNU1288 (%) 2.759
500
0
Gain
blue data
4.000
gray value - dark value (DN)
Nonlinearity LE (%)
0.07
SNR m0156, 467nm, 11.11.2014 blue data
1.000
blue fit
SNR
100
Sensitivity & saturation µp,min (p) 17.7 µe,min (e) 7.1 µp,sat (p) 17398 µe,sat (e) 7020 Dynamic range
10 blue fit total
threshold SNR = 1
DR DR (dB) DR (bit)
983 59.9 9.9
Dark current µc,mean (DN/s) µc,mean (e/s) µc,var (e/s)
140.63 263.57 22.16
1 theor. limit
saturation 10
100
1.000
10.000
100.000
irradiation (photons/pixel)
2 of 41
1e+06
1e+07
c copyright AEON, 2014
MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014
EMVA 1288 Summary Sheet for Operating Point 2 Type of data Exposure time Frame rate Data transfer mode
Gain, offset Environmental temperature Camera temperature Wavelength, centr., FWHM
Single 2.0 ms 0.0 Hz BayerGR12
Gain = 0dB, Offset = 0 23.6◦ C 34.7◦ C 534 nm, 30.9 nm
Quantum efficiency η
0.411
Photon transfer m0156, 534nm, 11.11.2014
Gain
2.500
variance gray - dark value (DN^2)
green1 data
2.000
K (DN/e) 1/K (e/DN)
0.541 1.849
green2 data
green1 fit
1.500
green2 fit
1.000
Signal-to-noise ratio & PRNU SNRmax 83 SNRmax (dB) 38.4 SNRmax (bits) 6.4 1/SNRmax (%) 1.21 PRNU1288 (%) 2.674
500
0
green1: var(dark) = 12.51 DN^2, K = 0.541 +-0.1% green2: var(dark) = 12.57 DN^2, K = 0.540 +-0.1%
saturation 0
1.000
2.000
3.000
Dark noise & DSNU σd (DN) 3.54 σ0 (e) 6.5 DSNU1288 (DN) 0.81 DSNU1288 (e) 1.50
4.000
gray value - dark value (DN)
Nonlinearity LE (%)
0.10
SNR m0156, 534nm, 11.11.2014 green1 data
1.000
green2 data
100
SNR
green1 fit
Sensitivity & saturation µp,min (p) 17.2 µe,min (e) 7.1 µp,sat (p) 16702 µe,sat (e) 6870 Dynamic range
green2 fit
10
green1 fit total
threshold SNR = 1
DR DR (dB) DR (bit)
973 59.8 9.9
Dark current µc,mean (DN/s) µc,mean (e/s) µc,var (e/s)
-27.38 -50.64 86.81
1 green2 fit total theor. limit
saturation 10
100
1.000
10.000
100.000
irradiation (photons/pixel)
c copyright AEON, 2014
1e+06
1e+07
3 of 41
MATRIX VISION, mvBlueCOUGAR-X105C, GX008114, November 11, 2014
EMVA 1288 Summary Sheet for Operating Point 3 Type of data Exposure time Frame rate Data transfer mode
Gain, offset Environmental temperature Camera temperature Wavelength, centr., FWHM
Single 2.0 ms 0.0 Hz BayerGR12
Gain = 0dB, Offset = 0 23.6◦ C 34.7◦ C 630 nm, 13.1 nm
Quantum efficiency η
0.277
Photon transfer m0156, 630nm, 11.11.2014
Gain
2.500
variance gray - dark value (DN^2)
red data
2.000
1.500 red fit
1.000
saturation
red: var(dark) = 12.53 DN^2, K = 0.527 +-0.1%
0
1.000
2.000
3.000
0.527 1.897
Dark noise & DSNU σd (DN) 3.54 σ0 (e) 6.7 DSNU1288 (DN) 0.80 DSNU1288 (e) 1.52 Signal-to-noise ratio & PRNU SNRmax 83 SNRmax (dB) 38.4 SNRmax (bits) 6.4 1/SNRmax (%) 1.20 PRNU1288 (%) 5.080
500
0
K (DN/e) 1/K (e/DN)
4.000
gray value - dark value (DN)
Nonlinearity LE (%)
0.24
SNR m0156, 630nm, 11.11.2014 1.000 red data
SNR
100
Sensitivity & saturation µp,min (p) 26.1 µe,min (e) 7.2 µp,sat (p) 25106 µe,sat (e) 6949
red fit
10
threshold SNR = 1
red fit total
Dynamic range DR DR (dB) DR (bit)
960 59.6 9.9
Dark current µc,mean (DN/s) µc,mean (e/s) µc,var (e/s)
-67.80 -128.65 -16.79
1 theor. limit
saturation 10
100
1.000
10.000
100.000
irradiation (photons/pixel)
4 of 41
1e+06
1e+07
c copyright AEON, 2014