Transcript
EN v1.0
central PSU Very fast installation time Fully weather resistant Can supply power up to 10 PIDboxes Mini Custom solutions for every customer
What is the central Power Supply Unit (PSU)? The central PSU is a device that makes the installation of iLumen’s PIDbox Mini Outdoor very easy for larger PV-plants. It is able to supply power up to 10 PIDboxes Mini Outdoor. Since the central PSU is rated IP66, it is fully resistant to all weather conditions. In order to supply DC-power to the PIDboxes Mini Outdoor, simply supply the central PSU with AC-power and attach the connectors to the PIDboxes Mini Outdoor. Since every PV-plant has a different inverter position, iLumen supplies custom made solutions. Simply fill in the request form on the iLumen website and provide us the different cable lengths. We will offer you a custom solution for your specific PV-installation.
Go to our website and fill in the online request form Get your free quote for your custom made central PSU
Central PSU
DC out
AC in
Contact
Ambachtstraat 19 - 3980 Tessenderlo - Belgium
To measure is to know!
tel +32 (0) 13 30 61 77
[email protected]
www.ilumen.be
www.ilumen.be
Technical data
ILUMEN CENTRAL PSU
INPUT (AC) Voltage range Frequency range Efficiency Nominal AC-current Max AC-current Power consumption in standby operation Typical power consumption in operation Maximum power consumption Typical consumption per day * Maximum allowed cable section
88-132 VAC //176-264 VAC (specify when ordering) 47-63 Hz 86% 1.0 A 2.0 A 25 W 125 W 155 W 1.3 kWh/day (* for 10 PIDboxes Mini OUTDOOR) 2.5 mm²
OUTPUT (DC) Nominal voltage 18-20 VDC Protection fuse 8.0 A Cable section per individial cable 2x0.5 mm² Only use the included PSU or this central PSU for powering the PIDbox Mini as this device requires a specific voltage. Using any other PSU will void the warranty. GENERAL DATA Dimensions (W x D xH) Weight Environmental conditions Working temperature range Working humidity Storage temp / humidity Maximum number of PIDboxes OUTDOOR SAFETY Safety standards EMC emission EMC immunity
280 x 200 x 300 mm (without cable glands) 3.5 kg (without DC-cables) IP66 (indoor and outdoor use) -25 to +70°C 20-90% RH non-condensing -40 to +80°C / 10-95% RH 10 (specify the number of PIDboxes on the request form)
UL60950-1, TUV EN60950-1 approved Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
EC DECLARATION OF CONFORMITY With the guidelines of the European Directives
- Low Voltage Directive (73/23/EEC, 93/68/EEC) - Electromagnetic Compatibility Directive (89/336/EEC)
Contact
Ambachtstraat 19 - 3980 Tessenderlo - Belgium For general terms and conditions go to www.ilumen.be
To measure is to know!
tel +32 (0) 13 30 61 77
Go to our website and fill in the online request form Get your free quote for your custom made central PSU
[email protected]
www.ilumen.be
www.ilumen.be