Preview only show first 10 pages with watermark. For full document please download

Datasheet For Al602uladaj By Altronix

   EMBED


Share

Transcript

AL602ULADAJ NAC Power Extenders Rev. AL602ULADAJ_11072012 Overview AL602ULADAJ are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories. AL602ULADAJ Specifications Agency Listings: •฀ UL฀Listed฀Control฀Units฀and฀Accessories฀for฀ Fire Systems (UL 864). •฀ MEA฀-฀NYC฀Department฀of฀Buildings฀Approved. •฀ CSFM฀-฀California฀State฀Fire฀Marshal฀Approved. •฀ FM฀-฀Factory฀Mutual฀Approved. •฀ NFPA฀72฀Compliant. Input: •฀ ฀Power฀input฀120VAC฀60฀Hz,฀4฀amp. •฀ Two฀(2)฀Class฀A,฀Style฀Z฀or฀two฀(2)฀Class฀B, ฀ Style฀W,฀X,฀Y฀FACP฀inputs. •฀ Two฀(2)฀NC฀dry฀contact฀trigger฀inputs. Output: •฀ 24VDC฀@฀6.5฀amp฀max฀total฀alarm฀current. •฀ 2.5฀amp฀max฀current฀per฀output. •฀ Separate฀1.0฀amp฀auxiliary฀output. •฀ Two฀(2)฀outputs฀may฀be฀paralleled฀for฀more฀power฀on฀฀ an indicating circuit. •฀ Programmable฀supervised฀indicating฀circuit฀outputs:฀฀฀ ฀ Four฀(4)฀Class฀B,฀Style฀W,฀X,฀Y฀or฀Two฀(2)฀Class฀A, ฀ Style฀Z฀or฀One฀(1)฀Class฀A,฀Style฀Z฀and฀Two฀(2)฀Class฀฀ ฀ B,฀Style฀W,฀X,฀Y. •฀฀฀Thermal฀and฀short฀circuit฀protection฀with฀auto฀reset.฀ Battery Backup: •฀ Charging฀voltage฀is฀26.2-26.4VDC. •฀฀฀Built-in฀charger฀for฀sealed฀lead฀acid฀or฀gel฀type฀batteries.฀ •฀฀฀Automatic฀switchover฀to฀stand-by฀battery฀when฀ AC Fails. •฀ Zero฀voltage฀drop฀when฀switching฀over฀to฀ battery backup. Supervision: •฀฀AC฀fail฀supervision฀(form฀“C”฀contact,฀1฀amp฀/฀28VDC).฀ ฀ Factory฀set฀for฀30฀seconds฀with฀optional฀2.5฀to฀3฀hour฀฀ delay setting (field selectable). •฀ Instant฀local฀AC฀trouble฀reporting฀relay ฀ (form฀“C”฀contact,฀1฀amp฀/฀28VDC). •฀฀Battery฀presence฀and฀low฀battery฀supervision฀ ฀ (form฀“C”฀contact,฀1฀amp฀/฀28VDC). Visual Indicators: •฀฀Input฀and฀output฀status฀LED฀indicators.฀ Special Features: •฀ 2-wire฀horn/strobe฀Sync฀mode฀allows฀audible฀ notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. •฀ Temporal฀Code฀3,฀Steady฀Mode,฀Input฀to฀Output฀฀ ฀ Follower฀Mode฀(maintains฀synchronization฀of฀ notification appliances circuit). •฀ Compatible฀with฀12VDC฀or฀24VDC฀fire฀panels.฀฀฀฀ •฀฀Output฀loop฀supervision฀steered฀to฀input฀1฀or฀input฀2. •฀ Signal฀circuit฀trouble฀memory฀(helps฀identify฀ intermittent loop problems). •฀ Common฀trouble฀input฀and฀output฀for฀external฀trouble฀฀ ฀ signals฀tie-in. •฀ Ground฀fault฀detection.฀ Added Features: •฀฀Unit฀includes฀power฀supply,฀red฀enclosure,฀cam฀lock,฀฀ and battery leads. Mechanical: •฀ Enclosure฀Dimensions฀(H฀x฀W฀x฀D฀approx.): ฀ 18”(457.2mm)฀x฀14.5”(368.3mm)฀x฀4.625”(117.48mm) •฀ Product฀weight฀(approx.):฀16.65฀lbs.฀(7.55฀kg). •฀ Shipping฀weight฀(approx.):฀18.9฀lbs.฀(8.57฀kg). Agency Approvals Altronix Corp. 140 58th St. Brooklyn, NY UL Listed Control Units and Accessories for Fire Alarm Systems (UL 864) Ninth Edition NYC Department of Buildings Approved. California State Fire Marshal Approved. Factory Mutual Approved. Enclosure Dimensions (H x W x D) (approximate): 18”฀(457.2mm)฀x฀14.5”฀(368.3mm)฀x฀4.625”฀(117.48mm) 14.5” (368.3mm) 1.5” (38.1mm) 2.5” (63.5mm) 2.5” (63.5mm) 1.5” (38.1mm) 4.625” (117.475mm) 1.0” (25.4mm) 1.25” (31.75mm) 1.5” (38.1mm) 1.25” (31.75mm) 1.5” (38.1mm) 1.0” (25.4mm) 1.0” (25.4mm) 1.5” (38.1mm) 2.5” (63.5mm) 8.5” (215.9mm) 6.0” (152.4mm) 18.0” (457.2mm) 18.0” (457.2mm) 1.0” (25.4mm) 1.0” (25.4mm) 1.0” (25.4mm) 2.75” (69.85mm) 1.5” (38.1mm) 14.5” (368.3mm) 4.5” (114.3mm) 4.5” (114.3mm) 14.5” (368.3mm) Altronix฀Corp.฀-฀140฀58th฀Street,฀Brooklyn,฀NY฀11220฀•฀718-567-8181฀•฀888-258-7669฀•฀altronix.com 2.75” (69.85mm) 18.0” (457.2mm)