AL602ULADAJ NAC Power Extenders Rev. AL602ULADAJ_11072012
Overview AL602ULADAJ are extremely cost effective voltage regulated remote NAC Power Extenders. They may be connected to any 24 volt Fire Alarm Control Panel (FACP). Primary applications include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and providing auxiliary power to support system accessories.
AL602ULADAJ
Specifications Agency Listings: • ULListedControlUnitsandAccessoriesfor Fire Systems (UL 864). • MEA-NYCDepartmentofBuildingsApproved. • CSFM-CaliforniaStateFireMarshalApproved. • FM-FactoryMutualApproved. • NFPA72Compliant. Input: • Powerinput120VAC60Hz,4amp. • Two(2)ClassA,StyleZortwo(2)ClassB, StyleW,X,YFACPinputs. • Two(2)NCdrycontacttriggerinputs. Output: • 24VDC@6.5ampmaxtotalalarmcurrent. • 2.5ampmaxcurrentperoutput. • Separate1.0ampauxiliaryoutput. • Two(2)outputsmaybeparalleledformorepoweron an indicating circuit. • Programmablesupervisedindicatingcircuitoutputs: Four(4)ClassB,StyleW,X,YorTwo(2)ClassA, StyleZorOne(1)ClassA,StyleZandTwo(2)Class B,StyleW,X,Y. •Thermalandshortcircuitprotectionwithautoreset. Battery Backup: • Chargingvoltageis26.2-26.4VDC. •Built-inchargerforsealedleadacidorgeltypebatteries. •Automaticswitchovertostand-bybatterywhen AC Fails. • Zerovoltagedropwhenswitchingoverto battery backup.
Supervision: •ACfailsupervision(form“C”contact,1amp/28VDC). Factorysetfor30secondswithoptional2.5to3hour delay setting (field selectable). • InstantlocalACtroublereportingrelay (form“C”contact,1amp/28VDC). •Batterypresenceandlowbatterysupervision (form“C”contact,1amp/28VDC). Visual Indicators: •InputandoutputstatusLEDindicators. Special Features: • 2-wirehorn/strobeSyncmodeallowsaudible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. • TemporalCode3,SteadyMode,InputtoOutput FollowerMode(maintainssynchronizationof notification appliances circuit). • Compatiblewith12VDCor24VDCfirepanels. •Outputloopsupervisionsteeredtoinput1orinput2. • Signalcircuittroublememory(helpsidentify intermittent loop problems). • Commontroubleinputandoutputforexternaltrouble signalstie-in. • Groundfaultdetection. Added Features: •Unitincludespowersupply,redenclosure,camlock, and battery leads.
Mechanical: • EnclosureDimensions(HxWxDapprox.): 18”(457.2mm)x14.5”(368.3mm)x4.625”(117.48mm) • Productweight(approx.):16.65lbs.(7.55kg). • Shippingweight(approx.):18.9lbs.(8.57kg).
Agency Approvals Altronix Corp. 140 58th St. Brooklyn, NY
UL Listed Control Units and Accessories for Fire Alarm Systems (UL 864) Ninth Edition NYC Department of Buildings Approved.
California State Fire Marshal Approved.
Factory Mutual Approved.
Enclosure Dimensions (H x W x D) (approximate): 18”(457.2mm)x14.5”(368.3mm)x4.625”(117.48mm) 14.5” (368.3mm) 1.5” (38.1mm)
2.5” (63.5mm)
2.5” (63.5mm)
1.5” (38.1mm)
4.625” (117.475mm)
1.0” (25.4mm)
1.25” (31.75mm) 1.5” (38.1mm)
1.25” (31.75mm)
1.5” (38.1mm) 1.0” (25.4mm)
1.0” (25.4mm)
1.5” (38.1mm)
2.5” (63.5mm)
8.5” (215.9mm)
6.0” (152.4mm)
18.0” (457.2mm)
18.0” (457.2mm)
1.0” (25.4mm)
1.0” (25.4mm) 1.0” (25.4mm)
2.75” (69.85mm)
1.5” (38.1mm)
14.5” (368.3mm)
4.5” (114.3mm)
4.5” (114.3mm) 14.5” (368.3mm)
AltronixCorp.-14058thStreet,Brooklyn,NY11220•718-567-8181•888-258-7669•altronix.com
2.75” (69.85mm)
18.0” (457.2mm)