Series AM3TW-Z 3 Watt | DC-DC Converter FEATURES: • • • •
RoHS compliant Low profile metal package High efficiency up to 82% Wide 4:1 input range
• • • •
Operating temperature -40oC to + 85oC Input / Output Isolation 1500 and 3500VDC Pin compatible with multiple manufacturers Continuous short circuit protection
Models Single output Model
Input Voltage (V)
Output Voltage (V)
Output Current max (mA)
Isolation (VDC)
Capacitive load, max ( F)
Efficiency (%)
AM3TW-2403SZ AM3TW-2405SZ AM3TW-2407SZ AM3TW-2409SZ AM3TW-2412SZ AM3TW-2415SZ AM3TW-2418SZ AM3TW-2424SZ AM3TW-4803SZ AM3TW-4805SZ AM3TW-4807SZ AM3TW-4809SZ AM3TW-4812SZ AM3TW-4815SZ AM3TW-4818SZ AM3TW-4824SZ
9-36 9-36 9-36 9-36 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72
3.3 5 7.2 9 12 15 18 24 3.3 5 7.2 9 12 15 18 24
800 600 417 333 250 200 167 125 800 600 417 333 250 200 167 125
1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500
1000 1000 200 200 100 100 47 47 1000 1000 200 200 100 100 47 47
75 78 78 79 81 81 81 81 76 80 78 82 80 80 80 81
AM3TW-2403SH35Z AM3TW-2405SH35Z AM3TW-2407SH35Z AM3TW-2409SH35Z AM3TW-2412SH35Z AM3TW-2415SH35Z AM3TW-2418SH35Z AM3TW-2424SH35Z AM3TW-4803SH35Z AM3TW-4805SH35Z AM3TW-4807SH35Z AM3TW-4809SH35Z AM3TW-4812SH35Z AM3TW-4815SH35Z AM3TW-4818SH35Z AM3TW-4824SH35Z
9-36 9-36 9-36 9-36 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72
3.3 5 7.2 9 12 15 18 24 3.3 5 7.2 9 12 15 18 24
800 600 417 333 250 200 167 125 800 600 417 333 250 200 167 125
3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500
1000 1000 200 200 100 100 47 47 1000 1000 200 200 100 100 47 47
75 78 78 79 81 81 81 81 76 80 78 82 80 80 80 81
Output Voltage (V)
Output Current max (mA)
Isolation (VDC)
Capacitive load, max ( F)
Efficiency (%)
±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18
±400 ±300 ±208 ±167 ±125 ±100 ±84
1500 1500 1500 1500 1500 1500 1500
±470 ±470 ±100 ±100 ±68 ±68 ±33
76 79 78 79 80 80 81
Models Dual output Model AM3TW-2403DZ AM3TW-2405DZ AM3TW-2407DZ AM3TW-2409DZ AM3TW-2412DZ AM3TW-2415DZ AM3TW-2418DZ
www.aimtec.com F 051e R12.F
Input Voltage (V) 9-36 9-36 9-36 9-36 9-36 9-36 9-36
Tel: +1 514 620 2722 1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM3TW-Z 3 Watt | DC-DC Converter Models Dual output Model
Input Voltage (V)
Output Voltage (V)
Output Current max (mA)
Isolation (VDC)
Capacitive load, max ( F)
Efficiency (%)
AM3TW-2424DZ AM3TW-4803DZ AM3TW-4805DZ AM3TW-4807DZ AM3TW-4809DZ AM3TW-4812DZ AM3TW-4815DZ AM3TW-4818DZ AM3TW-4824DZ
9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72
±24 ±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24
±63 ±400 ±300 ±208 ±167 ±125 ±100 ±84 ±63
1500 1500 1500 1500 1500 1500 1500 1500 1500
±33 ±470 ±470 ±100 ±100 ±68 ±68 ±33 ±33
80 76 81 78 82 81 82 81 81
AM3TW-2403DH35Z AM3TW-2405DH35Z AM3TW-2407DH35Z AM3TW-2409DH35Z AM3TW-2412DH35Z AM3TW-2415DH35Z AM3TW-2418DH35Z AM3TW-2424DH35Z AM3TW-4803DH35Z AM3TW-4805DH35Z AM3TW-4807DH35Z AM3TW-4809DH35Z AM3TW-4812DH35Z AM3TW-4815DH35Z AM3TW-4818DH35Z AM3TW-4824DH35Z
9-36 9-36 9-36 9-36 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 18-72 18-72 18-72 18-72
±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24 ±3.3 ±5 ±7.2 ±9 ±12 ±15 ±18 ±24
±400 ±300 ±208 ±167 ±125 ±100 ±84 ±63 ±400 ±300 ±208 ±167 ±125 ±100 ±84 ±63
3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500 3500
±470 ±470 ±100 ±100 ±68 ±68 ±33 ±33 ±470 ±470 ±100 ±100 ±68 ±68 ±33 ±33
76 79 78 79 80 80 81 80 76 81 78 82 81 82 81 81
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Input Specifications Parameters Voltage range
Nominal
Typical
24 48
9-36 18-72 π (Pi) Network
Filter Turn on Transient process time Start up time Absolute Maximum Rating
Maximum
VDC 350
24 Vin 48 Vin
Peak Input Voltage time
Units
500 -0.7-40 -0.7-80 100
ms ms VDC ms
Isolation Specifications Parameters Tested voltage Resistance Capacitance
Conditions
Typical
3 sec
Rated
Units
1500 and 3500
VDC MOhm pF
Maximum
Units
> 1000 470
Output Specifications Parameters Voltage accuracy Voltage balance (Dual output) Short Circuit protection Short circuit restart Line voltage regulation (Single) www.aimtec.com F 051e R12.F
Conditions Continuous Automatic LL-HL
Typical ±1 ±1
% %
±0.5
%
Tel: +1 514 620 2722 2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM3TW-Z 3 Watt | DC-DC Converter Output Specifications (continued) Parameters Line voltage regulation (Dual) Load voltage regulation (Single) Load voltage regulation (Single) 3.3V output model Load voltage regulation (Dual) Load voltage regulation (Dual) ±3.3V output model Temperature coefficient Ripple & Noise Rising time
Conditions
Typical
LL-HL Load: 10…100%
±0.5 ±0.5
Maximum
Units % %
Load: 10…100%
±1.5
%
Load: 10…100%
±0.5
%
Load: 10…100%
±1.5
%
0…20MHz
±0.02 60 10
%/oC mV p-p ms
General Specifications Parameters
Conditions
Typical
Switching frequency Operating temperature Storage temperature Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF
100% load Full Load without Derating
250 -40 to +85 -40 to +125
Maximum
Units
100
KHz o C o C o C
Free air convection Non condensing
% 90 Nickel-coated copper g 21 Tolerance ±0.5 mm or ±0.02 inches 1.28 x 0.84 x 0.41 inches 32.25 x 21.35 x 10.50 mm >1 222 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Pin Out Specifications Pin 1 2 3 9 10 11 12/13 14 15 16 22 23 24
1500VDC Dual
Single
Dual
+V Input N.C. N.C. No pin -V Output +V Output -V Input +V Output -V Output No pin N.C. N.C. +V Input
+V Input -V Output Common No pin Common +V Output -V Input +V Output Common No pin Common -V Output +V Input
No pin -V Input -V Input No Pin No pin N.C. No pin +V Output No pin -V Output +V Input +V Input No pin
No pin -V Input -V Input Common No pin -V Output No pin +V Output No pin Common +V Input +V Input No pin
www.aimtec.com F 051e R12.F
3500VDC
Single
Tel: +1 514 620 2722 3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AM3TW-Z 3 Watt | DC-DC Converter Dimensions
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com F 051e R12.F
Tel: +1 514 620 2722 4 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only