Transcript
Series AMEOC40-MAZ 40 Watt | AC-DC and DC-DC Converter FEATURES:
4000VAC I/O isolation Operating temperature: -40°C to +85°C Over load, Over voltage, Short circuit protection Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC
Energy star compliant RoHS compliant Low ripple and noise CE, cULus, CB approvals
CB
Models Single output Model
Input Voltage (VAC/Hz)
Input Voltage (VDC)
AMEOC40-3.3SMAZ AMEOC40-5SMAZ AMEOC40-12SMAZ AMEOC40-15SMAZ AMEOC40-24SMAZ
90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440
120-370 120-370 120-370 120-370 120-370
Model
Input Voltage (VAC/Hz)
Input Voltage (VDC)
AMEOC40-5DMAZ AMEOC40-12DMAZ AMEOC40-15DMAZ AMEOC40-24DMAZ
90-264/47-440 90-264/47-440 90-264/47-440 90-260/47-440
120-370 120-370 120-370 120-370
Output Voltage (V)
Output Current max (A)
3.3 5 12 15 24
8 8 3.33 2.66 1.66
Efficiency (%) 78 82 84 83 82
Models Dual output Output Voltage (V)
Output Current max (A)
±5 ±12 ±15 ±24
±4 ±1.66 ±1.33 ±0.835
Efficiency (%) 80 85 82 77
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Input Specifications Parameters
Conditions
Typical
Maximum
115 VAC 230 VAC 115 VAC 230 VAC
3.15 <0.5 <0.8 117
1000 530 25 50 150
Conditions
Typical
Maximum
(LL-HL) 0-100% load single 0-100% load dual 25% load - 1st out, 100% load – 2nd out Depending of the model 25% load Step 20MHz bandwidth 115VAC
±2 ±0.5 ±1 ±2 ±5 470-23 000 ±2 50 29 0
Current Inrush current <2ms Leakage current External fuse Input dissipation
Recommended slow blow type No load; 115VAC No load; 264VAC
Start-up time
Units mA A µA A W ms
Output Specifications Parameters Voltage accuracy Line regulation Load regulation Cross regulation Maximum Capacitive load Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current
Units % % % % µF % of Vout mV p-p ms % of Max
*Ripple & Noise measured with 0.1 F M/C and 1 F E/C
www.aimtec.com F 052e R7.G
Tel: +1 514 620 2722 1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AMEOC40-MAZ 40 Watt | AC-DC and DC-DC Converter Isolation Specifications Parameters
Conditions
Tested I/O voltage Isolation Resistance
Typical
3 sec
Rated
Units
4000
VAC M
>1000
General Specifications Parameters
Conditions
Switching frequency Over current protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Weight Dimensions (L X H X W) MTBF
Typical 47 110 Zener diode clamp Hiccup mode, indefinite Auto recovery -40 - +85
Auto recovery
With derating above 55ºC
Maximum
Units
140 110
KHz % %
o
C C o C % / oC o
100 -40 to +95 0.02 Free air convection Non condensing
95
% RH g
145 4.92 x 2.32 x 1.02 inches / 125 x 59 x 26mm > 800 000 hrs (MIL-HDBK -217F, t=+25oC)
Environment Approval Test
Shock
Vibration
Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation
Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis)
Safety Specifications Parameters Agency approvals
Standards
www.aimtec.com F 052e R7.G
cULus, CE, CB Scheme Medical Electrical Equipment Information technology Equipment Harmonic Current Emissions EMI - Conducted and radiated emission Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity
IEC\EN\UL 60601-1, CSA-C22.2 No. 601.1-M90 EN 60950-1:2006+A11:2009 IEC/EN 61000-3-2, (EN60555-2) EN55011, class B IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11
Tel: +1 514 620 2722 2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AMEOC40-MAZ 40 Watt | AC-DC and DC-DC Converter Pin Out Specifications Pin
Single
Dual
1 2 3 4 5 6
AC Input (L) AC Input (N) +V Output -V Output N.C. N.C.
AC Input (L) AC Input (N) +V Output Common Common -V Output
N.C.: Not Connected
Dimensions 59.00 (2.32)
59.00 (2.32)
52.00 (2.05)
1
2
3.50 (0.14)
118.00 (4.65)
125.00 (4.90)
AC Input Connector
3.50 (0.14)
Bottom View
www.aimtec.com F 052e R7.G
DC Output Connector
Tel: +1 514 620 2722 3 of 4
3 4 5 6 Top View
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AMEOC40-MAZ 40 Watt | AC-DC and DC-DC Converter
Output Power (%)
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com F 052e R7.G
Tel: +1 514 620 2722 4 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only