Series AMEPR30D-AZ up to 2A | AC-DC LED driver FEATURES:
AC-DC Constant current LED Driver Input range 90-264VAC/47-440Hz High Efficiency up to 84% Operating temperature -20 to 80°C Total Harmonic Distortion 20%
Over Temperature Protection IP67 Case Active PFC with TRIAC dimmable SCP, Over Load Protection
Models Single output Model
Max Output Power (W)
Output Voltage Range (V)
No Load Output Voltage (V max.)
35 29.4 25.6 36 30 33.6 30
36-50 32-42 24-36 24-36 12-24 12-24 8-15
64 54 52 52 34 34 23
AMEPR30D-5070AZ AMEPR30D-4270AZ AMEPR30D-3670AZ AMEPR30D-36100AZ AMEPR30D-24125AZ AMEPR30D-24140AZ AMEPR30D-15200AZ
Output Current (A)
Input Voltage (VAC/Hz)
Input Voltage (VDC)
Efficiency (%)
0.7 0.7 0.7 1 1.25 1.4 2
90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440
120-370 120-370 120-370 120-370 120-370 120-370 120-370
85 84 83 84 82 83 81
Exceeding the maximum output power will permanently damage the converter Model Nomenclature Options: Add Suffix “-UD” Add Suffix “-110D” Add Suffix “-220D”
Universal AC input 90-264VAC(no TRIAC dimming with this option),IP20 AC input 90-135VAC, IP20 AC input 180-264VAC, IP20
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Input Specifications Parameters Inrush current <2ms Leakage current AC current Power Factor
Conditions
Typical
115VAC 230VAC 115VAC 230VAC 115VAC 230VAC 115VAC 230VAC
10 20 0.2 0.25 0.35 0.15
Maximum
Units A mA A
0.9 0.9 250V/1A
External fuse Start up time
200
ms
Output Specifications Parameters
Conditions
Typical
Current accuracy ±5 Line regulation LL-HL ±7 Load regulation 0-100% load ±5 20MHz Bandwidth 1-3 Ripple & Noise Hold-up time 1 Minimum Load Voltage See the models table Tested with 0.1µF (M/C) or (C/C) and 47µF (E/C) parallel capacitors at the end.
www.aimtec.com F 052.1e R3.A
Tel: +1 514 620 2722 1 of 4
Maximum
Units % % % V p-p ms
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AMEPR30D-AZ up to 2A | AC-DC LED driver Isolation Specifications Parameters
Conditions
Tested I/O voltage Isolation Resistance
Typical
3sec
Maximum
Units
3000
VAC M
>1000
General Specifications Parameters
Conditions
Switching frequency Over load protection Over voltage protection Short circuit protection Short circuit restart Over temperature protection Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Wires Weight Dimensions (L X H X W) MTBF
Typical
Maximum
65 110% of Iout 110% of Vout Continuous Auto recovery >105°C -20 to +80
With derating over 55°C
KHz
o
100 -40 to +95 ±0.02 Free air convection 95 Plastic UL1015 20AWG * 10CM 200 133x33x30mm >400,000 hrs (MIL-HDBK-217F at +25°C)
Units
C C o C % / oC o
% RH
g
Environment Approval Test
Shock
Vibration
Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation
Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis)
Safety Specifications Parameters Agency approvals Standards
www.aimtec.com F 052.1e R3.A
cULus, CE, CB (all pending) EN61347, IEC62384, UL8750, UL60950-1, EN55015
Tel: +1 514 620 2722 2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AMEPR30D-AZ up to 2A | AC-DC LED driver Dimensions
Temperature Graph Free Air Convection 55 º C
100 80
Safe Operating Area
60 40 20 0 - 25
- 20
0
20
40
60
Ambient Temperature
www.aimtec.com F 052.1e R3.A
80 ºC
100
Tel: +1 514 620 2722 3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only
Series AMEPR30D-AZ up to 2A | AC-DC LED driver Triac Dimming Feature
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com F 052.1e R3.A
Tel: +1 514 620 2722 4 of 4
Toll free: + 1 888 9 AIMTEC (924 6832) North America only