APPLIED POWER SYSTEMS, INC. CAP6637A AC-DC Open Loop Converter CAP6637A AC-DC Open Loop Converter Description: The CAP6637 is a three-phase AC to DC Converter assembly. The assembly includes the three-phase SCR converter bridge, a free wheeling diode, the thermal management system, a BAP1950 SCR phase control gate firing board, an R-CMOV snubber for each SCR and all bus work. It is rated at 125 Amps output and up to 660 volts AC input at 50 or 60 Hz. Typical use for the CAP6637 is as an ACDC controller for OEM equipment; boost charger power supplies for rail and many other applications. The CAP6636 can be voltage limited and current regulated for precision DC applications. Contact APS for higher power system requirements. Specifications: Input Parameter Ambient Temperature Input AC Voltage Frequency Min -40 50 47 Typ Min Typ 150 480 60 Max 50 660 77 Units °C Volts Hz SCR Modules Parameter Average Current One cycle peak current Blocking Voltage Module Isolation Voltage dV/dt dI/dt (non-repetitive) 124 Charlotte Avenue Hicksville, NY 11801 3,500 1,000 300 Ph: 516.935.2230 Fax: 516.935.2603 Max Units 175 Amps 4,000 Amps 1,600 Volts Volts V/µs A/µs Website: www.appliedps.com Page 1 of 5 Rev.: 050807-01 APPLIED POWER SYSTEMS, INC. CAP6637A AC-DC Open Loop Converter BAP1950 Gate Firing Board Power Requirements Parameter Input Voltage1 Power rating Min 100 Typ 115 Max Units 130 Vac 24 VA Min 0 0 Typ Max Units 900 Vdc 125 Amps Hz Converter Output Parameter Output Voltage Current Ripple Frequency (at 60 Hz) 360 Isolation The low level signal inputs are isolated from the high level DC output and AC input in the following manner: Isolation AC Supply AC Supply and DC Load BAP1950 Input Power 1 Isolation Method The AC supply is sensed through a resistor voltage divider with a 1meg isolation resistance on each phase. 5,000Vac (60 sec.) – rating from gate pulse transformers 2500Vac (1 min.) from input transformer on board. Other input voltages are available. Please consult APS for further information. 124 Charlotte Avenue Hicksville, NY 11801 Ph: 516.935.2230 Fax: 516.935.2603 Website: www.appliedps.com Page 2 of 5 Rev.: 050807-01 APPLIED POWER SYSTEMS, INC. CAP6637A AC-DC Open Loop Converter J3 Connector Pin Signal Name Color 1 2 3 4 24 VAC 24 VAC 24 VDC Fast Turn off 5 Master/Slave 6 7 8 15 VDC 5 VDC GND 9 Inhibit Enunciate 10 Delay Angle Control White 11 GND Black 12 Soft Start/Stop Blue Yellow Red Black Description From secondary winding of T2. 250mA available for customer use. From secondary winding of T2. 250mA available for customer use. 250mA available for customer use. Shorting this signal to pin 6 or 7 enables gate pulses. Letting it float will disable the gating signals within 20uS. This pin is used when 2 or more boards are configured as Master/Slaves. 50mA available for customer use. 50mA available for customer use. Reference for AP1950 control circuitry, including Delay Angle Control. Therefore, it must be tied to the reference of a customer provided Delay Angle Control signal. Normally low (through a 1K resistor). Transitions high in a Fast Turn off or in an out of phase lock condition. 0 to 5V analog input to control the delay angle. 0V Max Delay Angle (corresponding to minimum output voltage); 5V Min Delay Angle (corresponding to maximum output voltage). Reference for AP1950 control circuitry, including Delay Angle Control. Therefore, it must be tied to the reference of a customer provided Delay Angle Control signal. When this signal transitions from a contact closure to GND (pin 11 or 8) to an open circuit, the delay angle ramps down from maximum to the programmed value. If control power is applied to the AP1950, a transition from an open circuit to a contact closure to GND, the delay angle ramps up from the programmed value to the max value (minimum output voltage). Signals with an assigned color are provided in the connector. If additional signals are to be used, the AMP contact part number is 350550-1 and the part number for the recommended crimping tool from AMP is 91500-1. If a potentiometer will be used to control the delay angle, use the setup below. Customer provided Potentiometer 124 Charlotte Avenue Hicksville, NY 11801 Ph: 516.935.2230 Fax: 516.935.2603 Website: www.appliedps.com Page 3 of 5 Rev.: 050807-01 APPLIED POWER SYSTEMS, INC. CAP6637A AC-DC Open Loop Converter Schematic of AC-DC Open Loop Converter 124 Charlotte Avenue Hicksville, NY 11801 Ph: 516.935.2230 Fax: 516.935.2603 Website: www.appliedps.com Page 4 of 5 Rev.: 050807-01 APPLIED POWER SYSTEMS, INC. 124 Charlotte Avenue CAP6637 AC-DC Open Loop Converter Hicksville, NY 11801 Ph: 516.935.2230 Fax: 516.935.2603 Website: www.appliedps.com Page 5 of 5 Rev.: 010307-01