DATA SHEET DD02-999LF: 650 MHz–3 GHz Directional Detector Features Pin Out ฀฀Frequency฀coverage:฀650฀MHz฀to฀3฀GHz ฀Low฀insertion฀loss:฀0.2฀dB฀typ.฀up฀to฀2฀GHz l฀Directivity:฀23฀dB฀typ. l฀฀฀Small฀outline฀SC-88฀(6-Lead฀SC-70) l฀฀Built-in฀temperature฀compensating฀diode l฀฀฀Low฀cost฀for฀high-volume฀handset฀applications l฀฀ Lead฀(Pb)-free฀and฀RoHS-compliant฀MSL-1฀@฀260฀°C฀ per฀JEDEC฀J-STD-020 l RF฀In 5 DC฀Bias/AC฀GND 4 3 Temp฀Comp฀Out 2 DC฀Bias/AC฀GND 6 RF฀Out 1 l Detected฀Out Description The฀DD02-999LF฀directional฀detector฀is฀designed฀to฀operate฀from฀ 650฀MHz฀to฀3฀GHz.฀It฀contains฀a฀high-directivity฀directional฀ coupler,฀the฀coupled฀arm฀of฀which฀drives฀a฀GaAs฀Schottky฀ detector฀diode.฀฀It฀also฀contains฀an฀identical฀GaAs฀Schottky฀diode฀ used฀for฀temperature฀compensation.฀This฀part฀is฀packaged฀in฀the฀ miniature฀SC-88฀package.฀The฀DD02-999LF฀is฀packaged฀in฀the฀ lead฀(Pb)-free฀SC-88฀package฀and฀is฀fully฀compliant฀with฀current฀ RoHS฀requirements.฀ The฀DD02-999LF฀provides฀detection฀of฀the฀input฀signal฀amplitude฀ only,฀by฀virtue฀of฀the฀directivity฀of฀the฀on-chip฀directional฀coupler.฀฀The฀sensitivity฀of฀the฀detector฀diode฀is฀improved฀through฀ the฀application฀of฀an฀external฀5฀µA฀(nominal)฀forward฀bias฀current฀ produced฀by฀an฀external฀1฀V฀(nominal)฀voltage฀source.฀This฀bias฀ current฀is฀also฀applied฀to฀the฀temperature฀compensation฀diode.฀฀ Temperature฀compensation฀of฀the฀detected฀output฀voltage฀can฀be฀ accomplished฀by฀subtracting฀the฀output฀voltage฀from฀the฀temperature฀compensation฀Schottky฀diode,฀which฀is฀thermally฀coupled฀ to฀the฀detector฀Schottky฀diode฀via฀their฀common฀substrate,฀from฀ the฀detected฀output฀voltage. This฀part฀is฀rated฀to฀operate฀from฀-40฀°C฀to฀85฀°C.฀฀ An฀evaluation฀board฀is฀available฀upon฀request. NEW BUY NOW Skyworks฀offers฀lead฀(Pb)-free,฀RoHS฀(Restriction฀of฀ Hazardous฀Substances)-compliant฀packaging. Innovation to GoTM Now available for purchase online. Skyworks฀Solutions,฀Inc.฀฀•฀฀Phone฀[781]฀376-3000฀฀•฀฀Fax฀[781]฀376-3100฀฀•฀฀[email protected]฀฀•฀฀www.skyworksinc.com ฀ 200035฀Rev.฀F฀฀•฀฀Skyworks฀Proprietary฀Information฀฀•฀฀Products฀and฀Product฀Information฀are฀Subject฀to฀Change฀Without฀Notice.฀฀•฀฀December฀4,฀2008 1 Data฀Sheet฀฀•฀฀DD02-999LF Electrical Specifications at 25 °C TA = 25 C, Z0 = 50 W, PIN = 10 dBm, VBIAS = 1 V at pins 2 and 5, RLOAD = 100 kW, unless otherwise noted ฀ Parameter฀ Frequency฀ Min.฀ typ.฀ Max.฀ Unit Detected฀output฀voltage฀@฀10฀dBm฀ ฀ ฀ ฀ ฀ ฀ ฀ 0.8–1.2฀GHz฀ 1.8–2.0฀GHz฀ 60฀ 130฀ 80฀ 160฀ 105฀ 190฀ mV mV Insertion฀loss฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ 0.8–1.2฀GHz฀ 1.8–2.0฀GHz฀ ฀ ฀ 0.1฀ 0.2฀ 0.2฀ 0.3฀ dB dB Input฀return฀loss฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ 0.8–1.2฀GHz฀ 1.8–2.0฀GHz฀ ฀ ฀ 30฀ 25฀ 22฀ 20฀ dB dB Output฀return฀loss฀ ฀ ฀ ฀ ฀ ฀ ฀ ฀ 0.8–1.2฀GHz฀ 1.8–2.0฀GHz฀ ฀ ฀ 30฀ 25฀ 22฀ 20฀ dB dB Directivity฀ ฀ ฀ ฀ ฀ ฀ 0.8–1.2฀GHz฀ 1.8–2.0฀GHz฀ 17฀ 16฀ 20฀ 13฀ ฀ ฀ dB dB ฀ ฀ RF฀power฀off฀ ฀ 200฀ ฀ µV ฀ ฀ Schottky฀noise฀voltage฀(1฀MHz฀bandwidth)฀ Schottky฀diode฀DC฀voltage฀ ฀ ฀ RF฀power฀off฀ ฀ 510฀ ฀ mV DC฀offset฀voltage฀ ฀ ฀ ฀ RF฀power฀off฀ -5฀ 0฀ 5฀ mV Video฀resistance฀ ฀ ฀ ฀ RF฀power฀off฀ ฀ 7500฀ ฀ W Conditions:฀10฀dBm฀input฀power,฀1฀V฀applied฀to฀Pin฀2฀and฀5฀(See฀test฀circuit). All฀data฀was฀taken฀with฀RLOAD฀=฀100฀kW. Detected฀output฀voltage฀is฀the฀difference฀between฀VREF฀and฀VDET.฀A฀digital฀voltmeter฀was฀used฀ as฀a฀differential฀amplifier. Skyworks฀Solutions,฀Inc.฀฀•฀฀Phone฀[781]฀376-3000฀฀•฀฀Fax฀[781]฀376-3100฀฀•฀฀[email protected]฀฀•฀฀www.skyworksinc.com 2฀ December฀4,฀2008฀฀•฀฀Skyworks฀Proprietary฀Information฀฀•฀฀Products฀and฀Product฀Information฀are฀Subject฀to฀Change฀Without฀Notice.฀฀•฀฀200035฀Rev.฀F Data฀Sheet฀฀•฀฀DD02-999LF Typical Performance Data TA = 25 C, Z0 = 50 W, unless otherwise noted 0 0 -5 -0.25 Return฀Loss฀(dB) -10 Loss฀(dB) -0.50 -0.75 -1.00 -25 -30 -35 Input฀Return฀Loss Output฀Return฀Loss -45 -1.50 0.5 1.0 1.5 2.0 2.5 -50 0.5 3.0 1.0 1.5 2.0 2.5 Frequency฀(GHz) Frequency฀(GHz) Insertion฀Loss฀vs.฀Frequency Return฀Loss฀vs.฀Frequency 1.2 3.0 5.0 20฀dBm 4.5 0.8 0.6 15฀dBm 0.4 10฀dBm 0.2 Detected฀Voltage฀(V) 1.0 Detected฀Voltage฀(V) -20 -40 -1.25 4.0 35฀dBm 3.5 3.0 2.5 30฀dBm 2.0 1.5 1.0 25฀dBm 0.5 5฀dBm 0 0 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 Frequency฀(GHz) Frequency฀(GHz) Differential฀Detected฀Voltage vs.฀Frequency฀and฀Power Differential฀Detected฀Voltage vs.฀Frequency฀&฀Power 3.0 0.10 0.09 2.5 0.08 2.0 1.5 25฀°C 1.0 85฀°C 0.5 ฀-40฀°C 0 0 3 6 9 12 15 18 21 24 27 30 33 36 Detected฀Voltage฀(V) Detected฀Voltage฀(V) -15 0.07 0.06 0.05 0.04 0.03 85฀°C 0.02 25฀°C 0.01 ฀-40฀°C 0 0 2 4 6 8 10 Power฀(dBm) Power฀(dBm) Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀900฀Mhz Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀900฀Mhz 12 Skyworks฀Solutions,฀Inc.฀฀•฀฀Phone฀[781]฀376-3000฀฀•฀฀Fax฀[781]฀376-3100฀฀•฀฀[email protected]฀฀•฀฀www.skyworksinc.com ฀ 200035฀Rev.฀F฀฀•฀฀Skyworks฀Proprietary฀Information฀฀•฀฀Products฀and฀Product฀Information฀are฀Subject฀to฀Change฀Without฀Notice.฀฀•฀฀December฀4,฀2008 3 0.59 2.75 0.54 2.50 0.49 2.25 Detected฀Voltage฀(V) Detected฀Voltage฀(V) Data฀Sheet฀฀•฀฀DD02-999LF 0.44 0.39 25฀°C 0.34 0.29 -40฀°C 0.24 0.19 85฀°C 0.09 12 14 16 1.50 85฀°C 1.25 1.00 -40฀°C 0.50 18 20 24 24 22 26 28 30 32 34 Power฀(dBm) Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀900฀Mhz Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀900฀Mhz 0.25 4.0 3.0 25฀°C 2.0 Detected฀Voltage฀(V) 5.0 85฀°C 1.0 0.20 0.15 25฀°C 0.10 85฀°C 0.05 ฀-40฀°C ฀-40฀°C 0 0 3 6 9 0 0 12 15 18 21 24 27 30 33 36 2 4 6 8 10 12 Power฀(dBm) Power฀(dBm) Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀1900฀Mhz Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀1900฀Mhz 1.2 5.5 1.1 5.0 Detected฀Voltage฀(V) 1.0 0.9 0.8 25฀°C 0.7 0.6 85฀°C 0.5 0.4 -40฀°C 0.3 12 14 16 18 4.5 4.0 3.5 25฀°C 3.0 85฀°C 2.5 2.0 -40฀°C 1.5 0.2 20 22 24 1.0 24 26 28 30 32 34 36 Power฀(dBm) Power฀(dBm) Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀1900฀Mhz Differential฀Detected฀Voltage฀vs. Power฀and฀Temperature฀@฀1900฀Mhz Skyworks฀Solutions,฀Inc.฀฀•฀฀Phone฀[781]฀376-3000฀฀•฀฀Fax฀[781]฀376-3100฀฀•฀฀[email protected]฀฀•฀฀www.skyworksinc.com 4฀ 36 Power฀(dBm) 6.0 Detected฀Voltage฀(V) 25฀°C 1.75 0.75 0.14 Detected฀Voltage฀(V) 2.00 December฀4,฀2008฀฀•฀฀Skyworks฀Proprietary฀Information฀฀•฀฀Products฀and฀Product฀Information฀are฀Subject฀to฀Change฀Without฀Notice.฀฀•฀฀200035฀Rev.฀F Data฀Sheet฀฀•฀฀DD02-999LF Evaluation Board Layout Absolute Maximum Ratings ฀฀ RF฀In DD0*-92 100฀pF 1.8฀k ฀ DC฀bias฀current฀฀ VDET 220฀pF Characteristic฀ ฀ Incident฀power฀(CW)฀฀ @฀SWR฀=฀2฀max.฀ ฀฀ 100฀k 100฀pF DD2 Value 4฀W฀@฀<฀1฀GHz฀ 2฀W฀@฀1–2.5฀GHz ฀ 10฀mA ฀ Operating฀temperature฀ -40฀°C฀to฀+85฀°C ฀ Storage฀temperature฀ -65฀°C฀to฀+150฀°C ฀ ESD฀ ฀ 200฀V Performance฀is฀guaranteed฀only฀under฀the฀conditions฀listed฀in฀the฀specifications฀table฀and฀is฀ not฀guaranteed฀under฀the฀full฀range(s)฀described฀by฀the฀Absolute฀Maximum฀specifications. Exceeding฀any฀of฀the฀absolute฀maximum/minimum฀specifications฀may฀result฀in฀permanent฀ damage฀to฀the฀device฀and฀will฀void฀the฀warranty. 100฀k 22 nH Bias฀In VREF SK39374 Rev฀2 1.8฀k RF฀Out CAUTION: Although this device is designed to be as robust as possible, ESD (Electrostatic Discharge) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions must be employed at all times. Application Circuit SC-88 (6-Lead SC-70) RF฀In 100฀pF 22฀nH + – 6 5 0.079฀(2.00฀mm) ±฀0.008฀(0.20฀mm) 100฀k 1.8฀k 4 Detect฀Out VDET 150฀pF Differential Amplifier 1฀V Bias VREF 1 3 2 1.0฀V RF฀Out 0.087฀(2.20฀mm) ±฀0.008฀(0.20฀mm) 0.049฀(1.25฀mm) ±฀0.004฀(0.10฀mm) Pin฀1฀Indicator 0.009฀(0.23฀mm)฀ Ref. 0.035฀(0.90฀mm) ±฀0.004฀(0.10฀mm) 1.8฀k 100฀k 0.0256฀(0.65฀mm) BSC 100฀pF 0.002฀(0.005฀mm) ±฀0.002฀(0.005฀mm) Differential฀amplifier฀not฀included฀on฀test฀board. 0.010฀(0.25฀mm) ±฀0.006฀(0.15฀mm) 0.0055 (0.14฀mm) ±฀0.0015 (0.04฀mm) 0.037฀(0.95฀mm) ±฀0.006฀(0.15฀mm) 0.008฀(0.20฀mm) ±฀0.004฀(0.10฀mm) Recommended Solder Reflow Profiles Refer to the “Recommended Solder Reflow Profile” Application Note. Tape and Reel Information Refer to the “Discrete Devices and IC Switch/Attenuators Tape and Reel Package Orientation” Application Note. Skyworks฀Solutions,฀Inc.฀฀•฀฀Phone฀[781]฀376-3000฀฀•฀฀Fax฀[781]฀376-3100฀฀•฀฀[email protected]฀฀•฀฀www.skyworksinc.com ฀ 200035฀Rev.฀F฀฀•฀฀Skyworks฀Proprietary฀Information฀฀•฀฀Products฀and฀Product฀Information฀are฀Subject฀to฀Change฀Without฀Notice.฀฀•฀฀December฀4,฀2008 5 Data฀Sheet฀฀•฀฀DD02-999LF Copyright฀©฀2002,฀2003,฀2004,฀2005,฀2006,฀2007,฀2008,฀Skyworks฀Solutions,฀Inc.฀All฀Rights฀Reserved. Information฀in฀this฀document฀is฀provided฀in฀connection฀with฀Skyworks฀Solutions,฀Inc.฀(“Skyworks”)฀products฀or฀services.฀These฀materials,฀including฀the฀information฀contained฀herein,฀are฀provided฀ by฀Skyworks฀as฀a฀service฀to฀its฀customers฀and฀may฀be฀used฀for฀informational฀purposes฀only฀by฀the฀customer.฀Skyworks฀assumes฀no฀responsibility฀for฀errors฀or฀omissions฀in฀these฀materials฀or฀the฀ information฀contained฀herein.฀Skyworks฀may฀change฀its฀documentation,฀products,฀services,฀specifications฀or฀product฀descriptions฀at฀any฀time,฀without฀notice.฀Skyworks฀makes฀no฀commitment฀to฀ update฀the฀materials฀or฀information฀and฀shall฀have฀no฀responsibility฀whatsoever฀for฀conflicts,฀incompatibilities,฀or฀other฀difficulties฀arising฀from฀any฀future฀changes.฀ No฀license,฀whether฀express,฀implied,฀by฀estoppel฀or฀otherwise,฀is฀granted฀to฀any฀intellectual฀property฀rights฀by฀this฀document.฀Skyworks฀assumes฀no฀liability฀for฀any฀materials,฀products฀or฀ information฀provided฀hereunder,฀including฀the฀sale,฀distribution,฀reproduction฀or฀use฀of฀Skyworks฀products,฀information฀or฀materials,฀except฀as฀may฀be฀provided฀in฀Skyworks฀Terms฀and฀ Conditions฀of฀Sale.฀ THE฀MATERIALS,฀PRODUCTS฀AND฀INFORMATION฀ARE฀PROVIDED฀“AS฀IS”฀WITHOUT฀WARRANTY฀OF฀ANY฀KIND,฀WHETHER฀EXPRESS,฀IMPLIED,฀STATUTORY,฀OR฀OTHERWISE,฀INCLUDING฀FITNESS฀FOR฀A฀ PARTICULAR฀PURPOSE฀OR฀USE,฀MERCHANTABILITY,฀PERFORMANCE,฀QUALITY฀OR฀NON-INFRINGEMENT฀OF฀ANY฀INTELLECTUAL฀PROPERTY฀RIGHT;฀ALL฀SUCH฀WARRANTIES฀ARE฀HEREBY฀EXPRESSLY฀ DISCLAIMED.฀SKYWORKS฀DOES฀NOT฀WARRANT฀THE฀ACCURACY฀OR฀COMPLETENESS฀OF฀THE฀INFORMATION,฀TEXT,฀GRAPHICS฀OR฀OTHER฀ITEMS฀CONTAINED฀WITHIN฀THESE฀MATERIALS.฀SKYWORKS฀ SHALL฀NOT฀BE฀LIABLE฀FOR฀ANY฀DAMAGES,฀INCLUDING฀BUT฀NOT฀LIMITED฀TO฀ANY฀SPECIAL,฀INDIRECT,฀INCIDENTAL,฀STATUTORY,฀OR฀CONSEQUENTIAL฀DAMAGES,฀INCLUDING฀WITHOUT฀LIMITATION,฀ LOST฀REVENUES฀OR฀LOST฀PROFITS฀THAT฀MAY฀RESULT฀FROM฀THE฀USE฀OF฀THE฀MATERIALS฀OR฀INFORMATION,฀WHETHER฀OR฀NOT฀THE฀RECIPIENT฀OF฀MATERIALS฀HAS฀BEEN฀ADVISED฀OF฀THE฀ POSSIBILITY฀OF฀SUCH฀DAMAGE. Skyworks฀products฀are฀not฀intended฀for฀use฀in฀medical,฀lifesaving฀or฀life-sustaining฀applications,฀or฀other฀equipment฀in฀which฀the฀failure฀of฀the฀Skyworks฀products฀could฀lead฀to฀personal฀injury,฀ death,฀physical฀or฀environmental฀damage.฀Skyworks฀customers฀using฀or฀selling฀Skyworks฀products฀for฀use฀in฀such฀applications฀do฀so฀at฀their฀own฀risk฀and฀agree฀to฀fully฀indemnify฀Skyworks฀for฀any฀ damages฀resulting฀from฀such฀improper฀use฀or฀sale. Customers฀are฀responsible฀for฀their฀products฀and฀applications฀using฀Skyworks฀products,฀which฀may฀deviate฀from฀published฀specifications฀as฀a฀result฀of฀design฀defects,฀errors,฀or฀operation฀of฀ products฀outside฀of฀published฀parameters฀or฀design฀specifications.฀Customers฀should฀include฀design฀and฀operating฀safeguards฀to฀minimize฀these฀and฀other฀risks.฀Skyworks฀assumes฀no฀liability฀for฀ applications฀assistance,฀customer฀product฀design,฀or฀damage฀to฀any฀equipment฀resulting฀from฀the฀use฀of฀Skyworks฀products฀outside฀of฀stated฀published฀specifications฀or฀parameters.฀ Skyworks,฀the฀Skyworks฀symbol,฀“Breakthrough฀Simplicity”฀and฀“Innovation฀to฀Go”฀are฀trademarks฀or฀registered฀trademarks฀of฀Skyworks฀Solutions,฀Inc.,฀in฀the฀United฀States฀and฀other฀countries.฀Thirdparty฀brands฀and฀names฀are฀for฀identification฀purposes฀only,฀and฀are฀the฀property฀of฀their฀respective฀owners.฀Additional฀information,฀including฀relevant฀terms฀and฀conditions,฀posted฀at฀www.skyworksinc. com,฀are฀incorporated฀by฀reference.฀ Skyworks฀Solutions,฀Inc.฀฀•฀฀Phone฀[781]฀376-3000฀฀•฀฀Fax฀[781]฀376-3100฀฀•฀฀[email protected]฀฀•฀฀www.skyworksinc.com 6฀ December฀4,฀2008฀฀•฀฀Skyworks฀Proprietary฀Information฀฀•฀฀Products฀and฀Product฀Information฀are฀Subject฀to฀Change฀Without฀Notice.฀฀•฀฀200035฀Rev.฀F