Transcript
Plastic Optical Fiber (POF) Cables, Patch Cords and Plugs
DATA SHEET
Plastic Optical Fiber (POF) Cables, Patch Cords and Plugs
FEATURES •
Cost-effective, rugged optical links
•
Compatible with IEC 60793-2-40 Class A4a standard
•
Cable flameproof to UL grade VW-1
•
Cable available in reels for on-site installation, or for making complex harnesses
•
Cable suitable for use with Firecomms POF transceivers, including RedLink®, LC and OptoLock®.
•
LC plugs available for easy cable termination
•
Patch cords in a variety of convenient standard lengths
•
Compatible with Versatile Link connectors and fiber optic transmitter and receivers
APPLICATIONS •
Control links within high voltage electrical control equipment
•
Data communication where extreme immunity to EMI is required
•
Links between equipment that requires electrical isolation to be maintained
•
Rugged links in hostile environments
Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein.
DESCRIPTION Firecomms offers a range of high quality POF cables, LC plugs, and pre-assembled patch cords in both LC and RedLink® styles, suitable for use with the company’s range of transceivers and other industry-standard products. POF cable is delivered on reels for convenience when installing runs of cable into equipment or buildings, making harness assemblies, or making custom length patch cords in small quantities. Both single cable and twin (figure of eight) cable are available. Firecomms LC plugs may be assembled easily onto twin cable to prepare it for use with Firecomms LC transceivers. Firecomms patch cords are available in a convenient range of lengths for use with RedLink or Versatile Link transmitters and receivers, and LC transceivers.
POF Cables, Patch Cords and Plugs
DATA SHEET 2
SPECIFICATIONS
Table 1 BARE CABLE SPECIFICATIONS Parameter
Symbol
Min
Storage Temperature
T stg
Operating Temperature Minimum Bend Radius
Max
Unit
-40
+85
°C
T op
-40
+85
°C
R min
25
[1]
Repeat Bending Endurance
Typical
mm
10,000
Numerical Aperture
NA
0.5
α
Attenuation at 650 nm Tensile Stress Simplex/Duplex
0.19 70/140
UL Flame Resistant Rating
dB/m N
VW-1
Fiber Diameter, including Cladding
Dc
0.94
1
1.06
mm
Cable Diameter – Simplex
Dj
2.13
2.2
2.27
mm
Twin Cable – Minor Axis
Dj
2.13
2.2
2.27
mm
Twin Cable – Major Axis
Dm
4.3
4.4
4.5
mm
Jacket Material
Flame Resistant PE or PVC
Jacket Color
Black or Grey
Jacket Diameter Minor Axis
Major Axis
Optical Fibre
Jacket
FIGURE 1 Duplex POF cross section. Note: 1.
Repeat bending loss increment
B (90° bend in direction of minor axis, 25 mm radius, deadweight 500 g).
Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein.
POF Cables, Patch Cords and Plugs
DATA SHEET 3
SPECIFICATIONS (continued)
Table 2 LC PLUGS SPECIFICATIONS 8 GND
Parameter
Symbol
Vcc
Min 1 -40 2
Typical
Max
Unit
+85
°C
Storage Temperature
T stg
NP
Operating Temperature
T op
GND -40
3
+85
°C
Installation Temperature
TI
0 TTL (D+)
4
+70
°C
Retention Force, Connector to Transceiver
FR
5 GND
N
Insertion Force, Connector to Transceiver
FI
Durability, Mating Cycles
100 9 500
Standards Compliance
IEC 61754-20 Edition 2
Fixing Method
Crimp
FIGURE 2 LC POF plug.
Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein.
IC
12
N
POF Cables, Patch Cords and Plugs
DATA SHEET 4
SPECIFICATIONS (continued) 33.0 [1.300]
3.8 [0.150]
CRIMP RING
3.8 [0.150]
25.4 [1.000]
SIMPLEX LATCHING CONNECTOR
28.2 [1.110] 3.8 [0.150]
7.1 [0.280]
Ø3.8 [0.150]
5.8 [0.230]
SIMPLEX FRICTION CONNECTOR
7.4 [0.290]
DUPLEX CRIMP RING
4.57 [0.180]
10.2 [0.400]
10.2 [0.400]
DUPLEX CRIMP RING
4.57 [0.180]
11.0 [0.434] 12.2 [0.480] 32.0 [1.260]
32.0 [1.260]
38.1 [1.500]
38.1 [1.500]
DUPLEX FRICTION CONNECTOR
DUPLEX LATCHING CONNECTOR
FIGURE 3 RedLink plug.
Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein.
8.9 [0.350]
Ø3.8 [0.150]
5.8 [0.230]
7.4 [0.290]
5.1 [0.200]
19.1 [0.750]
Ø2.2 [0.087]
CRIMP RING
8.9 [0.350]
7.6 [0.300]
Ø3.8 [0.150]
28.2 [1.110]
POF Cables, Patch Cords and Plugs
DATA SHEET 5
SPECIFICATIONS (continued) Table 3 PATCH CORD SPECIFICATIONS Symbol
Min
Max
Unit
Storage Temperature
T stg
-40
Typical
+85
°C
Operating Temperature
T op
-40
+85
°C
Installation Temperature
TI
0
+70
°C
Tensile Force, LC Connector to Cable
FT
16
N
Tensile Force, Simplex RedLink Connector to Cable
FT
8.5
N
Tensile Force, Duplex RedLink Connector to Cable
FT
14
N
(6.25)
Parameter
Duplex - w/Latch
L
FIGURE 4 LC POF patch cords.
Simplex - No Latch
Simplex - w/Latch
(10.16)
Duplex - No Latch
Duplex - w/Latch L
FIGURE 5 RedLink patch cords. Note: Simplex RedLink patch cords have a blue plug at one end and a grey plug at the other end.
Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein.
POF Cables, Patch Cords and Plugs
DATA SHEET 6
ORDERING INFORMATION
Table 4 ORDERING INFORMATION Part Number
Name
Description
Versatile Link Cross Reference
FC-100-0SB
100m Reel Simplex POF Cable
Reel 0.5NA SI-POF simplex
N/A
FC-500-0SB
500m Reel Simplex POF Cable
Reel 0.5NA SI-POF simplex
N/A
FC-100-0DB
100m Reel Duplex POF Cable
Reel 0.5NA SI-POF duplex
N/A
FC-500-0DB
500m Reel Duplex POF Cable
Reel 0.5NA SI-POF duplex
N/A
FP-00C-LD0
LC Plug for POF
LC plug for POF
N/A
FG-00C-LZ0
LC Dust Cap
White dust cap to fit LC plug
N/A
FP-00C-VS0
RedLink Simplex Friction Plug, Grey
FP-00C-US0
RedLink Simplex Friction Plug, Blue
FP-00C-YS0
RedLink Simplex Latching Plug, Grey
FP-00C-XS0
RedLink Simplex Latching Plug, Blue
Blue latching simplex plug with crimp ring
HFBR-4513Z
FP-00C-RD0
RedLink Duplex Friction Plug
Duplex plug with crimp ring, no latch
HFBR-4506Z
FP-00C-SD0
RedLink Duplex Latching Plug
Duplex latching plug with crimp ring
HFBR-4516Z
FD-xxx-LDB
LC Duplex Patch Cord
FD-xxx-BSB
RedLink Simplex Patch Cord, Friction Plugs
FD-xxx-CSB
RedLink Simplex Patch Cord, Latching Plugs
FD-xxx-RDB
RedLink Duplex Patch Cord, Friction Plugs
FD-xxx-SDB
RedLink Duplex Patch Cord, Latching Plugs
Grey simplex plug with crimp ring, no latch Blue simplex plug with crimp ring, no latch Grey latching simplex plug with crimp ring
XXX m LC duplex patch cable 0.5NA SIPOF XXX m RedLink simplex patch cable with friction plug 0.5NA SI-POF XXX m RedLink simplex patch cable with latch plug 0.5NA SI-POF XXX m RedLink duplex patch cable with duplex friction plug 0.5NA SI-POF XXX m RedLink duplex patch cable with duplex latch plug 0.5NA SI-POF
HFBR-4501Z HFBR-4511Z HFBR-4503Z
N/A N/A N/A N/A N/A
The sequence-xxx in each part number should be replaced by one of the following standard lengths: Table 5 PART NUMBER LENGTH CODE Code
Length
30C
30 cm patch cord
01M
1 m patch cord
02M
2 m patch cord
05M
5 m patch cord
100
100 m reel
500
500 m reel
Firecomms Ltd. • 2200 Airport Business Park • Cork, Ireland • Ph +353 (21) 4547100 • Fax +353 (21) 4322657 • www.firecomms.com Copyright (c) 2013 Firecomms Ltd.