Preview only show first 10 pages with watermark. For full document please download

Datasheet For Fd-100

   EMBED


Share

Transcript

Plastic Optical Fiber (POF) Cables, Patch Cords and Plugs DATA SHEET Plastic Optical Fiber (POF) Cables, Patch Cords and Plugs FEATURES • Cost-effective, rugged optical links • Compatible with IEC 60793-2-40 Class A4a standard • Cable flameproof to UL grade VW-1 • Cable available in reels for on-site installation, or for making complex harnesses • Cable suitable for use with Firecomms POF transceivers, including RedLink®, LC and OptoLock®. • LC plugs available for easy cable termination • Patch cords in a variety of convenient standard lengths • Compatible with Versatile Link connectors and fiber optic transmitter and receivers APPLICATIONS • Control links within high voltage electrical control equipment • Data communication where extreme immunity to EMI is required • Links between equipment that requires electrical isolation to be maintained • Rugged links in hostile environments Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. DESCRIPTION Firecomms offers a range of high quality POF cables, LC plugs, and pre-assembled patch cords in both LC and RedLink® styles, suitable for use with the company’s range of transceivers and other industry-standard products. POF cable is delivered on reels for convenience when installing runs of cable into equipment or buildings, making harness assemblies, or making custom length patch cords in small quantities. Both single cable and twin (figure of eight) cable are available. Firecomms LC plugs may be assembled easily onto twin cable to prepare it for use with Firecomms LC transceivers. Firecomms patch cords are available in a convenient range of lengths for use with RedLink or Versatile Link transmitters and receivers, and LC transceivers. POF Cables, Patch Cords and Plugs DATA SHEET 2 SPECIFICATIONS Table 1 BARE CABLE SPECIFICATIONS Parameter Symbol Min Storage Temperature T stg Operating Temperature Minimum Bend Radius Max Unit -40 +85 °C T op -40 +85 °C R min 25 [1] Repeat Bending Endurance Typical mm 10,000 Numerical Aperture NA 0.5 α Attenuation at 650 nm Tensile Stress Simplex/Duplex 0.19 70/140 UL Flame Resistant Rating dB/m N VW-1 Fiber Diameter, including Cladding Dc 0.94 1 1.06 mm Cable Diameter – Simplex Dj 2.13 2.2 2.27 mm Twin Cable – Minor Axis Dj 2.13 2.2 2.27 mm Twin Cable – Major Axis Dm 4.3 4.4 4.5 mm Jacket Material Flame Resistant PE or PVC Jacket Color Black or Grey Jacket Diameter Minor Axis Major Axis Optical Fibre Jacket FIGURE 1 Duplex POF cross section. Note: 1. Repeat bending loss increment B (90° bend in direction of minor axis, 25 mm radius, deadweight 500 g). Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. POF Cables, Patch Cords and Plugs DATA SHEET 3 SPECIFICATIONS (continued) Table 2 LC PLUGS SPECIFICATIONS 8 GND Parameter Symbol Vcc Min 1 -40 2 Typical Max Unit +85 °C Storage Temperature T stg NP Operating Temperature T op GND -40 3 +85 °C Installation Temperature TI 0 TTL (D+) 4 +70 °C Retention Force, Connector to Transceiver FR 5 GND N Insertion Force, Connector to Transceiver FI Durability, Mating Cycles 100 9 500 Standards Compliance IEC 61754-20 Edition 2 Fixing Method Crimp FIGURE 2 LC POF plug. Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. IC 12 N POF Cables, Patch Cords and Plugs DATA SHEET 4 SPECIFICATIONS (continued) 33.0 [1.300] 3.8 [0.150] CRIMP RING 3.8 [0.150] 25.4 [1.000] SIMPLEX LATCHING CONNECTOR 28.2 [1.110] 3.8 [0.150] 7.1 [0.280] Ø3.8 [0.150] 5.8 [0.230] SIMPLEX FRICTION CONNECTOR 7.4 [0.290] DUPLEX CRIMP RING 4.57 [0.180] 10.2 [0.400] 10.2 [0.400] DUPLEX CRIMP RING 4.57 [0.180] 11.0 [0.434] 12.2 [0.480] 32.0 [1.260] 32.0 [1.260] 38.1 [1.500] 38.1 [1.500] DUPLEX FRICTION CONNECTOR DUPLEX LATCHING CONNECTOR FIGURE 3 RedLink plug. Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. 8.9 [0.350] Ø3.8 [0.150] 5.8 [0.230] 7.4 [0.290] 5.1 [0.200] 19.1 [0.750] Ø2.2 [0.087] CRIMP RING 8.9 [0.350] 7.6 [0.300] Ø3.8 [0.150] 28.2 [1.110] POF Cables, Patch Cords and Plugs DATA SHEET 5 SPECIFICATIONS (continued) Table 3 PATCH CORD SPECIFICATIONS Symbol Min Max Unit Storage Temperature T stg -40 Typical +85 °C Operating Temperature T op -40 +85 °C Installation Temperature TI 0 +70 °C Tensile Force, LC Connector to Cable FT 16 N Tensile Force, Simplex RedLink Connector to Cable FT 8.5 N Tensile Force, Duplex RedLink Connector to Cable FT 14 N (6.25) Parameter Duplex - w/Latch L FIGURE 4 LC POF patch cords. Simplex - No Latch Simplex - w/Latch (10.16) Duplex - No Latch Duplex - w/Latch L FIGURE 5 RedLink patch cords. Note: Simplex RedLink patch cords have a blue plug at one end and a grey plug at the other end. Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. POF Cables, Patch Cords and Plugs DATA SHEET 6 ORDERING INFORMATION Table 4 ORDERING INFORMATION Part Number Name Description Versatile Link Cross Reference FC-100-0SB 100m Reel Simplex POF Cable Reel 0.5NA SI-POF simplex N/A FC-500-0SB 500m Reel Simplex POF Cable Reel 0.5NA SI-POF simplex N/A FC-100-0DB 100m Reel Duplex POF Cable Reel 0.5NA SI-POF duplex N/A FC-500-0DB 500m Reel Duplex POF Cable Reel 0.5NA SI-POF duplex N/A FP-00C-LD0 LC Plug for POF LC plug for POF N/A FG-00C-LZ0 LC Dust Cap White dust cap to fit LC plug N/A FP-00C-VS0 RedLink Simplex Friction Plug, Grey FP-00C-US0 RedLink Simplex Friction Plug, Blue FP-00C-YS0 RedLink Simplex Latching Plug, Grey FP-00C-XS0 RedLink Simplex Latching Plug, Blue Blue latching simplex plug with crimp ring HFBR-4513Z FP-00C-RD0 RedLink Duplex Friction Plug Duplex plug with crimp ring, no latch HFBR-4506Z FP-00C-SD0 RedLink Duplex Latching Plug Duplex latching plug with crimp ring HFBR-4516Z FD-xxx-LDB LC Duplex Patch Cord FD-xxx-BSB RedLink Simplex Patch Cord, Friction Plugs FD-xxx-CSB RedLink Simplex Patch Cord, Latching Plugs FD-xxx-RDB RedLink Duplex Patch Cord, Friction Plugs FD-xxx-SDB RedLink Duplex Patch Cord, Latching Plugs Grey simplex plug with crimp ring, no latch Blue simplex plug with crimp ring, no latch Grey latching simplex plug with crimp ring XXX m LC duplex patch cable 0.5NA SIPOF XXX m RedLink simplex patch cable with friction plug 0.5NA SI-POF XXX m RedLink simplex patch cable with latch plug 0.5NA SI-POF XXX m RedLink duplex patch cable with duplex friction plug 0.5NA SI-POF XXX m RedLink duplex patch cable with duplex latch plug 0.5NA SI-POF HFBR-4501Z HFBR-4511Z HFBR-4503Z N/A N/A N/A N/A N/A The sequence-xxx in each part number should be replaced by one of the following standard lengths: Table 5 PART NUMBER LENGTH CODE Code Length 30C 30 cm patch cord 01M 1 m patch cord 02M 2 m patch cord 05M 5 m patch cord 100 100 m reel 500 500 m reel Firecomms Ltd. • 2200 Airport Business Park • Cork, Ireland • Ph +353 (21) 4547100 • Fax +353 (21) 4322657 • www.firecomms.com Copyright (c) 2013 Firecomms Ltd. Cables, Patch Cords and Plugs Revision B Firecomms assumes no responsibility for inaccuracies or omissions in the information contained in this document. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein.