Maximal3RHD Rack Mount Access Power Controller Rev. DSMaximal3RHD - 11012012
Overview Maximal3RHD rack mount access power controller distributes and switches power to access control systems and accessories. It converts a 115VAC 50/60Hz input into eight (8) independently controlled 12VDC or 24VDC PTC protected outputs. Outputs are activated by an normally open (NO) or normally Maximal3RHD closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs.
Input:
Specifications Battery Backup:
• 115VAC60Hz.,1.9amp. • Normallyclosed[NC]ornormallyopen[NO] dry contact inputs (switch selectable).
Outputs: • 12VDCor24VDC@6amptotaloutputcurrent. • Eight(8)PTCprotectedoutputs. • MaximumcurrentperACM8R-Moutputis2amp. • IndividuallyselectableMagLock/Strike(Fail-Safe, Fail-Secure) solid state fuse protected outputs. • Thermalandshortcircuitprotectionwithautoreset.
Fire Alarm Interface: • LatchingorNon-Latchingfirealarmresetswitch individually selectable for each output. • RemoteresetcapabilityforlatchingFireAlarm Interface mode. • FireAlarmdisconnectinputoptions: a)Normallyopen[NO]ornormallyclosed[NC] dry contact input. b)Polarity reversal input from FACP signaling circuit.
Visual Indicators: • IndividualOutputStatusLEDslocatedonthe front panel.
• Built-inchargerforsealedleadacidorgeltype batteries (if batteries are required install separate enclosure). • Maximumchargecurrent.7amp. • Automaticswitchovertostand-bybattery when AC fails. • Zerovoltagedropwhenunitswitchesovertobattery backup (AC failure condition).
Supervision: • ACfailsupervision(form“C”contact). • Lowbatteryandbatterypresencesupervision (form“C”contact).
Additional Features: • Removableterminalblockswithlockingscrewflange. • 3-wirelinecord. • Illuminatedmasterpowerdisconnectcircuitbreaker with manual reset.
Mechanical: • Dimensions(HxWxD)(approx.):3.25”(82.55mm)x 19.125”(485.78mm)x8.5”(215.9mm) • Shipping Weight (approximate):12.7lbs(5.76kg).
Maximal3RHD Rack Chassis Dimensions 3.25”(82.55mm)Hx19.125”(485.78mm)Wx8.5”(215.9mm)D
TOP & BOTTOM 17.625" 447.67mm
8.5" 215.9mm
FRONT
19.125" 485.76mm 0.75" 19.05mm
AltronixCorp.-14058thStreet,Brooklyn,NY11220•718-567-8181•888-258-7669•altronix.com