Transcript
AnaSem 安纳森
Analog Semiconductor IC
MRX1550H Series 5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnetic Sensor Switch (IMPORTANT: Please check the last page for Genuine Product Labeling)
Website: Tel: Email:
Rev. E13-01
www.anasemi.com +852-3590-8442
[email protected]
AnaSem .......... Future of the analog world
Rev. E13-01
Products Data Sheet
AnaSem
Analog Semiconductor IC
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series GENERAL DESCRIPTIONS MRX1550H series are monolithic ICs with built-in MR magnet resistive element and CMOS switch. It becomes the non-contact switch with low current consumption, high sensitivity and reliability which is combined with magnet. A horizontal magnetic field parallel to the electrode of the package can be detected by an arbitrary polarity. (N pole ⇔ S pole)
HALOGEN RoHS COMPLIANCE
FEATURES CMOS + MR monolithic structure Low current consumption ··············································································· 4.7µA (VIN=5.0V, Ta=25°C) High-sensitivity ··············································································· Typ. 1.5mT Operating temperature range ·························································· -40 ~ +85°C Operating voltage range ································································ 1.6V ~ 6.0V Detection pulse driving cycle ································································ Typ. 50msec with 25µsec width Magnetic direction ································································································· Both direction / CMOS inverter one output Detection magnetic field ·························································································· Horizontal direction of marked side of package (Electrode parallel both direction) SOT-23 (2.9×2.8×1.1mm) Small package ································································
APPLICATIONS Detection of opening and closing : Mobile phone, Notebook PC, Microwave oven, Washing machine, Rice cooker, Refrigerator, Electronic dictionary, Digital camera, etc. Detection of position : Air cylinder, Antitheft window, Digital door lock, etc. Detection of water level : Water purifier, Humidifier, Bidet, etc. Detection of rotation : Water meter, Gas meter, Wattmeter, Speed meter, etc. Power supply switch : Cordless phone, Electric toothbrush, etc.
AnaSem 1
www.anasemi.com
[email protected]
.......... Future of the analog world
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
PRODUCTS NUMBERING GUIDE
MRX1550H Design version
A : CMOS output
Package form
T : SOT-23 (2.9×2.8×1.1mm)
Detection pulse cycle
H : Typ. 50msec with 25µsec width
Operating voltage
50 : 1.6V ~ 6.0V
Detection sensitivity
15 : Typ. 1.5mT
PIN CONFIGURATION / MARKING SPECIFICATION (SOT-23) Pin Configuration
Vss 3
A B C
No.
Symbol
1
VIN
2
VOUT
3
VSS
Descriptions Voltage input Output
D D D D D
Power ground
2
1 Vin
Vout
Marking Specification
(Top view)
Code
Mark
Contents
A
M
Series name
BC
AA
Products specification & version
D
Internal rule
Lot number
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
BLOCK DIAGRAM
Direction of magnetic field
Switch VOUT Sampling circuit R1
R2 Latch circuit
VSS R3
R4
CMOS drive circuit T1
VIN
ABSOLUTE MAXIMUM RATINGS Items
Symbol
Min.
Typ.
Max.
Conditions
Operating temperature
TOPR
-40
-
+85
°C
Storage temperature
TSTG
-50
-
+125
°C
Supply voltage
VMAX
VIN-0.3
-
VIN+6.0
V
Assembly temp. condition
TASY
-
255
260
t=max:5sec/Tmax
Unit
°C
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
ELECTRICAL CHARACTERISTICS (Unless otherwise specified, VDD=5.0V, Ta=25°C)
Items
Symbol
Min.
Typ.
Max.
Operating voltage
VIN
1.6
5.0
6.0
Current consumption
IAVG
-
4.7
6.5
Avg. current at VIN=5.0V
ts
-
50
90
Pulse width : 1/2000
“H”-level output voltage
VOH
0.9VIN
-
-
IOUT=+1.0mA
V
“L”-level output voltage
VOL
-
-
0.1VIN
IOUT=-1.0mA
V
Detection pulse driving cycle
Conditions
Unit V µA msec
MAGNETIC CHARACTERISTICS (Unless otherwise specified, VDD=5.0V, Ta=25°C)
Items Magnetic flux density at operating point (H→L)
Magnetic flux density at release point (L→H) Width of hysteresis
Symbol
Min.
Typ.
Max.
MOPS
1.0
*
1.5
2.2
MOPN
-2.2
-1.5
-1.0
MRPS
0.8
1.2
1.9
MRPN
-1.9
*
-1.2
-0.8
MHYS
0.1
*
0.3
0.8
*
Unit mT
*
*
mT mT
Note : The values with [*] marks are guaranteed by design, not tested in production.
MAGNETIC-ELECTRIC CONVERSION CHARACTERISTIC VOUT VOH
N-pole
S-pole
VOL MHYS
MHYS Magnetic flux density
MRPN
MOPN
0
MRPS
MOPS
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
MAGNETIC FLUX DENSITY AND OUTPUT VOLTAGE LEVEL Conditions Magnet & Power Magnet = OFF Magnet = ON Magnet = OFF
/ /
Power = ON Power = ON
/
Output level
Magnet flux density
Power = ON
M = 0mT
High-level
M ≧ 2.2mT
Low-level
M ≦ 0.8mT
High-level
DETECTION PULSE DRIVING CYCLE (SAMPLING CYCLE) IDD
Period (Typ. 50mS) (VDD=5.0V) Awake (25µS)
IDD ON (Typ. 5.0mA) Sleep (Output latched)
IDD AVG (Typ. 4.7µA) IDD OFF (Typ. 2.2µA) time
OUTPUT SWITCHING TIMING CHART On Sampling pulse MHYS
Off
Magnetic flux
MOP
(Typ. 1.5mT)
MRP
(Typ. 1.2mT)
H-level VOUT L-level Latch
Latch
Latch
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
TEST CIRCUIT S or N Direction of magnetic field
VOUT
VSS
15pF (including probe capacitance)
VIN
A N or S
STANDARD MAGNET SPECIFICATIONS P-point : Magnetic flux density measuring position
0.5mm
Magnet maker : TDK Corp. / Japan Neodymium magnet Magnetic specification : NE047BW Size : 4.0 × 3.0 × 0.5mm
3.0mm 4.0mm Magnetization direction for reaction of sensor
DETECTION DISTANCE SIMULATION (with standard magnet) Vertical direction (VD)
Horizontal direction (HD) ( HD = 0mm )
( VD = 3mm )
20
10 9
Standard magnet Detection point of sensor
16
Magnetic flux density (mT)
Magnetic flux density (mT)
18 14 12 10 8 6 4 2 0
1.5mT 2
4
6
8
10
12
14
16
18
20
Standard magnet Detection point of sensor
8 7 6 5 4 3 2
1.5mT
1 0
2
Vertical distance (mm)
4
6
8
10
12
14
16
18
20
Horizontal distance (mm)
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
TYPICAL ELECTRIC CHARACTERISTICS Magnetic flux density vs. Input voltage
Magnetic flux density vs. Ambient temp.
(Ta=25°C)
(VIN=5.0V)
2 1
3 Magnetic flux density (mT)
Magnetic flux density (mT)
3 MOPS MRPS
0 -1 MRPN
-2 MOPN
-3
2
MOPS
1
MRPS
0 -1 MRPN
-2 MOPN
-3 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
3.8 4.0 4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0 Input voltage (V)
Temperature (°C)
Current consumption vs. Input voltage
Current consumption vs. Ambient temp. 7
6
6
Current consumption (µA)
Current consumption (µA)
(Ta=25°C) 7
5 4 3 2 1 0 3.8 4.0 4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0
(VIN=5.0V)
5 4 3 2 1 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Temperature (°C)
Input voltage (V)
Sampling period vs. Input voltage
Sampling period vs. Ambient temp. 90
80
80
Sampling period (msec)
Sampling period (msec)
(Ta=25°C) 90
70 60 50 40
(VIN=5.0V)
70 60 50 40
30
30
20 3.8 4.0 4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0
20 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 Temperature (°C)
Input voltage (V)
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
APPLICATION INFORMATIONS Detection of magnetic field To operate output switch, the magnetic field should be applied to the sensor with sufficient magnetic flux density and correct direction. MR series are designed to be ON-state (L-level output) when the horizontal direction magnetic field is applied in parallel to the marked side of sensor, with sufficient magnetic flux (MOPS or MOPN value) regardless of polarity of magnet. Because MR series detect the horizontal direction magnetic field, it has not influence of the reverse-magnetic field. And also, MR series detect the vertical direction magnetic field according to the level of magnetic flux, so that it is possible to apply to not only slide type but also fold type. Front view
VSS
Top view N or S
S or N 35°
Detection direction
N or S
S or N 35°
(Marked side)
VIN
VOUT
VIN
VOUT
Application example 1 -- [Fold type] VD Magnet MR sensor
VD
VD
Position B Output level = Low → High
Position A Output level = Low
Position C Output level = High
In case MR series is used for fold type cellular phone, IC sense the conditions of opening and shutting of the cover by detection of the magnetic flux according to the distance between IC and magnet. In position A, output is L-level (ON-state) because the detected magnetic flux is sufficient. The magnetic flux decrease according to the magnet is moved from IC (Position A→B). Then the IC is turned H-level (OFF-state) because the magnetic flux become MRP or less (Position B→C). Moving direction
Moving direction
S or N
Magnetic field direction N or S
S or N
Moving direction
Magnetic field direction N or S
Moving direction Detection direction
Detection direction
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
Application example 2 -- [Slide type & Rotary type] Magnet
VD
MR sensor
HD
HD
Position A
Position B
Position C
Output level = Low
Output level = Low → High
Output level = High
Magnet MR sensor
MR sensor
Position A Output level = High → Low
MR sensor
Position B Output level = Low
MR sensor
Position C Output level = Low → High
Position D Output level = High
In the detection of the slide type, there are two ways of arrangement of magnetic field detecting direction against moving direction. One is parallel and another is cross with moving direction. In case of parallel positioning of magnetic field with moving direction [arrangement 1], the output of IC might be L-level (ON-state) → H-level (OFF-state) → L-level (ON-state) → H-level (OFF-state) due to reverse-magnetic field. To prevent from this malfunction, it is recommended to arrange the detection direction of sensor and magnetic field to be crossed with moving direction of cover [arrangement 2].
S or N
Moving direction
Moving direction
N or S
Moving direction
S or N
Moving direction Magnetic field direction
Magnetic field direction
N or S Detection direction
Detection direction
[Arrangement 1]
[Arrangement 2]
Parallel the direction of detection magnetic field with the moving direction
Cross the direction of detection magnetic field with the moving direction
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
PACKAGE DIMENSIONS (SOT-23)
(Unit : mm) 0.65 –0.15
+0.10
2.9±0.2
1.1~1.3
0~0.35
0.45
1.6±0.15
2.8±0.2
+0.10 0.4 –0.15
(Marked Side)
0~0.1 3~7°
+0.10
+0.10
0.16 –0.15
+0.10
0.95
+0.10
0.4 –0.15
0.65 –0.15
0.4 –0.15
0.95
1.9±0.2
2.9±0.2
1.1~1.3
Recommended land pattern
1.0
2.4
0~0.1
+0.10
0.4 –0.15
0.8
1.0
0.8
1.0
0.8
0.95
0.95 1.9
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
TAPING AND LOADING SPECIFICATIONS (SOT-23) (Unit : mm)
1.65 max.
Mark
ø1.05±0.05
3.5±0.05
3.3±0.1
Mark
2.0±0.05
4.0±0.1
8.0±0.2
ø1.5 +0.1 –0
0.2±0.05
1.75±0.1
4.0±0.1
3.35±0.1
Taping direction
REEL DIMENSIONS (SOT-23) (Unit : mm)
120°
ø60±1
2.0±0.5
(3,000 pcs / reel)
ø178±2
ø13±0.5
90°
9.0±0.5
AnaSem www.anasemi.com
[email protected]
AnaSem
AnaSem may change the products described in this data sheet, or may discontinue production or services without any notice in order to supply the best products through improve the design and performance. Customers are recommended to obtain the latest data or information before placing orders in order to make sure the data or information required is the newest. It is necessary for customers to fully understand the products described in this data sheet and to use it in accordance with its specifications. The products described in this data sheet are not intended to use for the apparatus which have influence on human lives due to the failure or malfunction of the products. AnaSem Corp. is not responsible for any support to customer’s application, product design, software performance, patent infringement or service. AnaSem Corp. does not disclose or imply a guarantee or description about being licensed based on patents, copy-rights, circuit location license, or other intellectual properties associated with the devices or combinations in which the products or service of AnaSem Corp. are used or can be used, or which cover the methods. Customers should not export, directly or indirectly, any products without obtaining required licenses and approvals in advance from appropriate government agencies.
AnaSem www.anasemi.com
[email protected]
5.0V Input voltage, 1.5mT High sensitivity CMOS MR Magnet Sensor Switch
MRX1550H Series
Rev. E13-01
GENUINE PRODUCT LEGITIMATE LABEL DEFINITION
Green colored Circle “RoHS” Label
Other specific customized Labels
Ordinary Product Information Bar Code
Our internal Outgoing Check Code 3 Our Internal QR Check Code 2
AnaSem Logo and Brand Name (Black color Logo)
Our Internal Product Check Code 1 Genuine labels MUST include our correct contact information as shown
AnaSem www.anasemi.com
[email protected]