Transcript
Product Data Sheet
PDU-6A
Power Distribution Unit, indoor, 6 channels, automatic current sensing
Product Description The PDU-6A power distribution unit (PDU) from RFS can be used with single or dual Tower Mounted Amplifiers (TMAs). It powers up to six TMAs through the bias-T. Its intelligent self-learning current ability allows multiple TMAs with different current draws to be automatically powered, without complex adjustments at the site. Upon a manual reset of the front panel switch the PDU measures the current flow in each of the DC output channels. Once a DC output channel is enabled the normal operating current is saved and if a significant change in operating current (±30mA) is detected on any channel of the PDU an alarm state is raised. The PDU displays individual TMA monitoring status via 6 LEDs located on the front panel (1 per channel). The PDU-6A is extremely compact and lightweight, and allows for easy installation in a standard 19” rack. Additionally, its superior design ensures maximum reliability in the most extreme environmental conditions. The following cables are included with the units: Power supply cable, alarm cable,and grounding cable. A DC-injection cable can be purchased separately.
Features/Benefits • Self-learning current ability that works with a wide variety of TMAs – Eliminates complex site adjustments • 22-50 volt DC input range that is compatible to most BTS’s – Provides flexibility for overall system design • 19 inch rack mount design – Facilitates easy installation • Summary relay alarm output – Adds additional monitoring • LED status indicators for each individual TMA – Ensures system reliability
Technical Specifications Power Distribution Unit 22-50 (any polarity) Power Distribution Unit, indoor, 6 channels, automatic current sensing 19” rack, wall mount 10.8 min, 12.8 max, 12V nominal 900 (channel 1-3 combined), 900 (channels 4-6 combined) 16 Learned value at time of reset 480 to 500 per channel Learned value at time of reset (+/- 30 mA) -20 to +60 (-4 to +140) ETSI 300-019-2-3 Class 3.2E 1 (2.2) 440 x 483 x 92 (17.3 x 19.0 x 3.6)
Product Type Power Supply Voltage, VDC Configuration Mounting Channel Output Voltage, VDC Output Current, Max, mA Power Consumption, Max, W Nominal Current, mA Valid Learned Current, mA Current Mode Window, mA Temperature Range, °C (°F) Environmental Weight, kg (lb) Dimensions, H x W x D, mm (in)
All information contained in the present datasheet is subject to confirmation at time of ordering
Notes Package includes the following cables: - Power Cable, 6 meters, Molex to open tail - Alarm Cable, D25 to open tail wired for summary alarm - Grounding Cable, 1 meter
Other Documentation PDU-6A User Manual: PDU-6_User Manual_5_30_2014_rev03.pdf
RFS The Clear Choice ® Please visit us on the internet at http://www.rfsworld.com/
PDU-6A
Rev: E / 5/30/2014
Print Date: 31.03.2017 Radio Frequency Systems
Product Data Sheet
PDU-6A
Power Distribution Unit, indoor, 6 channels, automatic current sensing
All information contained in the present datasheet is subject to confirmation at time of ordering
PDU TMA Compatibility Guide
RFS The Clear Choice ® Please visit us on the internet at http://www.rfsworld.com/
PDU-6A
Rev: E / 5/30/2014
Print Date: 31.03.2017 Radio Frequency Systems