1 Form A 5A slim power relay for interface
RoHS compliant Protective construction: Sealed type
FEATURES 1. Slim size (width 5 mm .197 inch, height 12.5 mm .492 inch) permits higher density mounting Despite the slim 5 mm .197 inch width, the 20 mm .787 inch length is still compact and the 12.5 mm profile is low. Even when a socket is used, the height is still only 18 mm .709 inch. Suitable for high-density mounting, these relays enable device size smaller.
2. Nominal operating power: High sensitivity of 120mW Enables smaller power supplies, facilitates energy saving applications, and contributes to device size smaller. 3. Control from low level loads to 5 A Use of gold-clad twin contacts enables control of low level loads down to 100 mV 100 µA and up to 5 A 250 V AC and 30 V DC. 4. Reinforced according to IEC1131-2 (TÜV) 5. High surge breakdown voltage (4000 V) and high breakdown voltage (2000 V) Between contacts and coil of 2,000 V and surge resistance of 4,000 V work to prevent controller malfunctions caused by noise and surges. 6. Outstanding vibration and shock resistance Functional shock resistance: 147 m/s2 Functional vibration resistance: 10 to 55 Hz (at double amplitude of 2.5 mm .098 inch) Keeps equipment from miss-operation due to vibration and shock. Can be used as mounted on control panel doors.
PA RELAYS 7. Sealed construction allows automatic washing 8. SIL (single in line) terminal layout 9. Complies with safety standards Complies with Japanese Electrical Appliance and Material Safety Law, and certified by UL, CSA, and TÜV. 10. Sockets are available
TYPICAL APPLICATIONS 1. Industrial equipment, office equipment 2. Measuring devices and test equipment 3. Interface relays for programmable controllers 4. Output relays in small devices such as timers, counters, sensors, and temperature controllers
ORDERING INFORMATION PA 1a Contact arrangement 1a: 1 Form A (Bifurcated) Nominal coil voltage (DC) 5, 6, 9, 12, 18, 24V Note: Certified by UL, CSA and TÜV
TYPES Contact arrangement
1 Form A
Nominal coil voltage 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC
Part No. PA1a-5V PA1a-6V PA1a-9V PA1a-12V PA1a-18V PA1a-24V
Standard packing: Tube: 25 pcs.; Case: 1,000 pcs.
* Terminal sockets available.
2014.02
industrial.panasonic.com/ac/e/
–1–
© Panasonic Corporation 2014
ASCTB204E 201402-T
PA RATING 1. Coil data
5V DC
Nominal operating current [±10%] (at 20°C 68°F) 24mA
6V DC 9V DC 12V DC 18V DC 24V DC
20mA 13.3mA 10mA 6.7mA 7.5mA
Nominal coil voltage
Pick-up voltage (at 20°C 68°F)
70%V or less of nominal voltage *1 (Initial)
Drop-out voltage (at 20°C 68°F)
5%V or more of nominal voltage*1 (Initial)
Coil resistance [±10%] (at 20°C 68°F)
Nominal operating power
Max. applied voltage (at 20°C 68°F)
120mW
120%V of nominal voltage
208Ω 300Ω 675Ω 1,200Ω 2,700Ω 3,200Ω
180mW*2
Notes: *1 Pulse drive (JIS C 5442) *2 24V DC, 120mW type are also available, please consult us.
2. Specifications Characteristics Contact
Rating
Electrical characteristics
Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Insulation resistance (Initial) Breakdown voltage (Initial)
Between open contacts Between contact and coil
1,000 Vrms for 1min. (Detection current: 10mA.) 2,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown voltage (Initial)
Between contacts and coil*2
4,000 V
Temperature rise (coil) (at 20°C 68°F) Operate time (at nominal voltage) (at 20°C 68°F) Release time (at nominal voltage) (at 20°C 68°F) Functional Destructive Functional Vibration resistance Destructive Mechanical
Shock resistance Mechanical characteristics
Expected life
Conditions
Specifications 1 Form A (Bifurcated) Max. 30 mΩ (By voltage drop 6 V DC 1A) Au-clad AgNi type 5 A 250 V AC, 5 A 30 V DC 1,250 VA, 150 W 250 V (AC), 110 V (DC) 5A 120 mW (5 to 18 V DC), 180 mW (24 V DC) 100µA 100mV DC Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Electrical Conditions for operation, transport and storage*3 Max. operating speed
Unit weight
Max. 45°C (By resistive method, nominal coil voltage applied to the coil, nominal switching capacity.) Max. 10 ms Max. 5 ms Min. 147 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.) Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) 10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 3.5 mm Min. 2×107 (at 180 times/min.) Min. 105 (3 A 250 V AC, 30 V DC, resistive load) Min. 5×104 (5 A 250 V AC, 30 V DC, resistive load) (at 20 times/min.) Ambient temperature: –40°C to 70°C –40°F to 158°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at nominal switching capacity) Approx. 3 g .15 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES.
REFERENCE DATA 1. Max. switching capacity
2. Life curve
3.-(1) Coil temperature rise (180 mW) Tested sample: PA1a-24V Measured portion: Inside the coil Ambient temperature: 20°C 68°F
1
DC resistive load
90 Temperature rise, °C
AC resistive load 5 4 3 2
No. of operations, ×104
Contact current, A
100
100 50 30 20 10
AC 125 V resistive load DC 30 V resistive load AC 250 V resistive load
0.5 0.4 0.3 0.2
80 70 60 50 5A 3A 2A 0A
40 30 20 10
20 30 50 100 200 300 Contact voltage, V
0.5
1
2 3 5 10 Switching capacity, A
Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/
–2–
100
0
100
110 120 130 140 150 Coil applied voltage, %V
© Panasonic Corporation 2014
ASCTB204E 201402-T
PA 3.-(2) Coil temperature rise (120 mW)
4.-(1) Operate & release time (120 mW)
4.-(2) Operate & release time (180 mW)
Tested sample: PA1a-12V Measured portion: Inside the coil Ambient temperature: 20°C 68°F
Tested sample: PA1a-12V, 20 pcs.
Tested sample: PA1a-24V, 20 pcs.
9
80 70 60 50 40
5A 3A 2A 0A
30 20
7 6
Operate time
5 Max. x Min.
4 3
Release time
Max. x Min.
2
10 0
8
1 100
0
110 120 130 140 150 Coil applied voltage, %V
80
6. Malfunctional shock
Tested sample: PA1a-12V, 6 pcs.
Tested sample: PA1a-12V, 6 pcs.
Rate of change, %
40 30 20
X Pick-up voltage
Z
Z’Y’ Y
7 6 Operate time
5 4 3
Max. x Min. Max. x Min.
Release time
2 1 80
90 100 110 120 Coil applied voltage, %V
Deenergized condition Energized condition
Y 980m/s2
X’ X 980m/s2
10
8
0
90 100 110 120 Coil applied voltage, %V
5. Ambient temperature characteristics
Operate & release time, ms
10
9
Operate & release time, ms
10
90 Temperature rise, °C
100
Z 980m/s2
Drop-out voltage –40
–20
50
20
0 –10 –20
75
Ambient temperature, °C
980m/s2 Z’
980m/s2 X’
–30
980m/s2 Y’
–40
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Relay External dimensions
CAD Data
0.5 .020
1.3 .051 8.8 .346
PC board pattern (Bottom view)
1.2 .047 12.5 2.9 (12.8 max.) .114 .492 (.504 max.)
6 4.8 .237 .189
2.54 .100
3.5 .138 5 .197
2.54 .100
1.2 dia. .047 dia. 1.2 dia. .047 dia.
1.0 dia. .039 dia. 1.0 dia. .039dia.
0.5 .020 10.16 .400 20 .787
5.08 .200
0.8 .031 1.11 .044
0.25 .010 1.18 .046
10.16 .400
5.08 .200
Tolerance: ±0.1 ±.004
Schematic (Bottom view) 1 2
General tolerance: ±0.3 ±.012
5
6
N.O. COM Coil
SAFETY STANDARDS UL/C-UL (Recognized) File No. Contact rating E43149 5A 250V AC (5×104) 5A 30V DC (5×104) 3A 250V AC (105) 3A 30V DC (105)
File No. LR26550 etc.
CSA (Certified) Contact rating 5A 250V AC (5×104) 5A 30V DC (5×104) 3A 250V AC (105) 3A 30V DC (105)
File No. B 12 01 13461 316
Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/
–3–
TÜV (Certified) Rating IEC1131-2 Reinforced
Remarks TÜV rating 5A 250V AC (cosφ =1.0) (5×104) 5A 30V DC (0ms) (5×104) 3A 250V AC (cosφ =1.0) (105) 3A 30V DC (0ms) (105)
© Panasonic Corporation 2014
ASCTB204E 201402-T
PA NOTES 4. When mounting the relays within 1 mm .039 inch, please notice the condition below. 1) Mount the relays in the same direction.
4) About the electrical life for close mounting, please refer to data below. 3.0 2.0
Within 1 mm .039 inch
Contact current, A
1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES” on page B-1. 2. If it includes ripple, the ripple factor should be less than 5%. 3. Specification values for pick-up and drop-out voltages are for the relay mounting with its terminals below. 100 90
AC resistive load DC resistive load
1.0
0.5 0.4 0.3
80
60
Max. – x Min.
50 40
0.2
2) Coil terminals (Terminal No. 1 & 2) polarity should be arranged in the same direction.
20
30
50 100 Contact voltage, V
200 300
30 20
Drop-out voltage
10
Max. – x Min.
0 Mounting direction
–. +.
–. +.
–. +.
–. +.
–. +.
+. –.
+. –.
+. –.
+. –.
3) Allowable contact current is 2 A.
+. –.
No. of operations, ×104
Voltage, %V
70
Pick-up voltage
100
50 40 30 20
AC 125V resistive load DC 30 V resistive load AC 250 V resistive load
10
0.5
Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/
–4–
© Panasonic Corporation 2014
1.0 2.0 3.0 Switching capacity, A
ASCTB204E 201402-T
Automation Controls Catalog
PA RELAYS TERMINAL SOCKETS
ACCESSORIES
TYPES Product name Standard type terminal socket Self clinching type terminal socket
Standard type terminal socket
Self clinching type terminal socket
DIMENSIONS (mm inch)
The CAD data of the products with a
Standard type terminal socket External dimensions CAD Data 1
2
3
4
5
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Self clinching type terminal socket External dimensions CAD Data
5+0.2 –0.6 .197+.008 –.024
6
1
22.6±0.6 .890±.024
4 .157
Part No. PA1a-PS PA1a-PS-H
0.5 .020 2.54 .100 6.35 .250
2
3
4
5
5+0.2 –0.6 .197+.008 –.024
6
22.6±0.6 .890±.024
0.8 .031
3.81 .150
9±0.6 .354±.024
9±0.6 .354±.024
5.3±0.6 .209±.024
5.3±0.6 .209±.024
(0.3) (.012) 5.08 .200
3.9 1±0.25 .154 .039±.010 1.23 .048
0.25 .010 1.23 .048
0.8 .031
0.5 .020 2.54 .100 6.35 .250
3.81 .150
(0.3) (.012) 5.08 .200
General tolerance: ±0.3 ±.012
General tolerance: ±0.3 ±.012
PC board pattern (Bottom view)
PC board pattern (Bottom view)
1.0 dia. .039 dia. 1.0 dia. .039 dia.
2.54 .100
10.16 .400
1.2 dia. .047 dia. 1.2 dia. .047 dia.
1.3±0.15 .051±.006
0.8±0.25 dia. 1.2±0.05 dia. .031±.010 dia. .047±.002 dia. 0.8±0.25 dia. 1.2±0.05 dia. .031±.010 dia. .047±.002 dia.
5.08 .200
2.54 .100
Tolerance: ±0.1 ±.004
10.16 .400
5.08 .200
Tolerance: ±0.1 ±.004
INSTALLING AND REMOVING Installing and removing the relay 1) Firmly insert the relay into the socket with the terminals going in the direction of the blade receptacles. (1) Insert the removal key into the socket slots.
2014.02
2) The relay can be easily removed using the removal key (APA801). (2) Pull the removal key up to remove the relay.
industrial.panasonic.com/ac/e/
–1–
(3) Slide the removal key off of the relay.
© Panasonic Corporation 2014
ASCTB263E 201402-T
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic: PA1A-12V PA1A-24V PA1A-5V PA1A-PS PA1a-18V PA1a-6V PA1a-9V PA1A-12V-Y1 PA1A-5V-Y1 PA1A-PSH