Preview only show first 10 pages with watermark. For full document please download

Datasheet Pbag-12v002,2-t1a

   EMBED


Share

Transcript

CJ12-2.2 (12V2.2AH) Specification Nomial Voltage 12V Nomial Capacity(20HR) 2.2AH Dimension Length Width Container Height Total Height (with Terminal) 178 1mm (7.00 inches) 35 1mm (1.38 inches) 60 1mm (2.36 inches) 66 1mm (2.60 inches) Approx 1.0 kg (2.21lbs) Approx Weight Terminal T1 Container Material ABS Rated Capacity 2.20 AH/0.115A 2.14AH/0.214A 1.95 AH/0.39A 1.7 7 AH/0.59A 1.44 AH/1.44A (20hr ,1.80V/cell,25 0C/77 0F) (10hr,1.80V/cell,250C/77 0F) (5hr,1.75V/cell,25 0C/77 0F) (3hr,1.75V/cell,25 0C/77 0F) (1hr,1.60V/cell,25 0C/77 0F) Applications All purpose Uninterruptable Power Supply (UPS) Electric Power System (EPS) Max. Discharge Current 34.5A (5s) Internal Resistance Approx 90mΩ Emergency backup power supply 0 Emergency light 0 Operating Temp.Range Discharge : -15 50 C (5 120 F) Charge : 0 40 0C (5 104 0F ) Storage : -15 40 0C (5 104 0F) Nominal Operating Temp. Range 25 Railway signal Aircraft signal 3 0C (77 5 0F ) Alarm and security system Initial Charging Current less than0.69A.Voltage Cycle Use Electronic apparatus and equipment 14.4V~15.0V at 25 0C (77 0F)Temp. Coefficient -30mV/ 0C Communication power supply No limit on Initial Charging Current Voltage Standby Use DC power supply 13.5V~13.8V at 25 0C (77 0F)Temp. Coefficient -20mV/ 0C Auto control system 103% 40 C (104 F) o o 25 C ( 77 F) 100% o o 0 C ( 32 F) 86% series batterys may be stored for up to 6 months at 25 0C (770 F) and then a freshening charge is required. For higher temperatures the time interval will be shorter. o Capacity affected by Temperature Self Discharge o VdS 9 Germany t est ed Constant Current Discharge (Amperes) at 25 C (77 F ) 0 0 F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 4.38 3.36 2.79 2.41 1.86 1.37 1.16 0.68 0.54 0.44 0.355 0.308 0.248 0.207 0.114 1.80V/cell 5.88 4.30 3.37 2.85 2.20 1.60 1.30 0.75 0.58 0.46 0.381 0.330 0.263 0.214 0.115 1.75V/cell 6.63 4.72 3.68 3.06 2.28 1.66 1.36 0.77 0.59 0.47 0.391 0.339 0.268 0.220 0.116 1.70V/cell 7.30 5.15 3.93 3.22 2.37 1.72 1.40 0.79 0.60 0.49 0.401 0.346 0.272 0.224 0.118 1.65V/cell 8.05 5.55 4.17 3.42 2.51 1.77 1.43 0.81 0.63 0.50 0.412 0.354 0.276 0.229 0.120 1.60V/cell 8.88 6.03 4.46 3.64 2.65 1.84 1.44 0.84 0.65 0.52 0.426 0.362 0.279 0.231 0.121 6h 8h 10h 20h Constant Power Discharge (Watts) at 25 C (77 F ) 0 F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 0 5h 1.85V/cell 8.01 6.21 5.20 4.54 3.55 2.64 2.23 1.33 1.04 0.85 0.696 0.605 0.490 0.411 0.226 1.80V/cell 10.6 7.85 6.20 5.29 4.12 3.04 2.49 1.44 1.12 0.90 0.743 0.647 0.518 0.423 0.227 1.75V/cell 11.7 8.48 6.69 5.64 4.25 3.13 2.59 1.49 1.13 0.92 0.760 0.662 0.526 0.433 0.229 1.70V/cell 12.6 9.04 7.04 5.88 4.40 3.24 2.66 1.52 1.16 0.94 0.778 0.675 0.533 0.442 0.233 1.65V/cell 13.7 9.66 7.43 6.20 4.60 3.29 2.70 1.53 1.21 0.97 0.797 0.688 0.540 0.450 0.236 1.60V/cell 14.7 10.25 7.81 6.53 4.82 3.41 2.72 1.59 1.24 1.00 0.820 0.700 0.544 0.454 0.237 1 Dimensions T1 Terminal 3.2(0.126) 10.5 60 1 66 1 4.75(0.187) 35 1 Unit: mm [inches] 178 1 6.35(0.25) 0.8(0.031) Discharge Characteristics Float Charging Characteristics 12V 6V 4V 2V Battery Battery Battery Battery V V V V 13.0 6.5 4.33 Charge Charging Charging Volume Current Voltage Temperature:25 0 C(77 0 F) 2.16 % Terminal Voltage(V) 12.0 11.0 6.0 5.5 4.00 3.66 2.00 5.0 3.33 1.68 9.0 4.5 3.00 1.52 0.4C 1C 100 0.093C 0.05C 0.207C 90 80 15.0 7.5 14.0 7.0 2.67 1.36 30 3C 1 2 4 2C 6 8 10 40 20 60 2 4 6 8 10 20 10 0 20 H Min 2.50 Charged Volume 2.33 Charge Voltage (Constant 2.25v/cell) 0.15 13.0 0.10 2.17 6.5 After 50% Discharge 12.0 6.0 11.0 5.5 2.00 40 4.0 (V) 0.20 70 60 0.628C 50 8.0 temperature25 C 0.25 120 110 1.84 10.0 (XCA) Charging Voltage 0 0.10CA-2.25V/cell (V) (V) After 100% Discharge 0.05 1.83 Charging Current 0 0 4 8 16 12 20 32 28 24 36 40 Discharge Time Charging Time(hours) Temperature Effects in Relation to Batter Capacity Effect of Temperature on Long Term Float Life 10 120 8 Life expectancy(year) Capacity % 80 0 .2 C A 60 1 .0 C A 40 2 .0 C 20 0 -20 6 5 4 A 0 .0 5 C A 0 .1 C 100 A 3. 0C A Charging voltage : 2.25V/cell 3 2 1 0.5 -10 20 10 0 30 40 50 20 68 30 86 0 Temperature( C) Remaining Capacity(%) Capcity(%) 80 60 50% DOD 400 600 800 1000 A 250C B 60 300C 400C 40 C 20 0 30% DOD 2 4 6 8 10 12 Storage Time(Months) Ambient Termperature: 25oC (77oF) 200 100C 80 100 0 0 C F O 100 120 20 0 Self Discharge Characteristics Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. 100% DOD 50 122 Battery temperature Cycle Life in Relation to Depth of Discharge 40 40 104 A No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use.Optional charging way as below: 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell. 3.Charged for 8~10hours at limted current 0.05CA . C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles 2