Transcript
Remote Control Unit
MFR-RU Series
Remote Control Unit
MFR-RU Series
MFR-RU series Product Line-up Functions
High-end Model with LCD Display
MFR-16RUTA
MFR-39RUA MFR-18RUA
Standard Model
MFR-40RU
MFR-16RUD MFR-16RU
Simple Model
MFR-16RUW
16
18
32
MFR-64RUW
MFR-32RUW
39
40
64
Buttons
Main Unit Line-up MFR-3232/3232RPS/3216/3216RPS/1616/1616R
MFR-5000
MFR-1616
MFR-3232
Multi-format routing switchers that support 3G-SDI, HD-SDI, SD-SDI and ASI signals. FOR-A features six models, each with a different number of inputs and outputs. MFR-1616A
A multi-format routing switcher supporting 3G/HD/SD-SDI, ASI, AES, and RS-422. Inside the 8 U case a matrix of up to 128 inputs/128 outputs can be configured.
AES audio dedicated model, 16 inputs/16 outputs. MFR-3000
MFR-8000
A multi-format rouing switcher supporting 3G/HD/SD-SDI, ASI, AES, and RS-422. Offers an expanded matrix of 256 inputs/ 256 outputs in a 16 U frame. A multi-format routing switcher that builds on the solid performance of our larger MFR-5000/8000 units through redundancy and easy maintenance. Optional front panel is available.
Product Details Simple Model MFR-16RUW
MFR-32RUW
MFR-64RUW
■ 1 U compact size ■ 16 buttons (Single color: G) ■ Any function can be assigned to the 16 buttons ■ 2 dedicated function buttons ■ 1 U compact size ■ 32 buttons (Single color: G) ■ Any function can be assigned to the 32 buttons ■ 2 dedicated function buttons ■ 2 U size ■ 64 buttons (Single color: G) ■ Any function can be assigned to the 64 buttons ■ 4 dedicated function buttons
Standard Model MFR-16RU
■ 1 U compact size ■ 16 buttons (Single color: G) ■ Any function can be assigned to the 16 buttons ■ 2 function buttons (lock/page)
MFR-16RUD
■ 1 U compact size ■ 16 buttons (Single color: G) ■ Any function can be assigned to the 16 buttons ■ Equipped with a status and setting menu display ■ 2 function buttons (lock/page)
MFR-40RU
■ 1 U compact size ■ 40 buttons (3 colors: R, G, Or) ■ Any function can be assigned to any button ■ Redundant power supply (AC adapter)
High-end Model with LCD Display MFR-18RUA
■ 1 U compact size ■ 18 buttons (3 colors: R, G, B) ■ Equipped with OLED display that can show source name and assigned functions for each button (7 colors: R, G, Ye, B, W, Cy, Mg) ■ Any function can be assigned to any button ■ Redundant power supply (AC adapter)
MFR-39RUA
■ 2 U size ■ 39 buttons: 13 button x 3-row. Buttons with OLED display that can show source names or assigned functions (7 colors: R, G, Ye, B, W, Cy, Mg) ■ Apart from the main buttons, there are 6 function buttons that can be freely assigned (3 colors: R, G, Or) ■ Equipped with display showing information of current sources, destinations, and pages ■ Ideal as a main control unit covering the entire crosspoint set-up ■ Redundant power supply (AC adapter)
MFR-16RUTA
■ 2U half tabletop size ■ 16 buttons (3 colors: R, G, Or) ■ Equipped with LCD display that can show source name and assigned functions for each button (7 colors: R, G, Ye, B, W, Cy, Mg) ■ Any function can be assigned to the 16 buttons
Interface Expansion Unit The interface expansion unit lineup includes three types to suit your specific application. The number of units that can be connected is a maximum of 128, including the remote control units.
MFR-RULINK: Remote Control Relay Unit
Connects MFR main unit and MFR-RU series. It allows MFR-RU series to switch cross points and control Lock function. It also supports change settings of MFR-RU series via built-in Web server. Max. 15 MFR-RU units can be connected via LAN.
MFR-TALM: Tally Manager
MFR-TALM is a device for performing central management of tally and material names of the MFR main unit and peripheral devices (such as video switchers and multi viewers). In the tally linking system, MFR-TALM performs the tally calculation, which were originally performed by the MFR main unit, so that the tally linking can be speeded up.
MFR-GPI: GPI Unit
Provides an interface for GPI control. This 1 RU sized unit is equipped with user-assignable GPI/O (128 channels) and 4 serial ports (9-pin D-sub male). It can be used for setting Input/Output and supports system configuration.
Select Your System and Usage Information displays MFR-18RUA
MFR-39RUA
Up to 18 buttons MFR-16RUTA
Up to 2 pages
MFR-16RUD
32+ buttons
MFR-39RUA
MFR-16RUW
MFR-32RUW
MFR-40RU
MFR-64RUW
32 buttons
MFR-39RUA
MFR-40RU
Redundant power supply unit MFR-18RUA
MFR-39RUA
MFR-40RU
Simple/cost-effective model
Multi-colored buttons
MFR-16RUTA
40 buttons
MFR-64RUW
MFR-39RUA
MFR-39RUA
MFR-32RUW
39 buttons
64 buttons
Parameter settings
MFR-18RUA
MFR-16RUD
MFR-18RUA
Up to 32 pages (w/o information displays)
MFR-16RUD
MFR-16RU
18 buttons
Up to 32 pages
MFR-18RUA
MFR-16RUW MFR-16RUTA
Page up/down functions MFR-16RU
16 buttons
MFR-40RU
MFR-16RUW
MFR-32RUW
All-purpose model MFR-39RUA
MFR-64RUW
MFR-RU Series External Dimensions and Rear Panel 2.3 REMOTE CONTROL UNIT
MFR-16RUW
MFR-16RU
LOCK
POWER
REMOTE CONTROL UNIT
SETUP
RESET
430
BUSY
SETUP
LOCK
RESET
32 44
BUSY
LOCK
32 44
POWER
PAGE
430
27
▲ MFR-16RUW External Dimensions
▲ MFR-16RU External Dimensions REMOTE CONTROL UNIT
MFR-32RUW
LOCK
ENTER
PAGE
CANCEL
MFR-16RUD
REMOTE CONTROL UNIT
SETUP
RESET
32 44
BUSY
LOCK
480
BUSY
SETUP
LOCK
RESET
27
32 44
POWER
POWER
480
▲ MFR-32RUW External Dimensions
34
▲ MFR-16RUD External Dimensions
MFR-LAN
MFR-LAN
DC12V IN
RATING LABEL
RATING LABEL
DC12V IN
429
▲ MFR-16RU/16RUD Rear Panel
▲ MFR-16RUW/32RUW Rear Panel
2.3 REMOTE CONTROL UNIT
MFR-64RUW
REMOTE CONTROL UNI T
POWER
MFR-40RU
BUSY
SETUP
LOCK
RESET
76 88
BUSY
LOCK
32 44
POWER
SETUP
430
RESET
▲ MFR-40RU External Dimensions 480
27
MFR-18RUA
REMOTE CONTROL UNIT
BUSY
SETUP
LOCK
RESET
32 44
POWER
▲ MFR-64RUW External Dimensions
430
42
▲ MFR-18RUA External Dimensions MFR-LAN
MFR-LAN
2
1
SERVICE
RATING LABEL
DC12V IN
RATING LABE L
DC12V IN
429
▲ MFR-40RU/18RUA Rear Panel
▲ MFR-64RUW Rear Panel
2.3 REMOTE COMTROL UNIT
MFR-39RUA
DEST
POWER
REMOTE CONTROL UNIT
MFR-16RUTA
SRC
POWER BUSY
PAGE A
LOCK
BUSY
PAGE A
RESET
88
76 88
SETUP
LOCK SETUP
B
68 88
LOCK
RESET PAGE B
C D
430
215
42
480
▲ MFR-16RUTA External Dimensions
▲ MFR-39RUA External Dimensions MFR-LAN
2
SERVICE
RATING LABEL
1
DC12V IN
MFR-LAN DC12V IN
▲ MFR-39RUA Rear Panel
▲ MFR-16RUTA Rear Panel
MFR-RULINK
MFR-TALM
REMOTE CONTROL RELAY UNIT
105.3
28
21.2
1
2
TALLT MANAGER UNIT
21.2
SERIAL POWER
28
GPI
1
SERIAL 2 3
4
MFR-GPI
RESET
430
28 9 110
462 480
▲ MFR-GPI External Dimensions
SERVICE
1
2
SERIAL
3
4
R AT I N G L AB E L
M FR-LAN
G PI 1
▲ MFR-GPI Rear Panel
1
MFR-LAN
▲ MFR-TALM Rear Panel
32 44
GPI
GPI 2
GPI 3
GPI 4
21.2
REF IN
GPI
212
2
2 - DC12V I N - 1
REF IN
1
2
169.6
3
4
1
PC-LAN
SER. NO.
GPI UNIT
BUSY
28
2
▲ MFR-RULINK Rear Panel
POWER
105
BUSY
▲ MFR-TALM External Dimensions
SERIAL
DC12V IN
44
RESET
44
4
4
3
REF IN
MFR-LAN
3
212
1
PC-LAN
RS-422
2
169.6
▲ MFR-RULINK External Dimensions
RS-422
1
GPI SER. No.
DC12V IN
2
3
4
RESET
21.2
3.6
27.94
GPI
3.6
POWER BUSY REF IN
Specifications Simple Model
Standard Model MFR-32RUW
MFR-64RUW
MFR-16RU
Highend model with LCD display
Model Name
MFR-16RUW
MFR-16RUD
MFR-40RU
MFR-18RUA
MFR-39RUA
Buttons/Colors
16 buttons 32 buttons 64 buttons 16 buttons 16 buttons 40 buttons (1 color only: green) (1 color only: green) (1 color only: green) (1 color only: green) (1 color only: green) (3-color: red/green/ user assignable user assignable user assignable user assignable user assignable orange) 2 function buttons 2 function buttons 4 function buttons 2 function buttons 2 function buttons user assignable
18 buttons (3-color: red/green/ orange) user assignable
39 buttons (OLED buttons, 7-color) user assignable
user assignable
user assignable
user assignable
(Lock/Page)
(Lock/Page)
Name display
None
None
None
None
None
None
Available (Displayed above each button) OLED display x18 (Max. 7 characters x2 lines)
6 buttons(3-color: red/green/orange) user assignable Available (Displayed in each button) OLED display x39 (Max. 7 characters x2 lines)
Rotary selector
None
None
None
None
None
None
Available
Available
Number of Connections
Max. 128 units (including MU, remote control and GPI units)
Interfaces MFR-LAN
10/100 Base-TX RJ-45 x1 (for connection to MU; network hub required for connecting to multiple MUs)
Service
None
None
None
None
None
RS-232C 9-pin D-sub (male) x1 (for maintenance)
Temperature / Humidity 0 °C to 40 °C / 30 % to 85 % (no condensation) Power
+12 VDC Pin-connector x1
+12 VDC Pin-connector x2 (redundant power supply as standard)
Consumption 100 VAC to 120 VAC 8 VA (3 W)
10 VA (4 W)
15 VA (7 W)
7 VA (3 W)
8 VA (3 W)
10 VA (5 W)
15 VA (6 W)
19 VA (9 W)
200 VAC to 240 VAC 11 VA (3 W)
13 VA (4 W)
20 VA (8 W)
11 VA (4 W)
11 VA (4 W)
15 VA (7 W)
18 VA (8 W)
22 VA (9 W)
Dimensions (W x H x D)
480 x 44 x 27 mm
480 x 44 x 27 mm
480 x 88 x 27 mm
430 x 44 x 34 mm
430 x 44 x 34 mm
430 x 44 x 42 mm
430 x 44 x 42 mm
430 x 88 x 44 mm
Weight
1 kg
1 kg
1.5 kg
1 kg
1 kg
2 kg
2 kg
3 kg
Consumables
AC adapter: Replace every 5 years
Accessories
AC adapter and AC cable x 1 DC adapter retaining clip x 1 Tool used to change button labels x1
Options
DC adapter retaining clip (screw-in type) x 1
AC adapter and AC cable x 1 DC adapter retaining clip x1 Rack mount brackets LAN cable Tool used to change button labels x1
Table-top model
Interface expansion unit
Remote control relay unit
Model Name
MFR-16RUTA
Model Name
MFR-GPI
Buttons/Colors
16 buttons (3-color: red/green/orange) user assignable
Number of Connections
Max. 128 units (including MU, remote control and GPI units)
MFR-RULINK
Interfaces MFR-LAN
10/100BASE-TX RJ-45 x1*
10/100/1000BASE-T RJ-45 x1* 10/100/1000BASE-T RJ-45 x1*
*(Ethernet hub is required for main and multiple unit connections.) (for connection to RU)
3 function buttons (PAGE x2 / LOCK x1) Name display
MFR-TALM
Available (Displayed above each button) OLED display x16 (Max. 7 characters x2 lines)
Service
RS-232C: 9-pin D-sub None (male) x1 (for maintenance)
None
PC-LAN REF IN
None None
10/100BASE-TX RJ-45 x1 (for PC or other external devices) None None
Rotary selector
Available
GPI IN / TALLY OUT
Max. 128 units (including MU, remote control and GPI units)
37-pin D-sub (female) x1 32-input/output (user assignable)
None
Number of Connections
37-pin D-sub (female) x4 128-input/output (user assignable)
RS-422
None
9-pin D-sub (male) x4
None
Serial 1-4
RS-232C/422 (selectable): 9-pin D-sub (male) x4
None
None
Interfaces MFR-LAN
Service
10/100BASE-TX RJ-45 x1 (for connection to MU; network hub required for connecting to multiple MUs)
Temperature / Humidity 0 °C to 40 °C / 30 % to 85 % (no condensation)
None
Consumption
Power
+12 VDC Pin-connector x2 (redundant power supply as standard)
Temperature / Humidity 0 °C to 40 °C / 30 % to 85 % (no condensation)
100 VAC to 120 VAC 8 VA (4 W)
17 VA (9 W)
17 VA (9 W)
Power Consumption
200 VAC to 240 VAC 13 VA (6W)
20 VA (9 W)
20 VA (9 W)
Demensions (W x H x D) 430 x 44 x 110 mm
212 x 44 x 161 mm
212 x 44 x 161 mm
100 VAC to 120 VAC 12 VA (5W)
Weight
2 kg
2 kg
2 kg
200 VAC to 240 VAC 15 VA (6W)
Consumables
AC adaptor: replace every 5 years
Accessories
AC adapter and AC cable x1 AC adapter and AC cable x1 AC adapter and AC cable x1 DC adapter retaining clip x1 set DC adapter retaining clip x1 set DC adapter retaining clip x1 set Rack mount brackets x1 set Operation manual x1 LAN cable x1
Option
DC adapter retaining clip (screw-in type) x 1
+12 VDC Pin-connector x1
Demensions (W x H x D) 215 (W) x 88 (H) x 43 (D) mm Weight
1 kg
Consumables
AC adaptor: Replace every 5 years
Accessories
AC adapter and AC cable x1 DC adapter retaining clip x1 LAN cable Tool used to change button labels x1 DC adapter retaining clip (screw-in type) x 1
Options
Rack mount brackets x1 set DC adapter retaining clip (screw-in type) x 1
ISO 9001 and 14001 certified (Sakura R&D)
http://www.for-a.com/
Head Office: 3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan FOR-A UK Limited:
Tel: +44-(0)20-3044-2935
FOR-A Corporation of America East Coast Office:
FOR-A Italia S.r.l.:
Tel: +39-039-881-086/103
FOR-A Corporation of America Distribution & Service Center: Tel: +1-352-371-1505
FOR-A Corporation of Korea:
FOR-A Corporation of America:
11155 Knott Ave. Suite G&H, Cypress, CA 90630, U.S.A.
Tel: +1-714-894-3311
Tel: +1-201-944-1120 2 Executive Drive, Suite 670, Fort Lee Executive Park, Fort Lee, NJ 07024, U.S.A. 2400 N.E. Waldo Road, Gainesville, FL 32609, U.S.A.
Trident Court, 1 Oakcroft Road, Chessington, KT9 1BD, UK Via Volturno, 37, 20861, Brugherio MB, Italy
Tel: +82-(0)2-2637-0761 1007, 57-5, Yangsan-ro, Yeongdeungpo-gu, Seoul 150-103, Korea
FOR-A Corporation of America Miami Office:
Tel: +1-305-931-1700
FOR-A China Limited:
FOR-A Corporation of Canada:
Tel: +1-416-977-0343
FOR-A Middle East-Africa Office:
FOR-A Europe S.r.l.:
Tel: +39-039-879-778
Agiv (India) Private Limited (FOR-A India):
5200 Blue Lagoon Drive, Suite 760, Miami, FL 33126, U.S.A. 1131A, Leslie Street #209, Toronto, Ontario, M3C 3L8, CANADA Via Volturno, 37, 20861 Brugherio MB, Italy
Tel: +86-(0)10-8721-6023 708B Huateng Building, No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China Tel: +971-(0)4-551-5830 Dubai Media City, Aurora Tower, Office 1407, P.O. Box 502688, Dubai, UAE
85, V.N. Purav Marg Sion-Chunabhatti (E) Mumbai - 400 022
Tel: +91-22-2405-1258
© 2015 FOR-A Company Ltd. FOR-A is a registered trademark of FOR-A Company Ltd. Design and specifications subject to change without notice. Printed in Japan. 1512NPC