Preview only show first 10 pages with watermark. For full document please download

Datasheet - Shf Communication Technologies Ag

   EMBED


Share

Transcript

SHF Communication Technologies AG Wilhelm-von-Siemens-Str. 23 • Aufgang D • 12277 Berlin – Marienfelde • Germany Phone ++49 30 / 772 05 10 • Fax ++49 30 / 753 10 78 E-Mail: [email protected] • Web: http://www.shf.de Datasheet SHF DCR65 50Ω DC Return Resonance free transmission performance Innovative construction – Patent pending Specifications – SHF DCR65 Parameter Symbol Unit Min High frequency 3 dB point fHIGH GHz 65 Low frequency 3 dB point fLOW kHz 30 at 100mA Insertion loss S21 dB 1.5 <60 GHz Input return loss S11 dB -17 -10 <25 GHz <65 GHz Group delay ps Maximum input power Typ Max 20 40 Conditions <45 GHz <65 GHz aperture 100MHz Pmax dBm 30 Rise time/Fall time tr/tf ps 5 Maximum voltage across device Vdiff V 16 10…90% Input connector V (1.85 mm) Output connector V (1.85 mm) Dimensions (LxWxH) mm 31x13x12.6 Insertion loss 0 S21 [dB] -1 -2 -3 -4 -5 0 10 20 30 40 50 60 Frequency [GHz] S21 gemessen von 1KHz ... 40MHz 0 S21 [dB] -1 -2 -3 -4 -5 0.01 0.05 0.10 0.50 1.00 5.00 10.00 Frequency [MHz] SHF reserves the right to change specifications and design without notice – SHF DCR65 – Rev002 – 27/Mar/2007 Page 2/4 Input return loss S11 (HF-DC-Port-Seite) gemessen von 1KHz ... 40MHz 0 0 -10 -10 S11 [dB] S11 [dB] -20 -30 -20 -40 -50 -60 0 -30 10 20 30 40 50 60 0.001 0.010 0.100 1.000 10.000 Frequency [MHz] Frequency [GHz] Group delay 50 Group delay valiation [ps] 40 30 20 10 0 -10 -20 -30 -40 -50 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Frequency [GHz] Aperture of group delay measurement: 100MHz Phase response [°] Phase response 20 15 10 5 0 -5 -10 -15 -20 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Frequency [GHz] SHF reserves the right to change specifications and design without notice – SHF DCR65 – Rev002 – 27/Mar/2007 Page 3/4 Outline diagram Applications 12,1  Optical Communications SHF DCR-65 A 13 Research and Development 16V/0,4A SN XXXX 50 kHz-65 GHz 11,3 High-Speed Pulse Experiments Data Transmission 13 The following combinations of connectors are available. 6,3 31 12,6 12,1 Please specify with your order. 13 SHF DCR-65 B 16V/0,4A 50 kHz-65 GHz 11,3 SN XXXX 13 6,3 12,6 12,1 31 13 SHF DCR-65 C 16V/0,4A 50 kHz-65 GHz 12,1 SN XXXX 13 6,3 12,6 11,3 31 13 SHF DCR-65 D 16V/0,4A 50 kHz-65 GHz 11,3 SN XXXX 13 31 6,3 All dimensions in mm SHF reserves the right to change specifications and design without notice – SHF DCR65 – Rev002 – 27/Mar/2007 12,6 Page 4/4