Preview only show first 10 pages with watermark. For full document please download

Datasheet Z109reg2

   EMBED


Share

Transcript

Z109REG2 High performance universal converter Z109REG2 is an advanced universal converter able to manage all analog signals (mA, V, PT100, Pt1000, Pt500, Ni100, TCs, Ohm) and convert / isolate it into mA/V standard signals. The device can be configured through dip-switches, PC software or handheld device. A digital contact is available as ALARM or STROBE (multiplexing). It can be requested with low or high power supply. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas. Vac / dc Power Supply 1 Input Ouput 1 V V Technical Specifications Electrical Specifications Output Power supply 10..40 Vdc / 19..28 Vac / 50-60 Hz Channel Numbers Power consumption 2,5 W Voltage Isolation 1.500 Vac (3 way) Power transducers Yes Current Status Indicators Power supply, error, data transmission, data reception, input status Relay Protection Degree IP20 Standard Thermomechanical Specifications Operating -10..+60 °C Temperature Dimension (W x H x D) 17.5 x 100 x 112 mm Accuracy 0,1% Response time 35 ms (11 bit)..140 ms (16 bit) Dip- switches EASY_Z109 (PC software) Test-3 (hand held calibrator) 35 mm DIN rail guide Setting Mounting Input Channel Numbers Potentiometer 1 (mV, V) Bipolar from 75 mV to 20 V Resolution 15 bit + sign Bipolar up to 20 mA Resolution 1 μA Pt100, Pt500, Pt1000, Ni100, KTY81,KTY84, NTC Measure 3, 4 wires Range: -200..600 °C Resolution 0,1°C Type J, K, R, S, T, E, B, N Resolution 2,5 μV 500 Ω ..100 kΩ Rheostat 500 Ω..25 kΩ Strobe Alternative to the relay output Voltage Current Rtd Thermocouple 1 4 scales: 0..1, 0..5, 0..10, 2..10 V Min load resistance: 2.000 Ω 2 scales: 0/4..20 mA (active/passive) Max load resistance: 600 Ω Alternative to the strobe NC / NA in case of alarm Approval CE, UL-CSA EN 50081-2; EN 55011; EN 50082-2; EN 61000-2-2/4; EN 50140/141; EN 61010-1 Norms order codes Code Description Z109REG2 Z109REG2-H High performance universal converter, Power supply 10..40 Vdc / 19..28 Vac High performance universal converter, Power supply 85..265 Vac/Vdc accessories & software PM001601 Programming cable TEST-3 Handheld configurator EASY SETUP Programming software www.seneca.it analog universal input high class accuracy fast response time wide operating temperature mA, V, Ohm, RTD, TC 0,1% 35 ms (11 bit + segno) -20..+60°C transducer power supply high resolution auxiliary contacts Approvals 16 bit Strobe Input SPDT relay Output 20 Vcd, 20 mA G2 Z109RE 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 Z109REG2 Z109REG2 Z109REG2 7 8 9 10 11 12 7 8 9 10 11 12 7 8 9 10 11 12 APPLICATION NOTE Multiplexer strobe Trip amplifier 2 Z109REG G2 9..40 Vdc 19..28 Vac Z109RE 1 2 3 4 5 6 POWER ERROR 1 2 3 4 5 6 POWER ERROR 1 2 3 4 5 6 POWER ERROR COM COM COM Z109REG2 7 8 9 10 11 12 EG2 Z109R 1 2 3 6 74 85 9 10 11 12 EG2 Z109R 1 2 3 47 58 69 1 2 3 4 5 6 10 11 12 Pt100 Z109REG2 Z109REG2 Z109REG2 7 8 9 10 11 12 7 8 9 10 11 12 7 8 9 10 11 12 1 2 3 4 5 6 POWER +25 °C ERROR COM Z109REG2 7 8 9 10 11 12 4...20 Signal retransmission 1 мА Signal retransmission 2 Pt100 Pt100 Pt100 1 2 3 4 5 6 3 1 2 31 2 6 4 5 64 5 POWER 24 V ERROR POWER ERROR POWER ERROR COM COM C 5 °5C° +2+2 COM Z109REG2 7 8 9 10 11 12 Z109REG2 Z109REG27 24 V 8 9 11 12 7 8 910 10 11 12 4...20 4...2 4...20 0 мА мА мА Configuration • Input type • Zero and Span • Output type • Scale inversion 2- HANDHELD Pt100 Pt100 • Min / max range scale; digital filter; square root extraction • Fault sensor • Analog scale; error analog output value • Rejection frequency (50 – 60 Hz) 4...20 • Sampling time / Resolution мА • Measure 2, 3, 4 wires for RTD 4...20 alarm control, strobe • Relay мА configuration 1 2 3 4 5 6 POWER ERROR 1 2 3 4 5 6 COM POWER Z109REG2 ERROR 7 8 9 10 11 12 COM Z109REG2 7 8 9 10 11 12 3 - SOFTWARE • Min / max range scale; digital filter; square root extraction • Fault sensor • Analog scale; error analog output value • Rejection frequency (50 – 60 Hz) • Sampling time / Resolution • Measure 2, 3, 4 wires for RTD • Relay alarm control, strobe configuration via Germania, 34 • 35127 Padova - (I) - Tel. +39 049 87.05.359 (.408) Fax +39 049 87.06.287 • www.seneca.it • [email protected] The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, SENECA assumes no liability resulting from errors or omissions, or from the use of the information contained herein. Publication Z109REG2 – March 2013 1- DIP-SWITCHES