Preview only show first 10 pages with watermark. For full document please download

Datasheet_crm_4

   EMBED


Share

Transcript

Staircase switch CRM-4 • Used for delayed switching of lights in the corridors, entrances, stairways, halls or for delayed finish of fans (WC, bathroom, etc.). • It is controlled by a button or by several buttons from more places (connected in parallel), buttons can be equipped by glow lamps (max. 20 pcs of glow lamps). • Output relay contact 16 A/AC1 with surge current up to 80 A enables switching of el. bulbs and fluorescent lamps. • Operating system switch: AUTO – normal function according to set time. OFF – permanently OFF (e.g. when changing bulbs). ON – permanently ON (e.g. while cleaning, servicing). • Time range: 0.5 - 10 min. • Time setting by potentiometer. • Supply voltage : AC 230 V. • Protection against button blocking (e.g. a match inserted in a button). • 1- MODULE, DIN rail mounting. 16 18 A1 16 18 A1 S  15 A2 Un S  A2 load 15 VS116U VS308U Supply voltage: AC/DC 12-240 V Output contact: 1x changeover/SPDT 16 A. Supply voltage: AC/DC 12-240 V Output contacts: 3x changeover/ TPDT 8 A. 750L 782L Circuit connection 3-wire connection 4- wire connection L L N N A1 S A2 A1 S A2 782L ES-15/4N - socket 750L ES-11- socket Power relays plug-in Output contacts: 4 x changeover contact/ SPDT 6 A. Plug-in type. Max. voltage: 12 A Weight: 59 g Mounting to DIN rail Intended for 4-contact relay. Power relays plug-in Output contacts: 3 x changeover contact / SPDT 10 A. Plug-in type. Max. current: 10 A Weight: 60 g Monting to DIN rail Intended for 3-contact relay. Overview table MINI VS116K 1M-DIN VS116U 1M-DIN VS308K 1M-DIN VS308U 1M-DIN VS316/24 1M-DIN VS316/230 1M-DIN 782L PLUG-IN 750L PLUG-IN x x Page of catalogue VS116B/230 Designation Function Paralel diode 15 16 18 RC unit Other features U AUTO OFF position switches ON S t t Description Supply terminals A1 S  A2 Controlling contact Output indication Supply indication Operating system swich Time setting 15 30 Supply voltage: AC 230 V Output contacts: 3x changeover/ TPDT 16 A, possibility to be connected into 3-phase circuit. Connection t -20 °C to +55 °C (-4 °F to 131 °F) -30 °C to +70 °C (-22 °F to 158 °F) 4 kV (supply - output) any DIN rail EN 60715 IP 40 from front panel / IP 20 terminals III. 2 solid wire max.1x 2.5 or 2x1.5/ with sleeve max. 1x2.5 (AWG 12) 90 x 17.6 x 64 mm (3.5˝ x 0.7˝ x 2.5˝) 62 g (2.2 oz.) EN 60669-2-3, EN 61010-1 VS316/230 Supply voltage: AC/DC 24 V Output contacts: 3x changeover/TPDT 16 A, possibility to be connected into 3-phase circuit. It is possible to connect load between S-A2 (e.g. contactor, control of light or any other device), without disturbing a correct function of relay (load is energized while the switch is ON). 15 16 18 AC 230 V AC 0.53 VA Yes A1-S Yes max. amount 35 pcs (measured with glow lamp 0.68mA/230V AC) min. 25 ms / max. unlimited max. 150 ms VS316/24 Supply voltage: AC 230 V and AC/DC 24 V Output contacts: 3x changeover/ TPDT 8A. LED signal light 1x changeover/SPDT (AgSnO2) 16 A / AC1 4000 VA / AC1, 384 W / DC 30 A / <3 s 250 V AC1 / 24 V DC 500 mW red LED 3x107 0.7x105 VS308K Supply voltage: AC 230 V and AC/DC 24 V Output contact: 1x changeover/ SPDT 16 A. Output contact delay off reacting to control contact switching A1 - A2 AC 230 V / 50 - 60 Hz AC max. 12 VA / 1.8 W -15 %; +10 % green LED 0.5 - 10 min potentiometer 10 % - mechanical setting 5 % - set value stability 0.05 % / °C, at = 20 °C (0.05 % / °F, at = 68 °F) Symbol VS116K Supply voltage: AC 230 V Output contact: 1x changeover/ SPDT 16 A. Coil voltage Function: Supply terminals: Voltage range: Burden: Supply voltage tolerance: Supply indication: Time ranges: Time setting: Time deviation: Repeat accuracy: Temperature coefficient: Output Number of contacts: Current rating: Breaking capacity: Inrush current: Switching voltage: Min. breaking capacity DC: Output indication: Mechanical life: Electrical life (AC1): Control Control voltage: Power on input: Load between S-A2: Control terminals: Glow tubes connetions: Max. amount of glow lamps connected to controlling input: Impulse length: Reset time: Other information Operating temperature: Storage temperature: Electrical strength: Operating position: Mounting: Protection degree: Overvoltage category: Pollution degree: Max. cable size (mm2): Dimensions: Weight: Standards: CRM-4 VS116B/230 VS(U) Design Technical parameters VS(B,K) Type EAN code CRM-4 /230V: 8595188115605 Auxiliary and Power relays 16 18 Output contact 1x16 A changeover/ SPDT 1x16 A changeover/ AC 230 and AC/DC 24 V SPDT 1x16 A changeover/ AC/DC 12..240 V SPDT 3x8 A changeover/ AC 230 and AC/DC 24 V TPDT 3x8 A changeover/ AC/DC 12..240 V TPDT 3x16 A changeover/ AC/DC 24 V TPDT 3x16 A changeover/ AC 230 V TPDT 4x6 A changeover/ AC 6-230 V, DC 6-110 V 4PDT AC 6-230 V, 3x10 A changeover/ DC 6-110V 3PDT AC 230 V/50-60 Hz VS116/B230 MINI, with installation into junction box or ceiling that allows control of lights, shades or awnings drives 32 as a separation relay (4kV), direct switching of appliances up to 4000VA (e.g. heaters), well visible signalization, noiseless 32 as VS116K, but multivoltage supply coil 32 a “multiplication” of contacts, 3x changeover contact/ 3PDT only in 1-MODULE, well visible signalization, noiseless 32 as VS308K, but multivoltage supply coil 32 3x changeover contact in 1-MODULE, possibility of “multiplication” of contacts and in the same time possibility of switching high output, possibility of 3 phase switching 32 as VS316/24, but AC 230V 32 x x compact small relay for installation into plug relay, basic version equipped by LED indication, detent and testing lever 34 x x as 782, but into 11-pin round socket, 3x changeover contact / 3PDT 10A/250V 34 More about contact loadability on page 131-132. 31