104 T001 GB 12/06 CO OSRAM HID Subject to modification without notice. Errors and omissions excepted
z Printed on paper treated with chlorine-free bleach
www.osram.com
POWERBALL® HCI®
Technical Information
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-TF, TC
1
2 HCI-TF w 20 W Ne 830 WDL PB UVS, PB MT/UB-20/30/1BH/E-GU6.5-13/57 20 90 3.6/5 0.22 1700 85 830 WDL 3000 > 80 >8 <2 GU6.5 13 57 31 universal 12000 – – ECG HCI-TF 20/830 WDL PB 4008321907615 12 1 2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-TC 20 W 830 WDL PB UVS, PB MT/UB-20/30/1BH/E-G8.5-15/81 20 100 3.6/5 0.22 1700 85 830 WDL 3000 82 > 21 < 0.4 G8.5 15 81 52 universal 12000 400 280 ECG HCI-TC 20/830 WDL PB 4008321052216 12 2 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
4000
6000 Hours burned
8000
10000
80 70 60 50
12000
0
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
4000
6000 Hours burned
8000
10000
12000
Luminous flux in %
Survival rate in %
90
80 70 60
2
10000
12000
0
2000
4000
6000 Hours burned
8000
10000
12000
8000
10000
12000
Luminous flux behaviour HCI-TC
90
Downloaded from DatasheetLib.com - datasheet search engine
8000
60 50
100
2000
6000 Hours burned
70
Survival rate HCI-TC
0
4000
80
100
50
2000
Luminous flux behaviour HCI-TC 20 W
Survival rate HCI-TC 20 W 100
50
HCI-TC 35 W 942 NDL PB UVS, PB MT/UB-35/42/1AH-G8.5-15/81 37 90 3.6/5 0.5 3200 86 942 NDL 4200 90 > 21 < 0.4 G8.5 15 81 52 universal 12000 450 300 6 HCI-TC 35/942 NDL PB 4050300873725 12 2 1/2
Luminous flux behaviour HCI-TF
Survival rate HCI-TF 100
50
HCI-TC 35 W 830 WDL PB UVS, PB MT/UB-35/30/1BH-G8.5-15/81 37 90 3.6/5 0.5 3400 92 830 WDL 3000 82 > 21 < 0.4 G8.5 15 81 52 universal 12000 450 300 6 HCI-TC 35/830 WDL PB 4050300873763 12 2 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
POWERBALL® HCI®-TC
1 HCI-TC 70 W 830 WDL PB UVS, PB MT/UB-70/30/1BH-G8.5-15/81 72 90 3.6/5 0.96 6900 96 830 WDL 3000 88 > 21 < 0.4 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/830 WDL PB 4008321907639 12 1 1/2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-TC w 70 W Ne 942 NDL PB UVS, PB in development 72 91 3.6/5 0.96 6600 92 942 NDL 4200 94 >8 <2 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/942 NDL PB 4008321907646 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
HCI-TC 70 W 942 NDL UVS MT/UB-70/42/1AH-G8.5-15/81 72 91 3.6/5 0.96 6300 88 942 NDL 4200 ≥ 90 > 22 < 0.37 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/942 NDL 4050300873794 12 1 1/2
Luminous flux behaviour HCI-TC
Survival rate HCI-TC 100
50
HCI-TC 70 W 830 WDL UVS MT/UB-70/30/1BH-G8.5-15/81 72 90 3.6/4.5 0.96 6600 92 830 WDL 3000 81 > 24 < 0.35 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/830 WDL 4050300873831 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
3
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-T
1 HCI-T 35 W 830 WDL PB UVS, PB MT/UB-35/30/1BH-G12-19/100 W 37 V 90 kVs 3.6/5 A 0.5 lm 3400 lm/W 92 830 WDL K 3000 Ra 84 h > 21 2 mW/m · 1000 lx < 0.4 G12 mm 19 mm 100 mm 56 universal h 12000 °C 450 °C 280 µF 6 HCI-T 35/830 WDL PB 4008321005625 Qty 12 No. 1 Fig. no. 1/2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26)
HCI-T 35 W 942 NDL PB UVS, PB MT/UB-35/42/1AH-G12-19/100 37 90 3.6/5 0.5 3300 89 942 NDL 4200 90 > 21 < 0.4 G12 19 100 56 universal 12000 450 280 6 HCI-T 35/942 NDL PB 4050300873480 12 1 1/2
HCI-T 70 W 830 WDL PB UVS, PB MT/UB-70/30/1BH-G12-19/100 72 100 3.6/5 0.96 7000 97 830 WDL 3000 87 > 47 < 0.18 G12 19 100 56 universal 12000 500 280 12 HCI-T 70/830 WDL PB 4050300873664 12 1 1/2
100
90
90
80 70 60 50
0
2000
4
Downloaded from DatasheetLib.com - datasheet search engine
HCI-T w 100 W Ne 830 WDL PB UVS, PB MT/UB-100/30/1BH-G12-19/100 100 100 3.6/5 1.2 9500 95 830 WDL 3000 86 >8 <2 G12 19 100 56 universal 12000 500 280 16 HCI-T 100/830 WDL PB 4008321907660 12 1 1/2
Luminous flux behaviour HCI-T
100 Luminous flux in %
Survival rate in %
Survival rate HCI-T
HCI-T w 70 W Ne 942 NDL PB UVS, PB MT/UB-70/42/1AH-G12-19/100 72 90 3.6/5 0.96 6700 93 942 NDL 4200 93 > 27 < 0.32 G12 19 100 56 universal 12000 500 280 12 HCI-T 70/942 NDL PB 4050300873626 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
POWERBALL® HCI®-T, TM
1
2 HCI-T w 100 W Ne 942 NDL PB UVS, PB MT/UB-100/42/1AH-G12-19/100 W 100 V 100 kVs 3.6/5 A 1.2 lm 9300 lm/W 93 942 NDL K 4200 Ra > 90 h >8 2 mW/m · 1000 lx < 2 G12 mm 19 mm 100 mm 56 universal h 12000 °C 500 °C 280 µF 16 HCI-T 100/942 NDL PB 4008321907677 Qty 12 No. 1 Fig. no. 1/2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26)
HCI-T 150 W 830 WDL PB UVS, PB MT/UB-150/30/1BH-G12-25/105 145 100 3.6/5 1.8 15500 107 830 WDL 3000 86 > 50 < 0.06 G12 25 105 56 universal 12000 550 280 20 HCI-T 150/830 WDL PB 4050300873435 12 1 1/2
HCI-T 150 W 942 NDL PB UVS, PB MT/UB-150/42/1AH-G12-25/105 145 92 3.6/5 1.8 14500 100 942 NDL 4200 96 > 50 < 0.12 G12 25 105 56 universal 12000 550 280 20 HCI-T 150/942 NDL PB 4050300873336 12 1 1/2
100
90
90
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
80 70 60 50
12000
0
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
2000
4000
6000 Hours burned
8000
10000
12000
8000
10000
12000
Luminous flux behaviour HCI-TM
Survival rate HCI-TM 100
50
HCI-TM w 250 W Ne 942 NDL PB UVS, PB MT/UB-250/42/1AH-G22-34/175 249 98 3.6/5 3.0 25000 100 942 NDL 4200 98 >8 <2 G22 28 175 90 universal 12000 580 280 32 HCI-TM 250/942 NDL PB 4008321907684 10 2 1
Luminous flux behaviour HCI-T
100 Luminous flux in %
Survival rate in %
Survival rate HCI-T
HCI-TM w 250 W Ne 830 WDL PB UVS, PB MT/UB-250/30/1BH-G22-34/175 248 101 3.6/5 2.9 26000 107 830 WDL 3000 92 > 300 < 0.028 G22 28 175 90 universal 12000 580 280 32 HCI-TM 250/830 WDL PB 4050300977263 10 2 1
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
5
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-T, TC, Shoplight
1
2 HCI-T w 35 W Ne 930 WDL PB UVS, PB, Shoplight MT/UB-35/30/1AH-G12-19/100 39 92 3.6/5 0.5 2800 79 930 WDL 3000 92 >8 <2 G12 19 100 56 universal 12000 450 300 6 HCI-T 35/930 WDL PB Shop 4008321108166 12 1 1/2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-T 70 W 930 WDL PB UVS, PB, Shoplight MT/UB-70/30/1AH-G12-19/100 73 90 3.6/5 0.96 6400 88 930 WDL 3000 94 > 21 < 0.4 G12 19 100 56 universal 12000 550 300 12 HCI-T 70/930 WDL PB Shop 4050300983134 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
6
Downloaded from DatasheetLib.com - datasheet search engine
4000
HCI-TC 70 W 930 WDL PB UVS, PB, Shoplight MT/UB-70/30/1AH-G8.5-15/81 73 95 3.6/5 0.96 6300 86 930 WDL 3000 95 > 24 < 0.35 G8.5 15 81 52 universal 12000 550 300 12 HCI-TC 70/930 WDL PB Shop 4050300983110 12 2 1/2
Luminous flux behaviour Shoplight
Survival rate Shoplight 100
50
HCI-TC w 35 W Ne 930 WDL PB UVS, PB, Shoplight MT/UB-35/30/1AH-G8.5-15/81 37 92 3.6/5 0.5 2800 79 930 WDL 3000 92 >8 <2 G8.5 15 81 52 universal 12000 450 300 6 HCI-TC 35/930 WDL PB Shop 4008321108142 12 2 1/2
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
a
POWERBALL® HCI®-T, TT
1 HCI-T 250 W 830 WDL PB UVS, PB MT/UB-250/30/1BH-E40-46/226 245 105 3.6/5 2.8 25800 105 830 WDL 3000 87 > 50 < 0.04 E40 46 226 150 universal 12000 500 250 32 HCI-T 250/830 WDL PB 4050300636849 12 1 1
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-T w 250 W Ne 942 NDL PB UVS, PB MT/UB-250/42/1AH-E40-46/226 250 100 3.6/5 2.8 25000 100 942 NDL 4200 96 >8 <2 E40 46 226 150 universal 12000 500 250 32 HCI-T 250/942 NDL PB 4008321908308 12 1 1
100
90
90
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
80 70 60 50
12000
0
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
2000
4000
6000 Hours burned
8000
10000
12000
8000
10000
12000
Luminous flux behaviour HCI-TT
Survival rate HCI-TT 100
50
HCI-TT 150 W 830 WDL PB UVS, PB MT/UB-150/30/1BH-E40-46/204 148 95 2.75/5 1.8 14500 98 830 WDL 3000 83 > 50 < 0.04 E40 46 204 132 universal 15000 400 210 20 HCI-TT 150/830 WDL PB 4050300784144 12 1 1
Luminous flux behaviour HCI-T 250 W
100 Luminous flux in %
Survival rate in %
Survival rate HCI-T 250 W
HCI-TT 70 W 830 WDL PB UVS, PB MT/UB-70/30/1BH-E27-30/150 74 90 1.8/5 0.92 7000 95 830 WDL 3000 86 > 47 < 0.18 E27 30 150 102 universal 15000 350 210 12 HCI-TT 70/830 WDL PB 4050300784120 12 1 1
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
7
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-T/P
1 HCI-T/P 70 W 830 WDL PB clear UVS, PB MTS/UB-70/30/ 1B-H-E27-32/ 125 W 73 V 90 kVs 3.6/5 A 0.98 lm 6500 lm/W 89 830 WDL K 3000 Ra > 80 h > 47 2 mW/m · 1000 lx < 0.18 E27 mm 32 mm 125 mm 89 universal h 12000 °C 330 °C 190 µF 12 HCI-T/P 70/830 WDL PB clear 4008321907714 Qty 12 No. 1 Fig. no. 1/2
New
Type ILCOS
Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
EAN Standard pack Figure Circuit (see page 26)
HCI-T/P 70 W 830 WDL PB coated UVS, PB MTS coated/ UB-70/30/1BH-E27-32/125 73 90 3.6/5 0.98 6400 88 830 WDL 3000 > 80 > 47 < 0.18 E27 32 125 89 universal 12000 330 190 12 HCI-T/P 70/830 WDL PB coated 4008321907721 12 1 1/2
HCI-T/P 70 W 942 NDL PB clear UVS, PB MTS/UB-70/42/ 1A-H-E27-32/ 125 73 90 3.6/5 0.98 6100 84 942 NDL 4200 > 90 >8 <2 E27 32 125 89 universal 12000 330 190 12 HCI-T/P 70/942 NDL PB clear 4008321907738 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
8
Downloaded from DatasheetLib.com - datasheet search engine
HCI-T/P 100 W 830 WDL PB clear UVS, PB MTS/UB-100/30/ 1B-H-E27-40/ 140 100 95 3.6/5 1.2 9000 90 830 WDL 3000 > 80 >8 <2 E27 40 140 89 universal 12000 330 190 16 HCI-T/P 100/830 WDL PB clear 4008321907752 12 1 1/2
HCI-T/P 100 W 830 WDL PB coated UVS, PB MTS coated/ UB-100/30/1BH-E27-40/140 100 95 3.6/5 1.2 8500 85 830 WDL 3000 > 80 >8 <2 E27 40 140 89 universal 12000 330 190 16 HCI-T/P 100/830 WDL PB coated 4008321907769 12 1 1/2
Luminous flux behaviour HCI-T/P
Survival rate HCI-T/P 100
50
HCI-T/P 70 W 942 NDL PB coated UVS, PB MTS coated/ UB-70/42/1AH-E27-32/125 73 90 3.6/5 0.98 6000 82 942 NDL 4200 > 90 >8 <2 E27 32 125 89 universal 12000 330 190 12 HCI-T/P 70/942 NDL PB coated 4008321907745 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
POWERBALL® HCI®-T/P
1 HCI-T/P 100 W 942 NDL PB clear UVS, PB MTS/UB-100/42/ 1A-H-E27-40/ 140 W 100 V 95 kVs 3.6/5 A 1.2 lm 8800 lm/W 88 942 NDL K 4200 Ra > 90 h >8 2 mW/m · 1000 lx < 2 E27 mm 40 mm 140 mm 89 universal h 12000 °C 330 °C 190 µF 16 HCI-T/P 100/942 NDL PB clear 4008321907776 Qty 12 No. 1 Fig. no. 1/2
New
Type ILCOS
Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
EAN Standard pack Figure Circuit (see page 26)
HCI-T/P 100 W 942 NDL PB coated UVS, PB MTS coated/ UB-100/42/1AH-E27-40/140 100 95 3.6/5 1.2 8300 83 942 NDL 4200 > 90 >8 <2 E27 40 140 89 universal 12000 330 190 16 HCI-T/P 100/942 NDL PB coated 4008321907783 12 1 1/2
HCI-T/P 150 W 830 WDL PB clear UVS, PB MTS/UB-150/30/ 1B-H-E27-40/ 140 145 95 3.6/5 1.8 14200 98 830 WDL 3000 > 80 > 50 < 0.06 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/830 WDL PB clear 4008321907790 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
HCI-T/P 150 W 942 NDL PB clear UVS, PB MTS/UB-150/42/ 1A-H-E27-40/ 140 145 95 3.6/5 1.8 14000 97 942 NDL 4200 > 90 > 50 < 0.12 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/942 NDL PB clear 4008321907813 12 1 1/2
HCI-T/P 150 W 942 NDL PB coated UVS, PB MTS coated/ UB-150/42/1AH-E27-40/140 145 95 3.6/5 1.8 13300 92 942 NDL 4200 > 90 > 50 < 0.12 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/942 NDL PB coated 4008321907820 12 1 1/2
Luminous flux behaviour HCI-T/P
Survival rate HCI-T/P 100
50
HCI-T/P 150 W 830 WDL PB coated UVS, PB MTS coated/ UB-150/30/1BH-E27-40/140 145 95 3.6/5 1.8 14000 97 830 WDL 3000 > 80 > 50 < 0.06 E27 40 140 89 universal 12000 330 190 20 HCI-T/P 150/830 WDL PB coated 4008321907806 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
9
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-TS
1 HCI-TS 70 W 830 WDL PB UVS, PB MD/UB-70/30/1BH-RX7s-21/114.2/P45 72 95 3.6/4.5 0.95 6900 96 830 WDL 3000 88 > 18 < 0.45 RX7s 21 114.2 57 p 45 12000 500 280 12 HCI-TS 70/830 WDL PB 4050300784069 12 1 1/2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-TS 70 W 942 NDL PB UVS, PB MD/UB-70/42/1AH-RX7s-21/114.2/P45 74 94 3.6/5 0.98 6700 91 942 NDL 4200 95 > 29.7 < 0.28 RX7s 21 114.2 57 p 45 12000 500 280 12 HCI-TS 70/942 NDL PB 4050300784106 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
10
Downloaded from DatasheetLib.com - datasheet search engine
HCI-TS 150 W 942 NDL PB UVS, PB MD/UB-150/42/1AH-RX7s24-24/132/P45 144 96 3.6/5 1.8 14200 99 942 NDL 4200 97 > 26 < 0.32 RX7s-24 24 132 66 p 45 12000 650 280 20 HCI-TS 150/942 NDL PB 4050300784007 12 1 1/2
Luminous flux behaviour HCI-TS
Survival rate HCI-TS 100
50
HCI-TS 150 W 830 WDL PB UVS, PB MD/UB-150/30/1BH-RX7s24-24/132/P45 144 100 3.6/5 1.8 14800 103 830 WDL 3000 90 > 50 < 0.4 RX7s-24 24 132 66 p 45 12000 650 280 20 HCI-TS 150/830 WDL PB 4050300783987 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
POWERBALL® HCI®-TS, E
1
2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-TS 250 W 830 WDL PB
HCI-TS w 250 W Ne 942 NDL PB
UVS, PB MD/UB-250/30/1BH-Fc2-25/163/P45 245 100 3.6/5 3.0 25000 102 830 WDL 3000 90 > 50 < 0.15 Fc2 25 163 81.5 p 45 12000 650 280 32 HCI-TS 250/830 WDL PB 4050300637730 12 1 1
UVS, PB MD/UB-250/42/1AH-Fc2-25/163/P45 245 100 3.6/5 3.0 23000 94 942 NDL 4200 > 90 >8 <2 Fc2 25 163 81.5 p 45 12000 650 280 32 HCI-TS 250/942 NDL PB 4008321907707 12 1 1
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
HCI-E w 250 W Ne 942 NDL PB coated UVS, PB ME/UB-250/42/1AH-E40-90/226 258 105 3.6/5 2.9 24500 100 942 NDL 4200 > 90 >8 <2 E40 90 226 – universal 12000 400 250 32 HCI-E 250/942 NDL PB 4008321908315 12 2 1
Luminous flux behaviour HCI-E
Survival rate HCI-E 100
50
HCI-E 250 W 830 WDL PB coated UVS, PB ME/UB-250/30/1BH-E40-90/226 245 95 3.6/5 2.9 24500 100 830 WDL 3000 91 > 50 < 0.1 E40 90 226 – universal 12000 400 250 32 HCI-E 250/830 WDL PB 4050300636825 12 2 1
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
11
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-E/P
1 HCI-E/P 35 W 830 WDL PB clear UVS, PB MCS/UB-35/30/1BH-E27-54/138 39 90 3.6/5 0.5 3000 77 830 WDL 3000 > 80 > 21 < 0.4 E27 54 138 86 universal 12000 330 190 6 HCI-E/P 35/830 WDL PB clear 4008321907837 12 1 1/2
New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-E/P 35 W 830 WDL PB coated UVS, PB MES/UB-35/30/1BH-E27-54/138 39 90 3.6/5 0.5 2850 73 830 WDL 3000 > 80 > 21 < 0.4 E27 54 138 – universal 12000 330 190 6 HCI-E/P 35/830 WDL PB coated 4008321907844 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
12
Downloaded from DatasheetLib.com - datasheet search engine
HCI-E/P 35 W 942 NDL PB coated UVS, PB MES/UB-35/42/1AH-E27-54/138 39 90 3.6/5 0.5 2850 73 942 NDL 4200 > 90 > 21 < 0.4 E27 54 138 – universal 12000 330 190 6 HCI-E/P 35/942 NDL PB coated 4008321907868 12 1 1/2
Luminous flux behaviour HCI-E/P
Survival rate HCI-E/P 100
50
HCI-E/P 35 W 942 NDL PB clear UVS, PB MCS/UB-35/42/1AH-E27-54/138 39 90 3.6/5 0.5 3000 77 942 NDL 4200 > 90 > 21 < 0.4 E27 54 138 86 universal 12000 330 190 6 HCI-E/P 35/942 NDL PB clear 4008321907851 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
POWERBALL® HCI®-E/P
1 HCI-E/P 70 W 830 WDL PB clear UVS, PB MCS/UB-70/30/1BH-E27-54/138 73 90 3.6/5 0.98 6500 89 830 WDL 3000 87 > 47 < 0.18 E27 54 138 86 universal 12000 330 190 12 HCI-E/P 70/830 WDL PB clear 4008321907875 12 1 1/2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-E/P 70 W 830 WDL PB coated UVS, PB MES/UB-70/30/1BH-E27-54/138 73 90 3.6/5 0.98 6400 88 830 WDL 3000 87 > 47 < 0.18 E27 54 138 – universal 12000 330 190 12 HCI-E/P 70/830 WDL PB coated 4008321907882 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
HCI-E/P 70 W 942 NDL PB coated UVS, PB MES/UB-70/42/1AH-E27-54/138 73 100 3.6/5 0.98 6000 82 942 NDL 4200 > 90 > 26 < 0.32 E27 54 138 – universal 12000 330 190 12 HCI-E/P 70/942 NDL PB coated 4008321907905 12 1 1/2
Luminous flux behaviour HCI-E/P
Survival rate HCI-E/P 100
50
HCI-E/P 70 W 942 NDL PB clear UVS, PB MCS/UB-70/42/1AH-E27-54/138 73 100 3.6/5 0.98 6100 84 942 NDL 4200 > 90 > 26 < 0.32 E27 54 138 86 universal 12000 330 190 12 HCI-E/P 70/942 NDL PB clear 4008321907899 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
13
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-E/P
1 HCI-E/P 100 W 830 WDL PB clear UVS, PB MCS/UB-100/30/1BH-E27-54/138 100 100 3.6/5 1.2 9000 90 830 WDL 3000 > 80 > 50 < 0.02 E27 54 138 86 universal 12000 330 190 16 HCI-E/P 100/830 WDL PB clear 4008321907912 12 1 1/2
New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-E/P 100 W 830 WDL PB coated UVS, PB MES/UB-100/30/1BH-E27-54/138 100 100 3.6/5 1.2 8500 85 830 WDL 3000 > 80 > 50 < 0.02 E27 54 138 – universal 12000 330 190 16 HCI-E/P 100/830 WDL PB coated 4008321907929 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
14
Downloaded from DatasheetLib.com - datasheet search engine
HCI-E/P 100 W 942 NDL PB coated UVS, PB MES/UB-100/42/1AH-E27-54/138 100 100 3.6/5 1.2 8300 83 942 NDL 4200 > 90 >8 <2 E27 54 138 – universal 12000 330 190 16 HCI-E/P 100/942 NDL PB coated 4008321907943 12 1 1/2
Luminous flux behaviour HCI-E/P
Survival rate HCI-E/P 100
50
HCI-E/P 100 W 942 NDL PB clear UVS, PB MCS/UB-100/42/1AH-E27-54/138 100 100 3.6/5 1.2 8800 88 942 NDL 4200 > 90 >8 <2 E27 54 138 86 universal 12000 330 190 16 HCI-E/P 100/942 NDL PB clear 4008321907936 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
POWERBALL® HCI®-E/P
1 HCI-E/P 150 W 830 WDL PB clear UVS, PB MCS/UB-150/30/1BH-E27-54/138 150 95 3.6/5 1.8 14000 93 830 WDL 3000 90 > 50 < 0.12 E27 54 138 86 universal 12000 330 190 20 HCI-E/P 150/830 WDL PB clear 4008321907950 12 1 1/2
Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Nominal luminous flux Luminous efficacy Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l LCL a Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A lm lm/W K Ra h mW/m2 · 1000 lx mm mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-E/P 150 W 830 WDL PB coated UVS, PB MES/UB-150/30/1BH-E27-54/138 150 95 3.6/5 1.8 13300 89 830 WDL 3000 90 > 50 < 0.12 E27 54 138 – universal 12000 330 190 20 HCI-E/P 150/830 WDL PB coated 4008321907967 12 1 1/2
90
90
Luminous flux in %
Survival rate in %
100
80 70 60 0
2000
HCI-E/P 150 W 942 NDL PB coated UVS, PB MES/UB-150/42/1AH-E27-54/138 150 91 3.6/5 1.8 13300 89 942 NDL 4200 > 95 > 50 < 0.17 E27 54 138 – universal 12000 330 190 20 HCI-E/P 150/942 NDL PB coated 4008321907981 12 1 1/2
Luminous flux behaviour HCI-E/P
Survival rate HCI-E/P 100
50
HCI-E/P 150 W 942 NDL PB clear UVS, PB MCS/UB-150/42/1AH-E27-54/138 150 91 3.6/5 1.8 14000 93 942 NDL 4200 > 95 > 50 < 0.17 E27 54 138 86 universal 12000 330 190 20 HCI-E/P 150/942 NDL PB clear 4008321907974 12 1 1/2
4000
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
15
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-R111
d
1 HCI-R111 20 W 830 WDL PB 10D UVS, PB MRS/UB-20/30/ 1B-H-GX8.5111/95/10 W 20 V 100 kVs 3.6/5 A 0.22 cd 17000 ° 10 830 WDL K 3000 Ra > 80 h >8 2 mW/m · 1000 lx < 2 GX8.5 mm 111 mm 95 universal h 12000 µF ECG HCI-R111 20/830 WDL PB 10D 4008321907998 Qty 6 No. 1 Fig. no. 2
New
Type ILCOS
Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life PF corr. cap. at 50 Hz Lamp reference
EAN Standard pack Figure Circuit (see page 26)
HCI-R111 20 W 830 WDL PB 24D UVS, PB MRS/UB-20/30/ 1B-H-GX8.5111/95/24 20 100 3.6/5 0.22 4200 24 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 ECG HCI-R111 20/830 WDL PB 24D 4008321908001 6 1 2
HCI-R111 20 W 830 WDL PB 40D UVS, PB MRS/UB-20/30/ 1B-H-GX8.5111/95/40 20 100 3.6/5 0.22 2000 40 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 ECG HCI-R111 20/830 WDL PB 40D 4008321908018 6 1 2
100
90
90
80 70 60 50
0
2000
16
Downloaded from DatasheetLib.com - datasheet search engine
4000
HCI-R111 35 W 830 WDL PB 24D UVS, PB MRS/UB-35/30/ 1B-H-GX8.5111/95/24 39 90 3.6/5 0.5 8500 24 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 6 HCI-R111 35/830 WDL PB 24D 4008321908032 6 1 1/2
HCI-R111 35 W 830 WDL PB 40D UVS, PB MRS/UB-35/30/ 1B-H-GX8.5111/95/40 39 90 3.6/5 0.5 4000 40 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 6 HCI-R111 35/830 WDL PB 40D 4008321908049 6 1 1/2
Luminous flux behaviour HCI-R111
100 Luminous flux in %
Survival rate in %
Survival rate HCI-R111
HCI-R111 35 W 830 WDL PB 10D UVS, PB MRS/UB-35/30/ 1B-H-GX8.5111/95/10 39 90 3.6/5 0.5 35000 10 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 6 HCI-R111 35/830 WDL PB 10D 4008321908025 6 1 1/2
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
POWERBALL® HCI®-R111
d
1 HCI-R111 35 W 942 NDL PB 10D UVS, PB MRS/UB-35/42/ 1A-H-GX8.5111/95/10 W 39 V 90 kVs 3.6/5 A 0.5 cd 35000 ° 10 942 NDL K 4200 Ra > 90 h >8 2 mW/m · 1000 lx < 2 GX8.5 mm 111 mm 95 universal h 12000 µF 6 HCI-R111 35/942 NDL PB 10D 4008321908056 Qty 6 No. 1 Fig. no. 1/2
New
Type ILCOS
Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life PF corr. cap. at 50 Hz Lamp reference
EAN Standard pack Figure Circuit (see page 26)
HCI-R111 35 W 942 NDL PB 24D UVS, PB MRS/UB-35/42/ 1A-H-GX8.5111/95/24 39 90 3.6/5 0.5 8500 24 942 NDL 4200 > 90 >8 <2 GX8.5 111 95 universal 12000 6 HCI-R111 35/942 NDL PB 24D 4008321908063 6 1 1/2
HCI-R111 35 W 942 NDL PB 40D UVS, PB MRS/UB-35/42/ 1A-H-GX8.5111/95/40 39 90 3.6/5 0.5 4000 40 942 NDL 4200 > 90 >8 <2 GX8.5 111 95 universal 12000 6 HCI-R111 35/942 NDL PB 40D 4008321908070 6 1 1/2
100
90
90
80 70 60 50
0
2000
4000
HCI-R111 70 W 830 WDL PB 24D UVS, PB MRS/UB-70/30/ 1B-H-GX8.5111/95/24 72 90 3.6/5 0.98 15000 24 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 12 HCI-R111 70/830 WDL PB 24D 4008321908094 6 1 1/2
HCI-R111 70 W 830 WDL PB 40D UVS, PB MRS/UB-70/30/ 1B-H-GX8.5111/95/40 72 90 3.6/5 0.98 9000 40 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 12 HCI-R111 70/830 WDL PB 40D 4008321908100 6 1 1/2
Luminous flux behaviour HCI-R111
100 Luminous flux in %
Survival rate in %
Survival rate HCI-R111
HCI-R111 70 W 830 WDL PB 10D UVS, PB MRS/UB-70/30/ 1B-H-GX8.5111/95/10 72 90 3.6/5 0.98 55000 10 830 WDL 3000 > 80 >8 <2 GX8.5 111 95 universal 12000 12 HCI-R111 70/830 WDL PB 10D 4008321908087 6 1 1/2
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
17
Downloaded from DatasheetLib.com - datasheet search engine
POWERBALL® HCI®-PAR 20, 30
1 HCI-PAR 20 35 W 830 WDL PB SP UVS, PB MRS/UB-35/30/1BH-E27-65/95/10 39 90 3.6/4.5 0.5 24000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 65 95 universal 12000 300 210 6 HCI-PAR 20 35/830 WDL PB SP 4008321908162 12 1 1/2
New Type ILCOS Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A cd ° K Ra h mW/m2 · 1000 lx mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-PAR 20 35 W 830 WDL PB FL UVS, PB MRS/UB-35/30/1BH-E27-65/95/30 39 90 3.6/4.5 0.5 5500 30 830 WDL 3000 > 80 > 22 < 0.37 E27 65 95 universal 12000 300 210 6 HCI-PAR 20 35/830 WDL PB FL 4008321908179 12 1 1/2
100
90
90
80 70 60 50
0
2000
18
Downloaded from DatasheetLib.com - datasheet search engine
4000
HCI-PAR 30 20 W 830 WDL PB FL UVS, PB MRS/UB-20/30/1BH-E27-97/125/30 20 90 3.6/4.5 0.22 4000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 ECG HCI-PAR 30 20/830 WDL PB FL 4008321908155 6 1 2
Luminous flux behaviour HCI-PAR
100 Luminous flux in %
Survival rate in %
Survival rate HCI-PAR
HCI-PAR 30 20 W 830 WDL PB SP UVS, PB MRS/UB-20/30/1BH-E27-97/125/10 20 90 3.6/4.5 0.22 24000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 ECG HCI-PAR 30 20/830 WDL PB SP 4008321908148 6 1 2
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
POWERBALL® HCI®-PAR 30
1 HCI-PAR 30 35 W 830 WDL PB SP UVS, PB MRS/UB-35/30/ 1B-H-E2797/125/10 39 90 3.6/4.5 0.5 46000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 6 HCI-PAR 30 35/830 WDL PB SP 4008321908209 6 1 1/2
New Type ILCOS
Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference
W V kVs A cd ° K Ra h mW/m2 · 1000 lx mm mm h °C °C µF
EAN Standard pack Figure Circuit (see page 26)
Qty No. Fig. no.
HCI-PAR 30 35 W 830 WDL PB FL UVS, PB MRS/UB-35/30/ 1B-H-E2797/125/30 39 90 3.6/4.5 0.5 8500 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 6 HCI-PAR 30 35/830 WDL PB FL 4008321908216 6 1 1/2
100
90
90
80 70 60 50
0
2000
4000
HCI-PAR 30 70 W 830 WDL PB FL UVS, PB MRS/UB-70/30/ 1B-H-E2797/125/30 73 90 3.6/4.5 0.98 14000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 12 HCI-PAR 30 70/830 WDL PB FL 4008321908254 6 1 1/2
HCI-PAR 30 70 W 830 WDL PB 40D UVS, PB MRS/UB-70/30/ 1B-H-E2797/125/40 73 90 3.6/4.5 0.98 12000 40 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 12 HCI-PAR 30 70/830 WDL PB 40 D 4008321908261 6 1 1/2
Luminous flux behaviour HCI-PAR
100 Luminous flux in %
Survival rate in %
Survival rate HCI-PAR
HCI-PAR 30 70 W 830 WDL PB SP UVS, PB MRS/UB-70/30/ 1B-H-E2797/125/10 73 90 3.6/4.5 0.98 70000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 12000 300 210 12 HCI-PAR 30 70/830 WDL PB SP 4008321908247 6 1 1/2
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
19
Downloaded from DatasheetLib.com - datasheet search engine
POWERSTAR® HCI®-PAR 20, 30
1 HCI-PAR 20 35 W 830 WDL SP Spot 10°, UVS MRS/UB-35/30/ 1B-H-E27-65/ 95/10 W 38 V 90 kVs 3.6/4.5 A 0.5 cd 22000 ° 10 830 WDL K 3000 Ra > 80 h > 22 2 mW/m · 1000 lx < 0.37 E27 mm 65 mm 95 universal h 9000 °C 300 °C 210 µF 6 HCI-PAR 20 35/830 WDL SP 4050300941936 Qty 12 No. 1 Fig. no. 1/2
Type ILCOS
Lamp wattage Lamp voltage Ignition voltage min./max. Lamp current Axial luminous intensity Beam angle Light colour/Colour appearance Colour temperature Colour rendering index NIOSH Skin ACGIH UV output Base Diameter d Length max. l Burning position Average lamp life Max. perm. outer bulb temp. Max. perm. base edge temp. PF corr. cap. at 50 Hz Lamp reference EAN Standard pack Figure Circuit (see page 26)
HCI-PAR 20 35 W 830 WDL FL Flood 30°, UVS MRS/UB-35/30/ 1B-H-E27-65/ 95/30 38 90 3.6/4.5 0.5 5000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 65 95 universal 9000 300 210 6 HCI-PAR 20 35/830 WDL FL 4050300941950 12 1 1/2
HCI-PAR 30 35 W 830 WDL SP Spot 10°, UVS MRS/UB-35/30/ 1B-H-E27-97/ 125/10 38 90 3.6/4.5 0.5 37000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 6 HCI-PAR 30 35/830 WDL SP 4050300941974 6 1 1/2
100
90
90
80 70 60 50
0
2000
20
Downloaded from DatasheetLib.com - datasheet search engine
4000
HCI-PAR 30 70 W 830 WDL SP Spot 10°, UVS MRS/UB-70/30/ 1B-H-E27-97/ 125/10 73 90 3.6/4.5 0.97 55000 10 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 12 HCI-PAR 30 70/830 WDL SP 4050300942018 6 1 1/2
HCI-PAR 30 70 W 830 WDL FL Flood 30°, UVS MRS/UB-70/30/ 1B-H-E27-97/ 125/30 73 90 3.6/4.5 0.97 10000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 12 HCI-PAR 30 70/830 WDL FL 4050300942032 6 1 1/2
Luminous flux behaviour HCI-PAR
100 Luminous flux in %
Survival rate in %
Survival rate HCI-PAR
HCI-PAR 30 35 W 830 WDL FL Flood 30°, UVS MRS/UB-35/30/ 1B-H-E27-97/ 125/30 38 90 3.6/4.5 0.5 7000 30 830 WDL 3000 > 80 > 22 < 0.37 E27 97 125 universal 9000 300 210 6 HCI-PAR 30 35/830 WDL FL 4050300941998 6 1 1/2
6000 Hours burned
8000
10000
12000
80 70 60 50
0
2000
4000
6000 Hours burned
8000
10000
12000
Please note: The values and curves published in this document are for guidance only. The basic data was determined under controlled laboratory conditions for a switching cycle of 11 h on/1 h off. There may be considerable differences in actual practice. The highlighted areas around the curves represent a 90% confidence range based on our test conditions.
NIOSH threshold and ACGIH UV output: The radiated energy of a lamp is indicated by the defined NIOSH curve. The NIOSH effective radiated output calculated from this is converted into permitted exposure times with defined limit values. The ACGIH UV output value correlates directly with the NIOSH value and represents the current required value for UV exposure.
PF correction capacitor: The pf correction capacitors are designed so that cos ≥ 0.9 is achieved at rated voltage.
21
Downloaded from DatasheetLib.com - datasheet search engine
Operating instructions Supply voltage: The lamps must be connected via suitable control gear. A 240 V / 50 Hz ac supply is generally required. If a different supply voltage is used (e.g. 400 V / 50 Hz) control gear with appropriate taps must be used.
Operating temperatures: Only high-pressure discharge lamps with external igniters are suitable for low-temperature applications down to – 50 °C. Such applications call for special (heatable) igniters such as MZN 400 SU-LT from BAG Turgi (for lamps from 100 to 400 W).
Permitted mains voltage deviation: ± 3% Sudden fluctuations in mains voltage of more than 10% may cause the lamps to go out. If the deviation from rated supply voltage (230 V or 400 V) is permanent, high-pressure discharge lamps may exhibit changes in colour or luminous flux. Lamp life may also be reduced.
Power factor: CCG: Because of the series connected choke this is around 0.5 to 0.7 (without compensation) ECG: If POWERTRONIC® is used the power factor is greater than 0.96. Compensation is therefore not needed here.
Control gear: Switching on: Conventional control gear: Choke, igniter and pf correction capacitor. The right igniter for the particular lamp type must be used to ensure reliable and safe ignition. Igniters must always be installed close to the lamp. The choke may be installed any distance from the lamp, provided the permissible voltage drop is not exceeded. For power supplies with a neutral conductor the choke should be connected to the live conductor. In the case of luminaires in which there are no lamps installed, the ignition equipment (igniter, ignition pulser) must be disabled when voltage is applied otherwise the igniters may produce radio interference. The chokes and pf correction capacitors generally needed for operating discharge lamps may, under certain conditions, create oscillating circuits. These circuits may then produce excessive currents and voltages, which in turn can destroy the lamps, ballasts and capacitors. Such resonance phenomena must be avoided by appropriate circuits and fuses. When high-pressure discharge lamps come to the end of their lives a rectifier effect may occur (see IEC 62035). This is not manufacturer-specific. Because of the excessive dc current components the ballasts and igniters may become overheated. High-pressure discharge lamps should therefore only be operated with control gear with thermal protection. This applies also to control gear with the option of power reduction. Suitable igniters and control gear for POWERBALL® HCI® are available from the electrical industry.
22
Downloaded from DatasheetLib.com - datasheet search engine
Full luminous flux is reached only a few minutes after the lamp is switched on. The start-up current may be up to twice the operating current depending on the control gear. (See also the graphs on p. 25)
Fusing: HCI® lamps must be protected by slow acting fuses. If fuse wire is used it is sufficient for it to be rated at twice the rated current of the lamp. If automatic cutouts are used they should have characteristic “C”. If adjusted to the upper limit value of 10 x rated current there will be no triggering if fuse protection is at twice the rated lamp current.
Restarting: The lamps will restart only after they have cooled down for 2 to 15 minutes.
Lampholders: Because of the high voltages involved in ignition the lampholders must be designed for these high voltages. Lampholders that meet these requirements are available from appropriate manufacturers.
Dimming: In principle, dimming of HCI® POWERBALL® is technically feasible, but OSRAM does not recommend it for the lamps currently available on the market, because the typical characteristics of HCI® POWERBALL® change when dimmed. The higher thermal load capacity of the round ceramic burner offers better dimming behavior in terms of luminous efficacy and color rendering compared to metal halide lamps with quartz burners or standard cylindrical ceramic burners. As before, however, dimming does lead to a change in the chromaticity coordinates. Lamps operated at dimmed settings suffer a greater loss of luminous flux and a greater color shift over their lifetime.
Because there are many different methods of dimming and the effects on the physics of the lamps are highly complex there is as yet no statistically sound information on the performance of the lamps over their lifetime. In addition, there is still no standardized dimming cycle by which the lamps can be reliably tested. The warranted product characteristics cannot therefore be guaranteed for lamps operated at dimmed settings. The operation of OSRAM HCI® POWERBALL® lamps at dimmed settings is not permitted as this results in significant color shifts, bad lumen maintenance and shorter lifetime.
As we cannot completely rule out the possibility of the bulb bursting, luminaires for the lamps mentioned above must be equipped with sealed shatter-proof shields that can withstand wide fluctuations in temperature. Operating lamps with a damaged outer bulb is dangerous and therefore not permitted.
Lamp operation: Operating high-pressure lamps for short periods in combination with frequent on/off switching will shorten their life. This applies to both cold starting and hot restarts.
End of life: To protect the control gear and to avoid radio interference, high-pressure discharge lamps must be replaced as soon as they come to the end of their life. These lamps reach their end of life when ● the light colour of the lamp changes dramatically ● there is a significant loss of brightness ● the lamp no longer ignites ● the lamp starts to cycle (periodically goes out and ignites again). As a lamp reaches the end of its life the risk of bursting increases. This phenomenon is caused by effects not connected with the manufacturer, such as the rectifying effect mentioned earlier. Because of this we strongly recommend changing the lamp no later than when it reaches its average life or if one of the above effects occurs.
The following lamps are suitable for open luminaires: ● All HCI®-T/P ● All HCI®-E/P ● All HCI®-R111 ● All HCI®-PAR The use of shields should be considered for safety reasons in each case. HCI® lamps for outdoor applications and damp locations may only be operated in luminaires approved for the purpose.
Luminaire design: Luminaire design (thermal design and fuse protection) should be based on the EN 60598-1 standard.
Photometric and electrical data: Notes on disposal: All metal halide lamps contain small quantities of mercury. If they break, poisonous mercury vapour may be released. The lamps must be treated as waste requiring special supervision with EEC code 20 01 21 for waste or residue containing mercury and should be passed to a relevant collection or recycling company.
Guarantee: A guarantee can only made if suitable control gear is used and the defined operating conditions are met.
Safety: OSRAM high-pressure lamps meet the safety requirements defined in IEC 62035. All HCI® lamps are of UV-reduced design. Because of their high operating pressure the following lamps may only be used in fully enclosed luminaires designed to take them: ● All HCI®-TS ● All HCI®-T, all HCI®-TT ● All HCI®-TC ● All HCI®-E ≥ 250 W ● All HCI®-TF ● All HCI®-TM
All lamp-specific electrical and photometric data is measured after 100 hours of operation under laboratory conditions on reference equipment. The measurement switching cycle is 11 hours on/ 1 hour off. Unless otherwise indicated, the data relates to the horizontal burning position for TS types and to the base up burning position for other types. The graphs for survival rates and luminous flux behaviour are average values for all wattages and light colours of lamps identical in construction. The spread of the average values has not been taken into account. For detailed information on particular lamp types please contact OSRAM. The luminous flux is virtually unaffected by the ambient temperature outside the luminaire. At low ambient temperatures down to around – 50 C° special igniters are needed. Detailed information on heat accumulation tubes (luminaire simulators) for determining lamp data for HCI®-TS is given in IEC 61167, clause 1.7. Colour deviations: With all metal halide lamps there may be differences in colour from one lamp to the next due to external factors such as mains voltage, type of control gear used, burning position and luminaire design.
23
Downloaded from DatasheetLib.com - datasheet search engine
Lamp life There are a confusing number of definitions for lamp life, and these differ from one region to the next and from one application to the next. The basic definitions for the most common types are given below.
Minimum life: Minimum period of time in which a lamp remains in operation under laboratory conditions.
This document refers explicitly only to the average life. Economical life: Average life: Average number of hours burned over several groups in which in the group in question half the lamps have failed as the result of a defect (corresponds to 50% failure).
Service life:
Survival rate: Quantity of working lamps of a group of lamps after a defined number of burning hours. Average value of some groups.
Operating characteristics in relation to the supply voltage POWERBALL ≤ 250 W 130 % 120 110 100
PL
UL IL
90
Φ 80 70 90
95
Period of time between group relamping of an installation under the condition that operating costs are minimised and the installation luminous flux does not fall below a particular value. This will vary according to the application.
100
105 % 110
Mains voltage
Φ = Luminous flux
PL = Lamp wattage
IL = Lamp current
UL = Lamp voltage
= Not permitted
24
Downloaded from DatasheetLib.com - datasheet search engine
Simplified practical view of the economical life. This is the operating time after which the installation luminous flux (the product of the relative luminous flux and the lamps still in operation) is still around 70% (sometimes 80%).
Start-up behaviour (average value)
180
180
160
160
140
140
120
120
100
100
Rel. operating values %
POWERBALL HCI-T ≤ 250 W with CCG
Rel. operating values %
POWERBALL HCI-T ≤ 250 W with PTU
80 60 40 20 0
1
2 3 min 4 Start-up time
80 60 40 20 0
1
2 3 min 4 Start-up time
25
Downloaded from DatasheetLib.com - datasheet search engine
Circuit diagrams
L POWERTRONIC PTi (all)
N
LH
LP LL
1
2
D = Choke K = PF correction capacitor LP = Lamp UN = 230 V ac mains voltage (for 2000 W = 400 V ac)
Z = Igniter to be installed near the lamp ZL = HF igniter lead to contact plate of lamp
For power supplies with a neutral conductor the choke should be connected to the live conductor. The right igniter for the particular lamp type must be used to ensure reliable and safe ignition. Chokes, holder, capacitors and igniters are available from electrical suppliers.
Burning positions
ϒ
s5
Permitted
Not permitted
Base
8.5
6.5 6,5 8.5 8,5 G22 IEC 7004-75
26
Downloaded from DatasheetLib.com - datasheet search engine
G 8.5
GX 8.5
G12 GU6.5
Spectral power distribution of discharge lamps POWERBALL®
HCI® . . ./WDL
HCI® .../NDL
Visible range from 380 to 780 nm Vertical scale
400 mW 1000 lm · 10 nm
POWERBALL® SHOPLIGHT
Visible range from 380 to 780 nm Intensity per 10 nm
●
All rights reserved. No part of this document may be reproduced, copied or distributed in any form (printed matter, photocopy, etc.) without the written permission of HID M-M, OSRAM Germany.
●
This brochure supersedes all previous editions.
●
All dimensions, weights, specifications and graphic representations are given without obligation. All design features, dimensions and technical specifications are subject to change without notice.
27
Downloaded from DatasheetLib.com - datasheet search engine
Global presence. OSRAM supplies customers in around 150 countries. • 65 companies and sales offices for 100 countries • 48 countries served by local agents or OSRAM GmbH, Munich
OSRAM GmbH Head Office Hellabrunner Strasse 1 81543 Munich Germany Tel.: +49-(0)89-6213-0 Fax: +49-(0)89-6213-2020 www.osram.com
Downloaded from DatasheetLib.com - datasheet search engine
Kazakhstan Kenya Latvia Lithuania Malaysia Mexico Norway Philippines Poland Portugal Rumania Russia Serbia-Montenegro Singapore Slovakia South Africa South Korea Spain Sweden Switzerland Taiwan Thailand Turkey Ukraine United Arab Emirates USA Vietnam
104 T001 GB 12/06 CO OSRAM HID Subject to modification without notice. Errors and omissions excepted
Argentina Australia Austria Benelux Bosnia-Herzegovina Brazil Bulgaria Canada Chile China Columbia Croatia Czech Republic Denmark Ecuador Egypt Estonia Finland France Germany Great Britain Greece Hungary India Indonesia Iran Italy Japan
z Printed on paper treated with chlorine-free bleach
OSRAM associated companies and support centres.