Product Datasheet P/N 46077 - Rev. 3A Page 1 of 2 Date 01-04-2000
Belden 1583E Cat 5 enhanced UTP PVC
Application • •
Horizontal and building backbone cable. Support current and future Category 5 enhanced applications, such as: 10 Base-T, 100 Base-T, 1000 Base-T (Gibabit Ethernet), FDDI, ATM
Standards General standards: ISO/IEC 11801, EN 50173, TSB 36, TIA/EIA 568-A-5 (enhanced) Future standards like: JTC1 SC25 WG3 N568 and prEN 50288-3-1
Construction & Dimensions • • • • • • •
Construction: Conductor: Conductor diameter: Conductor insulation material: Diameter over insulation: Jacket material: Outer diameter:
Unshielded 4 twisted pairs solid bare copper AWG 24 (0,51 mm) Polyethylene (PE) 0,90 mm ± 0.05 mm Flame retardant PVC 4,70 mm ± 0.30 mm
Colour code Pair 1 Pair 2 Pair 3 Pair 4
White-Blue/Blue White-Orange/Orange White-Green/Green White-Brown/Brown
Electrical characteristics (at 20 ºC) Attenuation Frequency Spec. (Max.)1) Typical
1 2.1 2.0
4 4.3 4.0
10 6.6 6.3
16 8.2 8.0
20 9.2 9.0
31.25 11.8 11.3
62.5 17.1 16.2
100 22.0 20.7
MHz dB/100m dB/100m
4 56.3 64
10 50.3 58
16 47.3 55
20 45.8 54
31.25 42.9 51
62.5 38.4 47
100 35.3 44
MHz dB dB
4 53.3 62
10 47.3 56
16 44.3 53
20 42.8 52
31.25 39.9 49
62.5 35.4 45
100 32.3 42
MHz dB/100m dB/100m
1 60.8 71
4 48.7 59
10 40.8 51
16 36.7 46
20 34.7 43
31.25 30.9 39
62.5 24.8 33
100 20.8 28
MHz dB/100m dB/100m
1 63 71
4 52 61
10 44 52
16 39 48
20 37 45
31.25 31 40
62.5 22 31
100 14 24
MHz dB/100m dB/100m
4 49 59
10 41 50
16 36 46
20 34 43
31.25 28 38
62.5 19 29
100 11 22
MHz dB/100m dB/100m
NEXT (Near end crosstalk) Frequency Spec. (Min.)1) Typical
1 65.3 73
Power sum NEXT Frequency Spec. (Min.)1) Typical
1 62.3 71
Power sum ELFEXT Frequency Spec. (Min.)2) Typical
ACR Frequency Spec. (Min.)1) Typical
Power sum ACR Frequency Spec. (Min.)1) Typical 1) 2)
1 60 69
: Specification values according to cable requirements of ISO/IEC 11801 category 5 enhanced : Specification values according to cable requirements of ANSI/TIA/EIA-568-A-5 (enhanced) Belden Wire & Cable B.V. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner
Product Datasheet P/N 46077 - Rev. 3A Page 2 of 2 Date 01-04-2000
Belden 1583E Cat 5 enhanced UTP PVC
Electrical characteristics (at 20 ºC) Nominal mutual capacitance at 1 kHz Maximum conductor DCR NVP - Nominal Velocity of Propagation SKEW – Propagation delay difference (100 MHz) Impedance 1-100 MHz
50 nF/km 93.5 Ohm/km 0.68 c typical ≤ 10 ns/100m 100 ± 15 Ohm
General and environmental characteristics Temperature range - operation Temperature range - installation Minimum bending radius - operation Minimum bending radius - installation Maximum pulling tension Flame retardancy Energy of flame Weight (approx.) Maximum operating voltage Maximum continuous current per conductor (25°C)
-20°C - +60°C +0°C - +50°C 19 mm 38 mm 80 N IEC 332-1 410 kJ/m 28 kg/km 48 V rms 1.4 A
Ordering information MARKING Text on the cable jacket
Inkjet printing
BELDEN 1583E UTP CAT5E 4PR AWG24 ISO/IEC 11801 EN50173 EC VERIFIED 100 OHM Meter marking: Production date marking: JACKET COLOUR Colour Grey Blue
Yes Yes RAL code RAL 7032 RAL 5015
PACKAGING (PUT UP) Belden code Delivery length 46077 xxxx 172 100 m 46077 xxxx 178 305 m 46077 xxxx 028 305 m 46077 xxxx 011 500 m 46077 xxxx 240 1000 m xxxx: Belden colour code
Belden colour code 2830 2873
Weight 2,8 kg 8,5 kg 8,5 kg 14,0 kg 28,0 kg
Remark Carton box Unreel box Non returnable reel Non returnable reel Non returnable reel
Belden Wire & Cable B.V. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner