Preview only show first 10 pages with watermark. For full document please download

Db 12-120 12v120ah

   EMBED


Share

Transcript

DB 12-120 12V120AH Duration Series SLA Battery DB Series DB (Duration) Series batteries utilizes thick grids of modern technology are adopted so as to guarantee the design life up to 12 years. Advanced micro porous absorbed glass matt separator - minimizes diffusion of oxygen into the separator, reducing float charge current which suppressed the corrosion rate of the positive grid and extends the life of the battery. Application · Cable Television · Communication Equipment · Security System · UPS · Control Equipment · Medical Equipment · Emergency Power System · Power Plant General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94HB, UL94V-0) optional. · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexibility design for multiple install positions. Construction 3mm (0.12inch) · Sealant ........Epoxy Resin · Safety valve .....EPDR · Terminal ........Pb Alloy · Separator ........Fiber glass · Electrolyte ........Sulfuric acid M8mm (0.31inch) Terminal Dimensions 233mm(9.17inch) · Component ......Raw material · Positive ........Lead dioxide · Negative ........Lead · Container ........ABS ........ABS · Cover 16mm (0.63inch) 174mm(6.85inch) 406mm(16.0inch) Battery Model DB12-120 Designed Floating Life Capacity(20oC) 12 Years 20HR(6.35A,1.80V) 10HR(12A,1.80V) 127AH Dimensions 103AH 75.2AH Length Width Height Total Height 406mm(16.0inch) 174mm(6.85inch) 208mm(8.19inch) 233mm(9.17inch) 35Kg (77.2 lbs) o Full charged at 20 C: 0.004 Ohm Internal Resistance < 3% of capacity declined per month at (20oC) Self Discharge Charge Voltage(20oC) 1HR(75.2A,1.60V) 120AH Approx. Weight Capacity Affected by Temp.(20HR) 5HR(20.5A,1.75V) 40oC 102% 20oC 0oC 100% 85% Cycle use o 14.4-14.8V(-30mV/ C), max. Current: 30A Page 1 of 2 -15oC 65% Float use 13.6-13.8V(-20mV/ oC) DB 12-120 12V120AH Charge Voltage (CA) (V/Cell) (%) 120 2.33 100 80 0.25 Constant Charge At 0.25CA-2.30V (20 C) Charge Capacity Charge Voltage 2.17 100%Discharge 2.00 50%Discharge 0.15 40 0.10 20 1.83 0.05 0 0 Discharge Characteristic (20 C) o 0.20 60 o Charge Characteristic Charge Current 0 2 4 6 8 10 Discharge Voltage (V/Cell) Charge Current Charge Capacity Duration Series SLA Battery 2.17 2.00 1.83 0.25CA 1.67 3CA 1.50 0 12 2 6 1CA 0.6CA 12 30 60 3 Min Time(hour) 10 Hour 20 Self Discharge Characteristics Relationship of OCV and state of charge 110 105 2.25 2.17 Capacity (%) Battery Voltage (V/Cell) 2CA 0.1CA 0.05CA 2.08 2.00 100 95 90 85 80 75 70 65 60 55 50 1.92 40oC 45 1.83 0 10 20 30 40 50 60 70 80 90 100 40 0 1 2 o 20 C o 30 C 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Storage time: months Remained Capacity(%) Constant current discharge ratings-amperes at 20oC F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR 1.60V 420 288 210 126 75.2 32.8 20.8 12.7 6.64 1.67V 378 263 204 122 75.1 32.6 20.7 12.5 6.62 1.70V 359 253 197 120 74.9 32.6 20.7 12.4 6.62 1.75V 319 234 186 118 74.1 32.4 20.5 12.2 6.59 1.80V 288 217 178 114 73.2 32.3 20.3 12.0 6.35 1.85V 218 179 154 105 72.4 32.2 20.2 11.8 5.97 o Constant power discharge ratings-watts at 20 C F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 3HR 5HR 10HR 20HR 1.60V 692 478 372 238 148 62.9 39.9 25.5 13.3 1.67V 656 472 368 233 143 62.9 39.9 25.1 13.2 1.70V 613 460 362 227 140 62.9 39.9 24.9 13.2 1.75V 571 430 341 221 138 61.9 39.4 24.4 13.2 1.80V 512 400 320 215 136 61.1 38.8 24.0 12.7 1.85V 410 331 280 197 135 60.8 38.2 23.6 11.9 ISO9001 COPYRIGHT BSB POWER COMPANY LIMITED Page 2 of 2