Transcript
DB 12-120
12V120AH
Duration Series SLA Battery DB Series DB (Duration) Series batteries utilizes thick grids of modern technology are adopted so as to guarantee the design life up to 12 years. Advanced micro porous absorbed glass matt separator - minimizes diffusion of oxygen into the separator, reducing float charge current which suppressed the corrosion rate of the positive grid and extends the life of the battery.
Application · Cable Television · Communication Equipment · Security System · UPS
· Control Equipment · Medical Equipment · Emergency Power System · Power Plant
General Features · Sealed and maintenance free operation. · Non-Spillable construction design. · ABS containers and covers(UL94HB, UL94V-0) optional. · Safety valve installation for explosion proof. · High quality and high reliability. · Exceptional deep discharge recovery performance. · Low self discharge characteristic. · Flexibility design for multiple install positions.
Construction
3mm (0.12inch)
· Sealant ........Epoxy Resin · Safety valve .....EPDR · Terminal ........Pb Alloy · Separator ........Fiber glass · Electrolyte ........Sulfuric acid
M8mm (0.31inch)
Terminal Dimensions
233mm(9.17inch)
· Component ......Raw material · Positive ........Lead dioxide · Negative ........Lead · Container ........ABS ........ABS · Cover
16mm (0.63inch)
174mm(6.85inch)
406mm(16.0inch)
Battery Model
DB12-120
Designed Floating Life Capacity(20oC)
12 Years 20HR(6.35A,1.80V)
10HR(12A,1.80V)
127AH Dimensions
103AH
75.2AH
Length
Width
Height
Total Height
406mm(16.0inch)
174mm(6.85inch)
208mm(8.19inch)
233mm(9.17inch)
35Kg (77.2 lbs) o
Full charged at 20 C: 0.004 Ohm
Internal Resistance
< 3% of capacity declined per month at (20oC)
Self Discharge
Charge Voltage(20oC)
1HR(75.2A,1.60V)
120AH
Approx. Weight
Capacity Affected by Temp.(20HR)
5HR(20.5A,1.75V)
40oC 102%
20oC
0oC
100%
85%
Cycle use o
14.4-14.8V(-30mV/ C), max. Current: 30A
Page 1 of 2
-15oC 65% Float use 13.6-13.8V(-20mV/ oC)
DB 12-120
12V120AH
Charge Voltage
(CA) (V/Cell)
(%) 120
2.33
100 80
0.25
Constant Charge At 0.25CA-2.30V (20 C) Charge Capacity
Charge Voltage
2.17 100%Discharge 2.00
50%Discharge
0.15
40
0.10 20
1.83
0.05
0
0
Discharge Characteristic (20 C)
o
0.20
60
o
Charge Characteristic
Charge Current 0
2
4
6
8
10
Discharge Voltage (V/Cell)
Charge
Current
Charge Capacity
Duration Series SLA Battery
2.17 2.00 1.83 0.25CA
1.67 3CA
1.50
0
12
2
6
1CA
0.6CA
12
30
60
3
Min
Time(hour)
10 Hour
20
Self Discharge Characteristics
Relationship of OCV and state of charge 110 105
2.25
2.17
Capacity (%)
Battery Voltage (V/Cell)
2CA
0.1CA 0.05CA
2.08
2.00
100 95 90 85 80 75 70 65 60 55 50
1.92
40oC
45
1.83
0
10
20
30
40
50
60
70
80
90
100
40
0
1
2
o
20 C
o
30 C 3
4
5
6
7 8
9 10 11 12 13 14 15 16 17 18 19 20
Storage time: months
Remained Capacity(%)
Constant current discharge ratings-amperes at 20oC F.V/Time
5MIN
10MIN
15MIN
30MIN
1HR
3HR
5HR
10HR
20HR
1.60V
420
288
210
126
75.2
32.8
20.8
12.7
6.64
1.67V
378
263
204
122
75.1
32.6
20.7
12.5
6.62
1.70V
359
253
197
120
74.9
32.6
20.7
12.4
6.62
1.75V
319
234
186
118
74.1
32.4
20.5
12.2
6.59
1.80V
288
217
178
114
73.2
32.3
20.3
12.0
6.35
1.85V
218
179
154
105
72.4
32.2
20.2
11.8
5.97
o
Constant power discharge ratings-watts at 20 C F.V/Time
5MIN
10MIN
15MIN
30MIN
1HR
3HR
5HR
10HR
20HR
1.60V
692
478
372
238
148
62.9
39.9
25.5
13.3
1.67V
656
472
368
233
143
62.9
39.9
25.1
13.2
1.70V
613
460
362
227
140
62.9
39.9
24.9
13.2
1.75V
571
430
341
221
138
61.9
39.4
24.4
13.2
1.80V
512
400
320
215
136
61.1
38.8
24.0
12.7
1.85V
410
331
280
197
135
60.8
38.2
23.6
11.9
ISO9001