DC axial fans Automotive series W3G300, Ø 300mm Speed (1) Current draw (1) Temperature range (1) Mass VDC VDC Watts RPM A °C lbs W3G300-BV25-21 M3G084-BF 1897 26 16...32 380 3940 14.6 -40...85/110C 4.4 Ingress protection rating (electronics) Power input (1) CFM Ingress protection rating (motor) Voltage range Type Direction of air flow (intake) Voltage Motor Nominal Data Sealed ball bearings Air flow Highlights: – Control input: 0-10 VDC/PWM – Load dump (58V) – Over-voltage detection – Over-temperature protected electronics – Soft start, motor current limit, line undervoltage detection – Over 85C with power derating – Reverse polarity and locked rotor protection Material: Impeller: PA plastic Electronic housing: PA plastic Mounting position: Any Condensate discharge holes: None, open rotor Direction of rotation: Clockwise, seen on rotor IP 24 KM IP 6K 9K rotor Yes V (1) Nominal data at free air. [in. wg] Curves Pe I LpAin LwAin rpm W A dB(A) dB(A) 2.80 Measurement: LU-141116 A 1 3940 380 14.6 79 87 A 2 3815 408 15.7 79 87 2.40 Air performance measured as per: ISO 5801, Installation category A, without protection against accidental contact. A 3 3715 462 17.7 78 85 A 4 3630 495 19.0 81 88 Suction-side noise levels: LWA as per ISO 13347, LPA measured at 1m distance to fan axis. A 5 A 6 A 7 The values given are valid under the measuring conditions mentioned and may vary accoring to the actual installation situation. A 8 2.00 4 1.60 3 1.20 With any deviation to the standard set-up, the specific values have to be checked and reviewed once installed or fitted. 0.80 2 0.40 ΔP n 0.00 0 200 400 600 800 1000 1200 1400 1600 1800 1 2000 [cfm] For detailed information on the measuring set-up, please contact ebm-papst. A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 W3G300-BV25-21 Dimensions shown in millimeters GND (brown) PWM/LIN (yellow) GND (brown) PWM/LIN (yellow) + UB (black) + UB (black) Diagnostic output (white) Diagnostic output (white) INVLIN (orange) ABSENK (blue) INVLIN (orange) ABSENK (blue) Connection line with plug Tyco Junior Power Timer 1-962349-1, 6-pole, coded Connection line with plug Tyco Junior Connection line (460Timer mm) 1-962349-1, with mating 6-pole, coded Power connector partConnection no. 02002-4-1021 not with mating line (460 mm) included in scope of delivery connector part no. 02002-4-1021 not included in scope of delivery Direction of air flow "V" Direction of air flow "V" Connection screen No. Conn. Designation Function / assignment 1 UB +26 VDC Power supply 26 VDC 2 GND Power supply GND, reference ground 3 PWMLIN Analogue voltage control input 0 -10 V or PWM 4 INVLIN Control input, inverse linear 5 ABSENK Lowering input 6 DU Diagnostic output