Preview only show first 10 pages with watermark. For full document please download

Dc Blanket Warming Cabinets

   EMBED


Share

Transcript

Designer Series Blanket Warming Cabinet • Energy-efficient WarmSafe™ heating system monitors interior surface temperatures and balances heat throughout the cabinet (Patent No: US 8,217,316; US 8,581,152) DC250 DC150 (shown with optional timer) • Silent operation (no fans or moving parts) • Lint traps not required DC350 • Stationary or mobile option • Epoxy-coated exterior & interior surfaces • Programmable control • Interior lighting with a comforting blue glow. Two (2) intensity settings • Five capacities available: »» 3-4 blankets (1.5ft3) »» 4-6 blankets (2.5ft3) »» 10-12 blankets (3.5ft3) »» 14-18 blankets (4.0ft3) DC750 (shown with optional timer) »» 20-25 blankets (7.5ft3) DC400 (shown with optional timer) www.enthermics.com Designer Series Blanket Warming Cabinet • • • • • • • • Additional features: control: specifications: Single-chamber warming cabinet. White epoxy-coated steel exterior casing and interior insert. Single pane, energy-efficient, e-coated glass window in door allows for inventory observation. Easy push-button door for hands-free operation. Door is fully gasketed and hinged on the right side of the unit. WarmSafe™ incorporates a multiple zone warming technology (Patent No: US 8,217,316; US 8,581,152) that heats where and when it is needed. All chamber surface temperatures are monitored, providing an efficient balance of heat, low-energy consumption and minimal heat loss. • • • • • • • • • DC350 & DC750 include a heated center shelf to further optimize heat distribution throughout the cavity. Four (4) non-skid rubber feet are standard. Adjustable temperature range of 32° - 71°C (90° - 160°F) Operates in Celsius or Fahrenheit. Four digit L.E.D. display. • • On/off button. Up and down adjustment buttons. • Actual temperature button. Interior light button. Built-in speaker for audible feedback. Integrated control lockout feature. • • clearance requirements: L.E.D. interior lighting casts a comforting blue glow with two (2) different intensity settings and off mode. Safety: In the event of a power failure the cabinet will retain its programming and operates as previously set when power is restored. Safety: A warming shut-off system, separate from the electronic control, prevents overheating. Convenience: Access point and removable cover has been added to the back panel that allows the addition of data logging or temperature management hardware. Convenience: Stackable configurations are available for additional capacity or to pair with fluid warmers. 3" (76mm) from rear 1" (25mm) from top and sides 3/4" (19mm) from bottom Options & Accessories – specify at time of order Door Assembly: Caster Assemblies: Bumper & Caster Assembly, 3" (76mm); overall height increases by 5" (127mm) DC250 or DC350 White epoxy coated – 5017546 Stainless Steel – 5017548 DC400 or DC750 White epoxy coated – 5017547 Stainless Steel – 5017549 Plate & Caster Assembly, 3" (76mm) casters (2 rigid, 2 swivel with brake); overall height increases by 5” (127mm) DC250 or DC350 White epoxy coated – 5017542 Stainless Steel – 5017544 DC400 or DC750 White epoxy coated – 5017543 Stainless Steel – 5017545 Caster Assembly  DC250 or DC350 – 5012693 3" (76mm) casters (4 swivel; 2 with brake); overall height increases by 4.3" (109mm)  DC750 – 5018646 5" (127mm) casters (4 swivel; 2 with brake); overall height increases by 6.5" (165mm) Cart, 34-1/2" (876mm) H x 24" (610mm) W x 26" (660mm) D DC150, DC250, DC400 – 5018614 Blue epoxy coated without manual door lock (standard) Blue epoxy coated with manual door lock (optional) Stainless Steel without manual door lock (optional) Stainless Steel with manual door lock (optional) Seismic Mounting Brackets (special installation requirements apply) 1014403 overall width increases 2" (48mm) Stacking Kits (it is recommended that fluid warming units be placed at or near the bottom of the stacked configuration whenever possible for maximum stability.) DC250 or DC350 double stacked White epoxy coated – 5013021 Stainless Steel – 5017272 DC400 or DC750 double stacked White epoxy coated – 5013024 Stainless Steel – 5017273 DC250 or DC350 triple stacked White epoxy coated – 5017537 Stainless Steel – 5017539 Stainless Steel Exterior Available with original order only. Timer Control Optional timer allows the user to program the warmer to automatically turn on and off at a selected time. Available with original order only. Timer Control Cart shown with DC150 printed in u.s.a. s pec ific a tio ns a re subj e c t t o c h a n g e w i t h o ut n o t i c e ES3100 (08/15) Designer Series Blanket Warming Cabinet DC150 9.2" (235mm) IEC Cord Inlet Dimensions (HxWxD) 39.1" (994mm) Cord length: 6 ft (1.83m) (est.) With feet (standard): 17.0" x 18.5" x 22.7" (431mm x 470mm x 577mm) With casters (optional): 20.5" x 18.5" x 22.7" (521mm x 470mm x 577mm) Capacity 1.5 ft3 Weight** (est.) NET 18.0" (456mm) Electrical 56 lbs (25 kg) SHIP, CRATED 120 V.A.C. — 60 Hz, 1 ph 0.6 kW, 5.0 Amps Safety Class I Equipment No Applied Parts Mode of Operation: Continuous 36.0" (914mm) 22.7" (577mm) 19.8" (504mm) 18.5" (470mm) 118 lbs (54 kg) NEMA 5-15P 15A - 125V Plug Hospital Grade IPX-0 220 V.A.C. — 50 Hz, 1 ph 0.6 kW, 2.7 Amps CEE 7/7* 220-230V Plug 230 V.A.C. — 50 Hz, 1 ph 0.6 kW, 2.6 Amps BS 1363 Plug* (UK only) IPX-0 14.5" (368mm) CAVITY 15.5" (394mm) CAVITY 13.5" (344mm) IEC Cord Inlet 9.6" (245mm) INSERT 14.4" (366mm) INSERT 10.1" (258mm) CAVITY 16.2" (412mm) 17.0" (431mm) Type B Equipment Type B Equipment CEE 7/7* 220-230V Plug 18.8" (477mm) 17.7" (450mm) IPX-0 *Other international plugs are available. Contact factory for more information. **Domestic ground shipping information. Contact factory for export weight and dimensions. DC250 Dimensions (HxWxD) 9.3" (235mm) IEC Cord Inlet 18.0" (457mm) 42.2" (1071mm) CORD LENGTH: 6 ft (1.83m) (est.) With feet (standard): 21.9" x 18.5" x 25.7" (557mm x 470mm x 653mm) With plate and casters (optional): With bumper and casters (optional): 26.2" x 18.5" x 25.7" (666mm x 470mm x 653mm) With casters (optional): 25.5" x 18.5" x 25.7" (647mm x 470mm x 653mm) Capacity 2.5 ft3 Weight** (est.) NET Electrical 36.0" (914mm) 15.5" (394mm) CAVITY 18.6" (472mm) CAVITY 22.1" (561mm) 18.5" (470mm) IEC Cord Inlet CAVITY INSERT 15.1" (385mm) INSERT 22.8" (580mm) 14.6" (372mm) 21.2" (538mm) 21.9" (557mm) 14.5" (369mm) 67 lbs (30 kg) 120 V.A.C. — 60 Hz, 1 ph 0.6 kW, 5.0 Amps SHIP, CRATED Safety Class I Equipment No Applied Parts Mode of Operation: Continuous 25.7" (653mm) 18.5" (470mm) 26.3" x 21.3" x 25.9" (667mm x 540mm x 657mm) 135 lbs (62 kg) NEMA 5-15P 15A - 125V Plug Hospital Grade IPX-0 220 V.A.C. — 50 Hz, 1 ph 0.6 kW, 2.7 Amps CEE 7/7* 220-230V Plug 230 V.A.C. — 50 Hz, 1 ph 0.6 kW, 2.6 Amps BS 1363 Plug* (UK only) IPX-0 Type B Equipment Type B Equipment CEE 7/7* 220-230V Plug IPX-0 *Other international plugs are available. Contact factory for more information. **Domestic ground shipping information. Contact factory for export weight and dimensions. *Other international plugs are available. Contact factory for more information. **Domestic ground shipping information. Contact factory for export weight and dimensions. DC350 9.3" (235mm) IEC Cord Inlet Dimensions (HxWxD) 18.0" (457mm) 42.3" (1073mm) Cord length: 6 ft (1.83m) (est.) With feet (standard): 27.9" x 18.5" x 25.7" (709mm x 470mm x 653mm) With plate and casters (optional): With bumper and casters (optional): 32.2" x 18.5" x 25.7" (819mm x 470mm x 653mm) With casters (optional): 31.5" x 18.5" x 25.7" (799mm x 470mm x 653mm) Capacity 3.5 ft3 Weight** (est.) NET Electrical 36.0" (914mm) 18.5" (470mm) CAVITY 15.5" (394mm) 120 V.A.C. — 60 Hz, 1 ph 0.8 kW, 6.7 Amps SHIP, CRATED 143 lbs (65 kg) NEMA 5-15P 15A - 125V Plug Hospital Grade IPX-0 220 V.A.C. — 50 Hz, 1 ph 0.8 kW, 3.6 Amps CEE 7/7* 220-230V Plug 230 V.A.C. — 50 Hz, 1 ph 0.8 kW, 3.5 Amps BS 1363 Plug* (UK only) Type B Equipment 24.5" (621mm) IEC Cord Inlet CAVITY 9.6" (244mm) INSERT 21.1" (537mm) INSERT 9.6" (244mm) INSERT 27.2" (691mm) 27.9" (709mm) 14.5" (369mm) 91 lbs (41 kg) Safety Class I Equipment No Applied Parts Mode of Operation: Continuous 25.7" (653mm) 22.8" (580mm) 18.5" (470mm) 32.2" x 21.3" x 25.9" (819mm x 540mm x 657mm) Type B Equipment 22.2" (564mm) CEE 7/7* 220-230V Plug CAVITY IPX-0 IPX-0 *Other international plugs are available. Contact factory for more information. **Domestic ground shipping information. Contact factory for export weight and dimensions. DC400 Dimensions (HxWxD) 12" (305mm) IEC Cord Inlet 23.5" (597mm) 50.0" (1270mm) Cord length: 6 ft (1.83m) (est.) 21.0" (533mm) CAVITY 21" (533mm) CAVITY 24.3" (618mm) 18.5" (470mm) IEC Cord Inlet 14.6" (372mm) INSERT 25.1" (638mm) 15.1" (384mm) CAVITY 21.1" (537mm) 21.9" (557mm) INSERT 26.1" x 24" x 28" (664mm x 610mm x 712mm) With casters (optional): 25.5" x 24" x 28" (647mm x 610mm x 712mm) 26.2" x 26.8" x 28.9" (665mm x 679mm x 734mm) Capacity 4.0 ft3 Weight** (est.) NET 85-1/2 lbs (39 kg) 120 V.A.C. — 60 Hz, 1 ph 0.8 kW, 6.7 Amps Safety Class I Equipment No Applied Parts Mode of Operation: Continuous 28.0" (712mm) 20" (507mm) 21.9" x 24" x 28" (557mm x 610mm x 712mm) With plate and casters (optional): With bumper and casters (optional): Electrical 47.0" (1194mm) 24.0" (610mm) With feet (standard): SHIP, CRATED 165 lbs (75 kg) NEMA 5-15P 15A - 125V Plug Hospital Grade IPX-0 220 V.A.C. — 50 Hz, 1 ph 0.8 kW, 3.6 Amps CEE 7/7* 220-230V Plug 230 V.A.C. — 50 Hz, 1 ph 0.8 kW, 3.5 Amps BS 1363 Plug* (UK only) Type B Equipment Type B Equipment CEE 7/7* 220-230V Plug IPX-0 IPX-0 *Other international plugs are available. Contact factory for more information. **Domestic ground shipping information. Contact factory for export weight and dimensions. *Other international plugs are available. Contact factory for more information. **Domestic ground shipping information. Contact factory for export weight and dimensions. printed in u.s.a. s pec ific a tio ns a r e subj e c t t o c h a n g e w i t h o ut n o t i c e ES3100 (08/15) DC750 Dimensions (HxWxD) 12.0" (305mm) IEC Cord Inlet 35.4" x 24.0" x 28.0" (900mm x 610mm x 710mm) With plate and casters (optional): With bumper and casters (optional): 39.3" x 24.0" x 28.0" (997mm x 610mm x 710mm) INSERT 21.0" (533mm) CAVITY CAVITY 31.8" (807mm) IEC Cord Inlet 21.0" (533mm) 28.1" (715mm) 19.9" (506mm) 13.2" (336mm) INSERT 34.3" (871mm) 13.1" (333mm) INSERT 25.1" (637mm) CAVITY 40.7" x 24.0" x 28.0" (1033mm x 610mm x 710mm) 7.5 ft3 Weight** (est.) NET 134 lbs (61 kg) 120 V.A.C. — 60 Hz, 1 ph 0.8 kW, 6.7 Amps Safety Class I Equipment No Applied Parts Mode of Operation: Continuous 28.0" (710mm) 24.0" (610mm) 39.3" x 26.8" x 28.0" (997mm x 679mm x 710mm) Capacity Electrical 47.0" (1194mm) 35.4" (900mm) With feet (standard): With casters (optional): 23.5" (597mm) 50.0" (1270mm) Cord length: 6 ft (1.83m) (est.) SHIP, CRATED 219 lbs (99 kg) NEMA 5-15P 15A - 125V Plug Hospital Grade IPX-0 220 V.A.C. — 50 Hz, 1 ph 0.8 kW, 3.6 Amps CEE 7/7* 220-230V Plug 230 V.A.C. — 50 Hz, 1 ph 0.8 kW, 3.5 Amps BS 1363 Plug* (UK only) Type B Equipment Type B Equipment CEE 7/7* 220-230V Plug 24.2" (614mm) IPX-0 IPX-0 *Other international plugs are available. Contact factory for more information. **Domestic ground shipping information. Contact factory for export weight and dimensions. ENTHERMICS MEDICAL SYSTEMS An ISO 13485:2003 certified company PO Box 443, Menomonee Falls WI 53052-0443 W164 N9221 Water St, Menomonee Falls WI 53051 Tel 262-251-8356 | 800-TO-B-WARM [email protected] www.enthermics.com PRINTED IN U.S.A. specifications are subJect to change without notice MADE IN THE U.S.A. ES3100 (08/15)