Preview only show first 10 pages with watermark. For full document please download

Dc/dc Converter

   EMBED


Share

Transcript

4:1 WIDE INPUT 3WTT DC/DC CONVERTER PD4W30...D-M(A/B/C)D KEY FEATURES * 4:1 wide input voltage * High I/O isolation voltage * MOSFET design * Single and dual outputs * Input filter * 50KHz Min. switching frequency * Compatible to other manufacturers' products APPLICATIONS * Telecommunications / Lan * Industrial machines ELECTRICAL SPECIFICATIONS PIN ASSIGNMENT INPUT * Input range ----------- 9 ~ 36 VDC, 24 VDC nominal 18 ~ 72 VDC, 48 VDC nominal * Input filter ------------ Pi-network OUTPUT * Output voltage accuracy --- +/- 2% Max. * Line regulation (HL - LL) --- +/- 0.5% Max. * Load regulation (1/10L - FL) --- +/- 0.2% Max. * Ripple and noise, 20MHz bandwidth --- 100mVp-p Max. * Temperature coefficient --- +/-0.03%/ C * Short circuit protection --- Continuous GENERAL * Operating frequency ----- 50KHz Min. * I/O isolation voltage ----- 1000 VDC * I/O capacitance ----------- 80 pF * I/O resistance ------------- 1G ohms Min. * Efficiency ----------------- 70% Min. * Weight---------------------- 14.6g * Case Size------------------- 1.25*0.80*0.48 inch ENVIRONMENTAL ORDERING INFORMATION * Operating temperature range ------- -25 ~ +70 C * Storage temperature range ---------------------- -40 ~ +100 C * Cooling ------------------- Free air convection All specifications typical at nominal line, full load, and 25 C unless otherwise noted. PUT POWERTECH, INC. 35 PD 4W 30 S 48 05 D - M AD Output voltage Input voltage S =Single output D =Dual Power rating : 3W 4:1 wide input range Isolation D= 1,000VDC DC/DC converter TEL : 886-2-22181510 FAX : 886-2-22181512 WEB: www.putpowertech.com Case type A=Case A B=Case B C=Case C D=DIL Case material M = Metal E-MAIL : [email protected] 4:1 WIDE INPUT 3WATT INPUT / OUTPUT SPECIFICATION Input Current (mA) TYPE PDXW Input Voltage(VDC) No load PD4W30S2405D-M(A/B/C)D 9 ~ 36 18 338 Output Voltage(VDC) 5 PD4W30S2409D-M(A/B/C)D 9 ~ 36 18 316 9 330 PD4W30S2412D-M(A/B/C)D 9 ~ 36 18 313 12 250 PD4W30S2415D-M(A/B/C)D 9 ~ 36 18 313 PD4W30D2405D-M(A/B/C)D 9 ~ 36 18 338 PD4W30D2412D-M(A/B/C)D 9 ~ 36 18 316 15 +5 + 12 200 + 300 + 125 PD4W30D2415D-M(A/B/C)D 9 ~ 36 18 316 + 15 + 100 PD4W30S4805D-M(A/B/C)D 18 ~ 72 10 167 5 600 PD4W30S4809D-M(A/B/C)D 18 ~ 72 10 158 9 330 PD4W30S4812D-M(A/B/C)D 18 ~ 72 10 156 12 250 PD4W30S4815D-M(A/B/C)D 18 ~ 72 10 156 PD4W30D4805D-M(A/B/C)D 18 ~ 72 10 167 PD4W30D4812D-M(A/B/C)D 18 ~ 72 10 156 15 +5 + 12 200 + 300 + 125 PD4W30D4815D-M(A/B/C)D 18 ~ 72 10 156 + 15 Full load Output Current (mA) 600 + 100 NOTES: * Specifications are for convection rating unless otherwise stated. * Detailed engineering specification of each model is available for inquiry. * Specifications subject to change without notice. MECHANICAL DRAWING PUT POWERTECH, INC. TEL : 886-2-22181510 FAX : 886-2-22181512 WEB: www.putpowertech.com E-MAIL : [email protected] 36