Preview only show first 10 pages with watermark. For full document please download

De Relays (ade)

   EMBED


Share

Transcript

Produkt dostpny w sklepie www.Soyter.pl <--- kliknij DE (ADE) VDE COMPACT HIGH-INSULATION POLARIZED POWER RELAY FEATURES 12.5 .492 25.0 .984 DE RELAYS (ADE) 12.5 .492 mm inch • Conforms to European safety standards (VDE0700 and VDE0631) Insulating distance between coil and contacts: Clearance Min. 8mm .315 inch Creepage distance Min. 8mm .315 inch • Extensive product line-up • Surge voltage between contact and coil 12 kV • Low operating power Nominal operating power at 200 mW (Single side stable, 2 coil latching) • Compact body saves space Size: 12.5(W)  25.0(L)  12.5(H) mm .492(W)  .984(L)  .492(H) inch • UL/CSA, VDE approved SPECIFICATIONS Contact Arrangement Characteristics 1 Form A 1 Form A 1 Form B AgSnO2 type 2 Form A Contact material Initial contact resistance, max. (By voltage 30m drop 6V DC 1A) Nominal 10A 250V AC, 8A 250V AC, 8A 250V AC, switching 10A 30V DC 8A 30V DC 8A 30V DC capacity Max. 2,500 VA*, 2,000 VA*, 2,000 VA*, switching 300W 240W 240W power Rating Max. 440V AC, 440V AC, 440V AC, (resistive switching 230V DC 230V DC 230V DC load) voltage Max. switching 10A (16A)* 8A (16A)* 8A (16A)* current Min. switching capac100 mA, 5 V DC ity#1 Mechanical (at 300cpm) Electrical Expected (at 20 cpm) life (min. (resistive load) operations) Electrical (16A / 230 V AC resistive)* Max. operating speed Initial insulation resistance*1 Between open contacts Initial breakdown voltage*2 Between contact sets Between contact and coil Surge voltage between contact and coil*3 Operate time [Set time]*4 Release time (without diode) [Reset time]*4 Temperature rise (at 70C)*5 Shock resistance Functional*8 Vibration resistance Destructive 107 105(AC) 5  104(DC) 10 5 25000 Functional*6 Destructive*7 20000 Conditions for operation, transport and storage*9 (Not freezing and condensing at low temperature) Unit weight Ambient temp. Humidity 20 cpm (at rated load) Min. 1,000 M (at 500 V DC) 1,000 Vrms 4,000 Vrms (2 Form A, 1 Form A 1 Form B) 5,000 Vrms Min. 12,000 V (initial) Max. 10ms (typ. 5ms) [Max. 10ms (typ. 4ms)] (at 20C 68F) Max. 5ms (typ. 2ms) [Max. 10ms (typ. 4ms)] (at 20C 68F) Max. 50C Min. 196 m/s2{20 G} Min. 980 m/s2{100 G} 10 to 55 Hz at double amplitude of 2 mm 10 to 55 Hz at double amplitude of 3 mm –40C to 70C –40F to 158F 5 to 85% R.H. Approx. 7 g .25 oz Coil (at 20C, 68F) Nominal operating power 200 mW 100 mW 200 mW Single side stable 1 coil latching 2 coil latching #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. Remarks * *1 *2 *3 *4 *5 *6 *7 *8 *9 16A possible for one contact set only with max. 4000 VA switching power. Measurement at same location as “Initial breakdown voltage” section. Detection current: 10mA Wave is standard shock voltage of 1.2  50s according to JEC-212-1981 Nominal operating voltage applied to the coil, excluding contact bounce time. By resistive method Half-wave pulse of sine wave: 11ms, detection time: 10ms. Half-wave pulse of sine wave: 6ms Detection time: 10ms Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information. ds_61A01_en_de: 100811D Produkt dostpny w sklepie www.Soyter.pl <--- kliknij 1 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij DE (ADE) TYPICAL APPLICATIONS ORDERING INFORMATION Ex. • Temperature controller • Automatic meter reading • OA equipment • FA equipment Product name DE DE 1a L Contact arrangement 1a: 1 Form A 1a1b: 1 Form A 1 Form B 2a: 2 Form A 3 Operating function Nil: Single side stable L: 1 coil latching L2: 2 coil latching Notes: 1) Standard packing; Carton (tube package) 20 pcs. Case 500 pcs. V Coil voltage, V DC 1.5, 3, 4.5, 5, 6, 9, 12, 24, 48** **just for single side stable 2) UL/CSA, VDE approved type is standard. TYPES AND COIL DATA (at 20C 68F) • Single side stable type 1 Form A, 1 Form A 1 Form B, 2 Form A Part No. 1.5 3 4.5 5 6 9 12 24 48 Pick-up voltage, V DC (max.) (initial) 1.05 2.1 3.15 3.5 4.2 6.3 8.4 16.8 33.6 Nominal voltage, V DC Set voltage, V DC (max.) (initial) 1.5 3 4.5 5 6 1.05 2.1 3.15 3.5 4.2 Reset voltage, V DC (min.) (initial) 1.05 2.1 3.15 3.5 4.2 9 12 24 6.3 8.4 16.8 6.3 8.4 16.8 812 1,440 5,760 Nominal voltage, V DC Set voltage, V DC (max.) (initial) Reset voltage, V DC (min.) (initial) Coil resistance,  (10%) 1.5 3 4.5 5 6 9 12 24 1.05 2.1 3.15 3.5 4.2 6.3 8.4 16.8 1.05 2.1 3.15 3.5 4.2 6.3 8.4 16.8 Nominal voltage, V DC DE-1.5V DE-3V DE-4.5V DE-5V DE-6V DE-9V DE-12V DE-24V DE-48V Drop-out voltage, V DC (min.) (initial) 0.15 0.3 0.45 0.5 0.6 0.9 1.2 2.4 4.8 Max. allowable voltage, V DC 1.95 3.9 5.85 6.5 7.8 11.7 15.6 31.2 62.4 Coil resistance,  (10%) Nominal operating current, mA (10%) Nominal operating power, mW 11.3 45 101 125 180 405 720 2,880 11,520 132.7 66.6 44.5 40 33.3 22.2 16.6 8.3 4.2 200 200 200 200 200 200 200 200 200 Coil resistance,  (10%) Nominal operating current, mA (10%) Nominal operating power, mW 22.5 90 202 250 360 66.6 33.3 22.3 20 16.7 100 100 100 100 100 Max. allowable voltage, V DC 1.95 3.9 5.85 6.5 7.8 11.1 8.3 4.2 100 100 100 11.7 15.6 31.2 Nominal operating current, mA (10%) Set coil Reset coil 66.6 66.6 66.6 66.6 44.5 44.5 40 40 33.3 33.3 22.2 22.2 16.6 16.6 8.3 8.3 Nominal operating power, mW Set coil Reset coil 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 Max. allowable voltage, V DC • 1 coil latching type 1 Form A Part No. DE-L-1.5V DE-L-3V DE-L-4.5V DE-L-5V DE-L-6V DE-L-9V DE-L-12V DE-L-24V • 2 coil latching type 1 Form A Part No. DE-L2-1.5V DE-L2-3V DE-L2-4.5V DE-L2-5V DE-L2-6V DE-L2-9V DE-L2-12V DE-L2-24V Set coil 11.3 45 101 125 180 405 720 2,880 Reset coil 11.3 45 101 125 180 405 720 2,880 1.95 3.9 5.85 6.5 7.8 11.7 15.6 31.2 Note: Insert contact arrangement, e.g.1a, 1a1b, 2a, in  for contact form required. 2 ds_61A01_en_de: 100811D Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Produkt dostpny w sklepie www.Soyter.pl <--- kliknij DE (ADE) DIMENSIONS(mm inch) CAD Data Data from our Web site. Download CAD PC board pattern (Bottom view) Single side stable 2 coil latching type 1 coil latching type Single side stable 1 coil latching type CAD Data 25.0 .984 12.5 .492 12.0 .472 15.24 .600 7.62 .300 7.62 .300 0.8 .032 15.24 .600 7.62 .300 0.8 .032 1.0 .039 2.44 .096 12.70 .500 8-1.2 dia 8-.047 dia 7.62 .300 7.62 .300 0.4 .016 7.62 .300 Tolerance : 0.1 .004 Schematic (Bottom view) Single side stable (1 Form A) 2 coil latching type 25.0 .984 1 3 4 8 6 5 (1 Form A 1 Form B) (2 Form A) 1 3 4 1 3 4 8 6 5 8 6 5 12.5 .492 12.0 .472 2.54 .100 2.54 .100 3.5 .138 0.5 .020 0.5 dia .020 dia 0.5 .020 0.5 dia .020 dia 6-1.2 dia 6-.047 dia (5,6: dummy terminal) (Deenergized condition) (1 Form A) (1 Form A 1 Form B) 1coil latching type 3.5 .138 0.5 dia .020 dia 12.70 .500 0.8 .032 7.62 .300 0.8 .032 1.0 .039 2.44 .096 0.4 .016 7.62 .300 (2 Form A) 1 3 4 1 3 4 1 3 4 8 6 5 8 6 5 8 6 5 (5,6: dummy terminal) (Reset condition) (1 Form A) (1 Form A 1 Form B) 2coil latching type Tolerance: 0.3 .012 (2 Form A) 1 2 3 4 1 2 3 4 1 2 3 4 8 7 6 5 8 7 6 5 8 7 6 5 (5,6: dummy terminal) (Reset condition) ds_61A01_en_de: 100811D Produkt dostpny w sklepie www.Soyter.pl <--- kliknij 3 Produkt dostpny w sklepie www.Soyter.pl <--- kliknij DE (ADE) REFERENCE DATA 2. Life curve Current, A Contact load, A 1. Max. switching power Contact voltage No. of operations 3.-(1) Coil temperature rise (1 Form A) 3.-(2) Coil temperature rise (1 Form A 1 Form B) 3.-(3) Coil temperature rise (2 Form A) Tested sample: ADE109 Quantity: n=6 Ambient temperature: 25C to 70C 77F to 158F Tested sample: ADE309 Quantity: n=6 Ambient temperature: 25C to 70C 77F to 158F Tested sample: ADE209 Quantity: n=6 Ambient temperature: 25C to 70C 77F to 158F 50 10A 0A 10A 0A 30 20 40 8A 0A 8A 30 0A 20 10 10 0 Temperature rise, °C 40 50 25°C 77°F 70°C 158°F 25°C 77°F 70°C 158°F Temperature rise, °C Temperature rise, °C 50 70 80 90 100 110 120 Coil applied voltage, %V 0 130 25°C 77°F 70°C 158°F 8A 40 8A 0A 0A 30 20 10 70 80 0 90 100 110 120 130 Coil applied voltage, %V 70 80 90 100 110 120 130 Coil applied voltage, %V 4-1. Operate/release time (1 Form A) 4-2. Operate/release time (1 Form A 1 Form B) 4-3. Operate/release time (2 Form A) Tested sample: DE1a-5V Quantity: n=5 Tested sample: DE1a1b-5V, Quantity: n=5 Tested sample: DE2a-5V, Quantity: n=5 40 10A 0A 10A 0A 30 20 8 Release time (With diode) 6 Max. x Min. 5 4 3 Max. x Min. Max. x Min. Operate time 2 Release time 1 70 80 90 100 110 120 Coil applied voltage, %V 130 7 Operate time 6 Max. x Max. Min. x Min. 5 4 3 Release time (With diode) 2 10 0 Operate/release time, ms 7 25°C 77°F 70°C 158°F Operate/release time, ms Temperature rise, °C 50 0 70 80 90 100 Max. x Min. 1 110 120 130 0 Release time 70 80 90 100 110 120 130 Coil applied voltage, %V Coil applied voltage, %V Tested sample: DE1a-5V, Ambient temperature: –40C to 80C –40F to 176F, Quantity: n=6 Tested sample: DE1a1b-5V, Ambient temperature: –40C to 80C –40F to 176F, Quantity: n=6 Tested sample: DE2a-5V, Ambient temperature: –40C to 80C –40F to 176F, Quantity: n=6 -40 -40 -20 -4 0 32 -10 -20 -30 4 30 20 Drop-out voltage Pick-up voltage 10 0 20 40 68 104 60 140 80 176 -40 -40 Ambient temperature,°C °F -20 -4 0 32 Rate of change, V% 5-3. Ambient temperature characteristics (2 Form A) Rate of change, V% 5-2. Ambient temperature characteristics (1 Form A 1 Form B) Rate of change, V% 5-1. Ambient temperature characteristics (1 Form A) 30 Drop-out 20 voltage 10 0 Pick-up voltage 20 40 60 80 68 104 140 176 -10 Ambient temperature,°C °F -20 -40 -40 -20 -4 0 32 -10 -20 -30 30 Drop-out 20 voltage Pick-up voltage 10 0 20 40 60 80 68 104 140 176 Ambient temperature,°C °F -30 ds_61A01_en_de: 100811D Produkt dostpny w sklepie www.Soyter.pl <--- kliknij Produkt dostpny w sklepie www.Soyter.pl <--- kliknij DE (ADE) Contact resistance, Ω 6. Change of contact resistance No. of operations SAFETY STANDARDS Item 1 Form A 1 Form A 1 Form B 2 Form A File No. E120782 E120782 E120782 UL/C-UL (Recognized) Contact rating PILOT DUTY B300 R300 PILOT DUTY B300 R300 PILOT DUTY B300 R300 File No. LR85932 LR85932 LR85932 CSA (Certified) Contact rating PILOT DUTY B300 R300 PILOT DUTY B300 R300 PILOT DUTY B300 R300 File No. 115944 VDE (Certified) Contact rating 8A 250V AC (cos=1.0) 115944 8A 250V AC (cos=1.0) 115944 8A 250V AC (cos=1.0) For Cautions for Use, see Relay Technical Information. ds_61A01_en_de: 100811D Produkt dostpny w sklepie www.Soyter.pl <--- kliknij 5